首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 78 毫秒
1.
脑减影CT灌注成像技术初探   总被引:1,自引:1,他引:0  
目的探讨脑减影CT灌注成像(sCTP)技术及其初步应用。方法选取11例有脑CTP源影像的患者,其中脑梗死10例、脑瘤1例,在AW4.2工作站利用减影软件先行减影处理,再以Perfusion3软件对减影图像数据和源影像数据分别作灌注成像分析,测量血流量(BF)、血容量(BV)、平均通过时间(MTT)、毛细血管通透性(PS)数值并生成其色阶图,进行组间、区间比较与分析。结果①脑sCTP技术成功率为100%,均获得了有诊断价值的BF、BV、MTT或PS色阶图及其数值,其后处理时间约需1~2.5h;②sCTP提供的BF、BV、MTT、PS色阶图与CTP的类似,均准确揭示了病变及微循环血液动力学情况;③与CTP类似,脑sCTP提供的BF、BV、MTT、PS数值病变与毗邻及对侧组织有显著性差异(P〈0.025)。结论脑sCTP技术可行,是减影技术结合灌注成像技术的产物,可作为脑卒中、脑肿瘤功能成像诊断的补充和可选择的检查手段。  相似文献   

2.
目的探讨同步与非同步扫描对64层容积CT数字减影血管造影(VCTDSA)图像质量的影响。方法建立紧贴骨结构的血管模型,采用64层螺旋CT进行扫描:①未注射对比剂螺旋扫描20次,球管曝光时间为2.1s,扫描间隔时间分别为1.9s、3.9s、5.9s、7.9s、9.9s、11.9s、13.9s、15.9s、17.9s、19.9s,2.9s、4.9s、6.9s、8.9s、10.9s、3.0s、4.0s、5.0s、6.0s、7.0s。②注射对比剂后螺旋扫描10次,扫描间隔时间分别为9.9s、11.9s、13.9s、15.9s、17.9s,10.9s、12.9s、11.0s、12.0s、13.0s,其余扫描参数同①。减影后数据行3D容积再现(VR)及最大密度投影(MIP)图像重组,评价减影后图像质量、测量减影后全幅图像CT值、记录球管曝光角度差。结果注射对比剂前后同步扫描15次,减影后图像质量均为Ⅰ级,非同步扫描15次,减影后图像质量Ⅰ级2次、Ⅱ级12次、Ⅲ级1次;20次未注射对比剂减影后图像CT值比较,非同步扫描减影后图像CT值均数高于同步扫描;同步扫描的球管曝光角度差均数明显小于非同步扫描。结论同步扫描保证球管曝光的起始位置相同,可明显提高VCTDSA的图像质量。  相似文献   

3.
目的 观察柔性减影CE-Boost技术对CT肺动脉造影(CTPA)图像质量的影响。方法 回顾性分析66例疑诊肺栓塞(PE)患者的肺部CT平扫及CTPA资料,对平扫期和增强动脉期图像进行薄层重建,以Sure-Subtraction Lung软件行柔性减影,获得CE-Boost序列图像。将重建后增强动脉期图像(A组)与CE-Boost图像(B组)上传至Toshiba Vitrea后处理工作站,测量肺动脉及其分支CT值,计算信噪比(SNR)及对比噪声比(CNR);并由2名影像科医师采用5分法对图像质量进行主观评分。结果 B组肺动脉主干,左、右肺动脉干,左、右上肺动脉分支及左、右下肺动脉分支的CT值、SNR值及CNR值均高于A组(P均<0.001)。B组图像主观评分5(4,5)分,高于A组的2(1,2)分(Z=-4.980,P<0.001),且2名医师对A、B组图像质量评分的一致性较高(Kappa=0.896)。结论 柔性减影CE-Boost技术可提高CTPA图像质量。  相似文献   

4.
目的 探讨CT扫描替代肝脏活检病理检查评价脂肪变性的可行性.方法 回顾性分析北京大学人民医院2006-2009年实施的215例原位肝移植患者的临床资料.对肝脏活检病理标本和螺旋CT扫描资料进行再评价.对肝脏CT值、肝/脾CT值比值、肝/降主动脉CT值比值及肝/下腔静脉CT值比值与病理学脂肪变性程度进行相关性分析.结果 215例供肝活检组织标本中52例存在程度不同的脂肪变性,占全部病例的24.2%,脂肪变性程度介于2.78%~ 56.8%,平均为17.00%±13.75%.病理学确认存在脂肪变性肝脏的平均CT值、肝/脾CT值比值、肝/降主动脉CT值比值、肝/下腔静脉CT值比值分别为(41.3±7.5) HU、0.89±0.16、1.02 ±0.16、1.04±0.15,显著低于无脂肪变性者.肝脏脂肪变性程度与肝脏CT值、肝/脾CT值比值、肝/降主动脉CT值比值、肝/下腔静脉CT值比值均呈负相关,相关系数分别为-0.881(P <0.01)、-0.817 (P< 0.05)、-0.951(P <0.001)、-0.948(P <0.001).结论 肝脏的CT值、肝/脾CT值比值、肝/降主动脉CT值比值、肝/下腔静脉CT值比值均可以定量反应肝脏脂肪变性的严重程度,其中以肝/降主动脉CT值比值最为准确.  相似文献   

5.
目的探讨MSCT与DSA对小肠胃肠道间质瘤(GIST)的诊断价值。方法回顾性分析经病理证实的19例小肠GIST患者的MSCT资料及其中6例患者的DSA特征。结果MSCT表现:19例中,病灶位于空肠16例,位于回肠2例,位于空回肠交界处1例;单发17例,多发2例。6例低危GIST肿瘤呈类圆形或椭圆形,边界清;其中4例密度均匀,2例密度不均;瘤内片状低密度及点状钙化各1例。5例中危GIST肿瘤呈分叶状或不规则形,边界欠清,密度不均。8例高危GIST肿瘤呈分叶状、不规则形,与周围组织间分界不清;1例密度均匀,7例密度不均;多发病灶2例,单发6例;4例瘤内可见多发不规则低密度,2例可见局限性低密度区,1例可见点状钙化。低、中、高危险度GIST动脉期瘤体均明显强化,静脉期持续强化。DSA表现:6例病灶内均可见异常血管及肿瘤染色,其中4例肠系膜上动脉1条分支增粗,远段血管分支增多、紊乱,2例肠系膜上动脉2条或3条血管分支增粗,远段见球形包绕征。结论 MSCT可清晰显示肿瘤的大小、形态、密度、边缘及强化情况,可为小肠GIST危险程度的预判提供有价值的信息;DSA可精确定位、定量肿瘤供血动脉,客观显示肿瘤的血供变化。  相似文献   

6.
目的评价基于大螺距原始投影数据的图像质量增强重建(IQE)技术的图像质量。方法①采集头颅标本原始数据,分别以传统方式和IQE方式进行重建并评价图像伪影。②选择60例于16排CT接受头颅检查患者,其中30例采用螺距1∶1.75,另30例采用螺距1∶1.375,管电压及管电流均为120kVp、200 mAs,重建层厚和重建间隔均为0.625mm。对1∶1.75螺距采样原始数据分别采用常规技术和IQE技术进行重建,评价不同螺距、不同重建方式图像质量的差异,并获取图像噪声标准差(SD)值进行定量分析。结果①头颅模型数据显示,采用IQE重建较传统重建图像中的风车状伪影明显减少。②临床图像数据显示,螺距为1∶1.75时,采用IQE重建图像的伪影明显少于传统技术重建图像;IQE图像质量优于传统重建(P0.05)。传统重建技术和IQE重建图像的SD值分别为27.42±3.70和20.11±4.20(t=4.913,P0.05)。结论采用IQE技术进行大螺距扫描可获得满意的图像质量,并降低图像噪声。  相似文献   

7.
目的:研究螺旋CT胰腺期、肝脏期双期增强薄层扫描在小胰腺癌早期诊断中的作用.方法:对25例小胰腺癌患者行螺旋CT双期增强扫描,扫描延迟时间分别为38s和70s,胰腺期行2mm层厚,螺距1.0扫描,并对胰腺期扫描分别以2mm间隔及5mm层厚和5mm间隔重建.对1cm<病灶<2cm和病灶<1cm在2mm层厚图象与5mm层厚重建图像上显示情况进行对比观察研究,并对术前预测和术后进行对比.结果:两组观察结果经统计学处理检出率有显著性差异:对1cm<病灶<2cm检出率p<0.01,对病灶<1cm检出率p<0.025;术前预测可切除性和不能切除和术后进行对比没有明显差异P>0.1.结论:螺旋CT动态增强薄层扫描可明显提高小胰腺癌和微胰腺癌的检出率,对小胰腺癌的早期诊断有重要的临床价值.肝脏期扫描为临床确定肿瘤是否能够手术切除提供科学依据.  相似文献   

8.
多层螺旋CT肝脏动脉期增强扫描多采用固定延迟扫描时间法,也有采用自动跟踪触发技术者,本文通过对两种方法的对照研究,探讨自动跟踪触发技术在多层螺旋CT肝脏动脉期最佳扫描时间的作用。  相似文献   

9.
目的探讨示踪减影透视(TSF)在颅内动脉瘤介入治疗中的临床应用价值。方法 11例接受介入栓塞治疗的颅内动脉瘤患者,术前均接受双源CT血管成像(DSCTA)及全脑数字减影血管造影(DSA)检查,确定动脉瘤的大小、形态、位置,并测量瘤颈及瘤体的直径;术中应用TSF技术。结果 11例患者(共11个动脉瘤)介入栓塞均获得成功,共植入电解可脱弹簧圈39枚,包括1枚3-D标准成篮填充弹簧圈,3枚3-D软成篮填充弹簧圈及35枚柔软型填充弹簧圈。结论对接受颅内动脉瘤介入栓塞治疗的患者,术中应用TSF可提高治疗效果。  相似文献   

10.
目的对比CT增强和非刚性三维校正肝脏MR增强动态减影技术对肝细胞癌(HCC)经导管动脉内化疗栓塞术(TACE)后肿瘤血供判断能力的差异,探讨非刚性三维校正肝脏MR增强动态减影技术的临床应用价值。 方法收集HCC患者TACE术后并再次需进行TACE治疗的病例21例,所有患者均行CT平扫及增强扫描、MR平扫及动态增强扫描,MR扫描采用非刚性三维校正动态减影技术。分别在CT和MR增强非刚性三维校正减影图像上对病灶血供情况评估统计,以再次TACE术前的DSA评价结合结节前后的体积变化综合考虑作为金标准,比较两种检查方式对碘油沉积病灶血供评价的能力。 结果共分析126个碘油沉积灶,在对碘油沉积灶血供的判断中,CT与DSA检查诊断结果不一致(P<0.001),MR和DSA检查诊断结果一致(P=0.375);在结节的血供判断方面,CT/MR对肝结节血供判断的敏感度、特异度、假阳性率、假阴性率、正确指数、阳性似然比、阴性似然比、符合率分别为6.2%/99.1%、76.0%/69.2%、23.1%/30.8%、93.8%/0.9%、0.02/0.68、0.27/3.22、1.22/0.01、13.5%/96.0%。 结论相对CT检查,非刚性三维校正肝脏MR动态减影技术在HCC患者TACE治疗后疗效评估中有明显的诊断优势,具有重要的临床应用价值。  相似文献   

11.
MSCT常规腹部多期增强去骨血管 成像技术的临床应用   总被引:1,自引:0,他引:1  
目的利用编辑减影去骨技术对MSCT常规腹部多期增强扫描数据进行快速血管成像,探讨其临床应用价值。方法选择临床怀疑非血管性病变而接受常规腹部多期增强扫描的患者123例,进行减影去骨快速血管成像,并与常规轴位像比较,部分患者同时与DSA结果进行对照。结果与常规增强轴位图相比:去骨MSCTA技术发现动脉瘤27例,狭窄与细小血管55支,变异血管37支;门静脉栓塞12例(常规轴位图诊断出11例)、动静脉瘘6例(常规轴位图诊断出5例)、静脉曲张12例(常规轴位图诊断出8例);另有27例可清晰显示肿瘤供血血管,与DSA比较,去骨MSCTA对上述病变及肿瘤供血血管总检出率达94.59%。结论利用MSCT常规腹部多期增强扫描数据,进行编辑去骨血管成像能快速清晰显示腹部血管,为血管病变提供更多有价值的信息,值得临床推广。  相似文献   

12.
Objective: Detection of abdominal in- jury is a very important component in trauma management, so a precise assessment of liver and spleen injuries includ- ing their severity degree is necessary. There is a good case to believe that in emergency situations the radiologists' performance may profit from a systematic approach using established scoring systems. Score systems as the organ injury scale (OIS) drawn up by the American Association for the Surgery of Trauma are a valuable guidance for objec- tive trauma assessment. Aim of this study was to evaluate retrospectively whether a structured approach using the OIS may help improve trauma assessment. Methods: Fifty-three patients, 38 male and 15 female who underwent CT and laparotomy after abdominal trauma were included in this study. The laparotomy was performed by experienced surgeons with a minimum experience of 6 years. While the original CT reports were written by differ- ent radiologists with a minimum experience of 3 years, and then a radiologist with experience of 4 years reviewed the same original CT pictures, resulting in the structured report. Both the original and structured CT results on liver and spleen injuries were transferred into OIS grades. Finally, the initial and structured CT results were compared with theintraoperative findings gathered from the surgery report. Results: Regarding the original CT report we found a mean divergence of 0.68±0.8 (r=-0.45) to the OIS finding in the surgery report for liver injuries (0.69±1.17 for spleen injuries; r=-0.69). In comparison with the structured approach, where we detected a divergence of 0.8±0.68; r=-0.63 (0.47±0.77 for spleen injuries; r=0.91), there was no significant difference. However we detected a lower rate of over-diag- nosis in structured approaches. Conclusion: Our study shows that a structured ap- proach to triage abdominal trauma using an imaging check- list does not lead to a significantly higher detection rate, but a nonsignificant trend to reduce the rate of over- diagnoses, thus being more precise in grading the severity grade. Concerning the bias by retrospective study design, further prospective investigations are needed to evaluate the impact of trauma scores on the workflow in emergency department procedure as structured reporting systems are a valuable guidance in other radiological disciplines.  相似文献   

13.
目的 探讨肝移植术前超声和螺旋CT门静脉成像(SCTP)检查对诊断门静脉栓塞的准确率.方法 135例肝移植受者在术前分别接受了超声、SCTP以及超声联合SCTP检查,对其中31例怀疑有门静脉栓塞的受者同时进行了超声造影检查,并对受者的门静脉栓塞情况及栓子性质进行初步诊断;以肝移植术中和术后病肝的解剖和组织病理学检查为门静脉栓塞和栓子性质的诊断标准.将肝移植术前经各项检查得出的门静脉栓塞例数及栓子性质的诊断结果与术中和术后的诊断标准进行对比分析,评估术前各项检查的诊断准确率.结果 超声检查对诊断门静脉栓塞的准确率为91.1%(123/135),SCTP检查为86.7%(117/135),超声和SCTP联合检查为95.6%(129/135),联合检查显著高于单一检查(P<0.05).超声造影对门静脉内栓子的定性诊断的准确率为100 %,显著高于超声检查(58.6%)和SCTP检查(73.9%,P<0.05).结论 肝移植术前超声和SCTP检查对诊断门静脉栓塞均有较高的准确率,两者联合检查的准确率更高;超声造影可明确门静脉内栓子的性质.  相似文献   

14.
目的探讨多层CT(multi—sliceCT,MSCT)在活体肝移植术前供肝体积测量中应用价值。方法11例活体肝移植病例术前均实施MSCT扫描,对MSCT图像进行图像后处理,对不同后处理方法测量肝脏体积的准确性及便利性进行比较。结果11例患者中,与图像重建层厚Vitrea0.5mm描绘法比较,以Vitrea5mm和10mm以及安科公司的ViewerPACS数字图像系统10mm层厚描绘法测量的全肝脏体积以及右半肝体积没有统计学差异。结论MSCT可作为术前评估肝脏体积的可靠检查方法,Vitrea10mm描绘法极大地简化了肝脏体积测量的过程。  相似文献   

15.
减影CTA阈值调节法测量脑血管径线   总被引:1,自引:0,他引:1  
目的评价减影CTA中采用阈值调节法测量脑血管径线的准确性。方法收集接受脑血管CTA检查的患者60例,采用阈值调节法测量并比较常规CTA和减影CTA中双侧大脑前动脉、大脑中动脉、颈内动脉的血管径线差异。结果根据常规CTA血管内CT值标化阈值后,减影CTA所测各段血管径线均小于常规CTA测值(P均0.05);分别根据各自图像中血管内CT值标化阈值后,常规CTA和减影CTA所测各段血管径线差异均无统计学意义(P均0.05)。结论减影CTA中采用阈值测量法测量血管径线准确、可靠,具有一定临床应用价值。  相似文献   

16.
目的 探讨多层螺旋CT(MSCT)半自动法测量右半供肝体积的准确性,及该方法在活体肝移植(LDLT)中的应用价值.方法 对56例供者术前行MSCT四期增强扫描,然后分别根据MSCT图像手动绘图(简称:手动法)计算右半供肝体积(V手)和应用IQQA(R)-liver肝脏诊断辅助分析系统进行半自动化绘图(简称:半自动法)计算右半供肝体积(V半),将两种方法计算的右半供肝体积与术中经水置换法实测的右半供肝体积(V术)进行相关分析和Bland-Altman检查,得出其线性回归方程.结果 V半、V手和V术分别为(818.60±161.43)、(880.16±169.92)和(669.84±141.37)cm3;半自动法和手动法测量供肝体积与术中实测肝体积均显著相关(r值分别为0.778和0.746,P<0.05),其线性回归方程分别为V术=V半×0.681+112.26,V术=V手×0.620+123.81.半自动法测量肝体积与术中实测肝体积的差值为148.76cm3,95%可信区间为121.57~175.95 cm3,吻合限为-354.135~56.62 cm3,手动法测量肝体积与术中实测肝体积的差值为210.33 cm3,95%可信区间为180.09~240.56 cm3,吻合限为-438.66~18.01cm3.结论 半自动法测量LDLT右半供肝体积比目前最常用的手动法更为准确.
Abstract:
Objective To evaluate the accuracy of multi-detector spiral CT (MSCT) semiautomated volumetric measurement of right lobes and its value in living donor liver transplantation (LDLT). Methods Fifty-six donors underwent four phases MSCT. Pre-operative liver volumes of two measurements [IQQA(R)-liver semi-automated (Vs) and manual volume (Vm) measurements] in portal vein phase were compared with intra-operative measurement (Vio) by means of water displacement. Results Correlation analysis and Bland-Altman tests were used for statistical analysis.Results Pre-operative measurements of grafts resulted in a mean Vs, Vm, Vio of (818. 60 ± 161.43)cm3 , (880. 16 ± 169. 92) cm3 and (669. 84 ± 141.37) cm3 respectively. All corresponding pre-and intra-operative data were correlated significantly with each other. There was a good correlation between Vs and Vio(r= 0. 778, P<0. 05), so did Vm and Vio(r= 0. 746, P<0. 05). The equations of linear regression were Vio = Vs × 0. 681 + 112. 26, and Vio = Vm × 0. 620 + 123. 81 respectively. Exact 95 % CIs and the extent of concordance were 121.57-175. 95 cm3, -354. 135-56. 62 cm3 for semiautomated measurements, and 180. 09-240. 56 cm3 , - 438. 66-18. 01 cm3 for manual measurements,respectively. Conclusion Semi-automated method for the volumetric measurements of the right liver lobes in LDLT is more accurate than the manual method.  相似文献   

17.
目的探讨舟骨螺旋CT影像的最大长度、近端尺侧关节面与最长轴的夹角,以及二者的性别、侧别差异。方法收集30例60侧正常舟骨的螺旋CT数据,利用软件VxWork计算舟骨的最大长度、最长轴的端点位置、近端尺侧关节面与最长轴的夹角α,并检验上述数据有无性别、侧别及观察者内的差异。结果30例60侧舟骨的最大长度均值是(28.05±2.12)mm,男(29.31±1.55)mm,女(26.6±1.83)mm;男性长于女性,但侧别之间无统计学差异。∠α的均值是(23.81±2.45)°,男(23.25±2.40)°,女(24.86±2.50)°;性别、侧别之间均无统计学差异,也无显著的观察者内差异。舟骨最长轴的端点分别在舟骨远、近端的皮质上,位置较恒定;远端位于舟骨结节区的中央,近端在舟骨近端关节面背缘中1/3处;左右两侧对称。结论舟骨螺旋CT影像最大长度、近端尺侧关节面与最长轴的夹角较恒定,且无侧别差异;以健侧舟骨影像数据为依据,用以判断患侧舟骨形变是可行的。  相似文献   

18.
目的探讨运用年龄校正公式的3D-CT肝脏体积测量方法评估活体肝移植(LDLT)供体肝体积的准确性。方法回顾性分析LDLT供体135名,分为≤30岁组(48名)和>30岁组(87名),前瞻性分析LDLT供体45名,分为≤30岁组(19名)和>30岁组(26名)。回顾性分析中,比较不同年龄组间3D-CT测量右半肝体积误差率,通过对术中右半肝实际体积、3D-CT测量体积及年龄进行线性回归分析,获得年龄校正公式。将公式应用于前瞻性分析,计算不同年龄组中运用年龄校正公式前后3D-CT测量肝体积的误差率。结果回顾性研究中,≤30岁组3D-CT测量肝体积误差率[(15.48±8.76)%]高于>30岁组[(10.87±5.24)%,P<0.05];年龄校正公式为:V实际=72.576+0.715×VCT+1.282×年龄(r2=0.786,P<0.001)。前瞻性研究中,运用年龄校正公式3D-CT测量肝体积误差率为(9.32±6.13)%,低于与未运用年龄校正公式误差率[(13.16±7.69)%,P<0.05];运用与未运用年龄校正公式3D-CT测量肝体积误差率在≤30岁组中分别为(10.84±7.13)%和(15.93±8.94)%(P<0.05),在>30岁组中分别为(9.07±5.73)%和(11.01±6.05)%(P>0.05)。结论年龄校正公式能降低3D-CT测量LDLT年轻(≤30岁)供体肝体积的误差率,具有重要应用价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号