首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Biodegradable polymer/bioceramic composites scaffold can overcome the limitation of conventional ceramic bone substitutes such as brittleness and difficulty in shaping. To better mimic the mineral component and the microstructure of natural bone, novel nano-hydroxyapatite (NHA)/polymer composite scaffolds with high porosity and well-controlled pore architectures as well as high exposure of the bioactive ceramics to the scaffold surface is developed for efficient bone tissue engineering. In this article, regular and highly interconnected porous poly(lactide-co-glycolide) (PLGA)/NHA scaffolds are fabricated by thermally induced phase separation technique. The effects of solvent composition, polymer concentration, coarsening temperature, and coarsening time as well as NHA content on the micro-morphology, mechanical properties of the PLGA/NHA scaffolds are investigated. The results show that pore size of the PLGA/NHA scaffolds decrease with the increase of PLGA concentration and NHA content. The introduction of NHA greatly increase the mechanical properties and water absorption ability which greatly increase with the increase of NHA content. Mesenchymal stem cells are seeded and cultured in three-dimensional (3D) PLGA/NHA scaffolds to fabricate in vitro tissue engineering bone, which is investigated by adhesion rate, cell morphology, cell numbers, and alkaline phosphatase assay. The results display that the PLGA/NHA scaffolds exhibit significantly higher cell growth, alkaline phosphatase activity than PLGA scaffolds, especially the PLGA/NHA scaffolds with 10 wt.% NHA. The results suggest that the newly developed PLGA/NHA composite scaffolds may serve as an excellent 3D substrate for cell attachment and migration in bone tissue engineering.  相似文献   

2.
This study evaluated the formation of chitosan-50:50 poly-lactic-co-glycolic acid (PLGA) blend matrices using controlled-rate freezing and lyophilization technique (CRFLT). An emulsion system was used in the presence of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC), a cellular component, as a stabilizer. Blended scaffolds showed an open pore morphology and homogenous interdispersion of PLGA and chitosan. Forming emulsions after dissolving PLGA in chloroform, benzene, or methylene chloride indicated better emulsion stability with benzene and chloroform. Scaffolds formed by freezing at -20, -78, and -196 degrees C from these emulsions showed significant influence of the solvent and freezing temperature on the microarchitecture of the scaffold. By controlling the concentration of chitosan, scaffolds with greater than 90% porosity were attained. Since the two polymers degrade by different mechanisms, formed scaffolds were analyzed for degradation characteristics for 4 weeks in presence of 10 mg/L lysozyme. These results showed no significant difference in the weight loss and dimension changes, as all scaffolds showed significant (a) weight loss and (b) nearly 60% reduction in volume. Further, pH of the incubation media decreased in all the samples. When cellular activity of green fluorescence protein-transfected smooth muscle cells was analyzed, no apparent cytotoxicity was observed. However, the cell spreading area decreased. In summary, these results show promising potential in tissue engineering and drug delivery applications.  相似文献   

3.
—Rifampicin-loaded poly(D,L-lactide) (PDLLA) microspheres in the size range of 0.8-8.0μm were prepared by a modified solvent evaporation method. Rifampicin loading was changed by using different types of solvents (i.e. methylene chloride, chloroform, and carbon tetrachloride) with different solvent/polymer ratios and different emulsifiers (i.e. methyl cellulose, gelatin, and Tween-20), and by changing the initial drug/polymer ratio. These rifampicin-loaded PDLLA microspheres degraded much faster in the medium at basic pH (9.8) and at high temperatures (55°C). Rifampicin release was also high under these conditions. It was concluded that rifampicin release was both degradation- and diffusion-controlled.  相似文献   

4.
Biodegradable polymeric devices for drug delivery and tissue engineering are often fabricated with the use of organic solvents and may still contain significant amounts of solvent (> 1 wt%) even after aggressive vacuum drying. This excess solvent can interfere with tissue response and the mechanical properties of the devices. The aim of this article is to demonstrate that liquid CO(2) extraction can be used to reduce residual solvent in dense poly(L-lactide-co-glycolide) devices to 50 ppm relatively quickly and with minimal changes in architecture under some conditions. Two liquid CO(2) extraction systems were developed to examine the removal of residual solvents from bar-shaped PLGA devices: (1) a low-pressure (1400 psi) batch system, and (2) a high-pressure (5000 psi) continuous-flow system. Eight hours of extraction in the high-pressure system reduced residual chloroform in 3 mm thick bars below the 50-ppm target. A simple Fickian diffusion model was fit to the extraction results. Diffusion coefficients ranged from 1.10 x 10(-6) cm(2)/s to 2.64 x 10(-6) cm(2)/s. The model predicts that approximately 1 h is needed to dry 1-mm bars to chloroform levels below 50 ppm, and 7 h are needed for 3 mm thick bars. The micro- and macroarchitectures of porous PLGA scaffolds created by particulate leaching were not significantly altered by CO(2) drying if the salt used to make the pores was not removed before drying.  相似文献   

5.
This study investigated the in vitro degradation of porous poly(propylene fumarate) (PPF-based) composites incorporating microparticles of blends of poly(DL-lactic-co-glycolic acid) (PLGA) and poly(ethylene glycol) (PEG) during a 26-week period in pH 7.4 phosphate-buffered saline at 37 degrees C. Using a fractional factorial design, four formulations of composite scaffolds were fabricated with varying PEG content of the microparticles, microparticle mass fraction of the composite material, and initial leachable porogen content of the scaffold formulations. PPF scaffolds without microparticles were fabricated with varying leachable porogen content for use as controls. The effects of including PLGA/PEG microparticles in PPF scaffolds and the influence of alterations in the composite formulation on scaffold mass, geometry, water absorption, mechanical properties and porosity were examined for cylindrical specimens with lengths of 13 mm and diameters of 6.5 mm. The composite scaffold composition affected the extent of loss of polymer mass, scaffold length, and diameter, with the greatest loss of polymer mass equal to 15+/-5% over 26 weeks. No formulation, however, exhibited any variation in compressive modulus or peak compressive strength over time. Additionally, sample porosity, as determined by both mercury porosimetry and micro-computed tomography did not change during the period of this study. These results demonstrate that microparticle carriers can be incorporated into PPF scaffolds for localized delivery of bioactive molecules without altering scaffold mechanical or structural properties up to 26 weeks in vitro.  相似文献   

6.
载牛血清蛋白的PLGA纳米粒制备工艺的优化及特性研究   总被引:1,自引:1,他引:0  
目的制备载牛血清蛋白(BSA)的PLGA纳米粒(NPs),采用正交试验设计对工艺进行优化筛选,并研究其特性。方法以聚乳酸-羟基乙酸共聚物[poly(lactic-co-glycolic acid),PLGA]为载体,二氯甲烷(DCM)和丙酮为有机溶剂,采用复乳化溶剂挥发法制备载BSA的PLGA载药纳米粒。扫描电镜观察纳米粒形态,纳米粒度分析仪测定平均粒径和粒径分布;BCA法测定纳米粒的包封率;同时考察其体外释放特性。结果优化条件下制备的纳米粒呈大小均匀的球形粒子,平均粒径为219nm,包封率为44.7%;体外释放分初期突释和后期缓释两阶段,其2~28d的释放曲线符合Higuchi方程,28d末的累积释放量为87.37%。结论以PLGA为载体的BSA纳米粒具有较小的粒径、较高包封率和明显的缓释性能。  相似文献   

7.
Kim SS  Sun Park M  Jeon O  Yong Choi C  Kim BS 《Biomaterials》2006,27(8):1399-1409
Biodegradable polymer/bioceramic composite scaffolds can overcome the limitations of conventional ceramic bone substitutes such as brittleness and difficulty in shaping. However, conventional methods for fabricating polymer/bioceramic composite scaffolds often use organic solvents (e.g., the solvent casting and particulate leaching (SC/PL) method), which might be harmful to cells or tissues. Furthermore, the polymer solutions may coat the ceramics and hinder their exposure to the scaffold surface, which may decrease the likelihood that the seeded osteogenic cells will make contact with the bioactive ceramics. In this study, a novel method for fabricating a polymer/nano-bioceramic composite scaffold with high exposure of the bioceramics to the scaffold surface was developed for efficient bone tissue engineering. Poly(D,L-lactic-co-glycolic acid)/nano-hydroxyapatite (PLGA/HA) composite scaffolds were fabricated by the gas forming and particulate leaching (GF/PL) method without the use of organic solvents. The GF/PL method exposed HA nanoparticles at the scaffold surface significantly more than the conventional SC/PL method does. The GF/PL scaffolds showed interconnected porous structures without a skin layer and exhibited superior enhanced mechanical properties to those of scaffolds fabricated by the SC/PL method. Both types of scaffolds were seeded with rat calvarial osteoblasts and cultured in vitro or were subcutaneously implanted into athymic mice for eight weeks. The GF/PL scaffolds exhibited significantly higher cell growth, alkaline phosphatase activity, and mineralization compared to the SC/PL scaffolds in vitro. Histological analyses and calcium content quantification of the regenerated tissues five and eight weeks after implantation showed that bone formation was more extensive on the GF/PL scaffolds than on the SC/PL scaffolds. Compared to the SC/PL scaffolds, the enhanced bone formation on the GF/PL scaffolds may have resulted from the higher exposure of HA nanoparticles at the scaffold surface, which allowed for direct contact with the transplanted cells and stimulated the cell proliferation and osteogenic differentiation. These results show that the biodegradable polymer/bioceramic composite scaffolds fabricated by the novel GF/PL method enhance bone regeneration compared with those fabricated by the conventional SC/PL method.  相似文献   

8.
This study investigated the in vivo degradation of poly(propylene fumarate) (PPF)/poly(DL-lactic-co-glycolic acid) (PLGA) composite scaffolds designed for controlled release of osteogenic factors. PPF/PLGA composites were implanted into 15.0mm segmental defects in the rabbit radius, harvested after 12 and 18 weeks, and analyzed using histological techniques to assess the extent of polymer degradation as well as the tissue response within the pores of the scaffolds. Polymer degradation was limited to micro-fragmentation of the scaffold at the ends and edges of the implant at both 12 and 18 weeks. The tissue within the pores of the scaffold consisted of fibrous tissue, blood vessels and some inflammatory cells. In areas where polymer breakdown was evident, an increased inflammatory response was observed. In contrast, areas of bone ingrowth into the polymer scaffold were characterized by minimal inflammatory response and polymer degradation. Our results show that minimal degradation of porous PPF occurs within 18 weeks of implantation in a rabbit model. Further, the in vivo degradation data of porous PPF/PLGA scaffolds are comparable with earlier obtained in vitro data.  相似文献   

9.
Biodegradable polymer/ceramic scaffolds can overcome the limitations of conventional ceramic bone substitutes. However, the conventional methods of polymer/ceramic scaffold fabrication often use organic solvents, which might be harmful to cells or tissues. Moreover, scaffolds fabricated with the conventional methods have limited ceramic exposure on the scaffold surface since the polymer solution envelopes the ceramic particles during the fabrication process. In this study, we developed a novel fabrication method for the efficient exposure of ceramic onto the scaffold surface, which would enhance the osteoconductivity and wettability of the scaffold. Poly(D,L-lactide-co-glycolide)/nanohydroxyapatite (PLGA/HA) scaffolds were fabricated by the gas foaming and particulate leaching (GF/PL) method without the use of organic solvents. Selective staining of ceramic particles indicated that HA nanoparticles exposed to the scaffold surface were observed more abundantly in the GF/PL scaffold than in the conventional solvent casting and particulate leaching (SC/PL) scaffold. Both types of scaffolds were implanted to critical size defects in rat skulls for 8 weeks. The GF/PL scaffolds exhibited significantly enhanced bone regeneration when compared with the SC/PL scaffolds. Histological analyses and microcomputed tomography of the regenerated tissues showed that bone formation was more extensive on the GF/PL scaffolds than on the SC/PL scaffolds. Compared with the SC/PL scaffolds, the enhanced bone formation on the GF/PL scaffolds may result from the higher exposure of HA nanoparticles to the scaffold surface. These results show that the biodegradable polymer/ceramic composite scaffolds fabricated with the novel GF/PL method can enhance bone regeneration compared with those fabricated with the conventional SC/PL method.  相似文献   

10.
Kim SS  Park MS  Gwak SJ  Choi CY  Kim BS 《Tissue engineering》2006,12(10):2997-3006
Although biodegradable polymer/ceramic composite scaffolds can overcome the limitations of conventional ceramic bone substitutes, the osteogenic potential of these scaffolds needs to be further enhanced for efficient bone tissue engineering. In this study, bonelike apatite was efficiently coated onto the scaffold surface by using polymer/ceramic composite scaffolds instead of polymer scaffolds and by using an accelerated biomimetic process to enhance the osteogenic potential of the scaffold. The creation of bonelike, apatite-coated polymer scaffold was achieved by incubating the scaffolds in simulated body fluid (SBF). The apatite growth on porous poly(D,L-lactic-co-glycolic acid)/nanohydroxyapatite (PLGA/ HA) composite scaffolds was significantly faster than on porous PLGA scaffolds. In addition, the distribution of coated apatite was more uniform on PLGA/HA scaffolds than on PLGA scaffolds. After a 5-day incubation period, the mass of apatite coated onto PLGA/HA scaffolds incubated in 5 x SBF was 2.3-fold higher than PLGA/HA scaffolds incubated in 1 x SBF. Furthermore, when the scaffolds were incubated in 5 x SBF for 5 days, the mass of apatite coated onto PLGA/HA scaffolds was 4.5-fold higher than PLGA scaffolds. These results indicate that the biomimetic apatite coating can be accelerated by using a polymer/ceramic composite scaffold and concentrated SBF. When seeded with osteoblasts, the apatite-coated PLGA/HA scaffolds exhibited significantly higher cell growth, alkaline phosphatase activity, and mineralization in vitro compared to the apatite-coated PLGA scaffolds. Therefore, the apatite-coated PLGA/HA scaffolds may provide enhanced osteogenic potential when used as scaffold for bone tissue engineering.  相似文献   

11.
胡露  魏坤  邹芬 《中国组织工程研究》2016,20(47):6887-7005
BACKGROUND: Some disadvantages exsist in commonly used poly(lactic-co-glycolic acid) (PLGA) scaffolds, including acidic degradation products, suboptimal mechanical properties, low pore size, poor porosity and pore connectivity rate and uncontrollable shape. OBJECTIVE: To construct a scaffold with three-dimensional (3D) pores by adding calcium silicate to improve the properties of PLGA, and then detect its degradability, mechanical properties and biocompatibility. METHODS: PLGA/calcium silicate porous composite microspheres were prepared by the emulsion-solvent evaporation method, and PLGA 3D porous scaffold was established by 3D-Bioplotter, and then PLGA/calcium silicate composite porous scaffolds were constructed by combining the microspheres with the scaffold using low temperature fusion technology. The compositions, morphology and degradability of the PLGA/calcium silicate porous composite microspheres and PLGA microspheres, as well as the morphology, pore properties and compression strength of the PLGA 3D scaffolds and PLGA/calcium silicate composite porous scaffolds were measured, respectively. Mouse bone marrow mesenchymal stem cells were respectively cultivated in the extracts of PLGA/calcium silicate porous composite microspheres and PLGA microspheres, and then were respectively seeded onto the PLGA 3D scaffolds and PLGA/calcium silicate composite porous scaffolds. Thereafter, the cell proliferation activity was detected at 1, 3 and 5 days. RESULTS AND CONCLUSION: Regular pores on the PLGA microspheres and internal cavities were formed, and the PH values of the degradation products were improved after adding calcium silicate. The fiber diameter, pore, porosity and average pore size of the composite porous scaffolds were all smaller than those of the PLGA scaffolds. The compression strength and elasticity modulus of the composite porous scaffolds were both higher than those of the PLGA scaffolds (P < 0.05). Bone marrow mesenchymal stem cells grew well in above microsphere extracts and scaffolds. These results indicate that PLGA/calcium silicate composite porous scaffolds exhibit good degradability in vitro, mechanical properties and biocompatibility.  相似文献   

12.
While methods for the production of scaffolds with the appropriate mechanical properties and architecture for tissue engineering are attracting much attention, the effects of subsequent sterilization processes on the scaffold properties have often been overlooked. This study sought to determine the effects of sterilization with ethanol, peracetic acid, ultraviolet irradiation, and antibiotic solution on the structure of 50:50 (mol:mol) 65:35, and 85:15 poly(D,L-lactic-co-glycolic acid [PLGA]) flat-sheet and hollow-fiber scaffolds. All methods resulted in scaffold sterilization, but scanning electron microscopy revealed deformations to the scaffold surface for all treatments. The extent of surface damage increased with treatment duration. This was further investigated by measurement of pore sizes, water flux, breaking strain, and Young's modulus. External pore size and water flux was found to be increased by all treatments in the following order: ethanol (largest), antibiotics, ultraviolet light, and peracetic acid. Pore sizes were 0.25 to 0.17 microm and water flux ranged from 0.01 kg x m(-2) x s(-1) to 3.34 kg x m(-2) x s(-1). For all samples, the Young's modulus was 1.0 to 31.1 MPa and breaking strain was 1.2 to 2.4 MPa. The results of this study suggest that antibiotic treatment shows the most potential to sterilize PLGA hollow fibers for tissue engineering.  相似文献   

13.
Poly(lactide-co-glycolide) (PLGA) scaffolds have been successfully used in bone tissue engineering, with or without hydroxyapatite (HA) and with a macroporosity given either by simple PLGA sphere packaging and/or by leaching out NaCl. The objective of this work was the optimization of the design parameters for bone tissue engineering scaffolds made by sintering microspheres of PLGA, HA nanocrystals for matrix reinforcement and osteoconduction, and salt crystals for macroporosity and control of matrix pore size. Microsphere fabrication by a single-emulsion and solvent evaporation technique was first optimized to obtain a high yield of PLGA microspheres with a diameter between 80 and 300 microm. The influence of the sintering process and matrix composition on the scaffold structure was then evaluated morphologically and mechanically. Three scaffold types were tested for biocompatibility by culturing with human fibroblasts for up to 14 days. The most important parameters to obtain microspheres with the selected diameter range were the viscosity ratio of the dispersed phase to the continuous phase and the relative volume fraction of the 2 phases. The Young's modulus and the ultimate strength of the sintered matrices ranged between 168-265 MPa and 6-17 MPa, respectively, within the range for trabecular bone. Biocompatibility was demonstrated by fibroblast adhesion, proliferation, and spreading throughout the matrix. This work builds upon previous work of the PLGA/HA sintering technique to give design criteria for fabricating a bone tissue engineered matrix with optimized morphological, functional, and biological properties to fit the requirements of bone replacements.  相似文献   

14.
A degradable, polar/hydrophobic/ionic polyurethane (D-PHI) scaffold was optimized in in vitro studies to yield mechanical properties appropriate to replicate vascular graft tissue while eliciting a more wound-healing phenotype macrophage when compared to established materials. The objectives of this study were to characterize the biodegradation (in vitro and in vivo) and assess the in vivo biocompatibility of D-PHI, comparing it to a well-established, commercially-available scaffold biomaterial, polylactic glycolic acid (PLGA), recognized as being degradable, non-cytotoxic, and showing good biocompatibility. PLGA and D-PHI were formed into 6 mm diameter disk-shaped scaffolds (2 mm thick) of similar porosity (~82%) and implanted subcutaneously in rats. Both PLGA and D-PHI scaffolds were well-tolerated at the 7 d time point in vivo. In vitro D-PHI scaffolds degraded slowly (only 12 wt% in PBS in vitro after 120 d at 37 °C). In vivo, D-PHI scaffolds degraded at a more controlled rate (7 wt% loss over the acute 7 d implant phase and subsequently a linear profile of degradation leading to a 21 wt% mass loss by 100 d (chronic period)) than PLGA scaffolds which showed an initial more rapid degradation (14 wt% over 7 d), followed by minimal change between 7 and 30 d, and then a very rapid breakdown of the scaffold over the next 60 d. Histological examination of D-PHI scaffolds showed tissue ingrowth into the pores increased with time whereas PLGA scaffolds excluded cells/tissue from its porous structure as it degraded. The results of this study suggest that D-PHI has promising qualities for use as an elastomeric scaffold material for soft TE applications yielding well integrated tissue within the scaffold and a controlled rate of degradation stabilizing the form and shape of the implant.  相似文献   

15.
Scaffolding plays pivotal role in tissue engineering. In this work, a novel processing technique has been developed to create three-dimensional biodegradable polymer scaffolds with well-controlled interconnected spherical pores. Paraffin spheres were fabricated with a dispersion method, and were bonded together through a heat treatment to form a three-dimensional assembly in a mold. Biodegradable polymers such as PLLA and PLGA were dissolved in a solvent and cast onto the paraffin sphere assembly. After dissolving the paraffin, a porous polymer scaffold was formed. The fabrication parameters were studied in relation to the pore shape, interpore connectivity, pore wall morphology, and mechanical properties of the polymer scaffolds. The compressive modulus of the scaffolds decreased with increasing porosity. Longer heat treatment time of the paraffin spheres resulted in larger openings between the pores of the scaffolds. Foams of smaller pore size (100-200 microm) resulted in significantly lower compressive modulus than that of larger pore sizes (250-350 or 420-500 microm). The PLLA foams had a skeletal structure consisting of small platelets, whereas PLGA foams had homogeneous skeletal structure. The new processing technique can tailor the polymer scaffolds for a variety of potential tissue engineering applications because of the well-controlled architecture, interpore connectivity, and mechanical properties.  相似文献   

16.
Electric field-driven fiber formation (electrospinning) is developing into a practical means for preparing novel porous filament with unusual structures and affordable mechanical properties. Polycaprolactone (PCL) was dissolved in solvent mixtures of methylene chloride/N,N-dimethyl formamide with ratios of 100/0, 75/25, and 50/50 (v/v) for electrospinning. The filament was formed by coagulation of the spinning solution following the well-known principle of phase separation in polymer solutions valid in other wet shaping processes. A strand of electrospun porous filament consisted of fibers ranging from 0.5 to 12 microm in diameter. To evaluate the feasibility of three-dimensional fabric as scaffold matrices, the plain weave, which is the simplest of the weaves and the most common, was prepared with porous PCL filament. The growth characteristics of MCF-7 mammary carcinoma cells in the woven fabrics showed the important role of matrix microstructure in proliferation. This study has shown that woven fabrics, consisting of porous filaments via electrospinning, may be suitable candidates as tissue engineering scaffolds.  相似文献   

17.
In this study, we present a novel composite scaffold fabricated using a thermally induced phase separation (TIPS) process from poly(lactic-co-glycolic) (PLGA) and biomedical polyurethane (PU). This processing method has been tuned to allow intimate (molecular) mixing of these two very different polymers, giving rise to a unique morphology that can be manipulated by controlling the phase separation behaviour of an initially homogenous polymer solution. Pure PLGA scaffolds possessed a smooth, directional fibrous sheet-like structure with pore sizes of 0.1-200mum, a porous Young's modulus of 93.5kPa and were relatively brittle to touch. Pure PU scaffolds had an isotropic emulsion-like structure, a porous Young's modulus of 15.7kPa and were much more elastic than the PLGA scaffolds. The composite PLGA/PU scaffold exhibits advantageous morphological, mechanical and cell adhesion and growth supporting properties, when compared with scaffolds fabricated from PLGA or PU alone. This novel method provides a mechanism for the formation of tailored bioactive scaffolds from nominally incompatible polymers, representing a significant step forward in scaffold processing for tissue-engineering applications.  相似文献   

18.
Tissue engineering scaffolds with a micro- or nanoporous structure and able to deliver special drugs have already been confirmed to be effective in bone repair. In this paper, we first evaluated the biomineralization properties and drug release properties of a novel mesoporous silica–hydroxyapatite composite material (HMS–HA) which was used as drug vehicle and filler for polymer matrices. Biomineralization can offer a credible prediction of bioactivity for the synthetic bone regeneration materials. We found HMS–HA exhibited good apatite deposition properties after being soaked in simulated body fluid (SBF) for 7 days. Drug delivery from HMS–HA particle was in line with Fick’s law, and the release process lasted 12 h after an initial burst release with 60% drug release. A novel tissue engineering scaffold with the function of controlled drug delivery was developed, which was based on HMS–HA particles, poly(lactide-co-glycolide) (PLGA) and microspheres sintering techniques. Mechanical testing on compression, degradation behavior, pH-compensation effect and drug delivery behavior of PLGA/HMS–HA microspheres sintered scaffolds were analyzed. Cell toxicity and cell proliferation on the scaffolds was also evaluated. The results indicated that the PLGA/HMS–HA scaffolds could effectively compensate the increased pH values caused by the acidic degradation product of PLGA. The compressive strength and modulus of PLGA/HMS–HA scaffolds were remarkably high compared to pure PLGA scaffold. Drug delivery testing of the PLGA/HMS–HA scaffolds indicated that PLGA slowed gentamycin sulfate (GS) release from HMS–HA particles, and the release lasted for nearly one month. Adding HMS–HA to PLGA scaffolds improved cytocompatibility. The scaffolds demonstrated low cytotoxicity, and supported mesenchymal stem cells growth more effectively than pure PLGA scaffolds. To summarize, the data supports the development of PLGA/HMS–HA scaffolds as potential degradable and drug delivery materials for bone replacement.  相似文献   

19.
This study developed a solvent merging/particulate leaching method for preparing three-dimensional porous scaffolds. Poly(L-lactic-co-glycolic acid) (PLGA) and sodium chloride particles were dry-mixed and cast into a special mold, through which a liquid could pass due to a pressure difference. An organic solvent was then poured into the mold to dissolve and merge the PLGA particles under negative pressure. A nonsolvent was conducted into the PLGA/salt composite to solidify and precipitate the merged PLGA matrix. Finally, a large amount of water was passed through the mold to leach out the salt particles so as to create a porous structure. The results revealed that a highly porous three-dimensional scaffold (>85 vol %) with a well interconnected porous structure could be achieved by this process. Porosity and the pore size of the scaffold were controlled using the ratio and the particle size of the added salt particles. A larger-volume scaffold was produced using a larger mold. This work provides a continuous and simple procedure for fabricating a bulk three-dimensional porous scaffold for tissue engineering.  相似文献   

20.
应用先进快速成形技术(RP)制备32枚粒度均匀(尺寸均为4mm×4mm×4mm)的聚乳酸-聚羟乙酸(PLGA)人工载体,该载体经I型胶原表面修饰后均分为A、B两组。A组载体复合人骨形态发生蛋白-2基因转染(rAAV-hBM P-2)的兔骨髓基质细胞(M SC s,2×104个细胞/枚);B组每枚载体复合等量、同代次、未基因转染M SC s。体外培养第5 d,从两组各取12枚细胞-载体复合物植入裸鼠皮下,术后30 d取材观察。结果发现rAAV-hBM P-2转染的M SC s成功表达目的基因。RP制备的PLGA载体具有良好的空间结构,大孔及材料表面微孔孔径分别为300μm和3~5μm。体外培养3~5 d,两组载体均复合生长着大量种子细胞。皮下埋植30 d,A组植入物形成较为典型的软骨细胞及基质,II型胶原蛋白表达阳性;同期B组植入物无软骨组织形成。A组聚酯材料面积百分率显著低于B组(P<0.01)。结果表明RP结合载体材料表面修饰,能制备出兼具理想孔隙结构和良好生物相容性的组织工程支架载体,该载体高效复合rAAV-hBM P-2转染的M SC s为组织工程软骨构建创造有利条件。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号