首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: Prostate cancer detection at levels of 2.5 to 4.0 ng/ml in a Japanese urological referral population has not been elucidated. The purpose of this study is to investigate the cancer detection rate and clinical relevance of prostate cancer in this PSA range. MATERIALS AND METHODS: All urological patients 70 years or younger tested for prostate cancer were studied. There were 550, 97, 112 and 52 patients with a PSA of less than 2.5, 2.5 to 4.0, 4.1 to 10.0 and more than 10.0 ng/ml, respectively. Transrectal 10-core prostate biopsy was performed in 80 (82%) of the 97 patients with a PSA of 2.5 to 4.0 ng/ml and 102 (91%) of the 112 patients with a PSA of 4.1 to 10.0 ng/ml. RESULTS: Cancer detection rates in patients who underwent biopsy were 26.3% and 34.3% at PSA levels 2.5 to 4.0 and 4.1 to 10.0 ng/ml, respectively. High grade cancers with Gleason score 7 or more were found in 19.0% and 22.9% of patients with cancer with PSA 2.5 to 4.0 and 4.1 to 10.0 ng/ml, respectively. No significant difference was found between the 2 groups in pathological findings on biopsy, including percent positive cores (16.7% vs 20.0%, p = 0.10), maximum cancer length (25.0% vs 30.0%, p = 0.28) and maximum percent cancer length (2.0 vs 3.0 mm, p = 0.17). CONCLUSIONS: Japanese urological referral patients develop prostate cancer quite commonly even if their serum PSA levels are 2.5 to 4.0 ng/ml. Since these cancer cases include high grade, clinically significant cancer, prostate biopsy might be considered at least for selected cases in this PSA range.  相似文献   

2.
Transperineal prostate biopsy after abdominoperineal resection   总被引:2,自引:0,他引:2  
PURPOSE: Prostate cancer evaluation in men who have undergone abdominoperineal resection poses a challenge for urologists. Diagnosis and staging methods are limited because as access to the prostate via digital rectal examination is not possible. Prostate specific antigen (PSA) has been used to screen for malignancy in this population. However, the conventional diagnostic technique with transrectal ultrasound guided biopsies cannot be used. Transperineal ultrasound and biopsy have been described to evaluate the prostate in this setting. We report our experience with transperineal ultrasound biopsy for evaluating the prostate in patients with elevated PSA who have previously undergone abdominoperineal resection. MATERIALS AND METHODS: We reviewed the records of 28 patients treated at 2 institutions. All patients had a history of abdominoperineal resection and subsequent transperineal ultrasound guided prostate biopsy for evaluating elevated PSA. Mean serum PSA in this population was 22 ng./ml. (median 9.5, range 4.1 to 237). Abdominoperineal resection was done in 16 patients (57%) for colorectal cancer, in 11 (39%) for ulcerative colitis and in 1 (4%) for familial polyposis coli. Average time since resection was 14 years (range 1 to 33). Five patients had previously undergone radiation therapy as part of treatment for colorectal cancer before transperineal ultrasound biopsy. RESULTS: Of the 28 biopsies performed 23 revealed prostate cancer, 2 revealed prostatitis and 3 were benign. Average Gleason grade was 6.6 (range 3 to 9). Of the 23 patients with prostate cancer 22 were treated with androgen deprivation therapy (7), prostatectomy (8), external beam (6) and high dose (1) radiation therapy. Of the 8 patients who underwent prostatectomy pathological stage was T2 in 3 and T3 in 4, while pathological findings were not determined in 1 patient in whom the prostate was removed in pieces. CONCLUSIONS: In patients with a history of abdominoperineal resection and elevated PSA transperineal ultrasound guided biopsy of the prostate can provide an accurate tissue diagnosis.  相似文献   

3.
PURPOSE: Little is known about the incidence rate and clinical relevance of prostate cancer in a low prostate specific antigen (PSA) level. In a prospective PSA based screening study we investigated the incidence and clinicopathological features of prostate cancer that occurred within PSA range 1 to 3 ng./ml. when the free-to-total ratio was 0.20 or less. MATERIALS AND METHODS: Men participating in the Aarau, Switzerland, section of the European Randomized Study of Screening for Prostate Cancer between October 1998 and July 2000 were included in the study. As a side study, all men with PSA between 1 and 3 ng./ml. and free-to-total ratio 0.20 or less were invited to undergo further evaluation with ultrasound guided sextant prostate biopsy. RESULTS: Overall, 168 (7.8%) participants fulfilled inclusion criteria. A total of 158 (94%) patients underwent prostate biopsy, and prostate cancer was detected in 17 (10.8%). There were no statistically significant differences between prostate cancer and benign prostatic hyperplasia in regard to patient age (60.7 versus 59.8 years), prostate volume (23.9 versus 23.0 cc), PSA (1.98 versus 1.86 ng./ml.), free-to-total ratio (0.161 versus 0.160), PSA density (0.089 versus 0.076 ng./ml.) or PSA transition zone density (0.33 versus 0.24 ng./ml., respectively). Median Gleason score was 5 on prostate biopsy versus 6 on retropubic prostatectomy specimen. Of the 14 patients who underwent surgery there were positive lymph nodes in 1, stage pT3b Gleason 7 disease in 1, and pathologically organ confined Gleason 5 in 2, Gleason 6 in 5 and Gleason 7 in 5. Mean tumor volume was 1.01 cc (range 0.02 to 5.17). There were 2 (14.3%) insignificant (less than 0.2 cc, Gleason grade 3 or less), 1 (7.1%) minimal (less than 0.5cc, Gleason grade 3 or less) and 11 (78.6%) clinically relevant and potentially harmful cancers. CONCLUSIONS: There is a significant number of prostate cancer cases diagnosed at PSA as low as 1 to 3 ng./ml. A majority of these tumors are clinically significant. This free-to-total ratio range may be helpful for identifying prostate cancer. The "window of opportunity" for detection of curable cancer may change in populations with higher life expectancy towards lower PSA. Lack of specificity and characterization of tumor aggressiveness remains an unsolved issue for PSA.  相似文献   

4.
PURPOSE: Previous studies have indicated that 6-core transrectal prostate biopsy misses a considerable number of cancers. We performed an extensive biopsy protocol of 12-core sampling using both transperineal and transrectal approaches to determine the impact on the cancer detection rate. MATERIALS AND METHODS: We prospectively evaluated 402 men who underwent 6-core transperineal and 6-core transrectal biopsies simultaneously due to abnormal digital rectal examination (DRE) and/or elevated prostate-specific antigen (PSA) levels of 4.0 ng/mL or greater. Using the transperineal approach we obtained four cores from the bilateral peripheral zone targeting the lateral and parasagittal areas and two cores from the bilateral transition zone. The following transrectal biopsy was performed traditionally. We compared cancer detection rate between the extended 12-core procedure and conventional 6-core transperineal and transrectal groups in terms of total PSA and DRE findings. RESULTS: Using the extensive combined method, prostate cancer was detected in 195 cases (48.5%) and the detection rate significantly increased 7.2% and 8.5% compared to the transperineal and transrectal groups, respectively. According to PSA levels and DRE findings, the cancer detection rate by the combined method was significantly improved in patients with PSA levels of 4-10 ng/mL and negative DRE: 10.3% and 11.6% compared to the transperineal and transrectal groups, respectively. CONCLUSIONS: The extensive 12-core method significantly improved the overall cancer detection rate and was especially efficient for men with PSA levels of 4-10 ng/mL accompanied by a negative DRE finding.  相似文献   

5.
PURPOSE: In contemporary screening populations a major drawback of prostate specific antigen (PSA) is its relative lack of specificity, especially in the range of 4 to 10 ng/ml, where prostate cancer is found 25% of the time. ProPSA is a derivative of free PSA (fPSA) consisting of the truncated forms (eg [-2]proPSA, [-4]proPSA or the full-length [-7]proPSA). There is increasing evidence that proPSA is associated preferentially with prostate cancer. The objective of this study was to determine whether proPSA can influence the detection of early prostate cancer. MATERIALS AND METHODS: Archival serum samples obtained from 93 men who underwent a systematic 12-core prostate biopsy (total PSA range 4.0 to 10.0 ng/ml) were assayed for percent free PSA, total PSA and the 3 forms of proPSA (Hybritech Tandem Assays Beckman Coulter Access, Beckman Coulter, Inc., Brea, California). Free PSA, the cumulative sum of individual proPSA forms ([-2], [-4] and [-7], or sum-proPSA) and derivatives were determined. Of the 93 men assessed 41 (44%) had evidence of prostate cancer (76% Gleason 5/6, 19% Gleason 7 and 5% Gleason 8). Prostate volume was measured at systematic 12-core biopsy for the detection of prostate cancer. Results were analyzed using univariate and multivariate logistic regression (LR) nonparametric statistical methods. RESULTS: Using univariate LR, fPSA, percent fPSA (%fPSA), percent sum-proPSA and prostate volume significantly (p <0.05) differentiated men with prostate cancer from those with benign disease. However, applying stepwise backward multivariate LR, total PSA, %fPSA and sum-proPSA were retained and generated a receiver operator characteristic curve with an area under the curve of 76.6%. At 90% sensitivity these 3 variables collectively achieved a specificity of 44% for the detection of prostate cancer. Individually, the 3 retained variables had a specificity of 23% (total PSA), 33% (%fPSA) and 13% (sum-proPSA). CONCLUSIONS: Sum-proPSA, total PSA and %fPSA in combination improve the specificity of early prostate cancer detection in men with a total PSA of 4 to 10 ng/ml compared with the results of individual PSA molecular forms measured.  相似文献   

6.
PURPOSE: The prostate cancer detection rate in patients with elevated prostate specific antigen (PSA) increases with extended needle biopsy protocols. Transperineal biopsy under transrectal ultrasound guidance is rarely reported, although notable cancer diagnoses are obtained with this technique. We describe the results of 6 and 12 core transperineal biopsy. MATERIALS AND METHODS: A total of 214 patients with PSA greater than 4.0 ng/ml were prospectively randomized to undergo 6 or 12 core transperineal biopsy. Each group of 107 patients was comparable in terms of clinical characteristics. The procedure was performed on an outpatient basis using local anesthesia. Specimens were obtained with a fan technique with 2 puncture sites slightly above the rectum (1 per lobe) under transrectal ultrasound guidance. Cores were taken from all peripheral areas, including the far lateral aspect of the prostate. RESULTS: The overall cancer detection rate was 38% and 51% for 6 and 12 core biopsy, respectively. In patients with PSA between 4.1 and 10 ng/ml the cancer detection rate was 30% and 49% for 6 and 12 core biopsy, respectively. CONCLUSIONS: The 12 core transperineal prostate biopsy is superior to 6 core biopsy. The technique provides optimal prostate cancer diagnosis. About half of the patients with PSA greater than 4.0 ng/ml and a slightly lower percent with PSA between 4.1 and 10 ng/ml have prostate cancer.  相似文献   

7.
OBJECTIVES: We compared the detection rates of different transperineal prostate biopsy protocols with the aim to optimize the number of cores to sample according to prostate volume. MATERIAL AND METHODS: From October 2002 to October 2004 we evaluated 480 consecutive patients with PSA between 2.5 and 20 ng/ml undergoing the first set of prostate biopsy. All patients underwent a 14-core TRUS-guided transperineal prostate biopsy, including 12 cores in the peripheral and two in the transitional zone. The detection rate of the 14-core scheme was compared to the one of the other biopsy schemes obtained through the exclusion of pairs of cores. Data were stratified according to the different TRUS estimated prostate volumes. RESULTS: The detection rate of the standard sextant was 35.2%, while those of the 8-core schemes ranged from 37.1 to 38.8%. The 10-core schemes yielded detection rates of 39.6-40.8% and the protocol with 12 biopsies in the peripheral zone diagnosed prostate cancer in 42.1% of the patients. In patients with <30 cc prostate volume, the detection rate of the 14-core scheme was 43.8% and resulted statistically overlapping to the 8-peripheral cores protocol. In patients with 30.1-50 cc prostate volume a 12-peripheral core biopsy reproduced the results of the 14-core sampling. In prostates larger than 50 cc, an even more extensive procedure was mandatory, considering the low detection rate of the 14-core scheme (24.2%). CONCLUSION: Transperineal prostate biopsy is a safe procedure with a very low complication rate and high cancer detection rate. Prostate volume is the most relevant variable in the planning of the optimal number of cores in the extensive first biopsy set. A protocol with more than 8 peripheral cores) is recommended only in patients with prostate volume larger than 30 cc.  相似文献   

8.
PURPOSE: Previous studies have shown that patients with clinical stage T2c-T3 prostate cancer, serum prostate specific antigen (PSA) at diagnosis greater than 20 ng./ml. or a biopsy Gleason score of 8 to 10 are at high risk for disease recurrence after radical prostatectomy. We determined the most important pretreatment predictors of disease recurrence in this high risk population. MATERIALS AND METHODS: We identified 547 patients with high risk prostate cancer who underwent radical prostatectomy at University of California, San Francisco or as part of the Cancer of the Prostate Strategic Urological Research Endeavor data base, a longitudinal disease registry of patients with prostate cancer. High risk disease was defined as 1992 American Joint Committee on Cancer clinical stage T2c-T3 disease in 411 patients, serum PSA at diagnosis greater than 20 ng./ml. in 124 and/or biopsy Gleason score 8 to 10 in 114. Disease recurrence was defined as PSA 0.2 ng./ml. or greater on 2 consecutive occasions after radical prostatectomy or second cancer treatment more than 6 months after surgery. The Cox proportional hazards analysis was performed to determine significant independent predictors of disease recurrence. The likelihood of disease recurrence for clinically relevant patient groups was determined using the Kaplan-Meier method and compared using the log rank test. RESULTS: Median followup after surgery was 3.1 years. Disease recurred in 177 patients (32%). Multivariate analysis demonstrated that serum PSA at diagnosis, biopsy Gleason score, ethnicity and the percent of positive prostate biopsies were significant independent predictors of disease recurrence, while patient age and clinical tumor stage were not. Patients with a Gleason score 8 to 10 tumor and a serum PSA of 10 ng./ml. or less had a significantly higher likelihood of remaining disease-free 5 years after surgery than those with PSA greater than 10 ng./ml. (47% versus 19%, p <0.05). Patients with a serum PSA at diagnosis of greater than 20 ng./ml. and a Gleason score of less than 8 had a significantly higher likelihood of remaining disease-free 5 years after surgery than similar patients with a Gleason score of 8 or greater (45% versus 0%, p <0.05). CONCLUSIONS: PSA, Gleason score, ethnicity and the percent of positive prostate biopsies appear to be the most important pretreatment predictors of disease recurrence in men with high risk prostate cancer. Patients with high grade disease may continue to be appropriate candidates for local therapy if PSA is less than 10 ng./ml. at diagnosis or there are fewer than 66% positive prostate biopsies.  相似文献   

9.
BACKGROUND: We evaluated the improvement in the rate of prostate cancer detection when using a 12-core transperineal biopsy protocol including transitional zone biopsy. METHODS: Between April 2003 and November 2004, 247 consecutive men underwent transperineal systemic 12-core biopsy of the prostate. Six cores were obtained at the peripheral zone, four at the transitional zone and two at the apex. We examined the cancer detection rate in each of the 12 cores, and also determined the improvement of cancer detection resulting from the extensive 12-core versus standard 6-core biopsy. RESULTS: Using the extensive 12-core biopsy, prostate cancer was detected in 98 cases (39.7%). Prostate-specific antigen (PSA), PSA density, the positive rate in digital rectal examination and transrectal ultrasound findings were significantly higher in the prostate cancer group than in the non-prostate cancer group, and prostate volume was larger in non-prostate cancer group. Every site showed almost the same positive rate, between 17.8 and 21.5%. There were 20 cases which were positive in the extended biopsy, but negative in the sextant. The detection improved significantly (20.4%). The improvement of cancer detection in extended biopsy was better in men with PSA levels of 10 ng/mL or less (28.9%), PSA density 0.3 or less (25.8%), negative digital rectal examination (23.3%), and negative transrectal ultrasound (21.6%). Of these twenty patients, no cases with insignificant tumor were detected in the six prostatectomy cases. In particular, three cases of the six were transitional-zone-only cancer. CONCLUSION: Transperineal extended 12-core biopsy including 4 transitional zone cores is a more useful procedure than transperineal 6-core biopsy. Routine transitional zone biopsy, that is different from transrectal biopsy, might be useful for detecting biologically significant cancer.  相似文献   

10.
Prostate cancer detection at low prostate specific antigen   总被引:24,自引:0,他引:24  
PURPOSE: At low prostate specific antigen (PSA) the indication for prostate biopsy is usually an abnormal digital rectal examination. We evaluate the diagnostic value of PSA, digital rectal examination, transrectal ultrasonography and tumor characteristics at low PSA (0 to 4.0 ng./ml.). We confirm and add to recent evidence that digital rectal examination has a low predictive value and that many significant cancers at this PSA range may be missed. MATERIALS AND METHODS: From 1994 to 1997 a total of 10,523 participants 54 to 74 years old were randomized to screening in the Rotterdam section of the European Randomized Study of Screening for Prostate Cancer. Of the participants 9,211 (87.5%) had PSA less than 4.0 ng./ml., and underwent digital rectal examination and transrectal ultrasonography. Expected rates of prostate cancer detection were calculated using logistic regression analysis. Radical prostatectomy was performed in about half of the 478 men diagnosed with prostate cancer. Tumors were characterized by pT category, Gleason score and cancer volume in 166 processed radical prostatectomy specimens. In 50 of these cases PSA was 0 to 4.0 ng./ml. RESULTS: The positive predictive value of digital rectal examination and transrectal ultrasonography at PSA 0 to 4.0 ng./ml. was only 9.7%. Positive predictive value strongly depended on PSA. Sensitivity was calculated by using estimates of the prevalence of sextant biopsy detectable prostate cancers. Of 760 detectable cancers 478 (67%) were diagnosed irrespective of PSA in men screened with digital rectal examination, transrectal ultrasonography and PSA. Only 127 of 348 detectable prostate cancers (36.5%) were actually diagnosed in men with PSA 2 to 4 mg./ml. The importance of these missed cancers was evaluated with parameters of tumor aggressiveness within PSA ranges. CONCLUSIONS: Approximately half of the tumors missed with PSA 0 to 4 ng./ml. had aggressive characteristics (Gleason score 7 or greater, Gleason 4-5 components) and were organ confined. These tumors should be diagnosed and treated according to the present understanding of their natural history. More sensitive and selective screening strategies are needed. Presently a wrong "window of opportunity" is used for early detection of prostate cancer.  相似文献   

11.
目的:探讨前列腺超声造影在经直肠前列腺靶向穿刺活检中的临床应用价值.方法选择96例血清PSA在4~20 ng/ml行前列腺穿刺活检的患者,其中50例行经直肠超声前列腺13针系统性穿刺活检;46例先行经直肠前列腺超声造影,后对超声造影异常增强区靶向穿刺加6点常规穿刺,超声造影无异常者同系统性穿刺.比较两组穿刺活检的效率.结果系统性穿刺组前列腺癌的阳性率为22.0%,造影穿刺组为41.3%,两组间对单纯移行区肿瘤的检出率有统计学差异(P<0.05).系统穿刺组人均穿刺13.0针,单针阳性率为11%;造影穿刺组人均穿刺10.9针,单针阳性率为20%;两组单针阳性率、人均穿刺针数差异均有统计学意义(P<0.05).超声造影异常的患者单针阳性率明显高于普通超声检查的患者(31.5% v s 11.3%),同时人均穿刺针数低于超声引导下系统性穿刺(9.7 vs 13.0针),差异具有统计学意义(P<0.05).系统性穿刺组前列腺癌患者总 Gleason评分为74分,人均6.7分,超声造影穿刺组则分别为133、7.0分,两组比较有统计学差异.两组无严重并发症.结论对于PSA<20 ng/ml 的患者,超声造影对引导经直肠前列腺靶向穿刺活检具有更高的效率,可减轻患者的痛苦.  相似文献   

12.
OBJECTIVES: To evaluate whether three-dimensional 26-core (3D26) prostate biopsy improves the accuracy in predicting the presence of Gleason pattern 4/5 cancer compared with extended transrectal 12-core (TR12) or transperineal 14-core (TP14) biopsy schemes. METHODS: We studied 143 consecutive men in whom prostate cancer was diagnosed by the 3D26 biopsy and who underwent radical prostatectomy (RP) without neoadjuvant treatment. All histologic grading was reevaluated by a single pathologist according to the 2005 International Society of Urological Pathology Consensus Conference on Gleason Grading. Cancer grade was categorized into high grade (Gleason pattern 4/5 cancer present) and non-high grade (absent) in both biopsy and RP specimens. Since TR12 and TP14 biopsy schemes represent subsets of the 3D26 biopsy, we could compare these schemes directly in an identical patient cohort. RESULTS: There was a grade agreement between 3D26 biopsy and RP in 132 (92.3%) cancers. Grade concordance between biopsy and RP was significantly better in 3D26 biopsy than in TR12 (83.5%, p=0.025) biopsy. Risk of underestimation of cancer grade by 3D26 biopsy (26.5%) was significantly lower than that by TP14 (51.4%, p=0.034). Grade concordance between 3D26 biopsy and RP was not according to clinical variables including prostate volume, clinical stage, prostate-specific antigen (PSA), and PSA density. CONCLUSIONS: We demonstrated that the 3D26 biopsy can accurately predict the presence of Gleason pattern 4/5 cancer on RP specimens with a high concordance rate of 92.3%, a value significantly higher than that between extended TR12 biopsy and RP specimens.  相似文献   

13.
The aim of this study is to elucidate the diagnostic efficacy between transperineal and transrectal 12-core prostate biopsy for prostate cancer. We prospectively randomized 200 consecutive men into two groups to undergo systematic prostate biopsy. Overall positivity for cancer was similar (47% by transperineal and 53% by transrectal; P=0.480). However, in case with 'gray zone' PSA (from 4.1 to 10.0 ng/ml), significantly more cores were positive when approach was transperineal, especially among transition zone cores. Therefore, urologist preferences are sufficient for choosing an approach, except for a possible small advantage of transperineal biopsy when PSA is in gray zone.  相似文献   

14.
PURPOSE: Prostate cancer is more common in black than in white American men. Experience in a longitudinal prostate cancer screening program implies that cancer detection is greater in black than in white men with an abnormal digital rectal examination and prostate specific antigen (PSA) less than 4 ng./ml. We investigated potential racial differences in cancer detection in men treated in clinical practice who had an abnormal digital rectal examination and PSA less than 4 ng./ml. MATERIALS AND METHODS: Between January 1992 and December 1999 prostate biopsy was done at a Veterans Affairs Medical Center in 179 black and 357 white men with an abnormal digital rectal examination, PSA less than 4 ng./ml. and no history of prostate surgery. Significant racial differences in demographic and clinical parameters were limited to PSA, which was higher in black men (p = 0.01). RESULTS: Cancer was detected in 38 black (21%) and 65 white (18%) men (p = 0.42). There were no significant racial differences in the PSA adjusted cancer detection rate or in the Gleason score of detected disease. In men with PSA less than 1.0, 1.0 to 1.9, 2.0 to 2.9 and 3.0 to 3.9 ng./ml. the detection rate was 4%, 15%, 27% and 29%, respectively. CONCLUSIONS: In clinical practice prostate cancer detection appears to be equivalent in black and white men when an abnormal digital rectal examination is the only indication of malignancy.  相似文献   

15.
Elabbady AA  Khedr MM 《European urology》2006,49(1):49-53; discussion 53
OBJECTIVE: To evaluate the effect of extended 12-core prostate biopsy in improving the detection rate of prostate cancer and increasing the accuracy of Gleason score. METHODS: This study included 113 patients who underwent TRUS-guided lateral sextant biopsy (group I) and 176 patients who underwent extended 12-core biopsy (group II). Inclusion criteria for prostate biopsy were elevated serum PSA levels (>3.0 ng/ml) and/or suspicious digital rectal examination (DRE). RESULTS: Clinical characteristics were similar in both groups. Cancer was detected in 28 (24.8%) and 64 (36.4%) patients in group I and II respectively, chi2=4.26, p=0.039. Among patients with cancer in group I, 14 were treated by radical prostatectomy (RP). The median Gleason sum was 6 (range 3-8) and 7 (range 5-9) for needle and prostatectomy specimens respectively. There was an agreement between the biopsy and prostatectomy Gleason sum in 7 (50%) patients while the biopsy Gleason sum was lower in 7 (50%) cases. Among patients with cancer in group II, 27 were treated by RP. The median and the range of Gleason sum was the same for needle and prostatectomy specimen (median 6, range 4-9). There was an agreement between the biopsy and prostatectomy specimen in 23 (85.2%) patients while the biopsy sum was lower than prostatectomy in 4 (14.8%) patients. The agreement between the biopsy and prostatectomy specimen was significantly higher in group II (82.5%) than group I (50%), Fisher's Exact Test, p=0.026. CONCLUSION: Extended 12-core prostate biopsy significantly increases both the detection rate of prostate cancer and the accuracy of biopsy Gleason score.  相似文献   

16.
PURPOSE: Percent free prostate specific antigen (PSA) is useful to select patients for prostate biopsy with total PSA 4 to 10 ng./ml. However, 20% of men with PSA between 2.6 and 4 ng./ml. harbor significant prostate cancer and percent free PSA has been suggested to aid in the decision to biopsy in this total PSA range as well. Concerns exist that the number of biopsies needed to detect 1 cancer in this range may be inappropriately high. In a prospective referral population we evaluated sensitivity and specificity of various percent free PSA cutoffs and determined the biopsy-per-cancer ratio in the PSA 2 to 4 ng./ml. range in men with a benign digital rectal examination, and report on the biological nature of the detected cancers based on Gleason score. Results were compared to those obtained from a reference group of patients (PSA 4 to 10 ng./ml., benign digital rectal examination) from the same prospective referral cohort. MATERIALS AND METHODS: Total PSA and free PSA were measured and percent free PSA was calculated. Of the initial 1,602 men 756 had a benign digital rectal examination and PSA 4 to 10 ng./ml., and 219 had a benign digital rectal examination and PSA 2 to 4 ng./ml. Sensitivity, specificity, the number of true positive (evidence of cancer) and false-positive (no evidence of cancer) biopsies were determined. The ratio of true positive biopsies-to-all biopsies performed was used to determine the biopsy-per-cancer ratio. Gleason score of the detected cancers was evaluated. The procedure was repeated for the PSA 4 to 10 ng./ml. range. RESULTS: In the PSA 4 to 10 ng./ml. range a sensitivity of 63.7% to 92.5% with a specificity of 57.5% to 18.7% was found when percent free PSA was 18% to 25%. On average 3 biopsies were needed to detect 1 cancer. When PSA was 2 to 4 ng./ml. sensitivity was 46.3% to 75.6% and specificity was 73.6% to 37.6% when the same percent free PSA cutoff was examined. Calculation of the biopsy-per-cancer ratio for various percent free PSA cutoffs revealed that 3 to 5 biopsies were needed to find 1 cancer. Of 41 cancers detected in the PSA 2 to 4 ng./ml. range 6 had a Gleason score 5. The majority (28 of 41) of cases had a Gleason score of 6. Gleason score was 7 in 5 patients and 8 in 1. CONCLUSIONS: In the PSA 4 to 10 ng./ml. range high sensitivity for prostate cancer detection is critical and 3 biopsies are needed to detect 1 cancer. In the PSA 2 to 4 ng./ml. range a percent free PSA cutoff of 18% to 20% detected about 50% of cancers while sparing up to 73% of unnecessary biopsies with a biopsy-to-cancer ratio of 3 to 4:1. Percent free PSA can be applied to the PSA 2 to 4 ng./ml. range to detect prostate cancer and only moderately increases the number of biopsies needed to detect 1 significant cancer compared to the greater than 4 to 10 ng./ml. range.  相似文献   

17.
PURPOSE: We report the estimates of 10-year prostate specific antigen (PSA) outcome following radical prostatectomy in patients with or without grade 4 or 5 disease in the needle biopsy or prostatectomy specimen stratified by the presenting PSA level. MATERIALS AND METHODS: From 1989 to 2001, 2,254 patients treated with radical prostatectomy for clinically localized prostate cancer comprised the study cohort. PSA outcome was estimated using the actuarial method of Kaplan and Meier, and was stratified by the presenting PSA level and needle biopsy and prostatectomy Gleason score. RESULTS: The 10-year estimates of PSA outcome declined significantly (p 相似文献   

18.
AIM: To establish whether extended transrectal (TR) and extended transperineal (TP) biopsies are equivalent in detecting prostate cancer. METHODS: Due to an elevated prostate-specific antigen (PSA) greater than 2.5 ng/mL or abnormal digital rectal examination findings, 783 men underwent a transrectal ultrasound-guided three-dimensional 26-core biopsy, a combination of TR 12-core and TP 14-core biopsies. Using recursive partitioning, the best combination of sampling sites that gave the highest cancer detection rate at a given number of biopsy cores was selected either with a TR or a TP approach. The cancer detection rate and characteristics of detected cancers were compared between the TP 14-core and the TR 12-core biopsies and between selected subset biopsy schemes. RESULTS: Prostate cancer was detected in 283 of the 783 men (36%). There was no statistical difference in cancer detection rate or in the characteristics of detected cancers between TP 14-core and TR 12-core biopsies. As far as the best combination of sampling sites was selected, there was no statistical difference in cancer detection rates or in the characteristics of detected cancers between the TP and the TR subset biopsy schemes up to 12 cores. TP and TR biopsies performed equally, regardless of a history of negative biopsy, a digital rectal examination finding, the PSA level or the prostate volume. CONCLUSIONS: We demonstrated for the first time that extended TP biopsy is as effective as its TR counterpart in detecting cancer and the characteristics of detected cancers, as far as sampling sites are selected to maximize the cancer detection rate.  相似文献   

19.
PURPOSE: Whether pretreatment factors that predict for time to prostate specific antigen (PSA) failure also predict for time to prostate cancer specific death after PSA failure for patients with competing causes of mortality treated during the PSA era was the subject of this study. MATERIALS AND METHODS: Of 415 men with a median age of 73 years who underwent external beam radiation therapy between 1988 and 2001 for clinically localized prostate cancer 160 (39%) experienced PSA failure and 96 (23%) died. In 46 men (48%) the cause of death was prostate cancer. Cox regression multivariable analyses (multivariable analysis) were performed to evaluate the ability of the pretreatment PSA and centrally reviewed biopsy Gleason score to predict time to prostate cancer specific death after PSA failure. RESULTS: When analyzed as categorical variables using multivariable analysis, biopsy Gleason score 4 + 3 (p = 0.02), 8 to 10 (p = 0.02) disease and a pretreatment PSA greater than 20 ng./ml. (p = 0.03) were significant predictors of time to prostate cancer specific death after PSA failure. Estimates of prostate cancer specific death 5 years after PSA failure were 24%, 40% and 59% (p = 0.01) for patients with a biopsy Gleason score < or = 6, 3 + 4, 4 + 3 or higher and 22%, 40% and 60% (p = 0.04) for patients with a pretreatment PSA of 10 or less, greater than 10 and 20 or less, or greater than 20 ng./ml., respectively. CONCLUSIONS: Patients at high risk for PSA failure after radiation therapy based on pretreatment PSA greater than 20 ng./ml. or biopsy Gleason score 4 + 3 or greater are also at high risk for death from prostate cancer after PSA failure despite competing causes of mortality.  相似文献   

20.
PURPOSE: A negative biopsy result does not necessarily equate with cancer in specific high risk groups. We describe an alternative systematic biopsy technique for evaluating this subgroup of patients. MATERIALS AND METHODS: From March 1997 to May 1999 a total of 88 men underwent systematic ultrasound guided biopsy using the transperineal template technique. All patients had undergone at least 1 and 75 (85%) had undergone 2 or more previous sets of biopsies. In addition, study inclusion required high risk parameters, including prostate specific antigen (PSA) velocity greater than 0.75 ng./ml., PSA greater than 10 ng./ml. or previous prostatic intraepithelial neoplasia on biopsy, and/or atypical small cell acinar proliferation. RESULTS: Cancer was identified in 38 of the 88 men (43%) in this high risk subgroup undergoing repeat biopsy. A mean of 15.1 previous biopsy cores had been obtained. The most common biopsy grade was 6 (range 4 to 9). Adenocarcinoma was identified in the transition zone area in 29 of 38 cases (76%), including 15 (39%) in which disease was detected in the transition zone only. Persistent PSA acceleration greater than 0.75 ng./ml. was the major indicator for transperineal template biopsy in 83 of the 88 patients (94%). The only significant independent variable predictive of positive biopsy was prostate volume. Mean prostate volume in the positive and negative biopsy groups was 48 and 73 gm., respectively (p <0.001). Complications were rare and self-limiting, consisting primarily of hematuria and urinary retention requiring overnight catheterization in 2 patients. CONCLUSIONS: Systematic transperineal template biopsy of the prostate is a safe and precise repeat biopsy technique in patients who remain at high risk for adenocarcinoma.  相似文献   