首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
While the matrix/reinforcement load-transfer occurring at the micro- and nanoscale in nonbiological composites subjected to creep deformation is well understood, this topic has been little studied in biological composites such as bone. Here, for the first time in bone, the mechanisms of time-dependent load transfer occurring at the nanoscale between the collagen phase and the hydroxyapatite (HAP) platelets are studied. Bovine cortical bone samples are subjected to synchrotron X-ray diffraction to measure in situ the evolution of elastic strains in the crystalline HAP phase and the evolution of viscoelastic strains accumulating in the mineralized collagen fibrils under creep conditions at body temperature. For a constant compressive stress, both types of strains increase linearly with time. This suggests that bone, as it deforms macroscopically, is behaving as a traditional composite, shedding load from the more compliant, viscoelastic collagen matrix to the reinforcing elastic HAP platelets. This behavior is modeled by finite-element simulation carried out at the fibrillar level.  相似文献   

2.
While the effects of bone mineral density and architecture in osteoporotic bone have been studied extensively, the micromechanics of yielding and failure have received less attention. However, understanding architectural features associated with failure should provide insight into assessing bone quality. In this study, microstructural finite element models were used to compute regions of tissue level yielding in ten bovine tibial trabecular bone samples. The morphology, number, and mean volume of the yielded regions were quantified for four apparent strains under two loading conditions. For on-axis loading, the mean aspect ratio of the tissue that yielded due to compressive strain increased with increasing apparent strain, expanding along the principal trabecular orientation. This suggests that tissue level yielding progresses along vertical trabeculae when a specimen is loaded on-axis. The number, but not the volume, of the regions yielded due to tensile strain increased with increasing applied load, consistent with relaxation and redistribution of stresses around the yielded regions. When the specimens were compressed perpendicular to the principal axis, the aspect ratio of the yielded regions was close to one, while the number, mean volume, and mean thickness of the yielded regions increased. This indicates that localized high strains consistent with bending rather than axial deformation of struts occur at the tissue level. Overall, the results provide new insight into trabecular bone failure, which is relevant to assessing diagnostic tests for fracture risk or evaluating osteoporosis treatments.  相似文献   

3.
Trabecular bone is a cellular composite material comprising primarily of mineral and organic phases with their content ratio known to change with age. Therefore, the contribution of bone constituents on bone’s mechanical behaviour, in tension and compression, at varying load levels and with changing porosity (which increases with age) is of great interest, but remains unknown. We investigated the mechanical response of demineralised bone by subjecting a set of bone samples to fully reversed cyclic tension–compression loads with varying magnitudes. We show that the tension to compression response of the organic phase of trabecular bone is asymmetric; it stiffens in tension and undergoes stiffness reduction in compression. Our results indicate that demineralised trabecular bone struts experience inelastic buckling under compression which causes irreversible damage, while irreversible strains due to microcracking are less visible in tension. We also identified that the values of this asymmetric mechanical response is associated to the original bone volume ratio (BV/TV).  相似文献   

4.
The mechanical properties of vertebral bone have been widely studied with the ultimate goal of improving fracture risk prediction. However, the mechanical interaction between the cortical shell and the trabecular core is not well understood. The objective of this study was to investigate this interaction and to determine what effect it has on the ultimate strength of the whole bone. This objective was achieved by compression testing rapid prototype (RP) models of cylindrical trabecular bone cores, with and without an integral surrounding shell and incorporating increasing levels of artificially induced bone loss. Corresponding finite element (FE) models were generated and the load sharing of the shell and trabecular core was analysed under linear elastic loading conditions. The results of the physical RP model tests and corresponding FE analyses indicated that there was a reinforcing effect between the cortical shell and the trabecular core for all models tested and that the reinforcing effect became relatively more important to the ultimate strength of the whole bone as the bone volume fraction of the trabecular core decreased. It was found that two mechanisms contributed to the reinforcing effect: (i) load transfer from the highly stressed shell into the connecting outer trabeculae of the core for the shelled model. This did not occur for the un-shelled model where the load dropped off at the outer unsupported trabeculae; (ii) the stiffening effect on the shell due to the support provided by the connecting struts of the trabecular core, which serves to inhibit bending and buckling behaviour in the shell under compression loading. It was found that the stiffening on the shell was the more dominant contributor to the overall reinforcing effect between the shell and the trabecular core.  相似文献   

5.
Extremely low magnitude mechanical stimuli (<10 microstrain) induced at high frequencies are anabolic to trabecular bone. Here, we used finite element (FE) modeling to investigate the mechanical implications of a one year mechanical intervention. Adult female sheep stood with their hindlimbs either on a vibrating plate (30 Hz, 0.3 g) for 20 min/d, 5 d/wk or on an inactive plate. Microcomputed tomography data of 1 cm bone cubes extracted from the medial femoral condyles were transformed into FE meshes. Simulated compressive loads applied to the trabecular meshes in the three orthogonal directions indicated that the low level mechanical intervention significantly increased the apparent trabecular tissue stiffness of the femoral condyle in the longitudinal (+17%, p < 0.02), anterior–posterior (+29%, p < 0.01), and medial-lateral (+37%, p < 0.01) direction, thus reducing apparent strain magnitudes for a given applied load. For a given apparent input strain (or stress), the resultant stresses and strains within trabeculae were more uniformly distributed in the off-axis loading directions in cubes of mechanically loaded sheep. These data suggest that trabecular bone responds to low level mechanical loads with intricate adaptations beyond a simple reduction in apparent strain magnitude, producing a structure that is stiffer and less prone to fracture for a given load. © 2003 Biomedical Engineering Society.  相似文献   

6.
The complex tri-layered structure of the aortic valve (AV) results in anisotropic quasi-static mechanical behaviour. However, its influence on AV viscoelasticity remains poorly understood. Viscoelasticity may strongly influence AV dynamic mechanical behaviour, making it essential to characterise the time-dependent response for designing successful substitutes. This study attempts to characterise the time-dependent behaviour of the AV at different strain and load increments, and to gain insight into the contribution of the microstructure to this behaviour. Uniaxial incremental stress-relaxation and creep experiments were undertaken, and the experimental data analysed with a generalised Maxwell model, to determine the characteristic time-dependent parameters. Results showed that the time dependent response of the tissue differed with the loading direction, and also with the level of applied load or strain, in both stress-relaxation and creep phenomena. Both phenomena were consistently more pronounced in the radial loading direction. Fitting of the Maxwell model highlighted that the time dependent modes required to model the data also varied in different increments, and additionally with the loading direction. These results suggest that different micro-structural mechanisms may be activated in stress-relaxation and creep, determined by the microstructural organisation of the valve matrix in each loading direction, at each strain or load increment.  相似文献   

7.
Little is known about the distributions of mechanical strains and stresses in individual trabeculae of cancellous bone, despite evidence that tissue-level strains affect the metabolism of bone. Recently, micro-finite element (micro-FE) studies have provided the first insights into the mechanical conditions in trabeculae, and suggested that osteoporotic cancellous bone experience higher and substantially less-uniform strains with respect to healthy cancellous bone. We may therefore ask whether the inhomogeneity of bone tissue strains is predominantly a consequence of micro-architectural differences between trabeculae, or is it mostly caused by the curvatures of each individual trabecula. Accordingly, the objectives of the present study were to determine the contribution of the shape of a trabecula to the intra-trabecula strain inhomogeneity, and to determine potential differences in intra-trabecula strain inhomogeneities between normal and thinner, osteoporotic-like trabeculae. We employed our previously reported generic single-trabecula model, which is a mathematical representation of the shape of a trabecula based on statistical analyses of mammalian trabecular dimensions. The single-trabecula model was loaded axially and in bending, and strain distributions were calculated for individual trabeculae as well as for "populations" of trabeculae, formed by assigning different trabecular thickness values in the trabecular model, in order to represent the distributions of trabecular shapes in normal and osteoporotic bones. We found that when subjected to equivalent loads, thinner, osteoporotic-like individual trabeculae and populations of thin trabeculae developed substantially greater strain inhomogeneities compared with normal trabeculae. We conclude that the intra-trabecula strain inhomogeneities are likely to be an important factor contributing to the overall increased strain inhomogeneity in osteoporotic cancellous bone, as previously observed in micro-FE studies.  相似文献   

8.
High-energy synchrotron X-ray diffraction is used to study in situ elastic strains in hydroxyapatite (HAP) for bovine femur cortical bone subjected to uniaxial compressive loading. Load-unload tests at room temperature (27°C) and body temperature (37°C) show that the load transfer to the stiff nanosized HAP platelets from the surrounding compliant protein matrix does not vary significantly (p<0.05) with temperature. This emphasizes that the stiffness of bone is controlled by the stiffness of the HAP phase, which remains unaffected by this change in temperature. Both the extent of hysteresis and the residual value of internal strains developed in HAP during load-unload cycling from 0 to -100 MPa increase significantly (p<0.05) with the number of loading cycles, indicative of strain energy dissipation and accumulation of permanent deformation. Monotonic loading tests, conducted at body temperature to determine the spatial variation of properties within the femur, illustrate that the HAP phase carries lower strain (and thus stresses) at the anterio-medial aspect of the femur than at the anterio-lateral aspect. This is correlated to higher HAP volume fractions in the former location (p<0.05). The Young's modulus of the bone is also found to correlate with the HAP volume fraction and porosity (p<0.05). Finally, samples with a primarily plexiform microstructure are found to be stiffer than those with a primarily Haversian microstructure (p<0.05).  相似文献   

9.
Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated.In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens’ surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies.  相似文献   

10.
In this paper the relationship between three-dimensional histomorphometric parameters derived from microCT and MRI images of distal radius trabecular bone samples is studied. microFE analysis of the trabecular samples is performed and Young's modulus for cranio-caudal direction is calculated. Most of the MRI and microCT parameters correlate significantly with, respectively, MRI and microCT estimates of bone volume fraction. For some of the parameters strong correlation between microCT and MRI results is also observed. However, in these cases there simultaneously exists correlation between: microCT parameter and microCT bone volume fraction; microCT and MRI bone volume fraction; MRI bone volume fraction and MRI parameter. It is found that, comparing to bone volume fraction, histomorphometric information derived from binarized MRI images does not improve estimation of the Young's modulus of trabecular bone samples (calculated for "gold standard" microCT data). Thus a novel method of "optimal paths" analysis of gray-level MRI images is introduced. "Optimal paths" parameters improve estimation of the Young's modulus of trabecular bone samples. They also provide surrogate, gray-level image-based measure of trabecular thickness.  相似文献   

11.
Spontaneous vertebral fractures are a common occurrence in modern humans, yet these fractures are not documented in other hominoids. Differences in vertebral bone strength between humans and apes associated with trabecular bone microarchitecture may contribute to differences in fracture incidence. We used microcomputed tomography to examine trabecular bone microarchitecture in the T8 vertebra of extant young adult hominoids. Scaled volumes of interest from the anterior vertebral body were analyzed at a resolution of 46 μm, and bone volume fraction, trabecular thickness, trabecular number, trabecular separation, structure model index, and degree of anisotropy were compared among species. As body mass increased, so did trabecular thickness, but bone volume fraction, structure model index, and degree of anisotropy were independent of body mass. Bone volume fraction was not significantly different between the species. Degree of anisotropy was not significantly different among the species, suggesting similarity of loading patterns in the T8 vertebra due to similar anatomical and postural relationships within each species' spine. Degree of anisotropy was negatively correlated with bone volume fraction (r2 = 0.85, P < 0.05) in humans, whereas the apes demonstrated no such relationship. This suggested that less dense human trabecular bone was more preferentially aligned to habitual loading. Furthermore, we theorize that trabeculae in ape thoracic vertebrae would not be expected to become preferentially aligned if bone volume fraction was decreased. The differing relationship between bone volume fraction and degree of anisotropy in humans and apes may cause less dense human bone to be more fragile than less dense ape bone. Anat Rec, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

12.
The statistical distribution of von Mises stress in the trabeculae of human vertebral cancellous bone was estimated using large-scale finite element models. The goal was to test the hypothesis that average trabecular von Mises stress is correlated to the maximum trabecular level von Mises stress. The hypothesis was proposed to explain the close experimental correlation between apparent strength and stiffness of human cancellous bone tissue. A three-parameter Weibull function described the probability distribution of the estimated von Mises stress (r2) > 0.99 for each of 23 cases). The mean von Mises stress was linearly related to the standard deviation (r2=0.63) supporting the hypothesis that average and maximum magnitude stress would be correlated. The coefficient of variation (COV) of the von Mises stress was nonlinearly related to apparent compressive strength, apparent stiffness, and bone volume fraction (adjusted r2=0.66, 0.56, 0.54, respectively) by a saturating exponential function [COV=A+B exp(–x/C)]. The COV of the stress was higher for low volume fraction tissue (<0.12) consistent with the weakness of low volume fraction tissue and suggesting that stress variation is better controlled in higher volume fraction tissue. We propose that the average stress and standard deviation of the stress are both controlled by bone remodeling in response to applied loading. © 2000 Biomedical Engineering Society. PAC00: 8719Rr  相似文献   

13.
Limb elements in birds have been characterized as exhibiting a reduction in trabecular bone, thinner cortices and decreased bending strength when pneumatized, yet it is unclear if these characteristics generalize to the axial skeleton. Thin section techniques, the traditional gold standard for bone structure studies, have most commonly been applied to the study of avian bone. This destructive technique, however, makes it subsequently impossible to use the same samples in experimental testing systems that allow researchers to correlate structure with the mechanical properties of the bone. Micro-computed tomography (microCT), a non-destructive X-ray imaging technique, can be used to assess the effect of pneumatization on vertebral cortical and trabecular bone through virtual extraction and structural quantification of each tissue type. We conducted a preliminary investigation of the application of microCT methods to the study of cortical and trabecular bone structure in a small sample of pneumatic and apneumatic thoracic vertebrae. The sample consisted of two similar-sized anatids, Aix sponsa (n = 7) and Oxyura jamaicensis (n = 5). Volumes of interest were created that contoured (outlined) the boundaries of the ventral cortical bone shell, the trabecular compartment and the whole centrum (cortical bone + trabecular bone), and allowed independent structural analysis of each volume of interest. Results indicated that bone volume fraction of the whole centrum was significantly higher in the apneumatic O. jamaicensis than in the pneumatized A. sponsa (A. sponsa = 36%, O. jamaicensis = 48%, P < 0.05). In contrast, trabecular bone volume fraction was similar between the two species. The ventral cortical bone shell was approximately 23% thinner (P < 0.05) in A. sponsa (0.133 mm) compared with apneumatic O. jamaicensis (0.172 mm). This case study demonstrates that microCT is a powerful non-destructive imaging technique that may be applied to the three-dimensional study of avian bone. The preliminary results suggest that pneumatic and apneumatic vertebrae of comparably sized avian species differ in relative bone volume, with the largest difference apparent at the level of the cortex, and not within trabecular bone. The presence of relatively thin cortices in pneumatic vertebrae is consistent with previous studies contrasting diaphyseal cortical bone between pneumatic and apneumatic long bones. Methodological issues related to this and any comparative microCT study of bone structure are discussed.  相似文献   

14.
The microstructure and associated mechanical properties of antler trabecular bone have been studied using a variety of techniques. The local trabeculae properties, as well as the three-dimensional architecture were characterized using nanoindentation and X-ray microtomography, respectively. An elastic modulus of 10.9+/-1.1 GPa is reported for dry bone, compared with 5.4+/-0.9 GPa for fully hydrated bone. Trabeculae thickness and separation were found to be comparable to those of bovine trabecular bone. Uniaxial compression conducted in situ during X-ray microtomography showed that antler can undergo significant architectural rearrangement, dominated by trabeculae bending and buckling, due to its low mineral content. High-energy synchrotron X-ray diffraction was used to measure elastic strains in the apatite crystals of the trabeculae, also under in situ uniaxial compression. During elastic loading, strain was found to be accommodated largely by trabeculae aligned parallel to the loading direction. Prior to the macroscopic yield point, internal strains increased as trabeculae deformed by bending, and load was also found to be redistributed to trabeculae aligned non-parallel to the loading direction. Significant bending of trabecular walls resulted in tensile strains developing in trabeculae aligned along the loading direction.  相似文献   

15.
Trabecular bone structure has been used to investigate the relationship between skeletal form and locomotor behavior on the premise that trabecular bone remodels in response to loading during an animal's lifetime. The aim of this study is to characterize human distal femoral trabecular bone structure in comparison to three non-human primate taxa and relate the patterns of trabecular structural variation in the distal femur to knee posture during habitual locomotor behavior. A whole-epiphysis approach was applied using microCT scans of the distal femora of extant Homo sapiens, Pan troglodytes, Pongo pygmaeus, and Papio spp. (N = 48). Bone volume fraction (BV/TV) was quantified in the epiphysis and analyzed with both whole-condyle and a novel sector analysis. The results indicate high trabecular bone structural variation within and between species. The sector analysis reveals the most distinctive patterns in the stereotypically loaded human knee, with a pattern of high BV/TV distally. In general, Pan, Pongo, and Papio show evidence of flexed knee postures, typical of their locomotor behaviors, with regions of high BV/TV posteriorly within the condyles. The pairwise comparisons confirm the unique pattern in Homo and reveal a shared high BV/TV region in the patellar groove of both Homo and Papio. The distinct pattern found in Homo relative to the other primate taxa suggests a plastic response to unique loading patterns during bipedal locomotion. Results may facilitate resolving the antiquity of habitual bipedality in the hominin fossil record. This analysis also presents new approaches for statistical analysis of whole-epiphysis trabecular bone structure. Anat Rec, 2018. © 2018 American Association for Anatomy.  相似文献   

16.
Microdamage and failure mechanisms have been well characterized in bovine trabecular bone. However, little is known about how elastic strains develop in the apatite crystals of the trabecular struts and their relationship with different deformation mechanisms. In this study, wide-angle high-energy synchrotron X-ray diffraction has been used to determine bulk elastic strains under in situ compression. Dehydrated bone is compared to hydrated bone in terms of their response to load. During compression, load is initially borne by trabeculae aligned parallel to loading direction with non-parallel trabeculae deforming by bending. Ineffective load partitioning is noted in dehydrated bone whereas hydrated bone behaves like a plastically yielding foam.  相似文献   

17.
The trabecular bone morphology of adult extant primates has been shown to reflect mechanical loading related to locomotion. However, ontogenetic studies of humans and other mammals suggest an adaptive lag between trabecular bone response and current mechanical loading patterns that could result in adult trabecular bone morphology reflecting juvenile behaviours. This study investigates ontogenetic changes in the trabecular bone structure of the third metacarpal of mountain gorillas (Gorilla beringei beringei; n = 26) and western lowland gorillas (Gorilla gorilla gorilla; n = 26) and its relationship to expected changes in locomotor loading patterns. Results show that trabecular bone reflects predicted mechanical loading throughout ontogeny. Bone volume fraction, trabecular thickness and trabecular number are low at birth and increase with age, although degree of anisotropy remains relatively stable throughout ontogeny. A high concentration of bone volume fraction can be observed in the distopalmar region of the third metacarpal epiphysis in early ontogeny, consistent with the high frequency of climbing, suspensory and other grasping behaviours in young gorillas. High trabecular bone concentration increases dorsally in the epiphysis during the juvenile period as terrestrial knuckle‐walking becomes the primary form of locomotion. However, fusion of the epiphysis does not take place until 10–11 years of age, and overall trabecular structure does not fully reflect the adult pattern until 12 years of age, indicating a lag between adult‐like behaviours and adult‐like trabecular morphology. We found minimal differences in trabecular ontogeny between mountain and western lowland gorillas, despite presumed variation in the frequencies of arboreal locomotor behaviours. Altogether, ontogenetic changes in Gorilla metacarpal trabecular structure reflect overall genus‐level changes in locomotor behaviours throughout development, but with some ontogenetic lag that should be considered when drawing functional conclusions from bone structure in extant or fossil adolescent specimens.  相似文献   

18.

Purpose

Bone metastasis invariably increases morbidity and mortality. This study compares the effects of ibandronate and paclitaxel on bone structure and its mechanical properties and biochemical turnover in resorption markers using an immunocompetent Walker 256-Sprague-Dawley model, which was subjected to tumor-induced osteolysis.

Materials and Methods

Seventy rats were divided equally into 4 groups: 1) sham group (SHAM), 2) tumor group (CANC), 3) ibandronate treated group (IBAN), and 4) paclitaxel treated group (PAC). Morphological indices [bone volume fraction (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp)] and mechanical properties (failure load, stiffness) were evaluated after thirty days of treatment period. Bone resorption rate was analysed using serum deoxypyridinoline (Dpd) concentrations.

Results

Morphological indices showed that ibandronate (anti-resorptive drug) had a better effect in treating tumor-induced architectural changes in bone than paclitaxel (chemotherapeutic drug). The deterioration in bone architecture was reflected in the biomechanical properties of bone as studied with decreased failure load (Fx) and stiffness (S) of the bone on the 30th day post-surgery. Dpd concentrations were significantly lower in the IBAN group, indicating successful inhibition of bone resorption and destruction.

Conclusion

Ibandronate was found to be as effective as higher doses of paclitaxel in maintaining stiffness of bone. Paclitaxel treatment did not appear to inhibit osteoclast resorption, which is contrary to earlier in-vitro literature. Emphasis should be placed on the use of immunocompetent models for examining drug efficacy since it adequately reflects bone metastasis in clinical scenarios.  相似文献   

19.
Both the load partitioning between hydroxyapatite (HAP) and collagen during compressive creep deformation of bone and the HAP residual strain in unloaded bone have been shown in previous synchrotron X-ray diffraction studies to be affected by the X-ray irradiation dose. Here, through detailed analysis of the X-ray diffraction patterns of bovine bone, the effect of X-ray dose on (i) the rate of HAP elastic strain accumulation/shedding under creep conditions and (ii) the HAP lattice spacing and average root mean square (RMS) strain under load-free conditions are examined. These strain measurements exhibit three stages in response to increasing X-ray dose. Up to ~75 kGy (stage I) no effect of dose is observed, indicating a threshold behavior. Between ~75 and ~300 kGy (stage II) in unloaded bone the HAP d-spacing increases and the RMS strain decreases with dose, indicating strain relaxation of HAP. Furthermore, under constant compressive load creep conditions, the rate of compressive elastic strain accumulation in HAP decreases with increasing dose until, at ~115 kGy, it changes sign, indicating that the HAP phase is shedding load during creep deformation. These stage II behaviors are consistent with HAP–collagen interfacial damage, which allows the HAP elastic strain to relax within both the loaded and unloaded samples. Finally, for doses in excess of ~300 kGy (stage III, measured up to 7771 kGy) the HAP lattice spacing and RMS strain for load-free samples and the rate of HAP elastic strain shedding for crept samples remain independent of dose, suggesting a saturation of damage and/or stiffening of the collagen matrix due to intermolecular cross-linking.  相似文献   

20.
This study describes the timing of development of the trabecular structure of the ulnar medial coronoid process (MCP) in the dog. The right MCPs of nine healthy golden retrievers, aged 4 to 24 weeks, without signs of secondary joint disease were dissected and scanned with microcomputed tomography (micro-CT) at a voxel size of 34 microm to determine histomorphometric parameters. Bone volume fraction and mean trabecular separation show a reciprocal pattern in time, reflecting an initial high bone density (and low trabecular separation), and then a sharp drop in density at 8-10 weeks, followed by a gradual increase to high values at 24 weeks. With a similar bone volume fraction as in young bone, the older bone shows thicker trabeculae and a more plate-like structure. This is reflected in the much smaller number of trabeculae and the lower surface/volume ratio at higher age. An anisotropic structure of the trabeculae with an orientation in the direction of the proximodistal axis of the ulna is already present at 6 weeks after birth. This primary alignment was perpendicular to the humeroulnar articular surface, matching the direction of the compressive forces applied to the MCP by the humeral trochlea. The secondary alignment appeared at 13 weeks after birth and was directed along the craniocaudal axis of the MCP, toward the attachment of the anular ligament. In comparison with data from long bones and vertebrae, the findings of a high bone volume fraction and a well-defined trabecular alignment at a very early age are remarkable. The high bone volume fraction is possibly a remnant of the fetal trabecular structure, as dogs are relatively immature at birth compared to other animals. Soon after the start of steady locomotion, the trabecular structure changes into a more mature-like structure. The early trabecular alignment is possibly a reflection of the early load-bearing function of the MCP in the elbow joint.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号