首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的应用冠状动脉血管内光学相干断层成像技术(optical coherence tomography,OCT)评价造影随访无再狭窄的药物洗脱支架(drug eluting stent,DES)内皮增生情况。方法从北京安贞医院2007年9月至2008年9月连续入选DES术后无症状而接受冠状动脉造影复查无明显再狭窄的患者18例,所有患者接受OCT检查,比较不同的DES植入时间、不同DES组之间,每组支架小梁血管内膜增生情况。结果共分析4709个支架小梁,其中被内皮完全覆盖的支架小梁个数4173个(88.6%),被内皮部分覆盖的个数是33个(0.7%),暴露的小梁个数382个(8.1%);贴壁不良的小梁个数121个(2.6%),覆盖支架小梁的内膜的平均厚度是0.099mm,内膜厚度100μm的小梁个数2378个(50.5%);不同药物洗脱支架之间内膜增生厚度、支架小梁内膜覆盖及晚期支架贴壁不良差异有统计学意义;与DES植入时间12个月相比,植入时间12个月血管内膜增生厚度有明显增加趋势(0.1183mm比0.0875mm;P=0.001);支架内膜无覆盖比率分别是:1.7%比6.8%(P0.05);贴壁不良比率是:2.1%比0.5%(P0.001)。结论通过OCT分析16个月左右的药物洗脱支架血管内膜厚度,总的来说90.1%的支架小梁有内膜覆盖,但是仍然有高达9.9%的无内膜覆盖,支架类型、支架置入时间之间内膜覆盖、支架贴壁有一定差异;同时支架植入大于12个月的支架贴壁不良比率高于不足12个月的,提示更晚期的支架贴壁不良情况存在,对于药物洗脱支架的随访时间应该更长,双联抗血小板治疗疗程也许应该更长。  相似文献   

2.
目的:应用光学相干断层成像技术观察佐它莫司药物洗脱支架置入后不同时期的新生内膜覆盖和支架贴壁情况以评估血管愈合.方法:对符合标准的30例置入佐它莫司药物洗脱支架患者进行介入后即刻、介入3个月和介入9个月时的光学相干断层成像检查,每隔1 mm评估横断面影像每个支架柱的新生内膜覆盖和贴壁情况,同时观察每个支架内的血栓发生情...  相似文献   

3.
目的应用光学相干断层成像(OCT)比较西罗莫司洗脱支架(SES)与佐他莫司洗脱支架(ZES)置入后1月内新生内膜覆盖情况。方法 18只中华小型猪平均分为3组,每只猪分别在前降支和右冠状动脉随机置入SES和ZES支架各一枚,3组实验动物分别在第7天、14天、28天进行OCT检查,测量新生内膜厚度、支架内面积、管腔内面积、新生内膜面积、面积狭窄百分比和新生内膜覆盖率,比较ZES与SES置入后1月内新生内膜覆盖情况。结果 OCT测量结果显示,支架置入7天和14天时,ZES与SES两种支架丝表面新生内膜厚度和新生内膜覆盖率均存在显著统计学差异(P<0.001)。同样支架术后28天时ZES与SES支架丝表面新生内膜厚度存在显著统计学差异(244.3±282.3μmvs136.3±91.1μm,P<0.001),新生内膜覆盖率存在显著差异(94.88%±2.93%vs90.96%±4.35%,P=0.008)。结论在支架置入后1个月内,ZES与SES比较新生内膜增生更显著,支架丝表面新生内膜覆盖率更高。  相似文献   

4.
目的:应用光学相干断层成像(OCT)、病理和扫描电镜评价猪冠状动脉佐他莫司洗脱支架(ZES)术后早期(7天、14天、28天)新生内膜覆盖情况。方法:18只中华小型猪随机分为7天组、14天组和28天组,每组6只,每只猪于右冠状动脉置入一枚佐他莫司洗脱支架,3组实验动物分别于术后7天、14天及28天时进行OCT检查,观察支架表面新生内膜覆盖情况,并取支架段冠状动脉进行病理组织学检查及扫描电镜观察。结果:用OCT观察3个时间段支架表面新生内膜情况,7天组为(61.3±37.7)μm,14天组为(132.6±103.3)μm,28天组为(244.3±282.3)μm,3组间差异有统计学意义(P<0.001),新生内膜覆盖率7天组为(53.62±2.49)%,28天组达到(94.88±2.93)%,病理提示7天时新生内膜以炎性细胞、红细胞、血小板为主,28天时以平滑肌细胞、炎性细胞和血管内皮细胞为主。结论:OCT在支架术后7天即能清晰观察到新生内膜覆盖情况,佐他莫司洗脱支架术后28天大多数支架丝被新生内膜覆盖。  相似文献   

5.
目的 探讨药物洗脱支架(DES)置入术后晚期支架贴壁不良的特点.方法 分析32例(包括51支血管、共置入71个支架)置入DES 1年后[(14.8±5.2)个月]行光学相干断层成像(OCT)检查的患者资料,对支架节段的OCT图像每间隔0.5 mm取1帧图像进行分析,找出贴壁不良的支架金属结构,测量支架到参照血管内壁的距离及支架表面内膜厚度,分析晚期支架贴壁不良的特点.结果 OCT检查在7例(21.9%)患者中检出支架贴壁不良,其中4例合并支架段血管的正性重构,1例重叠置入支架,2例发现由血栓覆盖支架金属结构,7例患者随访期间无心脏不良事件发生.97.6%的支架金属结构完全贴壁并不同程度的内膜覆盖,2.4%的支架金属结构贴壁不良,包括1.2%的支架金属结构位于血管分支开口.位于血管分支开口的支架金属结构与其他贴壁不良支架表面的内膜覆盖厚度差异无统计学意义[(0.06±0.05)mm比(0.05±0.03)mm,P>0.05].绪论晚期支架贴壁不良见于DES置入最初的贴壁不良、血管壁正性重构、重叠置入支架以及支架金属结构位于分支血管开口;贴壁不良的支架金属结构表面亦有不同程度的内膜覆盖.  相似文献   

6.
目的应用光学相干断层成像(OCT)比较急性心肌梗死(AMI)患者植入不同药物洗脱支架(DES)后的新生内膜覆盖和支架贴壁情况以评估血管愈合。方法 49例AMI患者植入不同DES后9个月时进行OCT检查。其中20个雷帕霉素药物洗脱支架(SES,Cypher),12个紫杉醇药物洗脱支架(PES,Taxus)和17个雷帕霉素衍生物药物洗脱支架(ZES,Endeavor)。每隔1mm评估OCT横断面影像每个支架柱的新生内膜覆盖和贴壁情况,同时观察每个支架内的血栓发生情况。结果总计对12378个支架柱进行了分析。SES的新生内膜增生最少,新生内膜厚度:SES(77±60)μm、PES(153±82)μm、ZES(265±130)μm,且新生内膜增生面积百分比最低,SES(10±8)%、PES(19±8)%、ZES(28±9)%,但SES和PES有更多未被新生内膜覆盖的支架柱,SES(15.1±16)%、PES(7.1±10)%、ZES(0.6±1.5)%,且贴壁不良支架柱的发生率也高于ZES,SES(3.8±7.2)%、PES(2.1±4.4)%、ZES(0±0)%,而有完全新生内膜覆盖的支架比例以ZES为高,SES5%、PES33.3%、ZES82.4%。血栓的发生率SES和PES高于ZES,SES34%、PES33%、ZES6%。结论 AMI患者植入不同类型DES后,其支架的新生内膜覆盖程度和贴壁不良的发生率是显著不同的,因此DES的类型可能影响了AMI血栓性病变的血管愈合过程。  相似文献   

7.
目的 应用光学干涉断层显像(OCT)技术评价雷帕霉素洗脱支架(SES)置入后3个月和2年后内膜增殖和支架内血栓形成情况.方法 对3个月组进行SES置入后3个月的OCT随访观察,对2年组进行SES置入后2年的随访观察.测量每一个支架支撑杆表面的新生内膜厚度,并评估无内膜覆盖支架支撑杆及支架内血栓形成情况.结果 2年组的内膜厚度显著大于3个月组[(71±93)μm比(29±41)μm,P<0.01],而2年组中的无内膜覆盖支架支撑杆的比例明显低于3个月组(5%比15%,P<0.01).2年组与3个月组无内膜覆盖支撑杆患者的比例差异无统计学意义(81%比95%,P>0.05).两组中均有14%的患者出现无临床症状的支架内血栓形成.结论 SES置入后3个月到2年新生内膜的增生在不断进展,无内膜覆盖支撑杆数明显减少.但是直到支架置入后2年,多数患者体内仍然存在部分无内膜覆盖的支架支撑杆.  相似文献   

8.
目的 应用光学相干断层成像(OCT)对比不同类型药物洗脱支架(DES)置入后的内膜覆盖情况.方法 入选62例在我院置入DES(15.3±5.7)个月后行OCT检查的患者,依据置入支架类型分为Cypher支架组(病例数=26,支架数=57)、Endeavor支架组(病例数=17,支架数=23)和Firebird支架组(病...  相似文献   

9.
目的:应用光学相关断层成像(OCT)分析药物洗脱支架置入术后晚期、极晚期支架内血栓形成的可能机制。方法:入选2011-01-2017-12经遵义医学院附属医院行冠状动脉(冠脉)造影明确诊断晚期、极晚期支架内血栓形成患者8例。8例患者在PCI术中均行OCT检查。回顾性分析8例患者的临床资料、PCI过程及OCT图像特征。结果:7例伴有多个心血管危险因素,2例合并轻度左心功能不全。首次支架置入至发生支架血栓的平均时间(818±651) d;双联抗血小板服用平均时间(312.8±76.3) d;低密度脂蛋白胆固醇(LDL-C)平均水平为(3.44±1.35) mmol/L,均未达到目标值;1例在术后停用双联抗血小板3个月、2例在服用双联抗血小板期间、5例在单用阿司匹林期间发生支架内血栓;6例置入依维莫司药物支架,1例行支架内非顺应性高压球囊扩张,1例行紫杉醇药物球囊治疗。OCT图像特征:7例患者支架内异质性新生内膜形成,5例为支架内新生动脉粥样硬化伴斑块破裂,2例为支架内新生动脉粥样硬化伴斑块侵蚀;1例出现严重支架贴壁不良,贴壁不良比例达66.2%;6例患者出现不同程度的支架小梁无内膜覆盖,平均为(10.4±6.2)%;5例支架内见红血栓,3例支架内见白血栓。结论:晚期、极晚期支架内血栓患者首次及再次住院多表现为急性冠脉综合征与高LDL-C水平。支架内新生动脉粥样硬化、支架贴壁不良是导致晚期、极晚期支架内血栓形成的主要原因之一。OCT的应用有助于明确晚期和极晚期支架内血栓形成的机制。  相似文献   

10.
近年来光学相干断层成像在冠心病的研究中应用日益广泛,尤其在围支架置入期发挥了重要的作用。支架置入术前可评估斑块的特点,术后即刻评估支架的贴壁、组织损伤等,长期随访中评估血栓事件、新生内膜增生以及支架内新生斑块等。同时,光学相干断层成像在药物疗效评估及新型支架的研发中显示出其独特的优势。  相似文献   

11.
Endoscopic esophageal stent placement is widely used in the treatment of a variety of benign and malignant esophageal conditions.Self expanding metal stents(SEMS)are associated with significantly reduced stent related mortality and morbidity compared to plastic stents for treatment of esophageal conditions;however they have known complications of stent migration,stent occlusion,tumor ingrowth,stricture formation,reflux,bleeding and perforation amongst others.A rare and infrequently reported complication of SEMS is stent fracture and subsequent migration of the broken pieces.There have only been a handful of published case reports describing this problem.In this report we describe a case of a spontaneously fractured nitinol esophageal SEMS,and review the available literature on the unusual occurrence of SEMS fracture placed for benign or malignant obstruction in the esophagus.SEMS fracture could be a potentially dangerous event and should be considered in a patient having recurrent dysphagia despite successful placement of an esopha-geal SEMS.It usually requires endoscopic therapy and may unfortunately require surgery for retrieval of a distally migrated fragment.Early recognition and prompt management may be able to prevent further problems.  相似文献   

12.
Stent dislodgment during percutaneous coronary intervention is a rare complication. We report a case of successful retrieval of a deformed coronary stent through alternative transfemoral approach while performing transradial procedure when the stent could not be retrieved safely from transradial route.  相似文献   

13.
BACKGROUND: The EPISTENT trial reported improved early outcomes with routine use of abciximab after coronary stenting. Increasing use of stents means that routine abciximab adds significantly to costs of percutaneous coronary intervention (PCI). This paper reports the results of a protocol encouraging restriction therapy to high-risk patients only. METHODS: Data were collected prospectively over a 34-month period for patients undergoing PCI with stenting. In addition to those who fulfilled criteria for inclusion in the EPISTENT trial, patients treated in the setting of acute myocardial infarction (AMI) were studied. Demographic data, procedural details and early clinical outcomes were recorded. RESULTS: Of 808 patients studied, 601 fulfilled EPISTENT inclusion criteria and comprised 367 patients (45%) treated for stable angina and 234 (30%) treated for unstable or post-infarct angina. The additional 207 patients (25%) were treated during AMI. The 808 patients received a total of 981 stents. Abciximab was given in only 88 cases (10.9%). Major adverse clinical events occurred in 39 patients (4.8%). CONCLUSION: Selective use of abciximab for patients undergoing coronary stenting can be associated with outcomes equivalent to those reported for routine use, but with significant cost savings.  相似文献   

14.
A case is presented of recurrent stent thrombosis unexplained by angiographic appearance, which subsequently revealed a diagnosis of antiphospholipid syndrome secondary to renal cell carcinoma.  相似文献   

15.
经皮冠状动脉介入治疗是目前冠心病的重要治疗手段。支架置入术后再内皮化延迟与支架内再狭窄和血栓形成密切相关。随着内皮祖细胞(endothelial progenitor cells,EPC)研究的深入,EPC捕获支架诞生了。理论上其可以捕捉血液中的EPC,使其附着在支架上并分化为成熟的内皮细胞以加速局部内皮化,达到防止支架内再狭窄和血栓形成的目的。然而目前的研究发现EPC捕获支架的再狭窄率高。但是应用EPC捕获支架抗血小板治疗的时间短,对于不能坚持双联抗血小板的患者来说,EPC捕获支架有一定的优势。随着对EPC研究的不断深入及支架制作工艺的逐步提高,EPC捕获支架有希望成为冠心病治疗的又一利器。  相似文献   

16.
支架携带放射性核素能力的实验研究   总被引:5,自引:0,他引:5  
目的携带放射性核素32P的支架是实施冠状动脉(冠脉)局部放射治疗以预防再狭窄的重要方法之一。本研究采用一种新的支架包被方法,以评价其携带放射性核素的能力。方法自行研制的四种核素32P支架血浆包被32P支架、明胶包被32P支架、32P直接涂层支架、32P静脉包被支架。每种6支,均含32P胶体10μCi。置于压力为90mm?Hg的流水管中冲洗。冲洗前和冲洗后1、4、14、21d各取1支架测定放射活度。放射性包被支架制作的同时,留置5份5μCi32P胶体液作为自然衰减对照品,于1、4、7、14、21d后各取1份32P胶体液,测定其放射活度。4只犬每只犬冠脉内置入同样方法制成的血浆包被32P支架2个,于术前和术后1d、2周、7周、10周测定放射活度。3只犬冠脉内置入自体静脉包被32P支架1个,于术后1、2、3个月测定放射活度。结果流水冲洗实验示四种支架冲洗前携带32P放射活度分别为4.81、4.32、1.96、4.82μCi,冲洗21天后放射活度分别为0.33、0.12、0.01、1.34μCi,血浆和静脉包被支架时间-放射活度变化曲线接近于自然衰减曲线。冠脉置入支架实验示4条犬每只犬均成功置入血浆包被32P支架1个,术后1天、17天、7周、10周支架残留的放射活度分别为4.98、1.71、0.52、0.09、0.03μCi;3只犬中1只犬成功置入1个静脉包被32P支架,70天处死测定其放射活度为0.3μCi。结论血浆和静脉包被支架均有较好的携带核素能力,抗冲洗能力强。血浆包被支架制备简便,置入冠脉可行,置入机体可达到有效治疗剂量。  相似文献   

17.
应用小C臂X光机行经皮冠状动脉腔内成形术(附134例报告)   总被引:1,自引:0,他引:1  
目的探讨应用小C臂X光机(OEC)行经皮冠状动脉腔内成形术(PTCA)和冠状动脉内支架植入术的可行性。方法134例冠心病患者造影显示冠状动脉狭窄程度均≥75%,采用美国OEC9600型小C臂X光机行PTCA和冠状动脉内支架置入术。结果134例冠心病患者共204处病变成功地完成了PTCA,其中92例置入了106枚冠脉内支架,6例因多支冠脉病变分别置入2~3枚支架,术后冠脉造影显示管腔扩张满意,无残余狭窄。全部病例术后心绞痛症状较术前明显减轻或消失。除1例在支架置入术后发生急性血栓形成和3例出现术后穿刺部血肿外,无其它并发症发生。结论对冠心病患者应用小C臂X光机行PTCA和冠脉内支架置入术可能是一种安全有效的治疗方法。  相似文献   

18.
目的 旨在分析冠心病患者冠状动脉 (冠脉 )支架置入和单纯球囊扩张 (PTCA)后晚期冠脉内径丢失及 6个月再狭窄发生率的差异 ,证实支架置入降低再狭窄作用并探讨可能机理。方法 冠心病介入治疗 35 2例中 ,选择连续 6 5例 (86个冠脉狭窄病变 )术后 6个月随访重复冠脉造影者 ,冠脉定量分析 (QCA)术前、术后和随访复查冠脉造影图象 ,并分析随访时内径丢失与支架置入和单纯球囊扩张的关系及术后 6个月再狭窄发生率。结果 冠脉内支架置入后随访期病变血管最小内径较大 ,而绝对内径丢失、相对内径丢失、绝对管腔面积丢失和内径丢失指数均低于单纯PTCA ,支架置入组再狭窄病变内径丢失百分比小于单纯PTCA组 ;再狭窄发生和支架置入呈负相关 (RR 0 86 ,95 %CI0 6 3~ 1 16 ,P <0 0 5 ) ;6个月 41例支架置入再狭窄 12例 (2 9 3% ) ,2 4例单纯PTCA再狭窄 12例(5 0 0 % ,P =0 0 6 9) ;5 3个支架置入病变再狭窄 14个 (2 6 4% ) ,33个单纯PTCA病变再狭窄 16个(48 5 % ,P =0 0 37)。结论 国人冠心病患者冠脉内置入支架可能减少晚期冠脉再狭窄发生  相似文献   

19.
AIMS: To investigate the efficacy and outcome of emergency percutaneous coronary interventions (PCI) in patients with stent thrombosis. METHODS AND RESULTS: Between 1995 and 2003, 6058 patients underwent bare-metal stent implantation, of which 95 (1.6%) patients suffered from stent thrombosis. The timing of stent thrombosis was acute in 10 (11%), subacute in 61 (64%), and late in 24 (25%) patients. Procedural and clinical outcomes of emergency PCI for treatment of stent thrombosis were investigated. Emergency PCI was successful in 86 (91%), complicated by death in 2 (2%), and coronary artery bypass grafting in 2 (2%) patients. Myocardial infarction occurred in 77 (81%) patients with a peak creatine kinase level of 1466+/-1570 U/L. Left ventricular ejection fraction declined from 0.54+/-0.19 prior to 0.48+/-0.16 (P<0.05) at the time of stent thrombosis after emergency PCI. A 6 month major adverse clinical events comprised death (11%), reinfarction (16%), and recurrent stent thrombosis (12%) after emergency PCI. Multivariable logistic regression analysis identified the achievement of TIMI 3 flow (OR=0.1, CI 95% 0.01-0.54, P<0.001) and diameter stenosis <50% (OR=0.06, CI 95% 0.01-0.32, P<0.001) during emergency PCI to be independently associated with a reduced risk of cardiac death. Recurrent stent thrombosis was independently predicted by the omission of abciximab (OR=4.3, CI 95% 1.1-17.5). CONCLUSION: Emergency PCI for treatment of stent thrombosis effectively restores vessel patency and flow. Patients presenting with stent thrombosis are at risk for recurrent myocardial infarction and recurrent stent thrombosis.  相似文献   

20.
目的:比较Excel药物洗脱支架和Firebird 2TM药物洗脱支架在冠心病患者中应用的近期疗效。方法:将2009年12月至2010年9月,在安贞医院连续住院的264例原位冠状动脉病变的患者,纳入本项前瞻性随机对照研究。其中137例仅置入Firebird 2TM药物洗脱支架,127例仅置入Excel药物洗脱支架。规律随访患者,比较2组患者支架术后的心脏不良事件发生率。随访的具体内容包括主要终点事件(全因死亡、靶血管血运重建、非致死性心肌梗死、血栓事件)和次要终点事件(不稳定心绞痛、缺血性脑卒中及心功能衰竭)。分析支架多聚物涂层对心脏不良事件的影响。结果:2组患者年龄、性别、吸烟史、高血压、脂质异常、糖尿病、既往介入治疗、既往心肌梗死、既往冠状动脉旁路手术及本次入院诊断急性心肌梗死所占比例方面差异均无统计学意义。Firebird 2TM药物洗脱支架组患者平均支架个数较Excel药物洗脱支架组个数分别为(1.93±1.13)个和(1.57±0.94)个。临床随访1.84~10.78个月,平均(5.36±1.91)个月,2组患者均未发生心源性死亡、靶病变血管导致的心肌梗死、靶病变缺血导致的血运重建及支架血栓事件。Firebird 2TM药物洗脱支架组患者不稳定心绞痛1例,心力衰竭(心衰)1例,Excel药物洗脱支架组,不稳定心绞痛3例,心衰1例,Kaplan-Meier生存曲线显示2组患者全部终点事件没有差别。结论:Firebird 2TM药物洗脱支架和Excel药物洗脱支架,在冠心病患者中应用的近期安全性方面疗效相似。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号