Stereotactic breast biopsy: recumbent biopsy using add-on upright equipment   总被引:2,自引:0,他引:2  
OBJECTIVE: The purpose of the study was to show that stereotactic breast biopsy can be performed effectively and accurately using add-on stereotactic equipment when it is performed with the patient in a decubitus or recumbent position. MATERIALS AND METHODS: We retrospectively reviewed the results of 225 stereotactic core breast biopsies performed during a 42-month period. The biopsies were performed using a reclining mammography chair and add-on stereotactic equipment. Procedures were performed with the patient in the right or left lateral decubitus position or upright. Patients with benign biopsy results were followed up mammographically at 6 months initially, then yearly. RESULTS: Of the 225 lesions biopsied stereotactically, 205 lesions (91%) were biopsied with the patient in the decubitus (right or left) position and 20 (9%) biopsied with the patient upright. Pathology results were classified as abnormal in 45 lesions (20%) and normal in 180 lesions (80%). All but one of the abnormal lesions were followed up with surgical excision. One hundred thirty-four of the 180 benign lesions have been followed up with at least one 6-month mammogram (follow-up range, 6-40 months), and none of the lesions has been subsequently proven malignant. CONCLUSION: Stereotactic core biopsy can be performed effectively and accurately using standard add-on equipment when it is performed with the patient in the decubitus position. This approach obviates the use of dedicated prone stereotactic equipment.  相似文献   

2.
AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS.  相似文献   

3.
OBJECTIVE: The purpose of this prospective study was to assess the accuracy of an add-on stereotactic unit for core needle biopsy of mammographic lesions. SUBJECTS AND METHODS. Between September 1994 and February 2001, 506 stereotactic core needle biopsies of mammographic lesions in 492 patients were performed in our center on a mammography unit with add-on stereotactic equipment. Of the initial 92 patients, 80 underwent stereotactic core needle biopsy and surgical excision simultaneously. In subsequent cases, surgical biopsy was performed after core biopsy in patients who had malignant or atypical histologic results or discordance between mammographic and pathologic findings. Follow-up mammography was advised for all patients whose core biopsy results were diagnosed as benign lesions. RESULTS: Histologic results for 506 lesions undergoing stereotactic core needle biopsy were as follows: 113 (22.3%) were malignant; 369 (72.9%), benign; and 24 (4.7%), atypical. Of 113 malignant lesions identified at stereotactic core needle biopsy, 111 were confirmed as malignant, whereas two showed no evidence of malignancy at surgical excision. Of 369 lesions diagnosed as benign at stereotactic core needle biopsy, 172 (46.6%) showed no change on follow-up mammography, 114 (30.9%) were lost to follow-up, and 83 (22%) underwent surgical excision. Of 24 lesions with atypical histology, 23 had surgical follow-up, six were malignant, nine were benign, and eight were confirmed as showing atypical histology. Stereotactic core needle biopsy of the 506 lesions was complicated by five (1.0%) cases of vasovagal attack and four (0.8%) cases of bleeding. The resulting sensitivity, specificity, and positive and negative predictive values were 98.3%, 93.0%, 86.0%, and 99.2% respectively. CONCLUSION: Biopsy with an add-on unit is safe, reliable, accurate, and cost-effective with results comparable to those reported for dedicated prone biopsy devices.  相似文献   

4.
PURPOSE: To retrospectively determine the frequency and causes of failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph of the specimen, and to determine outcome in patients with those lesions. MATERIALS AND METHODS: Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted a waiver of informed consent. Retrospective review was performed of 1701 consecutive nonpalpable microcalcification lesions in 1511 women aged 29-92 years (median age, 54 years) who underwent percutaneous stereotactic biopsy on a prone biopsy table. Biopsy was successively performed with 14-gauge core, 14-gauge vacuum, and 11-gauge vacuum devices, with mild selection bias, and for each lesion, biopsy was performed with one device. Radiographs of the specimen were obtained to see whether microcalcifications were retrieved. Patient, mammographic, and biopsy variables were correlated with negative radiographs of the specimen. At repeat biopsy or mammographic follow-up, outcome was evaluated in patients with benign histologic results and negative radiographs of the specimen by using Fisher exact test P values. RESULTS: Radiographs of the specimen were negative in 16% (30 of 182) of lesions at 14-gauge core biopsy, in 4% (four of 96) of lesions at 14-gauge vacuum biopsy, and in 1% (19 of 1423) of lesions at 11-gauge vacuum biopsy (P < .001). Substantial bleeding was a significant factor (P < .001) in failure to retrieve microcalcifications at only 11-gauge vacuum biopsy. Histologic results in 53 lesions with negative radiographs of the specimen were malignant (n = 6), indicated atypical hyperplasia (n = 6), or were benign (n = 41). Follow-up in patients with 40 benign lesions was performed with repeat biopsy (n = 17, with malignancy in three lesions) or mammography (n = 23) for 15-128 months (median, 70 months); one patient with one lesion was lost to follow-up. CONCLUSION: Failure to retrieve microcalcifications was least common with 11-gauge directional vacuum-assisted biopsy and occurred in 1% (19 of 1423) of lesions. Cancer was missed in 8% (three of 40) of benign lesions in patients who were followed up.  相似文献   

5.
OBJECTIVE: To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. PATIENTS AND METHODS: During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenoma, fibrocystic change, normal or other. RESULTS: The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (kappa = 0.88), and there was 97% agreement (kappa = 0.94) for the classification of cancer versus benign lesion. CONCLUSION: The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment.  相似文献   

6.
OBJECTIVE: The purpose of this study was to compare the usefulness of, and cost of diagnosing with, different breast biopsy methods for women with calcifications highly suggestive of malignancy. MATERIALS AND METHODS: One hundred thirty-nine women with calcifications highly suggestive of malignancy underwent diagnostic biopsy. Of these, 89 women had stereotactic biopsy with a 14-gauge automated needle (n = 25), 14-gauge vacuum-assisted probe (n = 17), or 11-gauge vacuum-assisted probe (n = 47); and 50 women had diagnostic surgical biopsy. Medical records were reviewed. Cost savings for stereotactic biopsy were calculated using Medicare data. RESULTS: The median number of operations was one for women who had stereotactic biopsy versus two for women who had diagnostic surgical biopsy. The likelihood of undergoing a single operation was significantly greater for women who had stereotactic rather than surgical biopsy, among all women (61/89 [68.5%] vs. 19/50 [38.0%], p < 0.001) and among women treated for breast cancer (55/77 [71.4%] vs. 6/37 [16.2%], p = 0.0000001). Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, was significantly more likely to spare a surgical procedure (36/47 [76.6%] vs. 16/42 [38.1%], p = 0.0005). Stereotactic 11-gauge vacuum-assisted biopsy resulted in the greatest cost reduction, yielding savings of $315 per case compared with diagnostic surgical biopsy; for women with solitary lesions, stereotactic 11-gauge biopsy decreased the cost of diagnosis by 22.2% ($334/$1502). CONCLUSION: For women with calcifications highly suggestive of malignancy, the use of stereotactic rather than surgical biopsy decreases the number of operations. Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, is significantly more likely to spare a surgical procedure and has the highest cost savings.  相似文献   

7.
This study was carried out to compare the efficacy of 14 vs 12 G needles in stereotactic core biopsy of mammographic calcification. A consecutive series of 100 impalpable mammographic calcifications, without an associated mass and requiring stereotactic core biopsy were randomly allocated to either 14 G or 12 G needle sampling. All biopsies were performed using an upright stereotactic digital unit (Senovision GE) and a Bard automated biopsy gun. Core biopsy results were categorized as either normal, benign, atypical ductal hyperplasia, suspicious of ductal carcinoma in situ (DCIS), DCIS or invasive cancer. The radiographic calcification retrieval rates, complete and absolute sensitivity for malignancy of DCIS and DCIS with an invasive focus were obtained by comparison of core results with surgical histology. Radiographic calcification retrieval was achieved in 86% when using 14 G and 12 G needles. The absolute sensitivity and complete sensitivity for diagnosing DCIS were the same with 12 G and 14 G needles (72% versus 71% and 93% versus 94%, respectively). The use of 12 G needles does not appear to confer benefit over the use of 14 G needles in the diagnosis of mammographic calcification.  相似文献   

8.
Soo MS  Ghate S  Delong D 《Clinical imaging》1999,23(6):469-352
The purpose of this study was to evaluate the stereotactic 14-gauge, vacuum-assisted biopsy technique in diagnosing noncalcified breast lesions. Stereotactic biopsy of 116 noncalcified breast lesions was performed with either 14-gauge, vacuum-assisted technique or multipass, automated large-core technique. The number of core samples and time required for each biopsy were compared. Outcome for each technique was compared based on recommendations after the mammographic-histologic review process. Results from surgical excision and mammographic follow-up were reviewed. The vacuum-assisted technique obtained more tissue cores per lesion than the automated gun technique, showed marginal decrease in number of repeat biopsies for discordant results, and required fewer short-term follow-up mammograms, although the difference did not achieve statistical significance. The vacuum-assisted technique can be used successfully to sample noncalcified breast masses, with marginal improvement over the automated gun technique.  相似文献   

9.
OBJECTIVE: We compared complication rates of core needle breast biopsy in patients with and without concurrent anticoagulation therapy. SUBJECTS AND METHODS: Experience with 501 14-gauge and 179 11-gauge core needle breast biopsies was recorded prospectively. We performed 18 (3%) of 680 procedures on patients undergoing anticoagulation therapy. Eleven biopsies were performed in eight women treated with warfarin, one in a patient treated with heparin, and six in six women treated with aspirin. Ten biopsies were performed with sonographic guidance and a 14-gauge automated biopsy gun. Eight biopsies were performed with an 11-gauge vacuum-assisted probe and stereotactic guidance. RESULTS: Hematomas occurred in three (38%) of eight anticoagulated patients undergoing 11-gauge vacuum-assisted stereotactic biopsy, measuring 13 mm, 17 mm, and 40 mm. In patients not known to be anticoagulated, small hematomas were mammographically evident in 77 (45%) of 171 biopsies performed with an 11-gauge probe, averaging 8 mm (range, 2-17 mm); only 13 (8%) of 171 had hematomas larger than 10 mm. Small hematomas, averaging 6 mm (range, 2-12 mm) were evident mammographically in 45 (45%) of 100 stereotactic biopsies using a 14-gauge automated biopsy gun; three (3%) experienced hematomas larger than 10 mm. A 10-mm hematoma was evident during one (10%) of the 10 biopsies performed in patients undergoing anticoagulation therapy under sonographic guidance using a 14-gauge automated biopsy gun; small hematomas (mean, 10 mm) were noted during seven (2%) of 391 corresponding sonographically guided biopsies in patients not undergoing anticoagulation therapy. CONCLUSION: No patients undergoing anticoagulation therapy experienced clinically important complications; preliminary results suggest rates of hematoma formation similar to those in the control group. As such, discontinuing anticoagulation medication before core needle breast biopsy may be unnecessary when the need for biopsy is urgent.  相似文献   

10.
OBJECTIVE: The purpose of our study was to evaluate how often a mammographic abnormality thought to be produced by the biopsy procedure was evident on the initial follow-up mammogram after percutaneous biopsy of impalpable histologically benign lesions. We compared three stereotactic percutaneous biopsy methods. CONCLUSION: A mammographic density seen well only in the projection parallel to the biopsy needle tract was evident in 2% (5/226) of the lesions for which 11-gauge directional vacuum-assisted biopsy was used, 0% (0/96) of the lesions for which 14-gauge directional vacuum-assisted biopsy was used, and 0% (0/422) of the lesions for which 14-gauge automated large-core biopsy was used. No mammographic abnormalities assessed as BI-RADS categories 3, 4, or 5 (according to the American College of Radiology's Breast Imaging Reporting and Data System) and thought to be produced by the biopsy procedure were evident after any of the biopsy methods.  相似文献   

11.
OBJECTIVE: To demonstrate the reliability of stereotaxic biopsy of indeterminate microcalcifications using a standard mammography table with an add-on unit. METHODS: In 121 cases of indeterminate microcalcifications, core biopsy was performed using a standard mammography table with an add-on stereotaxic unit. Microcalcifications were identified on radiography of core specimens. RESULTS: Microcalcifications and a definitive histologic diagnosis were obtained in 112 core biopsies (92.6%), with no significant complications. In 23 lesions frank malignancy was diagnosed, and all of these diagnoses were confirmed on surgery. Pathologic examination suggested carcinoma in 4 lesions, and open biopsy confirmed malignancy in 3 of these cases. Four lesions showed atypical ductal hyperplasia. Benign disease was diagnosed in 81 lesions, of which 78 remained stable on mammographic follow-up (mean 16 months later) and 3 were subjected to surgical biopsy (of which 1 was malignant and 2 were benign). Nine cases were technically unsatisfactory because microcalcifications were not sampled. CONCLUSION: Stereotaxic core biopsy performed with an add-on unit is a safe and reliable technique for biopsy of indeterminate microcalcifications. For successful biopsy, microcalcifications must be harvested. Pathologic results should be correlated with mammographic findings. The accuracy rate compares favourably with results reported using prone biopsy tables. In an era of cost containment, this alternative to prone biopsy tables could result in significant savings in terms of capital investment and use of hospital rooms. In this study, surgical biopsy could have been avoided in 64.5% of cases.  相似文献   

12.
Learning curve for stereotactic breast biopsy: how many cases are enough?   总被引:5,自引:0,他引:5  
OBJECTIVE: The objective of this study was to evaluate the learning curve for stereotactic breast biopsy. MATERIALS AND METHODS: Retrospective review was performed of 923 consecutive lesions that underwent stereotactic breast biopsy performed by one of six radiologists. Four hundred fourteen lesions had 14-gauge automated core biopsy, and 509 subsequent lesions had vacuum-assisted biopsy (14-gauge in 163 and 11-gauge in 346). Medical records were reviewed to determine the technical success rate and false-negative rate as a function of operator experience. RESULTS: For 14-gauge automated core biopsy, a significantly lower technical success rate was seen for the first five cases of each radiologist than for subsequent cases (25/30 = 83.3% versus 366/384 = 95.3%, p < 0.02) and for the first 20 cases than for subsequent cases (90/100 = 90% versus 284/296 = 95.9%, p < 0.05). For 11-gauge vacuum-assisted biopsy, a significantly lower technical success rate was seen for the first five cases than for subsequent cases (17/20 = 85.0% versus 310/322 = 96.3%, p < 0.05) and for the first 15 cases than for subsequent cases (54/60 = 90.0% versus 273/283 = 96.5%, p = 0.03). The false-negative rate was higher for the first 15 cases compared with subsequent cases both for stereotactic 14-gauge automated core biopsy (4/31 = 12.9% versus 3/115 = 2.6%, p < 0.04) and for stereotactic 11-gauge vacuum-assisted biopsy (2/27 = 7.4% versus 0/85 = 0%, p < 0.06). CONCLUSION: A learning curve exists for stereotactic breast biopsy. Significantly higher technical success rates and lower false-negative rates were observed after the first five to 20 cases for 14-gauge automated core biopsy and after the first five to 15 cases for 11-gauge vacuum-assisted biopsy. Even after a radiologist has experience with stereotactic biopsy, changes in equipment may result in a new learning curve.  相似文献   

13.
Purpose:
To assess the usefulness of stereotactic vacuum-assisted core breast biopsy (VCBB) performed using a stereotactic add-on device and film-screen technology with the patient in an upright seated position. Material and Methods:
We reviewed a series of 129 women with non-palpable mammographic abnormalities who required stereotactic VCBB from December 1999 to November 2000. Twenty-seven (20.9%) cases were excluded due to difficulties in keeping the correct position during the procedure, while the other 102 (79.1%) underwent successful VCBB. Patients with lesions consisting of either atypical ductal hyperplasia or lobular carcinoma in situ were considered for excisional biopsy. Patients with either ductal carcinoma in situ or infiltrating breast cancer were referred for definitive surgery. The results of stereotactic VCBB were correlated to the subsequent surgical histology. Results:
Stereotactic VCBB was interrupted because of bleeding in 1 case and vasovagal reaction in 5 cases. Two haematomas occurred after the procedure. Overall underestimation rate was 10.5%. No new lesions were discovered after a mean follow-up of 18.7 months. Conclusion:
Stereotactic VCBB performed using a standard add-on device with the patient in an upright seated position and analog technology is feasible in about 80% of cases, has a low complication rate, is not significantly time-consuming, and can offer the same accuracy as dedicated prone equipment.  相似文献   

14.
OBJECTIVE: The purpose of this study was to evaluate imaging-guided vacuum-assisted mammotome biopsy as a minimally invasive method of obtaining a satisfactory diagnosis and eliminating the bothersome symptoms in patients presenting with nipple discharge. MATERIALS AND METHODS: Forty-nine women who presented with nipple discharge and who had final pathologic diagnoses of papillary lesions were retrospectively identified. Fifty-six lesions were biopsied in this group. The examinations included mammography, ductography, sonography, and, if possible, percutaneous biopsy. All lesions were centrally located and most were superficial. Of this study group, four patients with five lesions proceeded to sonographically guided automated core biopsy, and 38 patients with 44 intraductal lesions identified by sonography advanced to sonographically guided biopsy with an 11-gauge mammotome probe. One patient underwent stereotactic 11-gauge mammotome biopsy. Patients not advancing to sonographically guided biopsy were those with masses either in the nipple or nipple-areolar complex (five patients), one patient with no identifiable lesion at sonography, and one directly referred for open surgical biopsy. RESULTS: In all biopsied patients, satisfactory tissue for diagnosis was obtained. In patients biopsied with the mammotome probe, follow-up at a mean time of 13 months revealed resolution of the presenting problematic discharge in 97.2% of patients. Complications were mild and infrequent. Only one of 50 percutaneously biopsied lesions was not benign and required subsequent surgery. CONCLUSION: Papilloma excision with percutaneous biopsy allows safe and accurate tissue analysis and a high probability of terminating the symptomatic nipple discharge.  相似文献   

15.
OBJECTIVE: The goal of this study was to assess the accuracy of an add-on stereotactic unit for core biopsy of indeterminate breast microcalcifications and to compare digital with conventional stereotactic guidance. MATERIALS AND METHODS: We conducted a retrospective review of 232 lesions with indeterminate microcalcifications in 218 women who underwent stereotactically guided breast biopsies. All biopsies were performed using a standard mammography machine with an add-on unit, 121 with conventional and 111 with digital stereotactic guidance. Successful sampling of the lesion was determined by the detection of microcalcifications on specimen radiography or at pathology. RESULTS: Using the add-on unit, 219 (94.4%) of the 232 targeted lesions were successfully sampled. The size, location, number of cores per lesion, and histology of the lesions were not different between the conventional and digital stereotactic biopsy groups (p > 0.1). Indeterminate microcalcifications were missed on biopsy in nine (7.4%) of 121 cases using conventional radiography and in only four (3.6%) of 111 cases using digital imaging. Digital stereotactic guidance allowed sampling of lesions with fewer calcifications per square centimeter (p < 0.001). CONCLUSION: Sampling of indeterminate microcalcifications using a standard mammography machine and an add-on unit has a high accuracy, similar to rates reported for dedicated prone biopsy tables. An add-on unit offers the advantage of considerable cost and space savings. Relative to conventional radiography, digital stereotactic guidance allows lesions with fewer calcifications to be sampled and achieves a greater biopsy success rate. Immediate digital images in the biopsy room also permit rapid adjustment of alignment and minimize patient movement.  相似文献   

16.
OBJECTIVE: The purpose of this retrospective study was to determine which mammographically detected lesions in need of imaging-guided biopsy could undergo prone, stereotactic biopsy. MATERIALS AND METHODS: From July 1991 through June 2001, 1687 consecutive patients (age range, 29-94 years; median age, 58 years) with 1894 lesions were referred by clinicians in a multispecialty clinic. The patients underwent stereotactic, prone, histologic biopsy of 1851 lesions (98%) and needle-localized breast biopsy of 43 lesions (2%). We performed stereotactic biopsies successively with 14-gauge automated large-core devices and 14- or 11-gauge vacuum-assisted devices. We evaluated lesions by patient, breast, lesion, and procedural variables to determine why stereotactic biopsy was not performed. RESULTS: Of 1851 lesions referred for stereotactic biopsy, biopsies were canceled in 42 lesions (2%) not considered suspicious enough to warrant biopsy. Of 1809 lesions in which stereotactic biopsy was considered to be warranted, stereotactic biopsy was canceled for technical reasons in 29 lesions (2%). Of 43 lesions referred for surgical biopsy, stereotactic biopsy was thought to be technically problematic in five (12%). Inability to accomplish a stereotactic biopsy in 34 (2%) of 1852 lesions needing a biopsy was due to proximity to the chest wall (n = 10, 29%), inadequate lesion visualization unrelated to lesion depth (n = 19, 56%), and patient factors (n = 5, 15%). CONCLUSION: Stereotactic biopsy had a technical success rate of 98% (1780/1809) and was used for histologic diagnosis in 96% (1780/1852) of mammographically detected lesions. Inadequate lesion visualization accounted for 85% (29/34) of stereotactic biopsy failures.  相似文献   

17.
A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive.  相似文献   

18.
OBJECTIVE: The purpose of this study was to compare the diagnostic accuracy of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy techniques in the diagnosis of ductal carcinoma in situ of the breast. MATERIALS AND METHODS: We retrospectively reviewed 41 consecutive lesions that had been diagnosed as ductal carcinoma in situ using stereotactic needle biopsy. The first 21 lesions had been biopsied using a 14-gauge automated gun; the remaining 20 lesions, using an 11-gauge vacuum-assisted device. Surgical histopathologic results at lumpectomy were compared with the findings at needle biopsy and defined as either concordant, when only ductal carcinoma in situ (i.e., no evidence of invasive carcinoma) was evident at surgery, or discordant, when invasive carcinoma was found. One patient from the automated gun group was lost to follow-up and was not included in the analysis. RESULTS: Invasive carcinoma was found at surgery in seven (35%) of the 20 cases diagnosed using the automated gun compared with three (15%) of the 20 cases diagnosed using the vacuum-assisted device (p = .13). In all three of these discordant vacuum-assisted cases, only microinvasive disease was found at surgery. However, in only two of the seven discordant automated gun cases was only microinvasive disease found at surgery. CONCLUSION: The 11-gauge directional vacuum-assisted biopsy technique may improve the accuracy of ductal carcinoma in situ diagnosis. Underestimation of disease still occurs, however.  相似文献   

19.
Stereotactic breast biopsy with a biopsy gun   总被引:37,自引:1,他引:36  
One hundred three patients underwent stereotactic breast biopsy with an 18-, 16-, or 14-gauge cutting needle and a biopsy gun. After biopsy, a localization wire was placed and surgical biopsy performed. There was agreement of the histologic results in 89 cases (87%) including 14 of 16 cancers (87%) (kappa = 0.806). The gun biopsy yielded the correct diagnosis in four cases involving a lesion (including one cancer) that was missed at the surgical biopsy. Nine cases in which the lesion was missed at gun biopsy can be related to insufficient needle size, the greater difficulty in using one of the two stereotactic devices, and early inexperience with the technique. A 14-gauge needle was used in the last 29 biopsies, the results of which agreed with the surgical pathologic findings in 28 cases (97%). With greater experience, stereotactic-guided large-gauge automated percutaneous biopsy may prove to be an acceptable alternative to surgical biopsy in women with breast masses suspected at mammography.  相似文献   

20.
Underestimation of breast cancer with II-gauge vacuum suction biopsy   总被引:2,自引:0,他引:2  
OBJECTIVE. The purpose of this study was to determine the mammographic and histologic features of cancerous lesions underestimated using 11-gauge vacuum suction biopsy. MATERIALS AND METHODS. Retrospective review of 11-gauge vacuum suction biopsy was performed to identify lesions diagnosed as atypical ductal hyperplasia or carcinoma. The histology of the core and surgical specimens was compared. Of 158 cases of cancer, underestimation occurred in 15 (9.5%). The mammographic and histologic features were assessed. RESULTS. Of 15 underestimated cases, six were atypical ductal hyperplasia that proved to be cancer (5 ductal carcinoma in situ and 1 invasive) and nine were ductal carcinoma in situ that proved to have invasion. The underestimation rate for calcifications was 16.3% (14/86) and for masses was 1.6% (1/64) (p = 0.007). Most (5/6) underestimated atypical ductal hyperplasia cases were reported as "markedly atypical," and four of nine underestimated ductal carcinoma in situ cases were reported as "possible invasion." No significant difference was seen in the number of core specimens obtained or the sizes of the lesions for underestimated cases versus accurately diagnosed cases. The percentage of calcifications retrieved was significantly different (p = 0.017). No underestimations were found among cases in which the entire mammographic lesion was removed at vacuum suction biopsy. CONCLUSION. The cancer underestimation rate with vacuum suction biopsy was 9.5%. The underestimation rate for calcifications (16.3%) was significantly higher than that for masses (1.6%) (p = 0.007). The percentage of the lesion removed was an important factor in reducing underestimation, as reflected by the percentage of calcifications retrieved and the instances of complete resolution of the lesion seen on mammography.  相似文献   