首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Gd-DTPA in clinical MR of the brain: 1. Intraaxial lesions   总被引:2,自引:0,他引:2  
Over 35 intraaxial lesions in 15 patients suspected of having intracranial tumors were studied with MR before and after injection of Gadolinium-DTPA (Gd-DTPA). Diseases included primary and metastatic brain tumors, plaques of multiple sclerosis, occult arteriovenous malformations, lymphoma, toxoplasmosis, and pituitary adenoma. The precontrast T2-weighted sequence (SE 2000/30, 60) was found to be most sensitive in detecting intraaxial lesions, showing 17 lesions that were not seen on the post-Gd-DTPA T1-weighted sequence (SE 500/30). In one case of multiple sclerosis, several lesions seen on the pre-Gd-DTPA study on T2-weighted images faded after injection of Gd-DTPA (due to T2 shortening). In two patients with large metastatic foci, other small metastatic lesions were seen better after Gd-DTPA on both T1- and T2-weighted sequences. Four other patients with only one focal-enhancing lesion and one patient with multifocal lesions on T1-weighted images actually had a much larger single glioma depicted on pre-Gd-DTPA T2-weighted images. In a patient with AIDS, a ring-enhancing lesion thought to be an abscess proved to be lymphoma. The cryptic arteriovenous malformations enhanced but showed more characteristic findings, such as hemorrhage, on pre-Gd-DTPA studies. Our experience suggests that Gd-DTPA may not improve sensitivity of MR in the detection of intraaxial lesions. However, functional aspects of brain disease, such as the presence of perfusion of a lesion and active breach of the blood-brain barrier, are depicted well with Gd-DTPA and are vital for proper diagnosis in many instances.  相似文献   

2.
The aim of this study was to correlate MR imaging and operative findings of hemorrhage in pituitary macroadenomas. We retrospectively reviewed MR images of 113 surgically proven pituitary adenomas. All patients were examined on a 1.5-T MR system. The intensity of intratumoral cystic cavities was correlated with operative findings. In 15 patients with pituitary apoplexy, we determined relationship between interval of MR examination after apoplectic event and MR signal intensity. In 8 patients with repeated preoperative MR examination, we evaluated sequential changes of intratumoral hemorrhage. There were 54 cavities at surgery: 52 were hemorrhagic and 2 were nonhemorrhagic. Twenty-nine of 52 hemorrhagic cysts demonstrated high/low signal (H/L) fluid–fluid levels on T2-weighted image (T2WI). In 19 of them, two components could be separately seen at operation: the supernatant high-intensity area represented xanthochromic fluid, and the dependent low-intensity area represented liquefied hematoma. The H/L fluid–fluid level was observed predominantly in hematomas on MR images obtained after longer intervals. In patients with repeated MR examination, follow-up MR imaging revealed additional hemorrhage or new formation of fluid–fluid levels. It was surprising that 12 of 14 cysts preoperatively judged as nonhemorrhagic in fact contained hemorrhagic components. The preoperative MR images are well correlated to the operative findings in hemorrhagic pituitary macroadenomas. It proved that 52 of 54 cystic cavities had hemorrhagic component. Received 1 July 1997; Revision received 12 November 1997; Accepted 9 December 1997  相似文献   

3.
We report a Rathke's cleft cyst which presented as pituitary apoplexy, a rare presentation. A 46-year-old woman suffered sudden headache and visual loss. T1-weighted MRI 3 weeks after this apoplectic episode demonstrated a cystic lesion between the anterior and posterior lobes of the pituitary, with some high-signal material layering in it. The mass showed spontaneous regression on an image 3 weeks later. Trans-sphenoidal surgery confirmed the diagnosis of a Rathke's cleft cyst with a haematoma within it. Received: 30 September 1998 Accepted: 5 February 1999  相似文献   

4.
Wernicke encephalopathy: MR findings in two patients   总被引:3,自引:0,他引:3  
Wernicke encephalopathy is a serious neurologic disorder caused by vitamin-B1 or thiamine deficiency. In the literature the characteristic symmetric paraventricular lesions of Wernicke encephalopathy are hyperintense on T2-weighted sequences spin-echo (SE) and enhance on T1-weighted SE sequences after intravenous gadolinium administration in the acute phase. We present two patients in the acute phase of Wernicke encephalopathy with special reference to the MR imaging. One of our reported cases is special because of the MR demonstration of a hemorrhagic focus in the caput of the right nucleus caudatus. The other case demonstrates no enhancement on SE T1-weighted sequences after intravenous gadolinium administration. Received: 1 July 1998; Revision received: 19 January 1998; Accepted: 20 January 1998  相似文献   

5.
PURPOSE: To determine the sensitivity and specificity of magnetic resonance (MR) imaging for depicting pancreatic small, functional islet cell tumors and the minimum number of sequences for expedient diagnosis. MATERIALS AND METHODS: Twenty-eight patients clinically suspected to have functional islet cell tumors underwent T1- and T2-weighted spin-echo (SE) MR imaging with and without fat suppression, T2-weighted fast SE imaging, and spoiled gradient-echo (GRE) imaging before and after injection of gadopentetate dimeglumine. Sensitivity, specificity, and the best and minimum number of sequences for definitive diagnosis were determined. RESULTS: MR images depicted proved islet cell tumors in 17 of 20 patients (sensitivity, 85%). Images were true-negative in eight patients with negative follow-up examination results for more than 1 year. Specificity was 100%; positive predictive value, 100%; and negative predictive value, 73%. Among 20 patients with tumor, T1-weighted SE images with fat suppression and nonenhanced spoiled GRE images each showed lesions in 15 (75%); T2-weighted conventional SE with fat suppression, in 13 (65%); gadolinium-enhanced spoiled GRE, in 12 (60%); and T2-weighted fast SE, in seven of 10 patients (70%). CONCLUSION: MR imaging accurately depicts small islet cell tumors. T2-weighted fast SE and spoiled GRE sequences usually suffice. Gadolinium-enhanced sequences are needed only if MR imaging results are equivocal or negative.  相似文献   

6.
目的:评价不同的频率编码方向对于垂体微腺瘤3.0T MR图像质量的影响,以指导该病MRI参数的选择。方法:选取14例临床拟诊为垂体微腺瘤患者,使用3.0T MR扫描仪分别于垂直频率编码方向(上/下)和水平频率编码方向(左/右)上行冠状面T1WI、T2WI及T1WI增强扫描。由两位神经放射学专家按照一个5级评分标准对所得图像进行评分。评分标准如下:能极好地显示瘤体,4分;足够用于诊断,3分;能用于诊断,2分;不能用于诊断,1分;无阳性发现,0分。将两位专家对每组的评分取平均数作为最终评分,两组间评分的比较采用配对样本的符号秩和检验。结果:除2例患者在两组图像中均无阳性发现外,其余12例患者均被诊断为垂体微腺瘤。对于T2WI平扫图像和T1WI增强图像,左/右频率编码方向所获得图像质量优于上/下频率编码方向所获得图像,且二者差异具有统计学意义(P<0.05)。对于T1WI平扫图像,二者差异无统计学意义(P>0.05)。结论:使用3.0T MR扫描仪进行垂体微腺瘤成像,频率编码方向对T2WI平扫图像和T1WI增强图像质量影响较大,水平(左/右)频率编码方向扫描所得图像的质量比垂直(上/下)频率编码方向扫描所得图像质量更佳。  相似文献   

7.
Magnetic resonance imaging of pituitary adenomas   总被引:2,自引:2,他引:0  
Today, MR is the only method needed for the morphological investigation of endocrine-active pituitary adenomas. In acromegaly and Cushings syndrome, the therapeutic attitude is directly dictated by MR data. We present the MR aspect of pituitary adenomas according to size, sex, age, endocrine activity and a few particular conditions such as hemorrhagic pituitary adenomas, pituitary adenomas during pregnancy, cavernous sinus invasion and postsurgical changes. When an intrasellar mass extending out of the sella turcica is detected, the goal of the MR examination is to indicate precisely the origin of the tumor, its extension in relation to the various surrounding structures, its structure and its enhancement in order to help in the differential diagnosis. Demonstration of very small pituitary adenomas remains a challenge. When SE T1- and Turbo SE T2-weighted sequences are non-diagnostic, enhanced imaging becomes mandatory; half-dose gadolinium injection, delayed sequence, dynamic imaging can be of some help.  相似文献   

8.
The aim of this study was to assess the efficacy of a superparamagnetic iron oxide, ferumoxides, in the detection and characterization of focal nodular hyperplasia (FNH) on MR conventional spin-echo (SE), fast spin-echo (FSE) and gradient-echo (GRE) images. Fourteen adults with 27 FNHs were evaluated at 1.5 T before and after injection of ferumoxides. T1-weighted and T2-weighted SE, T2-weighted FSE and T2*-weighted GRE sequences were used and analysed qualitatively and quantitatively. One hundred percent of FNHs showed a significant postcontrast decrease in signal intensity on T2- and T2*-weighted images. Heavily T2-weighted SE images showed the maximum decrease in FNH signal-to-noise ratio (S/N). Postcontrast GRE T2*-weighted images improved the detection of the central scar and the delineation of FNHs and demonstrated the best lesion-to-liver contrast-to-noise ratio (C/N). Postcontrast T1-weighted SE images showed the least lesion-to-liver C/N. Ferumoxides-enhanced MR imaging can help detect and characterize FNH. Conventional pre- and postcontrast T2-weighted SE images and postcontrast GRE T2*-weighted images should be used preferentially. Received: 30 November 1998; Revised: 5 April 1999; Accepted: 6 April 1999  相似文献   

9.
The objective of this study was to compare the accuracy of T2-weighted fast-spin-echo (FSE) and intermediate-weighted spin-echo (SE) MR imaging in the detection of meniscal tears. Seventy-six patients (152 menisci) who had arthroscopic surgery after MR imaging of the knee were studied. MR imaging included intermediate-weighted SE and T2-weighted FSE sequences. The use of intermediate-weighted conventional SE images, T2-weighted FSE images, and a combination of both sequences were evaluated in the detection of meniscal tears. T2-weighted FSE imaging was slightly less accurate than intermediate-weighted SE imaging in the diagnosis of meniscal tears. Interpretation of the menisci using both intermediate-weighted SE and T2-weighted FSE imaging did not improve the accuracy over intermediate-weighted imaging evaluated in isolation.  相似文献   

10.
Liver metastases: detection by phase-contrast MR imaging   总被引:1,自引:0,他引:1  
Stark  DD; Wittenberg  J; Middleton  MS; Ferrucci  JT  Jr 《Radiology》1986,158(2):327-332
Forty patients with biopsy-proved metastatic liver cancers were studied by magnetic resonance (MR) imaging using one or more conventional (in-phase) pulse sequences and a corresponding phase-contrast (opposed-phase) pulse sequence. Pulse-sequence performance was quantitated by measuring signal-difference-to-noise (SD/N) ratios between cancerous tissue and liver. The SD/N performance of T2-weighted spin-echo (SE) pulse sequences improved when used with the phase-contrast technique. SE 2,000/30 opposed-phase images showed improved (P less than .001) SD/N in 72% of patients over in-phase images. The SD/N of T1-weighted SE or inversion recovery pulse sequences deteriorated when used with the phase-contrast technique. Changes in measured SD/N correlated well with image appearance and actual lesion detectability in individual cases. Phase-contrast imaging should be employed routinely when T2-weighted SE pulse sequences are relied on to detect liver cancer.  相似文献   

11.
Focal nodular hyperplasia of the liver: MR findings in 35 proved cases   总被引:6,自引:0,他引:6  
MR images of 28 patients with 35 lesions of hepatic focal nodular hyperplasia were reviewed to determine the frequency of findings considered typical of this condition (isointensity on T1- and T2-weighted pulse sequences, a central hyperintense scar on T2-weighted images, and homogeneous signal intensity). Fifteen lesions were imaged at 0.6 T with T1- and T2-weighted spin-echo (SE) pulse sequences; 20 lesions were imaged at 1.5 T with T1-weighted SE and gradient-echo pulse sequences and T2-weighted SE pulse sequences. Diagnosis of focal nodular hyperplasia was made pathologically in 25 patients, with nuclear scintigraphy in four, and with follow-up imaging in six. Only seven lesions (20%) were isointense relative to normal liver on both T1- and T2-weighted images. On T1-weighted SE images, 21 lesions (60%) were isointense relative to normal liver, 12 (34%) were hypointense, and two (6%) were hyperintense. On T2-weighted SE images, 12 lesions (34%) were isointense and 23 (66%) were hyperintense relative to normal liver. A central scar was present in 17 lesions (49%) and was hypointense relative to the lesion on T1-weighted images and hyperintense on T2-weighted images. Twenty lesions (57%) were of homogeneous signal intensity throughout the lesion, except for the presence of a central scar. All three MR imaging characteristics were present in three cases (9%). We conclude that hepatic focal nodular hyperplasia has a wide range of signal intensity on MR imaging.  相似文献   

12.
Seventy patients with clinically diagnosed athletic muscle injuries of varying severity were studied with MR imaging at 1.5 T. Twenty underwent follow-up MR studies. In all cases, SE T1-weighted and double-echo T2-weighted pulse sequences were used. These were supplemented by short T1 inversion recovery (STIR) sequence in 36 cases. Muscle injuries were more readily seen with STIR images than with SE T2-weighted images. In both initial assessment and follow-up of tears, the use of the STIR technique allowed the greatest lesion/muscle contrast. Short TR, short TE SE images provided anatomic detail and were an adjunct to T2-dependent SE images in the evaluation of organized hematomas (11 cases). Follow-up MR studies in 20 patients at variable time intervals allowed demonstration of regression of the tear in 11 cases, fibrous scar formation in 5 cases, and recurrence of the tear in 4 cases. Evolution of hematomas into scar and into cyst was demonstrated in three and two cases, respectively. Owing to the additive effect of T1 and T2 mechanisms, the STIR sequence is well suited for initial evaluation and can replace T2-weighted images in the follow-up of muscle trauma.  相似文献   

13.
BACKGROUND AND PURPOSE: Before the advent of MR imaging, intraventricular cysts were difficult to diagnose noninvasively. Among the invasive procedures used were contrast ventriculography and CT ventriculography. MR imaging, with its multiplanar imaging capabilities, excellent depiction of tissue contrast, and versatile parameters, is an important tool in the assessment of intraventricular cystic lesions. We investigated the role of three-dimensional constructive interference in steady state (3D-CISS) MR sequences in the evaluation of intraventricular cysticercal cysts. METHODS: The study group comprised 11 patients with intraventricular cysticercal cysts. MR studies included spin-echo (SE) T1-weighted, turbo-SE T2-weighted, and 3D-CISS sequences. All images were obtained on a superconducting 1.5-T MR unit. The routine and 3D-CISS sequences were reviewed and interpreted separately by two neuroradiologists. RESULTS: All patients underwent surgery for excision of intraventricular cysticercal cysts. Eight patients had cysts in the fourth ventricle, two in the lateral ventricle, and one in the third ventricle. SE T1-weighted images showed the cystic wall in nine cases, the scolex in four, and the cystic fluid in two. Turbo-SE T2-weighted images showed the cystic wall and scolex in three and four cases, respectively. The routine sequences did not show the scolex, cystic wall, or cystic fluid together in any of the 11 patients. 3D-CISS images showed the scolex in all 11 patients and the cystic wall and cystic fluid in eight patients each. In seven of the 11 patients, 3D-CISS images showed the scolex, cystic wall, and fluid together. CONCLUSION: The 3D-CISS sequence is more sensitive and specific than routine SE sequences in the diagnosis of intraventricular cysticercal cysts.  相似文献   

14.
垂体卒中的CT,MRI与临床对照研究   总被引:1,自引:0,他引:1  
分析垂体卒中CT,MRI表现与临床表明,探讨CT,MRI对垂体卒中的诊断价值。材料和方法:对手术和病理证实的46例垂体卒中进行回顾性分析。男性20例,又性26例,年龄23~69岁,平均44岁。46岁中,32例行CT检查,其中单纯平扫7例,平扫+增强25例;46例均作MRI检查,其中单纯平扫14例,平扫+增强32例。结果:46例均为垂体大腺瘤基础上并发出血和(或)坏死。32例CT检查中,垂体瘤出血1  相似文献   

15.

Introduction

To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0 Tesla (T).

Methods

We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0 T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality.

Results

At 3.0 T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts.

Conclusion

Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0 T.  相似文献   

16.
The purpose of this study was to evaluate MR imaging findings of the common extensor tendon in patients with lateral epicondylitis and asymptomatic volunteers studied on a 0.2-T dedicated system. In 23 patients (age range 29–58 years, mean age 47 years) with clinical symptoms of lateral epicondylitis MR imaging was performed using T1-, T2- and contrast-enhanced T1-weighted spin-echo sequences. In addition, the elbows of seven healthy volunteers (age range 22–29 years, mean age 25 years) and the symptom-free contralateral elbow of 11 of the 23 patients (age range 29–58 years, mean age 47 years) were studied as controls. Five patients were surgically treated after the MR examination and the results of histopathology were correlated with MR findings. Of the patients, 95.6 % showed intratendinous signal intensity changes on T1-weighted images on the symptomatic side. In 69.6 % signal alterations were observed on T2-weighted sequences and in 56.5 % an intratendinous contrast enhancement was present. Histopathology showed fibrovascular proliferation and fatty degeneration in patients with distinct signal intensity changes and contrast enhancement. Patients with only minor signal intensity changes on T1- and T2-weighted sequences and no contrast enhancement demonstrated fibrosclerotic degeneration and intratendinous cartilage formation in histopathology. The contralateral elbow showed signal intensity changes in 6 of 11 (54.5 %) cases on T1-weighted images and in 3 of 11 (27.3 %) on T2-weighted images. In the group of healthy volunteers minor signal intensity changes of the common extensor tendon could be seen in only 1 case. In patients with lateral epicondylitis of the elbow the type and extent of pathologic changes within the common extensor tendon can be evaluated using a dedicated low-field MR system. On the basis of MR imaging findings a more specified therapy planning among the variety of treatment modalities can be achieved. Received: 10 April 1998; Revision received: 13 October 1998; Accepted: 25 November 1998  相似文献   

17.
BACKGROUND AND PURPOSE: Intratumoral hemorrhage occurs frequently in pituitary macroadenoma and manifests as pituitary apoplexy and recent or old silent hemorrhage. T2*-weighted gradient-echo (GE) MR imaging is the most sensitive sequence for the detection of acute and old intracranial hemorrhage. T2*-weighted GE MR imaging was used to investigate intratumoral hemorrhage in pituitary macroadenomas. MATERIALS AND METHODS: Twenty-five consecutive patients who underwent total or subtotal resection of pituitary macroadenoma with heights from 17 to 53 mm, including 1 patient with classic pituitary apoplexy, underwent MR imaging before surgery, including T2*-weighted GE MR imaging. For histologic assessment of the hemorrhage in whole surgical specimens, we used hematoxylin-eosin staining. RESULTS: T2*-weighted GE MR imaging detected various types of dark lesions, such as "rim," "mass," "spot," and "diffuse" and combinations, indicating clinical and subclinical intratumoral hemorrhage in 12 of the 25 patients. The presence of intratumoral dark lesions on T2*-weighted GE MR imaging correlated significantly with the hemorrhagic findings on T1- and T2-weighted MR imaging (P < .02 and <.01, respectively), and the surgical and histologic hemorrhagic findings (P < .001 and <.001, respectively). CONCLUSION: T2*-weighted GE MR imaging could detect intratumoral hemorrhage in pituitary adenomas as various dark appearances. Therefore, this technique might be useful for the assessment of recent and old intratumoral hemorrhagic events in patients with pituitary macroadenomas.  相似文献   

18.
Typical ocular and CNS melanomas are hyperintense on T1-weighted MR images and hypointense on T2-weighted MR images. We performed MR imaging in 48 patients with melanoma metastatic to visceral organs. Images were reviewed retrospectively in order to determine whether there were predominant MR features specific for visceral melanoma and to see if visceral metastases have MR characteristics similar to metastases in the CNS. Eleven patients also were examined after injection of gadopentetate dimeglumine to evaluate the enhancement characteristics of these tumors. Two hundred sixty-one lesions were found. Lesions were classified according to their signal intensities relative to uninvolved liver on T1-weighted, T2-weighted, and short TI inversion recovery (STIR) pulse sequences. Most commonly, lesions were either hypointense or isointense on T1-weighted sequences and hyperintense on T2-weighted and STIR sequences (185 lesions). Less frequently, lesions were hyperintense on T1-weighted sequences and hypointense or isointense on T2-weighted and STIR sequences (59 lesions). A mixed pattern was seen on T1- and T2-weighted sequences in 17 lesions. The patterns did not correlate with lesion size. Of the three sequences studied by subjective comparison, the STIR sequence in our series had the highest sensitivity for lesion detection and yielded the highest lesion conspicuity. Injection of gadopentetate dimeglumine in 11 patients did not increase either the number or the conspicuity of lesions seen. Our results show that visceral metastases from melanoma have a wide variety of appearances on MR images. The STIR sequence appears to be optimal, and the metastases do not enhance with gadopentetate dimeglumine.  相似文献   

19.
Pancreatic adenocarcinoma: detection and staging with dynamic MR imaging   总被引:9,自引:0,他引:9  
OBJECTIVE: To compare the efficacy of dynamic contrast-enhanced MR imaging and spin-echo T1-weighted with and without fat-saturated MR imaging in the detection and staging of pancreatic adenocarcinoma. METHODS AND MATERIAL: Spin-echo T1-weighted, fat-saturated T1-weighted and dynamic breath-hold 2D-FLASH MR imaging were performed in 25 patients with pancreatic adenocarcinoma. MR images were analysed by calculating the CNR between tumor and normal portion of the pancreas. The CNRs calculated at each sequences were compared. A total of 16 out of 25 patients underwent surgery. Preoperative staging according to TNM classification was also done in patients undergoing surgery. RESULTS: The CNR was significantly different (P<0.05) in the arterial phase of dynamic MR images. The accuracy of 'T' staging was 75% for SE T1-W, fat-saturated T1-W and arterial phase of dynamic MR images. CONCLUSION: The CNRs between pancreatic carcinoma and normal pancreas is significantly higher in dynamic MR sequences than the SE T1-W, fat-saturated T1-W sequences. However, the accuracy of tumor staging according to TNM is equivocal to SE T1-W and fat-saturated T1-W images.  相似文献   

20.
The usefulness of different magnetic resonance (MR) imaging sequences (coronal and sagittal spin-echo [SE] and three-dimensional fast low-angle shot [3D FLASH]) in the detection of pituitary microadenomas before and after gadolinium injection was prospectively evaluated in 28 patients with surgical confirmation. When evaluated separately, the most useful sequences in the detection of these microadenomas were coronal pregadolinium T1-weighted SE, coronal pregadolinium 3D FLASH, coronal postgadolinium T1-weighted SE, and coronal postgadolinium 3D FLASH. The combination of pre- and postgadolinium T1-weighted sequences with pre-and postgadolinium 3D FLASH sequences produced the highest number of true-positive findings (90%) and the lowest number of false-positive findings (5%). When a 1.5-T imaging unit with a high signal-to-noise ratio allowing useful three-dimensional acquisition is used, the authors advocate a coronal T1-weighted SE sequence, followed (if necessary) by a coronal 3D FLASH sequence, both without injection of gadolinium, in the diagnosis of pituitary microadenomas. When no confident diagnosis is reached, the same sequences should be performed after the injection of gadolinium. The sagittal pre- and postgadolinium T1-weighted SE and long-TR SE sequences are useful only in specific cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号