首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 495 毫秒
1.
2.
Actuators using Shape Memory Alloy (SMA) springs could operate in different mechanical systems requiring geometric flexibility and high performance. The aim of the present study is to highlight the potential of these actuators, using their dimensional variations resulting from the phase transformations of NiTi springs (SMA) to make the movements of the system’s mobile components reversible. This reversibility is due to thermal-induced martensitic transformation of NiTi springs. The transformation promotes the extended and retracted of the springs as the phase changing (martensite–austenite) creates movement in part of the system. Therefore, the phase transition temperatures of NiTi, evaluated by differential scanning calorimetry (DSC), are required to control the dimensional variation of the spring. The influence of the number of springs in the system, as well as how impacts on the reaction time were evaluated. The different numbers of springs (two, four, and six) and the interspaces between them made it possible to control the time and the final angle attained in the mobile part of the system. Mechanical resistance, maximum angle, and the system’s reaction time using different NiTi springs highlight the role of the actuators. Fused Deposition Modelling (FDM)/Material Extrusion (MEX) or Selective Laser Sintering (SLS) was selected for shaping the composite matrix system. A new prototype was designed and developed to conduct tests that established the relationship between the recoverable deformation of the matrix suitable for the application as well as the number and distribution of the actuators.  相似文献   

3.
Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.  相似文献   

4.
Tooth enamel is inherently weak, with fracture toughness comparable with glass, yet it is remarkably resilient, surviving millions of functional contacts over a lifetime. We propose a microstructural mechanism of damage resistance, based on observations from ex situ loading of human and sea otter molars (teeth with strikingly similar structural features). Section views of the enamel implicate tufts, hypomineralized crack-like defects at the enamel–dentin junction, as primary fracture sources. We report a stabilization in the evolution of these defects, by “stress shielding” from neighbors, by inhibition of ensuing crack extension from prism interweaving (decussation), and by self-healing. These factors, coupled with the capacity of the tooth configuration to limit the generation of tensile stresses in largely compressive biting, explain how teeth may absorb considerable damage over time without catastrophic failure, an outcome with strong implications concerning the adaptation of animal species to diet.  相似文献   

5.
Polymer-clay nanocomposites are highly sought-after materials, mainly due to their applicability in a variety of avenues. From the standpoint of the preparation of these nanocomposites, however, organic compatibility with clay and adherence to “green chemistry” concepts and principles can be limiting factors. As such, the objective was to prepare a biopolymer-modified clay nanocomposite using a simple and environmentally friendly method of preparation, whereby pre-treatment of the clay for organic compatibility was bypassed. Novel montmorillonite nanocomposites were prepared using neutral guar gum and cationic guar gum. X-ray diffraction (XRD) and transmission electron microscopy (TEM) confirmed the formation of intercalated structures. A monolayer configuration of cationic guar within the interlayer space was indicated by XRD results, while treatment with neutral guar gum resulted in the observance of both monolayer and bilayer configurations. Additionally, TEM results indicated partial exfoliation. Results attributed from 13C cross polarization/magic angle spinning nuclear magnetic resonance spectroscopy (CP/MAS NMR) of the nanocomposites indicated peaks corresponding to the guar constituent, confirming the adsorption of the biopolymer. Inductively coupled plasma emission spectrometry (ICP-ES) results indicated the exchange of cations present in neutral guar gum with the sodium cations of montmorillonite, in the case of the neutral guar nanocomposites.  相似文献   

6.
Imagery of motor movement plays an important role in learning of complex motor skills, from learning to serve in tennis to perfecting a pirouette in ballet. What and where are the neural substrates that underlie motor imagery-based learning? We measured electrocorticographic cortical surface potentials in eight human subjects during overt action and kinesthetic imagery of the same movement, focusing on power in “high frequency” (76–100 Hz) and “low frequency” (8–32 Hz) ranges. We quantitatively establish that the spatial distribution of local neuronal population activity during motor imagery mimics the spatial distribution of activity during actual motor movement. By comparing responses to electrocortical stimulation with imagery-induced cortical surface activity, we demonstrate the role of primary motor areas in movement imagery. The magnitude of imagery-induced cortical activity change was ∼25% of that associated with actual movement. However, when subjects learned to use this imagery to control a computer cursor in a simple feedback task, the imagery-induced activity change was significantly augmented, even exceeding that of overt movement.  相似文献   

7.
A gradual buildup of neuronal activity known as the “readiness potential” reliably precedes voluntary self-initiated movements, in the average time locked to movement onset. This buildup is presumed to reflect the final stages of planning and preparation for movement. Here we present a different interpretation of the premovement buildup. We used a leaky stochastic accumulator to model the neural decision of “when” to move in a task where there is no specific temporal cue, but only a general imperative to produce a movement after an unspecified delay on the order of several seconds. According to our model, when the imperative to produce a movement is weak, the precise moment at which the decision threshold is crossed leading to movement is largely determined by spontaneous subthreshold fluctuations in neuronal activity. Time locking to movement onset ensures that these fluctuations appear in the average as a gradual exponential-looking increase in neuronal activity. Our model accounts for the behavioral and electroencephalography data recorded from human subjects performing the task and also makes a specific prediction that we confirmed in a second electroencephalography experiment: Fast responses to temporally unpredictable interruptions should be preceded by a slow negative-going voltage deflection beginning well before the interruption itself, even when the subject was not preparing to move at that particular moment.  相似文献   

8.
The feeling we have of our own body, sometimes called “body image,” is fundamental to self-awareness. However, by altering sensory input, the body image can be modified into impossible configurations. Can impossible movements of the body image be conjured solely via internally generated mechanisms, and, if so, do the structural characteristics of the body image modify to accommodate the new movements? We encouraged seven amputees with a vivid phantom arm to learn to perform a phantom wrist movement that defied normal anatomical constraints. Four reported success. Learning the impossible movement coincided in time with a profound change in the body image of the arm, including a sense of ownership and agency over a modified wrist joint. Remarkably, some previous movements and functional tasks involving the phantom arm became more difficult once the shift in body image had occurred. Crucially, these introspective reports were corroborated by robust empirical data from motor imagery tasks, about which amputees were naïve and to which assessors were blind. These results provide evidence that: a completely novel body image can be constructed solely by internally generated mechanisms; that the interdependence between movement repertoire and structural constraints of the body persists even when the structural constraints imparted by the body do not—the body image we construct still constrains imagined movements; and that motor learning does not necessarily need sensory feedback from the body or external feedback about task performance.  相似文献   

9.
Background: The clinical outcome of aligner therapy is closely related to the precision of its setup, which can be manually or digitally fabricated. The aim of the study is to investigate the suitability of manual setups made for aligner therapy in terms of the precision of tooth movements. Methods: Six dental technicians were instructed to adjust each of eleven duplicate plaster casts of a patient models as follows: a 1 mm pure vestibular translation of tooth 11 and a 15° pure mesial rotation of tooth 23. The processed setup models were 3D scanned and matched with the reference model. The one-sample Wilcoxon signed-rank test (p < 0.05) was used for evaluation. Results: The overall precision of the translational movement covers a wide range of values from 0.25 to 2.26 mm (median: 1.09 mm). The target value for the rotation of tooth 23 was achieved with a median rotation of 9.76° in the apical-occlusal direction. Unwanted movements in the other planes also accompanied the rotation. Conclusions: A manual setup can only be fabricated with limited precision. Besides the very high variability between technicians, additional unwanted movements in other spatial planes occurred. Manually fabricated setups should not be favored for aligner therapy due to limited precision.  相似文献   

10.
Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth’s center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth’s center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth’s center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.  相似文献   

11.
Restoration of primary teeth is among the main clinical applications of glass-ionomer cements (GIC). The aim of the study was to review and summarize existing evidence of in vitro bond strength of glass-ionomer (GI) restoratives to enamel and dentin of primary teeth. A literature search was performed in PubMed/Medline, Scopus, Web of Science, Cochrane, and Google Scholar databases to identify studies published until April 2021. The search strategy was: (“glass”) and (“ionomer”) and (“primary” or “deciduous”) and (“bond” or “tensile” or “shear”). Two researchers independently retrieved articles that reported on the bond strength of GIC to primary dentin and/or enamel. The meta-analysis was performed to compare the bond strength values of conventional (C) GIC and resin-modified (RM) GIC to different substrates. From 831 potentially eligible articles, 30 were selected for the full-text examination, and 7 were included in the analysis. Studies were rated at high (3), medium (3), and low (1) risk of bias. RM-GIC showed higher bond strength to primary enamel and dentin compared to the C-GIC. Meta-analysis of in vitro studies, evaluating bonding properties of GI restoratives to primary teeth, suggests the superior performance of RM-GIC. However, there is a lack of studies that examine the properties of novel GI formulations.  相似文献   

12.
The following article describes influence of pressure welded or bound chips to the gear tooth flank and/or the tooth root on a carburized case and surface layer hardness of Pyrowear 53 steel gears, machined by Power Skiving method. This paper is focused only on one factor, the chips generated while forming gear teeth by power skiving, which could result in local changes in the carburized case parameters as a negatively affecting point of mechanical performance of the carburized case. The chips, due to the specifics of the power skiving process and the kinematics of tooth forming, could be subject to the phenomena of pressure welding or binding of chips to the tooth. During the carburizing stage of the downstream manufacturing processes, the chips form a diffusion barrier, which ultimately could result in localized changes in the carburized case. This work was an attempt to answer the question of how and to what extent the chips affect the case hardening. Performed simulations of chips by a generating cupper “spots”, mentioned in the study, represent a new approach in connection with minimization of errors, which could appear during carbon case depth and case hardness analysis for typical chips, generated during the machining process—assurance that a complete chip was bound to the surface. Hardness correlation for zones, where the chip appears with areas free of chips, gives simple techniques for assessment. Performed tests increased the knowledge about the critical size of the chip—1.5 mm, which could affect the case hardening. Obtained experimental test results showed that the appearance of chip phenomena on the gear tooth might have a negative impact on a carburized case depth and hardened layer.  相似文献   

13.
Changes in tooth shape have played a major role in vertebrate evolution with modification of dentition allowing an organism to adapt to new feeding strategies. The current view is that molar teeth evolved from simple conical teeth, similar to canines, by progressive addition of extra “cones” to form progressively complex multicuspid crowns. Mammalian incisors, however, are neither conical nor multicuspid, and their evolution is unclear. We show that hypomorphic mutation of a cell surface receptor, Lrp4, which modulates multiple signaling pathways, produces incisors with grooved enamel surfaces that exhibit the same molecular characteristics as the tips of molar cusps. Mice with a null mutation of Lrp4 develop extra cusps on molars and have incisors that exhibit clear molar-like cusp and root morphologies. Molecular analysis identifies misregulation of Shh and Bmp signaling in the mutant incisors and suggests an uncoupling of the processes of tooth shape determination and morphogenesis. Incisors thus possess a developmentally suppressed, cuspid crown-like morphogenesis program similar to that in molars that is revealed by loss of Lrp4 activity. Several mammalian species naturally possess multicuspid incisors, suggesting that mammals have the capacity to form multicuspid teeth regardless of location in the oral jaw. Localized loss of enamel may thus have been an intermediary step in the evolution of cusps, both of which use Lrp4-mediated signaling.  相似文献   

14.
To date, the effect of tooth loss on all-cause mortality among elderly patients with a different weight group has not been assessed. This retrospective cohort study evaluated the data obtained from a government-sponsored, annual physical examination program for elderly citizens residing in Taipei City during 2005 to 2007, and follow-up to December 31, 2010. We recruited 55,651 eligible citizens of Taipei City aged ≥65 years, including 29,572 men and 26,079 women, in our study. Their mortality data were ascertained based on the national death files. The number of missing teeth was used as a representative of oral health status. We used multivariate Cox proportional hazards regression analysis to determine the association between tooth loss and all-cause mortality. After adjustment for all confounders, the hazard ratios (HRs) of all-cause mortality in participants with no teeth, 1 to 9 teeth, and 10 to 19 teeth were 1.36 [95% confidence interval (CI): 1.15–1.61], 1.24 (95% CI: 1.08–1.42), and 1.19 (95% CI: 1.09–1.31), respectively, compared with participants with 20 or more teeth. A significant positive correlation of body mass index (BMI) with all-cause mortality was found in underweight and overweight elderly patients and was represented as a U-shaped curve. Subgroup analysis revealed a significant positive correlation in underweight (no teeth: HR = 1.49, 95% CI: 1.21–1.83; 1–9 teeth: HR = 1.23, 95% CI: 1.03–1.47; 10–19 teeth: HR = 1.20, 95% CI: 1.06–1.36) and overweight participants (no teeth: HR = 1.37, 95% CI: 1.05–1.79; 1–9 teeth: HR = 1.27, 95% CI: 1.07–1.52). The number of teeth lost is associated with an increased risk of all-cause mortality, particularly for participants with underweight and overweight.  相似文献   

15.
The purpose of this study was to investigate the effect of retainer material and retainer position on a tooth to resist movement of the tooth in a simulation model. Bidirectional continuous glass fiber-reinforced composite (FRC) retainers and control retainers of steel wires were tested. The FRC retainers had a polymer matrix of bisphenol-A-glycidyldimethacrylate (bis-GMA) and poly(methylmethacrylate) (PMMA), and it was cured with a photoinitiator system. The retainers were adhered to a lower jaw Frasaco model in two different positions. Resistance against the movement of one tooth was measured from two directions. The average load values within the FRC retainer groups were higher than within the metal retainer groups. The load values for the groups loaded from the axial direction were higher than those loaded from the buccal direction. FRC retainers, which were located 1–2 mm from the incisal edge, showed higher load values than those located 4–5 mm from the incisal edge. There was a significant difference in load values between FRC retainers and metal retainers (p < 0.01). The wire position and the direction of force also had significant effects (p < 0.01). There were no significant differences between metal retainer groups. The results of this study suggest that metal retainers are more flexible, allowing for tooth movements of larger magnitude than with FRC retainers.  相似文献   

16.
In the European standards specifying disc spring manufacturing, geometry, shape and characteristic, an edge rounding is prescribed. Common methods for the calculation of disc spring characteristics, even in these standards, are based on a rectangular cross-section. This discrepancy can lead to a considerable divergence of the computed characteristic from the characteristic determined by testing. In literature, this divergence has not yet been examined with regard to rounded edges. In this paper, a new method addressing this problem is introduced. For this purpose, the geometry of idealized disc springs is parameterized. Based on four edge radii and two angles of the inner and outer faces, equations to compute the initial cone angle and the lever arm are introduced. These equations are used to formulate an algorithm to adapt other computation methods to non-rectangular cross-sections and rounded edges. The method is applied to the formulas by AlmenLaszlo, CurtiOrlando, Zheng and those by Kobelev. FE simulations of disc springs with rounded edges and a non-rectangular cross-section were used to verify the new formulas. The results show that the introduced method can be applied to known characteristic computation methods and result in a model expansion taking cross-section variations into account. The adjusted characteristics show more accurate alignment to the FE simulation for the cross-section variations investigated. These findings not only close the geometric gap between the manufacturing guidelines and the computation on an analytical basis, they also define a new parameter space for designs of disc springs and a corresponding force computation method to optimize spring characteristics.  相似文献   

17.
Arrestin-1 (visual arrestin) binds to light-activated phosphorylated rhodopsin (P-Rh*) to terminate G-protein signaling. To map conformational changes upon binding to the receptor, pairs of spin labels were introduced in arrestin-1 and double electron–electron resonance was used to monitor interspin distance changes upon P-Rh* binding. The results indicate that the relative position of the N and C domains remains largely unchanged, contrary to expectations of a “clam-shell” model. A loop implicated in P-Rh* binding that connects β-strands V and VI (the “finger loop,” residues 67–79) moves toward the expected location of P-Rh* in the complex, but does not assume a fully extended conformation. A striking and unexpected movement of a loop containing residue 139 away from the adjacent finger loop is observed, which appears to facilitate P-Rh* binding. This change is accompanied by smaller movements of distal loops containing residues 157 and 344 at the tips of the N and C domains, which correspond to “plastic” regions of arrestin-1 that have distinct conformations in monomers of the crystal tetramer. Remarkably, the loops containing residues 139, 157, and 344 appear to have high flexibility in both free arrestin-1 and the P-Rh*complex.  相似文献   

18.
Production of the folding-active state of a GroEL ring involves initial cooperative binding of ATP, recruiting GroES, followed by large rigid body movements that are associated with ejection of bound substrate protein into the encapsulated hydrophilic chamber where folding commences. Here, we have addressed how many of the 7 subunits of a GroEL ring are required to bind ATP to drive these events, by using mixed rings with different numbers of wild-type and variant subunits, the latter bearing a substitution in the nucleotide pocket that allows specific block of ATP binding and turnover by a pyrazolol pyrimidine inhibitor. We observed that at least 2 wild-type subunits were required to bind GroES. By contrast, the triggering of polypeptide release and folding required a minimum of 4 wild-type subunits, with the greatest extent of refolding observed when all 7 subunits were wild type. This is consistent with the requirement for a “power stroke” of forceful apical movement to eject polypeptide into the chamber.  相似文献   

19.
The stable isotope compositions of biologically precipitated apatite in bone, teeth, and scales are widely used to obtain information on the diet, behavior, and physiology of extinct organisms and to reconstruct past climate. Here we report the application of a new type of geochemical measurement to bioapatite, a “clumped-isotope” paleothermometer, based on the thermodynamically driven preference for 13C and 18O to bond with each other within carbonate ions in the bioapatite crystal lattice. This effect is dependent on temperature but, unlike conventional stable isotope paleothermometers, is independent from the isotopic composition of water from which the mineral formed. We show that the abundance of 13C-18O bonds in the carbonate component of tooth bioapatite from modern specimens decreases with increasing body temperature of the animal, following a relationship between isotope “clumping” and temperature that is statistically indistinguishable from inorganic calcite. This result is in agreement with a theoretical model of isotopic ordering in carbonate ion groups in apatite and calcite. This thermometer constrains body temperatures of bioapatite-producing organisms with an accuracy of 1–2 °C. Analyses of fossilized tooth enamel of both Pleistocene and Miocene age yielded temperatures within error of those derived from similar modern taxa. Clumped-isotope analysis of bioapatite represents a new approach in the study of the thermophysiology of extinct species, allowing the first direct measurement of their body temperatures. It will also open new avenues in the study of paleoclimate, as the measurement of clumped isotopes in phosphorites and fossils has the potential to reconstruct environmental temperatures.  相似文献   

20.
This paper discusses the issues of strength and creep of polymeric materials used in orthodontic appliances. Orthodontic biomechanics is focused on the movement of individual teeth or dental groups as a result of the force applied by orthodontic appliances. Stresses in the construction of functional and biomechanical appliances is generated when using the apparatus in the oral cavity. The orthodontic appliance must maintain its shape and not be damaged during treatment so strength and creep resistance are fundamental properties. It was assumed that the clinical success of orthodontic appliances can be determined by these performance properties. The aim of the work was the experimental assessment of comparative bending strength and creep resistance of selected popular polymer materials used in the production of biomechanical orthodontic appliances. Four commercial materials manufactured by the world class producers were tested: NextDent Ortho Rigid (Vertex-Dental B.V., Soesterberg, The Netherlands) marked as “1A”; Erkocryl (ERKODENT Erich Kopp GmbH, Pfalzgrafenweiler, Germany)-“2A”; Vertex Orthoplast (Vertex Dental B.V.), blue, marked as “3A” and material with the same name as “3A” but orange, marked in the article as “4A”. All the tests were carried out after aging in artificial saliva for 48 h at a temperature of 37 °C. Flexular strength and flexular modulus were made using the three point bending method according to the ISO 178 technical standard. Creep tests were carried out according to the method contained in ISO 899-2. The creep test was carried out in an artificial saliva bath at 37 °C. The creep tests showed significant differences in the strength, modulus and deformability of the tested materials. The strength reliability of the tested materials also varied. The research shows that the 2A material can be used for orthodontic applications in which long-term stresses should be lower than 20 MPa.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号