首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A silicon photomultiplier (Si-PM) is a promising photodetector for PET, especially for PET/MRI combined systems, due to its high gain, small size, and lower sensitivity to static magnetic fields. However, these properties are also promising for gamma camera systems for single-photon imaging. We developed an ultra-high-resolution Si-PM-based compact gamma camera system for small animals. Y(2)SiO(5):Ce (YSO) was selected as scintillators because of its high light output and no natural radioactivity. The gamma camera consists of 0.6 mm × 0.6 mm × 6 mm YSO pixels combined with a 0.1 mm thick reflector to form a 17 × 17 matrix that was optically coupled to a Si-PM array (Hamamatsu multi-pixel photon counter S11064-050P) with a 2 mm thick light guide. The YSO block size was 12 mm × 12 mm. The YSO gamma camera was encased in a 5 mm thick gamma shield, and a parallel hole collimator was mounted in front of the camera (0.5 mm hole, 0.7 mm separation, 5 mm thick). The two-dimensional distribution for the Co-57 gamma photons (122 keV) was almost resolved. The energy resolution was 24.4% full-width at half-maximum (FWHM) for the Co-57 gamma photons. The spatial resolution at 1.5 mm from the collimator surface was 1.25 mm FWHM measured using a 1 mm diameter Co-57 point source. Phantom and small animal images were successfully obtained. We conclude that a Si-PM-based gamma camera is promising for molecular imaging research.  相似文献   

2.
We have developed a small scintillation camera dedicated to breast imaging and have evaluated the performance of the system. In order to increase the limited field of view (FOV) determined by the size of a position-sensitive photomultiplier tube (PSPMT), the imaging characteristics of a diverging hole collimator (DHC) were also investigated. The small scintillation camera system consists of an NaI(Tl) crystal (60 mm x 60 mm x 6 mm) coupled to a Hamamatsu R3941 PSPMT, a resistor chain circuit, preamplifiers, nuclear instrument modules, an analogue to digital converter and a PC for control and display. The intrinsic energy resolution of the system was 12.9% FWHM at 140 keV. The spatial resolution was measured using a line-slit mask and 99mTc point sources and was 3.1 mm FWHM. The intrinsic sensitivity of the system was approximately 162 counts/s kBq(-1). The DHC made it possible to image a larger FOV (75 x 75 mm2 at the surface of collimator) than a parallel-hole collimator (60 x 60 mm2). The system sensitivity obtained using the DHC gradually decreased with distance (3% at 1 cm, 6% at 2 cm and 9% at 3 cm). The results demonstrate that the system developed in this study could be utilized clinically to image malignant breast tumours. A DHC can be employed to expand the FOV of the system confined by the size of PSPMT with a modest compromise in the performance of the system.  相似文献   

3.
The physical performance of a prototype slat collimator is described for gamma camera planar imaging at 511 keV. Measurements were made of sensitivity, spatial resolution and a septal penetration index at 511 keV. These measurements were repeated with a commercial parallel hole collimator designed for 511 keV imaging. The slat collimator sensitivity was 22.9 times that of the parallel hole collimator with 10 cm tissue equivalent scatter material, and 16.8 times the parallel hole collimator sensitivity in air. Spatial resolution was also better for the slat collimator than the parallel hole collimator (FWHM at 10 cm in air 17.9 mm and 21.2 mm respectively). Septal penetration was compared by a single value for the counts at 120 mm from the point source profile peak, expressed as a percentage of the peak counts, showing less penetration for the slat collimator than the parallel hole collimator (1.9% versus 3.6% respectively). In conclusion, these results show that the slat collimator may have advantages over the parallel hole collimator for 511 keV imaging, though the greater complexity of operation of the slat collimator and potential sources of artefact in slat collimator imaging are recognized.  相似文献   

4.
The purpose of the study was to evaluate the resolution recovery in the list-mode iterative reconstruction algorithm (LMIRA) for SPECT. In this study we compare the performance of the proposed method with other iterative resolution recovery methods for different noise levels. We developed an iterative reconstruction method which uses list-mode data instead of binned data. The new algorithm makes use of a more accurate model of the collimator structure. We compared the SPECT list-mode reconstruction with MLEM, OSEM and RBI, all including resolution recovery. For the evaluation we used Gaussian shaped sources with different FWHM at three different locations and three noise levels. For these distributions we calculated the reconstructed images for a different number of iterations. The absolute error for the reconstructed images was used to evaluate the performance. The performance of all four methods is comparable for the sources located in the centre of the field of view. For the sources located out of the centre, the error of the list-mode method is significantly lower than that of the other methods. Splitting the system model into a separate object-dependent and detector-dependent module gives us a flexible reconstruction method. With this we can very easily adapt the resolution recovery to different collimator types.  相似文献   

5.
In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimator in terms of spatial resolution in the reconstructed images. The main application of this system is small animal SPECT imaging.  相似文献   

6.
目的:探讨多排螺旋CT(MSCT)轴向分辨力或断层灵敏度曲线(SSP)和图像噪声的影响因素。方法:使用临床常 用的腹部扫描模式,采用不同直径的模板,重建层厚、螺距、电压(kV)、重建算法等扫面参数,进行MSCT扫描,对不同参数 对断层图像SSP和图像噪声的影响进行统计学分析。结果:当螺距和准直器宽度保持不变,不同层厚和重建算法得到的 SSP的半高宽FWHM值基本保持不变(P>0.05);当重建算法和准直器宽度保持不变,不同螺距和层厚得到的SSP的半高 宽FWHM值基本保持不变(P>0.05);不同准直器宽度,同螺距和层厚得到的SSP 的半高宽FWHM值基本保持不变(P> 0.05);随着层厚、mAs增加,图像噪声减小(P<0.05);随着kV增加,图像噪声随之减小,不同重建算法下图像噪声存在明显 差异(P<0.05)。结论:卷积重建算法、螺距和准直器宽度对SSP的影响很小,螺距对图像噪声影响很小,而层厚、重建算 法、mAs、kV对图像噪声影响大。层厚、mAs、kV增大,图像噪声减小;重建算法分辨率越高,图像噪声越大。  相似文献   

7.
The main remaining challenge for a gamma camera is to overcome the existing trade-off between collimator spatial resolution and system sensitivity. This problem, strongly limiting the performance of parallel hole collimated gamma cameras, can be overcome by applying new collimator designs such as rotating slat (RS) collimators which have a much higher photon collection efficiency. The drawback of a RS collimated gamma camera is that, even for obtaining planar images, image reconstruction is needed, resulting in noise accumulation. However, nowadays iterative reconstruction techniques with accurate system modeling can provide better image quality. Because the impact of this modeling on image quality differs from one system to another, an objective assessment of the image quality obtained with a RS collimator is needed in comparison to classical projection images obtained using a parallel hole (PH) collimator. In this paper, a comparative study of image quality, achieved with system modeling, is presented. RS data are reconstructed to planar images using maximum likelihood expectation maximization (MLEM) with an accurate Monte Carlo derived system matrix while PH projections are deconvolved using a Monte Carlo derived point-spread function. Contrast-to-noise characteristics are used to show image quality for cold and hot spots of varying size. Influence of the object size and contrast is investigated using the optimal contrast-to-noise ratio (CNR(o)). For a typical phantom setup, results show that cold spot imaging is slightly better for a PH collimator. For hot spot imaging, the CNR(o) of the RS images is found to increase with increasing lesion diameter and lesion contrast while it decreases when background dimensions become larger. Only for very large background dimensions in combination with low contrast lesions, the use of a PH collimator could be beneficial for hot spot imaging. In all other cases, the RS collimator scores better. Finally, the simulation of a planar bone scan on a RS collimator revealed a hot spot contrast improvement up to 54% compared to a classical PH bone scan.  相似文献   

8.
9.
The PETRRA positron camera is a large-area (600 mm x 400 mm sensitive area) prototype system that has been developed through a collaboration between the Rutherford Appleton Laboratory and the Institute of Cancer Research/Royal Marsden Hospital. The camera uses novel technology involving the coupling of 10 mm thick barium fluoride scintillating crystals to multi-wire proportional chambers filled with a photosensitive gas. The performance of the camera is reported here and shows that the present system has a 3D spatial resolution of approximately 7.5 mm full-width-half-maximum (FWHM), a timing resolution of approximately 3.5 ns (FWHM), a total coincidence count-rate performance of at least 80-90 kcps and a randoms-corrected sensitivity of approximately 8-10 kcps kBq(-1) ml. For an average concentration of 3 kBq ml(-1) as expected in a patient it is shown that, for the present prototype, approximately 20% of the data would be true events. The count-rate performance is presently limited by the obsolete off-camera read-out electronics and computer system and the sensitivity by the use of thin (10 mm thick) crystals. The prototype camera has limited scatter rejection and no intrinsic shielding and is, therefore, susceptible to high levels of scatter and out-of-field activity when imaging patients. All these factors are being addressed to improve the performance of the camera. The large axial field-of-view of 400 mm makes the camera ideally suited to whole-body PET imaging. We present examples of preliminary clinical images taken with the prototype camera. Overall, the results show the potential for this alternative technology justifying further development.  相似文献   

10.
A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with functional information from SPECT images. The patient-specific attenuation map derived from the x-ray CT images can be used to perform attenuation correction of the SPECT images, so that accurate quantitative information can be obtained. The fan-beam scanning geometry and the use of a segmented HPGe detector array impose special constraints on the design of the collimator for the system. Based on a signal detection model, an efficiency-resolution figure of merit (ERFM) as a function of the collimator geometric efficiency, system resolution width, and object diameter is defined. The ERFM is proportional to the square of the detection signal-to-noise ratio. The collimator design parameters can then be optimized by optimizing the ERFM for an anticipated object diameter. The collimator point-spread function, geometric efficiency, and resolution are calculated. The collimator optimized for the detection of a 1-cm object will have a single-slice point source efficiency of 1.2 X 10(-4), and a FWHM of 6.5 mm at the center of the reconstruction circle, at 12 cm from the collimator face. The minimum object contrast which will give a detection SNR of 5 is 74%, for a total accumulated count per slice of 2 X 10(6).  相似文献   

11.
The BEAM code is used to simulate nine photon beams from three major manufacturers of medical linear accelerators (Varian, Elekta, and Siemens), to derive and evaluate estimates for the parameters of the electron beam incident on the target, and to study the effects of some mechanical parameters like target width, primary collimator opening, flattening filter material and density. The mean energy and the FWHM of the incident electron beam intensity distributions (assumed Gaussian and cylindrically symmetric) are derived by matching calculated percentage depth-dose curves past the depth of maximum dose (within 1% of maximum dose) and off-axis factors (within 2sigma at 1% statistics or less) with measured data from the AAPM RTC TG-46 compilation. The off-axis factors are found to be very sensitive to the mean energy of the electron beam, the FWHM of its intensity distribution, its angle of incidence, the dimensions of the upper opening of the primary collimator, the material of the flattening filter and its density. The off-axis factors are relatively insensitive to the FWHM of the electron beam energy distribution, its divergence and the lateral dimensions of the target. The depth-dose curves are sensitive to the electron beam energy, and to its energy distribution, but they show no sensitivity to the FWHM of the electron beam intensity distribution. The electron beam incident energy can be estimated within 0.2 MeV when matching either the measured off-axis factors or the central-axis depth-dose curves when the calculated uncertainties are about 0.7% at the 1 sigma level. The derived FWHM (+/-0.1 mm) of the electron beam intensity distributions all fall within 1 mm of the manufacturer specifications except in one case where the difference is 1.2 mm.  相似文献   

12.
Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT   总被引:9,自引:0,他引:9  
The objective of this investigation was to evaluate small-field-of-view, ultra-high-resolution pinhole collimation for a rotating-camera SPECT system that could be used to image small laboratory animals. Pinhole collimation offers distinct advantages over conventional parallel-hole collimation when used to image small objects. Since geometric sensitivity increases markedly for points close to the pinhole, small-diameter and high-magnification pinhole geometries may be useful for selected imaging tasks when used with large-field-of-view scintillation cameras. The use of large magnifications can minimize the loss of system resolution caused by the intrinsic resolution of the scintillation camera. A pinhole collimator has been designed and built that can be mounted on one of the scintillation cameras of a triple-head SPECT system. Three pinhole inserts with approximate aperture diameters of 0.6, 1.2 and 2.0 mm have been built and can be mounted individually on the collimator housing. When a ramp filter is used with a three-dimensional (3D) filtered backprojection (FBP) algorithm, the three apertures have in-plane SPECT spatial resolutions (FWHM) at 4 cm of 1.5, 1.9 and 2.8 mm, respectively. In-air point source sensitivities at 4 cm from the apertures are 0.9, 2.6 and 5.7 counts s(-1) microCi(-1) (24, 70 and 154 counts s(-1) MBq(-1)) for the 0.6, 1.2 and 2.0 mm apertures, respectively. In vitro image quality was evaluated with a micro-cold-rod phantom and a micro-Defrise phantom using both the 3D FBP algorithm and a 3D maximum likelihood-expectation maximization (ML-EM) algorithm. In vivo image quality was evaluated using two (315 and 325 g) rats. Ultra-high-resolution pinhole SPECT is an inexpensive and simple approach for imaging small animals that can be used with existing rotating-camera SPECT system.  相似文献   

13.
Based on the structure of the original helical FDK algorithm, a three-dimensional (3D)-weighted cone beam filtered backprojection (CB-FBP) algorithm is proposed for image reconstruction in volumetric CT under helical source trajectory. In addition to its dependence on view and fan angles, the 3D weighting utilizes the cone angle dependency of a ray to improve reconstruction accuracy. The 3D weighting is ray-dependent and the underlying mechanism is to give a favourable weight to the ray with the smaller cone angle out of a pair of conjugate rays but an unfavourable weight to the ray with the larger cone angle out of the conjugate ray pair. The proposed 3D-weighted helical CB-FBP reconstruction algorithm is implemented in the cone-parallel geometry that can improve noise uniformity and image generation speed significantly. Under the cone-parallel geometry, the filtering is naturally carried out along the tangential direction of the helical source trajectory. By exploring the 3D weighting's dependence on cone angle, the proposed helical 3D-weighted CB-FBP reconstruction algorithm can provide significantly improved reconstruction accuracy at moderate cone angle and high helical pitches. The 3D-weighted CB-FBP algorithm is experimentally evaluated by computer-simulated phantoms and phantoms scanned by a diagnostic volumetric CT system with a detector dimension of 64 x 0.625 mm over various helical pitches. The computer simulation study shows that the 3D weighting enables the proposed algorithm to reach reconstruction accuracy comparable to that of exact CB reconstruction algorithms, such as the Katsevich algorithm, under a moderate cone angle (4 degrees) and various helical pitches. Meanwhile, the experimental evaluation using the phantoms scanned by a volumetric CT system shows that the spatial resolution along the z-direction and noise characteristics of the proposed 3D-weighted helical CB-FBP reconstruction algorithm are maintained very well in comparison to the FDK-type algorithms. Moreover, the experimental evaluation by clinical data verifies that the proposed 3D-weighted CB-FBP algorithm for image reconstruction in volumetric CT under helical source trajectory meets the challenges posed by diagnostic applications of volumetric CT imaging.  相似文献   

14.
Lief EP  Lutz WR 《Medical physics》2000,27(10):2372-2375
Two independent methods have been utilized for determination of effective source sizes for 6, 12, and 20 MeV electron beams generated by a Varian 2100C linear accelerator. First, a multislit camera has been constructed using parallel aluminum plates and plastic strip spacers, similar to the beam-spot camera for the photon source imaging. Second, pinhole imaging was performed using a lead plate with a small hole on the central axis of the beam. The plate thickness and the hole diameter varied with electron energy. The cameras were positioned directly at the opening of the movable photon collimator. The size of the source distribution from each camera was characterized by its full width at half-maximum (FWHM) value. The measured values of FWHM are different for each camera because of their different imaging principles. For the multislit camera, the measured FWHM values were (6.3 +/- 0.4) cm for the 6 MeV beam, (3.6 +/- 0.4) cm for 12 MeV, and (2.7 +/- 0.4) cm for 20 MeV. For the pinhole camera the measured values of FWHM were (7.9 +/- 0.6) cm for 6 MeV, (4.5 +/- 0.4) cm for 12 MeV, and (3.0 +/- 0.4) cm for the 20 MeV beam. Additionally, the effective source position was derived from output measurements at different values of the SSD, which were fitted to the inverse square law.  相似文献   

15.
An improved method for an easy, rapid measurement of the intrinsic spatial resolution of a gamma camera is presented. A simplified model was previously developed based solely on mean and standard deviation measurements taken from a region of interest in bar pattern images. This led to an estimate of the modulation transfer function and the full width at half maximum (FWHM) of a line spread function (LSF). The improved method involved expanding the simplified model to incorporate input modulation, square wave input versus the assumed sinusoidal input, aperture (pixel) size, and scatter from the plastic in the bar pattern. The input square wave modulation was calculated to be unity for the typical bar patterns used for gamma camera quality control assessment. For the typical range of bar sizes available, in combination with the typical resolving capabilities of gamma cameras, the sinusoidal approximation of the bar pattern was found to be valid (<1% contribution to the measured resolution from higher harmonic frequencies present in a square wave input with an effective input modulation greater than unity by a factor of 4/pi). The aperture correction factor was calculated for numerous bar and pixel size combinations. Applying the aperture correction factor results in an improvement in the accuracy of the calculated FWHM values, especially for large apertures (pixel sizes). For a camera with a specified FWHM value of 3.5 mm, the simplified model predicts values ranging from 3.2 to 4.1 mm, when the acquisition matrix varies from 128(2) to 512(2). When the expanded model is used with the aperture correction applied, this range was reduced to 3.6-3.9 mm. The scatter correction further improved the calculated FWHM (from 3.6 to 3.8 mm). It is suggested that the expanded model should be used when more accurate measurements are desired, such as in acceptance testing.  相似文献   

16.
目的:改进平行孔准直器SPECT系统的成像方法,快速、精确地实现有序子集期望值最大化(OSEM)重建算法。方法:采用理想平行孔和张角效应平行孔准直器两种模型,将准直器的空间响应融入系统传输矩阵,利用改进的射线跟踪算法进行衰减校正。结果:随着准直器张角的增加,Jaszczak模型的重建图像在边界出现明显的亮环;利用考虑准直器空间响应的系统矩阵进行图像重建.能较好的抑制边界伪影。结论:融入准直器空间响应函数的系统矩阵更为精确、贴近真实情况,能较好的抑制边界伪影,提高了重建图像的对比度和信噪比。  相似文献   

17.
Obtaining the best possible task performance using reconstructed SPECT images requires optimization of both the collimator and reconstruction parameters. The goal of this study is to determine how to perform this optimization, namely whether the collimator parameters can be optimized solely from projection data, or whether reconstruction parameters should also be considered. In order to answer this question, and to determine the optimal collimation, a digital phantom representing a human torso with 16 mm diameter hot lesions (activity ratio 8:1) was generated and used to simulate clinical SPECT studies with parallel-hole collimation. Two approaches to optimizing the SPECT system were then compared in a lesion quantification task: sequential optimization, where collimation was optimized on projection data using the Cramer–Rao bound, and joint optimization, which simultaneously optimized collimator and reconstruction parameters. For every condition, quantification performance in reconstructed images was evaluated using the root-mean-squared-error of 400 estimates of lesion activity. Compared to the joint-optimization approach, the sequential-optimization approach favoured a poorer resolution collimator, which, under some conditions, resulted in sub-optimal estimation performance. This implies that inclusion of the reconstruction parameters in the optimization procedure is important in obtaining the best possible task performance; in this study, this was achieved with a collimator resolution similar to that of a general-purpose (LEGP) collimator. This collimator was found to outperform the more commonly used high-resolution (LEHR) collimator, in agreement with other task-based studies, using both quantification and detection tasks.  相似文献   

18.
System characteristics of SPECT with a slat collimated strip detector   总被引:1,自引:0,他引:1  
In classical SPECT with parallel hole collimation, the sensitivity is constant over the field of view (FOV). This is no longer the case if a rotating slat collimator with planar photon collection is used: there will be a significant variation of the sensitivity within the FOV. Since not compensating for this inhomogeneous sensitivity distribution would result in non-quantitative images, an accurate knowledge of the sensitivity is mandatory to account for it during reconstruction. On the other hand, the spatial resolution versus distance dependency remains unaltered compared to parallel hole collimation. For deriving the sensitivity, different factors have to be taken into account: a first factor concerns the intrinsic detector properties and will be incorporated into the calculations as a detection efficiency term depending on the incident angle. The calculations are based on a second and more pronounced factor: the collimator and detector geometry. Several assumptions will be made for the calculation of the sensitivity formulae and it will be proven that these calculations deliver a valid prediction of the sensitivity at points far enough from the collimator. To derive a close field model which also accounts for points close to the collimator surface, a modified calculation method is used. After calculating the sensitivity in one plane it is easy to obtain the tomographic sensitivity. This is done by rotating the sensitivity maps for spin and camera rotation. The results derived from the calculations are then compared to simulation results and both show good agreement after including the aforementioned detection efficiency term. The validity of the calculations is also proven by measuring the sensitivity in the FOV of a prototype rotating slat gamma camera. An expression for the resolution of these planar collimation systems is obtained. It is shown that for equal collimator dimensions the same resolution-distance relationship is obtained as for parallel hole collimators. Although, a better spatial resolution can be obtained with our prototype camera due to the smaller pitch of the slats. This can be achieved without a major drop in system sensitivity due to the fact that the slats consist of less collimator material compared to a parallel hole collimator. The accuracy of the calculated resolution is proven by comparison with Monte Carlo simulation and measurement resolution values.  相似文献   

19.
A multi-pinhole collimation device is developed that uses the gamma camera detectors of a clinical SPECT or SPECT-CT scanner to produce high-resolution SPECT images. The device consists of a rotating cylindrical collimator having 22 tungsten pinholes with 0.9 mm diameter apertures and an animal bed inside the collimator that moves linearly to provide helical or ordered-subsets axial sampling. CT images also may be acquired on a SPECT-CT scanner for purposes of image co-registration and SPECT attenuation correction. The device is placed on the patient table of the scanner without attaching to the detectors or scanner gantry. The system geometry is calibrated in-place from point source data and is then used during image reconstruction. The SPECT imaging performance of the device is evaluated with test phantom scans. Spatial resolution from reconstructed point source images is measured to be 0.6 mm full width at half maximum or better. Micro-Derenzo phantom images demonstrate the ability to resolve 0.7 mm diameter rod patterns. The axial slabs of a Micro-Defrise phantom are visualized well. Collimator efficiency exceeds 0.05% at the center of the field of view, and images of a uniform phantom show acceptable uniformity and minimal artifact. The overall simplicity and relatively good imaging performance of the device make it an interesting low-cost alternative to dedicated small animal scanners.  相似文献   

20.
In this article we compare the accuracy of a diode laser densitometer emitting 675.2 nm to that of a commercial He-Ne laser densitometer emitting 632.8 nm for GafChromic MD-55 film readout. A Leksell gamma unit (AB Elekta Stockholm, Sweden) Model B with a 14 and 8 mm collimator at the same isocenter (combined 11 mm collimator) was used to irradiate GafChromic MD-55 films. Dose response curves, dose cross profile and FWHM were measured with a custom-designed diode laser scanning device, emitting light at 675.2 nm. The same data were recorded with a commercial He-Ne laser densitometer (PTW FIPS Plus, Freiburg, Germany), emitting light at 632.8 nm. Both measurements were compared to dose cross profiles of a radiosurgery dose planning program (GammaPlan 5.12, Elekta, Sweden). Compared to the commercial He-Ne laser densitometer, the custom-designed diode laser scanning device showed better agreement with the calculated dose cross profile. For two axes, the full width half maxima (FWHM) of the diode laser scanning device was within 0.1 mm deviation compared to the data calculated by the dose planning program. The FWHM of the commercial He-Ne laser densitometer was less accurate (1.6 and 2.1 mm deviation). Our data show that a diode laser scanning device using a light source emitting 675.2 nm increases the accuracy of a GafChromic MD-55 film readout. This greater accuracy may be related to the diode laser measuring the optical density close to maximum absorption of the GafChromic film MD-55 (671-675 nm).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号