Background Postoperative migration of a joint prosthesis is related to the risk of late loosening. We have previously reported that oral treatment with clodronate reduced migration of the cemented NexGen total knee prosthesis during the first postoperative year, as measured by radiostereometry (RSA). Oral bisphosphonate treatment is sometimes unpleasant, and local treatment will enable higher local concentrations. We now report the results of local peroperative treatment with another bisphosphonate, ibandronate, with the same prosthesis.

Methods This is a double-blind, randomized study of 50 patients using RSA with maximal total point motion (MTPM) as primary effect variable. 1 mg ibandronate (1 mL) or 1 mL saline was applied to the tibial bone surface 1 min before cementation. RSA examination was done on the first postoperative day, and at 6, 12, and 24 months.

Results One ibandronate-treated patient died of unrelated causes, and 1 control patient refused to come for follow-up, leaving 24 patients in each group for analysis. There were no cases of aseptic loosening. By repeated measures ANOVA, migration (MTPM) was reduced by local application of ibandronate (p = 0.006). The effect was most pronounced at 6 months, with a reduction from 0.45 to 0.32 mm (95% CI for reduction: 0.04-0.21 mm). At 12 months, the migration from the postoperative examination was reduced from 0.47 to 0.36 mm (95% CI for reduction: 0.02-0.20 mm). At 24 months, the reduction was from 0.47 to 0.40 mm (95% CI: -0.01-0.16 mm).

Interpretation This is the first study to show improvement of prosthesis fixation by local pharmacological treatment in humans. The treatment appears to be safe, cheap, and easy to perform. However, the improvement in postoperative stability was not greater than with systemic clodronate treatment.  相似文献   

2.
Background In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component.

Material and methods A hemispherical and a nonhemispherical acetabular component were mounted in a phantom. Both acetabular components underwent migration analyses with 3 different RSA systems: conventional RSA using tantalum markers, an RSA system using a hemispherical cup algorithm, and a novel modelbased RSA system.

Results We found narrow confidence intervals, indicating high precision of the conventional marker system and model-based RSA with regard to migration and rotation. The confidence intervals of conventional RSA and model-based RSA were narrower than those of the hemispherical cup algorithm-based system regarding cup migration and rotation.

Interpretation The model-based RSA software combines the precision of the conventional RSA software with the convenience of the hemispherical cup algo-rithm-based system. Based on our findings, we believe that these new tools offer an improvement in the measurement of acetabular component migration.  相似文献   

3.
Background Minor design changes may cause major changes in implant performance. Thus, as part of a stepwise introduction of a new low-profile cup, we performed a randomized trial comparing it to a well-docu-mented standard cup.

Patients and methods 60 patients, stratified according to sex, weight, and age, underwent cemented total hip arthroplasty using a Lubinus SP2 stem with ceramic head and were randomized to either the new low-profile Lubinus Flanged Anti-Luxation cup (FAL) or the Lubinus Standard Eccentric cup (Standard). 7 patients were excluded and 53 (28 FAL) were evaluated at 3, 6, 12, and 36 months postoperatively. Primary outcome variables, cup migration (MTPM), and wear (total 3-dimensional femoral head penetration) were measured with radiostereometry (RSA). Clinical outcome was evaluated with the western Ontario and McMaster osteoarthritis index (Womac) and the visual analog pain score (VAS).

Results We found no difference in migration between the FAL and Standard cups. There was no difference in wear between the two cups and there was no correlation between wear and migration. 3 cups (2 FAL and 1 Standard) showed continuous migration of a magnitude that indicated an increased risk of early loosening. Clinical outcome was excellent, without any difference between the 2 groups.  相似文献   

4.
Background and purpose With Ganz periacetabular osteotomy, the osteotomized acetabular fragment is reoriented in an adducted, extended, and rotated position. The acetabular fragment is fixated with 2 screws and the patients are allowed 30 kg of weight bearing immediately after surgery. We were interested in examining the stability of the reoriented acetabulum after Ganz osteotomy; thus, the migration of the acetabular fragment was assessed by radiostereometry.

Patients and methods 32 dysplastic patients (27 females; 32 hips) were included in the study. Median age was 39 (20-57) years. Radiostereometric examinations were done at 1 week, 4 weeks, 8 weeks and 6 months. Data are presented as mean (SD).

Results 6 months postoperatively, the acetabular fragment had migrated 0.7 (0.8) mm medially, and 0.7 (0.5) mm proximally. Mean rotation in adduction was 0.5° (1.3). In other directions, mean migration was below 0.5 mm/°. There were no statistically significant differences in migration at 8 weeks and 24 weeks postoperatively regarding translation and rotation.

Interpretation Due to the limited amount of migration, we find our postoperative partial weight-bearing regime safe.  相似文献   

5.
Background Acetabular screw cups seem to give high primary stability. We analyzed the migration and loosening behavior of a first-generation screw cup in a longterm follow-up.

Patients and methods We examined 92 uncemented titanium alloy conical screw cups prospectively. Implant migration was assessed with a digital high-precision method (EBRA) with an accuracy of 1.0 mm.

Results After mean 11 (0.5-18) years, 87 patients were available for examination and 5 patients had died. 32 implants had been revised and 7 cases showed radiographic evidence of loosening. The 10-year survival rate was 71%. Migration of more than 1 mm occurred in 53 hips. Implant survival was strongly associated with an annual migration of greater than 0.2 mm.

Interpretation The long-term behavior of this cup is not satisfactory. In spite of extraordinarily high primary implant stability, secondary osseointegration of this cup often fails. The annual migration rate represents a valid parameter for prediction of implant survival.  相似文献   

6.
Background and purpose Implantation of the femoral component at 10-15° of anteversion is recommended in THA. Surgical guidelines suggest that the lower leg be positioned horizontally or vertically with the knee flexed to 90° (figure of four). By constructing a perpendicular axis (a “figure-of-four” axis) to the lower leg, anteversion of the stem is approximated. We assessed whether the figure-of-four axis is a reliable intraoperative tool to approximate the retrocondylar line as a reference for stem version.

Methods Cadavers (21 in total) were placed supine on an operating table and the lower legs were aligned to the horizontal plane. Cannulated titanium screws were inserted perpendicular to the lower leg into the medial epicondyle, representing the figure-of-four axis. The femoral neck axes, retrocondylar lines, and the figure-of-four axes were determined using CT images of the specimen.

Results The anteversion of the femoral neck was median 9.8 (4.5-15.1) degrees (interquartile range). The figure-of-four axis deviated by 0.5 (-2.1-2) degrees, whereas the median difference in the axis in relation to the femoral neck axis was 9.5 (-13.6 to -2) degrees.

Interpretation The figure-of-four axis, being nearly parallel to the retrocondylar line, is a valid indirect method for determination of stem version intraoperatively in patients without varus/valgus deviations of the knee.  相似文献   

7.
Background Recurrent dislocation in total hip replacement is difficult to treat and causes severe morbidity.

Patients and methods 12 patients suffering dislocations were reoperated with a socket wall addition device (anti-luxation ring) for the Lubinus SPII prosthesis, and were followed up after a mean of 4.5 (1-9) years with regard to redislocation, function and radiographic loos-ening.

Results 1 of the patients suffered a redislocation after almost 7 years of use. There was no loosening during the follow-up time. A Harris hip score of 87 (60-100), a health-related quality of life (EQ-5D) index of 0.8 (0.6-1.0) and total range of motion of 145° (125-165) indicate that the patients had a level of function comparable to that of age-matched hip surgery patients with no com-plications.

Interpretation The anti-luxation ring shows promising mid-term results and seems to provide an alternative to more extensive revision surgery for selected patients. ▪  相似文献   

8.
Background Controversy still exists as to whether to mount the tibial bearing on a metal baseplate or not. Furthermore, the tibial component can be either horizontally or completely cemented. We evaluated metal backing versus all-polyethylene using horizontal cementing technique.

Patients and methods We randomized 40 patients with knee arthrosis (40 knees) to 2 groups: cemented total knee arthroplasty (AGC, Biomet) using either all-polyethylene (AP) or metal-backed (MB) tibial compo-nents (n = 20 for each group). All tibial implants had a total thickness of 8 mm. We used proximal cement-ing, including only the horizontal part of the tibia with avoidance of the stem-bone interface.

Results The positioning of the implants, as judged by the HKA angle, showed an average neutral alignment in both groups. Preoperatively and after 2 years, there was no statistically significant difference between the HSS scores in both groups (p = 0.6 and 0.4). After 2 years, the metal-backed components had rotated more around the longitudinal axis, median 0.5° vs. 0.2° (internal or exter-nal rotation, p = 0.002), and showed increased maximum total point motion, median 1.0 vs. 0.4 mm (maximum migration or MTPM, p = 0.003).

Interpretation Our study indicates that better fixation can be obtained with the all-polyethylene design if proximally cemented thin components are used.

  ▪  相似文献   

9.
Background Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabular lysis and thereby loosening.

Patients and methods This was a retrospective cohort study of 119 hips (101 patients) that had the Uncemented Fitmore cup (Sulzer Orthopedics). In 66 patients, the femoral component was CF-30 (Sulzer) used with cement. In the remaining 35 patients, thrust plate prosthesis (TPP) (Sulzer) was used. Of the 101 patients, 94 (112 hips) were available for study. Mean follow-up of the 94 patients was 7 (5-13) years.

Results The mean preoperative Harris hip score was 38 and the mean postoperative Harris hip score was 89 at the last follow-up. Taking aseptic loosening as the endpoint, the survival rate of the Fitmore cup was 100% at 11 years.

Interpretation The uncemented Fitmore acetabular cup with second generation metal-on-metal articulation showed good results with regard to aseptic loosening in the medium term.  相似文献   

10.
Background Aseptic loosening of elbow replacements, seen in long-term follow-up, remains a problem. In this study, we attempted to determine the influence of cementing technique, prosthetic position, different component sizes, use of a bone plug, and intraoperative fractures on the development and progression of radiolucent lines and aseptic loosening.

Methods We studied standard radiographs of 125 primary Souter-Strathclyde total elbow prostheses using the Wrightington method. Additionally, 104 preoperative radiographs were available for analysis. We used a Markow statistical model to detect relationships between all factors described above.

Results After a mean follow-up time of 5.5 (2-19) years, 21 (17%) prostheses had loosened radiographically (10-year survival: 65%). When the humeral component was tilted more medially or more anteriorly, we found development of radiolucent lines at the medial condyle and at the posterior side of the humeral component. However, the progression of these lines was not influenced by these positions. No other prognostic factors for radiolucent lines or aseptic loosening were found.

Interpretation Despite the small number of elbows studied, the weak influence of prosthetic position on aseptic loosening gives more ground for a multifactorial cause for aseptic loosening of the Souter-Strathclyde total elbow prosthesis.  相似文献   

11.
Background Reconstruction of the bone stock and fixation of the implant remain challenging problems in revision surgery. In this retrospective study, we wanted to gain information on initial stability and wear after revision with the Burch-Schneider ring.

Patients and methods Between 1994 and 1998, we performed 70 reconstructions of the acetabulum with a Burch-Schneider ring in revision arthroplasty. 63 patients could be followed up clinically and radiographically. 40 cups were suitable for EBRA measurements whereas migration and wear could not be assessed by this method in 23 cases due to lack of comparability of pelvic radiographs. The mean follow-up time was 4.7 years.

Results 2 cups were re-revised and 14 cups had breakage or changes of position of the screws. 30 cups showed detectable migration and 18 cups detectable wear. The mean migration was 2.8 mm and the mean wear rate was 0.12 mm/year. 16 cups had detectable migration after 1 year; 11 of these 16 continued to migrate and 9 of them had screw breakage. Both re-revisions showed early migration. Early migration correlated with later screw breakage and the overall migration correlated with wear. The only risk factor found for early migration was the wear rate.

Interpretation The Burch-Schneider ring is an established and reliable implant for cup revision with good clinical results, but it seems to be difficult to maintain intraoperative stability. The implants with continuous migration may lead to late clinical failure and require further observation. Wear may contribute to migration and resorption of the bone graft. ▪  相似文献   

12.
Background Concern has been expressed about the large number of radiolucent lines around the ulnar component of the Kudo elbow prosthesis in medium-term follow-up.

Patients and methods We studied the metal-backed cemented ulnar component in 13 Kudo elbow prostheses (type 5) using radiostereometric analysis (RSA). All patients had rheumatoid arthritis. There were 2 men and 9 women with a mean age of 55 years. 2 were operated bilaterally. The metal-backed ulnar component was marked with three 0.8 mm tantalum spheres and the proximal ulna with 5 spheres of 0.8 or 1.0 mm diameter. The initial RSA examination was performed during the first week after the operation. Further examinations were done at 4, 12 and 24 months. Conventional radiographs were taken during the first week postoperatively, and at 12 and 24 months.

Results Translations (medial/lateral, antero/poste-rior and proximal/distal) were less than 0.5 mm in all but 1 patient who had a maximal translation of 3.4 mm distally. The mean rotations around all three axes were less than 0.4 degrees. The patient who had a translation of 3.4 mm also had varus angulation exceeding 4 degrees. This patient also had progressive circumferential radiolucent lines on conventional radiographs. The Mayo elbow score increased from 40 (25-65) before surgery to 92 (45-100) at 2 years.

Interpretation The fixation of the metal-backed ulnar component of the Kudo elbow prosthesis at 2 years is good.  相似文献   

13.
Background and purpose Increased intradiscal pressure and relative segmental hypermobility are in vitro observations supporting the idea of increased postoperative load being a reason for progressive degeneration of the free mobile segment adjacent to a lumbar fusion. These mechanisms have been difficult to confirm in clinical studies, and an alternative theory claims instead that the adjacent segment degeneration follows a natural degenerative course in patients who are predisposed. We examined 9 patients 5 years after lumbar fusion, to assess whether relative hypermobility of the segment adjacent to fusion could be correlated to progressive degeneration of the same segment.

Patients and methods The 9 patients, all of whom had been treated with a lumbar fusion after a preoperative intervertebral mobility assessment by spinal RSA, were re-examined 5 years after surgery. The intervertebral translations of the vertebra proximal to the fusion were determined by RSA and compared to the mobility of the same lumbar segment before fusion. The disc height and any progressive reduction at the two levels proximal to the one fused were measured on conventional radiographs.

Results Adjacent segment mobility 5 years after fusion—expressed as mean transverse, vertical, and sagittal translation of the vertebra proximal to fusion— was not significantly changed compared to the mobility measured before surgery. Increased mobility of the segment seen in 5 individual patients was not associated with progressive degeneration of the same segment or to a poor clinical outcome.

Interpretation Hypermobility of the segment adjacent to fusion is not a general finding. Increased mobility that can be seen in certain individuals does not impair the 5-year result. The significance of mechanical alterations in adjacent segment degeneration is uncertain, and it is possibly overestimated.  相似文献   

14.
Background Degree of satisfaction with a knee arthroplasty is said to be correlated to reduced pain and better function. During a validation of the Swedish Knee Arthroplasty Register in 1997, previously operated patients were asked how satified they were with their knee. A subgroup of “satisfied” patients was identified who underwent revision within 2 years of having expressed satisfaction. Our aim was to study the revision diagnosis, to determine whether the problem leading to revision had been discovered as a result of routine follow-up, and also to find out when the symptoms leading to revision had started.

Methods We retrospectively studied the medical records of 181 patients (181 knees), with a median age of 74 (31-88) years. 68% were women and the median time between primary operation and revision was 8 (3-21) years.

Results Aseptic loosening (74/181) was the most common diagnosis. 2 cases were revised as a result of routine follow-up. 44% of the medical records included reports of pain in the replaced knee prior to answering the satisfaction questionnaire.

Interpretation Few patients were admitted to knee revision surgery due to medical findings discovered during routine follow-up. The term “satisfaction” must be interpreted with care, as it seems to have a more complex meaning for the patients than absence of knee pain.

  ▪  相似文献   

15.
Background The purposes of this study were (1) to evaluate the wear pattern of the hydroxyapatite-coated “Dual Radius” Omnifit cup, (2) to investigate whether wear is correlated to any demographic or prosthesis-related factors, and (3) to describe micromotion of both the cup and the stem.

Patients and methods 154 hips were implanted between 1990 and 1996 and followed for an average of 6 years. Wear was measured according to the “Charnley-duo” method and, in 79 hips, with radiostereometry (RSA). RSA was also used to evaluate micromotion. We analyzed the femoral heads using scanning electron microscopy, energy dispersive X-ray spectroscopy and an atomic force microscope.

Result 66 cups were revised and had a mean annual wear of 0.32 mm compared to 0.12 mm in hips not revised. Osteolytic processes were observed in 35 hips but at revision osteolysis was present in 51 cases. 43/66 sockets were loose. Micromotion evaluated by RSA, weight, age, side, size of cup, screws, polyethylene thickness or shelf-life of the polyethylene did not correlate to wear, whereas male gender did.

Interpretation It is still unclear why about half of our cases had an abnormal wear rate. Annual wear exceeding 0.2 mm is prognostic of late failure and should be considered a warning sign.  相似文献   

16.
Introduction Bisphosphonates have been proposed to delay or prevent loosening of joint replacement implants by reducing bone resorption. It is known, however, that implant motion prevents the bone anchorage necessary to maintain secure implant fixation.

Methods We used our experimental implant model with controlled motion to evaluate the relative effects of implant motion and bisphosphonate. We implemented our established 8-week experimental revision protocol to obtain a bony and soft tissue setting of revision joint replacement in 16 dogs. At 8 weeks, we had stabilized half of the implants. The other half of the implants continued pistoning. Half of the dogs were exposed to alendronate (oral).

Results Stabilization of the revision implant was more effective at improving fixation (higher shear strength) than administering alendronate. As expected, the fibrous membrane remained under unstable conditions, even with alendronate. With alendronate and stabilized implants, increased bone was observed near the sclerotic shell of the revision cavity, but it was reduced with alendronate when the implant was unstable.

Interpretation Our findings suggest that it may be difficult for alendronate administration alone to rescue implants that are already loose. In implants that have not progressed to loosening, alendronate may increase bone density at the border with the sclerotic shell, but the effect of this bone in delaying eventual loosening is not known.  相似文献   

17.
Background Overweight and a high level of physical activity are known risk factors for loosening of a total hip arthroplasty (THA) due to primary osteoarthritis. We wanted to investigate how these factors, together with age and sex, affect the risk of revision surgery.

Patients and methods We matched data from the Norwegian Arthroplasty Register with information on risk factors collected at a cardiovascular screening. We identified 1,535 primary THAs in the screened cohort (930 cemented implants using well-documented cement). Of the participants included, 969 were female. Mean age at screening was 49 years, at primary THA 63 years, and 69 years at the end of follow-up. We used Cox regression analysis to estimate relative risks (RRs). Event was defined as implant revision due to aseptic loosening of cup, stem or both. Follow-up was time from primary THA to event or censoring.

Results Men were at greater risk than women of loosening of the femoral stem (RR 2.0, 95% CI 1.3-3.2). Both men and women with upper-quartile body weight were at increased risk of revision due to loosening of the stem (RR 2.5 and 2.7, respectively). Men with a high level of physical activity during leisure time were at increased risk of revision due to loosening of the cup (RR 4.8, 95% CI 1.3-18). In the multivariate model with adjustment for activity, there was little association between age at primary THA and risk of revision due to loosening.

Interpretation We found that body weight and physical activity recorded long before THA affected the survival of total hip arthroplasties. Controlling for these variables weakened the association between age at primary surgery and aseptic loosening. Men had an increased risk of loosening of the femoral stem, also after controlling for lifestyle factors.  相似文献   

18.
Background The outcome of femoral component revision with either cemented or proximally coated stems has been disappointing, but revision with extensively coated stems has been promising. We report long-term outcome of a grit-blasted titanium stem entirely plasma sprayed with hydroxyapatite (HA), in femoral revision surgery.

Patients and methods During 1988 to 1993, we performed 66 femoral revisions in 65 patients (49 women) aged mean 58 (28-86) years. 3 patients died before the 10-year follow-up and 4 did not come for the follow-up examination because they had no hip problems, as confirmed by telephone and by a written reply. 1 of these, however, was previously controlled at 10 years. Thus, 59 patients (60 hips) were followed by clinical and radiographic analysis for 10-16 years after femoral stem revision.

Results 1 stem was re-revised due to mechanical failure, and none were revised because of infection. We noticed a low degree of proximal bone loss and a low incidence of distal bone hypertrophy. These observations indicate no significant net transfer of stress proximally to distally, and a somewhat physiological weight distribution from the stem to the femoral bone. The bone changes confirmed a well-fixed femoral component in asymptomatic patients.

Interpretation Our findings indicate good long-term results with a fully HA-coated stem in femoral revision surgery. ▪  相似文献   

19.
Background The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA).

Patients and methods Using the Danish Hip Arthroplasty Registry (DHR), we identified patients less than 70 years old who had undergone uncemented primary THA during 1997-2005. 4,125 HA-coated and 7,737 non-HA-coated cups and 3,158 HA-coated and 4,749 non-HA-coated stems were available for analysis. The mean follow-up time was 3.4 years for cups and 3.2 years for stems. We estimated the relative risk (RR) of revision due to aseptic loosening or any cause, and adjusted for possible confounders (age, sex, fixation of opposite implant part, and diagnosis for primary THA) using multivariate Cox regression analysis.

Results The adjusted RRs for revision of HA-coated cups and stems due to aseptic loosening were 0.89 (95%CI: 0.37-2.2) and 0.71 (95%CI: 0.27-1.9) with up to 9 years of follow-up, compared to non-HA-coated implants. When taking all causes of revision into consideration, the risk estimates were 0.85 (95%CI: 0.68-1.1) and 0.81 (95%CI: 0.61-1.1) for HA-coated cups and stems, respectively.

Interpretation In this medium-term follow-up study, the use of HA-coated implants was not associated with any clearly reduced overall risk of revision compared to non-HA-coated implants.  相似文献   

20.
Background The initial stability of an exchanged hip arthroplasty is crucial for the survival of the revised joint. Several factors can affect the outcome. The amount of liquid in morsellized bone has a major influence on the constrained stiffness properties of impacted bone applied in revision joint surgery.

Method To determine whether water or fat is the main contributing liquid, we performed an experimental study on impacted morsellized cortico-cancellous bovine bone to compare the constrained e-moduli in native bone and bone with modified water and fat content. The bone was impacted into bone pellets by a standardized method by which the construction procedure was monitored. Other stiffness properties were recorded during subsequent load testing.

Results Low water content significantly increased the constrained stiffness moduli during load, while high water content significantly reduced it. Low fat content increased stiffness significantly only during the initial phase of loading.

Interpretation Our findings indicate that the preparation and usage of morsellized bone in revision joint surgery should be performed under dry conditions to improve the initial stability of the revised prosthesis. ▪  相似文献   