首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
It is often difficult for clinicians to decide correctly on either biopsy or follow-up for breast lesions with masses on ultrasonographic images. The purpose of this study was to develop a computerized determination scheme for histological classification of breast mass by using objective features corresponding to clinicians’ subjective impressions for image features on ultrasonographic images. Our database consisted of 363 breast ultrasonographic images obtained from 363 patients. It included 150 malignant (103 invasive and 47 noninvasive carcinomas) and 213 benign masses (87 cysts and 126 fibroadenomas). We divided our database into 65 images (28 malignant and 37 benign masses) for training set and 298 images (122 malignant and 176 benign masses) for test set. An observer study was first conducted to obtain clinicians’ subjective impression for nine image features on mass. In the proposed method, location and area of the mass were determined by an experienced clinician. We defined some feature extraction methods for each of nine image features. For each image feature, we selected the feature extraction method with the highest correlation coefficient between the objective features and the average clinicians’ subjective impressions. We employed multiple discriminant analysis with the nine objective features for determining histological classification of mass. The classification accuracies of the proposed method were 88.4 % (76/86) for invasive carcinomas, 80.6 % (29/36) for noninvasive carcinomas, 86.0 % (92/107) for fibroadenomas, and 84.1 % (58/69) for cysts, respectively. The proposed method would be useful in the differential diagnosis of breast masses on ultrasonographic images as diagnosis aid.  相似文献   

2.
Although magnetic resonance imaging (MRI) has a higher sensitivity of early breast cancer than mammography, the specificity is lower. The purpose of this study was to develop a computer-aided diagnosis (CAD) scheme for distinguishing between benign and malignant breast masses on dynamic contrast material-enhanced MRI (DCE-MRI) by using a deep convolutional neural network (DCNN) with Bayesian optimization. Our database consisted of 56 DCE-MRI examinations for 56 patients, each of which contained five sequential phase images. It included 26 benign and 30 malignant masses. In this study, we first determined a baseline DCNN model from well-known DCNN models in terms of classification performance. The optimum architecture of the DCNN model was determined by changing the hyperparameters of the baseline DCNN model such as the number of layers, the filter size, and the number of filters using Bayesian optimization. As the input of the proposed DCNN model, rectangular regions of interest which include an entire mass were selected from each of DCE-MRI images by an experienced radiologist. Three-fold cross validation method was used for training and testing of the proposed DCNN model. The classification accuracy, the sensitivity, the specificity, the positive predictive value, and the negative predictive value were 92.9% (52/56), 93.3% (28/30), 92.3% (24/26), 93.3% (28/30), and 92.3% (24/26), respectively. These results were substantially greater than those with the conventional method based on handcrafted features and a classifier. The proposed DCNN model achieved high classification performance and would be useful in differential diagnoses of masses in breast DCE-MRI images as a diagnostic aid.  相似文献   

3.
The accuracy of an ultrasound (US) computer-aided diagnosis (CAD) system was evaluated for the classification of BI-RADS category 3, probably benign masses. The US database used in this study contained 69 breast masses (21 malignant and 48 benign masses) that at blinded retrospective interpretation were assigned to BI-RADS category 3 by at least one of five radiologists. For computer-aided analysis, multiple morphology (shape, orientation, margin, lesions boundary, and posterior acoustic features) and texture (echo patterns) features based on BI-RADS lexicon were implemented, and the binary logistic regression model was used for classification. The receiver operating characteristic curve analysis was used for statistical analysis. The area under the curve (Az) of morphology, texture, and combined features were 0.90, 0.75, and 0.95, respectively. The combined features achieved the best performance and were significantly better than using texture features only (0.95 vs. 0.75, p value?=?0.0163). The cut-off point at the sensitivity of 86 % (18/21), 95 % (20/21), and 100 % (21/21) achieved the specificity of 90 % (43/48), 73 % (35/48), and 33 % (16/48), respectively. In conclusion, the proposed CAD system has the potential to be used in upgrading malignant masses misclassified as BI-RADS category 3 on US by the radiologists.  相似文献   

4.
Dynamic contrast material-enhanced magnetic resonance imaging (DCE-MRI) of breasts is an important imaging modality in breast cancer diagnosis with higher sensitivity but relatively lower specificity. The objective of this study is to investigate a new approach to help improve diagnostic performance of DCE-MRI examinations based on the automated detection and analysis of bilateral asymmetry of characteristic kinetic features between the left and right breast. An image dataset involving 130 DCE-MRI examinations was assembled and used in which 80 were biopsy-proved malignant and 50 were benign. A computer-aided diagnosis (CAD) scheme was developed to segment breast areas depicted on each MR image, register images acquired from the sequential MR image scan series, compute average contrast enhancement of all pixels in one breast, and a set of kinetic features related to the difference of contrast enhancement between the left and right breast, and then use a multi-feature based Bayesian belief network to classify between malignant and benign cases. A leave-one-case-out validation method was applied to test CAD performance. The computed area under a receiver operating characteristic (ROC) curve is 0.78 ± 0.04. The positive and negative predictive values are 0.77 and 0.64, respectively. The study indicates that bilateral asymmetry of kinetic features between the left and right breasts is a potentially useful image biomarker to enhance the detection of angiogenesis associated with malignancy. It also demonstrates the feasibility of applying a simple CAD approach to classify between malignant and benign DCE-MRI examinations based on this new image biomarker.  相似文献   

5.
6.
OBJECTIVE: In this work, methods utilizing supervised and unsupervised machine learning are applied to analyze radiologically derived morphological and calculated kinetic tumour features. The features are extracted from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) time-course data. MATERIAL: The DCE-MRI data of the female breast are obtained within the UK Multicenter Breast Screening Study. The group of patients imaged in this study is selected on the basis of an increased genetic risk for developing breast cancer. METHODS: The k-means clustering and self-organizing maps (SOM) are applied to analyze the signal structure in terms of visualization. We employ k-nearest neighbor classifiers (k-nn), support vector machines (SVM) and decision trees (DT) to classify features using a computer aided diagnosis (CAD) approach. RESULTS: Regarding the unsupervised techniques, clustering according to features indicating benign and malignant characteristics is observed to a limited extend. The supervised approaches classified the data with 74% accuracy (DT) and providing an area under the receiver-operator-characteristics (ROC) curve (AUC) of 0.88 (SVM). CONCLUSION: It was found that contour and wash-out type (WOT) features determined by the radiologists lead to the best SVM classification results. Although a fast signal uptake in early time-point measurements is an important feature for malignant/benign classification of tumours, our results indicate that the wash-out characteristics might be considered as important.  相似文献   

7.
8.
Computerized methods have recently shown a great potential in providing radiologists with a second opinion about the visual diagnosis of the malignancy of mammographic masses. The computer-aided diagnosis (CAD) system we developed for the mass characterization is mainly based on a segmentation algorithm and on the neural classification of several features computed on the segmented mass. Mass-segmentation plays a key role in most computerized systems. Our technique is a gradient-based one, showing the main characteristic that no free parameters have been evaluated on the data set used in this analysis, thus it can directly be applied to data sets acquired in different conditions without any ad hoc modification. A data set of 226 masses (109 malignant and 117 benign) has been used in this study. The segmentation algorithm works with a comparable efficiency both on malignant and benign masses. Sixteen features based on shape, size and intensity of the segmented masses are extracted and analyzed by a multi-layered perceptron neural network trained with the error back-propagation algorithm. The capability of the system in discriminating malignant from benign masses has been evaluated in terms of the receiver-operating characteristic (ROC) analysis. A feature selection procedure has been carried out on the basis of the feature discriminating power and of the linear correlations interplaying among them. The comparison of the areas under the ROC curves obtained by varying the number of features to be classified has shown that 12 selected features out of the 16 computed ones are powerful enough to achieve the best classifier performances. The radiologist assigned the segmented masses to three different categories: correctly-, acceptably- and non-acceptably-segmented masses. We initially estimated the area under ROC curve only on the first category of segmented masses (the 88.5% of the data set), then extending the classification to the second subclass (reaching the 97.8% of the data set) and finally to the whole data set, obtaining A(z)=0.805+/-0.030, 0.787+/-0.024 and 0.780+/-0.023, respectively.  相似文献   

9.
目的探讨3.0 T超导型MRI灌注加权成像(PWI)联合动态增强扫描(DCE)在乳腺早期良恶性病变鉴定中的价值。方法选择术后经病理确诊为良恶性的乳腺早期病变女性患者61例,年龄24~65岁,平均年龄30.12岁。所有患者均经3.0 T超导型MRI PWI常规T2加权成像(T2WI)和T1加权成像(T1WI)平扫后行三维(3D)动态增强扫描技术,并根据病理结果分为恶性病变和良性病变,对比病变形态学变化、时间-信号强度曲线(TIC)及表观弥散系数(ADC)值,并分析PWI联合DCE对乳腺早期良恶性病变鉴别诊断价值。结果病理结果为恶性病变27例,良性病变34例;DCE-MRI扫描结果为恶性病变患者20例,良性病变患者26例,病变检出率75.41%;PWI扫描结果为恶性病变患者21例,良性病变患者27例,病变检出率78.69%。乳腺早期良性病变形态以类圆形(76.5%)、边缘以光滑(70.6%)为主,乳腺早期恶性病变形态以分叶形(63.0%)、边缘以毛刺征(59.3%)为主;乳腺早期良恶性病变DCE-MRI扫描形态学特征对比,差异有显著统计学意义(χ^2=43.557、37.459,P=0.000、0.000)。乳腺早期良性病变TIC形态以Ⅰ型(61.8%)为主,乳腺早期恶性病变TIC形态以Ⅲ型(77.8%)为主,两者比较,差异有显著统计学意义(χ^2=121.852,P=0.000);22例(81.5%)恶性病变患者ADC值≤1.195×10-3 mm2/s,28例(82.4%)良性病变患者ADC值>1.195×10-3 mm2/s,两者差异有显著统计学意义(χ2=26.148,P=0.000)。二者联合鉴别诊断乳腺早期良恶性病变的灵敏度、特异度及准确度与DCE-MRI、PWI单一诊断更高(P<0.05)。结论 3.0 T超导型MRI PWI联合DCE在乳腺早期良恶性病变鉴定中具有较高的临床价值。  相似文献   

10.
Among gynecological malignancies, ovarian cancer is the most frequent cause of death. Image mining algorithms have been predominantly used to give the physicians a more objective, fast, and accurate second opinion on the initial diagnosis made from medical images. The objective of this work is to develop an adjunct computer-aided diagnostic technique that uses 3D ultrasound images of the ovary to accurately characterize and classify benign and malignant ovarian tumors. In this algorithm, we first extract features based on the textural changes and higher-order spectra information. The significant features are then selected and used to train and evaluate the decision tree (DT) classifier. The proposed technique was validated using 1,000 benign and 1,000 malignant images, obtained from ten patients with benign and ten with malignant disease, respectively. On evaluating the classifier with tenfold stratified cross validation, the DT classifier presented a high accuracy of 97 %, sensitivity of 94.3 %, and specificity of 99.7 %. This high accuracy was achieved because of the use of the novel combination of the four features which adequately quantify the subtle changes and the nonlinearities in the pixel intensity variations. The rules output by the DT classifier are comprehensible to the end-user and, hence, allow the physicians to more confidently accept the results. The preliminary results show that the features are discriminative enough to yield good accuracy. Moreover, the proposed technique is completely automated, accurate, and can be easily written as a software application for use in any computer.  相似文献   

11.
The purpose of this study was to develop a knowledge-based scheme for the detection of masses on digitized screening mammograms. The computer-assisted detection (CAD) scheme utilizes a knowledge databank of mammographic regions of interest (ROIs) with known ground truth. Each ROI in the databank serves as a template. The CAD system follows a template matching approach with mutual information as the similarity metric to determine if a query mammographic ROI depicts a true mass. Based on their information content, all similar ROIs in the databank are retrieved and rank-ordered. Then, a decision index is calculated based on the query's best matches. The decision index effectively combines the similarity indices and ground truth of the best-matched templates into a prediction regarding the presence of a mass in the query mammographic ROI. The system was developed and evaluated using a database of 1465 ROIs extracted from the Digital Database for Screening Mammography. There were 809 ROIs with confirmed masses (455 malignant and 354 benign) and 656 normal ROIs. CAD performance was assessed using a leave-one-out sampling scheme and Receiver Operating Characteristics analysis. Depending on the formulation of the decision index, CAD performance as high as A(zeta) = 0.87 +/- 0.01 was achieved. The CAD detection rate was consistent for both malignant and benign masses. In addition, the impact of certain implementation parameters on the detection accuracy and speed of the proposed CAD scheme was studied in more detail.  相似文献   

12.
This study aimed to investigate a computer-aided system for detecting breast masses using dynamic contrast-enhanced magnetic resonance imaging for clinical use. Detection performance of the system was analyzed on 61 biopsy-confirmed lesions (21 benign and 40 malignant lesions) in 34 women. The breast region was determined using the demons deformable algorithm. After the suspicious tissues were identified by kinetic feature (area under the curve) and the fuzzy c-means clustering method, all breast masses were detected based on the rotation-invariant and multi-scale blob characteristics. Subsequently, the masses were further distinguished from other detected non-tumor regions (false positives). Free-response operating characteristics (FROC) curve and detection rate were used to evaluate the detection performance. Using the combined features, including blob, enhancement, morphologic, and texture features with 10-fold cross validation, the mass detection rate was 100 % (61/61) with 15.15 false positives per case and 91.80 % (56/61) with 4.56 false positives per case. In conclusion, the proposed computer-aided detection system can help radiologists reduce inter-observer variability and the cost associated with detection of suspicious lesions from a large number of images. Our results illustrated that breast masses can be efficiently detected and that enhancement and morphologic characteristics were useful for reducing non-tumor regions.  相似文献   

13.
The accuracy of computer-aided diagnosis (CAD) for early detection and classification of breast cancer in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is dependent upon the features used by the CAD classifier. Here, we show that fast orthogonal search (FOS), which provides a more efficient iterative manner of computing stepwise regression feature selection, can select features with predictive value from a set of kinetic and texture candidate features computed from dynamic contrast-enhanced magnetic resonance images. FOS can in minutes search candidate feature sets of millions of terms, which may include cross-products of features up to second-, third- or fourth-order. This method is tested on a set of 83 DCE-MRI images, of which 20 are for cancerous and 63 for benign cases, using a leave-one-out trial. The features selected by FOS were used in a FOS predictor and nearest-neighbour predictor and had an area under the receiver operating curve (AUC) of 0.889 and 0.791 respectively. The FOS predictor AUC is significantly improved over the signal enhancement ratio predictor with an AUC of 0.706 (p = 0.0035 for the difference in the AUCs). Moreover, using FOS-selected features in a support vector machine increased the AUC over that resulting when the features were manually selected.  相似文献   

14.
Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based Az value of 0.83 +/- 0.01. The improvement compared to the previous CAD system was statistically significant (p = 0.02). When patient age was included in the new CAD system, view-based and case-based Az values were 0.85 +/- 0.01 and 0.87 +/- 0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening mammography with 132 benign and 197 malignant ROIs containing masses achieved a view-based Az value of 0.84 +/- 0.02.  相似文献   

15.
A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, mammographic presentation, lesion size, and results of histopathological examination. The overall sensitivity of CAD was 91 % (139 of 152 cases). CAD detected 100 % (47/47) of cancers manifested as microcalcifications; 98 % (62/63) of those manifested as non-calcified masses; 100 % (15/15) of those manifested as mixed masses and microcalcifications; 75 % (12/16) of those manifested as architectural distortions, and 69 % (18/26) of those manifested as focal asymmetry. CAD sensitivity was 83 % (10/12) for cancers measuring 1–10 mm, 92 % (37/40) for those measuring 11–20 mm, and 92 % (92/100) for those measuring >20 mm. There was no significant difference in CAD detection efficiency between cancers in dense breasts (88 %; 69/78) and those in non-dense breasts (95 %; 70/74). CAD showed a high sensitivity of 91 % (139/152) for the mammographic appearance of cancer and 100 % sensitivity for identifying cancers manifested as microcalcifications. Sensitivity was not influenced by breast density or lesion size. CAD should be effective for helping radiologists detect breast cancer at an earlier stage.  相似文献   

16.
In previous research, we have developed a computer-aided detection (CAD) system designed to detect masses in mammograms. The previous version of our system employed a simple but imprecise method to localize the masses. In this research, we present a more robust segmentation routine for use with mammographic masses. Our hypothesis is that by more accurately describing the morphology of the masses, we can improve the CAD system's ability to distinguish masses from other mammographic structures. To test this hypothesis, we incorporated the new segmentation routine into our CAD system and examined the change in performance. The developed iterative, linear segmentation routine is a gray level-based procedure. Using the identified regions from the previous CAD system as the initial seeds, the new segmentation algorithm refines the suspicious mass borders by making estimates of the interior and exterior pixels. These estimates are then passed to a linear discriminant, which determines the optimal threshold between the interior and exterior pixels. After applying the threshold and identifying the object's outline, two constraints on the border are applied to reduce the influence of background noise. After the border is constrained, the process repeats until a stopping criterion is reached. The segmentation routine was tested on a study database of 183 mammographic images extracted from the Digital Database for Screening Mammography. Eighty-three of the images contained 50 malignant and 50 benign masses; 100 images contained no masses. The previously developed CAD system was used to locate a set of suspicious regions of interest (ROIs) within the images. To assess the performance of the segmentation algorithm, a set of 20 features was measured from the suspicious regions before and after the application of the developed segmentation routine. Receiver operating characteristic (ROC) analysis was employed on the ROIs to examine the discriminatory capabilities of each individual feature before and after the segmentation routine. A statistically significant performance increase was found in many of the individual features, particularly those describing the mass borders. To examine how the incorporation of the segmentation routine affected the performance of the overall CAD system, free-response ROC (FROC) analysis was employed. When considering only malignant masses, the FROC performance of the system with the segmentation routine appeared better than the previous system. When detecting 90% of the malignant masses, the previous system achieved 4.9 false positives per image (FPpI) compared to the post-segmentation system's 4.2 FPpI. At 80% sensitivity, the respective FPpI were 3.5 and 1.6.  相似文献   

17.
In this study, we developed and tested a new multiview-based computer-aided detection (CAD) scheme that aims to maintain the same case-based sensitivity level as a single-image-based scheme while substantially increasing the number of masses being detected on both ipsilateral views. An image database of 450 four-view examinations (1800 images) was assembled. In this database, 250 cases depicted malignant masses, of which 236 masses were visible on both views and 14 masses were visible only on one view. First, we detected suspected mass regions depicted on each image in the database using a single-image-based CAD. For each identified region (with detection score > or = 0.55), we then identified a matching strip of interest on the ipsilateral view based on the projected distance to the nipple along the centerline. By lowering CAD operating threshold inside the matching strip, we searched for a region located inside the strip and paired it with the original region. A multifeature-based artificial neural network scored the likelihood of the paired "matched" regions representing true-positive masses. All single (unmatched) regions except for those either with very high detection scores (> or = 0.85) or those located near the chest wall that cannot be matched on the other view were discarded. The original single-image-based CAD scheme detected 186 masses (74.4% case-based sensitivity) and 593 false-positive regions. Of the 186 identified masses, 91 were detected on two views (48.9%) and 95 were detected only on one view (51.1%). Of the false-positive detections, 54 were paired on the ipsilateral view inside the corresponding matching strips and the remaining 485 were not, which represented 539 case-based false-positive detections (0.3 per image). Applying the multiview-based CAD scheme, the same case-based sensitivity was maintained while cueing 169 of 186 masses (90.9%) on both views and at the same time reducing the case-based false-positive detection rate by 23.7% (from 539 to 411). The study demonstrated that the new multiview-based CAD scheme could substantially increase the number of masses being cued on two ipsilateral views while reducing the case-based false-positive detection rate.  相似文献   

18.
Computer-aided diagnosis (CAD) systems are software programs that use algorithms to find patterns associated with breast cancer on breast magnetic resonance imaging (MRI). The most commonly used CAD systems in the USA are CADstream (CS) (Merge Healthcare Inc., Chicago, IL) and DynaCAD for Breast (DC) (Invivo, Gainesville, FL). Our primary objective in this study was to compare the CS and DC breast MRI CAD systems for diagnostic accuracy and postprocessed image quality. Our secondary objective was to compare the evaluation times of radiologists using each system. Three radiologists evaluated 30 biopsy-proven malignant lesions and 29 benign lesions on CS and DC and rated the lesions’ malignancy status using the Breast Imaging Reporting and Data System. Image quality was ranked on a 0–5 scale, and mean reading times were also recorded. CS detected 70 % of the malignant and 32 % of the benign lesions while DC detected 81 % of the malignant lesions and 34 % of the benign lesions. Analysis of the area under the receiver operating characteristic curve revealed that the difference in diagnostic performance was not statistically significant. On image quality scores, CS had significantly higher volume rendering (VR) (p < 0.0001) and motion correction (MC) scores (p < 0.0001). There were no statistically significant differences in the remaining image quality scores. Differences in evaluation times between DC and CS were also not statistically significant. We conclude that both CS and DC perform similarly in aiding detection of breast cancer on MRI. MRI CAD selection will likely be based on other factors, such as user interface and image quality preferences, including MC and VR.  相似文献   

19.
This study addresses the clinical problem of the patient with breast cancer that has been operated on for an ovarian mass. It specifies the spectrum of histopathologic diagnoses and the differentiating magnetic resonance imaging (MRI) features of ovarian masses with correlations between clinical features, histopathologic, and MRI findings. Sensitivity and specificity of MRI vs histopathology in diagnosing malignancy are estimated. The study included 53 women with breast cancer who underwent surgery for an ovarian mass. Complete medical records, US and MRI images for the ovarian mass, and histopathology slides of both breast and ovarian resection specimens were reviewed and analyzed retrospectively. Thirty-six (67.9 %) patients had benign masses, and 17 (32.1%) had malignant masses, of which 8 (15.1%) were primary ovarian malignancies and 9 (17%) were metastatic from breast carcinomas. There was a significant association between benign and primary malignant ovarian masses and stage II breast cancer (P = .00). There was a significant association between metastatic ovarian masses and stage III to IV breast disease (P = .00) and negative estrogen receptor status (P = .05). Magnetic resonance imaging had a specificity of 91.7% and a sensitivity of 94.1% in diagnosing malignant ovarian masses. In conclusion, the spectrum of ovarian masses diagnosed in patients with breast cancer is broad, including benign lesions, primary ovarian malignancies, and breast metastases. Knowledge of the imaging features may allow a specific diagnosis aiding in surgical planning. Despite the high specificity and sensitivity of MRI to differentiate benign from malignant lesions, the unique ability to differentiate between primary and metastatic malignancies is conserved to histopathology.  相似文献   

20.
The problem of computer-aided classification of benign and malignant breast masses using shape features is addressed. The aim of the study is to look at the exceptions in shapes of masses such as circumscribed malignant tumours and spiculated benign masses which are difficult to classify correctly using common shape analysis methods. The proposed methods of shape analysis treat the object's boundary in terms of local details. The boundaries of masses analysed using the proposed methods were manually drawn on mammographic images by an expert radiologist (JELD). A boundary segmentation method is used to separate major portions of the boundary and to label them as concave or convex segments. To analyse the shape information localised in each segment, features are computed through an iterative procedure for polygonal modelling of the mass boundaries. Features are based on the concavity fraction of a mass boundary and the degree of narrowness of spicules as characterised by a spiculation index. Two features comprising spiculation index (SI) and fractional concavity (fcc) developed in the present study when used in combination with the global shape feature of compactness resulted in a benign/malignant classification accuracy of 82%, with an area (Az) of 0.79 under the receiver operating characteristics (ROC) curve with a database of the boundaries of 28 benign masses and 26 malignant tumours. SI alone resulted in a classification accuracy of 80% with Az of 0.82. The combination of all the three features achieved 91% accuracy of circumscribed versus spiculated classification of masses based on shape.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏