首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Poor rotation of the tibial component is associated with unfavorable total knee arthroplasty outcomes. Some surgeons utilize the tibial tubercle (TT method), while others utilize the femoral cam (Box method) as a rotational landmark during total knee arthroplasty. Our purpose is to determine the reproducibility of 2 methods for establishing intra-operative tibial component rotation, while also comparing the effect of level of training.

Methods

Twelve surgeons positioned and sized a symmetric tibial component on 7 cadaver knees. Surgeons were allowed to utilize their preferred method for establishing tibial component rotation. Seven surgeons selected the TT method, 4 utilized the Box method, and 1 used both methods depending on the specimen. Repeat measurements were completed by each surgeon after a rest period. The differences between tibial tray positions were assessed using computer-assisted optoelectronic measurements. Intra-class correlation coefficients were calculated to determine inter-observer agreement (IOA) and intra-rater reliability (IRR).

Results

Overall, both the Box method and the TT method demonstrated high IRR for tibial component rotation. Experienced surgeons were more consistent at establishing component rotation regardless of technique. Trainees were more consistent when utilizing the Box method (IRR 0.96, IOA 0.94) than the TT method (IRR 0.71, IOA 0.72).

Conclusion

Surgeon experience influences the agreement and reliability of tibial component position. For less experienced surgeons, the Box method was more effective than the TT method for consistently reproducing tibial component rotation.  相似文献   

2.

Background

The purpose of this study is to clarify interobserver and intraobserver reliabilities of the three-dimensional (3D) templating of total hip arthroplasty (THA).

Methods

We selected preoperative computed tomography from 60 hips in 46 patients (14 men and 32 women) who underwent primary THA. To evaluate interobserver and intraobserver reliability, 6 orthopedic surgeons performed 3D templating twice over a 4-week interval. We investigated intraclass correlation coefficients (ICCs) and percent agreement of component size and alignment, comparing morphological differences in the hip. Reproducibility was also compared between groups with osteoarthritis (OA) and those with osteonecrosis (ON).

Results

The interobserver reliabilities for mean cup size and stem size were excellent, with ICC = 0.907 and 0.944, respectively. The value was significantly higher in the ON group than in the OA group. In the OA group, the reliability of cup size and alignment decreased in hips with severe subluxation. Percent agreement of stem size was significantly different between the shapes of femoral canal. For intraobserver reliability, the mean ICC of cup size was 0.965 overall, while the value in the ON group was significantly higher than in the OA group. The mean ICC of stem size was 0.972 overall.

Conclusion

Computed tomography–based 3D templating showed excellent reliability for component size and alignment in THA. Deformity of the affected joint influenced the reliability of preoperative planning.  相似文献   

3.
4.
There is a renewed interest in cementless total knee arthroplasty (TKA) due to improved biomaterials, desire for decreased surgical times and the potential increased longevity. Seventy-three cementless TKAs (AGC, Biomet, Warsaw, Ind) were performed from 1984 to 1986. All components were implanted without cement and without screws and obtained minimum 10 years of follow-up. No patient was lost to follow-up. Fifteen failures occurred, including 12 failed metal-backed patellae, and survivorship for aseptic loosening of any component was 76.4% at 20 years. Two tibial components failed of aseptic loosening at 1.1 and 2.2 years. Excluding patella failures, the survivorship for the cementless tibial component was 96.8% at 20 years. There were no femoral component failures. After eliminating patella failures, this cementless monoblock tibial component without screws demonstrated excellent 20-year survivorship.  相似文献   

5.
The optimal amount of patellar component medialization in knee arthroplasty is unknown. We measured the impact, on patellofemoral kinematics and contact force distribution, of 0.0-, 2.5-, and 5.0-mm patellar component medialization in 7 cadaveric specimens implanted with knee arthroplasty components. The knees were flexed dynamically in a weight-bearing rig. Medialization led to lateral shift of the patellar bone, slight medial shift of the patellar component in the femoral groove, lateral tilt of the patella, reduced patellofemoral contact force in later flexion, and lateral shift of the center of pressure in early flexion. Effects on shift and tilt were proportional to the amount of medialization. As a result of this investigation, we recommend medializing the patellar component slightly—on the order of 2.5 mm.  相似文献   

6.
7.

Background

Potential advantages combined with lower cost have prompted a renewed interest in modern all-polyethylene tibial designs.

Methods

A total of 317 Natural Knee total knee arthroplasties with an all-polyethylene tibial component that was performed since 1993 were retrospectively reviewed to confirm that cost savings were not associated with inferior clinical results. They were primarily used in elderly, low-demand patients. The average age at the time of surgery was 80.8 years.

Results

227 knees with a minimum of 2-year follow-up were identified. The average follow-up was 5.6 years (range, 2-20 years). Clinical and radiographic outcomes were evaluated. At the latest follow-up, the average Knee Society and functional score was 94.2 and 57.2. The average postoperative range of motion was 1.6°-115.4°. No patient required a revision for aseptic or septic loosening, wear, or instability. Only 5 knees had a partial nonprogressive cement/bone radiolucency. There was an approximate 33% cost savings for the implants when the all-polyethylene component was used.

Conclusion

An all-polyethylene tibial component of this design provides excellent results in the elderly population along with a significant cost savings.  相似文献   

8.
BackgroundRevision of both femoral and tibial components of a total knee arthroplasty (TKA) for aseptic loosening has favorable outcomes. Revision of only one loose component with retention of others has shorter operative time and lower cost; however, implant survivorship and clinical outcomes of these different operations are unclear.MethodsBetween January 2009 and December 2019, a consecutive cohort of revision TKA was reviewed. Univariate and multivariable analyses were used to study correlations among factors and surgical related complications, time to prosthesis failure, and functional outcomes (University of California Los Angeles, Knee Society functional, knee osteoarthritis and outcome score for joint replacement, Veterans RAND 12 (VR-12) physical, and VR-12 mental).ResultsA total of 238 patients underwent revision TKA for aseptic loosening. The mean follow-up time was 61 months (range 25 to 152). Ten of the 105 patients (9.5%) who underwent full revision (both femoral and tibial components) and 18 of the 133 (13.5%) who underwent isolated revision had subsequent prosthesis failure [Hazard ratio (HR) 0.67, P = .343]. The factor analysis of type of revision (full or isolated revision) did not demonstrate a significant difference between groups in terms of complications, implant failures, and times to failure. Metallosis was related to early time to failure [Hazard ratio 10.11, P < .001] and iliotibial band release was associated with more complications (Odds ratio 9.87, P = .027). Preoperative symptoms of instability were associated with the worst improvement in University of California Los Angeles score. Higher American Society of Anesthesiologists status and higher Charlson Comorbidity Index were related with worse VR-12 physical (?30.5, P = .008) and knee osteoarthritis and outcome score for joint replacement (?4.2, P = .050) scores, respectively.ConclusionIsolated and full component revision TKA for aseptic loosening does not differ with respect to prosthesis failures, complications, and clinical results at 5 years. Poor American Society of Anesthesiologists status, increased comorbidities, instability, and a severe bone defect are related to worse functional improvement.Level of evidenceIII, cohort with control.  相似文献   

9.
BackgroundHigh-viscosity (HV) bone cements have been formulated to offer potentially advantageous handling characteristics. However, alteration in the handling characteristics could influence implant fixation and survival. The primary objective of this study was to use radiostereometric analysis after total knee arthroplasty to assess the migration of the Triathlon tibial component fixed with HV cement (Simplex HV).MethodsTwenty-three patients were followed for two years with radiostereometric analysis examinations at 6 visits. Migration was compared with published thresholds and with a control group from a previously published study from the same center using the same implants fixed with a medium viscosity cement. Inducible displacement was assessed, and Oxford 12 Knee Scores and satisfaction were recorded.ResultsMean maximum total point motion migration reaching 0.40 mm (SD 0.16) at one year, and 0.41mm (SD 0.17) at two years, demonstrating a pattern of stable fixation, below published thresholds of acceptable migration, and not significantly different from the control group. One implant had continuous migration between 1 and 2 years but was clinically asymptomatic. Mean maximum total point motion inducible displacement measured at least one year postoperatively was 0.3 mm (SD 0.12). Mean Oxford 12 Knee Scores improved from 19 (SD 7) preoperatively to 42 (SD 8) 2 years postoperatively.ConclusionsThe use of HV cement demonstrated an acceptable pattern of migration at 2 years, indicating low risk for aseptic loosening.  相似文献   

10.
AIM: To investigate the correlation between preoperative measurement in total knee arthroplasty and the prosthetic size implanted.METHODS: A prospective double-blind study of 50 arthroplasties was performed. Firstly, the reliability and correspondence between the size of said measurement and the actual implant utilized was determined. Secondly, the existing correlation between the intra- and interobserver determinations with the intraclass correlation coefficient was analyzed.RESULTS: An overall correspondence of 54%, improving up to 92% when the measured size admitted a difference of one size, was found. Good intra- and interobserver reliability with an intraclass correlation coefficient greater than 0.90 (P < 0.001) was also discovered.CONCLUSION: Agreement between the preoperative measurement with standardized acetate templates and the prosthetic size implanted can be considered satisfactory. We thus conclude it is a reproducible technique.  相似文献   

11.
12.
13.
14.
15.
Component malrotation is a recognized cause of post total knee arthroplasty (TKA) pain. We reviewed 24 patients who had TKA revision due to component malrotation as the only objective abnormality. Mean combined component rotation was 6.8° excessive internal rotation, as documented by computed tomography. Twenty-four matched control patients had TKA revision due to aseptic loosening. Mean follow-up was 37 months. Preoperative Knee Society Score improved by 49 points at 6 months postoperatively for the malrotation patients and by 39 for the loosening patients. At last follow-up, Knee Society Score was 80 for the malrotation group and 75 for the loosening group. We recommend the use of computed tomography scans in evaluation of all patients with early painful TKAs and no objective evidence of infection. When component malrotation is demonstrated, early revision should be considered.  相似文献   

16.

Background

Preoperative planning is important to achieve successful implantation in primary total knee arthroplasty (TKA). However, traditional TKA templating techniques are not accurate enough to predict the component size to a very close range.

Methods

With the goal of developing a general predictive statistical model using patient demographic information, ordinal logistic regression was applied to build a proportional odds model to predict the tibia component size. The study retrospectively collected the data of 1992 primary Persona Knee System TKA procedures. Of them, 199 procedures were randomly selected as testing data and the rest of the data were randomly partitioned between model training data and model evaluation data with a ratio of 7:3. Different models were trained and evaluated on the training and validation data sets after data exploration.

Results

The final model had patient gender, age, weight, and height as independent variables and predicted the tibia size within 1 size difference 96% of the time on the validation data, 94% of the time on the testing data, and 92% on a prospective cadaver data set.

Conclusion

The study results indicated the statistical model built by ordinal logistic regression can increase the accuracy of tibia sizing information for Persona Knee preoperative templating. This research shows statistical modeling may be used with radiographs to dramatically enhance the templating accuracy, efficiency, and quality. In general, this methodology can be applied to other TKA products when the data are applicable.  相似文献   

17.
目的 随着人工膝关节手术的普及,对修正型人工膝关节的需求也将增加,为此设计了修正型人工膝关节。股骨部件分左、右侧、胫骨部件呈杯状,有中央突起,二者均用于髓内干固定。方法 从1991年7月~1997年12月 5例类风湿性关节炎、2例骨关节炎(3膝)患者修正型人工膝关节置换术。主要手术指征是原人工膝关节已有明显松动,伴有严重疼育或畸形。结果 随访6月~8年。术后所有虱均有,并纠正了原有的力线畸形。5膝  相似文献   

18.
Improved component alignment in TKA remains a commonly cited benefit of MRI based patient-specific instrumentation (PSI). We hypothesized that PSI would lead to improved alignment versus traditional instrumentation (TI) during primary TKA. Fifty-eight knees (54 patients) that underwent TKA with PSI were compared to 62 knees that had previously undergone TKA with TI. Radiographs were evaluated for mechanical axis and alignment of the femoral and tibial components. Alignment was similar between the groups. However, the PSI group showed fewer knees in the target range for posterior tibial slope (PSI 38% vs. TI 61%, P = 0.01) in addition to a trend for fewer knees in target range for femoral flexion (PSI 40% vs. TI 56%, P = 0.07). This study demonstrated no improvement in overall alignment and perhaps a worsening of the tibial slope.  相似文献   

19.
20.
《The Journal of arthroplasty》2019,34(7):1382-1386
BackgroundComponent rotation in total knee arthroplasty is thought to affect patella tracking, flexion gap, and balancing and hence is hypothesized to affect function, pain, and longevity. Few studies have directly correlated post-operative component rotation to function and quality of life in the short to medium term post-operatively, with findings in the current literature conflicting.MethodsA retrospective study of prospectively collected data was used to determine the effect of femoral, tibial, and combined component rotation in primary total knee arthroplasty with primary outcomes being function as measured by the Knee Society Score, pain and quality of life as measured by the Short-Form 12 score, and secondary outcome being prosthesis failure. Malrotation was defined using the current literature as being internally rotated from neutral, or externally rotated greater than 5° for the femoral component, internally rotated greater than 6° for the tibial component, or internally rotated from neutral for the 2 components combined.ResultsNo clinically relevant correlation between function or quality of life and component rotation could be found at 5 years. However, it was noted that those patients with combined component malrotation (femoral rotation added to tibial rotation resulting in overall component internal rotation) improved less in overall pain scores than those that were not malrotated.ConclusionIn the mid-term, component malrotation may result in a decreased level of improvement from pain compared to pre-operative results. However, component malrotation does not make a significant difference to function or quality of life.Level of evidenceLevel III: Therapeutic Study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号