首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

It is well accepted that functional activity of platelet integrin αIIbβ3 is crucial for hemostasis and thrombosis. The β3 subunit of the complex undergoes tyrosine phosphorylation shown to be critical for outside-in integrin signaling and platelet clot retraction ex vivo. However, the role of this important signaling event in other aspects of prothrombotic platelet function is unknown.

Method

Here, we assess the role of β3 tyrosine phosphorylation in platelet function regulation with a knock-in mouse strain, where two β3 cytoplasmic tyrosines are mutated to phenylalanine (DiYF). We employed platelet transfusion technique and intravital microscopy for observing the cellular events involved in specific steps of thrombus growth to investigate in detail the role of β3 tyrosine phosphorylation in arterial thrombosis in vivo.

Results

Upon injury, DiYF mice exhibited delayed arterial occlusion and unstable thrombus formation. The mean thrombus volume in DiYF mice formed on collagen was only 50% of that in WT. This effect was attributed to DiYF platelets but not to other blood cells and endothelium, which also carry these mutations. Transfusion of isolated DiYF but not WT platelets into irradiated WT mice resulted in reversal of the thrombotic phenotype and significantly prolonged blood vessel occlusion times. DiYF platelets exhibited reduced adhesion to collagen under in vitro shear conditions compared to WT platelets. Decreased platelet microparticle release after activation, both in vitro and in vivo, were observed in DiYF mice compared to WT mice.

Conclusion

β3 tyrosine phosphorylation of platelet αIIbβ3 regulates both platelet pro-thrombotic activity and the formation of a stable platelet thrombus, as well as arterial microparticle release.
  相似文献   

2.

Purpose

In vivo imaging of αvβ3 has important diagnostic and therapeutic applications. 18F-Galacto-arginine–glycine–aspartic acid (RGD) has been developed for positron emission tomography (PET) imaging of integrin αvβ3 expression and is now being tested on humans. Dimerization and multimerization of cyclic RGD peptides have been reported to improve the integrin αvβ3-binding affinity due to the polyvalency effect. Here, we compared a number of new dimeric RGD peptide tracers with the clinically used 18F-galacto-RGD.

Procedures

RGD monomers and dimers were coupled with galacto or PEG3 linkers, and labeled with 18F using 4-nitrophenyl 2-18F-fluoropropionate (18F-NFP) or N-succinimidyl 4-18F-fluorobenzoate as a prosthetic group. The newly developed tracers were evaluated by cell-based receptor-binding assay, biodistribution, and small-animal PET studies in a subcutaneous U87MG glioblastoma xenograft model.

Results

Starting with 18F-F?, the total reaction time for 18F-FP-SRGD2 and 18F-FP-PRGD2 is about 120 min. The decay-corrected radiochemical yields for 18F-FP-SRGD2 and 18F-FP-PRGD2 are 52?±?9% and 80?±?7% calculated from 18F-NFP. Noninvasive small-animal PET and direct tissue sampling experiments demonstrated that the dimeric RGD peptides had significantly higher tumor uptake as compared to 18F-galacto-RGD.

Conclusion

Dimeric RGD peptide tracers with relatively high tumor integrin-specific accumulation and favorable in vivo kinetics may have the potential to be translated into clinic for integrin αvβ3 imaging.
  相似文献   

3.

Purpose  

The cell adhesion molecule integrin αvβ3 is an important player in the process of tumor angiogenesis and metastasis. Abegrin™, a fully humanized anti-integrin αvβ3 monoclonal antibody, was currently in clinical trials for cancer therapy. Herein, we labeled Abegrin™ with 111In, evaluated the in vitro and in vivo characteristics, and investigated whether the expression of integrin αvβ3 in tumors could be imaged with 111In-labeled Abegrin™.  相似文献   

4.

Purpose

Increased expression of the αvβ6 integrin correlates with advanced tumor grade and poor clinical outcome, identifying αvβ6 as a prognostic indicator and an attractive target for molecular imaging. This work investigated the ability of a disulfide-stabilized [64Cu]NOTA-αvβ6 cys-diabody to image αvβ6 expression in vivo using a nu/nu mouse model bearing human melanoma xenografts and positron-emission tomography.

Procedures

Small-animal positron emission tomography (PET) imaging, quantitative ROI analysis, and ex vivo biodistribution were conducted to ascertain tumor uptake and organ distribution of the [64Cu]NOTA-αvβ6 cys-diabody. Immunohistochemical staining of tumors and mouse organs and immunoreactivity assays were utilized to correlate in vivo and ex vivo observations.

Results

PET imaging of the [64Cu]NOTA-αvβ6 cys-diabody revealed low tumor uptake at 24 h p.i. in DX3Puroβ6 tumors (2.69 ± 0.45 %ID/g) with comparable results found in the DX3Puro tumors (2.24 ± 0.15 %ID/g). Quantitative biodistribution confirmed that DX3Puroβ6 tumor uptake was highest at 24 h p.i. (4.63 ± 0.18 %ID/g); however, uptake was also observed in the stomach (4.84 ± 2.99 %ID/g), small intestines (4.50 ± 1.69 %ID/g), large intestines (4.73 ± 0.97 %ID/g), gallbladder (6.04 ± 1.88 %ID/g), and lungs (3.89 ± 0.69 %ID/g).

Conclusions

Small-animal PET imaging was successful in visualizing αvβ6-positive tumor uptake of the [64Cu]NOTA-αvβ6 cys-diabody. Cys-diabody cross-reactivity was observed between human and murine αvβ6 and immunohistochemical staining confirmed the presence of an endogenous αvβ6 antigen sink, which led to suboptimal tumor contrast in this mouse model. Future investigations will focus on dose escalation studies to overcome the endogenous antigen sink while increasing DX3Puroβ6 tumor uptake.
  相似文献   

5.

Purpose

Molecular imaging of αvβ3 integrin has exhibited real potential to guide the appropriate use of anti-angiogenic therapies. However, an incomplete understanding of the factors that influence binding of αvβ3 integrin-specific radiotracers currently limits their use for assessing response to therapy in cancer patients. This study identifies two fundamental factors that modulate uptake of these radiotracers.ProceduresExperiments were performed in prostate cancer (PC3) and glioblastoma (U87MG) cells, which differentially express αvβ3 integrin. αvβ3 integrin-specific radiotracers were used to investigate the effect of manipulating αvβ3 integrin expression or activation in cellular binding assays. β3 integrin and αvβ3 integrin expression were measured by western blotting and flow cytometry, respectively. The effect of select pharmacological inhibitors on αvβ3 integrin activation and expression was also determined.

Results

Radiotracer binding was proportional to αvβ3 integrin expression when it was decreased (β3 knock-down cells) or increased, either using pharmacological inhibitors of cell signalling or by culturing cells for different times. Studies with both small molecule and arginine–glycine–aspartic acid (RGD)-based radiotracers revealed increased radiotracer binding after activation of αvβ3 integrin with Mn2+ or talin head domain. Moreover, inhibition of fundamental signalling pathways (mitogen-activated protein kinase kinase (MEK), Src and VEGFR2) decreased radiotracer binding, reflecting reduced αvβ3 integrin activity.

Conclusion

Binding of small molecule ligands and radiolabelled RGD peptides is modulated by expression and activation status of αvβ3 integrin. αvβ3 integrin-specific radiotracers can provide otherwise inaccessible information of the effect of signalling pathways on αvβ3 integrin. This has significant implications for assessing response to anti-angiogenic therapies in clinical studies.
  相似文献   

6.

Purpose

To compare targeted imaging of vascular endothelial growth factor (VEGF) receptors vs. αvβ3 integrins in a mouse hindlimb ischemia model of peripheral artery disease.

Procedures

Male wild-type (WT) C57BL/6 mice (8- to 10-week old) (n?=?24) underwent left femoral artery ligation. The right leg served as control. Five days later, mice were injected with either VEGF receptor targeting [99mTc]DOTA-PEG-scVEGF ([99mTc]scV) (n?=?8) or with αvβ3-targeting tracer [99mTc]HYNIC-cycloRGD ([99mTc]RGD) (n?=?8) and underwent single photon emission computed tomography (SPECT) x-ray computed tomography imaging. To assess non-specific [99mTc]scV uptake, six additional mice received a mixture of [99mTc]scV and 30-fold excess of targeting protein, scVEGF. Tracer uptake as %ID was measured using volumetric regions encompassing the hindlimb muscles and as %ID/g from harvested limb muscles. Double and triple immunofluorescent analysis on tissue sections established localization of αvβ3, VEGFR-1, VEGFR-2, as well as certain cell lineage markers.

Results

Tracer uptake, as %ID/g, was higher in ligated limbs of mice injected with [99mTc]scV compared to ligated hindlimbs in mice injected with [99mTc]RGD (p?=?0.02). The ratio of tracer uptake for ligated/control hindlimb was borderline higher for [99mTc]scV than for [99mTc]RGD (p?=?0.06). Immunofluorescent analysis showed higher prevalence of VEGFR-1, VEGFR-2, and αvβ3, in damaged vs. undamaged hindlimb tissue, but with little co-localization of these markers. Double immunofluorescent staining showed partial co-localization of VEGFR-1, VEGFR-2, and αvβ3, with endothelial cell marker FVIII, but not with CD31. Immunostaining for VEGFR-1 and VEGFR-2 additionally co-localized with lineage markers for endothelial progenitor cell and monocytes/macrophages, with a more diverse pattern of co-localization for VEGFR-2.

Conclusion

In a mouse hindlimb ischemia model of peripheral artery disease, [99mTc]scV SPECT tracer-targeting VEGF receptors showed a more robust signal than [99mTc]RGD tracer-targeting αvβ3. Immunofluorescent analysis suggests that uptake of [99mTc]scV and [99mTc]RGD in damaged tissue is due to non-overlapping cell populations and reflects different dynamic processes and that enhanced uptake of [99mTc]scV may be due to the presence of VEGF receptors on additional cell types.
  相似文献   

7.

Purpose  

99mTc-3PRGD2 is a 99mTc-labeled dimeric cyclic RGD peptide with increased receptor binding affinity and improved kinetics for in vivo imaging of integrin αvβ3 expression in nude mouse model. To accelerate its clinical translation, we reported here the evaluation of the kit-formulated 99mTc-3PRGD2 in healthy cynomolgus primates for its blood clearance kinetics, biodistribution, and radiation dosimetry.  相似文献   

8.

Purpose

This study aimed to investigate the value of 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid ([99mTc]3PRGD2) imaging in diagnosis and staging of breast cancer compared with 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) imaging, and to explore the expression of integrin αvβ3 in tumor vascular endothelial cells.

Procedures

Forty-two women with suspected breast cancer underwent both [99mTc]3PRGD2 imaging and [18F]FDG imaging. Visual analysis was used to assess primary breast lesion, axillary lymph node, and distant metastasis. The tumor-blood (T/B) ratios from [99mTc]3PRGD2 imaging and the maximum standardized uptake value (SUVmax) from [18F]FDG imaging were analyzed for breast lesions. Integrin αvβ3 was analyzed through immunohistochemistry.

Results

Forty-five breast lesions were found (malignant, n?=?38; benign, n?=?7). The sensitivity, specificity, and accuracy of [99mTc]3PRGD2 and [18F]FDG imaging in visual analysis for the breast lesion were 97.4, 87.5, and 95.6 % and 97.4, 71.4, and 93.3 %, respectively (P?>?0.05). For semi-quantitative analysis, no significant difference of the area under the curves (AUC) was found in the imaging using the two radiopharmaceuticals (0.880 and 0.955; Z?=?0.88, P?>?0.05). The sensitivity, specificity, and accuracy for axillary lymph node metastasis with [99mTc]3PRGD2 and [18F]FDG were 78.05, 99.36, and 94.92 % and 85.37, 98.72, and 95.64 %, respectively (P?>?0.05). Nine patients with distant metastases were all detected with the two radiopharmaceuticals. The expression of integrin αvβ3 was correlated with [99mTc]3PRGD2 uptake (r?=?0.582, P?=?0.001), which were significantly higher in the HER2-positive and stage III–IV patients (P?<?0.05).

Conclusions

The prospective study demonstrated that [99mTc]3PRGD2 imaging seems to be valuable for diagnosis of breast cancer and its staging. It may be less sensitive for detecting small lymph node metastatic lesions when compared with [18F]FDG imaging. Integrin αvβ3 in tumor microvessels was associated with the breast cancer subtype and its staging.
  相似文献   

9.
10.
Low flow anesthesia increases the use of CO2 absorbents, but independent data that compare canister life of the newest CO2 absorbents are scarce. Seven different pre-packed CO2 canisters were tested in vitro: Amsorb Plus, Spherasorb, LoFloSorb, Medisorb, Medisorb EF, LithoLyme, and SpiraLith. CO2 (160 mL min?1) flowed into the tip of a 2 L breathing bag that was ventilated with a tidal volume of 500 mL, a respiratory rate of 10/min, and an I:E ratio of 1:1 using the controlled mechanical ventilation mode of the Aisys ® (GE, Madison, WI, USA). In part I, canister life of each brand (all of the same lot) was tested with 12 different fresh gas flows (FGF) ranging from 0.25 to 4 L min?1. In part II, canister life of six canisters each of two different lots of each brand were tested with a 350 mL min?1 FGF. Canister life is presented as “FCU”, fractional canister usage, the fraction of a canister used per hour, and is defined for the inspired CO2 concentration (FICO2) that denotes exhaustion. In part III, canister life per 100 g fresh granule content was calculated. FCU decreased linearly with increasing FGF. The relative position of the FCU–FGF curves of the different brands depends on the FICO2 threshold because the exhaustion rate (the rate of rise once FICO2 starts to increase) differs among the brands. Intra-lot variability was 18 % or less. The different prepacks can be ranked according their efficiency (least to most efficient) as follows: Amsorb Plus = Medisorb EF < LoFloSorb < Medisorb = Spherasorb = LithoLyme < SpiraLith (all for an FICO2 threshold = 0.5 %). Canister life per 100 g fresh granule content is almost twice as long when LiOH is used as the primary absorbent. The most important factors that determine canister life of prepacks in a circle breathing system are the chemical composition of the canister, the absolute amount of absorbent present in the canister, and the FICO2 replacement threshold. The use of the fractional canister usage allows cost comparisons among different prepacks. Results should not be extrapolated to prepacks that fit onto other anesthesia machines.  相似文献   

11.
Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. Pre-packed CO2 canisters of 8 different brands were tested in vitro: Amsorb Plus, Spherasorb, LoFloSorb, LithoLyme, SpiraLith, SpheraSorb, Drägersorb 800+, Drägersorb Free, and CO2ntrol. CO2 (160 mL min??1) flowed into the tip of a 2 L breathing bag that was ventilated with a tidal volume of 500 mL, a respiratory rate of 10/min, and an I:E ratio of 1:1 using the controlled mechanical ventilation mode of the Zeus® (Dräger, Lubeck, Germany). In part I, canister life of 5 canisters each of 2 different lots of each brand was determined with a 350 mL min??1 FGF. Canister life is the time it takes for the inspired CO2 concentration (FICO2) to rise to 0.5%. In part II, canister life was measured accross a FGF range of 0.25 to 4 L min??1 for Drägersorb 800+ (2 lots) and SpiraLith (1 lot). In part III, the calculated canister life per 100 g fresh granule content of the different brands was compared between the Zeus and (previously published data for) the Aisys. In vitro canister life of prefilled CO2 absorber canisters differed between brands, and depended on the amount of CO2 absorbent and chemical composition. Canister life expressed as FCU0.5 (the fraction of the canister used per hour) was proportional to FGF over 0.2–2 L min?1 range only, but was non-linear with higher FGF: FCU0.5 was larger than expected with FGF?>?2 L min?1, and even with FGF?>?minute ventilation FCU0.5 did not become zero, indicating some CO2 was being absorbed. Canister life on a per weight basis of the same brand is higher with the Zeus than the Aisys. Canister life of prefilled CO2 absorber canisters differs between brands. The FCU0.5–FGF relationship is not linear across the entire FGF range. Canister life of prepacks of the same brand for the Zeus and Aisys differs, the exact etiology of which is probably multifactorial, and may include differences in the absolute amount of absorbent and different rebreathing characteristics of the machines.  相似文献   

12.
Physicians often need to measure arterial PCO2 in clinical practice. Arterial blood gas sampling is typically available only in hospitals and may be unpleasant for patients. Minimally invasive techniques for measuring PCO2 offer the potential for overcoming these limitations. The MicroStat monitor non-invasively measures PCO2 in the sublingual tissues, which should track arterial PCO2 in hemodynamically stable patients. This was a prospective observational study. Patients undergoing routine cardiac catheterization were recruited. Following arterial cannulation, two sequential sublingual PCO2 measurements were taken and a contemporaneous arterial sample was sent for blood gas analysis. For each subject we calculated the mean sublingual–arterial CO2 gradient and the test–retest sublingual PCO2 difference. Twenty-five patients were studied. Mean sublingual–arterial PCO2 gradient was +6.8 mmHg (95 % limits of agreement ?3.0 to 16.6 mmHg). Test–retest difference was 3.4 mmHg (95 % limits of agreement ?1.1 to 7.9 mmHg), p = 0.11 (Wilcoxon test), repeatability was 11 mmHg. The MicroStat sublingual PCO2 monitor over-estimates arterial PCO2 with wide limits of agreement. Test–retest repeatability was poor. Use of sublingual PCO2 monitoring with the MicroStat monitor cannot currently replace blood gas sampling.  相似文献   

13.

Purpose  

We assessed test–retest variability of cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO2), and oxygen extraction fraction (OEF) measurements derived from dynamic 15O positron emission tomography (PET) scans.  相似文献   

14.

Background  

The β1-adrenoceptor (β1AR) mediates cardiostimulatory effects of catecholamines in the heart. The Arg389Gly polymorphism of the β1AR gene has recently been shown to determine the responsiveness to catecholamines in vitro, and we previously reported that dobutamine induced an augmented contractile response in humans homozygous for the Arg389 allele. The aim of the present study was to evaluate whether the Arg389Gly β1AR gene polymorphism influences the responsiveness to β-blocker treatment on cardiac contractility.  相似文献   

15.
16.

Introduction  

Epidermal growth factor receptor (EGFR)-targeted therapies with antibodies and small molecular EGFR kinase inhibitors have shown poor efficacy in unselected populations of patients with advanced non-small cell lung carcinomas (NSCLC). In contrast, patients with overexpression of EGFR and activating mutations in EGFR kinase domain demonstrated improved responses to EGFR kinase inhibitors. Therefore, we have developed a novel radiotracer, [18F]F-PEG6-IPQA for PET imaging of EGFR expression-activity in NSCLC, and have described its radiosynthesis and in vitro evaluation in two NSCLC cell lines with wild-type and L858R active mutant EGFR.  相似文献   

17.

Purpose  

Hyperoxia may induce pulmonary injury and may increase oxidative stress. In this retrospective database study we aimed to evaluate the response to hyperoxia by intensivists in a Dutch academic intensive care unit.  相似文献   

18.
PURPOSE: [carbonyl-11C]N-(2-(1-(4-(2-methoxyphenyl)-piperazinyl)ethyl)-N-pyridinyl)cyclohexanecarboxamide ([carbonyl-11C]WAY-100635) is an effective radioligand for imaging brain 5-HT1A receptors with positron emission tomography (PET). However, this radioligand has some drawbacks for deriving relative regional receptor densities, including rapid metabolism, which acts against accurate definition of an arterial input function for compartmental modeling, and very low nonspecific binding in brain, which detracts from the accuracy of modeling by a simplified reference tissue (cerebellum) approach. Here, in a search for a radioligand that overcomes these limitations, we investigated the effects of introducing a single methyl group at either of the carbon atoms alpha to the amide bond in [11C]WAY-100635. PROCEDURES: Ligands with a methyl group on the alpha carbon of the cyclohexyl group (SWAY) or the alpha carbon of the C2H4 linker ((R,S)-JWAY) were synthesized and tested for binding affinity and intrinsic activity at 5-HT1A receptors. SWAY was labeled with carbon-11 (t1/2 = 20.4 minutes; beta+ = 99.8%) in its O-methyl group and (R,S)-JWAY in its carbonyl group. Each radioligand was evaluated by PET experiments in cynomolgus monkey. RESULTS: SWAY and (R,S)-JWAY were found to be high-affinity antagonists at 5-HT1A receptors. After injection of [11C]SWAY into monkey, radioactivity uptake in brain reached a maximum of 3% at 4.5 minutes and decreased to 0.7% at 72 minutes. However, over the time span of the experiment, radioactivity concentrations in 5-HT1A receptor-rich brain regions were only fractionally higher than in cerebellum. Radioactivity represented by parent radioligand in plasma was 39% at 45 minutes. After injection of [11C](R,S)-JWAY alone, radioactivity uptake in brain reached a maximum of 4.8% at 2.5 minutes and decreased to 1.2% at 90 minutes. At this time, radioactivity concentration in 5-HT1A receptor-rich brain regions was markedly greater than in cerebellum. In another PET experiment, the monkey was predosed with WAY-100635 before [11C](R,S)-JWAY injection. At 90 minutes after injection, the ratio of radioactivity in 5-HT1A receptor-rich regions to that in cerebellum was reduced to near unity. Radioactivity represented by parent radioligand in plasma was 12% at 45 minutes. CONCLUSIONS: [11C](R,S)-JWAY, but not [11C]SWAY, gives a sizeable 5-HT1A receptor-selective PET signal in monkey. The presence of a C-methyl group adjacent to the amide bond in SWAY or (R,S)-JWAY fails to counter metabolism.  相似文献   

19.
The venous–arterial difference in CO2 (ΔCO2) has been proposed as an index of the adequacy of tissue perfusion in shock states. We hypothesized that the variation in PaCO2 (hyper- or hypocapnia) could impact ΔCO2, partly through microcirculation adaptations. Fifteen healthy males volunteered to participate. For hypocapnia condition (hCO2), the subjects were asked to hyperventilate, while they were asked to breathe a gas mixture containing 8 % CO2 for hypercapnia condition (HCO2). The 2 conditions were randomly assigned. Blood gases were measured at baseline before each condition, and after 5–7 min of either hCO2 or HCO2 condition. Microcirculation was assessed by the muscle reoxygenation slope measured with near infrared spectroscopy following a vascular occlusion test and by skin circulation with in vivo reflectance confocal microscopy. ΔCO2 was significantly increased with hCO2 while it tended to decrease with HCO2 (non-significant). HCO2 induced a moderate increase of the resaturation slope of NIRS oxygenation. Skin microcirculatory blood flow significantly dropped with hCO2, while it remained unchanged with hypercapnia. Our results warrant cautious interpretation of ΔCO2 as an indicator of tissue perfusion during respiratory alkalosis.  相似文献   

20.
Alterations in arterial blood oxygen saturation, heart rate (HR), and respiratory rate (RR) are strongly associated with intra-hospital cardiac arrests and resuscitations. A wireless, easy-to-use, and comfortable method for monitoring these important clinical signs would be highly useful. We investigated whether the Nellcor? OxiMask MAX-FAST forehead sensor could provide data for vital sign measurements when located at the distal forearm instead of its intended location at the forehead to provide improved comfortability and easy placement. In a prospective setting, we recruited 30 patients undergoing surgery requiring postoperative care. At the postoperative care unit, patients were monitored for two hours using a standard patient monitor and with a study device equipped with a Nellcor? Forehead SpO2 sensor. The readings were electronically recorded and compared in post hoc analysis using Bland–Altman plots, Spearman’s correlation, and root-mean-square error (RMSE). Bland–Altman plot showed that saturation (SpO2) differed by a mean of ?0.2 % points (SD, 4.6), with a patient-weighted Spearman’s correlation (r) of 0.142, and an RMSE of 4.2 points. For HR measurements, the mean difference was 0.6 bpm (SD, 2.5), r = 0.997, and RMSE = 1.8. For RR, the mean difference was ?0.5 1/min (4.1), r = 0.586, and RMSE = 4.0. The SpO2 readings showed a low mean difference, but also a low correlation and high RMSE, indicating that the Nellcor? saturation sensor cannot reliably assess oxygen saturation at the forearm when compared to finger PPG measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号