首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A case of a 51-year old male is presented. A left bundle branch block inferior axis tachycardia was manifest. At electrophysiological study this tachycardia was inducible and was ablated in the septal right ventricular outflow tract (RVOT). Two other tachycardias were identified both with right bundle branch block (RBBB) morphology raising the suspicion of diffuse pathology. Arrythmogenic right ventricular dysplasia (ARVD) was confirmed by right ventricular angiography and magnetic resonance imaging (MRI). An implantable cardioverter defibrillator (ICD) was implanted and an appropriate shock was later delivered.  相似文献   

2.
Cryocatheter ablation of right ventricular outflow tract tachycardia   总被引:1,自引:0,他引:1  
INTRODUCTION: Cryocatheter techniques have been successfully applied to treat supraventricular tachycardia but there are no reports on their value in treating ventricular tachycardia (VT). We present our initial experience with cryocatheter ablation of right ventricular outflow tract (RVOT) tachycardia. METHODS AND RESULTS: Cryocatheter ablation was attempted in 14 patients (13 females, age 45.9 +/- 12.7 years) who were highly symptomatic due to frequent monomorphic ventricular extrasystole (VES) or nonsustained VT originating within the RVOT. A 9-Fr, 8-mm-tip cryocatheter was used for both mapping and ablation. Cryoablation was started after localizing the arrhythmic focus by pace and activation mapping. Ablation success, defined by complete disappearance of target VES/VT acutely and during a follow-up of 9.3 +/- 1.4 weeks, was achieved in 13 of 14 patients. Ablation was successful with local activation times of 35 +/- 4 ms, 5.8 +/- 3.3 applications, 18.8 +/- 7.5 minutes total cryo time, 9.4 +/- 4.2 minutes fluoroscopy time, and 66.9 +/- 26.1 minutes total procedure time, the latter two measures showing a reduction with number of patients treated. Three patients reported slight pain related to local pressure of the catheter on the RVOT wall. No pain was described related to delivery of cryothermal energy. CONCLUSIONS: Initial experience shows that focal VES/VT originating in the RVOT can be successfully treated using cryocatheter ablation. Acute and short term success rates, fluoroscopy times, and duration of procedure are comparable to conventional ablation techniques. A major advantage seems to be the virtual absence of ablation related pain.  相似文献   

3.
INTRODUCTION: Activation mapping and pace mapping identify successful ablation sites for catheter ablation of right ventricular outflow tract (RVOT) tachycardia. These methods are limited in patients with nonsustained tachycardia or isolated ventricular ectopic beats. We investigated the feasibility of using noncontact mapping to guide the ablation of RVOT arrhythmias. METHODS AND RESULTS: Nine patients with RVOT tachycardia and three patients with ectopic beats were studied using noncontact mapping. A multielectrode array catheter was introduced into the RVOT and tachycardia was analyzed using a virtual geometry. The earliest endocardial activation estimated by virtual electrograms was displayed on an isopotential color map and measured 33 +/- 13 msec before onset of QRS. Virtual unipolar electrograms at this site demonstrated QS morphology. Guided by a locator signal, ablation was performed with a mean of 6.9 +/- 2.2 radiofrequency deliveries. Acute success was achieved in all patients. During follow-up, one patient had a recurrence of RVOT tachycardia. Compared with patients (n = 21) who underwent catheter ablation using a conventional approach, a higher success rate was achieved by noncontact mapping. Procedure time was significantly longer in the noncontact mapping group. Fluoroscopy time was not significantly different in the two groups. CONCLUSION: Noncontact mapping can be used as a reliable tool to identify the site of earliest endocardial activation and to guide the ablation procedure in patients with RVOT tachycardia and in patients with ectopic beats originating from the RVOT.  相似文献   

4.

1 Introduction

Various ECG algorithms have been proposed to identify the origin of idiopathic outflow tract (OT)‐ventricular arrhythmia (VA). However, electrocardiographic features of failed and recurrent right ventricular outflow tract (RVOT) ablation of idiopathic OT‐VAs have not been clearly elucidated.

2 Methods and results

A total of 264 consecutive patients (mean age: 44.0 ± 13.0 years, 96 male) undergoing RVOT ablation for OT‐VAs with a transition ≥V3, including 241 patients (91.6%) with initially successful procedures and 23 patients (8.4%) with failed ablation. Detailed clinical characteristics and ECG features were analyzed and compared between the two groups. VAs with failed RVOT ablation had larger peak deflection index (PDI), longer V2 R wave duration (V2Rd), smaller V2 S wave amplitude, higher R/S ratio in V2, higher V3 R wave amplitude, and larger V2 transition ratio than those with successful ablation. Multivariate analysis demonstrated that PDI, V2Rd, V2 transition ratio, and pacemapping score acquired during mapping independently predicted failed ablation (P  =  0.01, P  =  0.01, P  =  0.01, and P < 0.001, respectively). In 31 recurrent cases (12.8%) after initially successful ablation, multivariate Cox regression analysis showed that only the earliest activation time acquired during mapping predicted the recurrences after successful ablation (P  =  0.001). The recurrent cases displayed different ECG features comparing with those with failed ablation.

3 Conclusion

The electrocardiographic features of failed RVOT ablation of idiopathic OT‐VAs with a transition ≥V3 were characterized by PDI, V2Rd, V2 transition ratio, and pacemapping score acquired during mapping, unlike the recurrent RVOT ablation.  相似文献   

5.
Background: Despite similar QRS morphology, idiopathic repetitive monomorphic ventricular tachyarrhythmias (VTs) of left ventricular outflow tract (LVOT) are known to have the variants of different adjacent origins, including the aorto-mitral continuity (AMC), anterior site around the mitral annulus (MA), aortic sinus cusps (ASC), and epicardium. However, the electrocardiographic characteristics of those variants previously have not been evaluated fully.
Methods and Results: Based on the mapping site and successful ablation in 45 consecutive patients with LVOT-VTs, we classified them into VTs of AMC (n = 3), MA (n = 8), ASC (n = 32), and epicardial (n = 2) origins. In all patients, we performed activation mapping and an electrocardiographic analysis. All AMC-VTs patients had monophasic R waves in almost all the precordial leads, while those with anterior MA-VTs had an Rs pattern in some precordial leads except for lead V6, and those with ASC-VTs had a variable transitional zone in leads V1–4. There was no S wave in lead V6 in any group except for one patient with anterior MA-VTs. The intrinsicoid deflection time in the AMC-VTs patients and anterior MA-VTs patients was significantly greater than in those with ASC-VTs (P < 0.05). There was no significant difference in the R-wave amplitude in the inferior leads among the groups. Successful radiofrequency catheter ablation (RFCA) was achieved in all patients except for in those with epicardial origin VT.
Conclusions: Despite many morphological similarities, the LVOT-VTs originating from the AMC, anterior MA and ASC could be identified by our proposed electrocardiographic characteristics in order to safely perform RFCA.  相似文献   

6.
INTRODUCTION: Thermal damage to coronary arteries during catheter ablation has been previously reported. Coronary artery damage during LV outflow tract ventricular tachycardia is well recognized. However, the relationship of the coronary arteries to the RV outflow tract during catheter ablation has not been delineated. The purpose of this study was to define the relationship between the RV outflow tract and the coronary arteries utilizing arteriography, echocardiography, CT angiography, and gross anatomic pathology. METHODS: The relationship of the coronaries to the RV outflow tract was analyzed in three patients groups: Group 1: patients (n = 10) undergoing RV outflow tract ventricular tachycardia; Group 2: patients (n = 50) undergoing CT coronary angiography; Group 3: patients (n = 4) undergoing echocardiography during open heart surgery and intracardiac echocardiography (ICE) during catheter ablation of atrial fibrillation (n = 5). RESULTS: Group 1: The left main coronary artery was found to be 3.8 +/- 1.2 mm from the right ventricular outflow tract in patients undergoing ablation. Group 2: The minimum distance between the left main, left anterior descending, and right coronary artery to the RV outflow tract endocardial wall were 4.1 +/- 1.9 mm, 2.0 +/- 0.6 mm, and 4.3 +/- 1.9 mm (average +/- SD) respectively. Group 3: During open heart surgery using echocardiography, the minimum distance between the left main and the right coronary artery to the RV outflow tract were 3.4 +/- 0.35 mm and 2.0 +/- 0.1 mm, respectively. The distance between the let main coronary artery and the RVOT by ICE was 3.8 +/- 0.45 mm. CONCLUSIONS: The major coronary arteries lie in close proximity of the RVOT, and their anatomic course should be taken into consideration during ablation of ventricular tachycardias arising from the RV outflow tract.  相似文献   

7.
目的 探讨特发性左心室流出道室性心动过速(室速)心电图特点及射频导管消融结果。方法 对5例未发现器质性心脏病的左心室流出道室速患者行12导联心电图、动态心电图、心内电生理检查及射频导管消融治疗。结果5例患者心电图Ⅱ、Ⅲ、aVF导联呈R波;Ⅰ导联呈rs或QS波,振幅大于0.5mV;V1导联呈rs或RS波,胸前导联R波移行发生于V2~V3;aVR和aVL导联呈QS波,3例患者的消融靶点在左冠状窦口内,2例位于主动脉瓣下,随访6个月,无1例复发。结论 左心室流出道室速有特殊心电图表现,射频导管消融是首选的治疗措施。  相似文献   

8.
9.
Coronary artery injury is a rare complication of catheter ablation in the right ventricular outflow tract (RVOT). Furthermore, acute myocardial ischemia usually causes polymorphic ventricular tachycardia (VT) or ventricular fibrillation. We herein describe a case in which catheter ablation for VT originating from the RVOT provoked ischemia-related VTs due to acute occlusion of the left anterior descending artery.  相似文献   

10.
11.
12.
BACKGROUND: The purpose of this study was to compare the spatial resolution of activation mapping and pacemapping in patients undergoing ablation of idiopathic ventricular tachycardia (VT) arising from the right ventricular outflow tract (RVOT). A direct comparison of the two techniques has not been undertaken. METHODS AND RESULTS: Electroanatomical activation maps of the RVOT were obtained during VT in 15 patients. Pacemaps were obtained from multiple sites, tagged on the activation map, and scored according the degree of concordance between the paced QRS configuration and that of VT. The site of successful ablation was considered the VT site of origin. Initial endocardial activation away from the site of origin was rapid; the mean area of myocardium activated within the first 10 msec (early activation area, EAA) was 3.0 +/- 1.6 cm(2) (range: 1.3-6.4 cm(2)). Best pacemap scores were always obtained adjacent to the site of origin. Pacemap concordance, and the probability of an exact pacemap match significantly decreased with increasing distance of the pacing site from the site of origin (P < 0.01). All patients had more than one pacing site yielding a best pacemap score. The greatest distance between such sites in an individual patient ranged from 11 to 26 mm (mean: 18 +/- 5 mm), and was strongly correlated with the size of the EAA (r = 0.77, P < 0.001). CONCLUSIONS: Pacemapping and activation mapping provide similar localizing information. The spatial resolution of each technique is modest, varies between patients, and may be optimized by three-dimensional data display.  相似文献   

13.
INTRODUCTION: Most idiopathic nonreentrant ventricular tachycardia (VT) and ventricular premature contractions (VPCs) arise from the right or left ventricular outflow tract (OT). However, some right ventricular (RV) VT/VPCs originate near the His-bundle region. The aim of this study was to investigate ECG characteristics of VT/VPCs originating near the His-bundle in comparison with right ventricular outflow tract (RVOT)-VT/VPCs. METHODS AND RESULTS: Ninety RV-VT/VPC patients underwent catheter mapping and radiofrequency ablation. ECG variables were compared between VT/VPCs originating from the RVOT and near the His-bundle. Ten patients had foci near the His-bundle (HIS group), with the His-bundle local ventricular electrogram preceding the QRS onset by 15-35 msec (mean: 22 msec) and His-bundle pacing produced a nearly identical ECG to clinical VT/VPCs. The HIS group R wave amplitude in the inferior leads (lead III: 1.0 +/- 0.6 mV) was significantly lower than that of the RVOT group (1.7 +/- 0.4 mV, P < 0.05). An R wave in aVL was present in 6 of 10 HIS group patients, while almost all RVOT group patients had a QS pattern in aVL. Lead I in HIS group exhibited significantly taller R wave amplitudes than RVOT group. HIS group QRS duration in the inferior leads was shorter than that of the RVOT group. Eight of 10 HIS group patients exhibited a QS pattern in lead V1 compared to 14 of 81 RVOT group patients. HIS group had larger R wave amplitudes in leads V5 and V6 than RVOT group. CONCLUSION: VT/VPCs originating near the His-bundle have distinctive ECG characteristics. Knowledge of the characteristic QRS morphology may facilitate catheter mapping and successful ablation.  相似文献   

14.
We describe a patient with polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) without organic heart disease who was cured by radiofrequency catheter ablation. The patient was a 65-year-old woman with a 10-year history of recurrent syncope. There was no evidence of organic heart disease, and the QT interval during sinus rhythm was borderline normal (corrected QT interval = 0.45 sec1/2). ECG recording during syncope showed PVT. On one occasion, PVT degenerated into VF. This PVT was always induced by a premature ventricular complex (PVC) originating from the right ventricular (RV) outflow tract. Rapid pacing (220 beats/min) at the site of PVC origin reproduced polymorphic change of the QRS wave on surface ECG that was similar to PVT. This suggests that the PVT originated from a single focus in the RV outflow tract. Catheter ablation was performed at the site of PVC origin. During 18-month follow-up, PVT/VF was not documented.  相似文献   

15.
This study reports new electrocardiographic (ECG) predictors of radiofrequency catheter ablation failure and recurrence in idiopathic right ventricular outflow tract (RVOT) ventricular tachycardia (VT) or ectopy based on 91 consecutive patients. Procedural success and failure rates were 85% (77/91) and 15% (14/91), respectively. Twenty three percent (18/77) had recurrence during the follow-up period of 1 to 120 months (mean 56 +/- 31 months). Baseline RVOT VT/ectopy on 12-lead ECG taken prior to ablation from 91 patients were retrospectively analyzed. Ablation performed with RVOT ectopy (isolated ectopies, bigeminy, trigeminy, or couplets) as template arrhythmia was more likely to fail (30% vs. 8%, P =.02) as opposed to RVOT VT (sustained or nonsustained). VT/ectopy-QRS morphology variation was more observed in failed ablations (36% vs. 7%, P =.001). Significantly wider mean VT/ectopy QRS in leads I, II, AVR, V2, V3, V5, and V6 were noted in failed ablation group. Mean R wave amplitude reached statistical significance only in lead II (22.0 +/- 5.1 mV for failed vs. 17.8 +/- 5.2 mV for successful outcomes; P =.009). QRS morphologic variation (47% vs. 16%; P =.009) was the only statistically significant ECG to be more common in patients with arrhythmia recurrence. In conclusion, ablation with ectopy over VT as template arrhythmia, presence of QRS morphologic variation, wider mean QRS width, and taller mean R-wave amplitude in lead II were identified ECG predictors of failed RVOT VT/Ectopy ablation. The only ECG predictor of recurrence was the presence of RVOT VT or ectopy QRS morphologic variation.  相似文献   

16.
目的 起源于右心室流出道(RVOT)不同位点的室性心动过速(VT)具有相应的心电图表现,本研究旨在摸索一种相对简单的根据体表心电图进行定位的方法 .方法 将RVOT分为游离壁和间隔而两大区,其中间隔面又分为9个区域.共320例RVOT-VT患者中,对213例既往消融成功患者的靶点与体表12导联心电图中QRS波形态之间的关系进行分析,并在消融前前瞻性地对另外107例患者的消融靶点进行预测,以检验其定位价值.结果 I导联对RVOT起源的VT有特殊的定位价值.在间隔面前部起源时,I导联以负向波为主,多为QS、Qr及rS型,随着起源点从前向后、从上向下,R波逐渐升高,其中起源于间隔侧中带(2、5、8区)时,以"M"型居多,在后壁时则表现为R波且有切迹.游离壁起源者的QRS时限明显延长,I和aVL导联的R波较间隔起源者高,而下壁导联的R波均较间隔的低(P<0.05).在前瞻性分析中,这些参数的敏感度、特异度、阳性和阴性预测值均较高.结论 RV-OT不同部位起源的VT有相应的心电图特征,其中I导联形态尤其具有定位价值,为RVOT心律失常起源提供了简便的定位标准.  相似文献   

17.
BACKGROUND: Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. OBJECTIVE: The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. METHODS: In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. RESULTS: The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. CONCLUSION: The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.  相似文献   

18.
目的报道4例特发性右室流出道(RVOT)室性早搏(PVC)触发多形性室性心动过速/心室颤动(PVT/VF)的临床特点。方法 76例起源于RVOT的VT患者,其中4例为PVC触发PVT/VF,总结4例的临床资料并与另72例有关资料相比较。结果所有4例触发PVT/VF时的PVC与孤立PVC的形态一致,但2种PVC的联律间期发生了明显改变,其改变幅度均≥70 ms,其中2例缩短,2例延长。1例孤立PVC时的联律间期亦不恒定。72例PVC触发的单形VT患者每天PVC次数为15 427±1 109,QT间期为404±15 ms,孤立PVC联律间期为419±22ms。4例PVC触发PVT/VF患者中3例1天的PVC次数与72例PVC触发的单形VT患者平均PVC次数相当。4例患者的QT间期及孤立PVC联律间期与另72例患者相当。而4例PVT/VF的周长均小于280 ms,明显短于72例VT的平均周长(324±59 ms)。72例单形VT患者发生晕厥比率4.1%;4例PVT/VF患者中发生晕厥者2例。采用激动标测和起搏标测证实4例患者PVC均起源于RVOT间隔侧,经射频导管消融PVC取得成功。结论起源于RVOT的PVC触发PVT/VF具有PVC联律间期不恒定及PVT/VF的周长短的临床特征,射频导管消融治疗有效。  相似文献   

19.
特发性左心室流出道心外膜侧室性心动过速   总被引:2,自引:0,他引:2  
目的报道9例经电生理检查证实的特发性左心室流出道心外膜侧室性心动过速(室速)的体表心电图及电生理检查特点.方法男性5例,女性4例,年龄15~58岁,6例为运动诱发的持续性室速,3例为运动诱发的非持续性室速.结果室速时,9例体表心电图QRS波全部呈现右束支阻滞图形(8例胸前导联V1-V6呈现高R波),Ⅱ、Ⅲ、aVF导联为高R波,Ⅰ、aVL导联为QS波.电生理检查,右心室和左心室心内膜标测未发现最早心室激动点,在较早心室心内膜激动处的心内电图多呈现起始部低幅电位,提示远场电位.心室内起搏标测未发现与室速体表心电图12导联QRS波形态相同的起搏点.8例通过心脏静脉系统标测发现最早的心室激动点[体表心电图最早QRS波前15~50ms,平均(32±12)ms]和完全或近乎完全的起搏标测位于心大静脉的远端1例、心前间隔静脉的近端7例.1例患者在左心室流出道消融成功,1例患者在心大静脉远端血管内消融成功.其他患者在右心室和/或左心室内消融失败.结论心脏静脉标测可以鉴别出特发性左心室流出道心外膜侧室速.  相似文献   

20.
目的:探讨经射频消融证实的起源于右室流出道间隔部的特发性室性早搏(室早)的心电图特征及心电向量图特征。方法采用 CARDIO-View 心电工作站收集并分析14例经射频消融术证实为右室流出道间隔部特发性室早患者的12导联心电图及 Frank 导联心电向量图参数。结果起源于右室流出道间隔部的特发性室早呈类左束支阻滞图形。12导联心电图胸导联移行指数≥0的有12例(85.7%),V2导联 R 波时限指数<50%的14例(100%), V2导联 R/S 波振幅指数<30%的有13例(92.9%),SV2/RV3指数>1.5的有12例(85.7%)。心电向量图特征为:QRS 环运行方向在 F 面呈 CW 和 CCW 的各有5例(35.7%),H 面呈 CCW的有10例(71.4%),S 面均呈 CW(100%);起始0.04 s,QRS 环振幅逐渐增大,QRS 环方位大部分指向左前下;0.01~0.04 s 向左向量逐渐增加,向前向量逐渐减少;QRS 环最大向量及大部分面积位于左下后。结论心电图对起源于右室流出道间隔部的室早定位诊断具有较高的准确率。起源于右室流出道间隔部的室早有典型的心电向量特征。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号