首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3–5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38–0.67) for the 3F-CRT plan, 0.58 (range: 0.41–0.66) for 4F-CRT, 0.62 (range: 0.43–0.68) for 5F-CRT and 0.69 (range: 0.58–0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p < 0.001 for all comparisons). As expected, the increment of 3D-CRT fields was associated with an improvement of target dose conformity and homogeneity; on the contrary, in the IMRT plans, a better conformity was associated to a worse target dose homogeneity. A significant reduction in terms of Dmean, V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.  相似文献   

2.
An in silico dosimetric evaluation of intensity-modulated radiation therapy (IMRT) vs 3-dimensional conventional radiation therapy (3D-CRT) treatment plans in postmastectomy radiation therapy (PMRT) to the chest wall and regional lymphatics was conducted. Twenty-five consecutive patients with breast cancer referred for locoregional PMRT, stages T2-4 with N1-3, were planned to receive 50?Gy in 25 fractions with IMRT. Additionally, a 3D-CRT plan was generated using identical contours for the clinical target volumes (CTV), planning target volumes (PTV), and organs at risk (OAR). Treatment plans were assessed using dose-volume histogram (DVH) parameters of D98, D95, D50, D2, and homogeneity index for individual CTVs and PTVs. OARs evaluated were ipsilateral and contralateral lungs, heart, spinal cord, and opposite breast. Most DVH parameters pertaining to CTVs and PTVs significantly favored IMRT. V20 for ipsilateral and contralateral lungs, D33 of heart and maximum dose to spinal cord favored IMRT (all p?<?0.001). The mean dose to the opposite breast was significantly lesser with 3D-CRT (5.8?±?1.8?Gy vs 2.0?±?1.0?Gy, p?<?0.001). Thus, except for the mean dose to the opposite breast, the compliance to DVH constraints applied to PTV and OARs were significantly better with IMRT. At a median follow-up of 76 months (7-91), none had locoregional failure or pulmonary or cardiac morbidity. For PMRT, requiring comprehensive irradiation to both chest wall and regional lymphatics, IMRT offers superior dosimetric advantages over 3D-CRT. This was also corroborated by long-term outcomes in these patients treated with IMRT.  相似文献   

3.
4.
5.
目的 比较三维适形(3 D-CRT)、逆向调强(IMRT)及旋转调强(V-MAT)3种部分乳腺外照射(EB-PBI)治疗计划的剂量学差异.方法 选择定位影像资料完整的12例保乳术后行EB-PBI患者,每例患者分别设计3D-CRT、IMRT、V-MAT 3种治疗计划,比较3种计划的靶区剂量分布、危及器官受照剂量及所需机器跳数(MU)和治疗时间.结果 3D-CRT计划的靶区适形度最差,V-MAT计划的处方剂量靶区覆盖率及靶区剂量均匀性最差.3D-CRT计划中患侧肺V5、V10和平均剂量低,而患侧肺V30高;计划间患侧肺V20差异无统计学意义;V-MAT计划中15、20和25 Gy剂量包绕的同侧正常乳腺体积少;对于心脏V5、平均剂量及最大剂量、对侧肺平均剂量、甲状腺平均和最大剂量,IMRT> V-MAT> 3D-CRT,计划间两两比较差异均有统计学意义(z=-2.94 ~ -2.09,P<0.05).3D-CRT、IMRT和V-MAT计划所需MU值分别为417.6 ±34.4、772.8±54.4和631.0±109.0,计划间两两比较差异均有统计学意义(z=-2.93、-2.76、-2.93,P<0.05);V-MAT计划施照时间短.结论 对于部分乳腺癌的放射治疗,旋转调强计划在降低患侧靶区外正常乳腺组织受照射剂量和减少治疗时间方面优势比较明显.  相似文献   

6.
《Medical Dosimetry》2014,39(2):152-158
The purpose is to dosimetrically compare the following 3 delivery techniques: 3-dimensional conformal radiation therapy (3D-CRT), intensity-modulated arc therapy (IMRT), and volumetric-modulated arc therapy (V-MAT) in the treatment of accelerated partial-breast irradiation (APBI). Overall, 16 patients with T1/2N0 breast cancer were treated with 3D-CRT (multiple, noncoplanar photon fields) on the RTOG 0413 partial-breast trial. These cases were subsequently replanned using static gantry IMRT and V-MAT technology to understand dosimetric differences among these 3 techniques. Several dosimetric parameters were used in plan quality evaluation, including dose conformity index (CI) and dose-volume histogram analysis of normal tissue coverage. Quality assurance studies including gamma analysis were performed to compare the measured and calculated dose distributions. The IMRT and V-MAT plans gave more conformal target dose distributions than the 3D-CRT plans (p < 0.05 in CI). The volume of ipsilateral breast receiving 5 and 10 Gy was significantly less using the V-MAT technique than with either 3D-CRT or IMRT (p < 0.05). The maximum lung dose and the ipsilateral lung volume receiving 10 (V10) or 20 Gy (V20) were significantly less with both V-MAT and IMRT (p < 0.05). The IMRT technique was superior to 3D-CRT and V-MAT of low dose distributions in ipsilateral lung (p < 0.05 in V5 and D5). The total mean monitor units (MUs) for V-MAT (621.0 ± 111.9) were 12.2% less than those for 3D-CRT (707.3 ± 130.9) and 46.5% less than those for IMRT (1161.4 ± 315.6) (p < 0.05). The average machine delivery time was 1.5 ± 0.2 minutes for the V-MAT plans, 7.0 ± 1.6 minutes for the 3D-CRT plans, and 11.5 ± 1.9 minutes for the IMRT plans, demonstrating much less delivery time for V-MAT. Based on this preliminary study, V-MAT and IMRT techniques offer improved dose conformity as compared with 3D-CRT techniques without increasing dose to the ipsilateral lung. In terms of MU and delivery time, V-MAT is significantly more efficient for APBI than for conventional 3D-CRT and static-beam IMRT.  相似文献   

7.
Conformal 3D radiotherapy (3D-CRT) combined with chemotherapy for inoperable non–small cell lung cancer (NSCLC) to the preferable high dose is often not achievable because of dose-limiting organs. This reduces the probability of regional tumor control. Therefore, the surplus value of using intensity-modulated radiation therapy (IMRT) techniques, specifically volumetric modulated arc therapy (RapidArc [RA]) and dynamic IMRT (d-IMRT) has been investigated. RA and d-IMRT plans were compared with 3D-CRT treatment plans for 20 patients eligible for concurrent high-dose chemoradiotherapy, in whom a dose of 60 Gy was not achievable. Comparison of dose delivery in the target volume and organs at risk was carried out by evaluating 3D dose distributions and dose-volume histograms. Quality of the dose distribution was assessed using the inhomogeneity and conformity index. For most patients, a higher dose to the target volume can be delivered using RA or d-IMRT; in 15% of the patients a dose ≥60 Gy was possible. Both IMRT techniques result in a better conformity of the dose (p < 0.001). There are no significant differences in homogeneity of dose in the target volume. IMRT techniques for NSCLC patients allow higher dose to the target volume, thus improving regional tumor control.  相似文献   

8.
To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V20/30, and mean dose of the left kidney, as well as the V20/30 of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V20 of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future.  相似文献   

9.

Purpose

The goal of the present work was to assess the potential advantage of intensity-modulated radiotherapy (IMRT) over three-dimensional conformal radiotherapy (3D-CRT) planning in pelvic Ewing’s sarcoma.

Patients and methods

A total of 8 patients with Ewing sarcoma of the pelvis undergoing radiotherapy were analyzed. Plans for 3D-CRT and IMRT were calculated for each patient. Dose coverage of the planning target volume (PTV), conformity and homogeneity indices, as well as further parameters were evaluated.

Results

The average dose coverage values for PTV were comparable in 3D-CRT and IMRT plans. Both techniques had a PTV coverage of V95 >?98?% in all patients. Whereas the IMRT plans achieved a higher conformity index compared to the 3D-CRT plans (conformity index 0.79?±?0.12 vs. 0.54?±?0.19, p?=?0.012), the dose distribution across the target volumes was less homogeneous with IMRT planning than with 3D-CRT planning. This difference was statistically significant (homogeneity index 0.11?±?0.03 vs. 0.07?±?0.0, p?=?0.035). For the bowel, Dmean and D1%, as well as V2 to V60 were reduced in IMRT plans. For the bladder and the rectum, there was no significant difference in Dmean. However, the percentages of volumes receiving at least doses of 30, 40, 45, and 50 Gy (V30 to V50) were lower for the rectum in IMRT plans. The volume of normal tissue receiving at least 2 Gy (V2) was significantly higher in IMRT plans compared with 3D-CRT, whereas at high dose levels (V30) it was significantly lower.

Conclusion

Compared to 3D-CRT, IMRT showed significantly better results regarding dose conformity (p?=?0.012) and bowel sparing at dose levels above 30 Gy (p?=?0.012). Thus, dose escalation in the radiotherapy of pelvic Ewing’s sarcoma can be more easily achieved using IMRT.  相似文献   

10.
目的 评估螺旋断层调强放疗(helical tomotherapy,HT)、常规直线加速器逆向调强放疗(IMRT)和三维适形放疗(3D- CRT)3种治疗计划对乳腺癌术后胸壁照射的剂量影响和正常组织受照剂量体积对比。方法 选择10例早期乳腺癌改良根治术后患者CT定位图像,由同一医生勾画PTV,统一处方剂量50 Gy/ 25次。每例图像分别做HT、IMRT和3D- CRT 3种治疗计划,并对心脏、健侧肺和患侧肺受照射剂量体积、靶区适形度指数、剂量均匀指数和处方剂量所覆盖的靶体积等物理参数进行比较。结果 95%和100%的处方剂量覆盖的PTV体积在HT、IMRT和3D- CRT组分别为99.13%和95.87%、97.80%和94.05%、96.37%和87.29%。HT、IMRT 和3D-CRT组的适形指数和靶区均匀指数分别为0.80±0.10和1.09±0.03、0.65±0.07和1.14±0.02、0.40±0.08和1.17±0.04。心脏V5~V20以3D- CRT组最少,其次是HT组。患侧肺V5接受的照射剂量体积以3D- CRT组最小,与HT和IMRT两组相比差异均有统计学意义。健侧肺V5V10以3D- CRT组最少。结论 乳腺癌术后胸壁照射的靶区适形度和剂量均匀指数HT组最好;心脏、健侧肺和患侧肺低剂量区最小的依次是3D-CRT、HT和IMRT组。  相似文献   

11.
A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V20Gy and V30Gy dose levels (range, 4.62–17.98%) compared with IMRT plans. The mean dose and D35% of heart for the RA plans were better than the IMRT by 0.5–5.8%. Mean V10Gy and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15–20 Gy) in the range of 14–16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20–25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.  相似文献   

12.
The purpose of this planning study was to determine whether intensity-modulated radiation therapy (IMRT) reduces the radiation dose to organs at risk (OAR) when compared with 3D conventional radiation therapy (3D-CRT) in patients with vulvar cancer treated by irradiation. This study also investigated the use of sequential IMRT boost (seq-IMRT) and simultaneous integrated boost (SIB-IMRT) for dose escalation in the treatment of locally advanced vulvar cancer. Five vulvar cancer patients treated in the postoperative setting and 5 patients treated with definitive intent (def-group) were evaluated. For the postoperative group, 3D-CRT and IMRT plans to a total dose (TD) of 45 Gy were generated. For the def-group, 4 plans were generated: a 3D-CRT and an IMRT plan to a TD of 56.4 Gy, a SIB-IMRT plan to a TD of 56 Gy, and a SIB-IMRT with dose escalation (SIB-IMRT-esc): TD of 67.2 Gy. Mean dose and dose-volume histograms were compared using Student's t-test. IMRT significantly (all p < 0.05) reduced the Dmean, V30, and V40 for all OAR in the adjuvant setting. The V45 was also significantly reduced for all OAR except the bladder. For patients treated in the def-group, all IMRT techniques significantly reduced the Dmean, V40, and V45 for all OAR. The mean femur doses with SIB-IMRT and SIB-IMRT-esc were 47% and 49% lower compared with 3D-CRT. SIB-IMRT-esc reduced the doses to the OAR compared with seq-3D-CRT but increased the Dmax. for the small bowel, rectum, and bladder. IMRT reduces the dose to the OAR compared with 3D-CRT in patients with vulvar cancer receiving irradiation to a volume covering the vulvar region and nodal areas without compromising the dosimetric coverage of the target volume. IMRT for vulvar cancer is feasible and an attractive option for dose escalation studies.  相似文献   

13.
目的比较食道癌在调强放疗与三维适形放疗中靶区剂量及正常组织照射量。方法从我院食道癌患者中抽取10例并由同一肿瘤医师在定位图像上勾画靶区及正常组织,在所勾画的靶区上分别作调强计划与三维适形计划,并以PTV95%、GTV95%、CI、HI、脊髓最大剂量以及左右肺V20来作为剂量评估指标,并进行统计学分析。结果统计学分析结果表明,三维适形放疗与调强放疗的各项指标之间的差异均有统计学意义。结论调强放疗在食道癌的治疗中无论是从靶区剂量的调控还是正常组织剂量的约束上都明显优于三维适形放疗,是食道癌放射治疗中的一种有效治疗方案。  相似文献   

14.
基于食管癌放射治疗计划的剂量学研究   总被引:3,自引:0,他引:3  
目的应用三维治疗计划系统(3D—TPS)比较研究食管癌的不同照射方法,评价常规三野等中心照射(RT)、三维适形(3D~CRT)、调强适形放射治疗(IMRT)在靶区剂量及正常组织保护方面的不同。方法采用三维治疗计划系统对12例经病理证实的中下段食管癌的患者CT定位图像分别设计3种放射治疗计划,分别为RT,3 D—CRT,IMRT,计划的处方剂量均为50 Gy,通过治疗计划及剂量体积直方图(DVH)比较靶区及危及器官剂量的差异。结果RT,3 D—CRT,IMRT的95%计划靶体积(PTV)及95%大体肿瘤体积(GTV)的剂量有统计学意义,3 D—CRT和IMRT优于RT;3种计划的靶区适形度指数、PTV剂量变异度指数、处方剂量覆盖GTV百分比均以IMRT计划为最好,3D—CRT、IMRT减少了双肺受照20 Gu体积百分比(V20),均有统计学意义;3种计划的脊髓最大所受剂量、心脏1/3体积的所受剂量均在可耐受的范围内,IMRT为最小,P〉0.05。结论3 D—CRT、IMRT在靶区适形度和靶区剂量上均优于RT,能获得均匀的剂量分布,且能降低周围敏感器官的所受剂量,正常组织所受剂量均能在耐受范围内。  相似文献   

15.
目的 比较胸段食管癌3种放疗技术( 3D-CRT、IMRT、RapidArc)的剂量学特点,并分析3种技术的优劣及应用特点.方法 15例胸段食管癌患者入组,依据CT图像,勾画靶区,针对患者的同一套CT图像的相同靶区分别制定3D-CRT、5野IMRT(IMRT5)、7野IMRT( IMRT7)、9野IMRT(IMRT9)、单弧Arc( Arc1)、双弧Arc( Arc2)共6套计划.PTV处方剂量为40 Gy分20次4周+19.6 Gy分14次7d.结果 3D-CRT计划各项靶区剂量学参数明显差于IMRT计划及RapidArc计划(t=5.77、3.52,P<0.05),6套计划的PTV V95(%)分别为:3D-CRT (91.55 ±2.90),IMRT5(96.66±1.05),IMRT7 (96.87±1.23),IMRT (96.81±1.16),Arcl (94.98±1.41),Arc2 (95.93±1.32).RapidArc计划的靶区适形度(CI)最好(t=3.76,10.01,P<0.05),IMRT计划的靶区均匀性(HI)最好(t =3.93、3.37,P<0.05).危及器官参数RapidArc与IMRT各计划之间差异无统计学意义.3D-CRT和RapidArc计划的机器跳数明显少于IMRT计划,差异高达75%.结论 对于胸段食管癌患者,采用IMRT或RapidArc技术可以在保护正常组织的同时,涵盖临床必需的治疗靶区.3D-CRT计划对降低正常组织低剂量散射区方面优势明显.RapidArc计划靶区剂量学参数与IMRT计划比较未见明显优势.  相似文献   

16.
17.
Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal Dmax of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal Dmean, Dmax, D1cc, D4%, and V20 Gy compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V95% (p = 0.01) and Dmean (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at risk, whereas for IMRT it is compromised target coverage. These findings suggest clinical situations where each technique may be most useful if DS constraints are to be employed.  相似文献   

18.
19.

Purpose

To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession.

Patients and methods

This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2–3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1–3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose <?54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated.

Results

The qVMAT method gave rise to significantly improved PTV95% and conformity index (CI) values in comparison to 3D-CRT (PTV95%?=?90.7?% vs. 82.0?%; CI?=?0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95%?=?94.4?%, CI?=?0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95%?=?88.5?% and 92.3?%, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT.

Conclusion

These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery.  相似文献   

20.

Purpose

The goal of this research was to investigate the feasibility of volumetric modulated arc therapy, RapidArc (RA), in association with the active breathing coordinator (ABC) for the treatment of hepatocellular carcinoma (HCC) with radiotherapy.

Patients and materials

A total of 12?patients with HCC, after receiving transcatheter arterial chemoembolization (TACE) treatment, underwent three-dimensional computer tomography (3D-CT) scanning associated with ABC using end inspiration hold (EIH), end expiration hold (EEH), and free breathing (FB) techniques. The three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and RA plans (three 135° arcs) were designed on different CT images, respectively. The liver volume, gross tumor volume (GTV), and planning target volume (PTV) of the three breath status and the dosimetric differences of the different plans were compared.

Results

There were no significant differences in the volumes of live and GTV between the three breathing techniques (p?>?0.05); the PTV in FB was greater than in the EEH and EIH (p?20, V30, and V40 of normal liver compared to 3D-CRT, while the V5 and V10 in RA were higher than in IMRT. The mean values in mean dose, V10, V20, V30, and V40 of the normal liver were reduced from 13.12?Gy, 46%, 24%, 13%, and 8% in RAFB to 10.23?Gy, 35%, 16%, 8%, and 5% in RAEEH and 9.23?Gy, 32%, 16%, 8%, and 5% in RAEIH?, respectively. In addition, the treatment time of RA was equal to 3D-CRT, which was significantly shorter than IMRT.

Conclusion

RA in conjunction with ABC for the treatment of HCC with radiotherapy can achieve better dose delivery and ensure the accuracy of the target volume, which spares more organs at risk, uses fewer monitor units, and shortens treatment time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏