首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose:

The aim of this study is to evaluate whether two 3.0 mm Schanz screws in two-part proximal humeral fractures (plus one additional Schanz screw or K wire in three-part fractures) can provide enough stability to allow early mobilization until healing occurs in elderly patients.

Settings and Design:

This prospective study was performed in the Orthopaedic Department of our University Hospital.

Patients and Methods:

We performed closed reduction and percutaneous pinning for thirty-three patients with proximal humerus fractures. Twenty-seven patients were available for the final follow-up. Of those 27 patients, 17 had two-part surgical neck fractures; while 10 had three-part fractures. For fixation, we used two 3.0 mm Schanz screws in patients with two-part fractures plus one additional Schanz screw or K wire in the 10 patients with three-part fractures.

Results:

The mean Constant score modified according to the age and sex was 89.8% (range: 77.3-97.2%). Fifteen patients had excellent results, 11 patients had good results, and one patient had a fair result.

Conclusion:

Closed reduction and percutaneous pinning with two Schanz screws for two-part surgical neck humeral fractures, plus an additional Schanz screw or K wire for three-part proximal humeral fractures is a useful and effective technique that provides enough stability to allow an early rehabilitation program till union occurs in elderly patients.

Level of Evidence:

IV; therapeutic study, case series.  相似文献   

2.

Purpose

The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively.

Methods

Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix® (MTS® Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded.

Results

The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406).

Conclusion

The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.  相似文献   

3.

Introduction:

Total shoulder resurfacing (TSR) provides a reliable solution for the treatment of glenohumeral arthritis. It confers a number of advantages over traditional joint replacement with stemmed humeral components, in terms of bone preservation and improved joint kinematics. This study aimed to determine if humeral reaming instruments produce a thermal insult to subchondral bone during TSR.

Patients and Methods:

This was tested in vivo on 13 patients (8 with rheumatoid arthritis and 5 with osteoarthritis) with a single reaming system and in vitro with three different humeral reaming systems on saw bone models. Real-time infrared thermal video imaging was used to assess the temperatures generated.

Results:

Synthes (Epoca) instruments generated average temperatures of 40.7°C (SD 0.9°C) in the rheumatoid group and 56.5°C (SD 0.87°C) in the osteoarthritis group (P = 0.001). Irrigation with room temperature saline cooled the humeral head to 30°C (SD 1.2°C). Saw bone analysis generated temperatures of 58.2°C (SD 0.79°C) in the Synthes (Epoca) 59.9°C (SD 0.81°C) in Biomet (Copeland) and 58.4°C (SD 0.88°C) in the Depuy Conservative Anatomic Prosthesis (CAP) reamers (P = 0.12).

Conclusion:

Humeral reaming with power driven instruments generates considerable temperatures both in vivo and in vitro. This paper demonstrates that a significant thermal effect beyond the 47°C threshold needed to induce osteonecrosis is observed with humeral reamers, with little variation seen between manufacturers. Irrigation with room temperature saline cools the reamed bone to physiological levels and should be performed regularly during this step in TSR.  相似文献   

4.

Background:

The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD), diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws.

Materials and Methods:

Sixty fresh human cadaveric vertebrae (D10–L2) were harvested. Dual-energy X-ray absorptiometry (DEXA) scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm) were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a) standard pedicle screw (no cortical perforation); b) screw with medial cortical perforation; and c) screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine.

Results:

Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra (P = 0.105), but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD (P = 0.901).

Conclusion:

The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.  相似文献   

5.
Effect of screw placement on fixation in the humeral head   总被引:9,自引:0,他引:9  
The objectives of this study were (1) to determine the most advantageous screw locations within the humeral head when plate and screw fixation is to be used and (2) to determine the effect of positioning the screw tip abutting the subchondral bone. Ten paired humeral heads were harvested with a monoplanar cut through the anatomic neck. Through use of a standardized template, 7 holes were drilled and tapped in each specimen for insertion of 6.5-mm fully threaded cancellous screws perpendicular to the plane of the cut. Paired specimens were randomized into 2 groups, one with the screw purchase in central cancellous bone and the other with the screw purchase up to the subchondral bone. Each screw was pulled out axially at a displacement rate of 10 mm/min through use of a servohydraulic testing machine. The length of thread purchase, position within the head, and screw pullout load to failure were recorded. The normalized pullout force to failure was calculated by dividing absolute pullout force to failure by length of screw purchase. Data were analyzed by means of a 2-way repeated measures analysis of variance and post hoc Student-Newman-Keuls test. The central position had a significantly higher absolute pullout force to failure than all other sites (P < .05). By virtue of the humeral head shape, the central position also had a significantly greater length of screw purchase than all other positions (P < .05). The central position had a significantly higher relative pullout force to failure than all other positions (P < .05). Subchondral bone abutment positioning improved both the absolute and the relative pullout forces to failure (P < .05). When screws and plates are used in open reduction and internal fixation of a proximal humerus fracture, a major mode of failure is loss of fixation within the humeral head. On the basis of this study, optimal screw purchase with respect to bone fixation can be achieved by including screws located in the center of the humeral head in the subchondral abutment position. To minimize screw fixation failure, the anterosuperior position should be avoided. The pattern of distribution of the relative pullout force as measured in this study is consistent with previous observational studies of patterns of trabecular density within the humeral head.  相似文献   

6.

Context:

It is agreed that it is important to anatomically reproduce the proximal humeral anatomy when performing a prosthetic shoulder replacement. This can be difficult with a long stemmed prosthesis, in particular if there is little relationship of the metaphysis to the humeral shaft. The ‘short stem’ prosthesis can deal with this problem.

Aims:

A prospective study assessed the results of total shoulder arthroplasty using a short stem humeral prosthesis, a ceramic humeral head, and a pegged cemented polyethylene glenoid.

Materials and methods:

Patients with primary shoulder osteoarthritis were recruited into this prospective trial and pre-operatively had the ASES, Constant, SPADI, and DASH scores recorded. The patients were clinically reviewed at the two weeks, eight weeks, one year, and two year mark with completion of a data form. Radiological evaluation was at the eight week, one year and two year follow-up. At the one and two year follow-up the satisfaction rating, the range of passive and active motion, Constant, ASES, SPADI, DASH and pain results were recorded and analysed with SPPS 20.

Results:

During the study period 97 short stem, ceramic head total shoulder replacements were carried out. At the time of follow-up 12 were two years from operation and 38 one year from operation. Active elevation was overall mean 160 degrees. Constant scores were 76 at 1 year, and 86 at 2 years, ASES 88 and 93, and satisfaction 96% and 98% respectively at one and 2 year follow up. There were no problems during insertion of the humeral prosthesis, or any radiolucent lines or movement of the prosthesis on later radiographs.

Conclusion:

The short stem prosthesis had no complications, and on follow up radiographs good bone fixation. These fairly short term clinical results were overall good.  相似文献   

7.

Background:

Neglected intracapsular femoral neck fracture in young patients may fail to unite because of the excessive shearing strain at the fracture site and it is a surgical challenge to any orthopedic surgeon. The problem is compounded by resorption of the femoral neck and avascular necrosis (AVN) of femoral head. There is no satisfactory solution available in the management of femoral neck fracture as far as the union of the fracture and AVN of femoral head are concerned. Muscle pedicle bone grafting has been advocated to provide additional blood supply to the femoral head. We report a retrospective analysis of 48 cases of neglected femoral neck fracture treated by internal fixation and tensor fascia latae based muscle pedicle bone grafting.

Materials and Methods:

48 patients with femoral neck fractures with age varied from 20 to 53 years (average age 32.9 years) with male to female ratio of 2:1 were enrolled. All fractures were more than 3 weeks old with mean delay being 86 days (22–150 days). Open reduction and internal fixation along with tensor fascia latae muscle pedicle bone grafting was done in all cases. It was supplemented by multiple drilling and cortico-cancellous bone grafting. Fracture fixation was done with three parallel 6.5-mm AO cannulated cancellous lag screws and the graft fixed with a 4-mm cancellous screw to provide a secure fixation. During the followup period of 2-6.8 years (average 4.4 years) the results were assessed clinically by modified Harris hip scoring system and radiologically by the evidence of signs of fracture union.

Results:

Union was achieved in 41/48 (85.41%) cases which were followed for an average period of 4.4 years (2–6.8 years) with good functional results and ability to squat and sit cross-legged. Results were assessed according to modified Harris Hip Scoring system and found to be excellent in 19, good in 22, fair in 5, and poor in 2 patients. Complications were nonunion, (n=3) avascular necrosis (n=2), and coxa vara deformity (n=2).

Conclusion:

Internal fixation with muscle pedicle bone grafting is a suitable option to secure union in neglected femoral neck fractures in physiologically active patients with late presentation.  相似文献   

8.

Background:

With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation.

Materials and Methods:

12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise.

Results:

At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred.

Conclusion:

We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.  相似文献   

9.

Background:

Femoral neck fractures are treated either by internal fixation or arthroplasty. Usually, cannulated cancellous screws are used for osteosynthesis of fracture neck of femur. The bone impregnated hip screw (BIHS) is an alternative implant, where osteosyntehsis is required in femoral neck fracture.

Materials and Methods:

The BIHS is a hollow screw with thread diameter 8.3 mm, shank diameter 6.5 mm and wall thickness 2.2 mm and holes in the shaft of the screw with diameter 2 mm, placed in a staggered fashion. Biomechanical and animal experimental studies were done. Clinical study was done in two phases: Phase 1 in a group of volunteers, only with BIHS was used in a pilot study and phase 2 comparative study was done in a group with AO cannulated screws and the other group treated with BIHS.

Results:

In the phase 1 study, out of 15 patients, only one patient had delayed union. In phase 2, there were 78 patients, 44 patients in BIHS showed early union, compared to the rest 34 cases of AO cannulated screws Out of 44 patients with BIHS, 41 patients had an excellent outcome, 2 had nonunions and one implant breakage was noted.

Conclusions:

Bone impregnated hip screw has shown to provide early solid union since it incorporates the biomechanical principles and also increases the osteogenic potential and hence, found superior to conventional cannulated cancellous screw.  相似文献   

10.

Background:

Autologous cancellous bone is the most effective biological graft material. However, harvest of autologous bone is associated with significant morbidity. Since porous hydroxyapatite and beta-tricalcium phosphate are biodegradable materials and can be replaced by bone tissue, but it lacks osteogenic property. We conducted a study to assess their use as a scaffold and combine them with bone marrow aspirate for bone regeneration using its osteogenic property for posterolateral spinal fusion on one side and autologous bone graft on the other side and compare them radiologically in terms of graft incorporation and fusion.

Materials and Methods:

Thirty patients with unstable dorsal and lumbar spinal injuries who needed posterior stabilization and fusion were evaluated in this prospective study from October 2005 to March 2008. The posterior stabilization was done using pedicle screw and rod assembly, and fusion was done using hydroxyapatite and beta-tricalcium phosphate mixed with bone marrow aspirate as a bone graft substitute over one side of spine and autologous bone graft obtained from iliac crest over other side of spine. The patients were followed up to a minimum of 12 months. Serial radiographs were done at an interval of 3, 6, and 12 months and CT scan was done at one year follow-up. Graft incorporation and fusion were assessed at each follow-up. The study was subjected to statistical analysis using chi-square and kappa test to assess graft incorporation and fusion.

Results:

At the end of the study, radiological graft incorporation and fusion was evident in all the patients on the bone graft substitute side and in 29 patients on the autologous bone graft side of the spine (P > 0.05). One patient showed lucency and breakage of distal pedicle screw in autologous bone graft side. The interobserver agreement (kappa) had an average of 0.72 for graft incorporation, 0.75 for fusion on radiographs, and 0.88 for the CT scan findings.

Conclusion:

Hydroxyapatite and beta-tricalcium phosphate mixed with bone marrow aspirate seems to be a promising alternative to conventional autologous iliac bone graft for posterolateral spinal fusion.  相似文献   

11.

Background:

Femoral neck fractures are notorious for complications like avascular necrosis and nonunion. In developing countries, various factors such as illiteracy, low socioeconomic status, ignorance are responsible for the delay in surgery. Neglected fracture neck femur always poses a formidable challenge. The purpose of this study was to evaluate the results of triple muscle pedicle bone grafting using sartorius, tensor fasciae latae and part of gluteus medius in neglected femoral neck fracture.

Materials and Methods:

This is a retrospective study with medical record of 50 patients, who were operated by open reduction, internal fixation along with muscle pedicle bone grafting by the anterior approach. After open reduction, two to three cancellous screws (6.5 mm) were used for internal fixation in all cases. A bony chunk of the whole anterior superior iliac spine of 1 cm thickness, 1 cm width and 4.5 cm length, taken from the iliac crest comprised of muscle pedicle of sartorius, tensor fascia latae and part of gluteus medius. Then the graft with all three muscles mobilized and put in the trough made over the anterior or anterosuperior aspect of the femoral head. The graft was fixed with one or two 4.5 mm self-tapping cortical screw in anterior to posterior direction.

Results:

14 patients were lost to followup. The results were based on 36 patients. We observed that in our series, there was union in 34, out of 36 (94.4%) patients. All patients were within the age group of 15-51 years (average 38 years) with displaced neglected femoral neck fracture of ≥30 days. Mean time taken for full clinicoradiological union was 14 weeks (range-10-24 weeks).

Conclusion:

Triple muscle pedicle bone grafting gives satisfactory results for neglected femoral neck fracture in physiologically active patients.  相似文献   

12.

Purpose:

Chronic rupture of the long head of biceps (LHB) tendon is usually asymptomatic. However, some active patients suffer with long-term cramping pain associated with repetitive biceps use. The aim of this study is to review the outcomes of biceps tenodesis performed for chronic LHB ruptures.

Materials and Methods:

We performed a retrospective review of 11 consecutive patients who underwent biceps tenodesis for symptomatic chronic LHB ruptures over a 4-year period.

Results:

There were 10 men and one woman with an average age at surgery of 41 years (range 23-65). The mean follow-up was 29 months (range 6-60). In five cases a tendon was still identifiable and suitable for repair with an ‘in-bone’ interference screw. However, in six cases the tendon was not possible to tenodese with an interference screw. In these cases we used an ‘on-bone’ technique with suture anchors. All, except one, patients reported improvement in their arm pain (78%), strength (74%) and appearance. All, except one, were glad to have had the surgery.

Conclusions:

Symptomatic chronic LHB ruptures improve with a biceps tenodesis procedure. Due to the chronicity of the injury and possible degeneration of the tendon, a suitable tendon for ‘in-bone’ tenodesis may not be possible. In these cases an ‘on-bone’ footprint repair with suture anchors achieves good results.

Level of Evidence:

IV (retrospective case series).  相似文献   

13.

Introduction:

Non-union following fracture of the proximal humerus is not uncommon, particularly in the elderly. This can be associated with significant morbidity due to pain, instability and functional impairment. The Polarus device (Acumed) is a locked, antegrade intramedullary nail designed to stabilize displaced 2-, 3- and 4-part fractures of the proximal humerus. We report our experience with the Polarus nail for the treatment of established non-union of the proximal humerus.

Materials and Methods:

A total of 7 Polarus nails were inserted for the treatment of non-union of the proximal humerus between June 2000 and July 2007. Each fracture site was opened, debrided, stabilized with a Polarus nail and then grafted with autologous cancellous iliac crest bone. The time between injury and surgery ranged from 6 to 102 months. One patient had undergone previous fixation of her fracture using Rush intramedullary rods. All patients were females, and mean age at surgery was 63.6 years (range, 49-78 years). A retrospective review of notes and radiographs was carried out. Patients were reviewed at varying intervals postoperatively (range, 13-68 months) and assessed using the Constant shoulder-scoring system.

Results:

All un-united fractures progressed to union. There were no wound complications and no postoperative nerve palsies. Functional outcome was good, even in those cases with a long interval between injury and surgery. The mean Constant score was 63 (range, 54-81). Migration of a single proximal locking screw was seen in 2 patients, and these screws required removal at 5 and 12 months, respectively, postoperatively.

Conclusion:

In our experience, a locked proximal humeral nail used in conjunction with autologous bone grafting is an excellent device for the treatment of proximal humerus non-unions.  相似文献   

14.

Objective:

To evaluate a new biodegradable copolymer calcium sulfate/poly amino acid (CS/PAA) as a graft substitute for the repair of the surgically created cancellous bone defects in rabbits and its biological properties in vivo.

Materials and Methods:

Cancellous bone defects were created by drilling holes in the unilateral lateral aspect of the femoral condyle of New Zealand white rabbits. Three groups were assigned: Group A rabbits were grafted with 80% CS/PAA and group B rabbits were grafted with 95% CS/PAA as two treatment groups; group C was sham-operation control group. To study the osteogenic capability in vivo, specimens were harvested at 4, 8, 12, and 16 weeks after implantation and were evaluated by gross assessment, X-ray, histological examination, and histomorphometry. In order to identify the molecular mechanism of bone defect repair, the expression of bone morphogenetic protein-2 (BMP-2) and vascular endothelial growth factor (VEGF) was detected using Western blot at 4 weeks.

Results:

Group A and group B showed more vigorous and rapid repair leading to regeneration of cancellous bone than sham-operation control group on gross observation, radiology, and histomorphometry. There was no significant difference between groups A and B. Morphological observation and histological examination showed that the copolymers degraded in sync with the new bone formation process. The expression of BMP-2 and VEGF in implantation groups was higher than that in control group by western blot.

Conclusion:

These findings demonstrated that the novel biodegradable copolymers can repair large areas of cancellous bone defects. With its controllable degradation rate, it suggests that CS/PAA may be a series of useful therapeutic substitute for bone defects.  相似文献   

15.

Background

Iliosacral screw fixation has become a common method for surgical stabilization of acute disruptions of the pelvic ring. Placement of iliosacral screws into the first sacral (S1) body is the preferred method of fixation, but size limitations and sacral dysmorphism may preclude S1 fixation. In these clinical situations, fixation into the second sacral (S2) body has been recommended. The objective of this study was to evaluate the bone quality of the S1 compared to S2 in the described “safe zone” of iliosacral screw fixation in trauma patients.

Materials and methods

The pelvic computed tomography scans of 25 consecutive trauma patients, ages 18–49, at a level 1 trauma center were prospectively analyzed. Hounsfield units, a standardized computed tomography attenuation coefficient, was utilized to measure regional cancellous bone mineral density of the S1 and S2. No change in the clinical protocol or treatment occurred as a consequence of inclusion in this study.

Results

A statically significant difference in bone quality was found when comparing the first and second sacral segment (p = 0.0001). Age, gender, or smoking status did not independently affect bone quality.

Conclusion

In relatively young, otherwise healthy trauma patients there is a statistically significant difference in the bone density of the first sacral segment compared to the second sacral segment. This study highlights the need for future biomechanical studies to investigate whether this difference is clinically relevant. Due to the relative osteopenia in the second sacral segment, which may impact the quality of fixation, we feel this technique should be used with caution.

Level of evidence

III  相似文献   

16.

Background:

Transarticular screw placement needs highly accurate imaging. We assess the efficacy and accuracy of C1-C2 transarticular screw fixation using neuronavigation and also cast a technical note on the procedure.

Materials and Methods:

This study included a total of nine patients who underwent transarticular screw fixation using the neuronavigation system. A total of 15 screws were placed. All patients underwent postoperative CT scan with 3-Dimensional (3-D) reconstruction to check for the accuracy of implantation.

Results:

One patient had encroachment of the transverse foramen but there was no vertebral artery injury. There were no clinical complications or adverse sequelae.

Conclusion:

Neuronavigation is extremely helpful in C1-C2 transarticular screw fixation and gives excellent accuracy.  相似文献   

17.

Background:

Acetabular fracture involves whether superior articular weight bearing area and stability of the hip are assessed by acetabular roof arc angles comprising medial, anterior and posterior. Many previous studies, based on clinical, biomechanics and anatomic superior articular surface of acetabulum showed different degrees of the angles. Anatomic biomechanical superior acetabular weight bearing area (ABSAWBA) of the femoral head can be identified as radiographic subchondral bone density at superior acetabular dome. The fracture passes through ABSAWBA creating traumatic hip arthritis. Therefore, acetabular roof arc angles of ABSAWBA were studied in order to find out that the most appropriate degrees of recommended acetabular roof arc angles in the previous studies had no ABSAWBA involvement.

Materials and Methods:

ABSAWBA of femoral head was identified 68 acetabular fractures and 13 isolated pelvic fractures without unstable pelvic ring injury were enrolled. Acetabular roof arc angle was measured on anteroposterior, obturator and iliac oblique view radiographs of normal contralateral acetabulum using programmatic automation controller digital system and measurement tools.

Results:

Average medial, anterior and posterior acetabular roof arc angles of the ABSAWBA of 94 normal acetabulum were 39.09 (7.41), 42.49 (8.15) and 55.26 (10.08) degrees, respectively.

Conclusions:

Less than 39°, 42° and 55° of medial, anterior and posterior acetabular roof arc angles involve ABSAWBA of the femoral head. Application of the study results showed that 45°, 45° and 62° from the previous studies are the most appropriate medial, anterior and posterior acetabular roof arc angles without involvement of the ABSAWBA respectively.  相似文献   

18.

Background

Several studies reported high failures rates after internal fixation of proximal humerus fractures. Loss of reduction and screw cut-out are the most common reasons for revision surgery. Several risk factors for failure have been described in the literature. The aim of the present study was to assess risk factors for failure after surgical fixation of unstable proximal humerus fractures in a multivariate setup.

Methods

Two different surgical techniques (PHILOS locking plate and Humerusblock) were used. In the PHILOS group, every kind of postoperative relative movement between the implant and the humeral head or shaft was defined as failure. In the Humerusblock group, postoperative movement between the humeral head and the shaft in terms of angulation or translational displacement was defined as failure. The following parameters were assessed: age, gender, cancellous bone mineral density (BMD) of the humeral head, fracture type, medial metaphyseal comminution, medial metaphyseal head extension, initial angulation of the humeral head in the frontal plane, initial anteversion of the humeral head, medial hinge displacement, maximum displacement of the tuberosities with respect to the head, surgical technique, anatomic reconstruction and restoration of the medial cortical support.

Results

The following parameters were found to have a significant influence on the failure rate: age, local BMD, anatomic reduction, and restoration of the medial cortical support. The failure rate significantly increased with the number of risk factors.

Conclusion

Preoperative assessment of the local BMD and the patients’ biological age as well as intraoperative anatomic reduction and restoration of the medial cortical support are the essentials for successful surgical fixation of proximal humerus fractures. Multifragmentary fracture patterns in old patients with low local BMD are prone for fixation failure. If the surgeon is not able to achieve anatomic reduction and restoration of the medial cortical support intraoperatively in this situation, adjustments such as augmentation or primary arthroplasty should be considered.  相似文献   

19.

Objectives

Osteoarthritis (OA) is increasingly considered a disease of the whole joint, yet the interplay between the articular cartilage and the subchondral bone remains obscure. We here set out to investigate the impact of bone mass on the progression of surgically induced knee OA in the mouse.

Methods

OA was induced in the right knees of female C57BL/6 (low bone mass) and STR/ort (high bone mass) mice via anterior cruciate ligament transection and destabilization of the medial meniscus. At 36 weeks of age, left and right knee joints were histologically compared for cartilage degeneration and via microCT analysis for subchondral bone plate thickness. In addition, femora were analyzed for bone mass at diaphysis and distal meta- and epiphysis.

Results

The severity of cartilage deterioration did not differ under high and low bone mass conditions. However, the extent of bone sclerosis differed and was proportional to the baseline subchondral bone plate thickness. Moreover, the cancellous bone loss following OA progression was inversely related to the bone mass: high bone mass restricted the loss to the epiphysis, whereas low bone mass allowed for a more widespread loss extending into the metaphysis.

Conclusions

Our results suggest that cartilage degeneration is independent of the underlying bone mass. In contrast, subchondral bone remodeling associated with OA progression seem to correlate with the initial bone mass and suggest an enhanced crosstalk between the deteriorating cartilage and the subchondral bone under low bone mass conditions.  相似文献   

20.

Objective

To assess the influence of osteochondral graft preservation techniques on post-transplant biomechanics of graft and host subchondral bone in the knee joint.

Design

An experimental animal model (sheep), specifically the weight-bearing articular surface of the medial femoral condyle of the knee joints.

Intervention

Each sheep received, in the ipsilateral knee, an allograft that was (a) frozen without dimethyl sulfoxide (DMSO), (b) snap-frozen in liquid nitrogen or (c) frozen with DMSO. The contralateral knee received an autograft that was (a) snap-frozen, (b) treated with DMSO or (c) left untreated (fresh).

Main outcome measures

Mechanical and material properties of bone, including maximal compression stress, modulus of elasticity and bone mineral ash content of subchondral bone cores (from the graft centre and surrounding host bone).

Results

No significant differences were found in the mechanical properties of the subchondral bone under the graft, but there were significant changes in surrounding bone. Bone surrounding the grafts that were snap-frozen or frozen without DMSO was significantly stronger than the normal control bone. However, bone surrounding fresh autografts and cryoprotected allografts was not significantly different from normal control bone.

Conclusions

The changes in the mechanical behaviour of the host bone may be associated with graft cell viability. The greater stiffness of the subchondral host bone may have consequences for long-term graft integrity and for the development of degenerative osteoarthritis.  相似文献   