首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two antibodies were prepared for use in a sandwich enzyme immunoassay of human IgG. Completely purified guinea pig anti-human IgG was labelled with beta-D-galactosidase (EC 3.2.1.23), using a heterobifunctional cross-linker named GMBS. Partially purified anti-human IgG was immobilized on a new solid support: Amino-Dylark balls. Optimal conditions for immobilizing the antibody, using glutaraldehyde as the coupling reagent, were studied in detail. With the enzyme-labelled antibody and the solid-phase anti-human IgG, a sandwich enzyme immunoassay of human IgG with a lower limit of detection at 10.5 pM (0.3 ng/tube) was developed. A comparative study of the EIA method and a laser nephelometric method showed a good correlation. The specificity of the assay was excellent: all 4 types of IgG tested showed the maximum 0.0001%; human IgA, IgM and albumin possessed the maximum 0.54% in their cross-reactivity values with human IgG.  相似文献   

2.
The design, development, and application of a fluorescent fiber-optic immunosensor (FFOI) procedure for the detection of antibody/antigen binding within the near-infrared (NIR) spectral region is reported. The technique was developed through the combined use of fiber-optics, semiconductor laser excitation, fluorescence detection, NIR dye, and immunochemical techniques. The antibody is immobilized on the FFOI's sensing tip and utilized as a recognition component for trace amounts of specific antigen. The FFOI is constructed to utilize antibody sandwich technique. Three individual immunoassays are reported. The first two assays utilize the FFOI and NN382, a commercial NIR dye, for the detection of human immunoglobulin G (IgG). In these assays, goat anti-human IgG antibody (GAHG) is immobilized on the sensitive terminal of the FFOI followed by the exposure of the antibody-coated terminal to human IgG. The probe is then introduced to GAHG labeled with NN382, generating a signal. The third assay utilizes the FFOI for the detection of trace amounts of Legionella pneumophila serogroup 1 (LPS1). In this assay, rabbit anti-LPS1 antibody is immobilized on the sensitive terminal of the FFOI followed by exposure to LPS1. The antigen-coated probe is then treated with monoclonal anti-LPS1 antibody followed by incubation with GAHG labeled with NN382. The assays are optimized to detect the corresponding antigen via the NIR-FFOI. Typical measurements are performed in 10-15 min. A 780-nm semiconductor laser provides the excitation of the immune complex and the resulting emission is detected by a 820-nm silicon photodiode detector. The intensity of the resulting fluorescence is directly proportional to the concentration of the antigen. Solutions of IgG and LPS1 with concentrations as low as 10(-11) M and 0.5 ng/ml, respectively, have been detected with a minimum interference.  相似文献   

3.
The Histoplasma antigen immunoassay utilizes an antibody sandwich method that provides a rapid and reliable means of diagnosing the more severe forms of histoplasmosis. Inhibition assays have been developed for antigen detection and offer at least one potential advantage, namely, reduced antibody requirements. We have developed an inhibition assay using the polyclonal antibody employed in our standard sandwich assay. Urine and serum specimens from patients with culture-proven histoplasmosis and controls were tested using both methods. The two methods had similar sensitivities for detection of antigen in urine (antibody sandwich = 92.5% versus inhibition = 87.5%, P = 0.500) and serum (82.5% versus 80.0%, P = 1. 000). With serum, the specificities of both methods were similar (antibody sandwich assay = 95.0% versus inhibition assay = 92.5%, P = 1.000), and with urine, the specificity of the antibody sandwich method was superior (97.5% versus 80.0%, P = 0.039). While the overall reproducibility of both methods was excellent (with urine, antibody sandwich assay intraclass correlation coefficient = 0.9975 and with serum = 0.9949; correlation coefficient of the inhibition assay with urine = 0.9736 and with serum = 0.9850), that of the inhibition method was only fair to poor for the controls: urine = -0. 0152, serum = 0.5595. Reproducibility was good for the controls using the sandwich method: urine = 0.7717, serum = 0.9470. Cross-reactivity was observed in specimens from patients infected with Blastomyces dermatitidis, Paracoccidioides brasiliensis, and Penicillium marneffei. In conclusion, the decreased specificity and inferior reproducibility with control specimens suggest that the inhibition assay has poorer precision toward the lower end of the detection range.  相似文献   

4.
A method was devised for enzyme labeling goat antibody to rabbit immunoglobulin G with beta-D-galactosidase (EC 3.2.1.23) using a heterobifunctional cross-linker, N-(gamma-maleimidobutyryloxy)-succinimide. Labeling of the purified antibody was by a continuous 2-step process and including a chromatographic purification procedure could be completed within one day. The partially purified anti-rabbit IgG was coated on Amino-Dylark cylinders, a new solid support, using glutaraldehyde as the coupling reagent. With enzyme-labeled antibody and the solid-phase anti-rabbit IgG, a sandwich enzyme immunoassay for rabbit IgG was developed with a lower limit of detection at 3.5 pM (0.1 ng/tube). The specificity of the assay was excellent and all 4 types of IgG tested showed 0.0001% or less cross-reactivity with rabbit IgG.  相似文献   

5.
Group B Streptococcus (GBS) is the most common cause of neonatal sepsis and meningitis. Infants at greatest risk to develop invasive disease are delivered to women colonized with GBS in their birth canals and lacking immunity to the colonizing serotype. We have investigated the sensitivity and specificity of a recently developed monoclonal antibody sandwich enzyme immunoassay for detection of GBS antigen. The sandwich enzyme immunoassay detected types II and III GBS at a concentration of 5 X 10(4) CFU/ml and types Ia and Ib GBS at 5 X 10(5) CFU/ml. No cross-reactions were noted when each of the GBS serotypes was reacted with antibodies of differing serotypes specificities. Type III GBS native antigen was detected at a concentration of 1 ng/ml. The sandwich enzyme assay is more sensitive than other methods currently in use for rapid detection of GBS and is serotype specific. This assay system should prove useful for the detection of GBS colonization during labor and for identification of neonates with invasive disease.  相似文献   

6.
A simple microfluidic immunoassay card was developed based on polystyrene (PS) substrate for the detection of horse IgG, an inexpensive model analyte using fluorescence microscope. The primary antibody was captured onto the PS based on covalent bonding via a self-assembled monolayer (SAM) of thiol to pattern the surface chemistry on a gold-coated PS. The immunosensor chip layers were fabricated from sheets by CO2 laser ablation. The functionalized PS surfaces after each step were characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). After the antibody–antigen interaction as a sandwich immunoassay with a fluorescein isothiocyanate (FITC)-conjugated secondary antibody, the intensity of fluorescence was measured on-chip to determine the concentration of the target analyte. The present immunosensor chip showed a linear response range for horse IgG between 1 μg/ml and 80 μg/ml (r = 0.971, n = 3). The detection limit was found to be 0.71 μg/ml. The developed microfluidic system can be extended for various applications including medical diagnostics, microarray detection and observing protein–protein interactions.  相似文献   

7.
A quantitative enzyme immunoassay (EIA) for specific antibody to neocarzinostatin (NCS) is described which uses enzyme-labeled anti-rabbit IgG antibody, solid-phase NCS and standard purified specific antibody to NCS. The dose of the standard was determined by sandwich EIA for rabbit IgG. The lower detection limit was 3 ng of the specific antibody per tube. The accuracy of the assay was excellent and a comparative study with the sandwich EIA for rabbit IgG showed good correlation. The antiserum to NCS of the highest titer was found to contain 0.6 mg and 40 mg per ml of specific antibody to NCS and of normal IgG, respectively. The accuracy of the assay results and the purity of the standard was established by 2 recovery tests for anti-NCS antibody.  相似文献   

8.
A direct (antiglobulin) solid-phase enzyme immunoassay for the detection of antibody to hepatitis B core antigen (anti-HBc) is described. The assay utilizes recombinant hepatitis B core antigen as the solid-phase 'capture' reagent and a mixture of monoclonal antibodies specific for human IgG and IgM conjugated to horseradish peroxidase as the 'detector' reagent. The direct assay demonstrated excellent sensitivity and specificity when compared with a commercially available competitive enzyme immunoassay. The direct assay format lends itself to a confirmatory assay for anti-HBc by addition of monoclonal anti-HBc to the reaction mixture. Feasibility of the confirmatory assay for anti-HBc was demonstrated using specimens reactive for anti-HBc as documented by both the direct and competitive assays.  相似文献   

9.
A chemiluminescent, microparticle-membrane capture immunoassay (CLIA/MMC) for the detection of antibody to hepatitis B core antigen (anti-HBc) is described. The assay utilizes recombinant hepatitis B core antigen coupled to carboxylated latex microparticles. Human polyclonal IgG anti-HBc labelled with acridinium competes with antibody in the sample for a limited number of binding sites on the solid phase. After a 40 min incubation at 40 degrees C, the reaction mixture is transferred to a glass fiber capture membrane and washed. A chemiluminescent signal is produced by addition of alkaline peroxide and is quantitated on a semi-automated reader as described. The CLIA/MMC assay was compared with standard EIA and RIA procedures (Corzyme and Corab, respectively, Abbott Laboratories, North Chicago, IL). Assay sensitivities were RIA greater than CLIA/MMC greater than EIA. A population of 200 normal blood donors showed nearly identical distributions with the CLIA/MMC and RIA (mean = 11% inhibition, SD = 13% for both), compared with the EIA (mean = 13% inhibition, SD = 15%). With a selected plasma population (n = 307), the CLIA/MMC immunoassay showed an excellent correlation (r = 0.94) with both the EIA and RIA procedures. Association of anti-HBc reactivity near assay cutoffs with antibody to hepatitis B surface antigen suggested relative specificity in the order RIA greater than CLIA/MMC greater than EIA. The CLIA/MMC procedure, which can be readily automated, provides a non-istopic alternative to current EIA testing with performance more nearly equivalent to RIA.  相似文献   

10.
Non-competitive enzyme immunoassay of human trypsin 1   总被引:1,自引:0,他引:1  
A sandwich enzyme immunoassay was developed for human pancreatic trypsin 1 using polystyrene balls coated with specific IgG as the first antibody and peroxidase-labeled IgG as the second antibody. The entire assay takes 6 h and the detection limit is 0.5 microgram/l. The assay can be performed on sera samples or on discs carrying dried blood spots. Good agreement was found with a radioimmunoassay kit. This simple assay could be widely applied to confirm the elevated immunoreactive serum trypsin described in newborn children with cystic fibrosis.  相似文献   

11.
本研究应用抗日本血吸虫可溶性虫卵抗原(SEA)的鸡卵黄免疫球蛋白(IgY)建立敏感、特异的检测循环抗原的双抗体夹心酶联免疫吸附试验( ELISA).用SEA皮下多点注射法免疫海蓝鸡,水稀释法制备IgY抗体,以辣根过氧化物酶标记纯化的IgY抗体(IgY-E)和兔抗IgG抗体(IgG-E)分别作为检测抗体,IgY抗体和兔抗...  相似文献   

12.
Indirect ELISA is widely used to detect specific antibodies but can suffer from high non-specific binding-particularly of IgG. The use of affinity-purified rabbit antibody-coated microtitre plates to bind antigen greatly increases sensitivity without a significant increase in non-specific binding of IgG. Capture, competitive and sandwich assay procedures gave comparable results for IgG antibodies; but only the sandwich assay was suitable for detection of IgE antibodies.  相似文献   

13.
Sequential plasma samples obtained from 16 individuals who seroconverted were tested for the presence of antibody to human immunodeficiency virus type 1 (HIV-1) by an antigen conjugate enzyme immunoassay (EIA) and a conventional antibody conjugate assay. In 11 of these individuals, the antigen conjugate assay detected antibody to HIV-1 2 to 11 days (mean, 5.5 days) earlier than the antibody conjugate assay. In 11 individuals, HIV-1 p24 antigen was detected a median of 6.5 days (range, 3 to 14 days) prior to positivity by the antigen conjugate EIA. Using class-specific probes, we determined the profiles of immunoglobulin M (IgM), IgG, and IgA antibodies for each individual and correlated these profiles with the EIA signals from both assays. In general, the appearance of IgM exhibited a peak at about 1 week postseroconversion, which was followed by gradually declining levels. Absorbance levels for IgG antibody, however, rose steadily and reached a plateau after 3 to 5 weeks. The levels of IgA were generally low and variable. In contrast to the progressive increase in EIA absorbance observed by the antibody conjugate assay, the antigen conjugate assay displayed a rapid early rise in absorbance which generally coincided with the transient expression of IgM antibody. The subsequent gradual increase coincided with rising levels of IgG. Because the configuration of the antigen conjugate EIA allows for an increased sensitivity for IgM compared with that for other classes of immunoglobulins, these results suggest that earlier detection of antibody to HIV-1 is due to the detection of IgM antibody during the early phase of seroconversion.  相似文献   

14.
Biomarkers play an important role in the detection at an early stage of pancreatic cancer. The aim of the present study was to optimize the conditions of antibody arrays for detecting Hippocalcin-like 1 (HPCAL1), phosphatidylethanolamine binding protein 1 (PEBP1), lectin galactoside-binding soluble 7 (LGALS7), and serpin peptidase inhibitor clade E member 2 (SERPINE2) as biomarkers for pancreatic cancer detection in a single assay and to investigate antibodies’ specificity and cross-reactivity. Capture antibodies against HPCAL1, PEBP1, LGALS7 and SERPINE2 were printed on nitrocellulose coated glass slides. HPCAL1, PEBP1, LGALS7 and SERPINE2 proteins with different concentrations were incubated with the capture antibodies at different temperatures for different time periods. Biotinylated detection antibodies recognizing a different epitope on the captured proteins and a secondary detection molecule (Streptavidin-PE) were used to detect fluorescent signals. The arrays showed the strongest signals when the concentration of the capture antibodies was at 500 μg/mL in PBST0.05 (PBS with 0.05% Tween-20), and the slides were incubated overnight at 4°C. The lowest protein concentration for detection was 2 ng/mL. Each antibody demonstrated high specificity to the corresponding antigen in detecting a mixture of 4 proteins without significant cross-reactivity. The fluorescence and biomarker concentration displayed a linear correlation. The antibody microarray system could be a useful tool for potential biomarker detection for pancreatic cancer.  相似文献   

15.
A dual, double antigen, time-resolved fluorescence immunoassay (DELFIA) for the simultaneous detection and quantitation of diphtheria (D) and tetanus (T) antibodies in sera has been developed. In the double antigen format one arm of the antibody binds to antigen coated microtitre wells and the other arm binds to labelled antigen to provide a fluorescent signal. This assay was found to be functionally specific for IgG antibodies and showed a good correlation with established toxin neutralization assays. Furthermore, the double antigen set-up was species independent, permitting the direct use of existing international references of animal origin to measure protective antibody levels in humans in international units (IU/ml). The detection limit corresponded to 0.0003 IU/ml with Eu3+-labelled toxoids and to 0.0035 IU/ml using Sm3+-labelled toxoids. The assay was fast with a high capacity making it a suitable method for serological surveillance studies.  相似文献   

16.
目的 制备一种高灵敏、高特异的免疫磁性微球(IMMS),为其在肿瘤早期诊断方面的应用提供借鉴.方法分别采用N-羟基琥珀酰亚胺3-(2-吡啶二硫代基丙酸酯)(SPDP)和1-乙基-3-(3-二甲基胺基丙基)碳化二亚胺盐酸盐(EDC)作为交联剂,将鼠抗人免疫球蛋白G(IgG)偶联于磁性微球上.采用激光共聚焦检测和125Ⅰ标记抗体考察偶联效果.比较交联剂、磁球微球上功能团、间隔臂、偶联条件及抗体用量等因素对偶联效果的影响.分别对不同浓度人源IgG进行吸附,确定最低检测值.结果 实验结果表明间隔臂对偶联效果影响不大.两种交联剂均可将抗体联接于磁性微球上,EDC为交联剂,工艺更为简便,室温条件下抗体结合效果优于4℃条件下.本实验所制备的IMMS对人源IgG的最低检测值为50pg/mL.结论 本实验以人源IgG为肿瘤标记模型,成功地制备了一种高灵敏、高特异免疫磁性微球,制备简便,成本低廉,为肿瘤早期诊断提供了借鉴.  相似文献   

17.
The immunoassay method in which 125I-labeled staphylococcal Protein A ([125I]PA) serves as a general tracer has been extended to include goat and sheep IgG antibodies. Goat and sheep IgG normally do not react significantly with PA. However, once IgG antibody is bound to immobilized antigen or hapten, binding of [125I]PA is enhanced markedly. Binding efficiencies of [125I]PA to immune complexed goat anti-human IgM, human IgE, methotrexate and sheep anti-IgE were determined and compared quantitatively to rabbit IgG with the corresponding specificity. Immunoassays were developed based on the inhibition of [125I]PA binding as a measure of antibody inhibition by fluid-phase homologous ligand. In terms of sensitivity and specificity, assays using goat and sheep antibodies were comparable to assays developed using rabbit IgG. Goat antibody to the monovalent hapten methotrexate behaved anomalously: for each concentration of IgG tested, there was an optimal amount of methotrexate beads that gave maximum binding of [125I]PA. In the other immune systems, for each antibody concentration maximum binding of tracer was a function only of the amount of immobilized antigen added. In contrast to the results obtained with solid-phase antigen, solutions containing antibody and amounts of antigen ranging from large antigen excess to antibody excess to antibody excess failed to react significantly with PA or [125I]PA.  相似文献   

18.
Potential factors influencing antigen detection in immunoassays for measuring rat or mouse aeroallergen (i.e., assay setup, antigen specificities, standard extracts used, and antigen decay) were investigated in a three-country study (the UK, The Netherlands, Sweden). An inhibition enzyme immunoassay (EIA) setup gave nominal rat urinary allergen (RUA) sample values seven times higher than a sandwich EIA setup utilizing identical antibodies and standards. In immunoblotting experiments, pooled patient serum and polyclonal rabbit antibodies partly detected different rat antigens; monoclonal antibody specificity could not be determined. Immunoblot detection of mouse urinary antigens (MUA) by the polyclonal rabbit antibodies from all laboratories was similar. In both the RUA and the MUA assays, urinary antigen standards were detected with similar potency, except purified Rat n 1, which was an inefficient inhibitor in the RUA RAST inhibition. In the sandwich EIA RUA assays, a rat room-dust extract was detected with 700800-fold less sensitivity than rat urine, whereas in the RAST RUA assay, dust inhibited equally with rat urine. Simulated decay did not decrease the potency of urinary antigen in any assay. Thus, assay setup and choice of detection antibodies strongly influence the nominal allergen levels. We recommend the use of standardized and characterized antibodies and standard extracts in sandwich EIAs to measure airborne rodent urinary allergens.  相似文献   

19.
为建立一种简单、快速、准确的铜绿假单胞菌检测方法,结合抗重组铜绿假单胞菌外膜蛋白单克隆抗体(mAb)、胶体金标记技术,采用双抗体夹心法,建立了检测铜绿假单胞菌的胶体金免疫层析法,并对该方法的特异性、灵敏度和稳定性进行了评价,对临床痰标本进行了检测。结果显示,该胶体金免疫层析法能在3~15min内完成检测,方法的特异性高、稳定性强,检测灵敏度能达到105CFU/mL。与传统细菌培养方法相比,胶体金免疫层析法的相对灵敏度和特异性分别是80%和90.6%,两种方法的总符合率为86%。结论:利用抗铜绿假单胞菌单克隆抗体建立的胶体金免疫层析法,适合现场快速、特异检测铜绿假单胞菌。  相似文献   

20.
The aim of the present study was to evaluate the efficiency of 14.5 kDa-Fasciola gigantica fatty acid binding protein (FABP) as a diagnostic antigen for human fascioliasis. 14.5 kDa FABP was isolated from the crude extract of adult F. gigantica worms by ion exchange chromatography followed by gel filtration chromatography and then analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis under reducing condition. Anti-FABP IgG polyclonal antibody (pAb) was generated in rabbits and purified by using sequential use of ammonium sulfate, caprylic acid, and then ion exchange chromatography. Conjugation of purified rabbit anti-FABP IgG with horse reddish peroxidase (HRP) was conducted and used in detecting the coproantigen in the stool and the circulating Fasciola antigen (CA) in the sera of Fasciola-infected patients using sandwich enzyme-linked immunosorbent assay (ELISA). The sensitivities of sandwich ELISA test were 96.43% and 94.74%, while the test specificities were 94.87% and 84.62% for the detection of coproantigen and CA, respectively. The parasitological diagnosis using the Kato–Katz technique revealed 64.29% sensitivity with 100% specificity. The diagnostic efficacy of sandwich ELISA was 95.52% for coproantigen and 87.93% for CA detection. In contrast, the diagnostic efficacy of Kato–Katz technique was 85.07%. It was concluded that 14.5 kDa FABP represented a valuable antigen for the immunodiagnosis of human fascioliasis using sandwich ELISA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号