The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography.  相似文献   

2.
Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.  相似文献   

3.
Objective. To compare four imaging methods in the evaluation of the postoperative meniscus: conventional arthrography, conventional MR imaging, MR arthrography with iodinated contrast material, and MR arthrography with gadolinium-based contrast material. Design and patients. Thirty-three patients referred for knee MR examinations with a history of meniscal surgery were studied prospectively. At the first patient visit, conventional MR examination was followed by an MR arthrogram with gadolinium-based contrast material. At the second visit, a conventional arthrogram with iodinated contrast material was followed immediately by an MR examination. Imaging examinations were interpreted by a masked reader, and then compared with the results of repeat arthroscopic surgery in 12 patients. Results. The correct evaluation of the status of postoperative menisci was allowed in 12 of 13 patients (92%) by MR arthrography using gadolinium-based contrast agent, 10 of 13 patients (77%) by conventional MR examination, 9 of 12 patients (75%) by MR arthrography, and 7 of 12 patients (58%) by conventional arthrography. Conclusion. Intra-articular fluid is advantageous in the evaluation of patients with a suspected meniscal retear. MR arthrography with gadolinium-based contrast material is the most accurate imaging method for the diagnosis of meniscal retears. Received: 7 April 1999 Revision requested: 26 May 1999 Revision received: 17 June 1999 Accepted: 18 June 1999  相似文献   

4.
K-edge energy subtraction radiography is a method for detecting the presence of iodinated contrast material by subtracting two digital radiographs produced by X-ray beams with energies above and below the iodine K edge. We performed a feasibility study on the application of K-edge energy digital subtraction arthrography (KEDSA) to painful hip prostheses. During arthrography, loosening of the prosthesis is implied if contrast material is seen dissecting around the prosthesis, an often difficult detection task because of adjacent prosthesis metal or cement. In conventional arthrography a preliminary mask image is thus used from which films obtained after injection of iodinated contrast material are subtracted. Movement by the patient during this process may preclude subsequent subtraction. With KEDSA, since multiple image pairs may be obtained after the injection of contrast material, the problem of patient motion is virtually eliminated. A conventional X-ray tube operating between 55 and 65 kVp was alternately filtered by iodine and cerium filters to produce the KEDSA images. The apparatus was capable of producing a subtracted image within 3 sec. The technique was applied to phantoms and to six patients immediately after hip arthrography that had been positive for prosthesis loosening. Although of lower spatial resolution, the KEDSA images were, in all cases, positive for loosening in a pattern consistent with the conventional arthrographic images. KEDSA was shown to be successful in detecting extraarticular contrast material. During a single study, subtraction in various imaging planes as well as postexercise subtraction imaging can be accomplished-techniques not heretofore possible in routine subtraction arthrography.  相似文献   

5.
The recent popularity of ingrowth or uncemented hip arthroplasties has presented problems in the radiographic diagnosis of loosening because there is no longer a cement interface in which lucencies may be seen. We evaluated a combination of positive contrast and nuclear arthrography to see whether these studies could accurately detect loosening of uncemented femoral components of hip prostheses. We performed routine contrast and nuclear arthrography in 21 patients with ingrowth total hip arthroplasties or bipolar endoprostheses. The results were surgically confirmed in 12 patients. The contrast arthrogram was true positive in 5 and false negative in 5. There were no false positives and 2 true negatives. The nuclear arthrogram was true positive in 7 patients, false negative in 3, and true negative in 2. Taken together, there was only 1 patient in whom both contrast and nuclear arthrography were false negative, and there were no false positives. Thus, when either contrast or nuclear arthrography is positive, the sensitivity of the combined procedures is 90%; when both studies are negative, the specificity is 100%. The combination of contrast and nuclear arthrography is an accurate method of determining loosening of the femoral component of an uncemented hip arthroplasty or bipolar endoprosthesis in the patient with postoperative hip pain.  相似文献   

6.
Arthroscintigraphic evaluation of the painful total hip prosthesis   总被引:1,自引:0,他引:1  
Arthroscintigraphy was performed in 19 patients with a painful total hip prosthesis by injecting both Tc-99m sulfur colloid and iodinated radiographic contrast material intra-articularly. Scintigraphic and radiographic results correlated exactly in 15 patients, with one false-negative scintigram, one false-positive scintigram, and one false-negative arthrogram. One patient was evaluated by scintigraphy alone. Although arthroscintigraphy is potentially more sensitive than conventional arthrography in the detection of femoral component loosening, acetabular component loosening cannot be evaluated by scintigraphy alone. A combination of scintigraphy and conventional arthrography appears to be the most accurate imaging method in the evaluation of hip prosthesis loosening.  相似文献   

7.
Previous reports have stressed the value of hip arthrography primarily in determining the presence of loosening of the total hip prosthesis. Although loosening is a common complication and frequently associated with infection, other complications producing a painful hip prosthesis exist and are demonstrable by arthrography. Since the etiologies of these are as diversely different as the treatment, the hip arthrogram is advocated as an integral part of the diagnostic approach to the patient with a painful hip prosthesis in order to assess the specific complication and determine the therapeutic approach.  相似文献   

8.
We report three cases of intra-articular infection which followed injection for magnetic resonance arthrography. In an effort to reduce the risk of arthrogram related infection, representatives from radiology, infectious disease medicine, and microbiology departments convened to analyze the contributing factors. The proposed source was oral contamination from barium swallow studies which preceded the arthrogram injections in the same room. We propose safety measures to reduce incidence of arthrogram related infections.  相似文献   

9.
Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. Digital subtraction arthrography of the femoral component demonstrated a 96% sensitivity and 100% specificity for the diagnosis of component loosening. Sensitivity and specificity for acetabular component loosening were 83% and 80%, respectively. Plain film subtraction of the femoral component demonstrated a 79% sensitivity and 100% specificity; the sensitivity and specificity for the acetabular component were 75% and 80%, respectively. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P<0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses.  相似文献   

10.
Nuclear medicine has proven to have a valuable role in the evaluation of osseous metallic implants, particularly with joint prostheses, but can assist with evaluation of other appliances as well. The nuclear arthrogram has become an invaluable adjunct to simultaneously performed radiographic contrast arthrography. This application has been best evaluated in what is one of the most common of orthopedic prosthesis problems, namely, loosening of total hip prostheses. Experience indicates that both sensitivity and specificity of loosening of the femoral component can be increased to over 90% through combined use of nuclear with radiographic contrast arthrography. Furthermore the combination of routine skeletal scintimaging with the nuclear arthrogram adds a significant dimension to precise localizing of the nuclear arthrographics agent In-111 chloride. Nuclear medicine also plays an important role in further evaluating the presence of infection associated with metallic implants with In-111 WBC preparations being superior to Ga-67 as the radiopharmaceutical tracer. Infection has been detected with a sensitivity of 73% and a specificity of 93% in our series using combined In-111 WBC and simultaneous skeletal imaging with conventional Tc-99m MDP. Acute infections are more readily identifiable than chronic in association with prostheses.  相似文献   

11.

Purpose

This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy.

Materials and methods

One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy.

Results

Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear.

Conclusions

The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely.  相似文献   

12.
A new technique using double contrast after digital subtraction wrist arthrography is presented. Results of the double contrast wrist arthrograms were essential to the diagnosis, confirmed the diagnosis, or salvaged an otherwise poor or nondiagnostic examination. It was found that intra-articular injection of air augments the information obtained during postarthrogram active motion studies under fluoroscopy. Double contrast wrist arthrography has proved valuable when the standard contrast arthrogram fails to yield diagnostic information.  相似文献   

13.
Radiological evaluation of painful total hip replacement   总被引:3,自引:0,他引:3  
Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated.  相似文献   

14.
Diagnosis of popliteal cyst: double-contrast arthrography and sonography   总被引:5,自引:0,他引:5  
One hundred consecutive patients who had trauma to the knee were examined by sonography and double-contrast arthrography to evaluate the presence or absence of popliteal cyst. In 58 cases both tests were negative, while in 15 both were positive. Each of those 15 patients had pain and/or a palpable mass behind the knee. In 27 remaining patients the arthrogram demonstrated a popliteal cyst that was not detected on the sonogram. None of the 27 patients complained of pain in the popliteal fossa or had a palpable mass in the area. The sonographic findings, however, showed good correlation with these clinical symptoms. This paper attempts to analyze these discrepancies and to evaluate the advantages and disadvantages of each method.  相似文献   

15.
Objective. To investigate the merits of arthrography after supination trauma of the ankle. Design and patients. In a group of 160 consecutive patients operative exploration was performed in cases where arthrography and/or a delayed physical examination showed positive findings. In all patients arthrography was performed within 48 h after trauma. To determine interobserver agreement, all arthrograms were independently evaluated by two radiologists, both ignorant of the first assessment. Results. The prevalence of an ankle ligament lesion was found to be 76%. Of the 122 patients with a rupture of one or more ankle ligaments, 52% had an isolated anterior talofibular ligament lesion, 3% had an isolated calcaneofibular ligament lesion, and 45% had combined lesions. The site of the lesion was predominantly intraligamentous. In the determination of the presence or absence of an ankle ligament lesion, the specificity and sensitivity of the ankle arthrogram were 71% and 96% respectively. Interobserver agreement on the arthrogram was very good (κ 0.9). In 1% of patients a clear diagnosis was not possible by means of arthrography. Conclusion. Arthrography provides information of high diagnostic quality with excellent interobserver agreement and therefore remains the gold standard for early diagnosis (within 48 h) of a lateral ankle ligament rupture.  相似文献   

16.
Huang GS  Lee CH  Lee HS  Chen CY 《European radiology》2005,15(12):2411-2414
Snapping of the elbow joint can cause pain. We report a case of painful snapping elbow produced by an interposed meniscus in the radiohumeral joint in a 20-year-old man. The MR arthrogram demonstrated a meniscus-like tissue interposed between the radial head and humeral capitellum. The MR-arthrographic findings were well correlated with surgical findings. The location and appearance of the meniscus-like tissue was similar to that of meniscus in the knee joint. Histologic findings of the excised meniscus-like tissue showed a typical presentation of fibrocartilage. A meniscus may exist in the elbow joint and can be a rare cause of painful snapping elbow. MR arthrography is helpful for identifying the snapping tissue in the elbow joint.  相似文献   

17.
Objective. The objective of this clinical study was to define the diagnostic value of plain radiography, digital subtraction arthrography and two-phase bone scintigraphy in patients with clinically loose or infected hip prostheses. Design. Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Results. Digital subtraction arthrography was best (P<0.001) for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs (P=0.24) and scintigraphy (P=0.27). Digital subtraction arthrography was also the most important modality for predicting a loose femoral component (P=0.001), while the plain radiograph was of significant (P=0.04) additional value and scintigraphy was of no additional value (P=0.13) on multivariate analysis. Conclusion. Digital subtraction arthrography gives the best results in the prediction of loosening of acetabular and femoral components. Plain radiographs give additional information on loosening of the femoral component, but scintigraphy offers no additional advantage.  相似文献   

18.
间接法MRI膝关节造影对半月板撕裂的评价   总被引:7,自引:0,他引:7  
目的 评价间接法MRI膝关节造影对半月板撕裂的诊断价值。方法 回顾性分析 75例常规MRI膝关节扫描和 6 4例间接法MRI膝关节造影病例资料 ,以膝关节镜检查为诊断金标准 ,对比分析常规MRI和间接法MRI膝关节造影对半月板撕裂的诊断。结果 间接法MRI膝关节造影对内侧半月板撕裂的诊断敏感性、特异性、准确性、阳性预测值和阴性预测值分别为 72 %,10 0 %,89.1%,10 0 %和 84.8%;对外侧半月板撕裂分别为 83.8%,90 .9%,87.5 %,89.6 %和 85 .7%。与常规MRI比较 ,间接法MRI膝关节造影对内外侧半月板撕裂的诊断能力都没有统计学差异。结论 尽管间接法MRI膝关节造影对内外侧半月板撕裂诊断价值很高 ,但与常规MRI比较没有统计学差异。  相似文献   

19.
Digital arthrography was accomplished in 16 patients who had painful prostheses. In each instance, resulting arthrographic abnormalities were compared with those apparent on subsequent overhead radiographs. Results indicate the potential value of the digital technique in this clinical setting. The examination is easy to perform and rapid, and allows the examiner to view the changing images in the subtraction mode. Image manipulation and enhancement are also possible.  相似文献   

20.
Radionuclide arthrography is becoming increasingly useful in the evaluation of femoral component loosening in patients with a painful total hip prosthesis. Additional potential advantages of radionuclide arthrography include detection of abnormal communications with the hip, such as bursae, abscess cavities, and fistulas. A case of cutaneous fistula communicating with the hip in a patient with loosening and infection of the femoral component of the total hip prosthesis that is clearly demonstrated by radionuclide arthrography is presented.  相似文献   