首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This ex vivo study aimed to measure the performance of an electronic apex locator (EAL) in the presence of sodium hypochlorite irrigants with different concentrations. Two EALs (Root ZX Mini and Locapex 6) were used to locate the apical foramen in 10 extracted single-rooted teeth in the presence of 0.5%, 2.5% and 5% sodium hypochlorite. Visual working lengths were also determined using #10 K-file under a microscope before the electronic measurements were made. The performance of both EALs was compared for the electronic working lengths determined under the different concentrations of sodium hypochlorite. A multiple-way ANOVA and PLSD Fisher’s test with an α risk fixed at 5% were conducted. There were no statistical differences in the working lengths determined by both EALs between the three groups with different concentrations of sodium hypochlorite and their visual control measurements. When a ± 0.5 mm margin was applied, the Root ZX Mini and the Locapex 6 presented 88% and 83% accuracy, respectively. Sodium hypochlorite concentration in irrigants does not affect the accuracy and reliability of either the Root ZX Mini or the Locapex 6. Electronic apex locators are reliable with any concentration of sodium hypochlorite irrigants.  相似文献   

2.
The aim was to evaluate the canal straightening and the amount of apically extruded debris associated with five rotary nickel-titanium when preparing curved root canals. A total of 100 root canals in extracted human teeth (angles of curvatures 20°–30°; radii 5.9–13.5 mm) were divided into five groups (n = 20/group). The groups were balanced with respect to the angle and the radius of canal curvature. The root canals were prepared using conventional austenite 55-NiTi alloy instruments F360, F6 SkyTaper (both Komet, Lemgo, Germany), and the heat-treated NiTi Jizai, Silk-Complex and Silk-Standard instruments (all Mani, Tochigi, Japan) to an apical size 25. The amount of extruded debris was assessed with a micro balance. Statistical analysis was performed using Kruskal–Wallis test with Bonferroni correction at a significance level of p < 0.05. During canal preparation, neither instrument fractures nor procedural preparation errors were noticed. Regarding canal straightening, the use of Jizai instruments resulted in the significantly lowest straightening (p < 0.05), while no significant differences were obtained between all other groups (p > 0.05). Regarding the amount of apically extruded debris, no significant differences between all groups were obtained (p > 0.05). Within the limitations of this study, all instruments performed well, and especially the Jizai instruments showed an excellent shaping ability.  相似文献   

3.
The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (n = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (n = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (p > 0.05), but demonstrated significantly different resistance to cyclic fatigue (p < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.  相似文献   

4.
目的探讨应用牙再植术治疗根尖部根管内折断器械的临床效果。方法对12例根尖部根管内折断器械的病例采用牙再植术进行治疗。结果 12例中8例取得成功,4例失败。结论在严格把握适应证的前提下,牙再植术治疗根尖部根管内折断器械也是一种有效方法,微创、快速的操作、比较稳定的固定有利于治疗的成功。  相似文献   

5.
6.
7.
Spinal canal stenosis is a dynamic phenomenon that becomes apparent during spinal loading. Current diagnostic procedures have considerable short comings in diagnosing the disease to full extend, as they are performed in supine situation. Upright MRI imaging might overcome this diagnostic gap.This study investigated the lumbar neuroforamenal diameter, spinal canal diameter, vertebral body translation, and vertebral body angles in 3 different body positions using upright MRI imaging.Fifteen subjects were enrolled in this study. A dynamic MRI in 3 different body positions (at 0° supine, 80° upright, and 80° upright + hyperlordosis posture) was taken using a 0.25 T open-configuration scanner equipped with a rotatable examination bed allowing a true standing MRI.The mean diameter of the neuroforamen at L5/S1 in 0° position was 8.4 mm on the right and 8.8 mm on the left, in 80° position 7.3 mm on the right and 7.2 mm on the left, and in 80° position with hyperlordosis 6.6 mm (P < 0.05) on the right and 6.1 mm on the left (P < 0.001).The mean area of the neuroforamen at L5/S1 in 0° position was 103.5 mm2 on the right and 105.0 mm2 on the left, in 80° position 92.5 mm2 on the right and 94.8 mm2 on the left, and in 80° position with hyperlordosis 81.9 mm2 on the right and 90.2 mm2 on the left.The mean volume of the spinal canal at the L5/S1 level in 0° position was 9770 mm3, in 80° position 10600 mm3, and in 80° position with hyperlordosis 9414 mm3.The mean intervertebral translation at level L5/S1 was 8.3 mm in 0° position, 9.9 mm in 80° position, and 10.1 mm in the 80° position with hyperlordosis.The lordosis angle at level L5/S1 was 49.4° in 0° position, 55.8° in 80° position, and 64.7 mm in the 80° position with hyperlordosis.Spinal canal stenosis is subject to a dynamic process, that can be displayed in upright MRI imaging. The range of anomalies is clinically relevant and dynamic positioning of the patient during MRI can provide essential diagnostic information which are not attainable with other methods.  相似文献   

8.
Chemomechanical preparation of the root canal system is considered to be the most important part of root canal treatment, including both mechanical removal of tissue remnants and dentine chips, and chemical elimination of biofilm and microorganisms. A number of different solutions and agitation techniques have been proposed for that purpose. It was the aim of the present study to investigate whether root canal cleanliness can be improved by using a hydroxyapatite nanoparticle-containing solution with and without sonic or ultrasonic agitation. Seventy-four single-rooted teeth were divided into four experimental groups (n = 15) and two control groups (n = 7). All teeth were split longitudinally and a groove and three holes were cut into the root canal wall and filled with dentinal debris. Final irrigation was performed using sodium hypochlorite or a hydroxyapatite nanoparticle-containing solution (Vector polish) activated with a sonically or an ultrasonically driven endodontic file. Two calibrated investigators rated the remaining debris using a four-score scale. The results were analyzed using a non-parametric test with α < 0.05. Sonic and ultrasonic irrigation with sodium hypochlorite cleaned the grooves and holes well from debris. The hydroxyapatite nanoparticles activated by a sonic file cleaned grooves and holes equally well. Ultrasonically activated nanoparticles performance was clearly inferior. The syringe control-group left large amounts of debris in grooves and holes. The use of the hydroxyapatite nanoparticles used in this study did not improve removal of debris.  相似文献   

9.
We aimed to compare the effectiveness and safety of hepatic resection and radiofrequency ablation (RFA) for small hepatocellular carcinomas (HCCs) less than 5 cm in diameter.A total of 289 patients were diagnosed with a small HCC (a single tumor no larger than 5 cm). Among these patients, 133 underwent hepatic resection, and 156 received RFA. Demographic data, intraoperative data, post-operative recovery data, and the baseline characteristics of the 2 groups of patients were compared. The incidence of post-operative complications; 1-, 3-, and 5-year survival rates; and tumor recurrence were determined.No statistically significant differences in the baseline characteristics were noted between the 2 groups. By contrast, operation time (P = 0.003), intraoperative blood loss (P = 0.000), and the length of post-operative hospital stay (P = 0.000) were significantly lower in the RFA group compared with the surgical resection group. The 2 groups displayed similar post-operative complication rates (12% or 16/133 in the liver resection group vs. 8.3% or 13/156 in the RFA group, P = 0.395). The 1-, 3-, and 5-year overall survival rates of the patients in the liver resection group were 88.7%, 78.2%, and 66.2%, respectively, whereas the rates in the RFA group were 90.4%, 76.3%, and 66.0%, respectively (P = 0.722). The 1-, 3-, and 5-year tumor-free survival rates of patients in the resection group were 87.2%, 69.9%, and 58.6%, respectively, whereas the rates in the RFA group were 85.9%, 66.0%, and 54.5%, respectively (P = 0.327). In addition, among HCC patients receiving RFA, patients with tumors no greater than 3 cm in diameter exhibited no significant differences regarding overall survival and tumor-free survival rates compared with patients with tumors 3 to 5 cm in diameter (all P > 0.05).RFA is an effective and safe treatment option for small HCCs and may be a preferred choice for HCC patients with small lesions.  相似文献   

10.
Gallbladder polyps (GBPs), especially GBPs ≥5 mm in diameter, are clinically important because they can progress to gallbladder cancer. The known modifiable risk factors for GBP are obesity, metabolic syndrome, and dyslipidemia; however, there is limited evidence regarding specific modifiable risk factors for GBPs ≥5 mm in diameter. Therefore, this study is aimed to investigate the existence of modifiable risk factors affecting the prevalence of GBPs and GBPs ≥5 mm in diameter in a Korean population.A total of 10,119 subjects who visited a single health-screening center at Jeju National University Hospital between January 2009 and December 2019 was included in this study. Binary logistic analyses were performed to identify risk factors affecting the prevalence of GBPs and GBPs ≥5 mm in diameter.The overall prevalence of GBPs and GBPs ≥5 mm in diameter were 9.0% and 4.1%, respectively. Multivariable analysis identified male gender as an independent risk factor affecting the prevalence of GBPs. Moreover, multivariable analysis revealed age and high-density lipoprotein cholesterol levels as independent risk factors for GBPs ≥5 mm in diameter.This study showed that gender was a risk factor affecting the prevalence of GBPs and that age and high-density lipoprotein-cholesterol levels were risk factors for the presence of GBPs ≥5 mm in diameter. High-density lipoprotein cholesterol levels could be a modifiable risk factor affecting the prevalence of large-diameter GBPs.  相似文献   

11.
Recent biomechanics studies have revealed distinct kinematic behavior of different lumbar segments. The mechanisms behind these segment-specific biomechanical features are unknown. This study investigated the in vivo geometric characteristics of human lumbar intervertebral discs.Magnetic resonance images of the lumbar spine of 41 young Chinese individuals were acquired. Disc geometry in the sagittal plane was measured for each subject, including the dimensions of the discs, nucleus pulposus (NP), and annulus fibrosus (AF). Segmental lordosis was also measured using the Cobb method.In general, the disc length increased from upper to lower lumbar levels, except that the L4/5 and L5/S1 discs had similar lengths. The L4/5 NP had a height of 8.6 ± 1.3 mm, which was significantly higher than all other levels (P < 0.05). The L5/S1 NP had a length of 21.6 ± 3.1 mm, which was significantly longer than all other levels (P < 0.05). At L4/5, the NP occupied 64.0% of the disc length, which was significantly less than the NP of the L5/S1 segment (72.4%) (P < 0.05). The anterior AF occupied 20.5% of the L4/5 disc length, which was significantly greater than that of the posterior AF (15.6%) (P < 0.05). At the L5/S1 segment, the anterior and posterior AFs were similar in length (14.1% and 13.6% of the disc, respectively). The height to length (H/L) ratio of the L4/5 NP was 0.45 ± 0.06, which was significantly greater than all other segments (P < 0.05). There was no correlation between the NP H/L ratio and lordosis.Although the lengths of the lower lumbar discs were similar, the geometry of the AF and NP showed segment-dependent properties. These data may provide insight into the understanding of segment-specific biomechanics in the lower lumbar spine. The data could also provide baseline knowledge for the development of segment-specific surgical treatments of lumbar diseases.  相似文献   

12.
It is necessary to assess coronal Cobb angle in the diagnosis and treatment of patients with adult degenerative scoliosis (ADS). But as most ADS patients are elderly patients who are difficult or unable to stand upright without assistance, it is difficult to obtain standing posteroanterior X-ray radiographs. Whether it is possible to use Cobb angle obtained on a supine posteroanterior X-ray radiograph to predict Cobb angle in a standing position remains unanswered.To study the correlation between X-ray plain radiographic parameters obtained from the supine position and those obtained from the standing position in ADS patients.Medical records and radiological information were obtained from ADS patients prospectively. Posteroanterior X-ray views of the spine were taken in both standing and supine positions simultaneously in the same ADS patients to record information about the position of the apical and end vertebrae in the coronal position and measure Cobb angle and rotation degree of the apical vertebra. Correlation and linear regression were used to analyze the correlation between the Cobb angle and the rotation degree of the apical vertebra on the X-ray plain radiographs obtained from the standing and supine positions.Of 94 ADS patients who met the inclusion criteria, 14 (15%) patients were male and 80 (85%) patients were female who ranged in age from 41 to 92 years with a mean of 67 years. The mean Cobb angle on the supine X-ray radiographs was 21 ± 10° versus 26 ± 12° on the standing X-ray radiographs, the difference being statistically significant (P < 0.01). The rotation angle of the apical vertebra in the supine and standing positions was 1.8 ± 0.7 and 1.9 ± 0.7, respectively, the difference being statistically significant (P < 0.05). Correlation analysis showed a strong correlation in Cobb angle between the supine and standing X-ray plain radiographs (r = 0.92, P < 0.01). The correlation coefficient of the rotation of the apical vertebra was rho = 0.81 (P < 0.01). The equation of predicting the standing Cobb angle from the supine position as shown by the linear regression analysis is as follows: standing Cobb angle = 1.15 × supine Cobb angle + 1.53 (R2 = 0.838). There was no significant difference between supine Cobb angle +5° and standing Cobb angle (P = 0.413).The posteroanterior X-ray plain radiograph of the spine can provide information similar to that obtained from the standing coronary position in ADS patients, including the position of the apical and end vertebrae. There was a strong correlation between the Cobb angle and the degree of rotation of the apical vertebra on the X-ray radiographs obtained from the supine and standing positions, indicating that the supine Cobb angle can be used to predict the Cobb angle on the standing X-ray radiograph. The supine X-ray radiograph can replace the standing posteroanterior radiograph in terms of the coronal parameters.  相似文献   

13.
(1) Aim: This study aims to analyze the in vitro infiltration of a silicate root canal sealer into dentinal tubules after using different endodontic irrigating solutions. (2) Methods: Twenty-nine teeth with single roots were separated into three groups according to the final irrigation protocol: G1 n = 10) = 17% EDTA (ethylenediaminetetraacetic acid) + 3.0% sodium hypochlorite (NaOCl), G2 (n = 10) = 17% EDTA + 2.0% chlorhexidine and G3 (Control group, n = 9) = 17% EDTA + saline solution. Root canals were filled using cold lateral compaction technique with MTA Fillapex sealer and gutta-percha. The sealer was labeled with rhodamine B. The teeth were segmented at the middle and third apical sections, which were visualized using 10× confocal laser microscopy to determine the sealer penetration percentage. (3) Results: In the apical section, no statistically significant differences were found between the groups regarding sealer penetration. In the middle section, Group 1 obtained the highest percentage, and Group 2 the lowest (p = 0.004). Group 1 also presented statistically significant differences in the Control Group (p = 0.031) and had close sealer penetration values. Meanwhile, the Control Group (p = 0.023) and Group 2 (p = 0.029) revealed a significant decrease of sealer penetration between the apical and middle sections. (4) Conclusion: The obtained results support that final irrigation with NaOCl promoted similar sealer penetration in the apical and middle sections. On the other hand, a significant decrease in the sealer penetration of the middle section was observed for the chlorhexidine and saline groups. Compared to other irrigant solutions, NaOCl promotes more uniform sealer penetration, which can correlate with better sealing and, consequently, higher endodontic treatment success.  相似文献   

14.
Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to investigate the influence of the angle of access on the torsional resistance of endodontic instruments. One hundred and eighty instruments were selected: 90 F-One Blue 25/04 and 90 HeroShaper 25/04 instruments. Three subgroups (n = 30) for each instrument type (A and B) were established according to the angle of insertion of the instruments inside the artificial canal (0°, 10° and 20°). The tests were performed using a custom-made device consisting of the following: a motor that can record torque values of 0.1 s; interchangeable stainless-steel canals with different curvature (0°, 10° and 20°) that allow the instrument’s angulated insertion and keep it flexed during testing procedures; and a vise used to secure the instrument at 3 mm from the tip. Torque limit was set to 5.5 Ncm, and each instrument was rotated at 500 rpm until fracture occurred. Torque to fracture (TtF) was registered by the endodontic motor, and the fragment length (FL) was measured with a digital caliper. Fractographic analysis was performed using a scanning electron microscopy (SEM) evaluation to confirm the cause of failure. TtF values and fragment length (FL) values were statistically analyzed using one-way analysis of variance (ANOVA) test and the Bonferroni correction for multiple comparisons across the groups with significance set to a 95% confidence level. Regarding the F-One Blue instruments, the results showed a higher TtF for group A3 (20°) than for group A1 (0°) and group A2 (10°), with a statistically significant difference between group A3 and the other two groups (p < 0.05), whereas no statistically significant difference was found between group A1 and group A2 (p > 0.05). Regarding the HeroShaper instrument, the results showed the highest TtF for group B3, with a statistically significant difference between the three subgroups B1, B2 and B3 (p < 0.05). The results showed that the torsional resistance increases as the angle of instrument access increases with a varying intensity, according to the crystallographic phase of the instrument selected.  相似文献   

15.
As the use of nickel-titanium (NiTi) file systems for root canal therapy has become popular; hence, knowledge and understanding of the characteristics of NiTi files is essential for dentists. Unintended sudden fracture can occur during root canal shaping, and it is important to understand the conditions that may cause instrument fractures. Torque is defined as the force required to rotate the NiTi file and can be considered of as a parameter for the stress generated. The endodontic engine maintains a constant rotational speed by adjusting torque regardless of the root canal conditions. The process of root canal shaping by rotary instruments is a series of actions that requires torque and generates stress to both the teeth and the NiTi instruments. The generated stress may induce the strain accumulation on NiTi instrument and the canal wall and lead to the development of microcrack in the instrument and dentinal wall. Therefore, understanding of torque and stress generated is important to prevent the fractures to the instrument and the teeth. This stress has been measured using various experimental approaches, including microcrack observation by using a microscope or computed tomography, attaching strain gauges to the teeth, and finite element analysis. This review focuses on the stress generated to the teeth and the instrument during instrumentation under various experimental conditions. The factors related to torque generation are also discussed.  相似文献   

16.
To evaluate the value of angiographic factors in predicting failure of both venous and arterial coronary artery bypass graft.We retrieved from our angiographic database 148 patients who underwent venous and/or arterial CABG and for whom a control coronary angiography at more than 1 month after surgery was available. Pre-CABG and follow-up angiographies were analyzed in order to evaluate diameter stenosis (DS,%), stenosis length (mm), Bogaty score (extent index), Sullivan score, and Gensini score for the extent of coronary artery disease, and Jeopardy Duke score for the extent of myocardial area supplied by an artery.Thirty-nine patients (26%) experienced graft failure at follow-up (mean follow-up 11.3 ± 4.6 months). Patients with venous graft failure [26 (20%)] had significantly smaller DS (P = 0.013), shorter stenosis length (P = 0.01), and lower extent index (P = 0.015), Sullivan score (P = 0.013), Gensini score (P = 0.04) as compared with those without venous graft failure. Patients with arterial graft failure [13 (11%)] had significantly lower DS (P = 0.008), shorter stenosis length (P = 0.001), and lower extent index (P = 0.03) and Sullivan score (P = 0.023) as compared with those without arterial graft failure.Venous and arterial graft failure are associated with less severe stenosis and less extensive atherosclerosis of the grafted vessel.  相似文献   

17.
Instrument failure during root canal preparation is still a concern among endodontists. However, it remains unclear whether the use of more martensitic alloys or the cross-sectional design parameters (i.e., core mass) significantly improve fracture resistance. The aim of the study was to evaluate the impact of core mass and alloy on dynamic cyclic fatigue resistance of nickel-titanium endodontic instruments in matching artificial canals at body temperature. Two groups were tested. (A) taper 0.04: F360 (Komet, Lemgo, Germany), Twisted file (Sybron Endo, Glendora, CA, USA) (=TF), JIZAI (Mani, Tochigi, Japan) (=J_04) (all size #25) and the variable tapered TruNatomy (Dentsply, Ballaigues, Switzerland) (size #26) (=TN). (B) size #25; taper 0.06: (Mtwo (VDW, Munich, Germany), JIZAI (Mani) (=J_06), and variable tapered Hyflex EDM OneFile (Coltene Whaledent, Altstätten, Switzerland) (=HF). Time, number of cycles to fracture (NCF), and number and length of fractured fragments were recorded and statistically analysed using ANOVA Student-Newman-Keuls, Kruskal–Wallis or Chi-square test (significance level = 0.05). (A) TN showed the significantly shortest time until fracture, followed by TF, F360 and J_04 which also differed significantly, while NCF showed the following order: F360 < TN < TF < J_04 (p < 0.05). Only one J_04 but all instruments of the other groups fractured within the test-limit of 10 min. (B) Mtwo was significantly inferior concerning time until fracture and NCF, compared to J_06 and HF (p < 0.05), which did not differ significantly (p > 0.05). While all Mtwo instruments fractured, only four instruments failed in the other groups (p < 0.05). Within the limitations of this study, alloy and cross-sectional design (i.e., core mass) were critical factors regarding instrument failure, but none of these factors could be determined as a main parameter for increased or decreased time, and cycles to fracture. Rather, it seemed to be the interaction of multiple factors (e.g., longitudinal and cross-sectional design, alloy, and rotational speed) that was responsible for differences in the time and cycles to fracture. Nonetheless, all instruments had lifetimes that allow safe clinical use. However, the superiority or inferiority of an instrument with regard to cyclic fatigue based on laboratory results—even when identical trajectories are guaranteed—may be considered questionable, as the characteristics and design parameters of the instruments vary considerably, and the experimental setups lack additional clinical parameters and thus clinical relevance.  相似文献   

18.
Neonatologists often experience sodium ion level difference between an arterial blood gas analyzer (direct method) and an autoanalyzer (indirect method) in critically ill neonates. We hypothesize that clinical factors besides albumin and protein in the blood that cause laboratory errors might be associated with sodium ion level difference between the 2 methods in very-low-birth-weight infants during early life after birth. Among very-low-birth-weight infants who were admitted to Jeonbuk National Hospital Neonatal Intensive Care Units from October 2013 to December 2016, 106 neonates were included in this study. Arterial blood sample was collected within an hour after birth. Blood gas analyzer and biochemistry autoanalyzer were performed simultaneously. Seventy-six (71.7%) were found to have sodium ion difference exceeding 4 mmol/L between 2 methods. The mean difference of sodium ion level was 5.9 ± 6.1 mmol/L, exceeding 4 mmol/L. Based on sodium ion level difference, patients were divided into >4 and ≤4 mmol/L groups. The sodium level difference >4 mmol/L group showed significantly (P < .05) higher sodium level by biochemistry autoanalyzer, lower albumin, lower protein, and higher maximum percent of physiological weight than the sodium level difference ≤4 mmol/L group. After adjusting for factors showing significant difference between the 2 groups, protein at birth (odds ratio: 0.835, 95% confidence interval: 0.760–0.918, P < .001) and percent of maximum weight loss (odds ratio: 1.137, 95% confidence interval: 1.021–1.265, P = .019) were factor showing significant associations with sodium level difference >4 mmol/L between 2 methods. Thus, difference in sodium level between blood gas analyzer and biochemistry autoanalyzer in early stages of life could reflect maximum physiology weight loss. Based on this study, if the study to predict the body''s composition of extracellular and intracellular fluid is proceeded, it will help neonatologist make clinical decisions at early life of preterm infants.  相似文献   

19.
Our study sought to determine whether the size of the residual apical pleural space in young patients with primary spontaneous pneumothorax (PSP) following video-assisted thoracoscopic surgery is associated with the risk of recurrence.We retrospectively reviewed patients (≤30 years’ old) with primary spontaneous pneumothorax following thoracoscopic surgery (2002–2010) in a university-affiliated hospital. The size of residual apical pleural space was estimated by measuring the apex-to-cupola distance on a postoperative chest radiograph at 2 time windows: first between postoperative day (POD) 0 and 3, and second between POD 4 and 14.A total of 149 patients were enrolled with a median follow-up of 11.2 months (interquartile range, 0.95–29.5 months), of whom 141 (94.6%) were male with a mean age of 20 years. The postoperative recurrence rate was 11.4%. Comparing the characteristics between the patients with and without recurrent pneumothorax, the patients with recurrence were younger (18.2 + 2.4 vs 20.7 + 3.7 years, P = 0.008), with a lower rate of pleurodesis (35% vs1 69%, P = 0.037), longer apex-to-cupola distance at POD 0 to 3 (22.41 ± 19.56 vs 10.07 ± 10.83 mm, P < 0.001) and POD 4 to 14 (11.82 ± 9.75 vs 5.54 ± 8.38 mm, P = 0.005) than the patients without recurrence. In a multivariate logistic regression model for recurrent pneumothorax, age <18 years (P = 0.026, odds ratio [OR]: 4.694), apex-to-cupola distance at POD 0 to 3 >10 mm (P = 0.027, OR: 5.319), and no pleurodesis during VATS (P = 0.022, OR: 5.042) were independent risk factors for recurrent pneumothorax.The recurrence rate was not low (11.4%) in young patients with PSP following VATS. Residual apical pleural space with apex-to-cupola distance of 10 mm or greater at POD 0 to 3, younger age, and no pleurodesis would increase postoperative recurrence of primary spontaneous pneumothorax.  相似文献   

20.
Sodium intake was reported to be related to metabolic syndrome (MS). Although a strong association between sodium intake and blood pressure (BP) has been reported, the relationship between sodium intake and other components of MS is unknown.An observational study of 18,146 adults in the Korea National Health and Nutrition Examination Survey IV-V databases (2008–2011) was performed. Estimates of 24-h sodium excretion were made from a single fasting urine sample.A significant positive association was found between sodium excretion and systolic BP and between sodium excretion and diastolic BP in participants with and without hypertension after adjusting for multiple covariates (P < 0.001 for trend). The relationship between triglyceride or glucose levels and sodium excretion was linear (P < 0.005). In both men and women, a positive relationship between sodium excretion and waist circumference and an inverse relationship between sodium excretion and high-density lipoprotein were found (P ≤ 0.001). Body fat percentage, body fat mass, and insulin level were positively related to sodium excretion (P ≤ 0.001), and HOMA-IR was significantly associated with sodium excretion (P < 0.05). The risk of MS was elevated 1.279-fold in the second quartile of sodium excretion (95% CI, 1.088–1.504, P = 0.003), 1.479-fold in the third quartile (95% CI, 1.262–1.734; P < 0.001), and 1.929-fold in the highest quartile (95% CI 1.654–2.249, P < 0.001) compared with the lowest quartile.Sodium intake is significantly associated with all components of MS, body fat, and insulin resistance. Therefore, a high-salt diet is a significant risk factor for MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号