首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this study was to screen for antigens of the hepatitis?C virus (HCV) to establish a new double antibody sandwich-lateral flow immunoassay (DAS-LFIA) method for testing the presence of anti-HCV antibodies in human serum or plasma. A series of different recombinant HCV proteins in Escherichia coli cells were constructed, expressed, purified and the new DAS-LFIA strip was developed. The sensitivity and specificity of new the DAS-LFIA strip were evaluated by detecting 23?HCV-positive sera, a set of quality control references for anti-HCV detection that contain known amounts of anti-HCV antibodies, and 8?HCV-negative sera. A total of 300?clinical serum samples was examined by both the new DAS-LFIA strip and enzyme-linked immunosorbent assay (ELISA). Data were analyzed using SPSS?11.5 software. The sensitivity and specificity of the new DAS-LFIA strip were 100%. The lowest test line of the HCV DAS-LFIA strips was 2?NCU/ml. Additionally, the concordance between the new DAS-LFIA strip and ELISA methods was 94.33%. In conclusion, our new testing method is rapid, simple, sensitive and specifically detects the presence of anti-HCV antibodies in human serum or plasma. Therefore, it may be used for monitoring HCV.  相似文献   

2.
丙型肝炎病毒抗原检测方法的建立   总被引:15,自引:0,他引:15  
目的以特异性单克隆抗体为基础建立丙型肝炎病毒(HCV)抗原检测的酶联免疫吸附(ELISA)法,探索从血浆或血清中检测HCV抗原的可能性.方法利用我们制备的抗-HCV核心及NS3区单克隆抗体(McAbs),进行多种交叉组合模式的分析,确立实验室模式,并测定348份义务献血员血样,确定此方法的Cutofff值,并分析146份抗-HCV阳性及225份抗-HCV阴性血浆,阳性结果用套式PCR试剂盒确证.结果构建了以抗-HCV核心区单抗C39及NS3区单抗C7-6为包被抗体,以C39及NS3区C7-57为标记抗体的夹心ELISA检测模型,以C7为抗原,其检出灵敏度为5ng/ml,其Cutoff值为阴性对照均值±0.25.146份抗-HCV阳性样本中,11份为抗原反应阳性,225份抗-HCV阴性样本中,16份为抗原阳性,这些阳性样本经PCR检测后,23份为HCVRNA阳性.结论用单抗构建的HCV抗原检测方法分别从抗-HCV阳性及阴性样本中检测出HCV抗原反应阳性样本,并经PCR确证,表明直接从血浆样本中检测HCV抗原是可能的,这将对于HCV和基础研究及控制HCV的传播有重要意义.  相似文献   

3.
In acute and chronic hepatitis B, antibodies of the immunoglobulin M (IgM) class against the hepatitis B core antigen (anti-HBc IgM) have been demonstrated. For the determination of anti-HBc IgM, a sensitive enzyme immunoassay with anti-mu-coated flat-bottomed microtiter plates is described and evaluated. The specificity of the anti-HBc IgM test system was proven by pretreatment of presumed anti-HBc IgM-positive samples with anti-mu to block anti-HBc IgM. The test system was highly sensitive. In the acute stage of hepatitis B, anti-HBc IgM could be demonstrated in serum dilutions up to 10(-7) (mean titer, 10(-5)), and in sera from patients with chronic hepatitis B, the mean titer was 10(-3). In a study of unselected patients whose sera were sent at irregular intervals for testing, anti-HBc IgM persisted in a high percentage (52%) for at least 13 to 18 months after onset of illness despite the fact that these patients eliminated hepatitis B surface antigen (HBsAg) and produced antibodies to HBsAg (anti-HBs). By using the anti-HBc IgM test as an additional aid in the diagnosis of acute HBsAg-negative hepatitis, the hepatitis B etiology could be established in 13 of 42 patients (31.4%). Investigations of the prevalence of anti-HBc IgM in different groups of patients with chronic hepatitis B infection showed 89.4% anti-HBc IgM-positive results in patients with chronic active hepatitis B, 60% in patients with HBsAg-negative chronic active hepatitis, 58.2% in patients with primary liver carcinoma and markers of hepatitis B infections, and 34.9% in healthy carriers of HBsAg.  相似文献   

4.
5.
Hepatitis C virus (HCV) exposure in blood donors is determined serologically by the detection of anti-HCV antibodies in serum or plasma. However, a "window" period of 30-70 days after exposure exists where specific antibodies to HCV antigens are not detected. The use of nucleic acid testing for the detection of HCV RNA or antigen testing for the detection of HCV core protein have resulted in dramatic reductions in the pre-seroconversion window period. In this study, an automated HCV core antigen detection test was developed. This magnetic microparticle-based assay utilizes anti-HCV core monoclonal antibody to capture antigen present in human serum or plasma. Captured antigen is then detected using an anti-HCV core monoclonal antibody conjugated with a chemiluminescent compound. The specificity of this assay was established at 99% upon testing a population of normal volunteer blood donors. Sensitivity was determined by testing 16 commercially available HCV seroconversion panels representing genotypes 1a, 1b, 2b, and 3a. In each panel tested, HCV core antigen was detected prior to anti-HCV antibody, resulting in a reduction of the window period by greater than 23 days on average, and greater than 34 days on panels initially NAT negative. In addition, HCV core antigen was detected in >97% of HCV RNA positive/antibody negative specimens, exhibiting sensitivity nearly equivalent to nucleic acid testing in the pre-seroconversion window period for the panels examined.  相似文献   

6.
用原位酶联免疫吸附法检测甲型肝炎病毒   总被引:2,自引:0,他引:2  
目的 采用一种更加简单和敏感的检测方法对甲型肝炎病毒(HAV)进行检测。方法 用甲型肝炎病毒疫苗株H2M20K株和野毒株合34感染KMB17二倍体细胞,于96孔微量细胞板上培养,并在原位用HAV特异的单克隆抗体与单层细胞上的病毒结合,辣根过氧化物酶标记的抗鼠IgG作为指示,以细胞对照A值(OD)均数的18倍判为阳性。结果 病毒增殖动态显示,高峰期为20~25d,比ELISA终点滴定法提前4~6d;两种方法同时做13个样品的感染性滴度比较,结果差异无显著意义(t=1.13,P>0.05)。原位EIA较好地指示中和试验的结果;直接从12份粪便中分离病毒,经第一代培养检测有5份阳性。结论 EIA敏感性与ELISA法相似,由于原位EIA直接检测病毒细胞系统,有操作简单,重复性好等优点,可取代ELISA终点滴定法,同时也可望用于对其他病毒细胞系统的检测。  相似文献   

7.
8.
Recently, noninvasive diagnostic tests for Helicobacter pylori infection have gained in significance. We have developed a sensitive and specific noninvasive immunoassay based on the detection of an H. pylori circulating antigen (HpCA) in sera from H. pylori-infected individuals. Monospecific antibody and Western blot analyses were used to demonstrate the presence of the target antigen in H. pylori cell lysate and serum samples. A novel enzyme-linked immunosorbent assay (ELISA) was developed for the detection of HpCA in serum. Endoscopic biopsy specimens from the gastric antra of 221 individuals (143 males and 78 females) with dyspeptic symptoms were evaluated for H. pylori infection, with culture used as a "gold standard" for diagnosis. The target H. pylori antigen was identified at 58 kDa. HpCA has been detected by ELISA with high degrees of sensitivity, specificity, and efficiency (>90%), and ELISA results show no significant difference (P > 0.05) from results of H. pylori culture of gastric biopsy specimens. The test's positive and negative predictive values were also high (95 and 86%, respectively). In conclusion, a sensitive and specific immunoassay was developed for the detection of HpCA in human serum. This test can be applied for noninvasive laboratory and field diagnoses of H. pylori infection.  相似文献   

9.
10.
11.
PurposeThe major bottleneck in most developing countries to attain the WHO goal of eliminating hepatitis C as a public health threat by 2030 is the limited access to molecular testing and loss of infected patients to follow up. Many of the hepatitis C virus (HCV) infected patients fail to get the confirmatory HCV RNA test done after initial screening for anti-HCV antibody. The hepatitis C core antigen (HCVcAg) chemiluminescence-based assay which is newly introduced in the Indian health setup could prove to be a potential marker in the single-point screening and confirmation of HCV infection. This study was done to evaluate the performance of the HCVcAg assay for diagnosis and treatment monitoring of patients with HCV infection.MethodsIn this retrospective study 208 archived plasma samples from 184 patients were retrieved and all three markers for the laboratory diagnosis of HCV infection, anti-HCV, HCV RNA and HCVcAg were performed in a single freeze thaw cycle. For a subset of patients (n ​= ​24), paired samples, baseline samples and samples collected at 12 weeks after completion of treatment (SVR12) were available.ResultsThe sensitivity and specificity of the HCVcAg assay were 91.58% and 99.12% respectively with HCV RNA as the gold standard for the detection of active infection. There was a strong correlation between HCVcAg and HCV RNA (R ​= ​0.85, p ​< ​0•0001). Among the paired samples, the concordance between the HCVcAg and HCV RNA at baseline and at SVR12 was 95.8%.ConclusionThe HCVcAg assay showed a good correlation with the gold standard HCV RNA assay, especially in the case of treatment naïve patients. Thus, the use of HCVcAg assay as tool for testing and confirmation of HCV infection has the potential to increase the uptake of HCV testing.  相似文献   

12.
游离丙型肝炎病毒核心抗原检测的临床价值探讨   总被引:4,自引:0,他引:4  
目的:探讨游离丙型肝炎病毒(HCV)核心抗原检测在HCV感染诊断中的价值。方法:采用荧光定量PCR法检测HCV-RNA、ELISA法同步检测抗-HCV和游离HCV核心抗原。结果:191例HCV感染者HCV-RNA的检出率为71·2%(136/191);抗-HCV的检出率为97·4%(186/191);游离HCV核心抗原的检出率为33·0%(63/191)。其中有2例经抗病毒治疗的患者HCV-RNA和抗-HCV检测均阴性,但游离HCV核心抗原检测阳性;另有1例患者抗-HCV阴性,而游离HCV核心抗原阳性,经HCV-RNA证实为HCV感染。27例非HCV感染者HCV-RNA、抗-HCV和游离HCV核心抗原检测结果均为阴性。结论:HCV核心抗原检测作为抗-HCV检验的补充试验对HCV感染的诊断具有重要价值。  相似文献   

13.
The British Columbia Center for Disease Control laboratory performs approximately 95% of all hepatitis C virus (HCV) antibody tests for the province's 4 million inhabitants. In 2002, the laboratory tested 96,000 specimens for anti-HCV antibodies, of which 4,800 (5%) were seroreactive and required confirmation of active infection. Although HCV RNA assays with a sensitivity of 50 IU/ml or less are recommended for the confirmation of active HCV infection, given the large number of seroreactive specimens tested annually, we evaluated the Ortho trak-C assay (OTCA) as a second-line confirmatory test and determined its limit of detection (LoD). Of 502 specimens from treatment-na?ve anti-HCV-positive individuals, 478 had sufficient volumes for evaluation by the OTCA and HCV RNA tests. Core antigen was not detected in 147 of 478 (30.8%) of these specimens, of which 37 of 147 (25.2%) were shown to be viremic by the VERSANT HCV (version 3.0) (branched-DNA) assay and/or the VERSANT HCV qualitative assay. Testing of 144 replicates of a World Health Organization standard dilution series indicated that the LoD of OTCA was approximately 27,000 IU/ml. This LoD is consistent with the inability of OTCA to detect core antigen in clinical specimens with low viral loads. We conclude that OTCA has limited value as a confirmatory test for the diagnosis of active HCV infection because 37 of 367 (10%) of viremic specimens had undetectable core antigen. Qualitative HCV RNA testing remains the present standard for the confirmation of active HCV infection in the diagnostic setting.  相似文献   

14.
The objective of the study was to assess three immunoblot assays, the Deciscan HCV Plus, the Riba and the Inno-Lia, on 44 discordant samples with three EIA kits. These immunoblots were considered as confirmation reagents. A result was considered as a false positive by anti-HCV antibody assay if the three immunoblots were negative or if two immunoblots were negative with the third being indeterminate and a negative virological genomic diagnosis observed on all the samples. The result was positive if at least two immunoblots out of three were positive. Thus, 34 samples were considered as false positive and ten samples were excluded because it was impossible to conclude between true or false positive result. The 44 discordant results were never confirmed as positive by the use immunoblot or PCR. The three immunoblots were negative for half of the samples and two immunoblots and one indeterminate were observed for 77% of the samples. The false positive results by the Monolisa assay were more often found indeterminate with the Deciscan assay than with the other immunoblots. That was also checked for Vitros/Riba pair. One of the explanations could be the use of common antigens for the reagents from the same manufacturer. The Inno-Lia test is the most specific immunoblot according to the results obtained in our study.  相似文献   

15.
Corzyme-MTM (Abbott Laboratories, North Chicago, IL), a newly introduced kit for the measurement of serum IgM antihepatitis B core antigen by enzyme immunoassay, was evaluated for the diagnosis of acute B-viral hepatitis (AVH-B). The study included 175 acute viral hepatitis patients with transient hepatitis B surface antigen (HBsAg). Sera from 160 were tested on multiple occasions until their HBsAg cleared. IgM anti-HBc was found in 171 of 175 patients (98.4%) during the acute phase. The serum samples from 42 patients with liver biopsy-proven chronic active hepatitis, type B (CAH-B), and 18 patients with persistent hepatitis, type B (PH-B), were analyzed for the presence of IgM anti-HBc, using the same technic. None of the sera from 42 patients with CAH-B and only 2 of the 18 patients with PHB had IgM anti-HBc. Thus, the measuring IgM anti-HBc using Corzyme-M kit is helpful in the diagnosis of AVH-B and in the discrimination of acute from chronic HBV infections.  相似文献   

16.
An early diagnosis of Japanese encephalitis (JE) is important for timely clinical management and epidemiological control in areas where multiple flaviviruses are endemic. The NS1 antigen has an advantage over IgM enzyme-linked immunosorbent assay (ELISA) for early confirmatory diagnosis of Japanese encephalitis virus (JEV) infection due to its proliferation on the surface of the host cells in the acute phase of infection. In this study, the development and evaluation of JE-specific NS1 antigen capture ELISA is described using high-affinity monoclonal antibody specific to the recombinant NS1 protein for early diagnosis of JE. The gene encoding NS1 protein was cloned and expressed in the pQE30UA expression vector followed by purification of the recombinant protein by affinity chromatography. A sandwich ELISA for antigen detection was developed using purified rabbit IgG antibody and mouse monoclonal antibody as the capture and detector antibody, respectively. The application of JE NS1 antigen ELISA for early diagnosis was evaluated with 120 acute phase sera and 80 CSF samples. The comparative evaluation of the JE NS1 antigen ELISA by real-time RT-PCR revealed 97% concordance with a sensitivity and specificity of 97% and 98%, respectively. The JE NS1 antigen was detectable in the blood from the first day up to day 9 after the onset of symptoms. These findings suggest that the JEV NS1 antigen capture ELISA may help early diagnosis of JE infection.  相似文献   

17.
The genome of hepatitis C virus (HCV) consists of seven functional regions: the core, E1, E2/NS1, NS2, NS3, NS4, and NS5 regions. The U. S. Food and Drug Administration-licensed 2.0G immunoassay for the detection of anti-HCV uses proteins from the core, NS3, and NS4 regions (McHutchinson et al., Hepatology 15:19-25, 1992). The 3.0G enzyme-linked immunosorbent assay includes the protein from the NS5 region (Uyttendaele et al., Vox Sang. 66:122-129, 1994). The necessity of detecting antibodies to viral envelope proteins (E1 and E2) and to different genotype samples has been demonstrated previously (Chien et al., Lancet 342:933, 1993; Lok et al., Hepatology 18:497-502, 1993). In this study we have attempted to improve the sensitivity of the anti-HCV assay by developing a single multiple-epitope fusion antigen (MEFA; MEFA-6) which incorporates all of the major immunodominant epitopes from the seven functional regions of the HCV genome. A nucleic acid sequence consisting of proteins from the viral core, E1, E2, NS3, NS4, and NS5 regions and different subtype-specific regions of the NS4 region was constructed, cloned, and expressed in yeast. The epitopes present on this antigen can be detected by epitope-specific monoclonal and polyclonal antibodies. In a competition assay, the MEFA-6 protein competed with 83 to 96% of genotype-specific antibodies from HCV genotype-specific peptides. This recombinant antigen was subsequently used to design an anti-HCV chemiluminescent immunoassay. We designed our assay using a monoclonal anti-human immunoglobulin G antibody bound to the solid phase. Because MEFA-6 is fused with human superoxide dismutase (h-SOD), we used an anti-human superoxide dismutase, dimethyl acridinium ester-labeled monoclonal antibody for detection. Our results indicate that MEFA-6 exposes all of the major immunogenic epitopes. Its excellent sensitivity and specificity for the detection of clinical seroconversion are demonstrated by this assay.  相似文献   

18.
The rate of HBsAg in 6,976 B-human chorionic gonadotropin (B-hCG)-positive specimens, as determined by the Auszyme Monoclonal assay (Abbott Laboratories, Abbott Park, Ill.), was 0.56% (39 of 6,986 repeatedly reactive [RR] and confirmed-positive specimens). All RR and confirmed specimens were hepatitis B virus positive by at least one additional test, yielding an assay specificity of 99.96%. The findings argue against unique attributes in the pregnant population that might produce inaccurate assay results.  相似文献   

19.
Wei SH  Yin W  An QX  Lei YF  Hu XB  Yang J  Lu X  Zhang H  Xu ZK 《Archives of virology》2008,153(6):1021-1029
Hepatitis C virus (HCV) is a major cause of liver disease worldwide. HCV infection is associated with high morbidity and has become a major problem in public health. Until now, there has been no effective prophylactic or therapeutic vaccine. BCG, a live vaccine typically used for tuberculosis prevention, has been increasingly utilized as a vector for the expression of recombinant proteins that will induce specific humoral and cellular immune responses. In this study, recombinant BCG (rBCG) was engineered to express a HCV multi-epitope antigen CtEm, and HLA-A2.1 transgenic mice were immunized with rBCG-CtEm. High levels of specific anti-HCV antibodies targeted to mimotopes of HVR1 were detected in the serum. HCV-specific lymphocyte proliferation assay, cytokine determination and cytotoxicity assay indicated that HCV epitope-specific cellular immune responses were elicited in vitro. The rBCG-CtEm immunization conferred protection against infection with the recombinant vaccinia virus (rVV-HCV-CNS) in vivo. These results suggest that rBCG expressing multi-epitope antigen may serve as an effective vaccine against HCV infection.  相似文献   

20.
A comparative evaluation of the following commercial immunoassays for the detection of hepatitis B virus surface antigen (HBsAg) was performed: the Abbott AxSYM, Abbott IMx, and DPC IMMULITE assays. The specificity was 100% for all assays. Twelve samples were identified and were confirmed to be positive for HBsAg by all three methods. One additional sample was identified as reactive and was confirmed to be positive by the Abbott AxSYM assay only. Prior to confirmation testing the DPC IMMULITE assay produced significantly fewer false-positive results than the Abbott AxSYM assay (P < 0.05).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号