首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
目的 探讨消除腰椎MRI检查时椎间盘多平面多角度T2WI序列出现带状低信号伪影的可行方法.方法 应用SIEMENS AVANTO I.5T磁共振扫描仪,对42例临床怀疑腰椎间盘突出患者行腰椎常规矢状位和横断位多角度多平面扫描,采用快速自旋回波(TSE)序列、快速恢复快速自旋回波(TSE-Restore)序列,并由3名高年资医师对图像质量进行评价.结果 2种方法都能完全消除伪影,且图像质量完全符合诊断要求.结论 快速恢复快速自旋回波联合分段扫描技术是最优化消除饱和伪影的方法.  相似文献   

2.
目的:探讨Propeller技术对减少头部运动伪影及磁敏感伪影的应用价值。方法:对53例磁共振头颅检查时躁动或难以自控的患者行常规FRFSE T2WI和Propeller T2WI轴位扫描;对31例常规扩散加权图像(DWI)磁敏感伪影明显者进行Propeller DWI扫描。观察并对照分析FRFSE T2WI和Propeller T2WI以及DWI与Propeller DWI的图像质量状况。结果:53例在T2WI存在明显运动伪影的患者,在行Propeller T2WI扫描后明显减少或消除了运动伪影,图像质量级别显著升高[(2.88±0.32,(1.11±0.30),P=0.00)]。31例在DWI有显著磁敏感伪影的患者,采用Pro-peller DWI后,明显消除磁敏感伪影,图像质量明显提高[(2.84±0.35,(1.06±0.17),P=0.00)]。结论:应用Propeller技术能够明显减少或消除T2WI及DWI上运动伪影及磁敏感伪影,显著改善图像质量。  相似文献   

3.
梁汉欢  梁菊香  陈华栋 《中国现代医生》2009,47(23):105-106,F0003
目的 探讨刀锋伪影校正(BLADE)T2WI及单次激发快速自旋回波(SS-TSE TEWI)序列在1.5T磁共振成像的常规序列出现运动伪影受检者的临床应用价值.方法 26例出现了运动伪影的受检者,进行BLADE T2WI和SSTSE T2WI扫描,采用卡方检验及配对样本符号秩和检验评价两种序列减轻运动伪影的能力,同时对两种序列图像清晰度及对比度进行对比.采用配对样本符号秩和检验.结果 使用BLADET2WI(Z=-5.099,P<0.000)和SS-TSET2WI(Z=-5.099,P<0.000)扫描方法所获得的图像运动伪影均较常规序列减少,分别还有4/26例及3/26例存在轻度的运动伪影,两种序列减轻运动伪影能力未见统计学差异(χ2=0.165,P=0.685).但PROPELLER FSE,T2WI图像的清晰度、对比度优于SS-FSE T2WI(Z=-4.583,P<0.000).结论 PROPELLER和SS-TSE扫描技术均具有减轻呼吸运动伪影的能力,但PROPELLER T2WI对脑实质的显示更为理想,对不能配合的受检者具有较高临床实用价值.  相似文献   

4.
宋宏伟 《黑龙江医学》2014,38(9):1030-1031
目的探究在治疗臂丛神经损伤中磁共振成像技术的诊断价值。方法运用磁共振技术对25例健康的自愿者和14例臂丛神经损伤的患者进行双侧臂丛常规的快速自旋回波序列T1加权横轴位(T1W/TSE)、快速自旋回波序列T2加权斜冠状位和横轴位(T2W/TSE)、重T2WI反转恢复脂肪抑制技术成像序列冠状位扫描(STIR/long TE)、弥散加权背景抑制成像序列轴位扫描(DWIBS)成像。结果 T1WI轴位、T2WI轴位与斜冠位用于显示臂丛神经的椎间孔段和椎管内段成像具有较大优势;STIR/long TE和DWIBS用于显示臂丛神经干成像较好;T1WI可用于特异性显示血肿信号、局部或者脊髓内软组织的内出血;冠状位STIR/long TE、DWIBS可用于显示节后神经损伤或病变,可显示出神经干的信号异常或增粗,准确定位神经损伤。结论磁共振常规的扫描序列加以结合磁共振神经成像技术在对臂丛神经损伤的定性定位诊断方面应用前景广阔。  相似文献   

5.
目的:探讨基于深度学习重建(deep learning reconstruction,DLR)技术的快速自旋回波(turbo spin echo,TSE)T2加权成像(T2 weighted imaging,T2WI)序列提高纵隔T2WI图像质量和减少扫描时间的应用价值。方法:前瞻性收集35例纵隔病变的患者进行纵隔常规T2WI序列和基于DLR的T2WI(T2WIDLR)序列扫描。由2位放射科医师各自独立对两组图像的伪影、图像清晰度、病灶的细节显示和整体图像质量进行定性评分,并测量和比较两组图像的病灶信噪比(SNR 病灶)和病灶与竖直肌的对比噪声比(CNR 病灶/肌肉)。结果:T2WIDLR在伪影、图像清晰度、病灶细节显示和整体图像质量的评分均优于常规T2WI(P均 < 0.001)。 T2WIDLR序列图像的SNR和CNR均优于常规T2WI序列(P均 < 0.001)。结论:与常规T2WI序列相比,T2WIDLR序列的运动伪影更少,图像清晰度、病灶细节显示和整体图像质量更优,图像SNR和CNR更高,在纵隔疾病的临床应用中有较大潜力。  相似文献   

6.
目的 探讨并行采集技术(iPAT)在上腹部MRI检查中的应用价值.方法 对56例患者,首先进行快速自旋回波(TSE)序列的T2WI+FS和扰相位梯度回波(FLASH)序列的T1WI常规扫描,然后在参数保持一致的情况下采用iPAT扫描,测量并计算图像的信噪比(SNR)及对比噪声比(CNR).呼吸运动伪影对图像质量的影响通过评分来判定.结果 无论是T2WI+FS序列还是T1WI序列,iPAT使用前后SNR及CNR的差异均无统计学意义(均P >0.05).使用iPAT后呼吸运动伪影的影响明显减小,得分为4分和3分的图像明显多于使用iPAT前,差异有统计学意义(P<0.05).结论 对于屏气配合不佳的中老年患者,采用iPAT进行上腹部MRI检查,采集时间缩短,呼吸运动伪影减少,较常规的MRI检查更有优势.  相似文献   

7.
目的:探讨MR各序列成像在脑出血性病变的敏感性。方法:回顾性分析100例脑出血患者常规自旋回波(SE)T1WI、快速自旋回波(TSE)T1WI、液体衰减反转恢复序列(FLAIR)、扩散加权成像(DWI)和小角度激发快速梯度回波序列(T2—FFE)资料,比较SE—EPI、T2-FFE序列脑出血病灶的显示率,分析其信号特征,并探讨SE—EPI代替T2-FFE的可行性。结果:T2-FFE为显示脑出血性病灶最敏感的序列,能显示常规序列所不能显示的微出血。无论在检出脑出血灶,还是图像对比度,SE—EPI均远低于T2-FFE。结论:T2-FFE序列能提高脑出血病灶的检出数及早期诊断率,应作为常规扫描序列:在临床脑出血筛选方面,SE—EPI无法代替T2-FFE。  相似文献   

8.
目的:评价常用T2WI快速扫描序列:快速自旋回波(TSE)序列、半傅立叶采集单次激发快速自旋回波(HASTE)序列的反转恢复HASTE(IR-HASTE)序列、真实稳态进动快速成像(true-FISP)序列、自旋回波平面成像(SE-EPI)序列在肝癌诊断中的作用。方法:肝癌患者34例,分别进行四项T2WI快速扫描序列扫描,并进行信噪比SNR、对比噪声比CNR、图像质量、病灶检出率的比较。结果:各扫描序列的SNR、CNR、图像质量有统计学意义,病灶检出率无差异性。结论:快速自旋回波(TSE)序列综合评价最好,是肝癌诊断中首选的扫描序列,其它序列可提供补充信息。  相似文献   

9.
新生儿颅内出血(NICH)已成为一种常见病,由于病因的多样性,出血可发生在颅内任何部位,往往伴有不同程度的脑损伤后遗症。无电离辐射、多方位多功能成像的核磁共振成像(MRI)检查成为NICH早期诊断及后期随访的必备手段。快速自旋回波(TSE)T1加权(T1WI)黑血技术是以常规T1WI序列基础,辅以经典的黑血技术——双反转恢复回波(DIR),因此,双反转快速自旋回波T1加权序列能够有效抑制血管源性伪影,降低常规T1WI序列对NICH诊断的假阳性。本文就TSE T1WI黑血技术原理及其在NICH中的应用前景予以综述。  相似文献   

10.
目的评价平衡快速梯度回波序列(balallce-FFE,B—FFE)在诊断主动脉夹层的临床应用价值。方法26例怀疑主动脉夹层的患者分别行快速自旋回波(TSE)和B-FFE检查,然后对TSET2WI序列与B-FFE序列的图像清晰度、血管显示主动脉夹层的范围、内膜片的形态、破口的位置、真假腔和附壁血栓以及与周围大血管的关系等检出情况进行分析比较。结果B—FFE序列的图像清晰度、血管显示及解剖显示均优于TSET2WI序列,并且在扫描时间上有很大优势。结论B—FFE序列能很好地显示主动脉夹层的范围、内膜片的形态、破口的位置、真假腔和附壁血栓以及与周围失血管的关系:扫描速度快,几乎无运动伪影,对较重或不能屏气的患者有明显优势,可作为主动脉夹层的重要检查手段。  相似文献   

11.
目的 研究弥散加权成像(DWI)诊断CO中毒迟发性脑病的应用价值。方法 对31例CO中毒迟发性脑病患者均行MR DWI检查,MRI检查在CO中毒后15~90d内完成,DWI使用单次激发平面回波序列,TR=2900ms,TE=84ms,b值为0和1000s/mm2。通过常规MRI、DWI及ADC图评价脑室周围脑白质区信号改变,测量病变区ADC值并与正常信号区进行对比。结果 所有患者DWI序列均显示在双侧脑室周围脑白质区及半卵圆中心弥漫高信号影,显示范围与T2WI及Flair序列所显示范围相似,ADC图显示为轻度低信号或等信号,其平均ADC值均较T2WI及Flair序列显示正常的区域明显减低(P<0.05)。结论 脑白质区ADC值减低的程度和持续时间与患者临床进展过程有关,通过对ADC值的观察能对CO中毒迟发性脑病患者的临床进展过程及预后进行推测。  相似文献   

12.
Background This study was to investigate the safety of two types of commercially available lumbar artificial discs (CHARITE and PRODISC-L) during a magnetic resonance imaging (MRI) procedure in a 1.5-Tesla MR system, and to evaluate the size of metal artifacts on the MR image for different sequences. Methods A 1.5-Tesla clinical MR imaging system was used. The degree of deflection of the endplates of two artificial discs was evaluated by an angle-measurement instrument at the portals of the MRI scanner. The heating effect of the radio frequency (RF) magnetic field was evaluated by using "worst-case" imaging sequences on a human cadaver implanted with an artificial lumbar disc at the L5/S1 intervertebral disc location. The temperatures of the tissue adjacent to the implant, and of the L4/L5 intervertebral disc (used as a control) were measured, respectively, using a digital probe thermometer before and after the MRI scan sequence. A rectangular water phantom was designed to evaluate the metal artifacts of these two artificial discs under different MR imaging sequences. Results The maximal deflection angle of the endplate of the implants under a static MR field was 7.5 and 6.0 degrees, for the CHARITE and PRODISC-L, respectively. The difference between temperature rise of tissue adjacent to the two types of artificial discs and the temperature rise of the L4/L5 control location was 0.4 and 0.6℃, respectively. The size of metal artifacts on images of TSE (T1/T2 -weighted), STIR and Turbo Dark Fluid sequences were relatively less than those of TSE fat saturation, Flash and SE (Tl-weighted) sequences. Conclusions The CHARITE and the PRODISC-L artificial disc do not present an additional hazard or risk to a patient undergoing an MRI procedure using a scanner operating with a static magnetic field of 1.5T or lower. Image artifacts from the implants may present problems if the anatomical region of interest is in or near the area where these implants are located (e.g., vertebral canal at affected segment).  相似文献   

13.
BackgroundTime-of-flight (TOF) magnetic resonance (MR) angiography is based on flow-related enhancement using the T1-weighted spoiled gradient echo, or the fast low-angle shot gradient echo sequence. However, materials with short T1 relaxation times may show hyperintensity signals and contaminate the TOF images. The objective of our study was to determine whether subtraction three-dimensional (3D) TOF MR angiography improves image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times.MethodsDuring the 12-month study period, patients who had masses with short T1 relaxation times noted on precontrast T1-weighted brain MR images and 24 healthy volunteers were scanned using conventional and subtraction 3D TOF MR angiography. The qualitative evaluation of each MR angiogram was based on signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and scores in three categories, namely, (1) presence of misregistration artifacts, (2) ability to display arterial anatomy selectively (without contamination by materials with short T1 relaxation times), and (3) arterial flow-related enhancement.ResultsWe included 12 patients with intracranial hematomas, brain tumors, or middle-ear cholesterol granulomas. Subtraction 3D TOF MR angiography yielded higher CNRs between the area of the basilar artery (BA) and normal-appearing parenchyma of the brain and lower SNRs in the area of the BA compared with the conventional technique (147.7 ± 77.6 vs. 130.6 ± 54.2, p < 0.003 and 162.5 ± 79.9 vs. 194.3 ± 62.3, p < 0.001, respectively) in all 36 cases. The 3D subtraction angiography did not deteriorate image quality with misregistration artifacts and showed a better selective display of arteries (p < 0.0001) and arterial flow-related enhancement (p < 0.044) than the conventional method.ConclusionSubtraction 3D TOF MR angiography is more appropriate than the conventional method in improving the image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times.  相似文献   

14.
为评价磁共振(MR)动脉期和门脉期动态成像对肝癌的检测价值,运用快速扰向梯度回波技术对3 4例患者进行了MR动态成像.在静脉团注GD-DTPA的时间内连续采集,分别在动脉期与门脉期成像并与平扫SE-T1像、SE-T2像对肝癌的检测数目进行比较.结果显示64个得到证实的肝细胞癌(HCC)中,平扫SE-T1像发现56个(占88%)、SE-T2像发现54个(84%)、动脉期成像发现58个(90%)、门静脉期成像发现46个(72%).11个HCC仅在平扫SE列显示,8个HCC仅在动脉期得到确认,1个HCC仅在门静脉期得到确认.动态成像对非HCC肿瘤的检出率未增加.示动脉期和门静脉期动态成像能检测出某些SE平扫无法检出的HCC肿瘤,是对常规MR检查方法有力补充.  相似文献   

15.
内耳内听道及面神经的磁共振成像研究   总被引:1,自引:0,他引:1  
目的 探讨内耳内听道及面神经的磁共振成像技术及临床应用。方法 45例耳部MR检查正常者采用三维稳态结构相干序列(3D-constructive inference in the steadystate,3D-CISS)和采用快速自旋回波序列(turbospinecho,TSE)作颞骨容积扫描,之后行最大信号强度投影(MIP)技术处理,进行图像对比。结果 3D-CISS对螺旋板、前庭阶、鼓阶、椭圆囊、球囊的显示对比TSE具有显著性意义。结论 3D-CISS对内耳内听道细微结构的显示优于TSE。  相似文献   

16.
MR弥散张量三维脑白质纤维束成像   总被引:6,自引:0,他引:6  
目的 磁共振弥散张量成像(MR-DTI)是一种新的无创性成像方法,它不同于常规T2加权成像(T2WI)和弥散加权成像(DWI),它可以准确地反映水分子扩散的方向信息,并通过特殊的软件处理,能够实现白质的纤维跟踪与可视化.本文应用磁共振扩散张量成像技术显示人脑白质纤维束,探讨其与正常解剖学描述的一致及其临床应用的可行性.方法 6例志愿者,男4例,女2例,年龄范围21~62岁.于GE 1.5T Sign CV/Ⅰ型磁共振扫描机,相控阵列鸟笼状头部线圈,采用单次激发回波平面弥散张量成像序列扫描,GE公司Workstation中的Functool软件进行DTI数据的后处理及三维脑白质纤维束示踪.结果 能较好显示的白质纤维有:连合系、钩束、上下纵束、下额枕束、内囊等.上述纤维束与已知的解剖学上的正常的同名纤维束的描述具有较好的一致性.结论 通过DTI方法,我们可以获得一套较为完整的主要正常脑白质纤维束的解剖图,该方法是一种可使脑白质束快速可视化的新方法.  相似文献   

17.
高磁场MRI伪影的产生及抑制方法探讨分析   总被引:2,自引:0,他引:2  
目的:探讨高磁场MRI伪影的产生及抑制方法。方法:A组无选择性收集我院MRI开展初期的检查患者1000例,B组:选择采用伪影预防抑制措施后的MRI检查患者1000例。分别分析A、B组患者图像的各种伪影。B组病人状况与A组基本相似。结果:通过采取一系列的预防抑制措施后,B组的各部位伪影明显下降.由原来的13.6%降到4.2%。结论:正确认识各种伪影及其产生的原因,才能充分地利用这项技术,有效地抑制或消除伪影,提高图像质量。  相似文献   

18.
目的:探讨中场单次激发厚层投射磁共振尿路水成像(MRU)的临床应用价值。方法:16例正常和22例尿路病变患者,应用中场(0.5T)行单次激发厚层投射MRU成像。所有患者均行常规MRI成像。18例患才加作轴位2DFSE T2WI后行MIP(最大强度投影)重建MRU图像。结果:正常组:MRU可显示肾盂、肾盏及输尿管的大部分和膀胱。病变组:MRU可以使尿路病变准确定位。本组病变的定位准确率达100%,定性达84.2%。结论:MRU对尿路病变的定位定性的诊断有重要价值,对部分患者MRU可作为一种静脉肾盂造影(IVP)和逆行肾盂造影的替代方法。  相似文献   

19.
脑血吸虫病的MRI诊断(附9例报告)   总被引:2,自引:0,他引:2  
目的:探讨脑血吸虫病MRI表现特点及诊断价值。方法:对9例经手术病理或临床证实的脑血吸虫病的MRI资料进行回顾性分析。结果:(1)9例中,2例单发;7例多发,分布于顶颞枕叶皮层和皮层下区,其中2例同时见于小脑和脑干;(2)平扫:T1WI虫卵肉芽肿病灶为稍长T1略低信号,呈斑点状或结节状,同周围低信号水肿分界欠清;T2WI为等T2信号,常被水肿高信号掩盖;(3)Gd DTPA增强扫描,病灶大多呈明显均一强化;(4)灶周水肿较重而占位效应相对较轻;(5)吡喹酮驱虫治疗,病灶缩小,水肿消退。结论:结合病史与脑脊液血吸虫免疫学试验,MRI是诊断本病的可靠方法。  相似文献   

20.
金属固定假牙对头部MR图像的影响研究   总被引:8,自引:0,他引:8  
目的 :探讨金属固定假牙对头部 MR图像的影响。方法 :将 5 0例有金属固定假牙的病人按假牙的多少分成单牙组及多牙组 ,其中单牙组按材料的不同分铜合金、铬镍不锈钢合金、镍铬合金 3种 ,多牙组分铜合金、镍铬合金两种。分别采用 SE/ T1 WI、FSE/ T2 WI、FAST/ T2 WI行横断面、矢状面扫描 ,比较各组中不同材料在不同序列下的伪影。结果 :金属固定假牙所形成的伪影中 ,铜合金最小 ,镍铬合金最大 ;SE序列最小 ,与 FSE序列基本相同 ,FAST序列最大 ;伪影随固定假牙的数目增多而增大。结论 :金属假牙可形成伪影而致邻近组织失真 ,伪影对颅脑、颈椎的观察无影响 ,而对眼球、上颌窦及口腔结构因扫描序列材料的不同有不同程度的影响。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号