1.
Prospective, randomized studies must be performed when new surgical techniques or implants are evaluated. In this study, a new implant system was compared with the Charnley prosthesis, which over the years has been the most used hip implant in Sweden. Between 1985 and 1989, 410 hips were randomized to treatment with a Charnley or a Spectron total hip arthroplasty: 206 Charnley and 204 Spectron prostheses were implanted. The patients were operated on by a standardized procedure using a contemporary cementing technique. The patients were followed prospectively by an independent observer after 1, 3, 5 to 6, and 10 years. Harris Hip Score and patient satisfaction were recorded in the outcome evaluation. A total of 144 patients with 164 hips were deceased, and 15 patients (8 Charnley and 7 Spectron) have required a revision. Nine hips were revised because of aseptic loosening (5 Charnley stems and 4 Spectron metal-backed cups). The Charnley stem as well as the metal-backed Spectron cup had a higher risk for revision because of aseptic loosening. The Charnley ogee cup and the Spectron stem have performed remarkably well with no revision of these components. Seven Charnley prostheses dislocated, but no dislocation was recorded in the Spectron group. Survivorship calculations with a mean follow-up of 10 years revealed an overall 11-year survivorship of 94.5% +/- 3.4% (Charnley, 93.2% +/- 5.8%; Spectron, 95.9% +/- 3.0%). The clinical outcome did not differ between the 2 systems. The overall results in this old population, using a contemporary surgical technique, illustrate that cemented hip arthroplasty is an excellent treatment alternative for elderly patients.  相似文献   

2.
A total of 410 hips were randomized to treatment with either a Charnley (206 hips) or a Spectron (204 hips) total hip arthroplasty. The patients were operated on by a standardized procedure using a contemporary cementing technique and were followed after 1, 3, 5 to 6, and 10 years. The postoperative radiographs showed a significantly increased rate of malalignment and consequently low grade of cement mantle quality of the Charnley stem compared to the Spectron. No differences concerning cement mantle quality or positioning were found between the Charnley ogee cup and the metal-backed Spectron. Evaluation of the follow-up radiographs revealed 10 loose Charnley stems and 1 loose Spectron stem and 4 loose Charnley ogee cups and 23 loose Spectron metal-backed cups. The differences of revision rate for the femoral and acetabular components of the 2 prostheses were significant (P = .03, Charnley femoral component more frequent; P = .03, Spectron acetabular component more frequent). The radiographic evaluation strengthened this disparity. Poor wear characteristics of the metal-backed Spectron cup are perhaps the main reason for the highly significant difference in mechanical failure rate between the 2 cups. We therefore propose that metal-backing of cemented cups should be avoided, at least when combined with larger femoral heads. The difficulty in positioning the Charnley stem with an adequate cement mantle, especially in the absence of trochanteric osteotomy, might explain the inferior Charnley stem longevity in this study.  相似文献   

3.
We evaluated 34 total hip arthroplasties (THA) for avascular necrosis of the femoral head in 26 patients who were younger than 40 years at the time of the index operation. The average age at the time of THA was 283 (17-38) years. The mean follow-up was 10.9 (5-19) years. We used 6 cemented and 28 cementless acetabular components and a cemented polished tapered stem in all hips. The mean Charnley modified Merle d' Aubigné Postel score was 8.9 points preoperatively and 16.6 points at final follow-up. Two cemented metal-backed cups were revised because of aseptic loosening at 10 years, one cemented polyethylene cup failed at 12 years and 2 more all polyethylene cups had pending failure. The metal-backed cemented cups and the all polyethylene cups had a longer follow-up than the uncemented cups. Therefore and because of the proven unfavourable long-term outcome of the cemented metal-backed Exeter cup we are not able to draw any firm conclusions regarding the preferred choice between cemented and uncemented cups in this particular group of patients. On the femoral site none of the stems had to be revised. Our results show that a cemented polished tapered femoral component has an excellent survival in primary total hip replacement in young patients with avascular necrosis of the femoral head.  相似文献   

4.
BACKGROUND: Many studies have found a higher risk of revision after hip arthroplasty in younger patients. We evaluated the population-based survival of total hip arthroplasty (THA) in patients under 55 years of age and the factors affecting survival. METHODS: The Finnish Arthroplasty Register was established in 1980, and 74,492 primary THAs were entered into the register between 1980 and 2001. 4,661 of these were evaluated, all of which had been performed for primary osteoarthrosis on patients under 55 years of age. RESULTS: Proximally circumferentially porous-coated uncemented stems implanted between 1991 and 2001 had a 10-year survival rate of 99 (95% CI 98.5-99.6)% with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher in cemented stems than in proximally porous-coated (RR 5.5, p < 0.001) or HA-coated (RR 6.6, p = 0.01) uncemented stems implanted during the same period. According to Cox regression analysis of cups implanted 1991-2001, the risk of revision for all-polyethylene cemented cups was 3.0 times as high as that for press-fit porous-coated uncemented cups with aseptic loosening as endpoint (p = 0.01). However, when the endpoint was defined as any revision (including exchange of liner), there was no longer any difference between these two concepts, the 10-year survival rates being 94 (92.1-95.5)% for press-fit porous-coated uncemented cups and 93 (88.5-97.6)% for all-polyethylene cemented cups (p = 0.9). INTERPRETATION: Modern uncemented stems seem to have better resistance to aseptic loosening than cemented stems in younger patients. Thus, for younger patients, uncemented proximally circumferentially porous- and HA-coated stems are the implants of choice. Press-fit porous- and HA-coated uncemented cups may have better endurance against aseptic loosening than cemented cups in younger patients. However, when all revisions (including exchange of liner) are taken into account, the survival of modern uncemented cups is no better than that of all-poly cemented cups.  相似文献   

5.
On the basis of data from the Norwegian Arthroplasty Register during the period 1987-1993, we have compared times to revision for 10 different cemented total hip prostheses. A total of 11,169 patients, with 12,179 primary total hip replacements (THRs), performed with high viscosity cement for primary arthrosis and followed for a maximum of 6.4 years, were included in this study.

The Kaplan-Meier estimate of the overall percentage revised after 5 years was 2.5 (95% Confidence Interval: 2.1-3.0). For the Charnley prosthesis (n6,694), 2.9% were revised after 5 years (95% CI: 2.3-3.4). Using Cox regression to adjust for gender, age, type of cement and use of systemic antibiotic prophylaxis, the Charnley prosthesis was compared with the 9 other brands. The revision rate for the SpectrodlTH combination (Spectron acetabulum, ITH femur) (n 1,034) was only 0.35 (p 0.04) times that of the Charnley prostheses. The EliteKharnley combination (Elite acetabulum, Charnley femur) (n 507) and the Mirller Type prosthesis (n 11 6) showed poorer results with failure rates 2.3 (p 0.01) and 2.7 times (p 0.04) that of Charnley, respectively.

Although the overall results for cemented THRs in general were good, clinically important differences in revision rates were demonstrated among the cemented prosthesis brands. Our findings underline the need for careful evaluation of different total hip replacements.  相似文献   

6.
BACKGROUND: The results of total hip arthroplasty (THA) in young patients with rheumatoid arthritis (RA) have been reported in only a few studies. On a nationwide level, the outcome of THA in these patients is unknown. We evaluated the population-based survival of THA in patients under 55 years of age with RA and factors affecting the survival. PATIENTS: Between 1980 and 2003, 2,557 primary THAs performed for RA in patients less than 55 years of age were reported to the Finnish Arthroplasty Register. RESULTS: Proximally circumferentially porous-coated uncemented stems had a 15-year survival rate of 89% (95% CI 83-94) with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porouscoated uncemented stems implanted during the same period (RR 2.4; p < 0.001). In contrast, Cox regression analysis showed that the risk of cup revision was significantly higher for all uncemented cup concepts than for all-polyethylene cemented cups with any cup revision as endpoint. There were no significant differences in survival between the THR concepts. INTERPRETATIONS: Uncemented proximally circumferentially porous-coated stems and cemented all-poly-ethylene cups are currently the implants of choice for young patients with RA.  相似文献   

7.

Background and purpose

Reverse hybrid hip replacement uses a cemented all-polyethylene cup and an uncemented stem. Despite increasing use of this method in Scandinavia, there has been very little documentation of results. We have therefore analyzed the results from the Norwegian Arthroplasty Register (NAR), with up to 10 years of follow-up.

Patients and methods

The NAR has been collecting data on total hip replacement (THR) since 1987. Reverse hybrid hip replacements were used mainly from 2000. We extracted data on reverse hybrid THR from this year onward until December 31, 2009, and compared the results with those from cemented implants over the same period. Specific cup/stem combinations involving 100 cases or more were selected. In addition, only combinations that were taken into use in 2005 or earlier were included. 3,963 operations in 3,630 patients were included. We used the Kaplan-Meier method and Cox regression analysis for estimation of prosthesis survival and relative risk of revision. The main endpoint was revision for any cause, but we also performed specific analyses on different reasons for revision.

Results

We found equal survival to that from cemented THR at 5 years (cemented: 97.0% (95% CI: 96.8–97.2); reverse hybrid: 96.7% (96.0–97.4)) and at 7 years (cemented: 96.0% (95.7–96.2); reverse hybrid: 95.6% (94.4–96.7)). Adjusted relative risk of revision of the reverse hybrids was 1.1 (0.9–1.4). In patients under 60 years of age, we found similar survival of the 2 groups at 5 and 7 years, with an adjusted relative risk of revision of reverse hybrids of 0.9 (0.6–1.3) compared to cemented implants.

Interpretation

With a follow-up of up to 10 years, reverse hybrid THRs performed well, and similarly to all-cemented THRs from the same time period. The reverse hybrid method might therefore be an alternative to all-cemented THR. Longer follow-up time is needed to evaluate whether reverse hybrid hip replacement has any advantages over all-cemented THR.The reverse hybrid method (also known as “inverse hybrid”) uses a cemented all-polyethylene cup in combination with an uncemented stem. This method is partly based on good clinical results of cemented cups and of some uncemented stems in the Norwegian Arthroplasty Register (NAR) (Havelin et al. 2000a,b, Hallan et al. 2007). The register has also shown that some uncemented femoral stems may have better long–term results (> 10 years) than cemented stems in patients 60 years of age or younger. Based on these findings, the NAR suggested 10 years ago that the use of cemented cups in combination with uncemented stems might be justified in young patients (Havelin et al. 2000a). In the Swedish Hip Arthroplasty Register, the performance of uncemented THR was found to be inferior to that of cemented THR (Hailer et al. 2010). The authors of that study found that cemented cups performed better than uncemented cups and that uncemented femoral stems had better survival than cemented stems, with aseptic loosening as endpoint. In the Finnish Arthroplasty Registry, Mäkelä et al. (2010) found better long-term survival regarding aseptic loosening for the best performing types of cementless stems compared to the cemented reference group, in the age group 55–74 years.McNally et al. (2000) studied survival of the Furlong HA coated femoral stem in combination with a cemented ultra-high-density polyethylene cup at 10–11 years, and found values of 99% for the stem and 95% for the cup. Alho et al. (2000) reported results with cemented Lubinus cups and uncemented Furlong stems, and they also pointed out the possibility of using the principle of reverse hybrid arthroplasty. We are not aware of any other reports on the reverse hybrid method.In a reverse hybrid THR, an uncemented stem and a modular head are most often combined with a cemented cup of another name or from another company. Combining implants that are not designed to fit each other might theoretically lead to unexpected complications such as increased wear, loosening, or dislocation. This concern was raised by the NAR already in their report from 2005 (Norwegian Arthroplasty Register 2005). As the use of reverse hybrids is increasing, we decided to evaluate the short- to medium-term results with this concept and to compare them with those from all-cemented THRs, using data from the NAR.  相似文献   

8.
《The Journal of arthroplasty》2020,35(4):1042-1047
BackgroundThere is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years.MethodsClinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known.ResultsMean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher’s disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years–stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis.ConclusionThe Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.  相似文献   

9.
We have compared the survival of two hydroxyapatite (HA)-coated cups, 1208 Atoll hemispheric and 2641 Tropic threaded, with cemented Charnley all-polyethylene cups (16 021) using the Cox regression model. The Tropic cup used in combination with an alumina ceramic femoral head, had good results, similar to those of the Charnley cup. When used in combination with a stainless-steel head, however, the risk of revision beyond four years was increased 3.4 times for the Tropic cup compared with the Charnley cup (p < 0.001). Over the same period, the Atoll cup had an increased risk of revision of 3.8 times when used with the alumina heads (p < 0.001) and an increased risk of 6.1 times when used with stainless-steel heads (p < 0.001). Revision because of wear and osteolysis was more common with both types of HA-coated cup than with the Charnley cup. The rate of revision of the Atoll cup because of aseptic loosening was also increased. We found that HA-coated cups did not perform better than the Charnley cup.  相似文献   

10.
《Acta orthopaedica》2013,84(6):853-865
Background?The results of total hip arthroplasty (THA) in young patients with rheumatoid arthritis (RA) have been reported in only a few studies. On a nationwide level, the outcome of THA in these patients is unknown. We evaluated the population-based survival of THA in patients under 55 years of age with RA and factors affecting the survival.

Patients?Between 1980 and 2003, 2,557 primary THAs performed for RA in patients less than 55 years of age were reported to the Finnish Arthroplasty Register.

Results?Proximally circumferentially porous-coated uncemented stems had a 15-year survival rate of 89% (95% CI 83–94) with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porouscoated uncemented stems implanted during the same period (RR 2.4; p < 0.001). In contrast, Cox regression analysis showed that the risk of cup revision was significantly higher for all uncemented cup concepts than for all-polyethylene cemented cups with any cup revision as endpoint. There were no significant differences in survival between the THR concepts.

Interpretations?Uncemented proximally circumferentially porous-coated stems and cemented all-poly-ethylene cups are currently the implants of choice for young patients with RA.  相似文献   

11.

Background and purpose

We performed a randomized study to determine the migration patterns of the Spectron EF femoral stem and to compare them with those of the Charnley stem, which is regarded by many as the gold standard for comparison of implants due to its extensive documentation.

Patients and methods

150 patients with a mean age of 70 years were randomized, single-blinded, to receive either a cemented Charnley flanged 40 monoblock, stainless steel, vaquasheen surface femoral stem with a 22.2-mm head (n = 30) or a cemented Spectron EF modular, matte, straight, collared, cobalt-chrome femoral stem with a 28-mm femoral head and a roughened proximal third of the stem (n = 120). The patients were followed with repeated radiostereometric analysis for 2 years to assess migration.

Results

At 2 years, stem retroversion was 2.3° and 0.7° (p < 0.001) and posterior translation was 0.44 mm and 0.17 mm (p = 0.002) for the Charnley group (n = 26) and the Spectron EF group (n = 74), respectively. Subsidence was 0.26 mm for the Charnley and 0.20 mm for the Spectron EF (p = 0.5).

Interpretation

The Spectron EF femoral stem was more stable than the Charnley flanged 40 stem in our study when evaluated at 2 years. In a report from the Norwegian arthroplasty register, the Spectron EF stem had a higher revision rate due to aseptic loosening beyond 5 years than the Charnley. Initial stability is not invariably related to good long-term results. Our results emphasize the importance of prospective long-term follow-up of prosthetic implants in clinical trials and national registries and a stepwise introduction of implants.Femoral stem loosening in cemented total hip arthroplasty (THA) is a multifactorial process with different mechanisms (Gruen et al. 1979, Barrack 2000). Factors such as the material, design, and surface finish are of fundamental importance for the long-term performance of cemented femoral hip implants (Scheerlinck and Casteleyn 2006). The longevity of cemented femoral stems has been related to the quality, stability, and endurance of the bonding between stem and cement (Chang et al. 1998, Scheerlinck and Casteleyn 2006). Different femoral stem designs have been developed to obtain increased fixation at this interface, since debonding between the cement and stem is an important mechanism in the initiation of loosening (Jasty et al. 1991).The satin-finish Spectron femoral stem has been one of the best performing stems in the Swedish National Arthroplasty Register (Malchau et al. 2002). A modified, proximally roughened version of the Spectron stem, the Spectron EF (Smith and Nephew, Memphis, TN), was introduced in 1989 to enhance stem-cement bonding.The use of this implant gained increasing popularity, and in 2007 the Spectron EF stem used with the Reflection All-Poly acetabular cup (Smith and Nephew) was the most commonly used primary total hip prosthesis in Norway (Espehaug et al. 2009).The degree of migration during the first years after surgery has been shown to correlate with the long-term performance of joint prostheses (Kärrholm et al. 1994, Kobayashi et al. 1997). Radiostereometric analysis (RSA) allows the accurate measurement of implant movement and has been extensively used for measurement of the in vivo migration of implants (Kärrholm et al. 1997).An earlier prospective randomized study reported an increased revision rate of the Charnley stem compared to the satin-finished Spectron stem (Garellick et al. 1999). In the present randomized, controlled clinical trial we wanted to evaluate the early migration of the successor to this stem, the Spectron EF stem and to compare it to that of the Charnley stem using RSA. The null hypothesis was that the migration of the Spectron EF stem was equal to that of the Charnley prosthesis (DePuy International Ltd., Leeds, UK), which has the longest follow-up and the largest volume of documentation of implants used for primary total hip arthroplasty (Aamodt et al. 2004).  相似文献   

12.
《Acta orthopaedica》2013,84(6):559-565
Background and purpose The most common surgical approaches in total hip arthroplasty in Sweden are the posterior and the anterolateral transgluteal approach. Currently, however, there is insufficient evidence to prefer one over the other regarding risk of subsequent surgery.

Patients and methods We searched the Swedish Hip Arthroplasty Register between the years 1992 and 2009 to compare the posterior and anterolateral transgluteal approach regarding risk of revision in the 3 most common all-cemented hip prosthesis designs in Sweden. 90,662 total hip replacements met the inclusion criteria. We used Cox regression analysis for estimation of prosthesis survival and relative risk of revision due to dislocation, infection, or aseptic loosening.

Results Our results show that for the Lubinus SPII prosthesis and the Spectron EF Primary prosthesis, the anterolateral transgluteal approach gave an increased risk of revision due to aseptic loosening (relative risk (RR) = 1.3, 95% CI: 1.0–1.6 and RR = 1.6, CI: 1.0–2.5) but a reduced risk of revision due to dislocation (RR = 0.7, CI: 0.5–0.8 and RR = 0.3, CI: 0.1–0.4). For the Exeter Polished prosthesis, the surgical approach did not affect the outcome for dislocation or aseptic loosening. The surgical approach had no influence on the risk of revision due to infection in any of these designs.

Interpretation This observational study shows that the surgical approach affected the risk of revision due to aseptic loosening and dislocation for 2 of the most commonly used cemented implants in Sweden. Further studies are needed to determine whether these results are generalizable to other implants and to uncemented fixation.  相似文献   

13.
《The Journal of arthroplasty》2022,37(5):897-904.e1
BackgroundTotal hip arthroplasty (THA) for avascular necrosis (AVN) or inflammatory arthritis (IA) comes with a relatively high risk of aseptic stem loosening, especially in young patients. There are limited long-term data on the survivorship of polished, tapered, cemented stems in this population. We therefore performed a single-center retrospective study investigating the survival of this particular stem type in young patients with AVN or IA.MethodsAll patients aged ≤35 years who had received a THA for AVN or IA operated on by the senior author between 1990 and 2010 at the University Hospitals Leuven were identified. In total, 85 THAs in 62 patients were included. Primary endpoint was revision of the femoral component for aseptic loosening. Secondary endpoints were revision of the acetabular component for aseptic loosening, revision for other reasons, and the presence of radiolucencies around the components.ResultsThe mean follow-up for the entire cohort was 18.0 ± 5.3 years (range 8.0-28.9). Taking revision for aseptic loosening as endpoint, the survival of cemented stems was 100% after 15 years and 95.1% after 20 years. Survival of uncemented cups (91.3%) was significantly better than survival of cemented cups (50.3%) after 20 years of follow-up for aseptic loosening. Taking revision for any reason as endpoint, the survival of THAs with uncemented and cemented cups was 90% and 43.1% at 20 years respectively. Radiolucencies developed in the cement mantles around 11 of the 81 nonrevised stems, mainly in zones 1 and 7.ConclusionIn this cohort of young patients with high-risk profiles for aseptic stem loosening, polished, tapered, cemented stems showed excellent long-term survival rates and they therefore remain a viable alternative to uncemented stem designs.  相似文献   

14.
BackgroundInstability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability.MethodsThis is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; Serf, Décines-Charpieu, France) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation.ResultsWith a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients.ConclusionThe use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years.  相似文献   

15.
We postulated that certain patient characteristics have different effects on early THA component loosening. With two matched case-control studies we assessed 3,028 cups and 5,224 stems. Loosening was defined using signs of mechanical component failure on routine follow-up radiographs or revision for aseptic loosening. Women and men had similar cup-loosening odds, but women had lower odds for stem loosening (p < 0.0001). Odds for cup loosening decreased by 2.1% per additional year of age (p = 0.0004), those for stem loosening by 2.4% (p < 0.0001). Each additional kilogram of weight decreased cup loosening odds by 1.3% (p = 0.0051). Each additional unit of BMI increased stem loosening odds (p = 0.0109). Charnley classes B and C were protective factors against loosening of both components. There were no risk differences for the various main diagnoses. Certain patient characteristics differently affected early cup and stem loosening, although some characteristics had the same protective or harmful effect on component survival.  相似文献   

16.
The uncemented Bi-Contact total hip arthroplasty   总被引:1,自引:0,他引:1  
We reviewed a consecutive series of 153 uncemented Bi-Contact (Aesculap, Tuttlingen, Germany) total hip arthroplasties (THAs) in 138 patients who had been followed for at least 5 years (mean, 6.8 years; range, 5-9 years). The Bi-Contact uncemented THA consists of a straight femoral stem made of titanium alloy. The proximal portion of the stem is titanium plasma-sprayed. The cup is press-fit with or without hydroxyapatite coating with a facility for anchoring screws with a snap-fit polyethylene liner. The mean age of the patients was 70.8 years (range, 41-94 years). The mean preoperative Harris hip score of 41 (range, 20-80) improved postoperatively to a mean of 92 (range, 56-96). Three acetabular cups were revised for aseptic loosening, and 1 cup was revised for recurrent dislocation. To date, none of the stems have been revised for aseptic loosening. Radiographic evaluation of the remaining 149 hips revealed that the acetabular cup was stable in 146 hips and possibly unstable in the remaining 3 cases with nonprogressive osteolysis behind the cup. None of the stems showed any evidence of instability. Using the recommendation of revision as the endpoint, the cumulative survival for the prosthesis was 97.3% at a mean follow-up of 6.8 years (95% confidence interval, 95.9-99.4), with stem survival of 100%. In the medium-term, these results are comparable to cemented primary THA and justify the continued use of this prosthesis.  相似文献   

17.
Background The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA).

Patients and methods Using the Danish Hip Arthroplasty Registry (DHR), we identified patients less than 70 years old who had undergone uncemented primary THA during 1997-2005. 4,125 HA-coated and 7,737 non-HA-coated cups and 3,158 HA-coated and 4,749 non-HA-coated stems were available for analysis. The mean follow-up time was 3.4 years for cups and 3.2 years for stems. We estimated the relative risk (RR) of revision due to aseptic loosening or any cause, and adjusted for possible confounders (age, sex, fixation of opposite implant part, and diagnosis for primary THA) using multivariate Cox regression analysis.

Results The adjusted RRs for revision of HA-coated cups and stems due to aseptic loosening were 0.89 (95%CI: 0.37-2.2) and 0.71 (95%CI: 0.27-1.9) with up to 9 years of follow-up, compared to non-HA-coated implants. When taking all causes of revision into consideration, the risk estimates were 0.85 (95%CI: 0.68-1.1) and 0.81 (95%CI: 0.61-1.1) for HA-coated cups and stems, respectively.

Interpretation In this medium-term follow-up study, the use of HA-coated implants was not associated with any clearly reduced overall risk of revision compared to non-HA-coated implants.  相似文献   

18.
We studied prospectively 382 cementless (Zweymiiller stem) and hybrid (cemented stem) primary total hip replacements and used a cementless grit-blasted titanium alloy threaded cup. After a median 5 (0.2-12)-year follow-up, 1 cup was exchanged, 2 cups were removed for deep sepsis, and 3 cups showed definite loosening; of these, 2 subsequently required revision. Actuarial calculation methods indicated a 10-year survivorship of 99% with cup retrieval for any cause (clinical failure), definite cup-loosening (radiographic failure), and revision for aseptic cup-loosening as endpoints. These intermediate results exceed those from smooth-surfaced screw rings and compare favorably with those from cemented cups and cementless, press-fit, metal-backed cups.  相似文献   

19.
At the authors' hospital, 410 primary total hip replacements were performed on 372 patients between September 1, 1985, and May 31, 1989. All hips were assigned randomly to receive a Charnley prosthesis with an ogee flanged cup or a Spectron prosthesis with a metal backed cup. Eleven-year survivor analysis, using revision as the end point definition of failure, revealed a survival rate of 93.2% +/- 5.8% for the Charnley replacement and 95.9% +/- 3.0% for the Spectron. If each component of the systems was analyzed (concerning aseptic loosening), the ogee cup and the Spectron stem had 100% survival. The survivorship for all 410 hips was 94.5% +/- 3.4%. If the end point definition of failure was expanded to include patient dissatisfaction, the survival rate decreased to 86.3% +/- 4.9%. These survival rates were compared with the rates obtained by the Swedish National Hip Registry. The national cohort included all patients in Sweden who were treated surgically with a Charnley (14,053 patients) or Spectron (metal backed cup) prosthesis (726 patients) between September 1, 1985, and May 31, 1989. Eleven-year survivor analysis revealed a national survival rate of 92.1% +/- 0.7% for the Charnley replacement and 88.6% +/- 6.1% for the Spectron. The analyses from the Swedish Registry are based on more than 160,000 primary operations and 11,500 revisions. Despite the enormous amount of data, there are drawbacks, and registries never can replace the prospective, randomized trial. One reason is the Swedish National Registry is unable to discriminate between the individual cup and stem components when analyzing the cause of revision, and no clinical or radiographic information is collected. A potential drawback for the randomized trial is performance bias because surgeons from specialized centers might perform better than the general orthopaedic surgeon.  相似文献   

20.
Background and purpose — According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65–74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously.

Patients and methods — We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material.

Results — Spectron EF THA (89.9% (CI: 89.3–90.5)) and Elite THA (89.8% (CI: 89.0–90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5–95.9), MS 30 (96.6%, CI: 95.8–97.4), and C-stem THA (95.8%, CI: 94.8–96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR)?=?0.77, CI: 0.73–0.81), Müller (RR =0.83, CI: 0.70–0.99), MS-30 (RR =0.73, CI: 0.63–0.86), C-stem (RR =0.70, CI: 0.55–0.90), and Exeter Duration THA (RR =0.84, CI: 0.77–0.90) had a lower risk of revision than Charnley THA, the reference implant.

Interpretation — The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Müller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival.  相似文献   