首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 518 毫秒
1.
We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results (n = 58) than either culture (n = 55) or the Directigen immunoassay (n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted "gold standard," bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR (n = 7) or the Directigen method (n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant (P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time ( approximately 1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).  相似文献   

2.
Varicella-zoster virus (VZV) causes vesicular dermal lesions which are clinically evident as varicella (primary infection) or zoster (reactivated) diseases. The LightCycler system (Roche Molecular Biochemicals) is a newly developed commercially available system designed to rapidly perform PCR with real-time detection of PCR products using a fluorescence resonance energy transfer. We compared the detection of VZV from dermal specimens by shell vial cell culture (MRC-5) and by LightCycler PCR. Of 253 specimens, VZV was detected in 23 (9.1%) by shell vial cell cultures and 44 (17.4%) by LightCycler PCR directed to a nucleic acid target sequence in gene 28. Twenty-one of 44 (47.7%) specimens were exclusively positive by LightCycler PCR; the shell vial cell culture assay was never positive when DNA amplification was negative (specificity, 100%). VZV DNA was detected in 39 of 44 (88.6%) specimens positive during cycles 10 through 30 of the LightCycler PCR. These VZV DNA-positive specimens (cycles 10 to 30) and 5 of 11 other PCR positive specimens (cycles 31 to 36) were confirmed by another LightCycler PCR directed to another (gene 29) target of the viral genome. For routine laboratory practice, all specimens yielding amplified DNA to the VZV gene 28 target can be considered positive results. The increased sensitivity (91%) of the LightCycler PCR for detection of VZV, rapid turnaround time for reporting results, virtual elimination of amplicon carryover contamination, and equivalent costs compared to shell vial cell culture for detection of VZV indicate the need for implementation of this technology for routine laboratory diagnosis of this viral infection.  相似文献   

3.
We evaluated 2 methods, a LightCycler PCR assay and pyrosequencing for the detection of the JC polyoma virus (JCV) in fixed brain tissue of 10 patients with and 3 control patients without progressive multifocal leukoencephalopathy (PML). Nucleic acid extraction was performed after deparaffinization and proteinase K digestion. The LightCycler assay differentiates the BK virus (BKV), JCV, and SV40 using melt curve analysis. Conventional PCR was used with the same primers to generate products for pyrosequencing. Two sequencing primers were used that differentiate the polyoma viruses. Seven of 11 biopsies (1 patient had 2 biopsies) with PML were positive for JCV by real-time PCR and/or PCR/pyrosequencing. Three of 4 remaining biopsies were positive by real-time PCR but had melting points between JCV and SV40. The 4 specimens that were negative or atypical by LightCycler PCR were positive by traditional PCR, but 1 had an amplicon of lower molecular weight by gel electrophoresis. These were shown to represent JCV by at least 1 of the 2 pyrosequencing primers. The biopsies from patients without PML were PCR negative. Both the LightCycler and pyrosequencing assays are useful for confirming JCV in brain biopsies from patients with PML, but variant JCVs may require supplementary methods to confirm JCV infection.  相似文献   

4.
We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method (P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles (P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) (P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.  相似文献   

5.
We compared the performance characteristics of a real-time PCR method, the LightCycler vanA/vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 microg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 microg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 microg/ml (n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 microg/ml (n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 microg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 microg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (approximately 3.5 versus > or =72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.  相似文献   

6.
Human polyomaviruses JC and BK may cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy and hemorrhagic cystitis. Molecular detection by PCR is recognized as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, a real-time PCR assay using the LightCycler platform was evaluated and compared to an "in-house" PCR assay using a conventional detection method. A total of 122 urine specimens were tested, and human polyomavirus was detected in 49 specimens (40%) by both conventional PCR and LightCycler PCR. The remaining 73 specimens (60%) were found negative by both assays. For 46 of the 49 positive specimens, LightCycler PCR and conventional PCR identified the same polyomavirus type. These samples included 30 samples with JC virus (JCV), 14 samples with BK virus (BKV), and 2 samples in which both viruses were detected. In the remaining three samples, both JCV and BKV were detected by the conventional assay, but only JCV was detected by the LightCycler assay. The results of this study show that the LightCycler PCR assay displays sensitivity and specificity similar to those of a conventional PCR assay. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid detection and differentiation of JCV and BKV in the clinical laboratory.  相似文献   

7.
To improve the diagnosis of invasive aspergillosis (IA), we developed a LightCycler PCR assay targeted to Aspergillus fumigatus and A. flavus mitochondrial DNA. To avoid contamination, fully automated nucleic acid extraction with the MagNA Pure LC apparatus was used. The linearity of the results was achieved over a 6-log range of input A. fumigatus DNA, from 0.3 ng to 3 fg/10 microl of water. We retrospectively compared the LightCycler PCR and an enzyme-linked immunosorbent assay for the detection of galactomannan (GM) in serum from 14 patients with IA. The GM assay was more frequently positive (57 of 109; 52%) than the PCR assay (49 of 109; 45%). The LightCycler PCR assay, combined with automated DNA extraction, could be used in association with the GM assay to improve the reliability of IA diagnosis.  相似文献   

8.
BACKGROUND: In recent years polymerase chain reaction (PCR) has proven to be a highly sensitive and specific method for the diagnosis of herpes simplex virus (HSV) infections. The advent of real-time HSV PCR protocols now enables rapid result turnaround times with minimal hands-on time. OBJECTIVES: In this study, we developed a real-time duplex PCR assay (HSVgD-dPCR) comprising of HSV and internal control PCR reactions. STUDY DESIGN: Using the LightCycler, the HSVgD-dPCR targeted the HSV glycoprotein D gene and HSV typing was performed by melting curve analysis. The internal control PCR reaction targeted sequences of the DNA of the human endogenous retrovirus (ERV-3). In total, 300 swab specimens, from patients with suspected HSV infection, were tested by the HSVgD-dPCR assay. The results were then compared to the results obtained by another HSV LightCycler assay, which utilized published primer and probe sequences targeting the HSV DNA polymerase gene (Dpol-HSV-LCPCR). RESULTS: Overall, 91 (30.3%) specimens were positive and 204 (68.0%) specimens were negative for HSV by both LightCycler assays. In addition, four (1.3%) specimens were positive by Dpol-HSV-LCPCR and negative by HSVgD-dPCR, whereas one (0.3%) specimen was positive by HSVgD-dPCR and negative by Dpol-HSV-LCPCR. The presence of HSV in these five specimens was confirmed by conventional PCR. Melting curve analysis by the HSVgD-dPCR assay enabled all HSV positive specimens to be typed, whereas sequence variation prevented three HSV positive specimens from being typed by the Dpol-HSV-LCPCR. Using the ERV-3 PCR, 5% specimens were found to contain inhibitory substances. CONCLUSIONS: By developing the HSVgD-dPCR we have enhanced the diagnostic utility of real-time detection of HSV by incorporating an internal control reaction and by accurately typing a greater proportion of HSV positive specimens.  相似文献   

9.
Real-time PCR is a useful tool for rapid detection of viral genomic DNA. However, there are many types of real-time PCR, and this variation may induce different results. The sensitivity of two different real-time PCR assays was evaluated for the detection of the varicella-zoster virus (VZV) genome: LightCycler PCR and TaqMan PCR. Auricular skin cells and saliva were sampled from 201 patients with facial nerve paralysis. A hundred and seventy-one of these patients were diagnosed clinically with Bell's palsy, and the remaining 30 with Ramsay Hunt syndrome. In 30 specimens obtained from Ramsay Hunt syndrome patients, VZV DNA was detected in 26 skin and 3 saliva specimens using the LightCycler PCR, while 28 skin and 9 saliva specimens were positive using the TaqMan PCR. None of the patients with Bell's palsy were positive for VZV by the LightCycler PCR, whereas five of these patients were positive by the TaqMan PCR. The TaqMan PCR assay has a better sensitivity compared to the LightCycler PCR for the detection of VZV genome from patients with facial palsy. Further study is required to develop a more sensitive real-time PCR.  相似文献   

10.
Mycoplasma genitalium is known to cause nonchlamydial, nongonococcal urethritis in men and to be associated with pelvic inflammatory disease in women. Specific and sensitive PCR methods are needed for diagnosis of this bacterium because it is very difficult to culture from patient samples. To determine the bacterial load in patients' specimens, a quantitative real-time LightCycler PCR was developed. The housekeeping gene gap encoding glyceraldehyde-3-phosphate dehydrogenase was chosen as the target gene. The assay could consistently detect five genome copies per reaction. To evaluate the PCR, we tested 246 selected urethral swab samples from men attending a clinic for sexually transmitted diseases. Eighty-two of the samples were found positive for M. genitalium by a conventional 16S rRNA gene PCR assay, whereas 164 samples were randomly chosen among those tested negative. Of the positive samples, 78 (95.1%) were found positive, whereas 6 (3.7%) of the negatives were found positive by the LightCycler assay. The patient samples were also tested with a quantitative TaqMan assay, and the bacterial load was compared to the LightCycler results. A good linear correlation between the LightCycler and the TaqMan assays was found with a correlation coefficient of 0.89 and a slope of 0.99. Significantly more M. genitalium-positive men had urethritis, discharge, and dysuria than had M. genitalium-negative men. The M. genitalium DNA load in samples from patients with urethritis was significantly higher than in samples from those without (61 and 2.9 copies/microl, respectively [P = 0.0005]). This assay may prove useful in the monitoring of treatment and for optimizing sample preparation methods.  相似文献   

11.
Herpes simplex virus (HSV) causes several clinical manifestations in both normal and immunocompromised hosts; this agent is the most frequently detected virus in diagnostic laboratories. Recovery of the virus in cell culture is considered the "gold standard" for detection of this virus from sources other than cerebrospinal fluid. LightCycler is a newly developed, commercially available system designed to rapidly perform PCR, with real-time detection of PCR products by a fluorescence resonance energy transfer assay. We compared the detection of HSV for 200 specimens (number of genital specimens, 160; number of dermal specimens, 38; number of ocular specimens, 2) by shell vial cell cultures (MRC-5) and by LightCycler PCR. Of a total of 88 (44%) HSV strains detected, 69 (78%) were detected by both shell vial cell cultures and LightCycler PCR (DNA polymerase target). A total of 19 (22%) specimens were detected exclusively by LightCycler PCR. No specimens were positive by the shell vial assay only. All 19 discrepant samples had HSV DNA detected by an independent PCR directed to the thymidine kinase gene of the virus. The melting curve analysis feature of the LightCycler instrument identified identical genotype results for HSV type 1 (HSV-1) and HSV-2 from 84 of 88 (96%) positive samples. Specimens can be extracted, target HSV DNA can be amplified, and HSV PCR products can be identified by genotype within 2 h after receipt of specimen into the laboratory. The increased level of accurate identification (all 88 positive samples) compared with that of shell vial cell culture (69 of 88 samples identified as positive) and the agreement of LightCycler PCR results with all shell vial positive results indicate the potential for routine implementation of this technology for laboratory diagnosis of HSV infections.  相似文献   

12.
Real-time PCR and fluorescence in situ hybridization (FISH) were evaluated as rapid methods for the diagnosis of bacterial meningitis and compared to standard diagnostic procedures. For PCR, a LightCycler approach was chosen, implementing eubacterial and specific PCR assays for the most relevant bacteria. For FISH, a similar probe set containing eubacterial and specific probes was composed of published and newly designed probes. Both methods were evaluated by use of cerebrospinal fluid (CSF) samples from patients with suspected bacterial meningitis. For all microscopy- and culture-positive samples (n = 28), the eubacterial PCR was positive. In addition, all identifiable pathogens were detected with specific PCR assays, according to an algorithm based on the Gram stain. The FISH method detected the pathogen in 13 of 18 positive samples. While the FISH method remained negative for all microscopy- and culture-negative samples (n = 113), the eubacterial PCR was positive for five of these samples. Sequencing of the amplicon revealed the presence of Neisseria meningitidis, Streptococcus agalactiae, and Haemophilus influenzae in three of these five samples. In addition, samples with discordant results by culture and microscopy were successfully investigated by PCR (10 samples) and FISH (5 samples). In conclusion, PCR is a highly sensitive tool for rapid diagnosis of bacterial meningitis. FISH is less sensitive but is useful for the identification of CSF samples showing bacteria in the Gram stain. Based on our results, an approach for laboratory diagnosis of meningitis including PCR and FISH is discussed.  相似文献   

13.
Tuberculosis in immunocompromised patients is often caused by Mycobacterial species other than Mycobacterium tuberculosis. Thus, detection of and differentiation between M. tuberculosis and nontuberculosis species is necessary for diagnosis of disease in these patients. Furthermore, when tissue changes show granulomatous inflammation, quick confirmation testing for mycobacterial infection is needed for conclusive diagnosis. The aim of this study was to validate the utility of a real-time polymerase chain reaction (PCR) assay in conjunction with the MagNA Pure LC automated extraction system for the detection of mycobacterial DNA from formalin-fixed, paraffin-embedded specimens. A total of 46 archived, paraffin-embedded, fixed specimens showing granulomatous inflammation were studied for mycobacterial infection by real-time PCR. Bacterial DNA was extracted and isolated using the MagNA Pure extraction system. Real-time PCR was performed on the LightCycler using the Artus Real Art Mycob Diff ASR kit from Qiagen. Thirteen of the 46 patient specimens were positive for mycobacterial infection by acid-fast bacilli (AFB) stain. Of the13 reported positive by AFB stain, 12 where positive by real-time PCR. All 13 specimens reported positive by AFB were sent for culture confirmation. Eleven of 13 were returned positive by culture. Specimens reported as negative by culture and positive by real-time PCR were confirmed positive by a second PCR method from another reference laboratory. We believe that these studies are beneficial in the differential diagnosis of mycobacterial infection from fixed tissue specimens where tuberculosis might not have been clinically initially suspected and when specimens are not suitable for microbiologic examination.  相似文献   

14.
Our objective was to evaluate the feasibility of a molecular assay based on a real-time PCR technique, carried out with a LightCycler instrument (Roche Biochemicals), to identify Mycobacterium tuberculosis bacilli and to detect rifampin and isoniazid resistance in DNA extracts from sputum samples. We studied three genes: rpoB, which is associated with rifampin resistance, and katG and inhA, which are associated with isoniazid resistance. A total of 205 sputum samples collected from 108 patients diagnosed with pulmonary tuberculosis with positive auramine-rhodamine-staining (AR) sputum samples, were tested. The sensitivities of the LightCycler PCR assay for the positive AR specimens was 97.5% (200 of 205) for rpoB and inhA genes and 96.5% (198 of 205) for the katG gene. For the total number of patients tested, the sensitivity was 100% (108 of 108 patients) for rifampin, whereas the sensitivity was 98.1% (106 of 108 patients) for isoniazid. Full agreement was found with the Bactec MGIT 960 method and the genotype inferred from the LightCycler data for rifampin. The phenotypic method for isoniazid reported 13 resistant strains (> or = 0.1 microg/ml). In seven (53.8%) strains there was a concordance between both methods, but we found that six (46.2%) strains reported as resistant by the phenotypic method were determined to be susceptible by real-time PCR. For the 75 strains reported as susceptible by the phenotypic method, the concordance with the LightCycler data was 100%. Our results demonstrate that rifampin-resistant M. tuberculosis could be detected in DNA extracted from auramine-rhodamine-positive sputum samples in a single-tube assay that took less than 3 h to perform for a collection of auramine-rhodamine-positive specimens obtained from patients with culture-documented pulmonary tuberculosis. Similarly, this occurs in half of the isoniazid-resistant M. tuberculosis DNA extracted from auramine-rhodamine-positive specimens.  相似文献   

15.
A LightCycler and two TaqMan real-time PCR assays were evaluated against an older PCR with liquid-phase hybridization method for the detection of enterovirus RNA in 74 patient samples. The two-step LightCycler and the two-step TaqMan formats correlated well with each other (r(2) = 0.90) and were equally sensitive compared to the liquid-phase hybridization method, whereas the one-step recombinant Tth DNA polymerase format was rather insensitive, detecting enterovirus RNA in only about one-half of those patient samples previously positive by liquid-phase hybridization. The two-step TaqMan method was optimized utilizing 10 micro l of cDNA and demonstrated the highest degree of analytical sensitivity among the methods evaluated in our study, being able to reproducibly quantify down to 510 copies of enteroviral RNA/ml of cerebrospinal fluid. This new assay can be performed in 4 h, is much less labor intensive, and showed less cross-reactivity with rhinovirus than the liquid-phase hybridization assay. Thus, the two-step TaqMan assay should prove useful in the diagnosis of enteroviral meningitis versus bacterial meningitis, thereby resulting in timely and appropriate clinical management that can amount to significant cost savings to the patient and health care system.  相似文献   

16.
The results for a real-time PCR assay, using the LightCycler Strep B analyte-specific reagents (Roche Diagnostics Corporation, Indianapolis, Ind.), were compared to a direct plate method combined with a broth enrichment culture method for detection of group B streptococcus colonization in pregnant women. Two separate evaluations were conducted using two different automated nucleic extraction instruments, the MagNA Pure LC instrument (Roche Diagnostics Corporation) and the lower-capacity MagNA Pure Compact instrument (Roche Diagnostics Corporation). The sensitivities, specificities, and positive and negative predictive values for the different evaluation methods were as follow: for the LightCycler Strep B assay with MagNA Pure LC, 100, 97, 90, and 100%, respectively; for the LightCycler Strep B assay with MagNA Pure Compact, 92.5, 99, 97, and 97.5%, respectively. The LightCycler Strep B assay combined with either MagNA Pure LC or MagNA Pure Compact extraction is a suitable method for detecting group B streptococcus colonization in pregnant women. An advantage of the LightCycler assay over culture is the considerably reduced turnaround time for results.  相似文献   

17.
We have evaluated a real-time PCR procedure based on the LightCycler technology for rapid detection of herpes simplex virus (HSV) in genital lesions. Two sets of primers, corresponding to the thymidine kinase and DNA polymerase regions, were used for the amplification reactions in separate capillaries containing the SYBR Green I dye as detection signal. In 28 of 118 samples (24%), HSV was isolated by conventional cell culture. All cell culture-positive samples were also positive by real-time PCR. Six additional cell culture-negative samples were positive by PCR with both sets of primers. Total processing time was less than 3 h. Real-time PCR using SYBR Green I as detection signal is a sensitive procedure for the rapid diagnosis of HSV in genital lesions.  相似文献   

18.
PCR-based methods have advantages over traditional microscopic methods for the diagnosis of malaria, especially in cases of low parasitemia and mixed infections. However, current PCR-based assays are often labor-intensive and not readily quantifiable and have the potential for contamination due to a requirement for postamplification sample handling. Real-time PCR can address these limitations. This study evaluated the performance characteristics of a commercial malaria real-time PCR assay (RealArt Malaria LC Assay; Artus GmbH, Hamburg, Germany) on the LightCycler platform for the detection of malaria parasites in 259 febrile returned travelers. Compared to nested PCR as the reference standard, the real-time assay had a sensitivity of 99.5%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 99.6% for the detection of malaria. Our results indicate that the RealArt assay is a rapid (<45 min), sensitive, and specific method for the detection of malaria in returned travelers.  相似文献   

19.
BACKGROUND: The diagnosis of hepatitis B virus (HBV) has until recently been based on traditional serologic methods targeting viral antigens and antibodies to viral proteins. The development of molecular methods allowing for the quantitation of HBV DNA is proving clinically valuable for monitoring therapy and detecting early treatment failures. OBJECTIVES: Here we report a new real-time (LightCycler) quantitative PCR for the detection of HBV DNA based on sequence specific hybridisation probes (designed in-house), targeting the HBV surface antigen. STUDY DESIGN: The assay was evaluated using a 10-fold dilution series of standard HBV DNA [Eurohep standard reference 1, genotype A, HBsAg subtype adw with a unitage of 10(6) WHO. i.u./ml] and 89 clinical serum samples. The performance was measured against a quantified standard HBV DNA working reagent (NIBSC code 98/780) and the sensitivity compared with our conventional thermal-block PCR. RESULTS AND CONCLUSION: Real-time PCR detected HBV DNA in 45% (40/89) and thermal-block PCR in 16% (14/75) of clinical samples. Results for 26 samples were below the detection limit of the thermal-block PCR but could be quantified by real-time (LightCycler) PCR. The LightCycler assay was at least 5 logs more sensitive than thermal-block PCR and could detect HBV in a linear range between 5 and 10(7) i.u. per reaction. The broad generic nature of the PCR primers coupled with the enhanced sensitivity and specificity of the fluorescent hybridisation probes makes this assay potentially valuable for both routine diagnostic and epidemiological work.  相似文献   

20.
We have established a method of quantitative detection and rapid identification of human adenoviruses (hAdVs). Using LightCycler PCR with a primer set, we were able to amplify 554 bp of the hexon gene from each of 51 prototype strains of hAdVs. The sensitivity of LightCycler PCR was 10 copies of hAdV DNA/reaction. When LightCycler PCR was performed using a set of primers, hAdV was positive for 74.4% (99 of 133) of conjunctivitis patients and for 27.3% (81 of 297) of respiratory infection patients. We also attempted to measure hAdV in the potentially contaminated eye drops used by patients, detecting 5.4 x 10(2) to 1.6 x 10(6) copies/ml of hAdV. We determined the 350-bp nucleotide sequence of the amplified hexon gene and compared it with the sequences of the 51 prototype strains. Phylogenetic analysis based on 350 bp of the hexon gene identified 99 positive conjunctival swabs as 24 cases of AdV type 3 (AdV-3), 14 cases of AdV-4, 1 case of AdV-8, 19 cases of AdV-19a, and 41 cases of AdV-37. The 81 sequences from pharyngeal or nasal mucus swabs were identified as 29 cases of AdV-2, 18 cases of AdV-1, 18 cases of AdV-5, 12 cases of AdV-4, 2 cases of AdV-37, 1 case of AdV-3, and 1 case of AdV-6. LightCycler PCR followed by phylogenetic analysis provides an effective tool for the rapid identification of hAdVs and for studying molecular epidemiology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号