首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Aim

To date, no data are available on the use of PET/CT for preoperative staging of gastric cancer. We attempted to evaluate the value of PET/CT for preoperative staging of advanced gastric cancer, and to compare the use of PET/CT with contrast-enhanced CT (CECT).

Materials and methods

We analyzed PET/CT of 78 patients with surgically proven advanced gastric cancer who had undergone preoperative CECT. Qualitative analysis was conducted by assessing the presence of primary tumors and metastases with PET/CT and CECT.

Results

Among 71 patients who underwent a gastrectomy, 69 primary tumors (93%) were diagnosed by PET/CT, while 64 primary tumors (90%) were detected by CECT (p = 0.55). For regional lymph node metastasis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of PET/CT vs. CECT were 41% vs. 25% (p = 0.00019), 100% vs. 92% (p = 0.31), 100% vs. 98% (p = 0.46), 26% vs. 42% (p = 0.14), and 51% vs. 72% (p = 0.00089), respectively.

Conclusion

Overall, PET/CT showed comparable diagnostic performance to CECT in diagnosing primary tumors and regional lymph node metastases, though PET/CT was inferior to CECT for the sensitivity and accuracy in diagnosing regional lymph node metastases. Nevertheless, PET/CT would be useful when CECT findings were equivocal due to its high positive predictability.  相似文献   

2.

Purpose

The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT.

Materials and methods

A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A.

Results

Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05).

Conclusion

Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.  相似文献   

3.

Purpose

The purpose of the study was to investigate the optimal scanning protocol of 64-slice CT angiography for assessment of coronary artery stents based on a phantom study.

Materials and methods

Coronary stents with a diameter of 2.5 mm was implanted in thin plastic tubes with an inner diameter of 3.0 mm to simulate a coronary artery. The tubes were filled with iodinated contrast medium diluted to 178 HU, closed at both ends and positioned in a plastic container filled with vegetable oil (−70 to −100 HU). A series of scans were performed with a 64-slice CT scanner with the following protocols: section thickness: 0.67 mm, 1.0 mm, 1.5 mm, 2.0 mm, pitch value: 0.2, 0.3, 0.5 and reconstruction interval of 50% overlap of the section thickness. 2D axial and multiplanar reformatted images were generated to assess the visibility of stent lumen, while virtual intravascular endoscopy (VIE) was reconstructed to evaluate the artery wall and stent surface.

Results

Our results showed that a scanning protocol of 1.0 mm slice thickness with a pitch of 0.3 produced acceptable images with best demonstration of the intrastent lumen and stent surface with minimal image noise or artifacts. In contrast, submillimeter scans with 0.67 mm resulted in moderate artifacts which affected visualization of the coronary lumen, in addition to the increased noise. When the section thickness increased to 1.5 mm and 2.0 mm, visualization of the artery wall and stent surface was compromised, although the intrastent lumen was still visible.

Conclusion

Our in vitro study suggested that a scanning protocol of 1.0 mm section thickness with pitch of 0.3 is the optimal protocol for evaluation of coronary artery stents as it allows generation of acceptable images with better visualization of stent lumen, stent surface and coronary artery wall.  相似文献   

4.

Introduction and aim

Ovarian carcinoma (OC) is a common cancer in the Western Countries, and an important cause of death in patients suffering with gynaecologic malignancies. The majority of patients present with advanced disease at the time of diagnosis. Treatment with debulking surgery followed by chemotherapy is the standard approach while chemotherapy is contemplated when surgery is not possible. A correct pre-operative staging is important to ensure a most appropriate management. Laparoscopy (LPS) is the standard diagnostic tool for the assessment of intraperitoneal infiltration but is invasive and requires general anaesthesia. FDG-PET/CT is increasingly used for staging different types of cancer, and the aim of this study is to assess the value of FDG-PET/CT in staging advanced OC and its sensitivity to detect lesions in different quadrants of the abdominal-pelvic area compared to laparoscopy.

Materials and methods

From September 2004 till April 2008, 40 patients with high suspicion of OC were referred to our hospital for diagnostic LPS to explore the possibility of optimal debulking surgery. Those who were not suitable for surgery were referred for chemotherapy. Before chemotherapy, the patients underwent an FDG-PET/CT scan. The findings in 9 quadrants of abdominal-pelvic area (total 360 quadrants) for PET/CT and LPS were recorded and compared.

Results

In 14/360 areas (3.8%), surgical evaluation was not possible because of presence of adhesions, thus the number of areas explored by laparoscopy was 346. Tumour was found in 308 quadrants (38 quadrants free of disease). PET/CT was positive in all 40 patients with true negative results in 26/346 quadrants (7.5%), and true positives results in 243/346 quadrants (70.2%). False positive and negative PET/CT results were found in 12/346 and 65/346 quadrants, respectively. False positive PET/CT findings were evenly present in all quadrants. False negative PET/CT findings were present in 31/109 (28.4%) upper abdominal quadrants (epigastrium and diaphragmatic areas). Final analysis showed a sensitivity and specificity for PET/TC of 78.9 and 68.4% respectively with a positive predictive value of 95.3%. A significant difference was noted between mean SUVmax associated with lesions smaller or larger than 0.5 cm (p = 0.006).

Conclusion

Our results suggest that PET/CT may prove a useful tool for pre-surgical staging of ovarian cancer with a sensitivity and specificity of 78 and 68%, respectively. However, it may be used in combination with laparoscopy for better results. PET/CT showed an adequate correlation between SUVmax values and laparoscopy findings of lesions >5 mm, but a high rate of false negative results in lesions <5 mm such as in carcinomatosis. PET/CT should be used carefully in early stage disease, with low risk of peritoneal infiltration, because of high rate of false positive results, to avoid unnecessary therapy procedures.  相似文献   

5.

Objective

To assess useful CT features for differentiating benign from premalignant and malignant macrocystic pancreatic lesions.

Methods

Seventy-four patients with pathologically proven macrocystic pancreatic lesions were enrolled: 17 benign cysts (macrocystic serous cystadenoma, n = 12; congenital cyst; n = 5) and 57 premalignant and malignant cysts (mucinous cystic neoplasm, n = 28; intraductal papillary mucinous neoplasm of branch duct type, n = 20; tumor with cystic change, n = 9). Size, location, shape (lobulated, round or oval, or complex cystic with tubular cyst), wall thickness (thin, ≤1 mm; thick, >1 mm), internal surface (smooth or irregular), and other findings were analyzed with multiphasic CT with thin-section (2.5-3 mm) images. CT features between two groups were compared using univariate and multivariate stepwise logistic regression analyses.

Results

On univariate analysis, the differences for the shape (p = 0.007), wall thickness (p = 0.011), and internal surface (p = 0.012) between benign and premalignant and malignant cysts were significant. A lobulated shape, a thin wall and a smooth internal surface were more frequent in benign cysts, whereas a round or oval shape or a complex cystic shape with tubular cyst, a thick wall and an irregular internal surface were more frequent in premalignant and malignant cysts. On multivariate analysis, the shape (p = 0.002) and wall thickness (p = 0.025) were significant CT features for differentiating benign from premalignant and malignant cysts.

Conclusion

Shape and wall thickness are the main CT features for differentiating benign from premalignant and malignant macrocystic pancreatic lesions.  相似文献   

6.

Objective(s)

Only few information exist about the diagnostic accuracy of PET/CT for restaging patients with metastatic recurrence of breast carcinoma. Therefore, our study hypothesis was to perform diagnostic contrast enhanced CT (ce-CT) and FDG-PET in a one-step investigation, to prove sensitivity of each modality and to determine whether diagnostic PET/CT adds information over PET or contrast enhanced CT alone for restaging of patients with suspected recurrence of breast cancer.

Methods

Fifty-two patients with suspected recurrence of breast cancer were included in our study. All of them were free of metastasis after the first line therapy. Indications for restaging were: Elevated tumor markers n = 32, clinical deterioration n = 16 and/or suspicious findings on other imaging studies n = 48. Integrated PET/CT was performed using contrast-enhanced diagnostic CT for attenuation correction.

Results

PET was correct in 44/52 patients (85%), ce-CT in 38/52 patients (73%) and PET/CT in 50/52 patients (96%). Sensitivity and specificity of lesion detection of PET, CT and PET/CT were 84%, 66% and 93%, and 100%, 92%, and 100%, respectively.

Discussion

PET/CT can improve staging and alter therapeutic options in patients suspected to have breast cancer recurrence and distant metastatic disease, primarily by demonstrating local or distant nodal involvement occult at other imaging studies. The added value of FDG-PET/CT over other diagnostic modalities is mainly expressed by the fact that a noninvasive whole-body evaluation is possible in a single examination.  相似文献   

7.

Purpose

To retrospectively evaluate previous imaging findings of breast cancers that occurred in women whose combined screening using both mammography and ultrasonography was negative.

Materials and methods

A search of the institutional database identified 65 patients with breast cancers who had comparable previous negative screening mammography and ultrasonography (BI-RADS category 1 or 2) within 2 years. We classified each case as true or false negative. The previous imaging findings and the final outcome were analyzed.

Results

Among 65 cases, 42 (65%) were true negatives, 23 (35%) were false negatives. The abnormalities of false negatives were underestimated in 16 (70%) and unrecognized in 7 (30%). The findings were calcifications (n = 8) or a mass (n = 6) on mammography, a mass (n = 5) or a non-mass (n = 3) on ultrasonography and a density on mammography correlated with non-mass on ultrasonography (n = 1). Ductal carcinoma in situ among false and true negatives accounted for 5 (22%) and 7 (17%), respectively. Symptomatic cancers among false and true negatives were 6 (26%) and 13 (31%), respectively.

Conclusion

Breast cancers that rarely occurred in combined screening negatives are often retrospectively seen as minimal abnormalities on previous imaging studies.  相似文献   

8.

Purpose

The clinical value of positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) for follow-up or suspected recurrence of renal cell carcinoma (RCC) has not been fully evaluated. The purpose of this study was to assess the diagnostic performance of FDG-PET for postoperative assessment in patients with RCC.

Methods

We reviewed 28 scans in 23 patients who had undergone FDG-PET scans after surgery for RCC. Diagnostic accuracy of visually interpreted PET was evaluated based on final diagnoses obtained histologically or by clinical follow-up at least 6 months. Also, additional information over CT, influence on treatment decisions, and the accuracy of FDG uptake as a predictor of survival were assessed.

Results

Recurrence of renal carcinoma was histologically (n = 15) or clinically (n = 6) confirmed in 21 of 28 cases. Overall, the sensitivity, specificity, and diagnostic accuracy using FDG-PET were 81%, 71%, and 79%, respectively. In papillary RCC, the sensitivity was 100%; however, that was 75% in clear cell RCC in patient-basis. PET correctly detected local recurrence and metastases in all cases in the peritoneum, bone, muscle and adrenal gland. Additional information was obtained from scans in 6 cases (21%), which influenced therapeutic management in 3 cases (11%). Cumulative survival rates over 5 years in the PET-positive vs. the PET-negative group were 46% vs. 83%, respectively (p = 0.17).

Conclusions

FDG-PET would be useful for postoperative surveillance in patients with RCC, although its impact on treatment decisions may be limited. Further investigations are necessary to conclude whether PET has a prognostic value.  相似文献   

9.

Purpose

To evaluate the performance of F-18 FDG PET/CT in the detection of bone metastasis in non-small cell lung cancer (NSCLC) patients.

Materials and methods

Three hundred and sixty-two consecutive NSCLC patients who underwent F-18 FDG PET/CT scanning were retrospectively analyzed. Each image of PET/CT, combined CT, and PET was performed at 10 separate areas and interpreted blindly and separately. The sensitivity, specificity and accuracy of F-18 FDG PET/CT, combined CT and F-18 FDG PET were calculated and the results were statistically analyzed.

Results

Bone metastasis was confirmed in 82 patients with 331 positive segments based on the image findings and clinical follow-up. On patient-based analysis, the sensitivity of F-18 FDG PET/CT (93.9%) was significantly higher than those of combined CT (74.4%) and F-18 FDG PET (84.1%), respectively (p < 0.05). The overall specificity and accuracy of combined CT, F-18 FDG PET, and F-18 FDG PET/CT were 90.7%, 93.2%, 98.9% and 87.0%, 91.2%, and 97.8%, respectively (compared with PET/CT, p < 0.05). On segment-based analysis, the sensitivity of the three modalities were 79.5%, 94.3%, and 98.8%, respectively (compared with PET/CT, p < 0.05). The overall specificity and accuracy of the three modalities were 87.9%, 89.2%, 98.6% and 84.5%, 91.2%, 98.7%, respectively (compared with PET/CT, p < 0.05).

Conclusion

F-18 FDG PET/CT is superior to F-18 FDG PET or combined CT in detecting bone metastasis of NSCLC patients because of the complementation of CT and PET. It is worth noting that the added value of F-18 FDG PET/CT may beneficially impact the clinical management of NSCLC.  相似文献   

10.

Purpose

To evaluate the incremental value of arterial and equilibrium phase compared to hepatic venous phase multidetector row CT (MDCT) in the preoperative staging of colorectal liver metastases (CLM) and to determine the influence of the reference standard.

Materials and methods

Fifty-three consecutive CLM patients underwent 16 detector row CT in hepatic arterial, venous, and equilibrium phase before surgery between March 2003 and January 2007. Detected lesions were characterized by three independent radiologists. The reference standard consisted of intraoperative palpation and ultrasound of the liver, and histopathological examination of the resected specimen. Additionally, data of follow-up CT was added. Statistical analysis was performed on a per-lesion basis.

Results

According to the reference standard 251 lesions were present, of which 203 (81%) were malignant (mean size: 29.4 ± 22.5 mm), and 41 (16%) were benign (mean size: 8.3 ± 7.7 mm). Sensitivity rates for CLM were comparable between triphasic and hepatic venous phase CT (P > 0.05). Sensitivity for the detection of CLM lowered from 60-77% to 52-68% when follow-up CT was added to the reference standard.

Conclusion

Arterial and equilibrium phase CT have no incremental value compared to hepatic venous phase MDCT in the detection of CLM. Sensitivity rates are, however, influenced by the type of reference standard used.  相似文献   

11.

Objective

Due to depressant effects of methanol on the central nervous system, brain computed tomography (CT) scan has been introduced as a diagnostic device in methanol intoxication. The authors aimed to present brain CT findings in patients with acute methanol intoxication and to determine signs associated with death.

Materials and methods

This cohort study involved 42 consecutive patients with acute methanol intoxication. Inclusion criteria were consisted of characteristic clinical presentation of methanol poisoning, and metabolic acidosis with increased anion and osmolar gaps. Brain CT scans without contrast medium were obtained. To determine the association between the CT findings and death, the chi-square test or the Fisher's exact test, odds ratio (OR) and its 95% confidence interval (95% CI) were calculated.

Results

Twenty-eight patients (66.6%) had a total of 55 abnormal findings on brain CT, in which bilateral putaminal hypodense lesions was the most common manifestation (27 cases, 96.4%). Putaminal hemorrhage with varying degrees was observed in 7 patients (25%). Six patients (21.4%) had low attenuation lesions in the subcortical white matter of the insula. A significant association was observed between putaminal hemorrhage (OR = 8, 95% CI = 1.187-53.93, P = 0.018) and subcortical necrosis of the insula (OR = 11, 95% CI = 1.504-80.426, P = 0.007) with death.

Conclusion

In addition to clinical and laboratory findings, presence of putaminal hemorrhage and insular subcortex white matter necrosis are associated with a poor clinical outcome in patients with methanol poisoning.  相似文献   

12.

Purpose

To evaluate the value of T2w endorectal MRI (eMRI) for correct detection of tumor foci within the prostate regarding tumor size.

Materials and Methods

70 patients with histologically proven prostate cancer were examined with T2w eMRI before radical prostatectomy at a 1.5 T scanner. For evaluation of eMRI, two radiologists evaluated each tumor focus within the gland. After radical prostatectomy, the prostates were prepared as whole-mount sections, according to transversal T2w eMRI. For each slice, tumor surroundings were marked and compared with eMRI. Based on whole-mount section, 315 slices were evaluated and 533 tumor lesions were documented.

Results

Based on the T2w eMRI, 213 tumor lesions were described. In 137/213, histology could prove these lesions. EMRI was able to visualize 0/56 lesions with a maximum size of <0.3 cm (detection rate 0%), between 0.3 and 0.5 cm 4/116 (3%), between 1 and 0.5 cm 22/169 (13%), between 2 and 1 cm 61/136 (45%) and for >2 cm 50/56 (89%). False positive eMRI findings were: <0.3 cm n = 0, 0.5-0.3 cm n = 12, 0.5-1 cm n = 34, 1-2 cm n = 28 and >2 cm n = 2.

Conclusion

T2w eMRI cannot exclude prostate cancer with lesions smaller 10 mm and 0.4 cm3 respectively. The detection rate for lesions more than 20 mm (1.6 cm3) is to be considered as high.  相似文献   

13.

Background and objective

The management of community-acquired pneumonia (CAP) depends, in part, on the identification of the causative agents. The objective of this study was to determine the potential of thin-section computed tomography (CT) in differentiating bacterial and non-bacterial pneumonia.

Patients and methods

Thin-section CT studies were prospectively examined in hospitalized CAP patients within 2 days of admission, followed by retrospective assessment by two pulmonary radiologists. Thin-section CT findings on the pneumonias caused by each pathogen were examined, and two types of pneumonias were compared. Using multivariate logistic regression analyses, receiver operating characteristic (ROC) curves were produced.

Results

Among 183 CAP episodes (181 patients, 125 men and 56 women, mean age ± S.D.: 61.1 ± 19.7) examined by thin-section CT, the etiologies of 125 were confirmed (94 bacterial pneumonia and 31 non-bacterial pneumonia). Centrilobular nodules were specific for non-bacterial pneumonia and airspace nodules were specific for bacterial pneumonia (specificities of 89% and 94%, respectively) when located in the outer lung areas. When centrilobular nodules were the principal finding, they were specific but lacked sensitivity for non-bacterial pneumonia (specificity 98% and sensitivity 23%). To distinguish the two types of pneumonias, centrilobular nodules, airspace nodules and lobular shadows were found to be important by multivariate analyses. ROC curve analysis discriminated bacterial pneumonia from non-bacterial pneumonia among patients without underlying lung diseases, yielding an optimal point with sensitivity and specificity of 86% and 79%, respectively, but was less effective when all patients were analyzed together (70% and 84%, respectively).

Conclusion

Thin-section CT examination was applied for the differentiation of bacterial and non-bacterial pneumonias. Though showing some potential, this examination at the present time would not be applicable for patients with underlying lung diseases, severe conditions of pneumonia, or immunocompromised conditions.  相似文献   

14.

Purpose

To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.

Materials and methods

Ten knees were scanned with a 1.5 T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5 mm, 3.0 mm and 5.0 mm slices using the Argus® software application. Accuracy and time effectiveness served as control parameters.

Results

Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6 ± 127.7 s and 379.1 ± 117.6 s to 214.9 ± 109.9 s and 213.9 ± 102.2 s to 122.1 ± 60.1 s and 126.8 ± 56.2 s and for the medial tibial plateau from 465.0 ± 147.7 s and 461.8 ± 142.7 s to 214.0 ± 67.9 s and 208.9 ± 66.2 s to 132.6 ± 41.5 s and 130.6 ± 42.0 s measuring 1.5 mm, 3 mm and 5 mm slices, respectively. No statistically significant difference between cartilage volume measurements was observed (p > 0.05) while very good inter-reader correlation was evaluated.

Conclusion

CVM using 1.5 mm slices provides no higher accuracy than cartilage volume measurement in 5 mm slices while an overall time saving up to 70% is possible.  相似文献   

15.

Purpose

To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates.

Materials and methods

Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV1) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome.

Results

Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (−0.60 ≤ r ≤ −0.42, p < 0.05).

Conclusion

Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.  相似文献   

16.

Objectives

To determine the computed tomography (CT) features of adenomyosis in patients with known adenomyosis as established with magnetic resonance (MR) imaging.

Methods

A computerized search identified 16 women with pelvic MR diagnosis of adenomyosis who also had enhanced pelvic CT. Original CT reports were reviewed for potential prospective diagnosis of adenomyosis. CT images were reviewed for enhancement phase, inner and outer myometrium attenuation, uterine enlargement (width>6 cm), inner myometrial thickening (≥12 mm), and myometrial cysts.

Results

Adenomyosis was detectable on CT in 8 of 16 patients. For these 8 patients, inner and outer myometrium distinction was excellent in 7 (88%) and limited in 1 (12%), and mean inner myometrial thickness was 25 mm (range 14-47 mm). CT enhancement phase was parenchymal in 7 (88%), uterus was enlarged in 8 (100%), and 7 (88%) had myometrial cysts. Adenomyosis was focal in 5 (63%), diffuse in 2 (25%), and both in 1 (12%). None of the original CT reports included adenomyosis as a diagnosis.

Conclusions

CT can suggest a diagnosis of adenomyosis based on uterine enlargement, thickened inner myometrium, and/or myometrial cysts.  相似文献   

17.

Aim

Conventional MRI and the recently developed diffusion weighted imaging (DWI) technique both are being used for the detection of pelvic lymph node metastasis in gynaecologic cancers. Little is known about the reproducibility of DWI. This study assesses the reproducibility of pelvic lymph node detection by conventional MRI and DWI.

Materials and methods

17 patients with gynaecological malignancies eligible for curative surgery were selected as population of interest. They had undergone preoperative conventional MRI and DWI on a 3.0 T MR scanner. All images were evaluated by two experienced radiologists. Inter- and intra-observer agreements were assessed, and whether lymph node size and region were related to reproducibility. Differences were tested by Chi-square statistics.

Results

The reproducibility ranged between 42% and 65% for the two observers and for the two imaging tests, conventional MRI and DWI. Higher percentages of agreement were found for larger lymph nodes, i.e. for long as well as short axis diameter exceeding 5 mm. Also, agreement was better for lymph nodes in the external iliac region and the obturator region compared to detection of lymph nodes in the common iliac area. Results for the newer technique, DWI, were comparable to the results of the more conventional MRI sequences.

Conclusion

Reproducibility of MRI and DWI in the detection of pelvic lymph nodes in patients with a gynaecological malignancy was similar. For lymph nodes exceeding 5 mm in both long and short axis diameter the agreement was considerably better than for smaller nodes.  相似文献   

18.

Background

Patients affected by scleroderma may complain of sensory disturbances especially in the hands.

Purpose

To study the imaging features of upper limb nerves in patients affected by scleroderma (SSc).

Materials and method

Twenty-five patients affected only by SSc were prospectively evaluated with high-resolution US and magnetic resonance (MRI) or computer tomography (CT) when necessary (2 patients). Median and ulnar nerves were evaluated bilaterally. Nerve conduction studies were performed in the symptomatic patients (n = 10). Results of imaging studies were correlated with disease duration, autoimmunity and immunosuppression. Nerves of SSc patients were compared with a control group of 90 patients matched for age and body mass index.

Results

The prevalence of sensory disturbances revealed by clinical examination was 40%. In symptomatic SSc patients (n = 10) US evaluation revealed nerve abnormalities in 70% of cases (n = 7/10). n = 2 had a carpal tunnel syndrome. n = 5 had cubital tunnel syndrome. In two of them CT and MR were necessary to identify the compressed nerve at the level of the elbow due to the presence of calcifications. There was no association between the presence of an entrapment neuropathy and disease duration, autoantibodies and immunosuppression.

Conclusion

Ultrasound, CT and MR may detect nerve abnormalities in 70% of SSc patients complaining of neurologic disturbances in the hands. The results of imaging studies support the hypothesis of a vascular dependent neuropathy in SSc.  相似文献   

19.

Purpose

To determine the frequency and significance of pulmonary nodules detected on thin-section CT in patients with extrapulmonary malignant neoplasms.

Materials and methods

The institutional review board approved this study. This study retrospectively evaluated 308 patients with extrapulmonary carcinomas or sarcomas and had undergone thin-section chest CT (2 mm slice thickness) for staging. Three radiologists identified non-calcified nodules and evaluated the size, the growth and the distance from the nearest pleural surface. The characteristics of the nodules were defined based on the results of either a diagnostic biopsy or nodule growth.

Results

One or more non-calcified pulmonary nodules were detected in 75% of the patients (233/308). One hundred and thirty-seven of these patients had nodules that met the criteria of either benign or malignant nodules. Nodules smaller than 10 mm were more likely to be benign, whereas those 10 mm or greater were more likely to be malignant (22/26, 85%; P < .0001). Most nodules less than 10 mm from the pleura were benign (91%), whereas approximately half of the nodules 10 mm or more away from the pleura were malignant (20/43, 47%; P < .0001). Patients with melanoma, sarcoma, or testicular carcinoma were more likely to have malignant nodules. A multivariable analysis demonstrated the nodule size (P < .0001) and distance from the pleura were predictive of malignancy.

Conclusion

The nodule detection rate on thin-section CT in patients with extrapulmonary malignancy is high. Most of the nodules smaller than 10 mm or less than 10 mm from the pleura are benign.  相似文献   

20.

Purpose

To evaluate whether dual-time point scanning with integrated fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography and computed tomography (PET/CT) is useful for evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT.

Materials and methods

PET/CT data and pathological findings of 560 nodal stations in 129 patients with pathologically proven non-small cell lung cancer diagnosed as operable by contrast-enhanced CT were reviewed retrospectively. Standardized uptake values (SUVs) on early scans (SUVe) 1 h, and on delayed scans (SUVd) 2 h after FDG injection of each nodal station were measured. Retention index (RI) (%) was calculated by subtracting SUVe from SUVd and dividing by SUVe. Logistic regression analysis was performed with seven kinds of models, consisting of (1) SUVe, (2) SUVd, (3) RI, (4) SUVe and SUVd, (5) SUVe and RI, (6) SUVd and RI, and (7) SUVe, SUVd and RI. The seven derived models were compared by receiver-operating characteristic (ROC) analysis. k-Fold cross-validation was performed with k values of 5 and 10. p < 0.05 was considered statistically significant.

Results

Model (1) including the term of SUVe showed the largest area under the ROC curve among the seven models. The cut-off probability of metastasis of 3.5% with SUVe of 2.5 revealed a sensitivity of 78% and a specificity of 81% on ROC analysis, and approximately 60% and 80% on k-fold cross-validation.

Conclusion

Single scanning of PET/CT is sufficiently useful for evaluating mediastinal and hilar nodes for metastasis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号