首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Transcatheter aortic valve replacement is standard of care for patients with severe aortic stenosis at high risk for surgical aortic valve replacement. Although not intended for treatment of primary aortic insufficiency, several transcatheter aortic valve prostheses have been used to treat patients with severe aortic insufficiency (AI), including patients with left ventricular assist devices (LVAD), in whom significant AI is not uncommon. Similarly, transcatheter valve replacements have been used for valve‐in‐valve treatment, in the pulmonary, aortic, and mitral positions, either via a retrograde femoral approach or antegrade transseptal approach (mitral valve‐in‐valve). In this case report, we report an LVAD patient with severe aortic insufficiency and severe bioprosthetic mitral prosthetic stenosis, in whom we successfully performed transfemoral aortic valve replacement and transfemoral mitral valve‐in‐valve replacement via a transseptal approach. © 2017 Wiley Periodicals, Inc.  相似文献   

2.
We present the case of an 85‐year‐old woman diagnosed with severe aortic stenosis, porcelain aorta, and a small aortic annulus (17.3 mm), who underwent successful transfemoral transcatheter aortic valve implantation (TAVI) with a 20‐mm Edwards SAPIEN XT valve using the NovaFlex+ delivery system. At 1‐month follow‐up the patient was in NYHA functional class I, and Doppler echocardiography showed a mean residual gradient of 15 mm Hg and trivial paravalvular aortic regurgitation. This case, which shows for the first time the feasibility of TAVI with a 20‐mm valve, opens a new avenue for the challenging treatment of patients with aortic stenosis and a small aortic annulus. © 2011 Wiley Periodicals, Inc.  相似文献   

3.
Background: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. Case report: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79‐year‐old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. Conclusion: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe. © 2008 Wiley‐Liss, Inc.  相似文献   

4.
Aorto‐atrial fistulas are rare, but important complications resulting from aortic valve infective endocarditis, aortic valve surgery, or aortic dissection. We hereby report a case of a 20‐year male, referred to us with infective endocarditis of the native aortic valve with severe aortic regurgitation and symptoms of heart failure. Detailed evaluation with two‐dimensional and three‐dimensional transthoracic echocardiography revealed aorto‐left atrial fistula secondary to the involvement of the mitral–aortic intervalvular fibrosa (MAIVF) region. The patient underwent successful removal of the vegetations, closure of the defect along with aortic valve replacement, and mitral valve repair.  相似文献   

5.
Transcatheter aortic valve replacement (TAVR) is well‐established for the treatment of bioprosthetic aortic valve stenosis (AS) in high surgical risk patients. Coronary artery obstruction from displacement of the bioprosthetic valve leaflets during valve‐in‐valve (VIV) TAVR is a rare, but potentially fatal, complication. Recently, the bioprosthetic aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) procedure was developed as a method for disrupting bioprosthetic leaflets in patients undergoing VIV TAVR at high risk for coronary obstruction. This case describes a successful VIV TAVR utilizing a simplified concept of the BASILICA technique in a patient where the full procedure could not be completed.  相似文献   

6.
Transfemoral aortic valve implantation (TAVI) for the treatment of pure native aortic insufficiency is not routine clinical practice. Absent cusp calcification, missing landmarks in combination with no perfect valve control during release with first‐generation TAVI devices resulted in a high rate for need of a second valve or relevant residual aortic insufficiency. We report the first case with a native pure aortic valve insufficiency at high surgical risk successfully treated by implantation of the repositionable and completely retrievable Lotus valve, resulting in a well‐controlled and safe procedure with no residual aortic insufficiency. © 2015 Wiley Periodicals, Inc.  相似文献   

7.
Transcatheter aortic valve implantation (TAVI) is commonly associated with some degree of aortic regurgitation (AR) secondary to the presence of paravalvular leaks. We present the case of an 86‐year‐old woman diagnosed with severe aortic stenosis who underwent TAVI with a 23‐mm Edwards‐SAPIEN valve. The procedure complicated with a severe paravalvular leak following TAVI that was unresponsive to balloon postdilation. This complication was successfully managed with the implantation of a second valve of the same diameter within the first one (“valve‐in‐valve”) resulting in trivial residual AR and the absence of significant transvalvular gradient at the end of the procedure. © 2009 Wiley‐Liss, Inc.  相似文献   

8.
We describe the case of a 62‐year‐old female presenting with new onset progressive dyspnea on exertion and a new diagnosis of aortic stenosis. Transesophageal echocardiography showed fusion of the aortic valve leaflets suspicious for bicuspid aortic valve with dilated ascending aorta. Surgical replacement of the valve revealed a unicuspid aortic valve with one true commissure at the level of the left and noncoronary cusps. The case is supported by clinical, echocardiographic and angiographic imaging and discussion of current imaging modalities used in diagnosis of aortic valve pathology.  相似文献   

9.
We report a challenging case of transcatheter aortic valve‐in‐valve implantation in an elderly patient with failed surgical bioprosthesis. The transthoracic echocardiogram demonstrated a severe stenosis with a peak gradient of 142 mm Hg. The patient was a high‐risk candidate for reoperative valve replacement; therefore, transfemoral implantation of a CoreValve (Medtronic Inc, Minneapolis, MN) was decided. During the procedure, we were unable to introduce the delivery catheter system across the bioprosthesis due to its poor alignment with the aortic annulus and the severity of the stenosis. With strategies involving transseptal puncture and externalization of a guidewire in an antegrade manner, the CoreValve was successfully positioned and deployed. This case illustrated the utility of transseptal strategies in challenging retrograde transcatheter aortic valve‐in‐valve implantation. © 2013 Wiley Periodicals, Inc.  相似文献   

10.
Prosthetic valve infective endocarditis (IE) is one of the most serious postimplantation complications. Prosthetic aortic valve IE constitutes 1%–6% of all prosthetic valve IE cases. We present a dramatic echocardiographic case of prosthetic aortic valve IE leading to near‐complete valve dehiscence. Echocardiographic evidence of prosthetic aortic valve rocking motion is indicative of significant dehiscence. Aside from IE, other causes and risk factors for prosthetic aortic valve dehiscence include inflammatory and autoimmune vasculitides, concomitant ascending aorta aneurysm, and aortic root calcification.  相似文献   

11.
Transcatheter aortic value implantation has gained acceptance as a treatment for elderly patients considered high risk for surgical aortic valve replacement. There are still, however, many unresolved clinical and technical issues. The occurrence of transcatheter aortic valve‐in‐valve implantation has been reported anecdotally. Aside from a single case report, there is little literature on this topic. This study was conducted to evaluate the procedural, imaging, and clinical outcomes of patients who underwent transcatheter valve‐in‐valve implantation with two self‐expanding aortic valve bioprostheses during the same procedure. We discuss also the potential valve of on‐line quantitative angiography for assessing the depth of valve implantation and the need to implant a second valve. © 2009 Wiley‐Liss, Inc.  相似文献   

12.
Transcatheter aortic valve implantation (TAVI) is a viable treatment option for high‐ and prohibitive‐risk patients with severe, calcified pure or predominant aortic valve stenosis, but not for pure aortic valve regurgitation. In fact, the use of TAVI for this indication is even considered unlikely due to the lack of calcium which appears essential for anchoring the stent‐valve and prevents dislocation. We report a case of a patient with severe, symptomatic pure aortic regurgitation, and a history of two previous open‐heart surgeries who was successfully treated by compassionate use implantation of an oversized Medtronic CoreValve prosthesis as an ultima ratio treatment option. © 2012 Wiley Periodicals, Inc.  相似文献   

13.
In the last years, the use of sutureless devices in frail patients with severe aortic stenosis has increased thanks to their “easier and faster” technique of implantation in comparison to conventional surgery. Results from metanalysis show comparable outcomes in comparison to transcatheter aortic valve replacement (TAVR) in terms of mortality, stroke incidence, and rate of pace‐maker implantation. The incidence of para‐valvular leak (PVL) is even lower for sutureless devices than for TAVR. The few cases described are generally due to incomplete decalcification or incorrect valve sizing and consequent stent distortion. To our knowledge this is the first case describing PVL with massive aortic regurgitation due to early partial embolization of a Perceval valve and its successfully treatment with valve‐in‐valve by using a self‐expanding TAVR device.  相似文献   

14.
Transcatheter aortic valve implantation is an alternative to conventional aortic valve replacement for patients at high surgical risk, with favorable procedural outcomes. Aortic regurgitation remains an off‐label indication. Recent case reports describe the successful use of a second CoreValve inside a malpositioned first CoreValve. In the current case, we report for the first time a valve‐in‐valve procedure for the treatment of a severely insufficient CoreValve prosthesis using the Edwards‐Sapien prosthesis. © 2009 Wiley‐Liss, Inc.  相似文献   

15.
Unicuspid aortic valve (UAV) is a rare congenital anomaly of aorta associated with a faster progress of valvular dysfunction, aortic dilatation and with necessity for more frequent controls and precise evaluation Asymptomatic 35 year old man had abnormal systolic diastolic murmur on aortic valve during routine examination. Initial diagnostic with transthoracic echocardiography (TTE) supposed bicuspid aortic valve, while three‐dimensional transesophageal echocardiography (3D TEE) and multidetector computed tomography defined unicuspid, unicomissural aortic valve with moderate aortic stenosis and regurgitation. This case report confirmed that 3D TEE gives us opportunity for early, improved and precise diagnosis of UAV.  相似文献   

16.
We report a case of emergency transcatheter aortic valve replacement (TAVR) in a 65‐year‐old patient presenting with decompensated severe aortic stenosis. Transesophageal echocardiography (TEE) was used effectively to obtain measurements of the aortic annulus and for intra‐procedural guidance. At baseline, we detected a left atrial appendage thrombus and a localized aortic root dissection after balloon valvuloplasty. The case highlights the important role that TEE may play during TAVR procedures.  相似文献   

17.
Transcatheter aortic valve implantation (TAVI) has been developed as an alternative to conventional aortic valve replacement for the treatment of symptomatic severe aortic stenosis in high‐risk patients. Nevertheless, TAVI has been associated with serious complications such as stroke, vascular injury, renal failure, and arrhythmia. Herein we describe a case of distortion of the Edward‐Sapien prosthesis (Edwards Lifesciences, USA), which was mounted on a balloon‐expandable stent, after chest compression for cardiac resuscitation in a patient who underwent TAVI for severe aortic stenosis. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
Transcatheter aortic valve replacement is an approved treatment for select patients with severe aortic stenosis. A rare complication of self‐expanding transcatheter heart valves (THVs) is infolding of the valve stent frame, which results in a malopposed segment, perivalvular aortic insufficiency, and possibly leaflet dysfunction. We report here a successful case of balloon valvuloplasty treatment for severe infolding of a self‐expandable THV in the aortic position, restoring stent frame geometry and leaflet function. © 2015 Wiley Periodicals, Inc.  相似文献   

19.
Transcatheter aortic valve implantation (TAVI) is a highly effective procedure for selected patients who are at high risk for aortic valve replacement; however, the incidence of severe complications is still relevant. Coronary occlusion during TAVI is a life‐threatening complication that requires immediate diagnosis and treatment. We report the case of an 87‐years‐old woman affected by severe aortic stenosis, symptomatic for refractory heart failure, who underwent urgent balloon aortic valvuloplasty and subsequent elective transapical aortic valve implantation. Valve deployment was complicated by cardiac arrest and hemodynamic collapse, and left main coronary artery occlusion was recognized and successfully recovered by balloon angioplasty and stent implantation. Patient is alive and well 6 months after procedure. © 2011 Wiley‐Liss, Inc.  相似文献   

20.
The mitral valve aneurysm is a rare complication of infective endocarditis involving mitral or aortic valve. The perforation of the mitral valve aneurysm can lead to significant mitral regurgitation (MR) or thromboembolism, which can cause sudden hemodynamic deterioration. We describe here a case of healed infective endocarditis of the aortic valve with ruptured mitral valve aneurysm that led to severe MR. The aneurysm of the anterior mitral leaflet was diagnosed by two‐dimensional transthoracic echocardiography. In this case, three‐dimensional transthoracic echocardiography demonstrated the detailed morphology of mitral valve aneurysm which resulted in successful surgical repair of the aneurysm.  相似文献   