首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Serum antibody responses to influenza A virus infection were examined in 388 normal subjects during a trial of chemoprophylaxis in an outbreak of influenza A in 1980-1981 in which both A/H1N1 and A/H3N2 viruses circulated. Paired serum specimens obtained over a 6-week period were tested for antibodies to both A/H1N1 and A/H3N2 viruses by conventional hemagglutination inhibition, complement fixation, and an enzyme-linked immunosorbent assay (ELISA). Antibody responses detected by ELISA were determined by calculation of the area generated between titration curves of paired sera (area method), as well as by a conventional endpoint dilution method (endpoint method). Forty-two significant antibody rises were detected; 42 by ELISA (area method), 33 by ELISA (endpoint method), 32 by hemagglutination inhibition, and 13 by complement fixation. ELISA (area method) detected rises more frequently than either ELISA (endpoint method) (P less than 0.01), hemagglutination inhibition (P less than 0.005), or complement fixation (P less than 0.001). Another sensitive assay, the microneutralization test, detected significantly fewer rises (33, P less than 0.025) than the ELISA (area method). In the 42 subjects with ELISA (area method) rises, corroborating evidence of influenza A infection by other techniques (virus isolation, microneutralization, hemagglutination inhibition, or complement fixation tests) were available for 39 (93%). ELISA (area method) rises were subtype specific in all serum pairs in which other documentation of subtype-specific infection was available (38 of 38). Thus, ELISA (area method) was the single most sensitive assay for detection of serum antibody rises in this setting and possessed a high degree of subtype specificity.  相似文献   

2.
Sera from patients with St. Louis encephalitis were tested with an immunoglobulin M (IgM) antibody capture enzyme immunoassay (MAC ELISA). The assay used five reagents: antihuman IgM, test serum, sucrose-acetone-extracted mouse brain antigen, broadly cross-reactive flavivirus monoclonal antibody conjugated to alkaline phosphatase, and substrate (p-nitrophenyl phosphate). MAC ELISA endpoint titers correlated (r = 0.893) with the absorbance value of a 1:100 dilution of patient serum. Significant (fourfold or greater) changes in the endpoint titers between paired sera corresponded to a critical ratio (ratio of absorbance values at the 1:100 dilution) of greater than or equal to 1.3. IgM antibodies were detected in 71% of patients bled at 0 to 3 days after the onset of illness, in 99% bled at 4 to 21 days, and in 91% bled at 22 to 67 days. Thereafter, the IgM seropositivity rate declined; however, 29% of sera were still positive at 115 to 251 days after the onset of illness. MAC ELISA titers were significantly correlated with hemagglutination inhibition (r = 0.258) and neutralization (r = 0.711) titers. Because IgM antibodies appeared early and waned rapidly, a diagnosis was made on the basis of a decrease in titer more often by MAC ELISA than by hemagglutination inhibition, complement fixation, or neutralization tests. IgM antibodies generally showed a high degree of specificity; heterologous cross-reactions were, however, present in 4 of 14 sera examined. The MAC ELISA is useful for the rapid, early diagnosis of St. Louis encephalitis.  相似文献   

3.
Enzyme-linked immunosorbent assay (ELISA) for toxoplasmosis was evaluated in serum samples presenting defined toxoplasmosis serological patterns, as determined by results in immunoglobulin (Ig)G and IgM immunofluorescence (IgG-IF, IgM-IF), hemagglutination, and complement fixation tests. ELISA was carried out with alkaline phosphatase-labeled anti-IgG and anti-IgM antibodies. Serum titer was expressed as the serum dilution end point determined by mere observation of color development in the test. A straight agreement was found between IgG-ELISA and IgG-IF titers, both in group A sera of ancient infections (patterns II and III) and group B sera of recent infections (pattern I). A similar agreement was found between IgG-ELISA and hemagglutination titers in group A sera, for which coincident IgG-IF and hemagglutination titers are also frequent. However, in group B sera, in spite of the same toxoplasma extract being used to sensitize both plastic surfaces and erythrocytes, IgG-ELISA titers were much higher than hemagglutination titers, in a way similar to that observed for IgG-IF titers. IgM-ELISA was positive in every group B serum, with higher titers than corresponding IgM-IF titers. Occasional low-titered positive IgM-ELISA results were seen for group A sera, sometimes due to IgM-antiglobulin antibodies. An easy test to perform, ELISA seems to be an adequate substitute for toxoplasmosis IF tests for routine purposes.  相似文献   

4.
A micro enzyme-linked immunosorbent assay for insulin antibodies in serum   总被引:2,自引:0,他引:2  
A solid-phase micro enzyme-linked immunosorbent assay for the measurement of insulin antibodies in serum is described and its performance compared with that of an established radiobinding assay. Interassay precision in the ELISA was 10% or less at widely spaced points on the dilution curves for human, porcine and bovine insulins. Specificity was demonstrated by substituting purified human gamma-globulin for the test serum and glucagon for the insulin. The influence on ELISA of endogenous insulin in the test serum was examined by measuring antibody binding before and after extraction of the insulin. The correlation between results from extracted and unextracted sera was 0.96 and the fit ideal: y = 1.00x + 0.38%. The correlation between the results of measuring insulin antibody in 256 diabetic sera by the 2 assays was r = 0.74, P less than 0.001 (human insulin) and r = 0.71, P less than 0.001 (porcine insulin). ELISA is cheap and simple to perform. We believe it may prove to be a practical alternative to radioassay in both the routine detection and investigative research of insulin antibodies.  相似文献   

5.
An enzyme-linked immunosorbent assay (ELISA) has been developed for titration of IgG and IgA antibodies to respiratory syncytial (RS) virus in low dilutions of human serum, colostrum, and nasopharyngeal secretions. Previously the sensitivity of RS virus ELISA on such specimens has been limited by nonspecific absorption of antibody, particularly IgA, to crude antigen preparations. For IgG antibody estimation in infant sera, this unwanted binding was reduced to workable levels by increasing the serum, salt, and detergent concentration of the diluent. Residual nonspecific binding of IgA in colostra appeared mainly due to antigen lipids or to lipoproteins. This was markedly reduced by partitioning Triton X-100-treated infected cell lysate antigens in Arklone. Using the modified ELISA technique for anti-RS virus IgA, good correlations were found with unfixed cell membrane immunofluorescence (MIF) for colostra (r = 0.81, P less than 0.001) and nasal secretions from adult volunteers. In several samples nonspecific absorption of antibody precluded MIF assay, but did not affect the ELISA. Although there was an overall correlation between ELISA for anti-RS IgG antibody in sera, the complement fixation test (r = 0.75, P less than 0.001), and MIF test (r = 0.82, P less than 0.001), the sensitivity of ELISA for antibody responses in convalescent sera of infants from 3 months to 2 years was poor. Conversely, the sensitivity of ELISA for antibody in the sera of older children and for transplacentally acquired antibody in very young infants was higher than that for the other two tests. ELISA was thus less reliable than either CF or MIF for detecting antibody rises in paired infant sera, particularly where maternally acquired antibody remained in the acute serum. The reasons for this apparent disparity are discussed.  相似文献   

6.
A sensitive and reproducible enzyme-linked immunosorbent assay (ELISA) is described for the detection of immunoglobulin M and antibodies with specifity for human cytomegalovirus (CMV) early (CMV-EA) and late (CMV-LA) antigens. The emphasis is on the production of high-quality CMV antigens, CMV-EA and CMV-LA separately, and conditions for their application in the ELISA. The induction of CMV-EA and -LA in infected cell extracts was studied in detail by using human sera with defined antibody specificity for CMV-EA and CMV-LA. This resulted in the development of a simple whole cell extraction procedure that provided a high yield of CMV antigens with reproducible antigen quality. The antigens were specific for the detection of anti-CMV antibodies. The influence of autoantibodies on the determination of CMV-specific antibodies was investigated. Parallel analysis of 322 human sera by indirect immunofluorescence and ELISA showed a high correlation between both assays (r = 0.9674 for CMV-EA and 0.9362 for CMV-LA). Antibody titers determined by ELISA were equal to (for CMV-EA) or slightly higher (for CMV-LA) that those determined by immunofluorescence but significantly higher (20- to 5,120-fold) than those determined by complement fixation. From 191 sera positive by ELISA (titer greater than or equal to 40) 4 (2.1%) were negative by immunofluorescence (titer less than 40), and from 61 ELISA-positive sera 12 (19.6%) were negative (titer less than 8) when tested by complement fixation. Consequently, ELISA for CMV may prove to be more reliable for the selection of CMV-seronegative blood donors than these other methods. The use of high-quality antigens allows more economic handling of large-scale serum determinations. Possibilities for further automation are discussed.  相似文献   

7.
Enzyme-linked immunosorbent assay (ELISA) was used for detection of antibodies against Mycoplasma pneumoniae. The results of ELISA were compared with those of other serological methods, such as complement fixation, metabolic inhibition, mycoplasmacidal test, and radioimmunoprecipitation. ELISA and mycoplasmacidal test showed greater sensitivity than did complement fixation and metabolic inhibition. Radioimmunoprecipitation showed serum titers 2- to 16-fold higher. Specificity of ELISA was determined by testing other human mycoplasmas. A simplified method based on the determination of ELISA antibody end-point titer by a single serum dilution is proposed.  相似文献   

8.
An enzyme-linked immunosorbent assay(ELISA) was developed for the detection of toxoplasma antibodies using a single serum dilution (1:800) in conjunction with a standard curve Antigen was prepared from Toxoplasma gondii cultivated in human cell cultures. A nearly linear relationship was found between the logarithms of the absorbance values of 120 human sera at a dilution of 1/800 and the titres as determined by an end point dilution ELISA. The reproducibility of the single dilution ELISA was excellent; the coefficients of variation for within-day and day-to-day tests were less than 15%. A close correlation was found between the results obtained with ELISA, indirect immunofluorescence (IF), and complement fixation (CF). The titres in ELISA were 20 to 40 times higher than in IF and 200 to 1000 times higher than in CF.  相似文献   

9.
Human anti-interleukin 1 alpha antibodies   总被引:4,自引:0,他引:4  
Autoantibodies to the cytokine interleukin (IL)-1 alpha are frequently found in sera of apparently healthy humans. We have developed a sensitive radioimmunoassay (RIA) and an indirect enzyme-linked immunosorbent assay (ELISA) for the detection of human serum antibodies to IL-1 alpha at concentrations below 10 pmol/l. The RIA is based on coprecipitation of 125I-labelled human recombinant IL-1 alpha (rIL-1 alpha) by rabbit antibodies to human immunoglobulins. The ELISA is based on recovery of added rIL-1 alpha to serum samples and takes advantage of the fact that free human autoantibodies to IL-1 alpha in a dose dependent manner reduce recovery of added rIL-1 alpha. The assays correlate exceedingly well (r = 0.99, P less than 0.001). Their inter- and intraassay coefficients of variation were less than 30% and less than 5% (RIA) and less than 20% and less than 10% (ELISA). Both assays were used to measure the presence of anti-IL-1 alpha antibodies in sera of patients with various autoimmune diseases. Autoantibodies to IL-1 alpha were detectable in up to 75% of these sera, but the frequencies and titers varied considerably between individuals with different diseases.  相似文献   

10.
An antibody capture enzyme-linked immunosorbent assay (ELISA) that uses horseradish-peroxidase-labeled antigen for the detection of immunoglobulin G (IgG) antibodies to cytomegalovirus (CMV) is described. A microtiter plate was coated with anti-human IgG and consecutively incubated with serum specimens, enzyme-labeled CMV antigen made from CMV-infected cell nuclei, and substrate. The CMV IgG antibody content was determined spectrophotometrically and expressed as absorbance. Furthermore, to reveal any nonspecific reactions, all sera were tested against an enzyme-labeled control antigen made from uninfected cell nuclei. The problem with nonspecific reactions was small and was circumvented by the addition of unlabeled control antigen to the conjugates. For epidemiological studies the test was not as sensitive as other serological tests. On the other hand, the IgG antibody capture ELISA was highly sensitive for detecting the serological antibody response in patients with primary and recurrent CMV infections. Thus, one positive serum remained positive at a serum dilution of 1:10(7). The specificity of the test was shown by a blocking experiment and by testing 126 complement fixation-positive sera, of which 97% were positive. There was a rather good correlation between the complement fixation test and the IgG antibody capture ELISA (rs = 0.79, P less than 0.001). The test is especially useful when tests for CMV antibodies of the IgM, IgA, and IgE classes are run by similar antibody capture ELISAs, since the same procedure and conjugate are used.  相似文献   

11.
An enzyme-linked immunosorbent assay (ELISA) has been developed for the titration of rickettsial antibodies in human and animal sera. Two preparations of soluble typhus-group antigens were obtained from Rickettsia typhi and Rickettsia prowazekii by ether extraction: a standard antigen from infected yolk sacs (YS antigen) and one free of yolk sac contaminants from Renografin-purified rickettsiae (PR antigen). Rabbit, mouse, and guinea pig sera were obtained by immunization with viable purified R. typhi or R. prowazekii. Human sera were obtained from individuals who had recovered from laboratory infections with either typhus rickettsia months or years previously. Goat-derived anti-immunoglobulins were conjugated to alkaline phosphatase with glutaraldehyde. Although the PR and YS antigens gave equivalent antibody titers in the complement fixation test, the PR antigen was clearly superior in the ELISA. With this antigen, the titration curves of all antisera were linear over a wider range of serum concentrations and the titers were higher than with the YS antigen. With YS and PR antigens, ELISA titers were higher than those obtained by complement fixation by one and two orders of magnitude, respectively. In human sera, immunoglobulin G and immunoglobulin M antibodies were demonstrated by their respective anti-immunoglobulins and by differential susceptibility to ethanethiol. ELISA titers showed some type specificity, whereas none was observed in complement fixation tests. The ELISA is highly sensitive, reproducible, and easily adaptable to the various requirements of clinical and research laboratories.  相似文献   

12.
The enzyme-linked immunosorbent assay (ELISA) was elaborated for the detection of immunoglobulin M (IgM) and IgG antibodies against capsular and O antigens of Haemophilus influenzae. Purified capsular polysaccharide and lipopolysaccharide were used as antigens, with optimal coating concentrations being about 50 and 100 micrograms/ml, respectively. The antibody content was expressed as the highest serum dilution (-log10) showing an absorbance of 0.2 above the background level. The titers of hyperimmune sera (reference sera) ranged between 5 and 7 -log10. The sensitivity of the method was about 80 ng/ml with regard to anticapsular antibodies and 3 to 5 ng/ml with regard to anti-lipopolysaccharide antibodies. For detection of antibodies against capsular polysaccharide in sera obtained after primary immunization, ELISA was about 100-fold more sensitive than the indirect hemagglutination assay, whereas in hyperimmune sera, ELISA was about 10-fold more sensitive than the indirect hemagglutination assay. The sensitivity of ELISA for detecting anticapsular antibodies after primary and booster immunizations was 50-fold higher than that of the bactericidal assay using capsulated bacteria, whereas the sensitivity of the two methods was the same when hyperimmune sera were tested. ELISA performed with lipopolysaccharide as the antigen was about 50- and 150-fold more sensitive than the complement fixation and bactericidal assays tested with noncapsulated variants after primary injection and hyperimmunization, respectively.  相似文献   

13.
A standardized serum bactericidal assay (SBA) is required to evaluate the functional activity of antibody produced in response to Neisseria meningitidis serogroup A and C vaccines. We evaluated assay parameters (assay buffer, target strains, growth of target cells, target cell number, complement source and concentration, and methods for growth of surviving bacteria) which may affect the reproducibility of SBA titers. The various assay parameters and specificity of anticapsular antibody to five serogroup A strains (A1, ATCC 13077, F8238, F9205, and F7485) and four serogroup C strains (C11, G7880, G8050, and 1002-90) were evaluated with Centers for Disease Control and Prevention meningococcal quality control sera. The critical assay parameters for the reproducible measurement of SBA titers were found to include the target strain, assay incubation time, and complement. The resulting standardized SBA was used by 10 laboratories to measure functional anticapsular antibody against serogroup A strains F8238 and serogroup C strain C11. In the multilaboratory study, SBA titers were measured in duplicate for 14 pairs of sera (seven adults and seven children) before and after immunization with a quadrivalent polysaccharide (A, C, Y, and W-135) vaccine. The standardized SBA was reliable in all laboratories regardless of experience in performing SBAs. For most sera, intralaboratory reproducibility was +/- 1 dilution; interlaboratory reproducibility was +/- 2 dilutions. The correlation between median titers (interlaboratory) and enzyme-linked immunosorbent assay total antibody concentrations was high for both serogroup A (r = 0.86; P < 0.001; slope = 0.5) and serogroup C (n = 0.86; P < 0.001; slope = 0.7). The specified assay, which includes the critical parameters of target strain, incubation time, and complement source, will facilitate interlaboratory comparisons of the functional antibody produced in response to current or developing serogroup A and C meningococcal vaccines.  相似文献   

14.
Cytomegalovirus antibodies were measured in human sera by a nuclear anticomplement immunofluorescence test that used as antigen the isolated nucleic of virus-infected fibroblasts cells lysed in distilled water. The method exhibited less nonspecific fluorescence than either a conventional whole-cell anticomplement immunofluorescence test or an indirect fluorescent antibody test applied to the same isolated nuclear substrate. The assay detected 97.5% of 40 antibody-positive sera, compared with 92.5 and 90% detection rates by indirect hemagglutination and complement fixation, respectively. In addition, antibody titers obtained by this technique were significantly higher than those obtained by either indirect hemagglutination (P < 0.02) or complement fixation with a glycine-extract antigen (P < 0.001).  相似文献   

15.
The ability of four serological methods (enzyme-linked immunosorbent assay, single radial haemolysis, micro-immunofluorescence and complement fixation) to detect chlamydial antibodies was compared. Antigen was prepared fromChlamydia trachomatis serotype E. Sixty-two sera known to be positive and 12 negative reference sera were screened. The four tests yielded 71.6 % (53/74) concordant results (Chi-square=14.57,p < 0.01). Samples giving discordant results had only low levels of antibodies. Analysis of results showed a strong correlation between enzyme-linked immunosorbent assay and immunofluorescence (r=0.98), and complement fixation and single radial haemolysis (r=0.75). Antibodies were detected in 97 % of the 62 positive sera by immunofluorescence and in 91 % by enzyme-linked immunosorbent assay, whereas the results for complement fixation and single radial haemolysis were only 69.3 % and 70.9 % respectively. Extrapolation of the regression curve to the abscissae indicated a marginal superiority of immunofluorescence over enzyme-linked immunosorbent assay, although the reading of the results of the former test was more cumbersome. Good linearity was obtained between haemolytic zone diameter and reciprocal serum dilution in single radial haemolysis. Immunofluorescence was found to be the most sensitive and complement fixation the least sensitive of the four tests.  相似文献   

16.
A solid-phase enzyme-linked immunosorbent assay (ELISA) for detection of mumps and parainfluenza type 1 antibodies (immunoglobulin G [IgG] and IgM classes) is described and compared with the conventional complement fixation (CF) test. A highly positive correlation was found between mumps IgG ELISA and the mumps CF test, whereas parainfluenza type 1 IgG ELISA had only a moderate positive correlation with the respective CF test. Mumps IgM antibodies could be demonstrated in all patients with serologically verified and clinically typical (parotitis, meningitis, or orchitis) mumps virus infection, but not in patients with rises in parainfluenza CF titers. Mumps IgM was already present in the acute-phase sera if they were not taken during the first 2 days after onset of disease. Mumps IgM was also found in some paired sera that were taken too late to demonstrate any significant increase in the antibody titers by CF. Therefore, mumps IgM ELISA provides an improvement over the conventional laboratory diagnosis of mumps infection, since the measurement of specific IgM antibodies in a single serum by ELISA is diagnostic, rather than the identification of a fourfold or greater rise in CF antibody titer. An unexpected finding was that parainfluenza type 1 IgM antibodies could not be demonstrated by ELISA in paired sera with rises in parainfluenza CF titers, suggesting a different antibody response from that occurring in mumps infection.  相似文献   

17.
A competitive inhibition enzyme-linked immunosorbent assay (ELISA) was developed to detect antibodies in serum to the protective antigen (PA) and lethal factor (LF) components of anthrax toxin. Current human vaccination schedules with an acellular vaccine induce predictable and lasting antibody titers to PA and, when present in the vaccine, to LF. Live spore vaccine administered to guinea pigs in a single dose conferred significantly better protection than the human vaccines (P less than 0.001), although they elicited significantly lower (P less than 0.0005) anti-PA and anti-LF titers at time of challenge with virulent Bacillus anthracis. Substantial anti-PA and anti-LF titers may not, therefore, indicate solid protective immunity against anthrax infection. The ELISA system was also shown to be capable of detecting anti-PA and anti-LF antibodies in the sera of individuals with histories of clinical anthrax. The advantage of ELISA over the Ouchterlony gel diffusion test and indirect microhemagglutination assay are demonstrated. There was a highly significant degree of correlation between ELISA and the indirect microhemagglutination assay (P less than 0.0005); but ELISA was markedly superior in terms of reproducibility, reliability, specificity, and simplicity in performance and stability of the bound antigen.  相似文献   

18.
A simple dot immunobinding (dot blot) assay procedure has been developed for the detection of antibodies directed against a soluble mycobacterial antigen preparation. This technique was compared with the widely used ELISA, in a study of samples from tuberculous patients. Dot blots were read on a densitometer. The correlation between both assays was excellent (r = 0.91; P less than 0.001); 90% of sera from tuberculous patients were detected using both techniques and a serial two-fold dilution method. Assessments of the end-points of titration curves by reflectometry and simple visual interpretation gave similar results. The dot blot assay is easier to perform and appears to be a practical alternative to ELISA for the detection of anti-mycobacterial antibodies in tuberculous patients.  相似文献   

19.
A simple two stage assay using latex particles as a reaction indicator has been developed for the detection of IgM antibodies to Trichinella spiralis. In the first stage, magnetic polystyrene beads (Dynabeads) coated with T. spiralis antigen were incubated for 30 min with the test serum. After washing, in the second stage, the assay was developed for 1 h using anti-mu-coated latex particles. After sedimentation of the Dynabeads the turbidity of the resultant latex suspension was measured spectrophotometrically at a wavelength of 400 nm. A decrease in turbidity of more than 20% from that of the control, unreacted, suspension was considered positive. Using an IgM phosphorylcholine-binding monoclonal antibody which was reactive with T. spiralis, the sensitivity of the assay was determined to be 110 ng/ml of antibody. This was 20-fold less than the sensitivity achieved in an indirect enzyme-linked immunosorbent assay (ELISA). When the assay was applied to sera obtained from CBA/N or BALB/c mice, which were either normal or immunized against T. spiralis, the expected results were obtained with titers up to 1/640 observed, and confirmed (r = 0.93, P less than 0.001) in the ELISA.  相似文献   

20.
A simplified enzyme-linked immunosorbent assay (ELISA) which utilized commercially available reagents was developed for respiratory syncytial virus (RSV)-specific immunoglobulin G. An analysis of the inherent variation of the assay allowed the setting of strict criteria for determining a significant change in RSV antibodies. The ELISA was more sensitive than the standard complement fixation or microneutralization tests in a carefully studied group of 32 RSV-infected adults. The ELISA correlated closely with complement fixation serological testing in 25 patients. The use of purified antigens might allow the development of a more sensitive ELISA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号