首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PURPOSE: To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. PATIENTS AND METHODS: Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 degrees; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. RESULTS: Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). CONCLUSION: MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema.  相似文献   

2.
AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 degrees; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities.  相似文献   

3.
PURPOSE: To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS: Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40 degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 x 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 x 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using kappa statistics. RESULTS: Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P <.0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION: Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities.  相似文献   

4.
PURPOSE: To determine prospectively the accuracy of a magnetic resonance (MR) perfusion imaging and MR angiography protocol for differentiation of chronic thromboembolic pulmonary arterial hypertension (CTEPH) and primary pulmonary hypertension (PPH) by using parallel acquisition techniques. MATERIALS AND METHODS: The study was approved by the institution's internal review board, and all patients gave written consent prior to participation. A total of 29 patients (16 women; mean age, 54 years +/- 17 [+/- standard deviation]; 13 men; mean age, 57 years +/- 15) with known pulmonary hypertension were examined with a 1.5-T MR imager. MR perfusion imaging (temporal resolution, 1.1 seconds per phase) and MR angiography (matrix, 512; voxel size, 1.0 x 0.7 x 1.6 mm) were performed with parallel acquisition techniques. Dynamic perfusion images and reformatted three-dimensional MR angiograms were analyzed for occlusive and nonocclusive changes of the pulmonary arteries, including perfusion defects, caliber irregularities, and intravascular thrombi. MR perfusion imaging results were compared with those of radionuclide perfusion scintigraphy, and MR angiography results were compared with those of digital subtraction angiography (DSA) and/or contrast material-enhanced multi-detector row computed tomography (CT). Sensitivity, specificity, and diagnostic accuracy of MR perfusion imaging and MR angiography were calculated. Receiver operator characteristic analyses were performed to compare the diagnostic value of MR angiography, MR perfusion imaging, and both modalities combined. For MR angiography and MR perfusion imaging, kappa values were used to assess interobserver agreement. RESULTS: A correct diagnosis was made in 26 (90%) of 29 patients by using this comprehensive MR imaging protocol. Results of MR perfusion imaging demonstrated 79% agreement (ie, identical diagnosis on a per-patient basis) with those of perfusion scintigraphy, and results of MR angiography demonstrated 86% agreement with those of DSA and/or CT angiography. Interobserver agreement was good for both MR perfusion imaging and MR angiography (kappa = 0.63 and 0.70, respectively). CONCLUSION: The combination of fast MR perfusion imaging and high-spatial-resolution MR angiography with parallel acquisition techniques enables the differentiation of PPH from CTEPH with high accuracy.  相似文献   

5.
Although ventilation/perfusion (V/Q) lung scintigraphy is a well-accepted and frequently performed procedure in the diagnosis of pulmonary embolism, there is growing controversy about its relevance, particularly due to the increasing competition between scintigraphy and CT. Even though comparative studies between both modalities have already been performed, their results were highly inconsistent. Remarkably, in most of those studies, conventional planar perfusion scans were compared with tomographic images acquired using state-of-the-art CT scanners-a study design that cannot give impartial results. Hence, the aim of our study was a balanced comparison between V/Q lung scintigraphy and CT angiography using advanced imaging techniques for both modalities. METHODS: A total of 83 patients with suspected pulmonary embolism were examined using V/Q lung scintigraphy in SPECT technique as well as 4-slice spiral CT. Ventilation scans were done using an ultrafine aerosol. Additionally, planar images in 8 views were extracted from the V/Q SPECT datasets. Two experienced referees assessed each of the 3 modalities. The final diagnosis was made at a consensus meeting while taking into account all of the imaging modalities, laboratory tests, clinical data, and evaluation of a follow-up period. RESULTS: In the course of the consensus conference, pulmonary embolism was diagnosed in 37 of the 83 patients (44.6%). Compared with planar scintigraphy, SPECT raised the number of detectable defects at the segmental level by 12.8% (+11 defects; P = 0.401) and at the subsegmental level by 82.6% (+57 defects; P < 0.01). The sensitivity/specificity/accuracy of planar V/Q scintigraphy and V/Q SPECT was 0.76/0.85/0.81 and 0.97/0.91/0.94, respectively, compared with 0.86/0.98/0.93 for multislice CT. CONCLUSION: SPECT and ultrafine aerosols are technical advancements that can substantially improve lung scintigraphy. Using advanced imaging techniques, V/Q scintigraphy and multislice spiral CT both yield an excellent and, in all aspects, comparable diagnostic accuracy, with CT leading in specificity while SPECT shows a superior sensitivity. Even though planar lung scintigraphy yields satisfactory results for a nontomographic modality, it does not compare with tomographic imaging.  相似文献   

6.
Purpose: To assess prospectively the agreement of magnetic resonance (MR) pulmonary perfusion with single-photon emission computed tomography (SPECT) perfusion for perfusion defects down to the subsegmental level in patients with suspected pulmonary embolism (PE).

Material and Methods: In 41 patients with suspected PE, contrast-enhanced MR pulmonary perfusion (3D-FLASH, TR/TE 1.6/0.6 ms) was compared to SPECT perfusion on a per-examination basis as well as at the lobar, segmental, and subsegmental level.

Results: The MRI protocol was completed in all patients, and mean examination time was 3 min 56 s. MR perfusion showed a very high agreement with SPECT (kappa value per examination 0.98, and 0.98, 0.83, and 0.69 for lobar, segmental, and subsegmental perfusion defects, respectively). Of 15 patients with PE, MR perfusion detected 14 cases.

Conclusion: The very high agreement of MR perfusion with SPECT perfusion enables the detection of subtle findings in suspected PE.  相似文献   

7.
PURPOSE: To assess the appropriateness of ventilation-perfusion (V-P) scintigraphic abnormalities as a guide to pulmonary angiography for the diagnosis of pulmonary embolism (PE). MATERIALS AND METHODS: V-P scintigrams and pulmonary angiograms of 104 patients with angiographically proved PE were reviewed by two nuclear medicine physicians and two interventional radiologists. For V-P scintigrams, the lung with the larger amount of perfusion abnormality was determined followed by identification of specific lobes. Pulmonary angiograms were similarly evaluated for lateralization and lobar distribution of PE. Conclusions were initially reached independently and subsequently by consensus. RESULTS: Interobserver agreement for lateralization was 88% (kappa = 0.75) for V-P scintigraphy and 98% (kappa = 0.96) for pulmonary angiography. In 72 patients, V-P scintigrams predicted unilateral embolus; 64 patients underwent pulmonary angiography of the suspected side. Eight patients underwent contralateral angiography only. Of the 64 patients, 61 (95%) had PE on the predicted side at angiography. V-P scintigrams predicted lobar distribution in 55 patients. Of these, PE was found in the predicted lobe in 42 (76%). CONCLUSION: Localization of perfusion abnormalities at V-P scintigraphy provides useful information for the interventional radiologist and serves as an accurate guide for determining the initial approach for pulmonary angiography.  相似文献   

8.
The aim of study was to analyse ventilation and perfusion (V/Q) lung scan findings in a series of Italian patients with Takayasu's arteritis. Eighteen consecutive patients underwent V/Q lung planar scintigraphy and single-photon emission tomography (SPET). Before perfusion scan acquisition was started, a first-pass study with (99m)Tc-macroaggregates of albumin was performed to assess the right ventricular ejection fraction (RVEF). All patients had normal chest X-rays and were symptom free at the time of the investigation. They also underwent echocardiography to evaluate pulmonary artery pressure and in 13 patients respiratory function tests were performed. In four patients, perfusion lung scan was repeated after 1 year. In 10/18 patients (55.5%), 43 unmatched lobar, segmental or subsegmental perfusion defects were found on planar images; ventilation scintigraphy was normal in all cases. On SPET images, 55 defects were found; no defects were found with SPET in the remaining patients who had normal planar images. All patients had normal RVEF and 5/13 patients had mild restrictive-obstructive lung disease. The pulmonary artery pressure was increased in two patients with perfusion defects. In the four patients who had repeat scintigraphy, all defects remained unchanged. The prevalence of lung perfusion abnormalities observed in Italian patients with Takayasu's arteritis is within the range of values reported in other countries, and V/Q planar scintigraphy is sufficient for the screening of patients.  相似文献   

9.
AIM: A number of imaging techniques have been used for the pre-operative assessment of patients for lung volume reduction surgery (LVRS). We evaluated whether data currently acquired from perfusion scintigrams and cine MR of the diaphragm are obtainable from high resolution CT (HRCT) of the thorax. MATERIALS AND METHODS: Thirty patients taking part in a randomized controlled trial of LVRS against maximal medical therapy were evaluated. HRCT examinations (n= 30) were scored for (i) the extent and distribution of emphysema; (ii) the extent of normal pulmonary vasculature; and (iii) diaphragmatic contour, apparent defects and herniation. On scintigraphy, (n= 28), perfusion of the lower thirds of both lungs, as a proportion of total lung perfusion (LZ/T(PERF)), was expressed as a percentage of predicted values (derived from 10 normal control subjects). On cine MR (n= 25) hemidiaphragmatic excursion and coordination were recorded. RESULTS: Extensive emphysema was present on HRCT (60% +/- 13.2%). There was strong correlation between the extent of normal pulmonary vasculature on HRCT and on perfusion scanning (r(s)= 0.85, P< 0.00005). Hemidiaphragmatic incoordination on MR was weakly associated with hemidiaphragmatic eventration on HRCT (P= 0.04). CONCLUSION: The strong correlation between lung perfusion assessed by HRCT and lung perfusion on scintigraphy suggests that perfusion scintigraphy is superfluous in the pre-operative evaluation of patients with emphysema for LVRS.  相似文献   

10.
Perfusion magnetic resonance (MR) imaging is a promising new method for detection of perfusion defects in the diagnosis of pulmonary embolism. In the present study we evaluated the first-pass characteristics of perfusion MR imaging in patients with pneumonia or chronic obstructive pulmonary disease (COPD), frequent differential diagnoses to pulmonary embolism. Dynamic contrast-enhanced MR images of 12 patients with acute pneumonia and 13 patients with exacerbation of COPD were acquired in both the coronal and transaxial planes (an inversion recovery prepared gradient-echo sequence using 0.05 mmol/kg gadodiamide/injection). The MR images and the signal intensity (SI) versus time curves were characterized for each disease entity and compared with normal lung and the findings in pulmonary embolism from our previous study. The perfusion MR images of pneumonia showed distinct regions of increased contrast enhancement; in COPD with signs of emphysema (11 of the 13 COPD patients), the images showed a coarse pattern of reduced contrast enhancement. The SI versus time curves of pneumonia, COPD with signs of emphysema, and normal lung were statistically different, the respective pooled SI values (+/-95% CI) being as follows: mean baseline SI, 20.7 (1.1), 7.4 (0.4), and 8.5 (0.3); mean peak SI, no peak, 12.9 (1.5), and 27 (4.6); and mean max change of SI in percent, 110 (27), 79 (22), and 205 (52). Perfusion MR imaging of pneumonia and COPD with signs of emphysema showed first-pass that were characteristics promising for diagnostic use. Both the MR images and the SI versus time curves were different from the perfusion characteristics in normal lung and pulmonary embolism shown previously.  相似文献   

11.
The aim of study was to analyse ventilation and perfusion (V/Q) lung scan findings in a series of Italian patients with Takayasu's arteritis. Eighteen consecutive patients underwent V/Q lung planar scintigraphy and single-photon emission tomography (SPET). Before perfusion scan acquisition was started, a first-pass study with 99mTc-macroaggregates of albumin was performed to assess the right ventricular ejection fraction (RVEF). All patients had normal chest X-rays and were symptom free at the time of the investigation. They also underwent echocardiography to evaluate pulmonary artery pressure and in 13 patients respiratory function tests were performed. In four patients, perfusion lung scan was repeated after 1 year. In 10/18 patients (55.5%), 43 unmatched lobar, segmental or subsegmental perfusion defects were found on planar images; ventilation scintigraphy was normal in all cases. On SPET images, 55 defects were found; no defects were found with SPET in the remaining patients who had normal planar images. All patients had normal RVEF and 5/13 patients had mild restrictive-obstructive lung disease. The pulmonary artery pressure was increased in two patients with perfusion defects. In the four patients who had repeat scintigraphy, all defects remained unchanged. The prevalence of lung perfusion abnormalities observed in Italian patients with Takayasu's arteritis is within the range of values reported in other countries, and V/Q planar scintigraphy is sufficient for the screening of patients.  相似文献   

12.
AIM: to determine the effectiveness of a new imaging algorithm in the investigation of suspected pulmonary embolism (PE). MATERIALS AND METHODS: A new imaging algorithm for suspected PE was introduced following the installation of a multisection computed tomography (CT) machine at our institution. Before its installation, patients with suspected PE were evaluated with ventilation/perfusion (V/Q) scintigraphy. Subsequently, patients were triaged according to chest radiography (CR) and respiratory history to either lung scintigraphy or CT pulmonary angiography (CTPA). Patients with a normal CR and no history of lung disease were evaluated using perfusion (Q) scintigraphy [ventilation (V) scintigraphy was no longer performed]. Patients with an abnormal CR, asthma or chronic lung disease were evaluated using CTPA. All V/Q images in a continuous 3-year period before the introduction of the new imaging algorithm and all Q images performed in a 3-year period after its introduction were retrospectively reviewed. Imaging reports were categorized into normal, non-diagnostic (low or intermediate probability) or high probability for PE. Patients in the later group who subsequently underwent CTPA, were also reviewed. RESULTS: After the policy change the percentage of normal scintigrams significantly increased (39 to 60%; p<0.001). There was a non-significant increase in the percentage of high probability scintigrams (15 to 18%; p=0.716). Overall the diagnostic yield of lung scintigraphy improved significantly (54 to 78%; p<0.001). CONCLUSION: the diagnostic performance of lung scintigraphy can be improved by careful triage of patients to either Q scintigraphy or CTPA based on clinical history and CR findings. Q scintigraphy remains a valuable diagnostic test in the investigation of suspected PE in carefully selected patients.  相似文献   

13.
Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.  相似文献   

14.
RATIONALE AND OBJECTIVES: To compare hyperpolarized helium-3 (HHe) magnetic resonance imaging (MRI) of the lung with standard Xe-133 lung ventilation scintigraphy. MATERIALS AND METHODS: We performed a retrospective review of 15 subjects who underwent HHe MRI and Xe-133 lung ventilation imaging. Coronal MRI sections were acquired after a single inhalation of HHe gas, and standard posterior planar lung ventilation scintigraphy was performed during continuous breathing of Xe-133 gas. The first breath scintigram of each patient was compared with a composite MR image composed of the sum of the individual MR images and with the individual helium-3 MR images. Ventilation defects on the two imaging modalities were compared for size, conspicuity, and concordance in presence and location. Assessment was done separately for each of four lung quadrants. RESULTS: Comparing the composite HHe MR images with Xe-133 scintigraphy, ventilation defect size, conspicuity and concordance were the same in 67% (40/60), 63% (38/60), and 62% (37/60) quadrants, respectively. Comparing the individual HHe MR image sections with the Xe-133 ventilation scan, there was concordance between the ventilation defects in 27% (16/60) of quadrants. More defects were identified on the individual HHe MR images in 62% (37/60) of quadrants. CONCLUSION: There was good agreement between composite HHe MR image and first breath Xe-133 scintigraphic images, supporting the widely held assumption that HHe MRI likely depicts first breath lung ventilation.  相似文献   

15.
PURPOSE: To compare the accuracy of multi-detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers. MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multi-detector row CT arthrography was performed after tricompartmental injection of 3-6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi-detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted kappa values for interobserver agreement were calculated for both imaging modalities. RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P = .62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P = .02). Interobserver agreement was better for multi-detector row CT arthrography (kappa = 0.37-0.78) than for MR imaging (kappa = -0.33 to -0.10). CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi-detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments.  相似文献   

16.
PURPOSE: To evaluate the ability of noncontrast electrocardiogram (ECG)-gated fast-spin-echo (FSE) perfusion MR images for defining regional lung perfusion impairment, as compared with technetium (Tc)-99m macroaggregated albumin (MAA) single-photon emission computed tomography (SPECT) images. MATERIALS AND METHODS: After acquisition of ECG-gated multiphase FSE MR images during cardiac cycles at selected lung levels in nine healthy volunteers, 11 patients with pulmonary artery-occlusive diseases, and 15 patients with chronic obstructive pulmonary diseases (COPD), the subtracted perfusion-weighted (PW) MR images were obtained from the two-phase images of the minimum lung signal intensity (SI) during systole and the maximum SI during diastole, and were compared with SPECT images. RESULTS: ECG-gated PW images showed uniform but posture-dependent perfusion gradient in normal lungs and visualized the various sizes of perfusion defects in affected lungs. These defect sites were nearly consistent with those on SPECT images, with a significant correlation for the affected-to-unaffected perfusion contrast (r = 0.753; P < 0.0001). These MR images revealed that the pulmonary arterial blood flow in the affected areas of COPD was relatively preserved as compared with pulmonary artery-occlusive diseases, and also showed significant decrease in blood flow, even in the areas with homogeneous perfusion on SPECT images in patients with focal pulmonary emphysema. CONCLUSION: This noninvasive MR technique allows qualitative and quantitative assessment of lung perfusion, and may better characterize regional perfusion impairment in pulmonary artery-occlusive diseases and COPD.  相似文献   

17.
Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy.Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0–90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference.Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy.Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.  相似文献   

18.

Objective

Aims were (1) to determine the diagnostic accuracy of Dual Energy CT (DECT) in the detection of perfusion defects and (2) to evaluate the potential of DECT to improve the sensitivity for PE.

Methods

15 patients underwent Dual Energy pulmonary CT angiography (DE CTPA) and a combination of lung perfusion SPECT/CT and ventilation scintigraphy. CTPA and DE iodine distribution maps as well as perfusion SPECT/CT and inhalation scintigrams were reviewed for pulmonary embolism (PE) diagnosis. DECT and SPECT perfusion images were assessed regarding localization and extent of perfusion defects. Diagnostic accuracy of DE iodine (perfusion) maps was determined with reference to SPECT/CT. Diagnostic accuracies for PE detection of DECT and of SPECT/CT with ventilation scintigraphy were calculated with reference to the consensus reading of all modalities.

Results

DE CTPA had a sensitivity/specificity of 100%/100% for acute PE, while the combination of SPECT/CT and ventilation scintigraphy had a sensitivity/specificity of 85.7%/87.5%. For perfusion defects, DECT iodine maps had a sensitivity/specificity of 76.7% and 98.2%.

Conclusion

DECT is able to identify pulmonary perfusion defects with good accuracy. This technique may potentially enhance the diagnostic accuracy in the assessment of PE.  相似文献   

19.
PURPOSE: To prospectively determine if lung function as assessed with oxygen-enhanced magnetic resonance (MR) imaging correlates with postsurgical lung function in patients with lung cancer, as compared with quantitative and qualitative findings of computed tomography (CT) and scintigraphy. MATERIALS AND METHODS: Study received institutional review board approval, and informed patient consent was obtained. Thirty consecutive patients (16 men and 14 women, aged 44-81 years; mean age, 65 years) considered candidates for lung resection underwent oxygen-enhanced MR imaging, CT, perfusion scintigraphy, and measurement of forced expiratory volume in 1 second (FEV1). A respiratory-synchronized inversion-recovery half-Fourier single-shot turbo spin-echo MR sequence was used for data acquisition. Correlation of postsurgical lung function (postsurgical FEV1) as determined with oxygen-enhanced MR imaging (FEV1MR), quantitative assessment with CT (FEV1Quant), qualitative assessment with CT (FEV1Qual), and perfusion scintigraphy (FEV1PS) was conducted with actual postsurgical FEV1, and the limits of agreement of each were determined with Bland-Altman analysis. RESULTS: Correlation between postsurgical FEV1MR and actual postsurgical FEV1 values was excellent (r2= 0.81, P < .001); it was better than that of FEV1Qual (r2= 0.76) and FEV1PS (r2= 0.77) and similar to that of FEV1Quant (r2= 0.81) values. The limits of agreement of FEV1MR were between -9.9% and 10.9%. CONCLUSION: Oxygen-enhanced MR imaging can be used to predict posturgical lung function in patients with lung cancer, similar to quantitative CT.  相似文献   

20.
The present study assesses the detectability of perfusion defect and the influence of breathhold on pulmonary magnetic resonance (MR) perfusion imaging using contrast-enhanced thick-slice two-dimensional (2D) fast gradient-echo sequence compared with three-dimensional (3D) fast spoiled gradient-recalled sequence. Dynamic studies were performed in 16 patients. MR perfusion images were interpreted by two independent observers using perfusion scintigraphy as the reference standard. The patients were divided into two groups according to the duration of holding the breath measured during MR imaging. The sensitivity and specificity of 2D MR perfusion imaging in detecting perfusion defects were 93% and 94%, respectively, while those of 3D MR perfusion imaging were 89% and 85%, respectively. The diagnostic accuracy of 2D MR perfusion imaging was significantly higher than that of 3D MR perfusion imaging (P < 0.05) among those who could not hold their breath. Therefore, 2D MR perfusion imaging offers promise for evaluating pulmonary perfusion even among patients who cannot hold their breath.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号