BACKGROUND: Tibial tunnel preparation may contribute to improved soft tissue graft fixation. HYPOTHESIS: Step dilation produces greater tunnel wall bone volume than does extraction drilling and increases fixation strength. Bioabsorbable interference screw divergence decreases fixation strength, regardless of tunnel preparation method. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty porcine tibias were divided into 2 groups of 10 with matching mean apparent bone mineral density. One group received 9-mm-diameter extraction-drilled tunnels, and the other group received 7-mm-diameter extraction-drilled tunnels followed by step dilation to 9 mm. High-resolution quantitative computerized tomography scans and voxel analysis techniques determined tunnel wall bone volume fraction. Screws secured 8.5-mm-diameter porcine grafts in the tunnels. Repeat scans were used to determine screw divergence. Cyclic loading was performed in a servohydraulic device before load to failure testing. RESULTS: The step dilation group had greater tunnel wall bone volume/total volume than did the extraction drilled group; however, a significant increase in fixation strength was not detected. Specimens with screw divergence angles less than 15 degrees had superior fixation and insertion torques compared with specimens with angles 15 degrees or more. Screw divergence correlated more strongly with fixation strength than did mean apparent bone mineral density or screw insertion torque. CONCLUSION: Step dilation increased tunnel wall bone volume/total volume, but fixation strength did not improve. Screw divergence >or=15 degrees decreases graft-bone tunnel fixation whether or not step dilation is performed. CLINICAL RELEVANCE: Screw alignment plays a greater role in anterior cruciate ligament graft fixation than does extraction drilling or step dilation tunnel preparation methods in healthy bone.  相似文献   

2.
The purpose of this study was to determine whether bone mineral density of the host bone, measured using conventional dual photon absorptiometry techniques, and insertion torque can predict part of the ultimate failure strength of interference screw fixation of quadrupled hamstring tendon grafts. The semitendinosus and gracilis tendons were harvested from 10 human cadaveric knees, mean age 66.5 years (range, 53 to 81). The bone tunnel was sized within 0.5 mm of the graft. The graft was fixed with a biodegradable screw (7 x 25 mm for the femur, and 9 x 25 mm for the tibia) directly against the tendon and at the joint surfaces. Tibial fixation and femoral fixation were tested to failure using a materials testing system. Bone mineral density was measured in the metaphyseal region of the tibia and femur. The results of multiple regression analyses showed that both insertion torque and bone mineral density were related to the maximum load the graft withstood. These two variables explained 77.1% of the maximum load observed. We concluded that bone mineral density measurements of the host bone site are an important determinant of postoperative graft strength and thus have an important, but previously unrecognized, clinical role in establishing individual postsurgery rehabilitation protocols. Insertion torque in this study was a useful predictor of graft fixation strength.  相似文献   

3.
Initial strength of quadrupled hamstring tendon grafts fixed with titanium interference screws was assessed in 30 pairs of porcine tibiae. Bone tunnels were drilled with either compaction drilling (stepped routers) or conventional extraction drilling (cannulated drill bits). Fifteen pairs of specimens were subjected to a single-cycle load-to-failure test, while the rest underwent a cyclic-loading test to further assess the quality of the fixation. No significant difference between the two drilling techniques was found with regard to yield load, displacement at yield load, stiffness, or mode of failure. Porcine trabecular bone mineral density was determined using peripheral quantitative computed tomography and compared with that of young women and men at a site corresponding to that of the tibial bone drill hole of an anterior cruciate ligament reconstruction. There was a significant difference between the two species (210 +/- 45 mg/cm(3) in porcine tibial bone versus 129 +/- 30 mg/cm(3) in women and 134 +/- 34 mg/cm(3) in men), suggesting that porcine knee specimens may have limitations in studies of graft fixation in anterior cruciate ligament reconstruction. We found no difference between extraction and compaction drilling in initial fixation strength of a hamstring tendon graft for anterior cruciate ligament reconstruction using a porcine model.  相似文献   

4.
BACKGROUND: Compaction of the bone tunnel walls has been proposed to increase the fixation strength of soft tissue grafts fixed with an interference screw in anterior cruciate ligament reconstructions. HYPOTHESIS: Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft in comparison with conventional extraction drilling. STUDY DESIGN: Randomized experimental study. METHODS: Initial fixation strength of quadrupled hamstring tendon grafts fixed with bioabsorbable interference screws was assessed in 22 pairs of human cadaveric tibiae. Bone tunnels were drilled with either a compaction drill or a conventional extraction drill. Specimens underwent a cyclic-loading test and the surviving specimens were then loaded to failure in a single-cycle load-to-failure test. Trabecular bone mineral density at the site corresponding to the actual site of the tibial bone tunnel was determined by using peripheral quantitative computed tomography. RESULTS: During the cyclic-loading test, no significant stiffness or displacement differences were observed between the two drilling techniques. Three specimens failed in the compaction-drilling group, whereas there were no failures in the extraction-drilling group. In the subsequent single-cycle load-to-failure test, no significant differences between the two drilling techniques were found with regard to displacement at yield load, stiffness, or mode of failure. There was no significant difference in trabecular bone mineral density between the two groups. CONCLUSIONS: Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft compared with conventional extraction drilling.  相似文献   

5.
BACKGROUND: For a tendon graft to function as an anterior cruciate ligament, the tendon must heal to the bone tunnel. We studied the effect of 4 weeks of implantation on the strength and stiffness of a tendon in a bone tunnel using two different fixation devices in an ovine model. HYPOTHESIS: The type of fixation device in anterior cruciate ligament reconstruction may affect early healing, which can be measured as the strength and stiffness of a tendon in a bone tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: An extraarticular tendon graft reconstruction was performed in ovine tibias. The graft was fixed with either a bioresorbable interference screw or a WasherLoc. After 4 weeks of implantation the strength and stiffness of the complex and the tendon graft-bone tunnel interface were determined by incrementally loading specimens to failure. RESULTS: For the interference screw, the strength deteriorated 63% and the stiffness deteriorated 40%. For the WasherLoc, the strength was similar and the stiffness improved 136%. CONCLUSIONS: The type of fixation device determines whether the strength and stiffness of a tendon in a bone tunnel increases or decreases after implantation. Clinical Relevance: The pace of rehabilitation may need to be adjusted based on the type of fixation device used to secure a soft tissue graft.  相似文献   

6.
BACKGROUND: Tibial fixation of hamstring tendon grafts has been the weak link in anterior cruciate ligament reconstruction. HYPOTHESIS: Use of a central four-quadrant sleeve and screw provides superior fixation when compared with standard interference screw fixation. STUDY DESIGN: Controlled laboratory study. METHODS: In eight pairs of cadaveric knees each anterior cruciate ligament was reconstructed using either an interference screw or a central sleeve and screw on the tibial side. The specimens were then subjected to cyclic loading followed by a load-to-failure test. RESULTS: The load required to cause 1 and 2 mm of graft laxity, defined as the separation of the femur and the tibia at the points of graft fixation, was significantly greater with the sleeve and screw than with the interference screw (at 2 mm: sleeve and screw, 216.1 +/- 30.1 N; interference screw, 167.0 +/- 33.2 N). The force at initial slippage for each of the graft strands was significantly higher with use of the central sleeve and screw. CONCLUSIONS: The four-quadrant sleeve and screw device may provide greater surface area for healing of hamstring tendon grafts and allow equal tensioning of graft strands before fixation. These factors are associated with increased strength of fixation and reduced laxity of the graft after cyclic loading. Clinical Relevance: Use of the central four-quadrant sleeve and screw system offers increased strength of fixation in anterior cruciate ligament reconstruction with hamstring tendon graft.  相似文献   

7.
BACKGROUND: The literature provides little biomechanical data about femoral fixation of hamstring grafts in posterior cruciate ligament reconstruction. HYPOTHESIS: A hybrid fixation technique with use of an undersized screw has sufficient strength to provide secure fixation of posterior cruciate ligament grafts. Additional aperture fixation with a biodegradable interference screw can prevent graft damage that might be caused by an acute angle on the edge of the femoral tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: In part 1, extracortical fixation of posterior cruciate ligament reconstructions with quadrupled porcine flexor digitorum grafts to simulate human hamstring grafts was compared with hybrid fixation methods using 6-, 7-, and 8-mm screws. Groups were tested in cycling loading with the load applied in line with the bone tunnel. In part 2, extracortical fixation was compared with hybrid fixation using a 1-mm undersized screw anterior and posterior to the graft. Structural properties and graft abrasion were evaluated after cyclic loading with the load applied at 90 degrees to the tunnel. In each group, 8 porcine knees were tested. RESULTS: In part 1, stiffness, maximum load, and yield load were significantly higher for hybrid fixation than for extracortical fixation. Hybrid fixation with an 8-mm screw resulted in higher yield load than with a 7-mm screw. In part 2, graft laceration was more pronounced in specimens with extracortical fixation than with hybrid fixation. Posterior screw placement was superior to the anterior position. CONCLUSION: For all parameters, hybrid fixation with an interference screw provided superior structural results. No relevant disadvantages of undersized screws could be found. Graft damage due to abrasion at the edge of the femoral bone tunnel was reduced by use of an interference screw. The posterior screw placement seems favorable. CLINICAL RELEVANCE: Hybrid fixation of hamstring grafts in posterior cruciate ligament reconstruction is superior to extracortical fixation alone with no relevant disadvantages of undersized screws. The results raise the suspicion of an acute angle effect of the femoral bone tunnel.  相似文献   

8.
Initial tibial fixation strength is the weak link after anterior cruciate ligament reconstruction with a quadrupled hamstring tendon graft fixed with bioabsorbable interference screws. The purpose of this study was to determine the biomechanical differences between 28-mm and tapered 35-mm interference screws for tibial fixation of a soft tissue graft in 16 young cadaveric tibias. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine aligned with the tibial tunnel to simulate a worst-case scenario. The mode of failure was graft slippage past the screw in all but one of the specimens. The mean maximum load at failure of the 28-mm screw was 594.9 +/- 141.0 N, with mean displacement at failure of 10.97 +/- 2.20 mm. The mean maximum load at failure of the 35-mm screw was 824.9 +/- 124.3 N, with a mean displacement to failure of 14.38 +/- 2.15 mm. The 38% difference in mean maximal load at failure was significant. Important variables in hamstring tendon graft fixation within a bone tunnel include bone mineral density, dilatation, gap size, screw placement, and screw width and length. Attention to these variables will help to provide secure graft fixation during biologic incorporation throughout the rehabilitation period.  相似文献   

9.
BACKGROUND: Interference screw fixation of the graft in anterior cruciate ligament reconstruction is considered the gold standard, but limited clinical experience suggests that transcondylar fixation is equally effective. PURPOSE: To compare transcondylar and interference screw fixation. STUDY DESIGN: Ex vivo biomechanical study. METHODS: Twenty pairs of unembalmed knees underwent anterior cruciate ligament reconstruction with patellar tendon autografts. In 1 knee of each pair, the bone plug was stabilized in the femoral tunnel with standard interference screws; in the other knee, transcondylar screws were used. Testing to failure occurred immediately or after 1000 cycles of sinusoidal loading (30 to 150 N) (20 paired reconstructions each). Fixation stiffness, strength, graft creep, displacement amplitude, and change in amplitude were measured and compared (repeated measures anaylsis of variance with Tukey test; P <.05). RESULTS: There was no significant difference in acute strength, maximum load within 3 mm, or stiffness between transcondylar fixation (410 +/- 164 N, 183 +/- 93 N, and 49.6 +/- 28 N/mm, respectively) and interference fixation (497 +/- 216 N, 206 +/- 115 N, and 61 +/- 37.8 N/mm, respectively). Similarly, there was no significant difference in cyclic strength, maximum load within 3 mm, or stiffness between transcondylar fixation (496 +/- 214 N, 357 +/- 82.9 N, and 110 +/- 27.4 N/mm, respectively) and interference fixation (552 +/- 233 N, 357 +/- 76.2 N, and 112 +/- 26.8 N/mm, respectively). Predominant modes of failure were bone plug pullout (transcondylar fixation) and tendon failure or bone plug fracture (interference fixation). CONCLUSIONS: Transcondylar screw fixation of the patellar tendon autograft into the femoral tunnel performed mechanically as well as interference screw fixation. CLINICAL RELEVANCE: The results suggest that transcondylar and interference screws provide similar fixation for anterior cruciate ligament reconstruction.  相似文献   

10.
BACKGROUND: Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS: There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Forty-eight anterior cruciate ligament reconstructions were performed using immature porcine femurs stripped of soft tissue and doubled-over porcine flexor digitorum profundus tendon grafts. Specimens were randomized to bioabsorbable or titanium interference screw fixation. Specimens were randomized to one of three pull angles (0 degrees , 30 degrees , 60 degrees ) representing loading at different knee flexion angles (n = 8/group). Reconstructed ligaments were tensioned to 10 N followed by 200 loading cycles between 10 and 150 N and a final failure test. Construct elongation (mm) at 100 and 200 cycles and failure load (N) were analyzed using a 2-way analysis of variance (P < .05). RESULTS: Screw material interacted significantly with graft tension angle, as the bioabsorbable screw specimens demonstrated significantly greater fixation strength when tensioned at greater angles. Specimens fixed with bioabsorbable screws showed significantly less elongation at both 100 and 200 cycles and significantly greater failure load compared with titanium screws. CONCLUSION: Bioabsorbable interference screws acutely have increased fixation strength compared with titanium interference screws for anterior cruciate ligament grafts loaded at greater tension angles. CLINICAL RELEVANCE: The strength of anterior cruciate ligament reconstruction fixation increases with increasing divergence between the tension angle and femoral tunnel, a condition seen when the knee approaches full extension.  相似文献   

11.
The purpose of this study is to evaluate the mechanical properties of a graft fixation using a small diameter soft tissue interference screw and analyze the factors affecting the fixation strength. Forty porcine knees were used. A bone tunnel, either 4.5 mm (n=40) or 5.0 mm (n=40) in diameter, was created in the bone block obtained from the proximal tibia or the distal femur. A patella–patellar tendon specimen with varied width was harvested, and the distal end of the patellar tendon was fixed within the bone tunnel using a small diameter soft tissue interference screw (4×15 mm). Then, the patella–patellar tendon-bone block complex was loaded until failure occurred and the maximum load was measured. As potential influential factors on the fixation strength, the insertion torque, bone mineral density of the bone block, and graft/tunnel cross-sectional area ratio (GTR) of each specimen were calculated. A significant correlation between the maximum failure load and the insertion torque was demonstrated. The quadratic regression analysis showed a statistically significant correlation between the failure load and the GTR. Optimal GTR for achieving high fixation strength was approximately 80%. When used in appropriate conditions, the mean failure load was 177 N for the 4.5 mm screw and 180 N for the 5 mm screw. The use of a small diameter interference screw for the fixation of a tendon graft to a bone is clinically feasible. Our research showed that the selection of appropriate fitting conditions is an important factor for optimizing the properties of the fixation.  相似文献   

12.
BACKGROUND: The weakest points in hamstrings anterior cruciate ligament reconstruction are its points of fixation, especially on the tibial side. Methods for graft fixation to bone should be strong enough to avoid failure, stiff enough to restore load-displacement response, and secure enough to resist slippage under cyclic loading. HYPOTHESIS: Biomechanical properties of the interference screw can be improved by reinforcing the walls of the tunnel with a metal spiral (Evolgate fixation). STUDY DESIGN: Controlled laboratory study. METHODS: Three paired tests were performed using common digital extensor bovine tendons fixed to porcine tibias with interference screw, Intrafix, and Evolgate; critical graft fixation conditions were simulated by applying subsequent cycles to the graft before loading the graft until failure. RESULTS: The strength, stiffness, and resistance to slippage of the Evolgate were significantly higher than those of the interference screw; the ultimate failure load of the Evolgate was significantly higher than that of the Intrafix (1058+/-130 N and 832+/-156 N, respectively; P=.02). No statistically significant differences were found between Evolgate and Intrafix regarding the stiffness and slippage under cyclic load. CONCLUSION: Evolgate fixation seems to be stronger, stiffer, and more resistant to slippage than is interference screw fixation of similar length, and it is stronger but not stiffer than Intrafix. CLINICAL RELEVANCE: The Evolgate provides structural properties that seem to be appropriate for an intensive rehabilitation after anterior cruciate ligament reconstruction using a doubled semitendinosus and gracilis graft.  相似文献   

13.
We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable poly-(L-lactide) interference screws with a diameter of 7, 8, and 9 mm and a length of 23 and 28 mm were used. We examined results in three groups of 10 specimens each: group 1, screw diameter equaled graft diameter and screw length was 23 mm; group 2, screw diameter equaled graft diameter plus 1 mm and screw length was 23 mm; group 3, screw diameter equaled graft diameter and screw length was 28 mm. The mean pull-out forces in groups 1, 2, and 3 were 367.2+/-78 N, 479.1+/-111.1 N, and 537.4+/-139.1 N, respectively. The force data from groups 2 and 3 were significantly higher than those from group 1. These results indicate that screw geometry has a significant influence on hamstring tendon interference fit fixation. Increasing screw length improves fixation strength more than oversizing the screw diameter. This is important, especially for increasing tibial fixation strength because the tibial graft fixation site has been considered to be the weak link of such a reconstruction.  相似文献   

14.
BACKGROUND: Bone morphogenetic proteins induce new bone both in patients with bone defects and at extraskeletal sites in animals. After anterior cruciate ligament rupture, tendon graft fixation into a bone tunnel is a widely used method for anterior cruciate ligament reconstruction. HYPOTHESIS: Bone morphogenetic protein-7 applied to the bone-tendon interface enables better integration of a free tendon graft into the surrounding bone. STUDY DESIGN: Controlled laboratory study. METHODS: The anterior cruciate ligament was reconstructed using a free tendon graft in the right rear knees of 30 one-year-old male sheep. Recombinant human bone morphogenetic protein-7 (25 microg) was applied randomly to the bone-tendon interface in 15 animals, and a vehicle was applied in 15 control animals. At 3 weeks, 10 animals from each group were sacrificed, and the remaining sheep were sacrificed at 6 weeks after surgery. Subsequently, histologic analysis and mechanical testing were performed. In another group of 20 sheep, the same procedure was used and mechanical testing was performed after 3 weeks. RESULTS: More new bone was formed at the bone-tendon interface in the knees treated with bone morphogenetic protein-7 as compared histologically with similar areas in control animals, creating areas of dense trabecular network with significantly greater invasion of the tendon fibrous tissue into the bone marrow space. Mechanical testing showed greater strain resistance to force (368 N) in the knees treated with bone morphogenetic protein-7 than in control specimens (214 N). There was no difference between mechanical testing of samples from 3 and 6 weeks after surgery. CONCLUSION: Bone morphogenetic protein-7 promotes complete tendon graft integration into the newly formed surrounding trabecular bone in the reconstruction of the anterior cruciate ligament. Clinical Relevance: Bone morphogenetic protein-7 in tendon graft integration might be successfully used in reconstructive surgery of ligaments.  相似文献   

15.
In this study of bioabsorbable screw fixation of free tendon grafts used in anterior cruciate ligament reconstruction, we performed load-to-failure and cyclic loading of tendon fixation in porcine bone. Bone density measurements from dual photon absorptometry scans were obtained to correlate bone density with fixation failure. The average density of porcine bone (1.42 g/cm2) was similar to that of young human bone (1.30 g/cm2) and significantly higher than that of elderly human cadaveric bone specimens (0.30 g/cm2). Cyclic loading was performed on free tendon grafts fixed with a bioabsorbable screw alone and on grafts fixed with a bioabsorbable screw and an anchor (polylactic acid ball or cortical bone disk). Stiffness of fixation increased substantially with the addition of a cortical bone disk anchor or polylactic acid ball compared with the interference screw alone. Tensile fixation strength of central quadriceps free tendon and hamstring tendon grafts were significantly superior in porcine bone of density similar to young human bone than in elderly human cadaveric bone. The bioabsorbable interference screw yielded loads at failure comparable with traditional bone-tendon-bone and hamstring tendon fixation when controlled for bone density. The addition of a cortical bone disk anchor provided the most optimal fixation of free tendon with the bioabsorbable screw and reduced slippage with cyclic loading to a very low level.  相似文献   

16.
BACKGROUND: The results of revision anterior cruciate ligament reconstruction are limited in the current literature, and no studies have previously documented the outcome of revision anterior cruciate ligament reconstruction using solely hamstring tendon grafts. HYPOTHESIS: Revision anterior cruciate ligament reconstruction with 4-strand hamstring tendon graft affords acceptable results and is comparable to reported outcomes with the bone-patellar tendon-bone graft. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Fifty-seven consecutive revision anterior cruciate ligament reconstructions with the hamstring tendon graft and interference screw fixation were assessed a mean time of 89 months (range, 60-109 months) after surgery. Assessment included the International Knee Documentation Committee knee ligament evaluation, instrumented laxity testing, and radiologic examination. RESULTS: Of the 50 knees reviewed, 5 (10%) had objective failure of the revision anterior cruciate ligament reconstruction. Of the 45 patients with functional grafts, knee function was normal or nearly normal in 33 patients (73%). An overall grade of normal or nearly normal was found in 56% of patients. The mean side-to-side difference on manual maximum testing was 2.5 mm (range, -1 to 4 mm). Degenerative changes on radiographs were identified in 23% of patients at the time of surgery, increasing to 56% of patients at review. The status of the articular cartilage at the time of revision surgery was the most significant contributor to successful outcome. CONCLUSION: Revision anterior cruciate ligament reconstruction with hamstring tendon graft and interference screw fixation affords acceptable results at a minimum of 5 years' follow-up. Good objective results can be obtained, but subjectively, the results appear inferior to those of primary anterior cruciate ligament reconstruction in the literature, which may be related to the high incidence of articular surface damage in this patient population. We recommend that, when available, hamstring tendon autografts should be considered for revision anterior cruciate ligament reconstruction.  相似文献   

17.
A failure analysis of interference screw fixation was performed to test the hypothesis that bovine and/or elderly human cadavers are appropriate models for bonepatellar tendon-bone anterior cruciate ligament (ACL) reconstruction fixation studies. Failure mode is an important criterion for validating experimental models. The bovine, young human, and elderly human failure loads were 799±261 N, 655±186 N, and 382±118 N, respectively, and the failure modes were 75%, 69%, and 30% tissue failures, respectively. The similarities between the bovine and young human models in failure loads and failure modes indicate that bovine models are appropriate for ACL reconstruction fixation studies. The statistically significant differences between the young human and elderly human models in failure loads and failure modes indicate that elderly human cadavers are not an appropriate model for ACL reconstruction fixation studies. The differences in failure modes are consistent with previous studies using elderly human cadavers in which the predominant failure mode was bone block pullout. The tissue failures observed in the bovine and young human models contradict previous studies suggesting fixation strength is the weakest link in bone-patellar tendon-bone ACL reconstruction. Results of linear regression modeling showed statistically significant correlations between insertion torque and failure load (R 2=0.44,P<0.0001) and interference (defined as the screw outer thread diameter minus the tunnel-bone block gap) and insertion torque (R 2=0.18,P=0.003) when data from all models was combined. Results for the bovine model multiple regression showed a statistically significant regression of insertion torque (linear) and interference (quadritic) versus failure load (R 2=0.56,P=0.02). Regression slopes for screw diameter (P=0.52) and gap size (P=1.00) were not statistically significant. These results indicate that insertion torque and interference are independent predictors of failure load and should be included in future interference screw studies in addition to bone block dimensions, tunnel size, gap size, and screw diameter. Clinicians may consider using insertion torque and interference as indicators of postoperative graft fixation regarding rehabilitation decisions.  相似文献   

18.
BACKGROUND: There is some confusion about the relationship between the tension placed on the graft and the joint position used in the fixation of anterior cruciate ligament grafts. This is because of deficiency in accurate basic science about this important interaction in the normal and reconstructed anterior cruciate ligament. HYPOTHESIS: If the normal femoral attachment of the anterior cruciate ligament can be preserved and the tibial insertion isolated and tested, an accurate force-flexion curve of the human anterior cruciate ligament can be mapped out and used as a standard for proper graft tensioning protocols in anterior cruciate ligament reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: In 10 fresh-frozen human cadaveric knees, an isolated bone plug containing the tibial anterior cruciate ligament insertion was connected with a custom-made tensiometer. The knees were moved through the whole range of motion; the starting point chosen was an anterior cruciate ligament tension of 10 N, which was applied at 10 degrees of knee flexion and resulted in a baseline curve. This curve was compared with the results recorded when the starting point was below the baseline curve, similar to, or above it. RESULTS: The anterior cruciate ligament showed low tension close to slackness in midflexion after starting with 10 N at 10 degrees of flexion. Starting points below the baseline curve shifted the whole curve downward; those above the baseline curve increased the force in the anterior cruciate ligament, resulting in a tight anterior cruciate ligament in midflexion. CLINICAL RELEVANCE: The normal anterior cruciate ligament shows a physiological laxity in midflexion. This study gives guidelines for tensioning protocols in anterior cruciate ligament grafts to replicate the force-flexion curve characteristics of the normal anterior cruciate ligament.  相似文献   

19.
BACKGROUND: Bone-patellar tendon-bone graft has been the most commonly used graft material in anterior cruciate reconstructions, but there has been increasing use of hamstring tendon grafts. However, no existing clinical studies show adequate support for the choice of one graft over the other. HYPOTHESIS: Hamstring tendons are equally as good as patellar tendon in anterior cruciate ligament reconstructions. STUDY DESIGN: Prospective randomized clinical trial. METHODS: Ninety-nine patients with laxity caused by a torn anterior cruciate ligament underwent arthroscopically assisted reconstruction with graft randomization according to their birth year. Grafts were either bone-patellar tendon-bone with metal interference screw fixation or double-looped hamstring tendons with metal plate fixation. There were no significant differences between the two groups preoperatively or at operation. Standard rehabilitation included immediate postoperative mobilization without a knee brace, protected weightbearing for 2 weeks, and return to full activity at 6 to 12 months. RESULTS: Forty-three patients in the patellar tendon group and 46 patients in the hamstring tendon group were available for clinical evaluation at a minimum of 21 months after surgery. No statistically significant differences were seen with respect to clinical and instrumented laxity testing, International Knee Documentation Committee Score ratings, isokinetic muscle torque measurements, and Kujala patellofemoral, Lysholm, and Tegner scores. CONCLUSION: Equal results were seen for patellar and hamstring tendon autograft anterior cruciate ligament reconstructions at 2 years after surgery. Both techniques seem to improve patients' performance.  相似文献   

20.
BACKGROUND: The security of the graft fixation is an important factor of anterior cruciate ligament reconstruction, especially in the early postoperative period. HYPOTHESIS: The femoral press-fit fixation technique is a safe, alternative technique for the fixation of the bone-patellar tendon-bone graft. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Between January 1, 1998, and June 30, 2002, 285 patients, with a mean age of 29.1 years, underwent operation and observation in our department. All patients had arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft with femoral press-fit and tibial interference screw fixation. The mean follow-up period was 35.8 months (range, 24-77 months). During each patient's evaluation, a physical examination, a subjective evaluation, the International Knee Documentation Committee and Lysholm scores, KT-1000 arthrometer testing, and radiological evaluation were performed. The paired Student t test or chi(2) test was used for statistical analysis. RESULTS: According to the International Knee Documentation Committee score, 241 patients (85%) had good (46 normal and 195 nearly normal) results, whereas 39 patients had abnormal and 5 patients had severely abnormal overall results. The preoperative mean Lysholm score was 63.5 +/- 12.7 points. At the final examination, the mean value was 93.5 +/- 7.8 points (P < .01). One hundred ninety-seven athletes could return to their previous sports activity level, whereas 13 patients gave up their sports career. The KT-1000 arthrometer results showed a side-to-side difference of 1.91 +/- 2.1 mm at the maximum manual strength tests. CONCLUSION: The femoral press-fit fixation is an alternative fixation method for the bone-patellar tendon-bone graft and provides good stability for the anterior cruciate ligament reconstruction. The use of press-fit fixation technique avoids most interference screw or other hardware-induced complications at the femoral side.  相似文献   