首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

Ablative oncological surgery to treat head-and-neck cancer often triggers a requirement for jaw reconstruction. Modern surgical procedures using free microvascular flaps afford acceptable outcomes in terms of restoration of bony and soft tissue defects. A fibula free flap is often the preferred flap, as the bone length is considerable and a two-surgeon approach is possible. Dental implants play important roles in functional rehabilitation. Our aim was to evaluate the survival of dental implants placed in reconstructed areas after transfer of fibula tissue to the jaw.

Materials and methods

We retrospectively studied 34 patients who underwent ablative tumour surgery and jaw reconstruction using osteocutaneous fibula free flaps and who then received dental implants. We evaluated implant survival and success, survival of the fibula flap, and clinical and radiographic data.

Results

We included 34 patients, 23 of whom were diagnosed with squamous cell carcinoma. In total, 134 dental implants were inserted in transferred fibula bone. The cumulative implant survival rate was 81%. The survival rate of the 34 fibula flaps transplanted after surgical reconstruction was 97%.

Conclusion

The insertion of endosseous implants after jaw reconstruction using vascularised fibula tissue yields successful dental rehabilitation in patients with oral cancers.  相似文献   

2.

Purpose

The preservation of peri-implant bone is one requirement for long-term success of dental implants. The purpose of this study was to evaluate the impact of subcrestal placement on the crestal bone level of immediate versus delayed placed implants after loading.

Materials and methods

In this retrospective study, data of 159 patients who received 330 implants was analyzed. Implants were placed subcrestally, crestally or supracrestally into fresh sockets or healed sites. Vertical bone level height was assessed radiographically and implants were followed up annually. The influence of patient and implant related risk factors for peri-implant bone loss was evaluated using a linear mixed model.

Results

Depth of implant placement was significantly correlated with peri-implant bone loss (P = 0.001, 95% CI). Least effective loss of crestal bone was determined when implants were placed between 1 mm and 1.99 mm subcrestally. Smoking significantly enhanced the risk of peri-implant bone loss (P = 0.04, 95% CI). Immediate implant placement was not positively correlated with peri-implant bone loss (P = 0.51, 95% CI).

Conclusion

Within the limits of this study, implant placement 1.08 mm subcrestally may be recommendable in order to avoid supracrestal expositions of platform-switched titanium implants over time.  相似文献   

3.

Statement of problem

In recent years, the use of resin-matrix ceramics and polyetheretherketone (PEEK) abutments has been suggested to absorb excessive stresses on dental implants. However, only a few studies have evaluated the effect of these materials on stress distribution in implants and peripheral bone structure.

Purpose

The purpose of this finite element analysis was to evaluate the biomechanical behaviors of resin-matrix ceramics and PEEK customized abutments in terms of stress distribution in implants and peripheral bone.

Material and methods

Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created by using the standard tessellation language (STL) data of original implant components. An anatomic customized abutment and a maxillary right second premolar crown were then modeled over the titanium base abutment. A bone block representing the maxillary right premolar area was created, and the implant was placed in the bone block with 100% osseointegration. Six different models were created according to combinations of restoration materials (translucent zirconia [TZI], lithium disilicate glass ceramic [IPS], polymer-infiltrated hybrid ceramic [VTE]), and customized abutment materials (PEEK and zirconia). In each model, the implants were loaded vertically (200 N) and obliquely (100 N). The stress distribution in the crown, implant, and abutments was evaluated through the von Mises stress analysis, and the stress distribution in the peripheral bone was examined through the maximum and minimum principal stress analyses.

Results

The oblique load resulted in high stress values in the implant components, restorative crown, and cortical bone. Low stress values were observed in the VTE crowns. Zirconia customized abutments exhibited higher stress values than PEEK customized abutments. The stress distributions in the implant and peripheral bone were similar in all models.

Conclusions

Changes in restoration and customized abutment material did not affect stress distribution in the implant and peripheral bone.  相似文献   

4.

Statement of problem

Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery.

Purpose

The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically.

Material and methods

A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05).

Results

The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (P<.001). The mean primary and secondary stability values for conventional dental implants were ?4.0 and ?4.9, respectively. The primary and secondary stability values for the mini-dental implants were ?0.3 and ?1.4, respectively. The Periotest values of the primary (measured immediately after implant insertion) and secondary implant stabilities (measured 6 months after implant insertion) were significantly higher for the conventional dental implants than for the mini-dental implants (P<.001).

Conclusions

Based on this 2-year clinical trial, patients receiving mini-dental implants had clinical outcomes similar to those of patients receiving conventional dental implants to support overdenture prostheses.  相似文献   

5.

Statement of problem

Implant prosthodontics provides high-quality outcomes thanks to recent technological developments and certification procedures such as International Organization for Standardization (ISO) 14801. However, these certification tests are costly, and the result is highly uncertain as the influence of design variables (materials and structure) is still unknown. The design process could be significantly improved if the influence of design parameters were identified.

Purpose

The purpose of this in vitro study was to use finite element analysis (FEA) to assess the influence of design parameters on the mechanical performance of an implant in regard to testing conditions of ISO 14801 standard.

Material and methods

An endosseous dental implant was loaded under ISO 14801 testing conditions by numerical simulation, with 4 parameters evaluated under the following conditions: conditions of the contact surface area between the implant and the loading tool, length of the fixation screw, implant embedding depth, and material used for implant stiffness. FEA was used to compare the force that needed to reach the implant’s yield and fracture strength.

Results

A dental implant’s fracture point can be increased by 41% by improving the contact surface area, by 20% depending on the type of material, by 4% depending on the length of the fixation screw, and by 1.4% by changing the implant embedding depth.

Conclusions

FEA made it possible to evaluate 4 performance parameters of a dental implant under ISO 14801 conditions. Under these conditions, the contact surface area was found to be the major parameter influencing implant performance. This observation was validated experimentally in a fatigue test under ISO 14801 conditions.  相似文献   

6.

Statement of problem

With the increased number of published systematic reviews and in view of their wide clinical applicability, these studies must be carefully assessed before professionals begin to use their recommendations in daily practice, and above all, the methodological quality of this study design must be considered. In implant dentistry, one topic that has been arousing particular interest is the immediate placement of dental implants into infected sites.

Purpose

The purpose of this systematic review was to determine the methodological quality of systematic reviews that evaluated the immediate placement of dental implants into infected sites.

Material and methods

A systematic search was performed by 2 independent reviewers of PubMed, LILACS, and ISI Web of Knowledge up to March 2016. All selected articles were published in the English language. Systematic reviews of original papers that assessed the immediate placement of dental implants into infected sites were eligible for the overview. Narrative reviews, randomized clinical trials, and case reports were excluded. Methodological quality assessment was performed using A Measurement Tool to Assess Systematic Reviews.

Results

Of the 5 selected systematic reviews, 3 were low methodological quality and 2 were assessed as moderate. None were high methodological quality. The first systematic review of the topic was published in 2010, and the most recent, published in 2015, was the only one that performed meta-analysis.

Conclusions

The systematic reviews that assessed the immediate placement of dental implants into infected sites were assessed as low or moderate methodological quality. The topic focus remains controversial because the implant survival rate, the main outcome considered for the implant placement prognosis, presents contradictory results.  相似文献   

7.

Statement of problem

Titanium implant surfaces have been modified to improve osseointegration; however, the evidence for incorporating zinc into titanium implants to improve new bone formation and osseointegration is not clear.

Purpose

The purpose of this systematic review was to assess the efficacy of treating titanium surfaces with zinc on the osseointegration of implants.

Material and methods

The focused question addressed was, “Does incorporating zinc in titanium implant surfaces influence osseointegration?” Indexed databases were searched up to January 2016 using the key words “Bone to implant contact”; “implant”; “zinc”; “osseointegration.” Letters to the editor, case reports/case series, historic reviews, and commentaries were excluded. The pattern of the review was customized to summarize the pertinent data.

Results

Ten experimental studies were included, all of which were performed in animals (5 in rabbits, 4 in rodents, and 1 in goats). The number of titanium implants placed ranged from 10 to 78. The results from all studies showed that incorporating zinc into titanium implants enhanced new bone formation and/or bone-to-implant contact around implants. One study reported that zinc enhanced the removal torque on implants.

Conclusions

The current available evidence on adding zinc to titanium implants surfaces to enhance osseointegration remains unclear. Further investigation is necessary to assess its effectiveness and safety in humans and to establish a standard methodology and ideal compound for incorporating zinc ion into titanium implant surfaces in a clinical setting.  相似文献   

8.

Statement of problem

Mandibular fixed complete-arch dental prostheses on dental implants have been benefiting patients for a long time, but problems with passive fitting between the metallic framework of the prostheses and the implants might influence its long-term success.

Purpose

The purpose of this cross-sectional study of immediately loaded mandibular fixed complete-arch dental prostheses was to evaluate the survival and success rates of prostheses, the survival rates of dental implants, the occurrence of complications in the prostheses and implants, participant satisfaction, and the association between cantilever length and prosthesis complications.

Material and methods

Data were collected from the participants’ records. The exposure variables were participant related (sex and age) and treatment related (number of implants and length of cantilever). The outcome variables were the survival and success of the prostheses and implants, complications, and participant satisfaction. The Fisher or chi-square tests was used for the association between 2 qualitative variables (α=.05).

Results

Two hundred ninety consecutive participants (1429 implants) with a mean follow-up time of 4.4 years were included. The survival rate for the prostheses was 98.6 and the success rate was 96.6%. The implant survival rate was 99.6%. Sixty-seven participants experienced a prosthetic complication, the most common being tooth fracture. Only 2.45% (n=35) of the implants were associated with screw loosening. Of the total number of participants, 86.9% were completely satisfied with their treatment. The length of the cantilever (up to 25 mm) was not associated with complications (P>.05).

Conclusions

Implant-supported mandibular fixed complete-arch dental prostheses fabricated with a passive fit technique provide successful treatment for patients with edentulism. The success and survival rates of implants and prostheses were high. Only straightforward complications were observed. Cantilever length was not associated with complications.  相似文献   

9.

Purpose

The aim of this study was to investigate how the physical variables of fibular reconstructed mandibles with dental implants affects the relative bite force in oral cancer patients.

Materials and methods

Over 7 years of follow-up, 13 oral cancer patients were enrolled who included 51 successful implants in the fibular flap. The tactile sensor analyzer evaluated the bite force. The crown-implant ratio, fibular, and rehabilitated dental length were measured using radiographic images. Linear regression was used to analyze the bite force related to the variables of the implants in the fibular reconstructed mandible.

Results

Even when the results showed no statistical significance (P > 0.05), increasing the crown-implant ratio, length of the fibular flap, and implant prosthetic reconstructed dentition had a tendency to decrease the bite force (estimate from ?0.08% to ?4.27%); there was a positive trend of occlusal force and the length of rehabilitative dentition compared with the dental antagonist (estimate = 6.95).

Conclusion

In this study, the crown-implant ratio, implant dentition, and fibular flap length revealed no significant impact on the bite force or implant success in oral cancer patients; however, a trend to weaken the bite force was suggested once the numerical values of these variables increased.  相似文献   

10.

Statement of problem

Narrow diameter implants were developed to allow placement in narrow alveolar ridges. Clinicians may have concerns about the durability and function of such implants.

Purpose

The purpose of this finite element study was to compare the stress values occurring on the implant and at the implant bone interface after the application of the static and dynamic forces on narrow diameter, titanium and titanium-zirconia implants in the maxillary and mandibular second premolar region.

Material and methods

Titanium (Ti) and titanium-zirconium (Ti-Zr) narrow diameter implants (3.3 mm in diameter, 10 mm in length) were simulated in the maxillary and mandibular second premolar region, and metal-ceramic crown restorations were designed. Forces of 100 N were applied to crowns in a vertical and oblique (45-degree angle to the long axis) direction. Maximum and minimum principal stresses in the cortical and trabecular bone and the von Mises stresses and fatigue strength of the implants were evaluated with 3-dimensional finite element analysis.

Results

In vertical and oblique static loading, Ti and Ti-Zr implants showed similar stress distribution within the same jaw models. However, the von Mises stresses in Ti-Zr implants were slightly higher than for Ti implants in all models. In oblique static and dynamic loading, all stresses were found higher than vertical loading, and fatigue failure results were found to be more critical than vertical forces.

Conclusions

Based on a numerical simulation, Ti and Ti-Zr alloys can be used successfully as narrow diameter implants in the second premolar area.  相似文献   

11.

Statement of problem

The success of implants for bone-anchored hearing aids (BAHA) relies on proper osseointegration at the bone-implant interface. Clinical evaluation of implant stability is important in prescribing loading, identifying the risk of failure, and monitoring the long-term health of the implant.

Purpose

The purpose of this in vitro study was to evaluate 2 measurement systems for BAHA implant stability: the most commonly used, Osstell implant stability quotient (ISQ), and a newly developed advance system for implant stability testing (ASIST).

Material and methods

BAHA implants (Oticon Medical Ponto and Cochlear BAHA Connect systems) were installed in plastic materials with adhesive to simulate implants integrated in bone with varying levels of interface stiffness. Different lengths of BAHA abutments were used with each implant specimen, and stability measurements were obtained with both the Osstell ISQ and the ASIST systems. The measurement systems were evaluated in terms of sensitivity to differences in interface stiffness and the effect of abutment length on the stability measurement. Repeated measures ANOVA followed by post hoc t tests were used for the comparisons with a Bonferroni adjusted alpha value of .05/15 = .003 to control for potential type 1 errors.

Results

Changing the abutment length of a single implant installation had minimal effect on the ASIST stability coefficient, whereas large variations were observed in the Osstell implant stability quotient (ISQ). The Osstell showed a clear relationship of decreasing ISQ with increasing abutment length for both the Oticon Medical and the Cochlear implant systems. Both the ASIST and the Osstell were found to be sensitive to changes in interface properties, with the ASIST being more sensitive to these changes.

Conclusions

The ASIST system is more sensitive to changes in interface properties and shows smaller variation because of changes in abutment length than the Osstell ISQ system.  相似文献   

12.

Purpose

The aim of this study was to describe the surgical technique of immediate dental implant placement in calvarial grafts for augmentation of the severely resorbed maxilla and to assess the treatment results.

Methods

In 13 patients the maxilla was augmented with calvarial bone followed by simultaneous dental implant placement (total: 68 implants). In the frontal “knife edge” region, implants were inserted in the buccal plated area. In the maxillary sinus area, implants were inserted into alveolar bone that was plated buccally or palatally through the sinus window. After 4 months, the implants were retrieved and subsequently loaded. Per-operative and post-operative variables were scored. One bone biopsy sample was taken for histological analysis.

Results

The surgical procedure and wound healing was uneventful. During abutment connection after 4 months, all implants were fully osseointegrated with no signs of graft resorption. Radiographically, the mean (±SD) peri-implant bone loss after 1 year of functional loading was 0.23 ± 0.44 mm. No implants were lost. Histological examination revealed vital calvarial and maxillary bone with active remodeling.

Conclusion

Immediate dental implant placement in calvarial bone grafts to rehabilitate severely resorbed maxilla is technically feasible and seems to have a high success rate.  相似文献   

13.

Statement of problem

Whether microthreads in the crestal portion can reduce the amount of marginal bone loss (MBL) around implants has not yet been determined.

Purpose

The purpose of this systematic review was to investigate the marginal bone loss around dental implants with and without microthreads in the neck.

Material and methods

This review was based on the PRISMA guidelines. An electronic search with no restrictions on language was performed from inception to August 19, 2015, in PubMed, Cochrane Central Register of Controlled Trials, EMBASE, Web of Sciences, and AMED (Ovid) databases. A manual search was also performed. Randomized clinical trials (RCTs) that compared the MBL between implants with and without microthreads in the neck were included. Qualitative synthesis and meta-analysis were performed. MBL was measured by using the mean difference (MD). Review Manager v5.3 software was used for meta-analysis (α=.05).

Results

Five articles were included in the qualitative synthesis, and 3 articles were included in the meta-analysis. Four studies found that a microthread design can significantly reduce MBL under functional loading, whereas 1 study found no signi?cant difference. The homogeneity test of meta-analysis confirmed acceptable heterogeneity among the 3 studies (I2=0.49). A random-effects model was used. The result shows that MBL around implants with microthread design can be reduced signi?cantly (P=.030; MD: ?0.09; CI: ?0.18 to ?0.01).

Conclusions

Meta-analysis showed that microthread design in the implant neck can reduce the amount of MBL; however, RCTs included in the review were few and the difference was small. In clinical practice, an implant with a roughened surface and microthreaded neck could be selected to maintain bone level.  相似文献   

14.

Purpose

The aim of this study was to evaluate skull replacement options after decompressive craniectomy by systematically investigating which combination of geometrical properties and material selection would result in a mechanical response comparable in stiffness to that of native skull bone and a strength as high or higher than the same.

Materials and methods

The study was conducted using a Finite Element Model of the top part of a human skull. Native skull bone, autografts and commercial implants made of PEEK, solid titanium, two titanium meshes and a titanium-ceramic composite were modeled under a set load to evaluate deformation and maximum stress.

Results

The computational result showed a large variation of the strength and effective stiffness of the autografts and implants. The stiffness of native bone varied by a factor of 20 and the strength by a factor of eight. The implants span the entire span of the native skull, both in stiffness and strength.

Conclusion

All the investigated implant materials had a potential for having the same effective stiffness as the native skull bone. All the materials also had the potential to be as strong as the native bone. To match inherent properties, the best choice of material and thickness is thus patient specific, depending on the quality of the patient's native bone.  相似文献   

15.

Statement of problem

Little information is available on the effect of drilling speed on surrounding bone during the removal of an abutment screw fragment.

Purpose

The purpose of this in vitro study was to compare, in vitro, the peak temperature increase during the removal of fractured abutment screws from implants placed in a porcine mandible, using drilling speeds of 600 or 2000 rpm.

Material and methods

Twenty 4.3×13-mm dental implants were placed in 10 dissected porcine mandibles: 2 implants per mandible, 1 on each side. Localized defects were created in 20 surface-treated abutment screws, which were then tightened into each implant until a reproducible fracture occurred in each screw. The fractured screws were removed with a handpiece removal kit and irrigated with room-temperature water at either 600 or 2000 rpm. The temperature rise at the implant surface was measured at 3 levels with 3 type-K thermocouples. Repeated measure ANOVA was performed with the Tukey-Kramer post hoc test for mean pair-wise comparisons (α=.05 for all tests).

Results

Mean peak temperatures were significantly higher at 2000 rpm than at 600 rpm in the mid-body (P<.001) and crestal (P=.003) regions but not in the apical (P=.225) implant locations. No significant differences in mean peak temperatures were found among the 3 locations using 600 rpm (P=.179). In the 2000-rpm group, mean peak temperature in the mid-body area was consistently higher than that in the apical (P<.001) area, and more instances of temperature rise above 56°C and 60°C were observed. In 1 implant from this group, the estimated peak temperature exceeded the bone damage threshold value (50°C for 30 seconds).

Conclusions

A drilling speed of 2000 rpm during the removal of abutment screw fragments caused overheating of the outer surface of the implant which may damage the surrounding bone; a speed of 600 rpm appears to be safe.  相似文献   

16.

Statement of problem

The rehabilitation of patients after a maxillectomy involves the use of an obturator to seal oral-nasal-sinus communication and to facilitate mastication, swallowing, and speech.

Purpose

The purpose of this in vitro study was to evaluate different attachment systems used for implant-retained obturators at dissipation loads and under shear forces.

Material and methods

Photoelastic models were fabricated with 3 external hexagon implants at the incisor, canine, and first molar regions. Subsequently, overdentures were made, and metal hooks were placed at the incisor and first molar regions to displace the prostheses in the vertical, anterior, and posterior directions, with a constant speed of 50 mm/min. A photoelastic model with an O-ring or bar-clip system was placed in a circular polariscope, and tested with a universal testing machine. The images were recorded and high-intensity fringes were counted using software. For strain gauge analysis, each strain gauge was placed horizontally at the mesial and distal sides of the implants. The registered strains were submitted to 2-way ANOVA (α=.05).

Results

The O-ring showed the lowest number of high-intensity fringes in photoelastic imaging, while the strain gauge analysis showed the lowest stress values in the bar-clip group (P=.007).

Conclusions

The stress around titanium implant necks was more damaging to surrounding bone, while the bar-clip attachment system had a better biomechanical performance. The bar-clip presented the lowest strain values around the dental implants and few high-intensity fringes.  相似文献   

17.

Background

Facial transplantation (FT) is a challenging reconstructive endeavor that requires the expertise of a multidisciplinary team. The specific role of maxillofacial prosthodontists has not yet been reported in detail.

Methods

This review considers the contributions of prosthodontists throughout the FT process, from patient selection and dental evaluation to long-term dental rehabilitation of the transplant patient postoperatively. Moreover, considerations of dental management are evaluated.

Results

In the almost 40 FT reported in the literature, the most consistently documented contribution by prosthodontists is the fabrication of a donor mask to maintain donor integrity. Though infrequently reported, prosthodontists have the potential to plan and perform a variety of dental procedures and follow-up plans.

Conclusions

When applicable, facial transplant teams are tasked with providing optimal stomatognathic function and dental occlusion to recipients with severe facial disfigurement. The maxillofacial prosthodontist’s contribution is crucial to the long-term dental restoration of the edentulous facial transplant candidate, in addition to the fabrication of the donor mask which fulfills the team’s ethical responsibilities.

Practical Implications

Maxillofacial prosthodontists play a pivotal role in facial transplantation, particularly when jaw segments are intended for transplantation.  相似文献   

18.

Objective

This study compared stability, removal torque, bone implant contact (BIC) and area (BA) of implants installed simultaneously with onlay autografts or allografts in rabbits' tibias.

Material and methods

Total of 18 rabbits were used in this study. Fresh frozen allografts were obtained from six animals at T(-6). Two implants with autogenous grafts (Group 1) or allografts (Group 2) were simultaneously inserted into both sides of the tibiae in a vertical periimplant defect model at T0. The resonance frequency (ISQ) was measured in implant proximal epiphysis on the day of installation of T0 and T18 (18 weeks post-surgery). At T18 the removal torque was assessed at the distal implants, the implants' proximal epiphysis and surrounding bone were harvested to perform histomorphometric analysis. The BIC and BA within the limits of the implants threads were evaluated.

Results

The ISQ revealed a statistically significant difference between T0 and T18 in each group (p = 0.024, p = 0.003). The removal torque indicates that there was no significant difference between the two groups (p = 0.47). No significant differences were observed between the groups regarding both BIC (p = 0.3713) and the BA (p = 0.3883).

Conclusion

Both grafts and implants demonstrated the same stability, torque removal and the BIC and BA.  相似文献   

19.

Statement of problem

Whether the implant abutment in implant-assisted removable partial dentures (IARPDs) functions as a natural removable partial denture (RPD) tooth abutment is unknown.

Purpose

The purpose of this 3-dimensional finite element study was to analyze the biomechanical behavior of implant crown, bone, RPD, and IARPD.

Material and methods

Finite element models of the partial maxilla, teeth, and prostheses were generated on the basis of a patient’s computed tomographic data. The teeth, surveyed crowns, and RPDs were created in the model. With the generated components, four 3-dimensional finite element models of the partial maxilla were constructed: tooth-supported RPD (TB), implant-supported RPD (IB), tooth-tissue-supported RPD (TT), and implant-tissue-supported RPD (IT) models. Oblique loading of 300 N was applied on the crowns and denture teeth. The von Mises stress and displacement of the denture abutment tooth and implant system were identified.

Results

The highest von Mises stress values of both IARPDs occurred on the implants, while those of both natural tooth RPDs occurred on the frameworks of the RPDs. The highest von Mises stress of model IT was about twice that of model IB, while the value of model TT was similar to that of model TB. The maximum displacement was greater in models TB and TT than in models IB and IT. Among the 4 models, the highest maximum displacement value was observed in the model TT and the lowest value was in the model IB.

Conclusions

Finite element analysis revealed that the stress distribution pattern of the IARPDs was different from that of the natural tooth RPDs and the stress distribution of implant-supported RPD was different from that of implant-tissue-supported RPD. When implants are used for RPD abutments, more consideration concerning the RPD design and the number or location of the implant is necessary.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号