首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Jun I  Choi YJ  Kim EK  Seo KY  Kim TI 《Eye (London, England)》2012,26(9):1243-1248

Purpose

To demonstrate the results of the ray tracing-type aberrometer in measuring spherical aberration (SA) in pseudophakic eyes with monofocal intraocular lens (IOL), aspheric monofocal IOL, or aspheric diffractive multifocal IOL.

Methods

Total, corneal, and internal SA were measured using iTrace at a 6-mm pupil size in 27 eyes of 27 patients implanted with a monofocal spherical IOL (group 1: Natural, SN60AT), 30 eyes of 30 patients implanted with a monofocal aspheric IOL (group 2: IQ, SN60WF), and 30 eyes of 30 patients implanted with a multifocal aspheric IOL (group 3: ReSTOR, SN6AD1) at 3 months after cataract surgery. We compared the internal SAs of these IOLs in pupil sizes of 3, 4, 5, and 6 mm.

Results

There were no demographic statistically significant differences among the groups. The internal SA of group 1 had a positive value. The internal SA of group 2 was −0.175±0.135 μm in 5-mm pupils and −0.227±0.253 μm in 6-mm pupils. The internal SA of group 3 was −0.072±0.128 μm in 5-mm pupils and −0.173±0.231 μm in 6-mm pupils.

Conclusion

Measuring internal SA with iTrace yields relatively accurate results in all types of IOLs with adequate pupil sizes.  相似文献   

2.

Purpose

To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry.

Methods

For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients were categorized into three groups according to the type of implanted IOLs used. IOLs were selected randomly among two types of yellow IOLs (Acrysof SN60WF IOL, Hoya YA60BBR IOL) and a clear IOL was used as a control. A FDT Humphrey matrix was performed 2 months after the surgery. The mean deviation (MD) and pattern standard deviation (PSD) among these three groups was analyzed using Mann-Whitney U-test.

Results

Two months after the procedure, there was no significant difference between each of the three groups: the clear IOL and Hoya YA60BBR IOL (MD, p = 0.21; PSD, p = 0.27), the clear IOL and Alcon SN60WF IOL (MD, p = 0.11; PSD, p = 0.22), and the Hoya YA60BBR IOL and Alcon SN60WF IOL (MD, p = 0.33; PSD, p = 0.56).

Conclusions

When interpreting the result of the FDT after cataract surgery, the color and type of IOLs used should not be considered.  相似文献   

3.

Purpose

This study was conducted to compare post-operative astigmatic outcomes of two groups, with-the-rule (WTR) and against-the-rule (ATR) astigmatism patients, according to the haptic axis of intraocular lenses (IOLs) inserted in cataract surgery.

Methods

Seventy-two eyes with WTR astigmatism and 79 eyes with ATR astigmatism had cataract surgery through a clear corneal temporal incision. These two groups of eyes were then each divided into 2 groups based on whether the haptic axis of the inserted IOL was at 180° or 90°. For ATR patients, the outcomes were analyzed according to the three types of IOLs.

Results

There was no difference in corneal astigmatism, but WTR patients with a 180° haptic axis of the inserted IOL and ATR patients with a 90° hepatic axis of the inserted IOL had a significant decrease in postoperative refractive astigmatism (p < 0.05). The changes in ATR astigmatism according to the IOL type were more effective in single-piece acrylic IOLs than in the three-piece polymethylmethacrylate haptic IOL group.

Conclusions

Insertion of the IOL at the 180° haptic axis in WTR patients and at 90° in ATR patients during cataract surgery may have an effect in reducing pre-existing astigmatism. This observed effect was not consistent among the different types of IOLs.  相似文献   

4.

Purpose

To compare the degree of tilt and decentration of an intraocular lens (IOL), refractive status, and prediction error between eyes that underwent trans-scleral suturing of the IOL within the capsular bag (in-the-bag scleral suturing) and eyes that underwent scleral suturing outside of the bag (out-of-the-bag scleral suturing) because of severe zonular dehiscence.

Patients and methods

Thirty eyes that underwent in-the-bag scleral suturing of an IOL and 38 eyes that underwent out-of-the-bag scleral suturing were recruited sequentially. The tilt and decentration of the IOL, anterior chamber depth, manifest refractive spherical equivalent (MRSE), prediction error, and incidence of complications were examined.

Results

The mean tilt angle and the decentration length of the IOL of the in-the-bag suturing group were significantly less than those of the out-of-the-bag suturing group (P=0.0003 in tilt and P=0.0391 in decentration), although the anterior chamber depth was similar. The mean MRSE and prediction error of the in-the-bag suturing group were less than those of the out-of-the-bag suturing group (P=0.0006 in MRSE and P=0.0034 in error). The incidence of vitreous loss was less in the in-the-bag suturing group than in the out-of-the-bag suturing group (20% vs63.2%, P=0.0009).

Conclusions

The tilt and decentration of the IOL after in-the-bag scleral suturing are significantly less than those after out-of-the-bag scleral suturing, which may lead to less MRSE and less prediction error. As the incidence of vitreous loss is less after in-the-bag scleral suturing, in-the-bag suturing is advantageous for eyes of younger patients and of less complicated cases.  相似文献   

5.

Purpose

To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL).

Method

Case report and literature review.

Results

Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC) are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications.

Conclusions

ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.Key words: Toric intraocular lens, Rotation, Reverse optic capture  相似文献   

6.

Purpose

To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL).

Patients and methods

Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student''s t-test.

Results

Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration.

Conclusion

The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration.  相似文献   

7.

Purpose

To evaluate the safety and visual outcomes of two phakic intraocular lenses (IOLs) for correction of high myopia: Artisan and Visian ICL (ICL).

Patients and methods

In this retrospective study, a phakic IOL was implanted in 68 highly myopic eyes of 34 patients; 42 eyes received an Artisan IOL, and 26 eyes received ICL IOL.

Results

All patients completed a 1-year follow-up. The mean preoperative spherical equivalent (SEQ) was −12.89±3.78, and −12.44±4.15 diopters (D) for Artisan and ICL (P=0.078), respectively. The mean postoperative (1-year) uncorrected distance visual acuity was 0.39±0.13 and 0.41±0.15 logMAR for Artisan and ICL, respectively (P=0.268). The mean postoperative (1-year) corrected distance visual acuity was 0.36±0.12 and 0.31±0.12 logMAR for Artisan and ICL, respectively (P=0.128). The mean postoperative SEQ was −0.86±0.5 and −0.63±0.38 D for Artisan and ICL, respectively (P=0.67). Intraocular pressure change at 1 year was 0.64±2.7 and 1.88±0.6 mm Hg for Artisan and ICL, respectively (P=0.77).

Conclusion

Artisan and ICL showed equal and comparable safety, predictability, and efficacy.  相似文献   

8.

Purpose

We report a novel technique characterized by sutureless scleral fixation of three-pieces foldable intraocular lens (IOL) using 25-gauge transconjunctival sutureless vitrectomy (TSV) trocars in patients with insufficient posterior capsule support.

Materials and Methods

We performed this technique on the eight eyes of the seven patients. The scleral tunnels (STs) are prepared by insertion of the 25-gauge TSV microcannulas using the trocars, and anterior vitrectomy is performed through the clear corneal paracentesis with the aid of anterior chamber maintainer (ACM). Finally, the three-piece foldable IOL haptics are incarcerated into the prepared STs.

Results

The patients were followed up 5–8 months. None of the patients had complications such as postoperative endophthalmitis, glaucoma, IOL tilt or decentralization, and retinal detachment. Injection of a foldable IOL through a clear corneal small incision also contributes the less surgical-induced astigmatism.

Conclusion

The presented novel sutureless scleral IOL fixation technique may provide minimal trauma to the surrounding tissues, good IOL stabilization decreasing the incidence of IOL tilt along with shorter operation time, and postoperative quiet eye.  相似文献   

9.
BACKGROUND/AIMS: Interlenticular opacification (ILO) is a recognised complication of piggyback intraocular lenses (IOLs). The aetiology, histopathology, and treatment are not clearly defined, however. METHODS: Two pairs of AcrySof IOLs were explanted from a patient with bilateral ILO. The explantation technique and surgical challenges of IOL exchanges are described. The explanted IOL complexes and a sample of the anterior capsule were examined by phase, polarising, and immunofluorescence microscopy. RESULTS: A 50 year old man developed ILO bilaterally after piggyback AcrySof IOL implantation. A central contact zone was surrounded by a homogeneous paracentral opacity possibly consisting of extracellular matrix previously laid down by proliferating lens epithelial cells (LECs). These opacities were in turn surrounded by interlenticular Elschnig pearl-type opacities contiguous with the same material filling the periphery of the capsular bag. The IOL complexes were very adherent to the capsular bag and they had to be separated with the help of high viscosity viscoelastic before a single one piece PMMA IOL implantation via large limbal incisions. The sample of anterior capsule showed a ridge configuration from the piling of LECs in the site of apposition with the anterior capsule and cells showing different characteristics on either side of the ridge. CONCLUSION: Cellular proliferation, deposition of ECM from proliferating LECs, and capsular changes induced by cell metaplasia may lead to ILO formation in piggyback AcrySof IOLs. Careful separation of the AcrySof IOL complex from the capsule, meticulous clean up of the proliferating material, and implantation of single or dual in the bag PMMA IOLs through a large incision with capsulorrhexis enlargement may help in the prevention of recurrence of interface opacification.  相似文献   

10.

Purpose

To assess the refractive change and prediction error after temporary intraocular lens (IOL) removal in temporary polypseudophakic eyes using IOL power calculation formulas and Gills'' formula.

Methods

Four consecutive patients (7 eyes) who underwent temporary IOL explantation were enrolled. Postoperative refractions calculated using IOL power calculation formulas (SRK-II, SRK-T, Hoffer-Q, Holladay, and the modified Gills'' formula for residual myopia and residual hyperopia) were compared to the manifest spherical equivalents checked at 1 month postoperatively.

Results

The mean ages of temporary piggyback IOL implantation and IOL removal were 6.71 ± 3.68 months (range, 3 to 12 months) and 51.14 ± 18.38 months (range, 29 to 74 months), respectively. The average refractive error was -13.11 ± 3.10 diopters (D) just before IOL removal, and improved to -1.99 ± 1.04 D after surgery. SRK-T showed the best prediction error of 1.17 ± 1.00 D. The modified Gills'' formula for myopia yielded a relatively good result of 1.47 ± 1.27 D, with only the variable being axial length.

Conclusions

Formulas to predict refractive change after temporary IOL removal in pediatric polypseudophakia were not as accurate as those used for single IOL implantation in adult eyes. Nonetheless, this study will be helpful in predicting postoperative refraction after temporary IOL removal.  相似文献   

11.

Background

To report on five patients with decreased visual acuity due to glistening and severe sub-surface nano-glistening (SSNG) formation within their intraocular lenses (IOLs).

Design

Case reports and analysis of extracted IOLs.

Participants and samples

We report improved visual acuity when IOLs with severe glistening and SSNG were exchanged for clear IOLs in five patients.

Methods

Case reports.

Main outcome measures

The main outcome measure was visual acuity. The secondary outcome measure was light transmission. Explanted IOLs were subjected to investigation. Pre- and postoperative slit lamp images of the anterior eye and microscopic images of the extracted IOLs were taken and compared. Light transmission of the IOL was measured using a double beam type spectrophotometer. An integrated value of the percentage light transmittance in the visible light spectrum was calculated.

Results

We report on five patients whose visual acuity improved when IOLs were exchanged because of severe glistening and SSNG. All of the affected IOLs were MA60BM (Alcon, Forth Wroth Texas, USA) and the original implantation had occurred over a range of 6–15 years prior to the IOL exchange. Light transmission was decreased in all affected lenses compared to a similar control IOL.

Conclusions

Although only a few reports of cases in which glistening and SSNG have progressed to the level of decreased visual function have been published, the likelihood is that this phenomena will increase as the severity and incidence of these inclusions have been shown to increase with time. Appropriate evaluations of visual function in such patients are needed and consideration should be given to IOL exchange in symptomatic patients.  相似文献   

12.

Purpose

To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs).

Methods

Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months.

Results

There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36).

Conclusions

The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.  相似文献   

13.

Purpose:

To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children.

Setting:

Tertiary care setting

Materials and Methods:

We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO).

Results:

Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA) in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL.

Conclusions:

Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation  相似文献   

14.

Purpose

To report outcomes of deep sclerectomy (DS) with intraoperative mitomycin C (MMC) application in eyes with previous failed glaucoma surgery (GS) and/or cataract extraction (CE).

Patients and methods

Single-surgeon case series of 82 eyes of 82 patients undergoing DS with MMC. The patients had previous CE with IOL and/or conjunctival GS and treated intraocular pressure (IOP) >18 mm Hg. MMC (0.2 mg/ml) was applied for 2–3 min before scleral flap dissection. Complete success was defined as IOP between 6 and 21 mm Hg or a reduction of 20% from baseline without medications. Reoperation for glaucoma or related complications, or loss of light perception vision was considered as failure.

Results

Mean follow-up was 57.7±22.4 months with 78% of patients completing the 3-year follow-up. Mean IOP decreased from 24.0 mm Hg (22.3–25.6, 95% confidence intervals) to 13.4 mm Hg (12.0–14.2) at 3 years after surgery (P<0.001). There was a significant decrease in the number of glaucoma medications from 2.0±1 preoperatively, to 0.3±0.7, 3 years after surgery. Kaplan–Meier cumulative success rates were 85.6% at 1 year, 80.0% at 2 years, and 76% at 3 years. At 3 years, IOP was maintained <19 and 15 mm Hg in 83 and 70% of eyes, respectively. Fourteen eyes (17.1%) had complications. Delayed hypotony (IOP <6 mm Hg) was the commonest complication in five eyes (6.1%).

Conclusion

DS with MMC appears to be a safe and effective surgical procedure for eyes with previous intraocular surgery.  相似文献   

15.

Background

We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA) with overlaying Acrysof EXpand® minus piggyback lens (Alcon).

Methods

The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral placement of the ReSTOR multifocal lens. The necessary intraocular lens (IOL) power was +3.5 in the right eye and +4.0 in the left eye, though the range of commercially available ReSTOR lenses is +6.0 to +34.0 D. In order to achieve emmetropia in this case of high myopia, it was determined that an EXpand minus piggyback lens would be necessary.

Results

Implantation of the ReSTOR lens with overlaying EXpand minus piggyback lens was performed successfully and without complication. At 5 months postoperatively, the patient had 20/20 uncorrected visual acuity in both eyes. She reported a high level of satisfaction and was able to return to her daily activities including reading and driving without spectacles.

Conclusion

We report successful primary implantation of AcrySof EXpand minus piggyback lenses overlying the AcrySof IQ ReSTOR lens in a patient with high myopia. Long-term follow-up and further evaluation is necessary to establish piggyback IOL implantation with multifocal IOL as an accepted treatment for high myopia with presbyopia.Key words: Multifocal lens, Piggyback lens, High myopia  相似文献   

16.

Purpose:

To study the outcome of in-the-bag implanted square-edge polymethyl methacrylate (PMMA) intraocular lenses (IOL) with and without primary posterior capsulotomy in pediatric traumatic cataract.

Materials and Methods:

The study was undertaken in a tertiary care center. Thirty eyes of 30 children ranging in age from 4 to 16 years with traumatic cataract which underwent cataract extraction with capsular bag implantation of IOL were prospectively evaluated. Group A included 15 eyes of 15 children where primary posterior capsulotomy (PPC) and anterior vitrectomy with capsular bag implantation of square-edge PMMA IOL (Aurolab SQ3602, Madurai, Tamil Nadu, India) was performed. Group B comprised 15 eyes of 15 children in which the posterior capsule was left intact. Postoperative visual acuity, visual axis opacification (VAO) and possible complications were analyzed.

Results:

Best corrected visual acuity (BCVA) of 20/40 or better was achieved in 12 of 15 eyes in both groups. Amblyopia was the cause of no improvement in visual acuity in the remaining eyes. Visual axis opacification was significantly high in Group B as compared to Group A (P=0.001). Postoperative fibrinous uveitis occurred in most of the eyes in both groups. Pupillary capture was observed in one eye in each group.

Conclusion:

Primary posterior capsulotomy and anterior vitrectomy with capsular bag implantation of square-edge PMMA significantly helps to maintain a clear visual axis in children with traumatic cataract.  相似文献   

17.

Purpose

To analyze the anatomical and functional outcome of glued intra ocular lens (IOL) implantation technique and its modifications.

Design

Retrospective observational case series.

Methods

This is a retrospective analysis of the patients who underwent glued intra ocular lens implantation from December 2007 to August 2010. Post operative uncorrected vision, best corrected visual acuity (BCVA), intra ocular pressure, IOL position, endothelial cells and anterior chamber reaction at their last follow up are analyzed from their concerned case sheets documentation. Subjective changes are analyzed via individual questionnaire. Immediate and late postoperative complications are also evaluated. Surgical modifications and the difference in the operated eyes are analyzed.

Results

Total 210 glued IOL eyes have been reviewed. Out of this 210, there are 152 (PMMA glued IOL), 21 (three piece foldable IOL), 5 (multifocal foldable IOL), 12 (pediatric glued IOL), 5 (20G sutureless vitrectomy), 2 (glued iris prosthesis) and 3 (transposition of posterior chamber IOL into anterior chamber). In combined surgeries there are, 5 (optical penetrating keratoplasty), 2 (descemet’s stripping endothelial keratoplasty) and 3 (iridoplasty). The modifications in glued IOL are handshake technique, injectable or foldable glued IOL, Multifocal glued IOL and intraoperative 23/25G trocar cannula infusion. Decentration (1.97%), macular edema (1.97%) and optic capture (2.63%) are the post operative complications encountered in rigid glued IOL. Good patient satisfaction is seen in the eyes with IOL repositioning, IOL exchange and multifocal glued IOL. There is significant improvement in BCVA in PMMA IOL (p = 1.35 × 10−5) and foldable IOL (p = 0.000).

Conclusion

Glued IOL seems to be a good alternative in IOL implantation in eyes with deficient capsules. The modifications in the existing technique decrease the learning time and risk for complications.  相似文献   

18.
AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08±2.44) diopters (D) and cylinder was (-1.35±0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up. RESULTS: After 1 year of follow-up, no eyes lost≥1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27±3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed. CONCLUSION: After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.  相似文献   

19.

Purpose

To assess the agreement of the optical low-coherence reflectometry (OLCR) device LENSTAR LS900 with partial coherence interferometry (PCI) device IOLMaster and applanation and immersion ultrasound biometry.

Methods

We conducted the study at the Ophthalmology Clinic, University of Malaya Medical Center, Malaysia. Phakic eyes of 76 consecutive cataract patients were measured using four different methods: IOLMaster, LENSTAR and A-scan applanation and immersion ultrasound biometry. We assessed the method agreement in the LENSTAR-IOLMaster, LENSTAR-applanation, and LENSTAR-immersion comparisons for axial length (AL) and intraocular lens (IOL) power using Bland–Altman plots. For average K, we compared LENSTAR with IOLMaster and the TOPCON KR-8100 autorefractor-keratometer. SRK/T formula was used to compute IOL power, with emmetropia as the target refractive outcome.

Results

For all the variables studied, LENSTAR agreement with IOLMaster is strongest, followed by those with immersion and applanation. For the LENSTAR-IOLMaster comparison, the estimated proportion of differences falling within 0.33 mm from zero AL and within 1D from zero IOL power is 100%. The estimated proportion of differences falling within 0.5 D from zero average K is almost 100% in the LENSTAR-IOLMaster comparison but 88% in the LENSTAR-TOPCON comparison. The proportion of differences falling within 0.10 mm (AL) and within 1D (IOL power) in the LENSTAR-IOLMaster comparison has practically significant discrepancy with that of LENSTAR-applanation and LENSTAR-immersion comparisons.

Conclusions

In phakic eyes of cataract patients, measurements of AL, average K, and IOL power calculated using the SRK/T formula from LENSTAR are biometrically equivalent to those from IOLMaster, but not with those from applanation and immersion ultrasound biometry.  相似文献   

20.

Purpose

To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients.

Methods

This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3±5.0 months) follow-up were evaluated.

Results

At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28±0.38 diopter (D) from -1.28±0.48 D. The mean rotation of the toric IOL was 3.45±3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees.

Conclusions

Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号