共查询到20条相似文献,搜索用时 15 毫秒
1.
Stéphane Bancelin Charles-André Couture Katherine Légaré Maxime Pinsard Maxime Rivard Cameron Brown Fran?ois Légaré 《Biomedical optics express》2016,7(2):399-408
We report the implementation of fast Interferometric Second Harmonic Generation (I-SHG) microscopy to study the polarity of non-centrosymmetric structures in biological tissues. Using a sample quartz plate, we calibrate the spatially varying phase shift introduced by the laser scanning system. Compensating this phase shift allows us to retrieve the correct phase distribution in periodically poled lithium niobate, used as a model sample. Finally, we used fast interferometric second harmonic generation microscopy to acquire phase images in tendon. Our results show that the method exposed here, using a laser scanning system, allows to recover the polarity of collagen fibrils, similarly to standard I-SHG (using a sample scanning system), but with an imaging time about 40 times shorter.OCIS codes: (180.4315) Nonlinear microscopy, (190.2620) Harmonic generation and mixing, (170.6935) Tissue characterization, (190.4180) Multiphoton processes, (190.4710) Optical nonlinearities in organic materials 相似文献
2.
We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures such as actin, myosin, acto-myosin, and the intact T-tubular system as it emanates from the sarcolemma. Owing to sub-micron spatial resolution and the high sensitivity of the CARS microscopy technique we were able to resolve individual myofibrils. In addition, key organelles such as mitochondria, cell nuclei and their structural constituents were observed revealing the entire structure of the muscle functional units. There is a noticeable difference in the CARS response of the muscle structure within actin, myosin and t-tubule areas with respect to laser polarization. We attribute this to a preferential alignment of the probed molecular bonds along certain directions. The combined CARS and SHG microscopy approach yields more extensive and complementary information and has a potential to become an indispensable method for live skeletal muscle characterization. 相似文献
3.
Kennedy Brittain MacAulay Harvey Richard Cisek Saranyan Pillai Sean D Christie Danielle Tokarz 《Biomedical optics express》2022,13(6):3593
The origin of second harmonic generation (SHG) signal in otoconia was investigated. SHG signal intensity from otoconia was compared to pure calcite crystals, given calcite is the primary component of otoconia and is known to emit surface SHG. The SHG intensity from calcite was found to be ∼41× weaker than the SHG intensity from otoconia signifying that the SHG signal from otoconia is likely generated from the organic matrix. Furthermore, the SHG intensity from otoconia increased when treated with a chelating agent known to dissolve calcite which confirms that calcite is not the source of SHG. Additionally, polarization-resolved SHG microscopy imaging revealed that the arrangement of the SHG emitters is radial and can form highly ordered domains. 相似文献
4.
Juan M. Bueno Francisco J. vila Elvira Lorenzo-Martín Patricia Gallego-Muoz M. Carmen Martínez-García 《Biomedical optics express》2021,12(2):756
The organization of the corneal stoma is modified due to different factors, including pathology, surgery or external damage. Here the changes in the organization of the corneal collagen fibers during natural healing after chemical burn are investigated using second harmonic generation (SHG) imaging. Moreover, the structure tensor (ST) was used as an objective tool for morphological analyses at different time points after burn (up to 6 months). Unlike control corneas that showed a regular distribution, the collagen pattern at 1 month of burn presented a non-organized arrangement. SHG signal levels noticeably decreased and individual fibers were hardly visible. Over time, the healing process led to a progressive re-organization of the fibers that could be quantified through the ST. At 6 months, the stroma distribution reached values similar to those of control eyes and a dominant direction of the fibers re-appeared. The present results show that SHG microscopy imaging combined with the ST method is able to objectively monitor the temporal regeneration of the corneal organization after chemical burn. Future implementations of this approach into clinically adapted devices would help to diagnose and quantify corneal changes, not only due to chemical damages, but also as a result of disease or surgical procedures. 相似文献
5.
Viet-Hoan Le Seunghun Lee Bumju Kim Yeoreum Yoon Calvin J. Yoon Wan Kyun Chung Ki Hean Kim 《Biomedical optics express》2015,6(7):2542-2551
Both polarization sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are 3D optical imaging methods providing information related to collagen in the skin. PS-OCT provides birefringence information which is due to the collagen composition of the skin. SHG microscopy visualizes collagen fibers in the skin based on their SHG property. These two modalities have been applied to the same skin pathologies associated with collagen changes, but their relationship has not been examined. In this study, we tried to find the relationship by imaging the same skin samples with both modalities. Various parts of the normal rat skin and burn damaged skin were imaged ex vivo, and their images were analyzed both qualitatively and quantitatively. PS-OCT images were analyzed to obtain tissue birefringence. SHG images were analyzed to obtain collagen orientation indices by applying 2D Fourier transform. The skin samples having higher birefringence values had higher collagen orientation indices, and a linear correlation was found between them. Burn damaged skin showed decreases in both parameters compared to the control skins. This relationship between the bulk and microscopic properties of skin may be useful for further skin studies.OCIS codes: (260.1440) Birefringence, (170.3890) Medical optics instrumentation, (180.4315) Nonlinear microscopy, (170.4500) Optical coherence tomography, (170.2655) Functional monitoring and imaging 相似文献
6.
To identify the neural constituents responsible for generating polarized light changes, we created spatially resolved movies of propagating action potentials from stimulated lobster leg nerves using both reflection and transmission imaging modalities. Changes in light polarization are associated with membrane depolarization and provide sub-millisecond temporal resolution. Typically, signals are detected using light transmitted through tissue; however, because we eventually would like to apply polarization techniques in-vivo, reflected light is required. In transmission mode, the optical signal was largest throughout the center of the nerve, suggesting that most of the optical signal arose from the inner nerve bundle. In reflection mode, polarization changes were largest near the edges, suggesting that most of the optical signal arose from the outer sheath. In support of these observations, an optical model of the tissue showed that the outer sheath is more reflective while the inner nerve bundle is more transmissive. In order to apply these techniques in-vivo, we must consider that brain tissue does not have a regular orientation of processes as in the lobster nerve. We tested the effect of randomizing cell orientation by tying the nerve in an overhand knot prior to imaging, producing polarization changes that can be imaged even without regular cell orientations. 相似文献
7.
Cheng-Kun Tsai Yu-Shing Chen Pei-Chun Wu Tsung-Yuan Hsieh Han-Wen Liu Chiou-Yueh Yeh Win-Li Lin Jean-San Chia Tzu-Ming Liu 《Biomedical optics express》2012,3(9):2234-2243
Using third harmonic generation (THG) microscopy, we demonstrate that granularity differences of leukocytes can be revealed without a label. Excited by a 1230 nm femtosecond laser, THG signals were generated at a significantly higher level in neutrophils than other mononuclear cells, whereas signals in agranular lymphocytes were one order of magnitude smaller. Interestingly, the characteristic THG features can also be observed in vivo to track the newly recruited leukocytes following lipopolysaccharide (LPS) challenge. These results suggest that label-free THG imaging may provide timely tracking of leukocyte movement without disturbing the normal cellular or physiological status.OCIS codes: (180.4315) Nonlinear microscopy, (170.1530) Cell analysis 相似文献
8.
Jun Ho Lee Seunghun Lee Calvin J. Yoon Jin Hyoung Park Hungwon Tchah Myoung Joon Kim Ki Hean Kim 《Biomedical optics express》2016,7(2):677-687
Fungal keratitis is an infection of the cornea by fungal pathogens. Diagnosis methods based on optical microscopy could be beneficial over the conventional microbiology method by allowing rapid and non-invasive examination. Reflectance confocal microscopy (RCM) and two-photon second harmonic generation microscopy (TPSHGM) have been applied to pre-clinical or clinical studies of fungal keratitis. In this report, RCM and TPSHGM were characterized and compared in the imaging of a fungal keratitis rabbit model ex vivo. Fungal infection was induced by using two strains of fungi: aspergillus fumigatus and candida albicans. The infected corneas were imaged in fresh condition by both modalities sequentially and their images were analyzed. Both RCM and TPSHGM could detect both fungal strains within the cornea based on morphology: aspergillus fumigatus had distinctive filamentous structures, and candida albicans had round structures superficially and elongated structures in the corneal stroma. These imaging results were confirmed by histology. Comparison between RCM and TPSHGM showed several characteristics. Although RCM and TPSHGM images had good correlation each other, their images were slightly different due to difference in contrast mechanism. RCM had relatively low image contrast with the infected turbid corneas due to high background signal. TPSHGM visualized cells and collagen in the cornea clearly compared to RCM, but used higher laser power to compensate low autofluorescence. Since these two modalities provide complementary information, combination of RCM and TPSHGM would be useful for fungal keratitis detection by compensating their weaknesses each other.OCIS codes: (170.0170) Medical optics and biotechnology, (170.1790) Confocal microscopy, (170.2520) Fluorescence microscopy, (170.4470) Ophthalmology 相似文献
9.
Danielle Tokarz Richard Cisek Ahmad Golaraei Sylvia L. Asa Virginijus Barzda Brian C. Wilson 《Biomedical optics express》2015,6(9):3475-3481
Changes in collagen ultrastructure between malignant and normal human thyroid tissue were investigated ex vivo using polarization second harmonic generation (SHG) microscopy. The second-order nonlinear optical susceptibility tensor component ratio and the degree of linear polarization (DOLP) of the SHG signal were measured. The ratio values are related to the collagen ultrastructure, while DOLP indicates the relative amount of coherent signal and incoherent scattering of SHG. Increase in ratio values and decrease in DOLP were observed for tumor tissue compared to normal thyroid, indicating higher ultrastructural disorder in tumor collagen.OCIS codes: (180.4315) Nonlinear microscopy, (170.3880) Medical and biological imaging, (170.4730) Optical pathology, (170.6935) Tissue characterization 相似文献
10.
Cheng-Kun Tsai Tzung-Dau Wang Jong-Wei Lin Ron-Bin Hsu Lun-Zhang Guo San-Tai Chen Tzu-Ming Liu 《Biomedical optics express》2013,4(1):178-186
Using the sectioning capability of third harmonic generation (THG) microscopy, we assessed the morphologic features of human adipocytes directly without fixation and labeling. At the plane of the largest cross-sectional area, both area-equivalent circular diameters (AECD) and perimeters of adipocytes were measured, and their statistical distributions were examined. We found, in patients with no cardiovascular risk factors, the average AECD of epicardial adipocytes were 70–90 μm with 11–17 μm standard deviations. In contrast, for patients with coronary artery disease, amounts of small-sized (AECD <40 µm) epicardial adipocytes were observed and the corresponding standard deviations of AECD were increased to 20–29 μm. Our results indicate that the THG tomography platform can be used to explore the histopathological features of adipocytes in clinical scenarios based on its superior resolution for virtual optical biopsy.OCIS codes: (170.6900) Three-dimensional microscopy, (190.1900) Diagnostic applications of nonlinear optics 相似文献
11.
Rivard M Laliberté M Bertrand-Grenier A Harnagea C Pfeffer CP Vallières M St-Pierre Y Pignolet A El Khakani MA Légaré F 《Biomedical optics express》2010,2(1):26-36
Fascia tissue is rich in collagen type I proteins and can be imaged by second harmonic generation (SHG) microscopy. While identifying the overall alignment of the collagen fibrils is evident from those images, the tridimensional structural origin for the observation of SHG signal is more complex than it apparently seems. Those images reveal that the noncentrosymmetric (piezoelectric) structures are distributed heterogeneously on spatial dimensions inferior to the resolution provided by the nonlinear optical microscope (sub-micron). Using piezoresponse force microscopy (PFM), we show that an individual collagen fibril has a noncentrosymmetric structural organization. Fibrils are found to be arranged in nano-domains where the anisotropic axis is preserved along the fibrillar axis, while across the collagen sheets, the phase of the second order nonlinear susceptibility is changing by 180 degrees between adjacent nano-domains. This complex architecture of noncentrosymmetric nano-domains governs the coherent addition of 2ω light within the focal volume and the observed features in the SHG images taken in fascia. 相似文献
12.
Maxime Rivard Mathieu Laliberté Antony Bertrand-Grenier Catalin Harnagea Christian P. Pfeffer Martin Vallières Yves St-Pierre Alain Pignolet My Ali El Khakani Fran?ois Légaré 《Biomedical optics express》2011,2(1):26-36
Fascia tissue is rich in collagen type I proteins and can be imaged by second harmonic generation (SHG) microscopy. While identifying the overall alignment of the collagen fibrils is evident from those images, the tridimensional structural origin for the observation of SHG signal is more complex than it apparently seems. Those images reveal that the noncentrosymmetric (piezoelectric) structures are distributed heterogeneously on spatial dimensions inferior to the resolution provided by the nonlinear optical microscope (sub-micron). Using piezoresponse force microscopy (PFM), we show that an individual collagen fibril has a noncentrosymmetric structural organization. Fibrils are found to be arranged in nano-domains where the anisotropic axis is preserved along the fibrillar axis, while across the collagen sheets, the phase of the second order nonlinear susceptibility is changing by 180 degrees between adjacent nano-domains. This complex architecture of noncentrosymmetric nano-domains governs the coherent addition of 2ω light within the focal volume and the observed features in the SHG images taken in fascia.OCIS codes: (180.4315) Nonlinear microscopy, (190.4160) Multiharmonic generation 相似文献
13.
Ahmad Golaraei Richard Cisek Serguei Krouglov Roya Navab Carolyn Niu Shingo Sakashita Kazuhiro Yasufuku Ming-Sound Tsao Brian C. Wilson Virginijus Barzda 《Biomedical optics express》2014,5(10):3562-3567
Polarization second harmonic microscopy was used for collagen imaging in human non-small cell lung carcinoma and normal lung tissues ex vivo and revealed significant differences in the nonlinear susceptibility component ratio, demonstrating potential use in cancer diagnosis.OCIS codes: (180.0180) Microscopy, (180.4315) Nonlinear microscopy, (190.4160) Multiharmonic generation 相似文献
14.
Lukas Kontenis Masood Samim Abiramy Karunendiran Serguei Krouglov Bryan Stewart Virginijus Barzda 《Biomedical optics express》2016,7(2):559-569
The experimental implementation of double Stokes Mueller polarimetric microscopy is presented. This technique enables a model-independent and complete polarimetric characterization of second harmonic generating samples using 36 Stokes parameter measurements at different combinations of incoming and outgoing polarizations. The degree of second harmonic polarization and the molecular nonlinear susceptibility ratio are extracted for individual focal volumes of a fruit fly larva wall muscle.OCIS codes: (180.4315) Nonlinear microscopy, (110.5405) Polarimetric imaging, (170.3880) Medical and biological imaging 相似文献
15.
Recent clinical studies on human skin indicated that in vivo multi-harmonic generation microscopy (HGM) can achieve sub-micron resolution for histopathological analysis with a high penetration depth and leave no energy or photodamages in the interacted tissues. It is thus highly desired to apply HGM for in vivo mucosa histopathological diagnosis. In this paper, the first in vivo optical virtual biopsy of human oral mucosa by using epi-HGM is demonstrated. We modified an upright microscope to rotate the angle of objective for in vivo observation. Our clinical study reveals the capability of HGM to in vivo image cell distributions in human oral mucosa, including epithelium and lamina propria with a high penetration depth greater than 280 μm and a high spatial resolution better than 500 nm. We also found that the third-harmonic-generation (THG) contrast on nucleus depends strongly on its thicknesses, in agreement with a numerical simulation. Besides, 4% acetic acid was found to be able to enhance the THG contrast of nucleus in oral mucosa, while such enhancement was found to decay due to the metabolic clearance of the contrast enhancer by the oral mucosa. Our clinical study indicated that, the combined epi-THG and epi-second-harmonic-generation (SHG) microscopy is a promising imaging tool for in vivo noninvasive optical virtual biopsy and disease diagnosis in human mucosa. 相似文献
16.
Nirmal Mazumder Jianjun Qiu Matthew R. Foreman Carlos Macías Romero Peter T?r?k Fu-Jen Kao 《Biomedical optics express》2013,4(4):538-547
We report on the measurement and analysis of the polarization state of second harmonic signals generated by starch granules, using a four-channel photon counting based Stokes-polarimeter. Various polarization parameters, such as the degree of polarization (DOP), the degree of linear polarization (DOLP), the degree of circular polarization (DOCP), and anisotropy are extracted from the 2D second harmonic Stokes images of starch granules. The concentric shell structure of a starch granule forms a natural photonic crystal structure. By integration over all the solid angle, it will allow very similar SHG quantum efficiency regardless of the angle or the states of incident polarization. Given type I phase matching and the concentric shell structure of a starch granule, one can easily infer the polarization states of the input beam from the resulting SH micrograph.OCIS codes: (180.4315) Nonlinear microscopy, (120.5410) Polarimetry, (320.0320) Ultrafast optics, (120.0120) Instrumentation, measurement, and metrology, (160.1435) Biomaterials 相似文献
17.
Uniform, porous particles of lithium niobate (LiNbO3) can be used as contrast agents in bioimaging, drug delivery carriers, nonlinear optical emitters, biosensors, photocatalysts and electrode materials in lithium-ion batteries. In this article, we introduce a hydrothermal method to prepare uniform, mesoporous LiNbO3 particles with a tunable diameter and porosity. These properties are each tuned by adjusting the reaction times of the hydrothermal process. This approach forms mesoporous LiNbO3 particles without the addition of organic additives (e.g., surfactants) or hard templates (e.g., silica). Formation of these LiNbO3 particles proceeds through an aqueous sol–gel reaction in which niobium hydroxide species are generated in situ and undergo a condensation reaction in the presence of lithium hydroxide to form a colloidal solution. A hydrothermal reaction using this solution resulted in the formation of uniform, solid, and semi-crystalline particles. A post-calcination step induces crystallinity in the product and transforms the particles into mesoporous materials composed of a rhombohedral LiNbO3 phase. An increase in reaction time results in an increase in the diameter of these particles from 580 to 1850 nm, but also decreases their porosity. These LiNbO3 particles were active towards second harmonic generation (SHG), and their SHG response resembled that of larger crystals of rhombohedral LiNbO3. This work also offers a viable strategy for manufacturing other materials (e.g., tantalates, titanates, niobates) with tunable dimensions and porosity that enable a broad range of applications in photonics, energy, and catalysis.Tunable, mesoporous lithium niobate particles with an active optical second harmonic generation (SHG) response. 相似文献
18.
With a video-rate third harmonic generation (THG) microscopy system, we imaged the micro-circulation beneath the human skin without labeling. Not only the speed of circulation but also the morpho-hydrodynamics of blood cells can be analyzed. Lacking of nuclei, red blood cells (RBCs) shows typical parachute-like and hollow-core morphology under THG microscopy. Quite different from RBCs, every now and then, round and granule rich blood cells with strong THG contrast appear in circulation. The corresponding volume densities in blood, evaluated from their frequencies of appearance and the velocity of circulation, fall within the physiological range of human white blood cell counts.OCIS codes: (170.6900) Three-dimensional microscopy, (190.1900) Diagnostic applications of nonlinear optics 相似文献
19.
Latour G Gusachenko I Kowalczuk L Lamarre I Schanne-Klein MC 《Biomedical optics express》2012,3(1):1-15
The transparency and mechanical strength of the cornea are related to the highly organized three-dimensional distribution of collagen fibrils. It is of great interest to develop specific and contrasted in vivo imaging tools to probe these collagenous structures, which is not available yet. Second Harmonic Generation (SHG) microscopy is a unique tool to reveal fibrillar collagen within unstained tissues, but backward SHG images of cornea fail to reveal any spatial features due to the nanometric diameter of stromal collagen fibrils. To overcome this limitation, we performed polarization-resolved SHG imaging, which is highly sensitive to the sub-micrometer distribution of anisotropic structures. Using advanced data processing, we successfully retrieved the orientation of the collagenous fibrils at each depth of human corneas, even in backward SHG homogenous images. Quantitative information was also obtained about the submicrometer heterogeneities of the fibrillar collagen distribution by measuring the SHG anisotropy. All these results were consistent with numerical simulation of the polarization-resolved SHG response of cornea. Finally, we performed in vivo SHG imaging of rat corneas and achieved structural imaging of corneal stroma without any labeling. Epi-detected polarization-resolved SHG imaging should extend to other organs and become a new diagnosis tool for collagen remodeling. 相似文献
20.
Tobias Ehmke Tim Heiko Nitzsche Andreas Knebl Alexander Heisterkamp 《Biomedical optics express》2014,5(7):2231-2246
We demonstrate the possibility to switch the z-polarization component of the illumination in the vicinity of the focus of high-NA objective lenses by applying radially and azimuthally polarized incident light. The influence of the field distribution on nonlinear effects was first investigated by the means of simulations. These were performed for high-NA objective lenses commonly used in nonlinear microscopy. Special attention is paid to the influence of the polarization of the incoming field. For linearly, circularly and radially polarized light a considerable polarization component in z-direction is generated by high NA focusing. Azimuthal polarization is an exceptional case: even for strong focusing no z-component arises. Furthermore, the influence of the input polarization on the intensity contributing to the nonlinear signal generation was computed. No distinct difference between comparable input polarization states was found for chosen thresholds of nonlinear signal generation. Differences in signal generation for radially and azimuthally polarized vortex beams were experimentally evaluated in native collagen tissue (porcine cornea). The findings are in good agreement with the theoretical predictions and display the possibility to probe the molecular orientation along the optical axis of samples with known nonlinear properties. The combination of simulations regarding the nonlinear response of materials and experiments with different sample orientations and present or non present z-polarization could help to increase the understanding of nonlinear signal formation in yet unstudied materials.OCIS codes: (000.3860) Mathematical methods in physics, (180.4315) Nonlinear microscopy, (190.0190) Nonlinear optics, (190.2620) Harmonic generation and mixing, (190.4975) Parametric processes, (260.5430) Polarization 相似文献