首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 906 毫秒
1.
We studied 23 patients with cirrhosis who had undergone retroperitoneal distal splenorenal shunt without portal-azygos disconnection more than 2 yr earlier. We investigated the suitability of the Doppler technique (ultrasound + Doppler) to assess the patency and blood flow direction through the portal vein and the distal splenorenal shunt and its correlation with the continuous thermal dilution technique. The study also assessed the influence of the distal splenorenal shunt and time after surgery on portal perfusion and liver function. Ultrasound + Doppler distal splenorenal shunt thrombosis in two patients; however, none was confirmed by continuous thermal dilution. Ultrasound + Doppler flowmetry was possible in 19 patients (83%) (mean, 1.58 +/- 0.53 L/min). Distal splenorenal shunt continuous thermal dilution measurements were performed in all patients (100%), (mean, 1.65 +/- 0.5 L/min). Good correlation was seen between them (r = 0.66). Ultrasound + Doppler of the portal vein showed a hepatopetal flow in 16 patients (69.9%). Hepatic blood flow was significantly higher in patients with hepatopetal flow (p = 0.003). Hepatic clearance and intrinsic hepatic clearance of indocyanine green were significantly lower in patients with hepatofugal flow. Patients with hepatofugal flow had a higher incidence of chronic encephalopathy. None of the patients with a follow-up of less than 4 yr exhibited hepatofugal flow, whereas 7 of the 16 patients with a longer follow-up had hepatofugal flow (43.7%). The difference was statistically significant (p = 0.04). This study suggests that ultrasound + Doppler sonography may provide useful data in the evaluation of the patency and blood flow direction through the portal vein and the distal splenorenal shunt.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Propranolol has been demonstrated to be effective in lowering portal pressure in cirrhotic patients. This effect is mediated by a reduction of splanchnic arterial inflow and a consequent decrease of portal vein and portocollateral blood flow. Although experimental studies suggest a direct effect of the drug on portocollateral circulation, little information exists about relative flow changes occurring in the portal vein and in collateral veins feeding esophageal varices. This study addressed the problem in 12 cirrhotic patients selected on the basis of feasibility of Doppler flowmetry in both the portal and left gastric veins. Caliber, flow velocity and flow volume in both vessels were measured by Doppler ultrasound before and at 60, 120 and 180 min after an oral dose of 40 mg propranolol, together with heart rate and mean arterial pressure. A significant decrease in heart rate (-17.6% +/- 1.1%, p less than 0.001) and mean arterial pressure (-10.6% +/- 0.9%, p less than 0.005) confirmed effective beta-blockade. Baseline flow velocity was significantly lower in the portal vein than in the left gastric vein (12.4 +/- 0.6 vs. 15.4 +/- 1.5 cm/sec, p less than 0.05). Maximal hemodynamic effect was reached at 120 min after administration of propranolol. The vessel caliber did not change significantly. Flow velocity fell from 12.4 +/- 0.6 to 10.4 +/- 0.7 cm/sec in the portal vein (p less than 0.05) and from 15.4 +/- 1.5 to 11.1 +/- 0.9 cm/sec in the left gastric vein (p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
In order to evaluate the behavior of the portal vein cross-sectional area during changes in portal flow, two groups of subjects were analyzed in two blinded cross-over studies using echo-Doppler flowmetry. The first group (I) consisted of 21 patients with cirrhosis and 16 controls. They received a standardized meal which is known to increase portal flow. The second group (II) consisted of 31 patients with cirrhosis who received a dose of propranolol which is known to decrease portal flow. In Group I, 30 min after the meal, the portal vein blood velocity increased by 35 +/- 6% (p less than 0.01) in cirrhotic patients and by 55 +/- 5% (p less than 0.01), in normal subjects. The portal vein cross-sectional area increased significantly in normal subjects (22 +/- 2%, p less than 0.01) but not in cirrhotic patients (4 +/- 2%, n.s.). In Group II, 2 h after propranolol, there was a significant decrease in portal blood velocity (-14 +/- 2%), whereas the portal vein cross-sectional area did not show any significant changes. These data demonstrate that, in portal hypersensitive patients, the portal area measured by echo-Doppler flowmetry can be assumed to be constant and hence its calculation to estimate changes in portal blood flow can be omitted. Therefore, the use of blood velocity alone is suggested to monitor acute changes in flow in portal hypertension using Doppler flowmetry. The elimination of the portal vein cross-sectional area measurement simplifies the quantitative calculation of portal hemodynamics and increases the reliability of the technique by avoiding a source of error.  相似文献   

4.
The effect of metoclopramide on portal blood flow, the maximal diameter of the portal vein, and some cardiovascular haemodynamic variables was studied in 10 patients with cirrhosis of the liver and portal hypertension. Portal vein haemodynamics were studied by the pulsed Doppler system. Within 15 min of intravenous administration of 20 mg metoclopramide, portal blood velocity and portal blood flow decreased significantly, from 11.2 +/- 1.1 to 10.8 +/- 1.2 cm/sec and from 769.0 +/- 87.7 to 707.9 +/- 84.2 ml/min, respectively (p less than 0.001). Within about 30 min portal blood velocity and portal blood flow returned to basal values (p greater than 0.05). The maximal diameter of the portal vein, systolic and diastolic blood pressure, and heart rate remained unchanged. These results support the hypothesis that metoclopramide, which raises lower oesophageal sphincter pressure and reduces intravariceal blood flow, significantly decreases the portal blood flow in cirrhotic patients with portal hypertension.  相似文献   

5.
Hepatic microcirculation is a main determinant of reperfusion injury and graft quality in liver transplantation. Methods available for the quantification of hepatic microcirculation are indirect, are invasive, or preclude postoperative application. The aim of this study was the validation of thermodiffusion in a new modification allowing long-term use in the clinical setting. In six pigs Doppler flowmeters were positioned around the hepatic artery and portal vein for the measurement of total liver blood flow. Liver perfusion was quantified by thermodiffusion and compared to H(2) clearance as an established technique under baseline conditions, during different degrees of portal venous obstruction and during occlusion of the hepatic artery. Thermodiffusion measurements were recorded for five days postoperatively followed by histological evaluation of the hepatic puncture site. Perfusion data obtained by thermodiffusion were significantly correlated to H(2) clearance (r = 0.94, P < 0. 001) and to liver blood flow (r = 0.9, P < 0.05). The agreement between thermodiffusion and H(2) clearance was excellent (mean difference -2.1 ml/100 g/min; limits of agreement -12.5 and 8.3 ml/100 g/min). Occlusion of the portal vein or hepatic artery was immediately detected by thermodiffusion, indicating a decrease of perfusion by 64 +/- 7% or 27 +/- 5% of baseline, respectively. Perfusion values at baseline and during vascular occlusion were reproducible during the entire observation period. Histological changes of the liver tissue adjacent to the thermodiffusion probes were minute and did not influence long-term measurements. In vivo validation proved that enhanced thermodiffusion is a minimally invasive technique for the continuous, real-time quantification of hepatic microcirculation. Changes in liver perfusion can be safely detected over several days postoperatively. The implication for liver transplantation has led to the clinical application of thermodiffusion.  相似文献   

6.
In seven anesthetized dogs the effects of intravenously administered prostaglandin E1 on mesenteric arterial and portal venous blood flows and pancreatic capillary blood flow were measured with a transit-time ultrasonic volume flowmeter and a laser Doppler flowmeter. Basal blood flow of the superior mesenteric artery and of the portal vein were 5.7 +/- 0.6 and 11.2 +/- 1.0 ml/min/kg, respectively. Prostaglandin E1 caused a dose-dependent increase in these blood flows. The maximal effect was observed at a dose of 1.0 microgram/kg, when the superior mesenteric arterial blood flow increased 117.9 +/- 3.2% and the portal venous blood flow increased 99.4 +/- 1.7%. Prostaglandin E1 produced an initial rapid increase, followed by a decrease in pancreatic capillary blood flow. The results indicate that the flowmeters used in the present study are widely available for the study of splanchnic circulation and may have a possibility for clinical application.  相似文献   

7.
A method of measuring volumetric flow in human arteries with pulsed Doppler technique was developed. Doppler flowmetry was assessed in 11 adult patients whose admission-diagnoses included aneurysm of the aorta or dissections. During surgery, regional blood flows of the left common carotid artery, terminal aorta, common iliac artery, external iliac artery or common femoral artery were measured by Doppler method and electromagnetic flowmeter. Eighty four arterial flow determinations were obtained from the 11 patients studied. On comparison of simultaneous electromagnetic and Doppler measurements of blood flow, an excellent correlation (r = 0.93) was found between the two methods. The slope of the regression line was 0.587. Regional blood flow was measured with Doppler flowmetry in another 9 patients. The values of the left common carotid, celiac, superior mesenteric and terminal aortic flows were 251 +/- 62, 608 +/- 399, 687 +/- 381, 783 +/- 324 ml.min-1, respectively. This method provides an easy, reliable way of measuring regional blood flow.  相似文献   

8.
A comparative study of splanchnic hemodynamics was made in 12 patients with idiopathic portal hypertension and in eight patients with chronic persistent hepatitis, but without portal hypertension, who served as the control. Venous pressures were measured by portal and hepatic vein catheterizations, blood flow by the pulsed Doppler flowmeter, and organ volume by computed tomography. Splenic artery blood flow was 788 +/- 242 ml/min in idiopathic portal hypertension and about four times that in chronic persistent hepatitis (215 +/- 42 ml/min), whereas there was no difference in superior mesenteric artery blood flow between the former and the latter (408 +/- 142 vs. 389 +/- 32 ml/min). Spleen volume in idiopathic portal hypertension was six times that in chronic persistent hepatitis, and splenic artery blood flow showed a significant linear correlation with spleen volume in idiopathic portal hypertension (r = 0.71, p less than 0.02). The sum of splenic artery blood flow and superior mesenteric artery blood flow in idiopathic portal hypertension was 1195 +/- 294 ml/min, twice that in chronic persistent hepatitis (603 +/- 109 ml/min). Portal vascular resistance and intrahepatic portal vascular resistance were three times and four times those in chronic persistent hepatitis, respectively. These results indicate that both increased intrahepatic portal vascular resistance and increased splenic artery blood flow may play roles in the development of portal hypertension in idiopathic portal hypertension.  相似文献   

9.
We investigated the variability of quantitative duplex Doppler measurements of portal flow. Measurements were validated in vitro using a flow phantom. The measured flow Q (ml/min), is related to the actual phantom output P (ml/min) according to the following formula: Q = 1.08 (P + 44) (r = 0.998). To estimate inter- and intra-observer variance, 38 subjects without portal hypertension were examined in two groups. Two observers examined the first group of subjects (n = 19), from a routine daily ultrasound schedule. Significant differences were found in mean +/- S.D. portal flow (692 +/- 182 ml/min vs. 613 +/- 185 ml/min, p = 0.04) and mean +/- S.D. velocity (15.3 +/- 3.9 cm/s vs. 13.2 +/- 2.6 cm/s, p = 0.01). The combined inter- and intra-observer coefficient of variation (S.D.) was 24% (158 ml/min), 9% (0.92 mm) and 24% (3.4 cm/s) for portal flow, diameter and velocity respectively. Non-systematic components of variance were the largest. Patient characteristics, age, sex, height, weight and body surface area did not influence measurement variations. In the second group of healthy volunteers (n = 19), where variance in measurements over 3 consecutive days was comparable to the combined variance in the first group, the non-systematic variance component was also the largest. We conclude that quantitative duplex Doppler measurements of portal venous flow are mainly subject to non-systematic variability. A coefficient of variation of 24% can be expected in diagnostic measurements in a single patient. Examination by a single observer is advisable. The value of this technique lies in the analysis of pathophysiological mechanisms in portal flow changes in large groups of subjects.  相似文献   

10.
BACKGROUND: Lanreotide, a new long-acting somatostatin analogue, has been shown to inhibit the meal-stimulated increase of splanchnic blood flow in healthy volunteers. To date, similar data in patients with liver cirrhosis have not been available. We have examined the effect of lanreotide compared with placebo on meal-stimulated portal blood flow in patients with liver cirrhosis using Doppler ultrasound. METHODS: 20 cirrhotic patients (placebo n = 12, lanreotide n = 8) with proven portal hypertension were studied after an overnight fast. Lanreotide, at a dose of 100 microg/h, was infused intravenously over 7 h after a 1-hour basal period. In parallel to the intravenous infusion, a liquid test meal (Ensure plus, 1.5 kcal/min) was perfused for 7 h through an intraduodenal tube at a rate of 3 ml/min. Blood pressure, heart rate and portal vein blood flow (PVF, ml/min, Doppler technique) were determined at regular intervals. RESULTS: Baseline PVF amounted to 725 +/- 182 ml/min in the placebo and to 917 +/- 252 ml/min in the lanreotide group (n.s.). The meal-stimulated increase in PVF was blunted by lanreotide (AUC, % x min): 62,709.6 +/- 6,817 (placebo) vs. 45,237 +/- 2,507 (lanreotide), p < 0.05. Lanreotide also blunted the postprandial increase in heart rate for the first 2 h of meal perfusion. CONCLUSIONS: Because of potent inhibition of postprandial splanchnic hyperemia in patients with liver cirrhosis, lanreotide may be useful in the treatment of complications of portal hypertension.  相似文献   

11.
BACKGROUND: Endoscopic ultrasound (EUS) is a new modality allowing real-time flow measurements by means of the Doppler technique. The aim of the study was to evaluate azygos blood flow measurements by endoscopic ultrasound. METHODS: Measurements of azygos blood flow by EUS and by the thermodilution technique were compared in 20 patients with portal hypertension. The ability of EUS flowmetry to detect changes in the azygos and portal venous flow after an intravenous dose of 2 mg of terlipressin was evaluated in 13 of the patients in a double-blind, randomized, placebo-controlled, cross-over design. RESULTS: The EUS Doppler and thermodilution measurements correlated significantly (R=0.81, P < 0.001). The azygos blood flow was found to be 14% higher by the EUS method than by thermodilution. The coefficient of variation of the EUS Doppler measurements of the azygos blood flow was 14.8%. After administration of terlipressin, the azygos blood flow, as measured by EUS Doppler, decreased significantly by 23% from 915 to 704 ml/min (P = 0.014) and the portal venous flow decreased by 28% from 1170 to 789 ml/min (P = 0.03). No effects of placebo were detected. CONCLUSIONS: These results show that EUS measurement of the azygos blood flow correlate strongly to the measurements by the thermodilution technique, and EUS is moreover well tolerated by the patients. The method is applicable for monitoring pharmacological effects on the superior porto-systemic collateral circulation and portal venous flow in patients with portal hypertension.  相似文献   

12.
We studied the effects of endoscopic sclerotherapy with transhepatic variceal obliteration on portal hemodynamics in 20 patients with cirrhosis (six with a spontaneous splenorenal shunt and 14 without it). Portal venous flow 1 month after combined therapy (measured by pulsed Doppler flowmeter) was significantly increased compared with that before therapy (n = 20, 843 +/- 339 vs. 669 +/- 253 ml/min, p less than 0.001). Portal vein catheterization and portal venous flow measurement were repeated 18 months after therapy in eight patients without a splenorenal shunt before therapy and in two patients with a splenorenal shunt before therapy. Two of the former developed a splenorenal shunt. In these 10 patients, portal venous flow before, one month, and 18 months after therapy was 617 +/- 219, 784 +/- 227, and 720 +/- 224 ml/min, respectively, and in 8 of 10 patients the portal venous flow at 18 months remained similar to the values at one month. Portal vein pressures were not significantly elevated 18 months after therapy (35.4 +/- 6.4 vs. 33.6 +/- 5.1 cm H2O) and the mean portal vein pressure change was 2.75 cm H2O (range -6 to +7.5 cm H2O). To summarize, portal venous flow was significantly increased one month after combined sclerotherapy in cirrhotics, the portal venous flow at 18 months remained similar to the values at 1 month in most patients, and the change in portal vein pressure after therapy was small.  相似文献   

13.
INTRODUCTIONThere are many studies on inflow to the liver in liver cirrhosis (LC) in relation to hepatic dysfunction and portal hypertension. In LC, there are changes in liver parenchyma as well as alteration of hepatic vasculature, including morphologica…  相似文献   

14.
K M Carlisle  M Halliwell  A E Read    P N Wells 《Gut》1992,33(1):92-97
The volume flow rate of blood in the portal vein and the hepatic artery was measured using a duplex ultrasound system. Two sections of the hepatic artery were studied; the common hepatic artery where measurements were made just after the bifurcation of the coeliac axis to splenic and hepatic arteries and the hepatic artery itself, where measurements were made just proximal to the porta hepatis in a straight stretch of artery overlying the portal vein. Total hepatic blood flow was taken as the sum of hepatic artery and portal vein flows. A group of 10 normal healthy volunteers in the fasting state was studied. The mean (SD) volume blood flow in the vessels was measured to be: hepatic artery 3.5 (45%) ml/min/kg, common hepatic artery 6.9 (30%) ml/min+/kg, portal vein 13.5 (21%) ml/min/kg, total hepatic flow 17.0 (16%) ml/min/kg.  相似文献   

15.
A newly developed pulsed ultrasound Doppler meter was used for measurement of blood flow in aortocoronary vein grafts during operation. The results were compared with measurements obtained with conventional electromagnetic flowmetry. In 27 grafts, excellent agreement was found between electromagnetic flow probes thoroughly calibrated for varying hematocrit on fresh veins in vitro, and a clip-on type of Doppler probe (r = 0.86). In vitro calibration showed a close correspondence (r = 0.98) with the Doppler technique with no dependency on hematocrit and no need for zero calibration. The use of a conventional electromagnetic flowmeter showed strong dependency on recent calibration, both for saline and for varying hematocrit. Zero-calibration was necessary for every single graft measurement. The application of ultrasound Doppler meters of high quality together with clip-on probes of proper design proved to be superior to electromagnetic flowmetry for intraoperative blood flow measurements.  相似文献   

16.
BACKGROUND/AIMS: Portal vein thrombosis is a frequent postoperative complication after esophagogastric devascularization with splenectomy. The aim of this study was to analyze biochemical, hematological, coagulation blood tests and intraoperative portal vein hemodynamics after surgical treatment of hepatosplenic Mansonic schistosomal portal hypertension. METHODOLOGY: Forty patients with hepatosplenic schistosomiasis with indication for surgical treatment were prospectively studied. All patients underwent routine pre- and postoperative biochemical, hematologic, coagulation blood tests and intraoperative portal hemodynamic evaluation (portal pressure and portal flow) before and after esophagogastric devascularization and splenectomy using a 4-F thermodilution catheter introduced inside the portal vein. RESULTS: Portal vein thrombosis, diagnosed by routine postoperative Doppler ultrasonography was found in 22 patients (55%). It was partial in nineteen and total in three. In patients with postoperative portal thrombosis, we observed a reduction in portal flow of 971 +/- 592 mL/min (42 +/- 16%) at the end of the surgery, while this reduction was of 720 +/- 644mL/ min (33 +/- 30%) in those with postoperative pervious portal vein (p = 0.245). The decrease in portal pressure was the same in both groups: 7.2 +/- 3.0 mmHg (23 +/- 10%) and 7.6 +/- 3.8 mmHg (27 +/- 14%) with and without thrombosis respectively (p=0.759). There was also no significant difference between patients with and without portal vein thrombosis regarding pre- and postoperative hemoglobin level or platelet levels, coagulation tests, portal vein diameter and spleen's weight. CONCLUSIONS: Portal vein thrombosis was observed in 55% of the patients but this complication did not show any correlation with the decrease in portal flow or pressure or with biochemical, hematologic, coagulation blood tests, portal vein diameter or spleen's weight.  相似文献   

17.
The purpose of this study was to examine the hemodynamic changes of the spleen and the subsequent influence on the numbers of blood cells both during and 1 month after distal splenorenal shunt (DSRS) with splenopancreatic disconnection in 20 patients with portal hypertension. The intraoperative splenic blood flow, measured with an electromagnetic flowmeter, significantly increased after shunt insertion: the mean percentage increases within the splenic vein and artery were 60% (p less than 0.01) and 37% (p less than 0.05), respectively. The splenic venous blood flow, measured with a pulsed Doppler flowmeter, had not changed significantly 1 month postoperatively (676 +/- 501 to 540 +/- 306 ml/min). The WBC and platelet counts significantly (p less than 0.05 and p less than 0.01, respectively) increased 1 month postoperatively, whereas there was a small, but significant (p less than 0.05), decrease in RBC count. We concluded that splenic blood flow increases immediately after DSRS with splenopancreatic disconnection, but this increase may be only short term. The influence of the postoperative hemodynamic changes on blood cell count is uncertain.  相似文献   

18.
Alcoholic liver disease is frequently accompanied by portal hypertension. We have previously shown that alcohol intake in awake, unrestrained rats is followed by an increase in portal tributary blood flow. In this study, the effect of ethanol on splanchnic hemodynamics in rats with portal hypertension was analyzed. Portal hypertension was induced by partial ligation of the portal vein. This procedure resulted in an increase in portal tributary and hepatic arterial blood flows compared to sham-operated animals. Ethanol (2 gm per kg, oral) increased portal tributary blood flow in both sham-operated and portal vein-ligated rats (sham + water = 37.6 +/- 1.4; sham + ethanol = 63.1 +/- 1.9; p less than 0.01; partial portal vein stenosis + water = 53.2 +/- 3.3; partial portal vein stenosis + ethanol = 69.5 +/- 2.2 ml.kg-1.min-1; p less than 0.01). In sham-operated rats, hepatic artery blood flow was unchanged following ethanol (sham + water = 6.6 +/- 0.7; sham + ethanol = 7.1 +/- 1.0 ml.kg-1.min-1), whereas in portal vein-ligated rats, flow was increased (partial portal vein stenosis + water = 13.7 +/- 1.4; partial portal vein stenosis + ethanol = 19.8 +/- 1.1 ml.kg-1.min-1; p less than 0.025). The adenosine receptor blocker 8-phenyltheophylline suppressed only the ethanol-induced increase in both portal tributary and hepatic artery blood flows in portal vein-ligated rats. The increases in hepatic artery and portal tributary blood flows observed in portal vein-ligated rats without ethanol were not influenced by 8-phenyltheophylline.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Liver blood flow and systemic hemodynamics were measured intraoperatively in 34 patients after liver transplantation. Ultrasound transit-time flow probes measured hepatic arterial and portal venous flow over 10 to 75 min 1 to 3 hr after reperfusion. Cardiac output was measured by thermodilution. Mean cardiac output was 9.5 +/- 2.8 L/min; the mean total liver blood flow of 2,091 +/- 932 ml/min was 23% +/- 11% of cardiac output. Mean portal flow of 1,808 +/- 929 ml/min was disproportionately high at 85% +/- 10% of total liver blood flow. Correlation analysis showed a significant (p less than 0.01; r = 0.42) correlation between cardiac output and portal venous flow and a trend toward negative correlation (p = 0.087) between cardiac output and hepatic arterial flow. These data show that increased flow in the newly transplanted liver is predominantly portal venous flow and is associated with high cardiac output and reduced hepatic arterial flow. In the last 13 patients studied, portal flow was reduced by 50% and the hepatic artery response was measured. We saw a significant (p less than 0.05) increase in hepatic artery flow from 322 +/- 228 to 419 +/- 271 ml/min, indicating an intact hepatic arterial buffer response. The hepatic artery response also showed that it is a reversible rather than a fixed resistance that contributes to the low hepatic artery flow in these patients.  相似文献   

20.
A method to quantitate blood flow through the gastroesophageal collaterals in portal hypertensive patients was developed. Since gastroesophageal collaterals drain into the azygos system, it is postulated that measurement of blood flow in the azygos vein should provide a quantitative measurement of gastroesophageal collateral blood flow changes in portal hypertensive patients. Azygos blood flow was measured using a double thermodilution catheter directed under fluoroscopy to the azygos vein. Ten patients with alcoholic cirrhosis were studied. Five of these patients had a history of repeated bleeding from gastroesophageal varices (Group I). The azygos blood flow in these patients was 596 +/- 78 ml per min. The other five patients all had decompressive surgery of the portal system (Group II). In these patients the azygos venous blood flow was 305 +/- 29 ml per min (p less than 0.01). The coefficient of variation of repeated baseline measurements was of 4.4 +/- 0.6%. The azygos venous blood flow measurement is a rapid, simple and sensitive method to evaluate blood flow changes in the vessels involved in gastroesophageal bleeding due to portal hypertension.  相似文献   