1.
Although the force/pressure applied onto a textile substrate through a uniaxial compression is constant and independent of the yarn direction, it should be noted that such mechanical action causes a geometric change in the substrate, which can be identified by the reduction in its lateral thickness. Therefore, the objective of this study was to investigate the influence of the fabric orientation on both knitted and woven pressure sensors, in order to generate knowledge for a better design process during textile piezoresistive sensor development. For this purpose, these distinct textile structures were doped with different concentrations of graphene nanoplatelets (GNPs), using the screen-printing technique. The chemical and physical properties of these screen-printed fabrics were analysed using Field Emission Scanning Electron Microscopy, Ground State Diffuse Reflectance and Raman Spectroscopy. Samples were subjected to tests determining linear electrical surface resistance and piezoresistive behaviour. In the results, a higher presence of conductive material was found in woven structures. For the doped samples, the electrical resistance varied between 105 Ω and 101 Ω, for the GNPs’ percentage increase. The lowest resistance value was observed for the woven fabric with 15% GNPs (3.67 ± 8.17 × 101 Ω). The samples showed different electrical behaviour according to the fabric orientation. Overall, greater sensitivity in the longitudinal direction and a lower coefficient of variation CV% of the measurement was identified in the transversal direction, coursewise for knitted and weftwise for woven fabrics. The woven fabric doped with 5% GNPs assembled in the weftwise direction was shown to be the most indicated for a piezoresistive sensor, due to its most uniform response and most accurate measure of mechanical stress.  相似文献   

2.
Textile ballistic shields are the basis of protection against bullets and fragments with low kinetic energy. They are usually made of para-aramid fabrics or unidirectional structure (UD) sheets of ultra-high molecular weight polyethylene (UHMWPE). The aim of the research presented in the article was to obtain ballistic packages made of embroidered structures and to compare their ballistic properties with those of woven structures in terms of deformation of the standardized ballistic substrate after impact with a 9 mm bullet at a velocity of 380 ± 3 m/s. Using the tailored fiber placement method, embroidered structures were fabricated by embroidering two sets of para-aramid threads at an angle of 90°. As the woven structures, the use of para-aramid fabric made of the same yarn and with a surface weight comparable to that of embroidered structures was adopted. Ballistic packages consisted of 26 layers in five variants, also taking into account the hybrid arrangement of woven and embroidered layers. Ballistic tests have shown that the best ballistic properties have hybrid packages made by folding 13 woven and then 13 embroidered layers, where the maximum deformation of the plasticine substrate is below 23 mm. The conducted research confirmed that embroidered structures in appropriate combination with woven structures can significantly improve the ballistic properties of textile packages.  相似文献   

3.
Flexible sensors have attracted extensive attention because of their promising applications in the fields of health monitoring, intelligent robots, and electronic skin, etc. During the COVID-19 epidemic, noncontact control of public equipment such as elevators, game consoles, and doors has become particularly important, as it can effectively reduce the risk of cross-infection. In this work, a noncontact flexible temperature sensor is prepared via a simple dip-drying progress, in which poly(3,4-ethylenedioxythiophene):poly(4-styrene sulfonate) (PEDOT:PSS) and printer paper served as the sensing material and the flexible substrate, respectively. We combined the highly sensitive temperature-responsive property of PEDOT:PSS with the good hygroscopicity of printer paper. The prepared sensor shows high sensitivity and good stability in noncontact sensing mode within the temperature range of 20–50 °C. To prove the practicability of the noncontact temperature sensor, a 3 × 2 sensing array is prepared as a noncontact human-machine interface to realize the interaction between player and “Pound-A-Mole game” and a Bluetooth car. These two demos show the sensor′s ability to perceive nearby temperature changes, verifying its application potential as a noncontact human-machine interaction interface.  相似文献   

4.
Summary A needle-type glucose sensor has been developed using a platinum electrode covered with immobilized glucose oxidase. Experiments with albumin-saline solution in vitro showed that at 5.5 mmol/l glucose concentration the output current generated was 1.2±0.4 nA (mean ± SD). The current increased as a linear function of glucose concentration over the range (0–27.7 mmol/l). The response time to reach 90% of the final plateau value was 16.2±6.2 s. The signal-to-noise ratio of the sensor was 15.8±2.6 decibels. The temperature coefficient in output was 2.3±1.0%/°C. The current output was not affected significantly by changes in oxygen tension of the solution in the range 25–150 mmHg.In vivo, the output current of sensors inserted into the subcutaneous tissues of dogs was directly related to blood glucose concentrations after oral glucose or meals. Daily checking of the sensors maintained in subcutaneous tissues in five dogs showed that the sensitivity decreased gradually to 87.2±7.6% at 72 h, and dropped significantly to 57.4±7.0% of the initial output by 96 h.A wearable artificial endocrine pancreas (18.0 × 17.7 × 7.9 cm, 700 g) was developed, consisting of a needle-type glucose sensor, a microcomputer system and a pump driving mechanism. Three pancreatectomized dogs were fitted with the system by inserting the sensor into subcutaneous tissue. By renewing the sensor every fourth day, the device could maintain the daily glucose variations in diabetic dogs within the range 5–9.5 mmol/l for 7 days.  相似文献   

5.
The intersection between nanoscience and additive manufacturing technology has resulted in a new field of printable and flexible electronics. This interesting area of research tackles the challenges in the development of novel materials and fabrication techniques towards a wider range and improved design of flexible electronic devices. This work presents the fabrication of a cost-effective and facile flexible piezoresistive pressure sensor using a 3D-printable carbon nanotube-based nanocomposite. The carbon nanotubes used for the development of the material are multi-walled carbon nanotubes (MWCNT) dispersed in polydimethylsiloxane (PDMS) prepolymer. The sensor was fabricated using the direct ink writing (DIW) technique (also referred to as robocasting). The MWCNT-PDMS composite was directly printed onto the polydimethylsiloxane substrate. The sensor response was then examined based on the resistance change to the applied load. The sensor exhibited high sensitivity (6.3 Ω/kPa) over a wide range of applied pressure (up to 1132 kPa); the highest observed measurement range for MWCNT-PDMS composite in previous work was 40 kPa. The formulated MWCNT-PDMS composite was also printed into high-resolution 3-dimensional shapes which maintained their form even after heat treatment process. The possibility to use 3D printing in the fabrication of flexible sensors allows design freedom and flexibility, and structural complexity with wide applications in wearable or implantable electronics for sport, automotive and biomedical fields.  相似文献   

6.
Temperature sensors have been widely applied in daily life and production, but little attention has been paid to the research on temperature sensors based on surface plasmon resonance (SPR) sensors. Therefore, an SPR temperature sensor with a triple structure of titanium dioxide (TiO2) film, gold (Au) film, and TiO2 nanorods is proposed in this article. By optimizing the thickness and structure of TiO2 film and nanorods and Au film, it is found that the sensitivity of the SPR temperature sensor can achieve 6038.53 nm/RIU and the detection temperature sensitivity is −2.40 nm/°C. According to the results, the sensitivity of the optimized sensor is 77.81% higher than that of the sensor with pure Au film, which is attributed to the TiO2(film)-Au-TiO2(nanorods) structure. Moreover, there is a good linear correlation (greater than 0.99) between temperature and resonance wavelength in the range from 0 °C to 60 °C, which can ensure the detection resolution. The high sensitivity, FOM, and detection resolution indicate that the proposed SPR sensor has a promising application in temperature monitoring.  相似文献   

7.
Three-dimensional microstructures play a key role in the fabrication of flexible electronic products. However, the development of flexible electronics is limited in further applications due to low positioning accuracy, the complex process, and low production efficiency. In this study, a novel method for fabricating three-dimensional circular truncated cone microstructures via low-frequency ultrasonic resonance printing is proposed. Simultaneously, to simplify the manufacturing process of flexible sensors, the microstructure and printed interdigital electrodes were fabricated into an integrated structure, and a flexible pressure sensor with microstructures was fabricated. Additionally, the effects of flexible pressure sensors with and without microstructures on performance were studied. The results show that the overall performance of the designed sensor with microstructures could be effectively improved by 69%. Moreover, the sensitivity of the flexible pressure sensor with microstructures was 0.042 kPa−1 in the working range of pressure from 2.5 to 10 kPa, and the sensitivity was as low as 0.013 kPa−1 within the pressure range of 10 to 30 kPa. Meanwhile, the sensor showed a fast response time, which was 112 ms. The stability remained good after the 100 cycles of testing. The performance was better than that of the flexible sensor fabricated by the traditional inverted mold method. This lays a foundation for the development of flexible electronic technology in the future.  相似文献   

8.
The influence of the Ar/O2 gas ratio during radio frequency (RF) sputtering of the RuO2 sensing electrode on the pH sensing performance is investigated. The developed pH sensor consists in an RF sputtered ruthenium oxide thin-film sensing electrode, in conjunction with an electroplated Ag/AgCl reference electrode. The performance and characterization of the developed pH sensors in terms of sensitivity, response time, stability, reversibility, and hysteresis are investigated. Experimental results show that the pH sensor exhibits super-Nernstian slopes in the range of 64.33–73.83 mV/pH for Ar/O2 gas ratio between 10/0–7/3. In particular, the best pH sensing performance, in terms of sensitivity, response time, reversibility and hysteresis, is achieved when the Ar/O2 gas ratio is 8/2, at which a high sensitivity, a low hysteresis and a short response time are attained simultaneously.  相似文献   

9.
Resistive pressure sensors are appealing due to having several advantages, such as simple reading mechanisms, simple construction, and quick dynamic response. Achieving a constantly changeable microstructure of sensing materials is critical for the flexible pressure sensor and remains a difficulty. Herein, a flexible, tunable resistive pressure sensors is developed via simple, low-cost microsphere self-assembly and graphene/carbon nanotubes (CNTs) solution drop coating. The sensor uses polystyrene (PS) microspheres to construct an interlocked dome microstructure with graphene/CNTs as a conductive filler. The results indicate that the interlocked microdome-type pressure sensor has better sensitivity than the single microdome-type and single planar-type without surface microstructure. The pressure sensor’s sensitivity can be adjusted by varying the diameter of PS microspheres. In addition, the resistance of the sensor is also tunable by adjusting the number of graphene/CNT conductive coating layers. The developed flexible pressure sensor effectively detected human finger bending, demonstrating tremendous potential in human motion monitoring.  相似文献   

10.
The measurement of pH has received great attention in diverse fields, such as clinical diagnostics, environmental protection, and food safety. Optical fiber sensors are widely used for pH sensing because of their great advantages. In this work, an optical fiber pH sensor is fabricated, by combining the merits of the multimode interference configuration and pH-sensitive polyaniline/polyacrylic acid (PAni/PAA) coatings, which was successfully in situ deposited on the no-core fiber (NCF) by the layer-by-layer (LBL) self-assembly method. The sensors’ performance was experimentally characterized when used for pH detection. It has a high sensitivity of 0.985 nm/pH and a great linear response in a universal pH range of 2–12. The response time and recovery time is measured to be less than 10 s. In addition, its temperature sensitivity is tested to be about 0.01 nm/°C with a low temperature crosstalk effect, which makes it promising for detecting pH in the liquid phase with temperature variation. The sensors also demonstrated easy fabrication, good stability, and repeatability, which are adapted to pH detection in most practical applications.  相似文献   

11.

Background

Glucose monitoring systems using subcutaneously inserted sensors are currently labeled for up to 7 days of wear. In this study, we evaluated the feasibility of a 14-day wear duration using a modified version of the sensor found in the Freestyle Navigator™ continuous glucose monitoring system.

Methods

Sixty-two subjects with diabetes were enrolled in the study. One sensor per subject was inserted on the arm for a wear time of 14 days. Two different calibration algorithms were applied retrospectively, one that uses periodic sensor recalibrations and one without recalibrations. Sensor in vivo stability was determined by least square regression analysis using capillary blood glucose. Mean absolute relative difference (MARD) and mean relative difference were calculated. Consensus error grid analysis was performed by day and over the 14-day wear period to evaluate accuracy of both systems. The sensor insertion sites were inspected after sensor removal for skin reactions.

Results

Sensor data from 55 subjects were used for the analysis. The accuracy metrics for the system with recalibration were calculated to MARD = 13.9% and 84.0% in zone A (error grid analysis). The system without recalibration performed significantly better, resulting in MARD of 12.2% and 88.0% in zone A (p < .0001). The maximum change of in vivo sensor sensitivity over the 14-day wear period was 2% per day. Two subjects reported pain during the first 5 days of sensor wear, and 1 subject reported itching at the sensor site. No further skin reactions were noticed.

Conclusions

The study shows that a 14-day sensor wear period is achievable. Moreover, sensors using “wired enzyme” technology showed excellent in vivo stability, with no significant sensitivity loss over the 14-day wear period.  相似文献   

12.
Flexible pressure sensors are widely used in different fields, especially in human motion, robot monitoring and medical treatment. Herein, a flexible pressure sensor consists of the flat top plate, and the microstructured bottom plate is developed. Both plates are made of polydimethylsiloxane (PDMS) by molding from the 3D printed template. The contact surfaces of the top and bottom plates are coated with a mixture of poly (3,4-ethylenedioxythiophene) poly (styrene sulfonate) (PEDOT:PSS) and polyurethane dispersion (PUD) as stretchable film electrodes with carbon nanotubes on the electrode surface. By employing 3D printing technology, using digital light processing (DLP), the fabrication of the sensor is low-cost and fast. The sensor models with different microstructures are first analyzed by the Finite Element Method (FEM), and then the models are fabricated and tested. The sensor with 5 × 5 hemispheres has a sensitivity of 3.54 × 10−3 S/kPa in the range of 0–22.2 kPa. The zero-temperature coefficient is −0.0064%FS/°C. The durability test is carried out for 2000 cycles, and it remains stable during the whole test. This work represents progress in flexible pressure sensing and demonstrates the advantages of 3D printing technology in sensor processing.  相似文献   

13.
A new design of a triple band perfect metamaterial absorber based on Pythagorean fractal geometry is proposed and analyzed for terahertz sensing applications. The proposed design showed an enhanced sensing performance and achieved three intensive peaks at 33.93, 36.27, and 38.39 THz, corresponding to the absorptivity of 98.5%, 99.3%, and 99.6%, respectively. Due to the symmetrical nature of the recommended design, the structure exhibited the characteristics of independency on the incident wave angles. Furthermore, a parametric study was performed to show the effects of the change in substrate type, resonator material, and substrate thickness on the absorption spectrum. At a fixed analyte thickness (0.5 μm), the resonance frequency of the design was found to be sensitive to the refractive index of the surrounding medium. The proposed design presented three ultra-sensitive responses of 1730, 1590, and 2050 GHz/RIU with the figure of merit (FoM) of 3.20, 1.54, and 4.28, respectively, when the refractive index was changed from 1.0 to 1.4. Additionally, the metamaterial sensor showed a sensitivity of 1230, 2270, and 1580 GHz/μm at the three resonance frequencies, respectively, when it was utilized for the detection of thickness variation at a fixed analyte refractive index (RI) of 1.4. As long as the RI of the biomedical samples is between 1.3 and 1.4, the proposed sensor can be used for biomedical applications.  相似文献   

14.
Background:The feasibility of measuring β-hydroxybutyrate in ISF using a continuous ketone monitoring (CKM) sensor using a single calibration without further adjustments over 14 days is described.Methods:A CKM sensor was developed using wired enzyme technology with β-hydroxybutyrate dehydrogenase chemistry. In vitro characterization of the sensor was performed in phosphate buffered saline at 37°C. In vivo performance was evaluated in 12 healthy participants on low carbohydrate diets, who wore 3 ketone sensors on the back of their upper arms to continuously measure ketone levels over 14 days. Reference capillary ketone measurements were performed using Precision Xtra® test strips at least 8 times a day.Results:The sensor is stable over 14 days and has a linear response over the 0-8 mM range. The operational stability of the sensor is very good with a 2.1% signal change over 14 days. The first human study of the CKM sensor demonstrated that the sensor can continuously track ketones well through the entire 14 days of wear. The performance with a single retrospective calibration of the sensor showed 82.4% of data pairs within 0.225 mM/20% and 91.4% within 0.3 mM/30% of the capillary ketone reference (presented as mM at <1.5 mM and as percentage at or above 1.5 mM). This suggests that the sensor can be used with a single calibration for the 14 days of use.Conclusions:Measuring ketones in ISF using a continuous ketone sensor is feasible. Additional studies are required to evaluate the performance in intended patient populations, including conditions of ketosis and diabetic ketoacidosis.  相似文献   

15.
The main purpose of this article is to monitor the natural frequency of stainless steel (SS304) with and without defect by spray-coated smart graphene nanoplatelet (GNPs)-doped poly (methyl methacrylate) (PMMA) nanocomposite strain sensor and human health by smart Lycra denim textile sensor. Methods such as impact hammer test and NI-daq, finite element method (FEM) simulation by Abaqus 6.12, and fast Fourier transform (FFT) study were applied for frequency monitoring of SS304. For human health monitoring, edema disease inspection, cough, and biceps locomotion were studied by graphene sol–gel textile sensor. We report eight sensors fabricated by scotch tape exfoliation method and their sensitivity was checked in terms of gauge factor (GF). The highest and lowest GF-based sensors were checked for sensitivity in the defect (hole) specimen. These sensors were used to sense the natural frequency of SS304 at three different positions in the cantilever beam. The same quantity of GNPs was used for making Lycra denim textile sensors for human health monitoring. The Lycra denim textile sensor showed a 216% change in resistance in the left calf muscle, which is less than right leg flexibility, indicating good sensitivity. In addition, the textile sensor helped in sensing coughing and biceps monitoring. The ease in fabrication and high sensitivity demonstrate the potential ability of GNPs for futuristic smart material for structural and human health monitoring.  相似文献   

16.
Summary A miniaturized amperometric, enzymatic, glucose sensor (outer diameter 0.45 mm) was evaluated after implantation in the subcutaneous tissue of normal rats. A simple experimental procedure was designed for the long-term assessment of the sensor's function which was performed by recording the current during an intraperitoneal glucose load. The sensor was calibrated by accounting for the increase in the current during the concomitant increase in plasma glucose concentration, determined in blood sampled at the tail vein. This made it possible to estimate the glucose concentration in subcutaneous tissue. During the glucose load, the change in subcutaneous glucose concentration followed that in blood with a lag time consistently shorter than 5 min. The estimations of subcutaneous glucose concentration during these tests were compared to the concomitant plasma glucose concentrations by using a grid analysis. Three days after implantation (n=6 experiments), 79 estimations were considered accurate, except for five which were in the acceptable zone. Ten days after implantation (n=5 experiments), 101 estimations were accurate, except for one value, which was still acceptable. The sensitivity was around 0.5 nA mmol–1·l–1 on day 3 and day 10. A longitudinal study on seven sensors tested on different days demonstrated a relative stability of the sensor's sensitivity. Finally, histological examination of the zone around the implantation site revealed a fibrotic reaction containing neocapillaries, which could explain the fast response of the sensor to glucose observed in vivo, even on day 10. We conclude that this miniaturized glucose sensor, whose size makes it easily implanted, works for at least ten days after implantation into rat subcutaneous tissue.  相似文献   

17.
The soft sensing system has drawn huge enthusiasm for the application of soft robots and healthcare recently. Most of them possess thin-film structures that are beneficial to monitoring strain and pressure, but are unfavorable for measuring normal displacement with high linearity. Here we propose soft tactile sensors based on uniform-strength cantilever beams that can be utilized to measure the normal displacement and force of soft objects simultaneously. First, the theoretical model of the sensors is constructed, on the basis of which, the sensors are fabricated for testing their sensing characteristics. Next, the test results validate the constructed model, and demonstrate that the sensors can measure the force as well as the displacement. Besides, the self-fabricated sensor can have such prominent superiorities as follows—it is ultra-soft, and its equivalent stiffness is only 0.31 N·m−1 (approximately 0.4% of fat); it has prominent sensing performance with excellent linearity (R2 = 0.999), high sensitivity of 0.533 pF·mm−1 and 1.66 pF·mN−1 for measuring displacement and force; its detection limit is as low as 70 μm and 20 μN that is only one-tenth of the touch of a female fingertip. The presented sensor highlights a new idea for measuring the force and displacement of the soft objects with broad application prospects in mechanical and medical fields.  相似文献   

18.
This study aims to investigate the applicability of a hybrid electrochemical sensor composed of cork and graphite (Gr) for detecting caffeine in aqueous solutions. Raw cork (RAC) and regranulated cork (RGC, obtained by thermal treatment of RAC with steam at 380 °C) were tested as modifiers. The results clearly showed that the cork-graphite sensors, GrRAC and GrRGC, exhibited a linear response over a wide range of caffeine concentration (5–1000 µM), with R2 of 0.99 and 0.98, respectively. The limits of detection (LOD), estimated at 2.9 and 6.1 µM for GrRAC and GrRGC, suggest greater sensitivity and reproducibility than the unmodified conventional graphite sensor. The low-cost cork-graphite sensors were successfully applied in the determination of caffeine in soft drinks and pharmaceutical formulations, presenting well-defined current signals when analyzing real samples. When comparing electrochemical determinations and high performance liquid chromatography measurements, no significant differences were observed (mean accuracy 3.0%), highlighting the potential use of these sensors to determine caffeine in different samples.  相似文献   

19.
Skin-like sensitivity, or the capability to recognize tactile information, will be an essential feature of future generations of robots, enabling them to operate in unstructured environments. Recently developed large-area pressure sensors made with organic transistors have been proposed for electronic artificial skin (E-skin) applications. These sensors are bendable down to a 2-mm radius, a size that is sufficiently small for the fabrication of human-sized robot fingers. Natural human skin, however, is far more complex than the transistor-based imitations demonstrated so far. It performs other functions, including thermal sensing. Furthermore, without conformability, the application of E-skin on three-dimensional surfaces is impossible. In this work, we have successfully developed conformable, flexible, large-area networks of thermal and pressure sensors based on an organic semiconductor. A plastic film with organic transistor-based electronic circuits is processed to form a net-shaped structure, which allows the E-skin films to be extended by 25%. The net-shaped pressure sensor matrix was attached to the surface of an egg, and pressure images were successfully obtained in this configuration. Then, a similar network of thermal sensors was developed with organic semiconductors. Next, the possible implementation of both pressure and thermal sensors on the surfaces is presented, and, by means of laminated sensor networks, the distributions of pressure and temperature are simultaneously obtained.  相似文献   

20.
Background:Continuous glucose monitoring using subcutaneously inserted sensors currently requires blood glucose tests for sensor calibration. Alternatively, sensors precalibrated during the manufacturing process may eliminate the need for fingerstick calibrations. In this study we evaluated the feasibility of sensor factory calibration in subjects with diabetes.Methods:A total of 33 subjects with diabetes were asked to wear 4 sensors in parallel, 2 on the arm and 2 on the abdomen. Sensors from a lot with low in vitro sensitivity coefficient of variation were used in the study. Based on frequent capillary blood glucose measurements, the average glucose sensitivity of each sensor was determined over a 5-day wear time. The in vivo sensitivities were analyzed for inter- and intrasubject variation. Mean absolute relative difference (MARD) calculation and consensus error grid analysis (EGA) were performed using a single calibration factor for all sensors, to simulate factory calibration and compared against conventional finger-stick calibration.Results:The sensitivity coefficient of variation between sensors increased from 2.9% in vitro to 6.0% in vivo. No difference in sensor response between subjects (P = .069) as well as between insertion sites (arm and abdomen) was detected (P = .104). Applying one calibration factor to all sensors in the study resulted in an MARD of 13.4%, and 83.5% of the values fell in consensus EGA zone A. Multiple fingerstick calibration resulted in an MARD of 12.7% and 84.1% in zone A.Conclusions:Feasibility of factory calibration was demonstrated in subjects with diabetes using sensors based on “wired enzyme” technology, resulting in accuracy metrics similar to sensors calibrated with capillary blood glucose.  相似文献   