首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BackgroundThe etiology, complications, and rerevision risks of early aseptic revision total hip arthroplasty (THA) within 90 days are insufficiently documented.MethodsA national insurance claims database (PearlDiver Technologies, Fort Wayne, IN) was queried for patients who underwent unilateral aseptic revision THA within 90 days of the index procedure using administrative codes. Patients who underwent revision for infection, without minimum 2-year follow-up, and younger than 18 years were excluded. This cohort was matched based on gender, age, and Charlson Comorbidity Index to a control group of patients who underwent primary THA without revision within 90 days. Two-year rerevision and 90-day complication rates were recorded. Chi-square and Fisher exact tests were used as appropriate for statistical comparison.ResultsFour hundred two patients met the inclusion criteria for early aseptic revision within 90 days of the index procedure and were matched to the control group. The overall 2-year rerevision rate was higher in the early revision group compared with control group (14.9% vs 2.5%, P < .001). Complications within 90 days occurred more frequently in the early revision group, including blood transfusion (10.2% vs 3.2%, P < .001), deep vein thrombosis (9.0% vs 3.2%, P = .001), and pulmonary embolism (2.74% vs 0.75%, P = .031). The most common reasons for early aseptic revision were dislocation (41.5%), fracture (38.1%), and loosening (17.4%).ConclusionEarly aseptic revision THA is associated with significantly higher 90-day complication rates and 2-year rerevision rates compared with a control group of primary THA without revision. The most common reasons for acute early revision were dislocation, fracture, and mechanical loosening.Level of EvidenceLevel III.  相似文献   

2.
BackgroundPatients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study is to assess implant survivorship, radiographic results, and clinical outcomes of contemporary, porous titanium acetabular components in the setting of prior pelvic radiation.MethodsWe retrospectively reviewed 33 patients (38 hips) with prior pelvic radiation between 2006 and 2016 who underwent primary THA. The mean overall pelvic radiation dose was 6300 cGy with a mean latency period to THA of 5 years. The most common acetabular component was Pinnacle (DePuy Synthes) in 76%. Eight-seven percent of cups were fixed with screws. The mean age at primary THA was 74 years, 76% were male, and the mean body mass index was 30 kg/m2. Mean follow-up was 5 years.ResultsThe 10-year survivorship free of revision for aseptic loosening, free of any revision, and free of any reoperation were 100%, 89%, and 89%, respectively, when accounting for death as a competing risk. There were 3 revisions; one each for taper corrosion, recurrent dislocation, and infection. Radiographically, all cups had evidence of osteointegration and none had radiographic evidence of loosening. The mean Harris Hip Score improved from 50 to 84 postoperatively (P < .0001).ConclusionContemporary porous titanium acetabular components with supplemental screws provided excellent implant fixation in patients with prior therapeutic pelvic radiation. At 10 years, 100% of these components were free of revision for aseptic loosening and 100% were radiographically well-fixed.Level of EvidenceLevel IV, Therapeutic.  相似文献   

3.
BackgroundHighly porous-coated titanium acetabular components have a high coefficient of friction and ultraporous surfaces to enhance bone ingrowth and osseointegration in total hip arthroplasty (THA). There have been concerns with the development of early radiolucent lines and aseptic loosening of highly porous acetabular components. It is unclear whether these concerns relate to a specific implant or the entire class. The aim of this study is to compare the revision rates for aseptic loosening of highly porous acetabular combinations in primary THA using data from a large joint replacement registry.MethodsData were retrieved from the Australian Orthopedic Association National Joint Replacement Registry for the study period September 1999 to December 2019. All primary THA procedures recorded and performed for osteoarthritis using the most common combinations for each highly porous acetabular component with highly cross-linked polyethylene and a 32-mm or 36-mm femoral head were included. The primary outcome measure was revision for aseptic loosening of the acetabular component. Results were adjusted for patient age and gender.ResultsThere were 20,993 primary THA procedures performed for osteoarthritis using a highly porous acetabular component across 6 combinations. Relative to the POLARSTEM/R3 (StikTite), the Exeter V40/Tritanium had a significantly higher risk of revision for aseptic loosening of the acetabular component (hazard ratio 0.21, 95% confidence interval 0.06-0.74, P = .014). There was no difference between any other highly porous acetabular component combination and no late revisions for aseptic loosening.ConclusionHighly porous-coated titanium acetabular components have low rates of aseptic loosening with long-term follow-up. A difference between components may exist.Level of EvidenceLevel III.  相似文献   

4.
BackgroundWe sought to evaluate the cause-specific revision risk following hybrid (cemented stem mated to a cementless acetabular implant) vs cementless total hip arthroplasty (THA) in a US cohort.MethodsPrimary elective THA for osteoarthritis was identified using Kaiser Permanente’s Total Joint Replacement Registry (2001-2018). Multivariable Cox regression was used to evaluate cause-specific revision, including aseptic loosening, infection, instability, and periprosthetic fracture (PPF), for hybrid vs cementless THA. Analysis was stratified by age (<65, 65-74, and ≥75 years) and gender.ResultsThe study cohort comprised 88,830 THAs, including 4539 (5.1%) hybrid THAs. In stratified analysis, hybrid THA had a higher revision risk for loosening in females in all 3 age subgroups. A lower risk of revision for PPF was observed following hybrid THA in females aged ≥75 years. For females ≥75 years, cementless THA had an excess PPF risk of 0.9% while hybrid THA had an excess loosening risk of 0.2%, translating to a theoretical prevention of 10 PPF revisions but a price of 3 loosening revisions per 1000 hybrid THAs. No difference in revision risk was observed in males.ConclusionWe observed differences in cause-specific revision risks by method of stem fixation which depended upon patient age and gender. Although the trend toward all cementless fixation continue, there may be a role for hybrid fixation in females ≥75 years to mitigate risk for revision due to PPF at the potential cost of a slight increase in longer term aseptic loosening.Level of EvidenceLevel III.  相似文献   

5.
BackgroundAs indications for elective total hip arthroplasty (THA) expand to younger patients, we sought to (1) compare revision risk following primary elective THA in patients <55 years at the time of their THA to patients aged ≥65 years and (2) identify specific risk factors for revision in patients <55 years.MethodsA Kaiser Permanente's total joint replacement registry was used to conduct a cohort study including primary elective THA patients aged ≥18 (2001-2018). In total, 11,671 patients <55 years and 53,106 patients ≥65 years were included. Multiple Cox regression was used to evaluate cause-specific revision risk, including septic revision, aseptic loosening, instability, and periprosthetic fracture. Stepwise Cox regression was used to identify patient and surgical factors associated with cause-specific revision in patients <55 years.ResultsPatients <55 years had a higher risk of septic revision (hazard ratio [HR] = 1.30, 95% confidence interval [CI] = 1.02-1.66), aseptic loosening (HR = 2.60, 95% CI = 1.99-3.40), and instability (HR = 1.35, 95% CI = 1.09-1.68), but a lower risk of revision for periprosthetic fracture (HR = 0.36, 95% CI = 0.22-0.59) compared to patients aged ≥65 years. In the <55 age group, risk factors for septic revision included higher body mass index, drug abuse, and liver disease. Hypertension, anterior approach, and ceramic-on-ceramic were associated with aseptic loosening. White race, American Society of Anesthesiologists classification ≥3, smoker, paralysis, posterior approach, ceramic-on-ceramic, and smaller head diameter were associated with instability.ConclusionIdentified risk factors varied depending on the cause for revision. Although septic revisions were related to patient characteristics, more modifiable factors, such as implant or surgical approach, were associated with revision due to aseptic loosening and instability.Level of EvidenceIII.  相似文献   

6.
BackgroundHemochromatosis can result in metabolic bone pathology (due to excessive iron absorption) and degenerative joint disease, leading to total joint arthroplasties. The aim of this study is to analyze the survivorship, complications, radiographic results, and clinical outcomes of patients with hemochromatosis who received either a total hip arthroplasty (THA) or a total knee arthroplasty (TKA).MethodsWe identified 34 lower extremity arthroplasties in 29 patients with hemochromatosis performed between 2000 and 2016. There were 17 primary THAs in 15 patients and 17 primary TKAs in 14 patients. Mean age at arthroplasty was 63 years with 76% being male. The mean body mass index was 28 kg/m2. Mean follow-up was 5 years.ResultsThe survivorship free from any revision for THAs was 94% at 10 years. One patient was revised for aseptic loosening of the femoral stem at 6 months. In THA patients, no infections, no other complications, and no radiographic evidence of aseptic loosening were identified. Harris Hip Scores improved from a mean of 55 preoperatively to 94 postoperatively (P < .001). The survivorship free from any revision for TKAs was 100% at 10 years. Two patients (12%) developed acquired idiopathic stiffness postoperatively; no infections were identified. There was no radiographic evidence of aseptic loosening in any TKA. Knee Society Scores improved from a mean of 61 preoperatively to 94 postoperatively (P < .001).ConclusionThis study found excellent survivorship, significant improvements in clinical outcomes, and a very low complication profile for both THA and TKA in patients with hemochromatosis.  相似文献   

7.
《The Journal of arthroplasty》2020,35(4):1130-1136
BackgroundThe aim of this meta-analysis and systematic review is to estimate re-revision rates due to aseptic loosening of retained acetabular components after revision total hip arthroplasty.MethodsPubMed, EMBASE, Cochrane Library, and Web of Science were searched until June 11, 2018. Data were extracted by 2 independent investigators and consensus was reached with the involvement of a third investigator. Rates of re-revision due to aseptic loosening from 6 studies were aggregated using random effects model after a logit transformation and were grouped by study and population level characteristics.ResultsAn assessment of the re-revision rates of retained acetabular components due to aseptic loosening in revision total hip arthroplasty was reported in 6 studies involving 669 cases. The pooled re-revision rate was 12.6% (95% confidence interval 8.4-18.4) with a mean study follow-up of 8.6 years. The rate of re-revision due to aseptic loosening of retained acetabular components was 6.8% (95% confidence interval 3.4-13.3). In the univariate meta-regression analysis, mean age at index revision surgery was significantly associated with the rate of re-revision due to aseptic loosening (R2 = 99.98%, P < .0001).ConclusionBased on this exploratory analysis, revision hip procedures with retentions of well-fixed acetabular components generally have a low risk of failure during mid-term to long-term follow-ups.  相似文献   

8.
BackgroundWe sought to evaluate the risk of aseptic revision in total knee arthroplasty (TKA) patients who have and do not have a history of primary or revision arthroplasty of a different major joint.MethodsWe conducted a matched cohort study using data from Kaiser Permanente’s arthroplasty registries. Patients who underwent primary unilateral TKA (index knee) were identified (2009-2018). Two matches based on exposure history were performed: (1) 33,714 TKAs with a history of primary arthroplasty of a different joint (contralateral knee, either hip, and/or either shoulder) were matched to 67,121 TKAs without an arthroplasty history and (2) 597 TKAs with a history of aseptic revision in a different joint were matched to 1,190 TKAs with a history of a prior arthroplasty in a different joint, but without any revision. After the matches were performed, Cox regressions were used to evaluate aseptic revision risk of the index knee using the no history groups as the reference in regression models.ResultsNo difference in aseptic revision risk for the index knee was observed when comparing patients who had a prior primary arthroplasty in a different joint to those who did not have an arthroplasty history (hazard ratio = 0.95, 95% CI = 0.86-1.06). Those patients who did not have any prior aseptic revision history in a different joint had higher risk of aseptic revision in the index knee (hazard ratio = 2.06, 95% CI = 1.17-3.63).ConclusionPatients who had a prior revision history had over a 2-fold higher risk of aseptic revision in the index knee, warranting close surveillance of these patients.Level of EvidenceLevel III.  相似文献   

9.
《The Journal of arthroplasty》2023,38(5):855-861.e1
BackgroundCementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort.MethodsData from an integrated healthcare network’s total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons.ResultsAfter adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons.ConclusionsType 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant.Level of EvidenceLevel III.  相似文献   

10.
《The Journal of arthroplasty》2021,36(9):3233-3240
BackgroundDual mobility (DM) and large femoral head bearings (≥36 mm) both decrease the risk of dislocation in total hip arthroplasty (THA). There is limited comparable data in primary THA. This study compared the revision rates for dislocation and aseptic causes between DM and large femoral heads and subanalyzed by acetabular component size.MethodsData from the Australian Orthopedic Association National Joint Replacement Registry were analyzed for patients undergoing primary THA for osteoarthritis from January 2008 (the year of first recorded DM use) to December 2019. All DM and large femoral head bearings were identified. The primary outcome measure was the cumulative percent revision (CPR) for dislocation and for all aseptic causes. The results were adjusted by age, sex, and femoral fixation. A subanalysis was performed stratifying acetabular component diameter <58 m and ≥58 mm.ResultsThere were 4942 DM and 101,221 large femoral head bearings recorded. There was no difference in the CPR for dislocation (HR = 0.69 (95% CI 0.42, 1.13), P = .138) or aseptic causes (HR = 0.91 (95% CI 0.70, 1.18), P = .457). When stratified by acetabular component size, DM reduced the CPR for dislocation in acetabular component diameter <58 mm (HR = 0.55 (95% CI 0.30, 1.00), P = .049). There was no difference for diameter ≥58 mm. There was no difference in aseptic revision when stratified by acetabular component diameter.ConclusionThere is no difference in revision rates for dislocation or aseptic causes between DM and large femoral heads in primary THA. When stratified by acetabular component size, DM reduces dislocation for acetabular component diameter <58 mm.Level of EvidenceLevel III.  相似文献   

11.
《The Journal of arthroplasty》2022,37(5):897-904.e1
BackgroundTotal hip arthroplasty (THA) for avascular necrosis (AVN) or inflammatory arthritis (IA) comes with a relatively high risk of aseptic stem loosening, especially in young patients. There are limited long-term data on the survivorship of polished, tapered, cemented stems in this population. We therefore performed a single-center retrospective study investigating the survival of this particular stem type in young patients with AVN or IA.MethodsAll patients aged ≤35 years who had received a THA for AVN or IA operated on by the senior author between 1990 and 2010 at the University Hospitals Leuven were identified. In total, 85 THAs in 62 patients were included. Primary endpoint was revision of the femoral component for aseptic loosening. Secondary endpoints were revision of the acetabular component for aseptic loosening, revision for other reasons, and the presence of radiolucencies around the components.ResultsThe mean follow-up for the entire cohort was 18.0 ± 5.3 years (range 8.0-28.9). Taking revision for aseptic loosening as endpoint, the survival of cemented stems was 100% after 15 years and 95.1% after 20 years. Survival of uncemented cups (91.3%) was significantly better than survival of cemented cups (50.3%) after 20 years of follow-up for aseptic loosening. Taking revision for any reason as endpoint, the survival of THAs with uncemented and cemented cups was 90% and 43.1% at 20 years respectively. Radiolucencies developed in the cement mantles around 11 of the 81 nonrevised stems, mainly in zones 1 and 7.ConclusionIn this cohort of young patients with high-risk profiles for aseptic stem loosening, polished, tapered, cemented stems showed excellent long-term survival rates and they therefore remain a viable alternative to uncemented stem designs.  相似文献   

12.
《The Journal of arthroplasty》2020,35(6):1737-1749
BackgroundA number of papers have been published reporting on the clinical performance of highly porous coated titanium acetabular cups in primary and revision total hip arthroplasty (THA). However, no systematic review of the literature has been published to date.MethodsThe US National Library of Medicine (PubMed/MEDLINE), Embase, and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: “tritanium” OR “highly-porous” AND “titanium” OR “acetabular” AND “trabecular” AND “titanium”.ResultsOverall, 16 studies were included in this review (11,366 cases; 60% females, 2-7 years mean follow-up). The overall survival rate of highly porous titanium acetabular components in primary cases was 99.3% (10,811 of 10,886 cases), whereas the rate of aseptic loosening was 0.1%. The overall survival rate of the highly porous titanium acetabular components in revision THA cases was 93.5% (449 of 480 cases), whereas the rate of aseptic loosening was 2.1%.ConclusionThere was moderate quality evidence to show that the use of highly porous titanium acetabular components in primary and revision THA cases is associated with satisfactory clinical outcomes in the short- and medium-term, without showing any evidence of cup migration or radiolucency. Taking into consideration that there is no evidence yet regarding the long-term survivorship of these components, we feel that further research of higher quality is required to generate more evidence-based conclusions regarding the longevity of highly porous titanium acetabular implants compared with conventional titanium counterparts.  相似文献   

13.
《The Journal of arthroplasty》2022,37(11):2308-2315.e2
BackgroundHighly cross-linked polyethylene (HXLPE) liners have been developed to address the wear-related problems associated with conventional polyethylene (CPE) such as osteolysis or aseptic loosening in total hip arthroplasty (THA). In this systematic meta-analysis, we compared the long-term efficacy in preventing radiological osteolysis and revision surgery between HXLPE and CPE.MethodsWe included 14 studies that compared HXLPE and CPE reporting the incidence of wear-related complications with a minimum follow-up of 10 years. We investigated 5 wear-related complications: osteolysis, excessive wear, linear wear rate, revision surgery due to wear, and progress of osteolysis/aseptic loosening. We conducted a pair-wise meta-analysis to estimate odds ratio (OR) and a proportional meta-analysis to estimate the incidence of each complication.ResultsAmong 1,175 THAs, 220 osteolysis and 78 wear-related revisions were detected. The use of HXLPE reduced the risk of overall osteolysis (OR 0.30; P = .001), excessive wear (OR 0.10; P < .001), linear wear rate (weighted mean difference 0.09; P < .001), the risk of overall wear-related revisions (OR 0.06; P < .001), and revisions due to aseptic loosening (OR 0.23; P = .015). As per the proportional meta-analysis, the pooled prevalence of osteolysis, excessive wear, and the overall wear-related revision rate were 14%, 8%, and 3% in HXLPE and 25%, 33%, and 20% in CPE, respectively.ConclusionThe current evidence shows that HXLPE dramatically reduced the rate of osteolysis and wear-related revision surgery. However, as polyethylene wear and osteolysis still lead to revision surgery, ongoing clinical and retrieval studies are required to analyze long-term outcomes.  相似文献   

14.
《The Journal of arthroplasty》2020,35(5):1412-1416
BackgroundIn cases of total hip arthroplasty (THA) dislocation, a synovial fluid aspiration is often performed to evaluate for periprosthetic joint infection (PJI). It is currently unclear how aseptic dislocation of a THA influences synovial fluid white blood cell (WBC) count and polymorphonuclear percentage (PMN%). The primary aim of this study is to investigate the influence of THA dislocation on synovial WBC count and PMN%.MethodsTwenty-eight patients who underwent a synovial aspiration of a THA between 2014 and 2019 were identified and enrolled in our case-control study. Patients with an aseptic THA dislocation and synovial hip aspiration were matched against patients without dislocation, patients undergoing hip aspiration before aseptic THA revision surgery, and patients undergoing hip aspiration before septic THA revision surgery.ResultsSynovial WBC count was significantly increased in the dislocation vs aseptic THA revision group (P = .015), as well as between the septic revision group vs dislocation and aseptic THA revision group (both P < .001). The PMN% did not differ significantly between the dislocation and aseptic revision groups (P = .294). Mean C-reactive protein values were 12.4 ± 14.9 mg/dL in THA dislocation, 24.1 ± 37.7 mg/dL in THA without infection compared to 85.7 ± 84.9 mg/dL in THA infection group (P < .001).ConclusionThis study shows that THA dislocation has a significant impact on synovial WBC count in joint aspiration. Our data suggest that in the setting of THA dislocation, synovial WBC and PMN% may not be the best method to evaluate for PJI. Further research should be performed to establish new thresholds for these synovial inflammatory markers in the setting of THA dislocation and PJI.Level of evidenceLevel III; retrospective trial.  相似文献   

15.
《The Journal of arthroplasty》2023,38(2):209-214.e1
BackgroundIt is unclear how epilepsy may affect total joint arthroplasty outcomes. The purpose of this study is to analyze the impact of epilepsy on prosthesis-related complications following primary total hip arthroplasty (THA) and total knee arthroplasty (TKA).MethodsA retrospective cohort study was conducted using a national database. Patients who have epilepsy underwent a primary THA (n = 6,981) and TKA (n = 4,987) and were matched 1:4 (THA, n = 27,924; TKA, n = 19,948). Rates of low-energy falls and prosthesis-related complications within 2 years postoperatively were compared for patients who did and did not have epilepsy with multivariable logistic regression.ResultsAfter primary TKA, patients who have epilepsy exhibited significantly higher rates of aseptic revision (4.3% versus 3.5%, odds ratio [OR] 1.21, P = .017) and revision for prosthetic joint infection (1.8% versus 1.3%, OR 1.29, P = .041). THA patients who have epilepsy exhibited significantly higher rates of prosthetic dislocation (3.2% versus 1.9%, OR 1.54, P < .001), periprosthetic fracture (2.2% versus 0.8%, OR 2.39, P < .001), and aseptic loosening (1.7% versus 1.1%, OR 1.40, P = .002). Rates of low-energy falls within 2 years after TKA (14.1% versus 6.4%, OR 2.19, P < .001) and THA (33.6% versus 7.5%, OR 5.95, P < .001) were also significantly higher for patients who have epilepsy.ConclusionEpilepsy was associated with significantly higher rates of falls (P < .001) and prosthesis-related complications after primary THA (P < .05) and TKA (P < .05). Precautions should be implemented in this population during intraoperative and perioperative decision-making to reduce complication risk.Level of EvidenceLevel III.  相似文献   

16.
《The Journal of arthroplasty》2022,37(8):1658-1666
BackgroundTo date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for clinical and functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether minimally invasive approaches are superior to conventional approaches for clinical outcomes.MethodsAll studies comparing MI approaches to conventional approaches were eligible for analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: ‘minimally invasive’, ‘muscle-sparing’, ‘THA’, ‘THR’, ‘hip arthroplasty’ and ‘hip replacement’. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the European Union (EU) clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation).ResultsTwenty studies were identified. There were 1,282 MI total hip arthroplasty (THAs) and 1,351 conventional THAs performed. There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (P = .959), aseptic revision (P = .894), instability (P = .894), infection (P = .669) and periprosthetic fracture (P = .940). There was also no difference in functional outcome at early or intermediate follow-up between the two groups (P = .38). In level I studies exclusively, random-effects meta-analysis demonstrated no difference in aseptic revision (P = .461) and all other outcomes between both groups.ConclusionIntermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.  相似文献   

17.
《The Journal of arthroplasty》2020,35(12):3638-3643
BackgroundControversy exists whether previous pelvic osteotomies have negative effects on total hip arthroplasty (THA). This study evaluates the implant survival and patient-reported outcomes of THA after previous Chiari pelvic osteotomy (CPO).MethodsData on 301 THAs after CPO were collected through clinical and radiological follow-up examinations and telephone interviews. The Kaplan-Meier survivorship analysis depicts implant survival.ResultsOf this consecutive series of 1536 CPOs, follow-up was completed in 405 patients with 504 CPOs after a mean time of 36 years (±8; range, 22-54 years). At follow-up, 301 hips (60%) had already undergone THA. The overall survival of THA with revision as an end point after 10, 20, and 25 years was 93%, 76%, and 68%, respectively. The revision rate was 12%. The average period between THA and revision surgery was 9.6 years (±6.1; 4 months-25.4 years). The patient’s age at revision was 57.9 years (±10; 33.2-78.5 years). Aseptic loosening was the most common of the known reasons for revision surgery.ConclusionThis retrospective study supports the hypothesis that prior CPO does not compromise the prerequisites for successful THA at a later stage. Survival rates of the implanted prosthesis are comparable to primary implanted hips, as overall survival was 93% after 10 years.  相似文献   

18.
《The Journal of arthroplasty》2019,34(7):1435-1440
BackgroundThe purpose of this study was to identify reasons for revision of total hip arthroplasty (THA) in patients who underwent primary THA at or before the age of 35 years. We hypothesized that the reasons for revision in younger patients would be different from the general older population of patients undergoing THA because of the differences in diagnoses, complexity of deformities, and differences in activity level.MethodsData for 108 hips in 82 patients who underwent primary THA at our institution before the age of 35 years from 1982-2007 and subsequently underwent revision THA were reviewed. Operative reports and clinic notes were reviewed to determine baseline characteristics, reason for revision, timing of revision, and components revised.ResultsThe mean age at index surgery was 25.4 years, and mean time from index to revision surgery was 10.1 years. The most common preoperative diagnoses included avascular necrosis, juvenile idiopathic arthritis, developmental dysplasia of the hip, and posttraumatic arthritis. The most common reasons for revision were acetabular loosening (30.1%), femoral loosening (23.7%), and polyethylene wear (24.7%). 8.3% of patients underwent primary THA with highly cross-linked polyethylene, while the remainder of the patients underwent THA when conventional polyethylene was used. There was no statistically significant association between which component(s) were revised and initial fixation (ie cemented or uncemented prosthesis) (P = .26).ConclusionCauses of revision in this population appear to differ from the general THA population. In young patients, acetabular loosening, femur loosening, and polyethylene wear were the most common causes of revision. Instability and infection were less common compared with literature reports of causes of revision in older patients. Findings in this study may be useful in counseling young patients undergoing THA, though results were likely influenced by the use of conventional rather than highly cross-linked polyethylene in this cohort.  相似文献   

19.
《The Journal of arthroplasty》2023,38(9):1802-1807
BackgroundPrevious studies have reported excellent results with tapered, titanium, porous plasma-sprayed components in patients undergoing uncemented primary total hip arthroplasty (THA). The purpose of this study was to examine survival and clinical results at a minimum 25-year follow-up.MethodsWe reviewed all patients who underwent primary THA at our center through 1995 with a specific femoral component that was essentially unchanged since its 1984 introduction, except porous coating was continued circumferentially in 1987, a hydroxyapatite-coated option was offered in 1988, and an offset option was added in 1999. There were 332 patients (396 THA) who had a minimum 25-year follow-up (range, 25 to 37). Mean age at surgery was 48 years (range, 21 to 70 years). Mean follow-up in nonfailed patients was 29 years (range, 25 to 37 years).ResultsThere were 31 femoral revisions (7.8%): 9 infections, 3 failures of ingrowth, 5 aseptic loosening, 8 osteolysis well-fixed, 2 periprosthetic fractures, 2 polyethylene wear with trochanteric avulsion, 1 component breakage, and 1 malalignment well-fixed. Kaplan-Meier survival with the endpoint of all-cause stem revision was 94.8% (95% confidence interval: ±0.9%) at 37 years, and with the endpoint of aseptic loosening/failure of ingrowth was 98.7% (95% confidence interval: ±0.5) at 37 years. Harris hip scores improved significantly from 43 preoperatively to 76 most recently.ConclusionThis tapered, titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of femoral component revision for any reason or aseptic loosening/failure of ingrowth.  相似文献   

20.
BackgroundIt is often challenging to decide whether to revise only the bearing or femoral acetabular component in the setting of progressive osteolysis without component loosening in revision total hip arthroplasty (THA). In this study, we aimed to (1) compare the survivorship of isolated bearing exchange and single/both component revision for patients with periprosthetic osteolysis without component loosening, and (2) identify potential risk factors associated with failures of isolated bearing exchange.MethodsA total of 228 consecutive cases of revision THA for progressive osteolysis without component loosening was evaluated in 2 groups: (1) 124 component revision and (2) 104 isolated bearing exchange. The primary outcome was survival, with failure defined as repeat revision or reoperation for any reason. Patient risk factors, such as demographics and medical comorbidities, were also analyzed.ResultsThere was no significant difference in survivorship between the component revision group and the bearing exchange group at 10 years (85% vs 82%; P = .89). There was no progression of osteolysis on radiographs at last follow-up for patients with isolated bearing change. Univariate regression modeling demonstrated that renal disease was associated with failure of isolated bearing exchange after revision THA.ConclusionThis study demonstrated that isolated bearing exchange is associated with similar outcomes compared with component revision for aseptic osteolysis without loosening, demonstrating that isolated bearing exchange is a viable option for selected patients with osteolysis in the setting of well-fixed THA components. This provides clinically useful information for surgeons in the surgical treatment of THA patients with wear and osteolysis without component loosening.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号