首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundBearing dislocation is a serious complication of unicompartmental knee arthroplasty (UKA) with the Oxford knee prosthesis equipped with a mobile bearing. We aimed to clarify the extent of intraoperative movement of the mobile bearing and its relationship with the positioning of prosthesis components in patients undergoing Oxford UKA.MethodsThis retrospective study included 50 patients (50 knees) who underwent Oxford UKA for anteromedial osteoarthritis or osteonecrosis of the knee. Intraoperative bearing movement was assessed at various angles of knee flexion (0°, 30°, 60°, 90°, and 120°). We stratified patients according to the extent of bearing movement posteriorly during intraoperative knee flexion, with or without contacting the lateral wall of the tibial component (with contact, 20 knees; without contact, 30 knees). Postoperative radiographic evaluations were conducted at 1 week postoperatively to assess the positional parameters of the tibial and femoral components (varus/valgus alignment, rotation, mediolateral position). Clinical evaluations were conducted at 1 year postoperatively (maximum flexion angle, Oxford Knee Score).ResultsAbnormal intraoperative movement of the mobile bearing resulting in contact with the lateral wall of the tibial component was associated with a significantly more medial position and external rotation of the tibial component, as well as poorer improvement in knee flexion angle at 1 year postoperatively.ConclusionIn Oxford UKA recipients, the bearing may impinge on the lateral wall of the tibial component during flexion above 60° if the tibial component is placed too medially or exhibits pronounced external rotation, which may limit knee function improvement postoperatively.  相似文献   

2.
BackgroundIt is widely known that the posterior tibial slope (PTS) has an influence on the clinical outcome of arthroplasty. However, the influence of PTS on unicompartmental knee arthroplasty (UKA) is still not fully clear. The objective of this study is to reveal the effect PTS has on knee flexion and extension joint gap and the postoperative range of motion in mobile-bearing UKA. Moreover, we investigated an adequate PTS angle in mobile-bearing UKA.MethodsOxford UKA was performed so that the flexion gap would be equal to the extension gap. Correlation between the gap value difference from 90° to 120° of the knee flexion and the PTS was evaluated. Correlation between postoperative range of motion and the PTS was also evaluated to find whether a small degree of PTS would cause knee flexion restriction.ResultsThe PTS had a moderate positive correlation with the flexion gap difference. However, the PTS had no correlation with the knee flexion angle both postoperative and 1 year after surgery.ConclusionIt was suggested that the degree of the PTS should not be so large to avoid joint looseness throughout every knee angle. Increasing the degree of the PTS had the potential to dislocate the bearing. Since a small degree of the PTS does not have an influence on the clinical outcome, surgeons should aim to cut the tibia with a posterior slope of less than 7°.  相似文献   

3.
Unicompartmental knee arthroplasty (UKA) is widely performed in the United Kingdom for the management of patients with symptomatic osteoarthritis of the medial compartment of the tibiofemoral joint. A limited number of papers have presented the findings of mid-term clinical and survival data with sufficiently large patient numbers following mobile-bearing UKA. The purpose of this study was to present the 6- to 8-year follow-up data on a series of 230 minimally invasive medial Oxford Phase 3 mobile-bearing UKAs in our institution. Data on surgical procedure, postoperative rehabilitation requirement, complications, revision procedures and Oxford Knee Score (OKS), Short Form-12 (SF-12) and visual analogue scale (VAS) pain scores were analysed. The results indicated that the majority of patient’s recoveries were uneventful, with 96% experiencing no postoperative complications. The mean OKS, VAS pain and SF-12 scores indicated good functional outcomes and acceptable perceived general health for this age group. Twenty-one patients underwent revision surgery, indicating a survival rate of 85% (95% CI: 0.76–0.91) during the 6- to 8-year follow-up period. The most frequently cited indication for revision was due to progression of osteoarthritis to the lateral component. To conclude, this series indicated that the mobile-bearing Oxford UKA provides good clinical outcomes at 6- to 8-year follow-up, with minimal requirement for postoperative rehabilitation, few complications and an acceptable survivorship in the mid-term.  相似文献   

4.
《The Journal of arthroplasty》2023,38(7):1251-1256
BackgroundPrecise indications for medial unicondylar knee arthroplasty (UKA) continue to be defined. It is unclear if patients who have proximal tibia vara should be considered candidates for UKA. The purpose of this study was to evaluate the impact of proximal tibial varus alignment on outcomes after UKA.MethodsA retrospective review identified 2,416 patients (3,029 knees) who underwent mobile-bearing medial UKA with 2-year minimum follow-up or revision. Preoperative radiographs were evaluated, and medial proximal tibial angle (mPTA) was measured. Patients were grouped into two groups as follows: mPTA <80 degrees and mPTA ≥80 degrees. Analyses were performed on the impact of mPTA on clinical outcomes, all-cause revisions, and tibial failures.ResultsAt a mean follow-up of 5 years (range, 0.5 years to 12.8 years), there was not a statistically significant difference in clinical outcomes nor increased risk for all-cause revision or tibial failure in patients who had an mPTA <80°. Mean mPTA in patients who had tibial failures was 82.5° and not significantly different than those who did not have a tibial failure (82.9°) (P = .289). Tibial failure rate in knees with an mPTA <80° was 2.2% and not significantly different than knees with an mPTA ≥80° at 1.4% (P = .211). The all-cause revision rate in knees with an mPTA <80° was 5.8% and was not significantly different than knees with an mPTA ≥80° at 4.9% (P = .492).ConclusionPatients who have tibia vara are not at increased risk for tibial related or all-cause failure in medial UKA. This data may allow surgeons to increase their indications for medial UKA.  相似文献   

5.
《The Journal of arthroplasty》2020,35(11):3108-3116
BackgroundThe direct relationship between clinical outcomes and femoral component positioning relative to a tibial insert remains unknown. We determined whether the femoral component position relative to the tibial insert could affect clinical outcomes after fixed-bearing unicompartmental knee arthroplasty (UKA).MethodsThe femoral component position relative to the tibial insert of 66 patients with anteromedial osteoarthritis and osteonecrosis of the knee who underwent fixed-bearing UKA was assessed at 2 weeks postoperatively. We classified patients according to the contact point of the femoral component with the tibial component: group M (medial), 18 knees; group C (central), 30 knees; and group L (lateral), 18 knees. Patient-derived clinical scores using the 2011 Knee Society Score were also assessed preoperatively and at 2 years postoperatively and compared among the 3 groups using the analysis of variance.ResultsThe average 2-year postoperative “symptom” and “patient satisfaction” scores based on the 2011 Knee Society Score were significantly higher in group C than in group M or group L.ConclusionCentral implantation of the femoral component relative to the tibial insert plays an important role in decreasing pain and could result in better patient satisfaction after fixed-bearing UKA at 2 years postoperatively. Surgeons should set the femoral component at the center relative to the tibial insert for better patient satisfaction and higher active knee flexion after fixed-bearing UKA.  相似文献   

6.
BackgroundThe posterior tibial slope (PTS) is an important factor in patients undergoing unicondylar knee arthroplasty. It is an area subjected to high shear and compressive forces. Our objective is to investigate the changes taking place on the tibial slope of cementless unicondylar knee arthroplasties and define its relationship with functional scores.MethodsPatients undergoing a cementless unicondylar knee arthroplasty between January 2011 and July 2019 were selected. Exclusion criteria were lack of at least 1 year of follow up, loss to follow-up for any reason, and revision of a metallic component. Overall, 161 cases were included. Patients were analyzed using standard radiographs for changes in PTS, coronal positioning of the implant, and overhanging. Function was analyzed using Oxford Knee Score, Tegner Activity Scale, and Knee Society Score. Changes of the PTS were analyzed for statistical significance and for correlations with all the other variables.ResultsAll postoperative functional scores showed significant improvement (P < .05). Compared to the early postoperative values, increases of ≤5° were detected in 79% of all patients. The greater amount of slope change occurred during the first 6 months postoperatively. Statistical analysis revealed no significant relationship with functional scores of the knee, age, body mass index, overhanging, and coronal alignment of the tibial component.ConclusionThis study showed that, with time, minimal changes take place in the PTS of cementless unicondylar knee arthroplasty. The change mostly takes place during the first 6 months. These changes do not affect functional scores.  相似文献   

7.
BackgroundThe main purpose of the present study was to analyze the clinical and radiological outcomes of patients with positive skin patch tests who underwent medial mobile-bearing titanium niobium nitride unicompartmental knee arthroplasty (UKA) during a mid-term follow-up.MethodsThirty-seven patients with positive skin patch tests were included in this prospective study. The clinical evaluation consisted of Oxford Knee Score and Knee Society Score (KSS) reports. Each patient was clinically evaluated the day before surgery (T0) as well as at T1 (11.9 ± 1.3 months) and during the final follow-up T2 (67.2 ± 19.1 months). The positioning of the UKA was evaluated during the final follow-up using standardized radiographs (T2: 67.2 ± 19.1 months).ResultsOxford and KSS ranged from a respective mean preoperative value of 23.0 ± 2.7 and 51.5 ± 5.0 to 42.1 ± 1.7 and 87.6 ± 2.2, respectively, at T1 (P < .001) and to the final values of 45.0 ± 1.9 and 91.9 ± 3.4, respectively, at T2 (P < .001 both vs T1 and T2). At T2, the mean femoral angle was 7.0° ± 4.5°, mean tibial angle was 3.0° ± 2.1°, and mean tibial slope was 5.1° ± 3.2°. A significant difference was found between KSS and Oxford with ANOVA for repeated measures over time (P < .001). The Oxford and KSS scores showed significant improvements during each follow-up. No complications were found, and not a single patient required a revision surgery during the follow-up period.ConclusionThe hypoallergenic titanium niobium nitride mobile-bearing UKA showed comparable results to standard CoCr UKA regardless of the gender, age, BMI, and implant size of metal allergy patients with medial knee osteoarthritis. Careful patient selection processes and accurate medical histories played key roles in the choice of hypersensitivity-friendly implants.  相似文献   

8.
BackgroundAn intact anterior cruciate ligament (ACL) is thought to be prerequisite for successful unicompartmental knee arthroplasty (UKA), but recent studies reported successful midterm results of UKA in ACL-deficient (ACLD) knees. We hypothesized that ACLD is not always a contraindication for medial UKA when preoperative radiographs showed typical anteromedial knee patterns.MethodsFrom April 2012 to March 2016, 401 Oxford mobile-bearing UKAs in 282 patients were retrospectively identified from our database. Patients whose ACL was severely damaged, but preoperative X-rays showed typical anteromedial osteoarthritis patterns, were categorized into the ACLD group. From intraoperative data, those whose ACL was intact were categorized into the ACL functional (ACLF) group. There were 32 and 369 knees in the ACLD and ACLF groups, respectively, and mean follow-up periods were 66.1 and 63.8 months for the ACLD and ACLF groups, respectively. We compared the postoperative clinical outcome and component survivorship, with an endpoint of component revision, between ACLD groups and ACLF groups.ResultsIn both groups, the Oxford knee score, Knee Society score, Tegner activity score, and knee range of motion in extension were improved after surgery. The UKA component survival rate at five years was 100% in the ACLD group and 98.9% in the ACLF group. There were no significant differences between the groups.ConclusionMid-term clinical outcomes of Oxford mobile-bearing UKA in ACLD knees were similar to those in ACLF knees. ACL deficiency is not always a contraindication for medial unicompartmental knee arthroplasty in patients with typical anteromedial osteoarthritis radiographs.  相似文献   

9.
BackgroundBone quality and other preoperative predictive factors may affect implant migration and the survival of knee arthroplasty.MethodsIn a prospective cohort of 100 consecutive patients (65 women) at a mean age of 67.7 years (range 39-87 years), we investigated preoperative predictors of postoperative tibial component migration in cemented and cementless total knee arthroplasties or cemented unicompartmental knee arthroplasty. Predictors consisted of Knee Injury and Osteoarthritis Outcome Score (KOOS) and Oxford Knee Score, questionnaires, bone turnover markers of CTX and P1NP, systemic bone mineral density (BMD), and knee osteoarthritis (OA) grade. Tibial component migration was measured with radiostereometry postoperative, at 1 and 2 years of follow-up.ResultsBetween 1 and 2 years, 19 tibial components migrated continuously (maximum total point motion [MTPM] > 0.2 mm). In general, there was no difference in age, body mass index, BMD, KOOSs, or OA grade between patients with continuous tibial migration compared to patients without continuous migration (P > .11). However, cementless tibial components with continuous migration had a lower KOOS pain score (more pain), lower vitamin D, and a higher bone turnover (CTX) value than patients without continuous migration. There was no association between the BMD and MTPM at 1-year follow-up regardless of prothesis type (P > .17). Patients with osteoporosis and normal BMD had similar mean tibial component MTPM at 2 years (3 prostheses combined; P = .34).ConclusionMigration of tibial components inserted with or without bone cement was not affected by the preoperative bone quality in terms of systemic BMD, bone turnover markers, and OA grade in the knee.  相似文献   

10.
ObjectiveUnicompartmental knee arthroplasty (UKA) has indicated a higher rate of revision than total knee arthroplasty (TKA). The success of UKA depends on UKA component alignment, fixation, and soft tissue integrity. The purpose of this study was to investigate the effects of different tibial component alignments in the coronal plane on the stress distribution in UKA. It was hypothesized that the stress distribution would approach native knee when the tibial component was neutrally positioned.MethodsThe left legs from two healthy volunteers were considered to represent the geometric native knee models. All bones within the knee joint were extracted from the three‐dimensional (3D) computed tomography (CT). MRI was used to generate cartilage, menisci, and four major ligaments. The UKA components were virtually implanted in the medial compartment of the knee model using MIMICS. A total of five different configurations of UKA tibial obliquity in the coronal plane (neutral, 3° varus, 6° varus, 3° valgus, and 6° valgus) were adopted and investigated. Subject‐specific inhomogeneous material properties of bones were used in the finite element analysis (FEA) model. The von Mises stress in the tibia platform and proximal tibia, and the load distribution between the medial and lateral compartments were extracted and compared among the five different configurations.ResultsThe inhomogeneous material properties of the trabecular bone were closer to real physics than traditional homogeneous methods. Neutral and 3° varus alignments of the tibial component in the coronal plane have better stress distribution between medial and lateral compartment as healthy knee models, and less stress‐shielding effects than other UKA configurations. The stress pathway under the medial tibia platform in neutral and 3° varus UKA configurations was similar and more obvious than the other three UKA configurations. Notably, the stress of the medial tibia platform in the 3° varus UKA models was more homogenous than the neutral UKA configuration. The 6° varus, 3° valgus, and 6° valgus UKA models had higher stress at the location of anterolateral and posterolateral tibia platform than other UKA configurations.ConclusionNeutral or 3° varus positioned in the coronal plane for the tibial component could be the optimal alignment for UKA. Excessive varus or valgus obliquity in the coronal plane lead to significant differences in bone stress transfer and load distribution in the knee, and increase the risk of UKA failure.  相似文献   

11.
BackgroundA tibial plateau fracture is one of the most challenging fractures for both knee and trauma surgeons because of the high incidence of post-traumatic knee osteoarthritis. To our knowledge, there has been no study concerning the clinical outcomes after surgery in patients with non-union of complex intra-articular tibial plateau fractures. Thus, the present study aimed to assess and report the clinical outcomes in them.MethodsThe study included four patients with non-union of complex tibial plateau fractures who underwent failed initial fixation treatment or could not undergo initial fixation owing to concomitant injury and who were followed up with a diagnosis of non-union for a minimum of 6 months. At the latest follow-up, patient-reported outcome measures, including the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford 12-item Knee Score (OKS), were assessed. Additionally, the knee range of motion (ROM) was evaluated.ResultsThe mean duration from the initial surgery to revision surgery was 8.8 months, and the mean duration from the revision surgery to fracture union was 4.8 months. At the latest follow-up, the mean WOMAC score was 9.8 and the mean OKS was 43.5. Additionally, the mean knee ROM values were ?11 degrees of extension and 100 degrees of flexion. All four patients had become able to walk without any aid after averaged 4.5-years follow up.ConclusionFavorable clinical outcomes can be achieved following revision surgery involving open reduction and IF in patients with non-union of complex tibial plateau fractures after failed initial treatment.Level of evidenceLevel IV, Case report.  相似文献   

12.
BackgroundThe purpose of this study is to compare the micromotion of various tibial reconstruction strategies including short cemented and long cementless stems with or without metaphyseal augmentation.MethodsA moderate tibial bone defect was milled into dual density polyurethane test blocks. Mechanical testing was performed on 4 test constructs: (1) short cemented stem (75-mm total length) alone; (2) short cemented stem with a symmetric metaphyseal cone; (3) a press-fit (175-mm total length) diaphyseal engaging tibial construct without a cone, and (4) the same press-fit tibial construct with a metaphyseal cone augment. Micromotion of the baseplate/cone construct with respect to the tibia block was measured during a stair descent loading profile for 10,000 cycles. The peak-to-peak micromotion of these various tibial constructs was compared. Unpaired t-tests were used to evaluate differences in peak-to-peak micromotion among the various tibial constructs tested. An analysis of variance was performed for final validation.ResultsThe cemented short stem demonstrated similar varus/valgus displacement, internal/external rotation, compression, and lift-off micromotion values under loading compared to a cementless long stem. A tibial cone improved compression and lift-off micromotion for both cemented and cementless constructs. A short 50-mm cemented stem with a cone demonstrated a lower micromotion at the anterior SI location compared to a press-fit 150-mm cementless stem without a tibial cone.ConclusionsA short cemented tibial component with a cone achieved similar micromotion during simulated stair descent compared to a cementless diaphyseal press-fit implant in cases of moderate tibial defects  相似文献   

13.
We reviewed the revision rate and functional outcome of all patients who had a total knee arthroplasty (TKA) after an osteotomy or unicompartmental knee arthroplasty (UKA) on the New Zealand Joint Registry. We used these data to compare the results with primary TKA scores, including comparison of age-matched subgroups. There were 711 patients who had undergone TKA as salvage for a failed osteotomy with a revision rate of 1.33 per 100 component years and a mean 6-month Oxford Knee Score (OKS) of 36.9. There were 205 patients who had a failed UKA converted to TKA with a revision rate of 1.97 per 100 component years and a mean OKS of 29.1. The revision rates of TKA for both failed osteotomy and failed UKA were significantly poorer than after primary TKA (0.48 per 100 component years). The mean OKS after revision of a UKA was significantly poorer than both primary TKA and TKA for a failed osteotomy. There was no significant difference in mean OKS between primary TKA and TKA for a failed osteotomy, even among patients younger than 65 years. Revision of a failed osteotomy to a TKA has improved functional results compared with revision of a failed UKA. However, both yield poorer survivorship rates compared with primary TKA.  相似文献   

14.
《The Journal of arthroplasty》2023,38(6):1166-1171
BackgroundThere has been a recent increase in the use of cementless fixation for primary total knee arthroplasty. While the early results of contemporary cementless implants are promising, understanding the behavior of cementless tibial baseplates under loading remains an ongoing interest. The objective of this study was to identify the pattern of displacement that occurred under loading for a single cementless tibial baseplate design at one year post operation for stable and continuously migrating implants.MethodsThere were 28 subjects from a previous trial of a pegged highly porous cementless tibial baseplate evaluated. Subjects underwent supine radiostereometric exams from two weeks through one year after surgery. At one year, subjects also underwent a standing radiostereometric exam. Fictive points on the tibial baseplate model were used to relate translations to anatomical locations. Migration over time was calculated to determine if subjects displayed stable or continuous migration. The magnitude of inducible displacement between the supine and standing exams was calculated.ResultsInducible displacement patterns were similar between stable and continuously migrating tibial baseplates. Displacements were greatest in the anterior-posterior axis followed by the lateral-medial axis. Correlation of displacements between adjacent fictive points in these axes indicated an axial rotation of the baseplate occurred under loading (r2 = 0.689-0.977, P < .001). Less displacement occurred in the superior-inferior axis and correlations indicated an anterior-posterior tilt of the baseplate occurred under loading (r2 = 0.178-0.226, P = .009-.023).DiscussionFrom supine to standing position the predominant pattern of displacement for this cementless tibial baseplate was axial rotation, with some subjects also displaying an anterior-posterior tilt.  相似文献   

15.
BackgroundThe thickness of the polyethylene bearing in medial unicondylar knee arthroplasty (UKA) is determined by the depth of the tibial resection, degree of correctable deformity, and balance of the knee. The purpose of this study is to evaluate whether polyethylene thickness in medial mobile-bearing UKA impacts clinical outcomes and survivorship.MethodsA retrospective review from 2004 to 2017 identified patients who underwent a primary mobile-bearing medial UKA with 2-year minimum follow-up or revision. A total of 2305 patients (3030 knees) met inclusion criteria. Patients were divided in 2 groups: thin bearing (group 1): 3-mm or 4-mm bearing and thick bearing (group 2): ≥ 5 mm. The thin group consisted of 2640 knees (87%), whereas the thick group had 390 knees (13%). Preoperative and postoperative demographics, range of motion, Knee Society scores, complications, and reoperations were evaluated.ResultsMean follow-up was 5.2 years (range, 0.5 to 12.6). There was no significant difference between groups in postoperative range of motion or Knee Society scores (P > .05). Manipulations were performed in 1.3% of patients and not significantly different between groups. The all-cause revision rate for group 1 was 4.02% and group 2 was 4.58% (P = .6). Revision rates for tibial aseptic loosening were significantly higher in group 2 (1.8%) than those in group 1 (0.7%) (P = .04). There was no significant difference in failure rates between groups for tibial collapse or fracture, femoral aseptic loosening, arthritic progression, bearing dislocation, or other cause of revision.ConclusionThis study demonstrated that thicker bearings in medial UKA increased the risk of tibial aseptic loosening, but not all-cause failures or clinical outcomes.  相似文献   

16.

Background

Bone mineral density (BMD) in the proximal tibia decreases after TKA and is believed to be a factor in implant migration and loosening. Unicompartmental knee arthroplasty (UKA) is a less invasive procedure preserving knee compartments unaffected by degeneration. Finite element studies have suggested UKA may preserve BMD and that implants of differing stiffnesses might differentially affect BMD but these notions have not been clinically confirmed.

Questions/purposes

We therefore asked whether (1) proximal tibial BMD decreases after UKA, and (2) a cemented metal tibial component with a mobile polyethylene (PE) bearing would have greater BMD loss than a cemented PE tibial component.

Methods

We prospectively followed 48 patients who underwent 50 UKAs using one of two implants: one with a cemented metal tibial baseplate and a mobile PE insert (n = 26) and one with a cemented all-PE tibial component (n = 24). In followup we assessed pain and function (Oxford Knee Score, SF-12, The Knee Society Score©) and radiographs. BMD changes were assessed using quantitative CT osteodensitometry performed postoperatively and at 1 and 2 years after the index procedure.

Results

Mean cancellous BMD decreased 1.9% on the medial side and 1.1% on the lateral side. Mean cortical BMD was static, decreasing 0.4% on the medial side and increasing 0.5% on the lateral side. The greatest observed difference between implants for any region was 3.7%. There were no differences in pain or functional outcome scores.

Conclusions

BMD was preserved 2 years after UKA with no major differences seen between implant types.  相似文献   

17.
《Acta orthopaedica》2013,84(5):582-588
Background and purpose There is disagreement in the literature about the importance of patellofemoral joint degeneration and knee pain for the outcome of unicompartmental knee arthroplasty (UKA). We therefore investigated the importance of selected predictors including patellofemoral joint degeneration and the location of preoperative knee pain for the early outcome of UKA.

Patients and methods The study group comprised 260 consecutive patients from 5 hospitals who underwent Oxford UKA for anteromedial osteoarthritis. Data were collected at baseline and included pain location, radiologically observed degeneration of the patellofemoral joint including subluxation of the patella, intraoperative cartilage status of the patellofemoral joint, disease-specific knee status, and Oxford knee score (OKS). Outcomes were evaluated after 1 year using the OKS, global patient satisfaction, and global patient result.

Results The average OKS score at baseline was 24 (SD 7), and it was 40 (SD 8) at the 1-year follow-up. 94% of the patients claimed improvement after the operation and 90% were satisfied with the UKA. Lateral subluxation of the patella was a predictor of poor outcome, and the preoperative OKS score was also a predictor of outcome. Full-thickness cartilage loss at any location gave a similar outcome to that with a normal or near-normal joint surface, and likewise, preoperative anterior knee pain was not a predictor of outcome.

Interpretation We conclude that the good early outcome after UKA in this study is in line with the best reported results. Patellofemoral degeneration should not be considered a contraindication to Oxford UKA. Patients with lateral subluxation of the patella have an increased risk of a poor result after UKA and should preferably be offered a total knee replacement.  相似文献   

18.
PurposeThis study aimed to compare the clinical and radiographic outcomes of patients with positive patch tests undergoing a medial mobile-bearing titanium–niobium nitride (TiNbN) unicompartmental knee arthroplasty (UKA) to patients undergoing standard UKA (cobalt–chromium [CoCr] implants).MethodsTwo successive groups of patients, amounting to a total of 246 individuals, who received Oxford (Zimmer-Biomet, Warsaw, Indiana, USA) UKA were included. The first group was composed of a series of 203 consecutive standard CoCr UKAs (Standard Group), while the second group comprised 43 consecutive hypoallergenic TiNbN UKAs (HA group). The patients of the second group had a positive epicutaneous patch test result for metals. Each patient was evaluated using the Oxford Knee Score (OKS) and Knee Society Score (KSS) a day prior to the surgery (T0) and at two consecutive follow-ups, namely T1 (minimum follow-up of 12 months) and T2 (minimum follow-up of 34 months). Radiographic measurements were performed at the final follow-up (T2).ResultsNo statistical differences were noted between the two groups regarding demographic data (p > 0.05). No clinical or radiographic differences were found between the HA and standard groups at any follow-up (p > 0.05). A statistically significant improvement was found at any follow-up for both OKS and KSS (p < 0.05).ConclusionsNo clinical or radiographic differences between the hypoallergenic and standard cobalt–chromium groups at any follow-up were found, with a clinically significant improvement being experienced by both groups during the entire follow-up.Level of evidenceLevel II—comparative prospective study.Supplementary InformationThe online version contains supplementary material available at 10.1007/s43465-021-00486-3.  相似文献   

19.
目的探讨应用Oxford单髁置换术治疗55岁及以下膝内侧单间室骨关节炎患者的早期疗效。方法回顾性分析2014年1月至2016年12月在北京积水潭医院矫形骨科行Oxford活动平台单髁置换术治疗的47例(56膝)55岁及以下膝内侧单间室骨关节炎患者的病历资料。术前及末次随访记录患者的牛津大学膝关节评分(OKS)、视觉模拟评分(VAS)、膝关节活动度(ROM)及机械轴股骨胫骨角(mFTA),并分析患者术后并发症发生率及假体生存率。结果手术年龄为(52.77±2.28)岁。随访时间为(42.16±9.60)个月。ROM由术前的(114.02±5.75)°提高至术后的(120.35±8.63)°,差异有统计学意义(P<0.05)。VAS评分由术前的(6.14±0.86)分降低至术后的(1.18±1.38)分,差异有统计学意义(P<0.05)。mFTA角由术前的(7.14±2.66)°改善至术后的(4.10±2.39)°,差异有统计学意义(P<0.001),且无膝关节内翻过度矫正。OKS评分由术前的(20.04±3.88)分提高至术后的(42.07±4.58)分,差异有统计学意义(P<0.001),优良率为91.1%。5例患者术后残留持续疼痛。随访期间,未发生其他严重并发症,假体生存率为100%。结论Oxford单髁置换术可显著改善年轻膝内侧单间室骨关节炎患者的临床症状和膝关节功能,早期疗效满意。残留疼痛是Oxford单髁置换术后最常见的并发症。  相似文献   

20.
BackgroundThe aim of our retrospective case-control study is to identify risk factors associated with a persisting flexion contracture after total knee arthroplasty (TKA). This is an important clinical issue as a flexion contraction can lead to poor long-term clinical outcomes and patient satisfaction after TKA.MethodsThe study group included 120 knees treated for a varus osteoarthritic deformity of the knee using a posterior cruciate-retaining TKA. We evaluated the association between a flexion contracture >10°, 2 years after surgery, and the following potential risk factors, using logistic regression analysis: age, body height, body mass index, preoperative knee extension and hip-knee-ankle angle, and radiological parameters of component alignment, namely the femoral component medial angle, the femoral component flexion angle (FFA), the tibial component medial angle, and the posterior tibial slope.ResultsOf the 120 knees, a persisting flexion contracture >10° was identified in 33 (28%). The mean FFA in these cases was 7.3° (standard deviation, 1.4) compared to 4.2° (standard deviation, 1.2) for cases with a contracture of ≤10° (P = .034). On multivariate analysis, the FFA (odds ratio, 3.73; 95% confidence interval, 1.16-17.81; P = .034) and body height (odds ratio, 0.43; 95% confidence interval, 0.29-0.57; P = .041) were independent predictive risk factors for a residual flexion contracture >10°.ConclusionClinicians should be aware that flexed position of the femoral component, particularly in patients of short stature, is associated with increased occurrence of persistent flexion contracture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏