1.

BACKGROUND:

Drug-eluting coronary stent implantation emerged as a safe and effective therapeutic approach by preventing coronary restenosis and reducing the need for further revascularization. However, in contrast to bare metal stents, recent data suggest a unique underlying pathology, namely late coronary stent thrombosis and delayed endothelial healing.

OBJECTIVE:

To report a case of very late coronary stent thrombosis (834 days after implantation) requiring repeat urgent target-vessel revascularization. Importantly, six days before the acute coronary event, combined nonsteroidal anti-inflammatory drug therapy was initiated.

RESULTS:

Although a dual antiplatelet regimen was continuously maintained, aggregation measurements indicated only partial antiplatelet effect, which returned to the expected range when nonsteroidal anti-inflammatory drugs were omitted.

CONCLUSIONS:

The observation indicates that, even 834 days after drug-eluting stent implantation, effective combined antiplatelet therapy might be crucial in certain individuals and the possible impact of drug interactions should not be underestimated. Further efforts should focus on the challenging task of identifying patients or medical situations with prolonged, increased risk of stent thrombosis.  相似文献   

2.

Objective

The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India.

Background

Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them.

Methods

334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months.

Results

The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients.

Conclusion

In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients.  相似文献   

3.

Background

Long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain uncertain.

Objective

To investigate long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).

Methods

We performed search of MEDLINE, EMBASE, the Cochrane library, and ISI Web of Science (until February 2013) for randomized trials comparing more than 12-month efficacy or safety of DES with BMS in patients with STEMI. Pooled estimate was presented with risk ratio (RR) and its 95% confidence interval (CI) using random-effects model.

Results

Ten trials with 7,592 participants with STEMI were included. The overall results showed that there was no significant difference in the incidence of all-cause death and definite/probable stent thrombosis between DES and BMS at long-term follow-up. Patients receiving DES implantation appeared to have a lower 1-year incidence of recurrent myocardial infarction than those receiving BMS (RR = 0.75, 95% CI 0.56 to 1.00, p= 0.05). Moreover, the risk of target vessel revascularization (TVR) after receiving DES was consistently lowered during long-term observation (all p< 0.01). In subgroup analysis, the use of everolimus-eluting stents (EES) was associated with reduced risk of stent thrombosis in STEMI patients (RR = 0.37, p=0.02).

Conclusions

DES did not increase the risk of stent thrombosis in patients with STEMI compared with BMS. Moreover, the use of DES did lower long-term risk of repeat revascularization and might decrease the occurrence of reinfarction.  相似文献   

4.

Aims

The use of biodegradable-polymer drug-eluting stents has been shown to provide favorable results when compared with durable polymer drug-eluting stents and long-term follow up data have recently shown significant reductions in terms of very late stent thrombosis.Aim of the present study was to assess the safety and efficacy profile of a novel biodegradable polymer DES, the Yukon Choice Flex sirolimus-eluting stent.

Methods

We report here the one-year clinical outcomes associated with the use of the Yukon Choice Flex sirolimus-eluting stent in an all-comers patient population. The present stent represents a further refinement of the stent platform tested in the ISAR TEST 3 and 4 randomized clinical trials. A total of 778 consecutive patients undergoing implantation of this stent were enrolled in the present observational study and prospectively followed for one year.

Results

The use of the Yukon Choice Flex stent in a patient population with complex coronary lesion morphology was associated with optimal immediate angiographic results. At one year follow up the rates of death, myocardial infarction, definite stent thrombosis and ischemia-driven target lesion revascularization were respectively 2.4%, 1.9%, 0.3% and 11.3%.

Conclusions

The use of the sirolimus-eluting biodegradable polymer Yukon Choice Flex stent in an all-comers population of patients with complex coronary artery disease is associated with a favorable safety and efficacy profile up to one year follow up.  相似文献   

5.

BACKGROUND:

Drug-eluting stents (DES) have been shown to reduce repeat revascularizations compared with their bare-metal stent (BMS) platforms. Modern BMS may be associated with better angiographic results compared with the older BMS platforms. In the Basel Stent Kosten Effektivitats Trial (BASKET), target vessel revascularization after six months was nonsignificantly different between DES and BMS with clinical follow-up.

OBJECTIVES:

To evaluate angiographic results of the cobalt chromium Vision and Mini-Vision stents (Abbott Vascular, USA).

METHODS:

A total of 247 consecutive patients with 293 de novo lesions in native coronary arteries were treated with cobalt chromium Vision (n=184; stent diameter 2.75 mm to 4.0 mm) or Mini-Vision stents (n=109; stent diameter 2.0 mm to 2.5 mm), and scheduled for six months of angiographic follow-up. The primary end point was in-stent late loss after six months.

RESULTS:

Acute coronary syndromes were present in 83.4% (n=206) of patients. The preinterventional reference diameter of Vision stents was 2.70±0.34 mm and for Mini-Vision stents, it was 2.13±0.27 mm (P<0.001). Clinical and angiographic follow-up was 98.0% and 51.2%, respectively. In the Vision group, in-stent late loss was 0.64±0.67 mm and the binary rest-enosis rate was 17.9%. In the Mini-Vision group, in-stent late loss was 0.82±0.71 mm and the restenosis rate was 45.4%. No difference in occurrence of restenosis within the segments proximal or distal to the stent was observed. The restenotic pattern was predominantly focal with a short length of 7.9±4.4 mm.

CONCLUSIONS:

The use of the cobalt chromium Vision stent for the treatment of de novo lesions was associated with a low late loss and binary angiographic restenosis rate.  相似文献   

6.

Objective

The e-BioMatrix is a post marketing multicenter registry with an objective to evaluate the 2 year clinical safety and efficacy outcomes in patients treated with BioMatrix™ - Biolimus A9™ (BA9™) drug eluting stents (DES).

Background

Drug-eluting stents still have late-stage disadvantages that might be attributable to the permanent polymer. BioMatrix a new generation DES containing anti-proliferative drug Biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia.

Methods

This interim analysis consists of a total of 1189 patients with 1418 lesions treated with BioMatrix stent who entered this multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, and 12 months with an extended follow-up of 2 years. Recommended antiplatelet regimen included clopidogrel and aspirin for 12 months.

Results

The mean age was 57.6 ± 10.9 years, 81.8% were males, comorbidity index was 1.20 ± 1.33, 68% presented with acute coronary syndrome, 49% had hypertension and 40.8% had diabetes mellitus. One-year clinical follow-up was completed in 987 patients at the time of interim analysis. The incidence of MACE is 0.45 for 1544 person-year follow-up. There were only 03 cases of ST (01 late ST) reported during this time.

Conclusion

This registry demonstrates excellent one-year clinical safety and efficacy of BioMatrix stents. The 1-year result shows that BioMatrix stent may be a suitable alternative as compared to contemporary DESs which are currently available in the market for simple as well complex disease.  相似文献   

7.

Background

Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario.

Objectives

To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL).

Methods

Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis.

Results

A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008).

Conclusion

In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS.  相似文献   

8.

Background

Cardiovascular disease in Asia has reached epidemic proportions in recent years. Use of drug eluting stents in Asians has rapidly expanded with varying penetration rates across different countries. The XIENCE V® INDIA Study included ‘real world’ patients who underwent XIENCE V® stent implantation to assess short and intermediate term outcomes in Indian patients with diverse risk factors.

Objective

To evaluate 3-year clinical outcomes in a cohort of ‘real world’ Indian patients with CAD being treated with XIENCE V® Everolimus Eluting Coronary Stent System.

Methods

1000 patients were enrolled from 18 sites in India between June 2008 and March 2009. Patients were included if their index procedures were completed using only XIENCE V®. There were no clinical or angiographic exclusions. An independent Clinical Events Committee adjudicated all endpoint-related events. The primary endpoint was stent thrombosis rate annually through to 3 years as defined by the Academic Research Consortium criteria. The co-primary endpoint was the composite rate of cardiac death and myocardial infarction at 1 year.

Results

At 1-year the primary endpoint of definite/probable stent thrombosis rate was 0.51%. No additional very late stent thrombosis was reported through a 3-year follow up. The composite endpoint of cardiac death and any myocardial infarction was 1.9%, 2.7% and 3.1% at 1, 2 and 3 years respectively.

Conclusion

Despite the high risk population of coronary artery disease, the use of XIENCE V® in ''real world'' Indian patients was associated with very low clinical event rates upto three years of follow up.  相似文献   

9.
10.

Purpose

Drug-eluting stents are commonly used for percutaneous coronary intervention. Despite excellent clinical efficacy, the association between drug-eluting stents and the risk for late thrombosis remains imprecisely defined.

Methods

We performed a meta-analysis on 14 contemporary clinical trials that randomized 6675 patients to drug-eluting stents (paclitaxel or sirolimus) compared with bare metal stents. Eight of these trials have reported more than a year of clinical follow-up.

Results

The incidence of very late thrombosis (>1 year after the index procedure) was 5.0 events per 1000 drug-eluting stent patients, with no events in bare metal stent patients (risk ratio [RR] = 5.02, 95% confidence interval [CI], 1.29 to 19.52, P = .02). Among sirolimus trials, the incidence of very late thrombosis was 3.6 events per 1000 sirolimus stent patients, with no events in bare metal stent patients (RR = 3.99, 95% CI, .45 to 35.62, P = .22). The median time of late sirolimus stent thrombosis was 15.5 months, whereas with bare metal stents it was 4 months. Among paclitaxel trials, the incidence of very late thrombosis was 5.9 events per 1000 paclitaxel stent patients, with no events in bare metal stent patients (RR = 5.72, 95% CI, 1.08 to 32.45, P = .049). The median time of late paclitaxel stent thrombosis was 18 months, whereas it was 3.5 months in bare metal stent patients.

Conclusions

Although the incidence of very late stent thrombosis more than 1 year after coronary revascularization is low, drug-eluting stents appear to increase the risk for late thrombosis. Although more of this risk was seen with paclitaxel stents, it remains possible that sirolimus stents similarly increase the risk for late thrombosis compared with bare metal stents.  相似文献   

11.
Background & Objective Little is known about the relative efficacies of percutaneous coronary intervention (PCI) with drug-eluting stents (DES) and bare-metal stents (BMS) in elderly patients. The objective of this study was to evaluate the clinical outcome for geriatric patients who received either DES or BMS. Methods From January 2002 to October 2005, 199 consecutive Chinese geriatric patients (≥ 75 years old) underwent PCI with coronary DES or BMS implantation at our institution. We analyzed the major clinical end points that included all-cause mortality, cardiovascular death, myocardial infarction, target lesion revascularization (TLR), stent thrombosis, and bleeding complications. Results The three-year cumulative rates of all-cause mortality, cardiovascular death, and myocardial infarction were significantly lower in the DES group (6.3%, 3.6%, 5.4%) compared with the BMS group (16.2%, 11.5%, 14.9%; P < 0.05). No significant differences were found in the three-year cumulative rate for target lesion revascularization (6.3% vs. 4.6%, P = 0.61) or stent thrombosis (3.6% vs. 2.3%, P = 0.70). Likewise, there were no statistically significant differences in the cumulative rate for intracranial hemorrhage, or major and minor hemorrhage at three years. Conclusions DES-based PCI was associated with a significant reduction in the three-year cumulative rate of all-cause mortality, cardiovascular death, and myocardial infarction compared with BMS, without increased risk of TLR, stent thrombosis, or bleeding complications at three years in this group of Chinese geriatric patients.  相似文献   

12.

Background

Clinical in-stent restenosis (CISR) is the main limitation of coronary angioplasty with stent implantation.

Objective

Describe the clinical and angiographic characteristics of CISR and the outcomes over a minimum follow-up of 12 months after its diagnosis and treatment.

Methods

We analyzed in 110 consecutive patients with CISR the clinical presentation, angiographic characteristics, treatment and combined primary outcomes (cardiovascular death, nonfatal acute myocardial infarction [AMI]) and combined secondary (unstable angina with hospitalization, target vessel revascularization and target lesion revascularization) during a minimal follow-up of one year.

Results

Mean age was 61 ± 11 years (68.2% males). Clinical presentations included acute coronary syndrome (ACS) in 62.7% and proliferative ISR in 34.5%. CISR was treated with implantation of drug-eluting stents (DES) in 36.4%, Bare Metal Stent (BMS) in 23.6%, myocardial revascularization surgery in 18.2%, balloon angioplasty in 15.5% and clinical treatment in 6.4%. During a median follow-up of 19.7 months, the primary outcome occurred in 18 patients, including 6 (5.5%) deaths and 13 (11.8%) AMI events. Twenty-four patients presented a secondary outcome. Predictors of the primary outcome were CISR with DES (HR = 4.36 [1.44–12.85]; p = 0.009) and clinical treatment for CISR (HR = 10.66 [2.53–44.87]; p = 0.001). Treatment of CISR with BMS (HR = 4.08 [1.75–9.48]; p = 0.001) and clinical therapy (HR = 6.29 [1.35–29.38]; p = 0.019) emerged as predictors of a secondary outcome.

Conclusion

Patients with CISR present in most cases with ACS and with a high frequency of adverse events during a medium-term follow-up.  相似文献   

13.

Background

To prevent stent thrombosis (ST) after implantation of drug-eluting stents (DESs) in patients with coronary heart disease, 12-month dual antiplatelet therapy (DAPT) is recommended. However, the optimal long-term antiplatelet regimen is not clear for the patients who have completed the 12-month DAPT.

Methods

We reviewed the data of 755 consecutive patients who had undergone percutaneous coronary intervention (PCI) three years ago and completed 12-month DAPT. They were divided into three groups according to the antiplatelet medication they had used for two years after 12-month DAPT [low-dose clopidogrel (Talcom®, 25mg/d), clopidogrel (Plavix®, 75mg/d) and aspirin (100 mg/d)]. The efficacy (a composite incidence of cardiac death, myocardial infarction and target vessel revascularization) and safety (incidences of bleeding, gastrointestinal trouble and drug discontinuation) were compared among the three groups.

Results

The rates of multi-vessel lesions, prior MI, hemoglobin A1C (HbA1c) and low-density lipoprotein cholesterol were significantly higher in the clopidogrel (75 mg/day) group than in the other two groups (P>0.05 for both comparisons). There was no significant difference in the overall composite incidence of cardiac death, myocardial infarction and target vessel revascularization in the three groups at three years after PCI. The rates of bleeding (especially minor bleeding), gastrointestinal trouble, drug discontinuation and any blood transfusion were markedly lower in the low-dose clopidogrel (25 mg/d) group than in the other two treatment groups (P<0.05).

Conclusions

The 25-mg maintenance dose of clopidogrel after 12-month DAPT may be more preferable to Chinese patients who have undergone DES implantation, because of its lower cost but no less efficacy and safety.  相似文献   

14.

Background

Recent studies have described neo-atherosclerosis, developing inside the stent, as cause of very late stent thrombosis.

Case report

A 59-year-old man, with family history of coronary artery disease, presented to our Department because of anterior ST-segment elevation myocardial infarction. Two years before he had underwent percutaneous coronary intervention with multiple drug-eluting stents (DES) implantation on proximal-mid left anterior descending artery (LAD), and mid-right coronary artery (RCA), respectively. The angiogram revealed stent thrombosis with total occlusion of proximal LAD. Multiple passages with manual thrombus-aspiration catheter were successfully performed with improvement in TIMI flow. Optical Coherence Tomography (OCT) imaging revealed fully expanded stents without areas of inappropriate apposition to vessel wall; and mild to moderate intimal hyperplasia throughout the stented segment, with full covered stent struts; areas of ulcerated and ruptured plaque within the proximal struts of stented segment was depicted with intraluminal protruding material. Thus, an additional bare metal stent (BMS) was deployed inside and overlapping the previous in order to seal this plaque. OCT post procedure revealed optimal stent expansion and apposition, without residual protruding material. At 9-month follow-up patient was alive and free from symptoms. Coronary angiogram revealed patency of implanted stents without significant restenosis.

Conclusions

Neo-atherosclerosis with thrombosis on top of ruptured necrotic plaque core may play a role in the pathophysiology of very late stent thrombosis in both BMS and DES. Our report highlights the role OCT to assess the mechanism of VLST.  相似文献   

15.

Objectives

This study aims to assess the safety and efficacy of a biodegradable polymer-coated Rapamycin-Eluting Stent (Excel) used in conjunction with six-month dual antiplatelet therapy in daily practice.

Background

The polymeric material of cardiac stents has been reported to adversely affect the safety profile of the drug-eluting stents and is also suspected to cause serious long-term complications. It has been proposed that the biodegradable polymer coatings may reduce such late-stage adverse effects.

Methods

This is a prospective, multi-center registry of 654 patients from across 9 cardiology centers in India, who were enrolled and exclusively treated with Excel stents between February 2008 and May 2010. The recommended antiplatelet regimen included clopidogrel and aspirin for 6 months period, followed by lifelong aspirin therapy.

Results

The study population included 46.94% diabetics, 24.31% smokers, 48.93% hypertensives and 14.98% hyperlipidemics. The cumulative rates of major adverse cardiac events were 0.153% at discharge and 1.38% at 12 months. The mean percentage of stenosis was 88.24 ± 9.17% No events occurred between 6 and 12 months.

Conclusions

This multi-center registry study on “real world, all comers” has, thus, showed that EXCEL™ stent which is PLA-coated biodegradable Rapamycin-Eluting Stent exhibited high efficacy and safety profile in treatment of patients undergoing PCI as evidenced by significantly lower rates of MACE and no case of stent thrombosis. There was no event even after DAPT was discontinued after 6 months.  相似文献   

16.

Background

Coronary stent fracture is an under-recognized event but one that has been reported frequently in the drug-eluting stent era. Most reported cases of stent fracture occurred within days to two years after implantation, and are related to stent thrombosis and restenosis.

Case report

Presentation of a 69-year-old male with a history of arterial hypertension and previous percutaneous coronary intervention (PCI), and with implantation of three overlapping drug-eluting stents (DES) on proximal-to-middle left anterior descending artery (LAD). At five-year outpatient evaluation, the patient was found to have a new left bundle branch block associated with mild elevation in Troponin-I value and severe left ventricular dysfunction. The patient recovered as non ST-segment elevation myocardial infarction (NSTEMI) and consequently a new coronary angiography showed total occlusion of proximal LAD with multiple stent fracture. Here we discuss the role of left ventricular dilatation as a contributing factor to late drug-eluting stent fracture.

Conclusion

Different anatomical coronary settings have been described as predisposing factors to stent fracture. Consequently, the remodeling of the left ventricle, together with the rise in diastolic pressure, may have affected the shear stress of LAD stents by increasing mechanical forces produced in the diastolic phase on the epicardial vessel. In addition, left ventricular enlargement could have increased the elongation forces on the stent frames by altering the curvature of the stent. All predisposing factors of stent fracture, including coronary and left ventricular issues, need to be considered before stent implantation to avoid stent fracture and clinical sequelae.  相似文献   

17.

BACKGROUND:

Percutaneous treatment of bifurcation coronary artery disease (BCD) is complex and, in the era of bare metal stents (BMS), was reported to have a high rate of repeat target lesion revascularization (TLR). Paclitaxel drug-eluting stents (PES) have been used in the treatment of BCD, with better overall outcomes than BMS. Also, acute stent thrombosis (AST), with an incidence ranging from 2.7% to 4.3%, has been reported with the use of bifurcation PES, and remains a concern in treating these patients. In the present report, intermediate term outcomes with BCD stenting using TAXUS Express (Boston Scientific, USA) PES are presented from the Genesis Medical Center.

METHODS:

In the present retrospective study, 518 consecutive de novo bifurcation stenting procedures are reported. They were performed in 2005 at the present institution using the TAXUS Express PES. Follow-up data on 312 patients (60.2%) was achieved through telephone interviews and reviews of medical records after a mean of 6.7 months. The primary end point of the present study was the combined end points of cardiac death, nonfatal myocardial infarction (MI) and TLR. Secondary outcomes included the individual end points of death, cardiac death, AST, target vessel revascularization (TVR), TLR, ST elevation MI and non-ST elevation MI on intermediate term follow-up.

RESULTS:

The mean (± SD) age of the patients was 66±12 years. Acute procedural success was 95% (main branch, 99%; side branch, 95.9%). The following intermediate term outcomes with bifurcation drug-eluting stents were: TLR, 6.7%; TVR, 12.2%; definite and probable AST, 1.6%; death, 6.7%; cardiac death, 2.9%; non-ST elevation MI, 0.7%; ST elevation MI, 2.0%; and the combined primary end point, 9.9%. The outcomes for patients who underwent main branch stenting were not statistically different from those with bifurcation stenting, with an overall combined end point favouring main branch stenting alone (5.8% versus 10.8%, P not significant).

CONCLUSION:

The TAXUS Express PES carry acceptable intermediate term outcomes in the treatment of BCD compared with historic controls with BMS, with low TLR, TVR and overall primary combined end point. Main branch stenting alone is safe, with a trend toward fewer adverse events than bifurcation stenting.  相似文献   

18.

Background

The clinical benefit of percutaneous coronary intervention (PCI) for long coronary lesions is unclear; furthermore, concerns have been raised about its safety.

Objectives

To evaluate the predictors of major adverse cardiac events (MACE) associated with PCI using a full metal jacket (FMJ), defined as overlapping drug-eluting stents (DES) measuring > 60 mm in length, for very long lesions.

Methods

We enrolled 136 consecutive patients with long coronary lesions requiring FMJ in our single-center registry. The primary endpoint included the combined occurrence of all-cause death, myocardial infarction (MI), and target vessel revascularization (TVR). Demographic, clinical, angiographic, and procedural variables were evaluated using stepwise Cox regression analysis to determine independent predictors of outcome.

Results

The mean length of stent per lesion was 73.2 ± 12.3 mm and the mean reference vessel diameter was 2.9 ± 0.6 mm. Angiographic success was 96.3%. Freedom from MACE was 94.9% at 30 days and 85.3% at one year. At the one-year follow-up, the all-cause mortality rate was 3.7% (1.5% cardiac deaths), the MI rate was 3.7%, and the incidence of definite or probable stent thrombosis (ST) was 2.9%. Female gender [hazard ratio (HR), 4.40; 95% confidence interval (CI), 1.81-10.66; p = 0.001) and non-right coronary artery PCI (HR, 3.49; 95%CI, 1.42-8.59; p = 0,006) were independent predictors of MACE at one year. Freedom from adverse events at one year was higher in patients with stable angina who underwent PCI (HR, 0.33; 95%CI, 0.13-0.80; p = 0.014).

Conclusions

PCI using FMJ with DES for very long lesions was efficacious but associated with a high rate of ST at the one-year follow-up. However, the rate of cardiac mortality, nonprocedure-related MI, and MACE was relatively low. Target coronary vessel PCI, clinical presentation, and female gender are new contemporary clinical factors that appear to have adverse effects on the outcome of PCI using FMJ for long lesions.  相似文献   

19.

Background

The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia.

Objective

To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent.

Methods

This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure.

Results

Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment.

Conclusions

Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.  相似文献   

20.

Introduction and objectives

Percutaneous coronary intervention is recommended in patients with unprotected left main stenosis non suitable for coronary artery bypass graft. Long-term follow-up of those patients remains uncertain.

Methods

All patients with de novo unprotected left main stenosis treated with stent implantation were consecutively enrolled. Percutaneous coronary intervention was indicated according to the standards of care, taking into account clinical and anatomical conditions unfavorable for coronary artery bypass graft. The primary end point was the occurrence of major adverse cardiac events, a composite of death, nonfatal acute myocardial infarction, or target lesion revascularization.

Results

Of 226 consecutive patients included, 202 (89.4%) were treated with drug-eluting stents. Mean age was 72.1 years, 41.1% had renal dysfunction, and mean Syntax score and EuroSCORE were 28.9 and 7.4, respectively. Angiographic and procedural success was achieved in 99.6% and 92.9% of patients. At 3 years, the rates of major adverse cardiac events, death, nonfatal acute myocardial infarction and target lesion revascularization were 36.2%, 25.2%, 8.4%, 8.0%, respectively. Target lesion revascularization was more frequently observed when ≥2 stents were implanted rather than a single stent (18.5% vs 5.8%, P=.03); and with bare metal stents rather than drug-eluting stents (13.0% vs 7.9%, P=.24). Definite stent thrombosis was observed in 2 patients (0.9%) and probable stent thrombosis in 7 (3.1%). Female sex, impaired left ventricular function, and use of bare metal stents were significantly related with all-cause mortality.

Conclusions

High-risk patients with unprotected left main stenosis treated with percutaneous coronary intervention presented with a high rate of major adverse cardiac events at long-term follow-up. Female sex, impaired left ventricular function, and use of bare metal stents were predictors of poor prognosis.Full English text available from:www.revespcardiol.org  相似文献   