首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Thin boron doped diamond (BDD) film is deposited from trimethyl borate/acetone/hydrogen mixture on Co-cemented tungsten carbide (WC-Co) micro drills by using the hot filament chemical vapor deposition (HFCVD) technique. The boron peak on Raman spectrum confirms the boron incorporation in diamond film. This film is used as an interlayer for subsequent CVD of micro-crystalline diamond (MCD) film. The Rockwell indentation test shows that boron doping could effectively improve the adhesive strength on substrate of as deposited thin diamond films. Dry drilling of graphite is chosen to check the multilayer (BDD + MCD) film performance. For the sake of comparison, machining tests are also carried out under identical conditions using BDD and MCD coated micro drills with no interlayer. The wear mechanism of the tools has been identified and correlated with the criterion used to evaluate the tool life. The results show that the multilayer (BDD + MCD) coated micro drill exhibits the longest tool life. Therefore, thin BDD interlayer is proved to be a new viable alternative and a suitable option for adherent diamond coatings on micro cutting tools.  相似文献   

2.
Cobalt-cemented carbide micro-end mills were coated with diamond grown by chemical vapor deposition (CVD), with the purpose of micro-machining cemented carbides. The diamond coatings were designed with a multilayer architecture, alternating between sub-microcrystalline and nanocrystalline diamond layers. The structure of the coatings was studied by transmission electron microscopy. High adhesion to the chemically pre-treated WC-7Co tool substrates was observed by Rockwell C indentation, with the diamond coatings withstanding a critical load of 1250 N. The coated tools were tested for micro-end-milling of WC-15Co under air-cooling conditions, being able to cut more than 6500 m over a period of 120 min, after which a flank wear of 47.8 μm was attained. The machining performance and wear behavior of the micro-cutters was studied by scanning electron microscopy and energy-dispersive X-ray spectroscopy. Crystallographic analysis through cross-sectional selected area electron diffraction patterns, along with characterization in dark-field and HRTEM modes, provided a possible correlation between interfacial stress relaxation and wear properties of the coatings. Overall, this work demonstrates that high adhesion of diamond coatings can be achieved by proper combination of chemical attack and coating architecture. By preventing catastrophic delamination, multilayer CVD diamond coatings are central towards the enhancement of the wear properties and mechanical robustness of carbide tools used for micro-machining of ultra-hard materials.  相似文献   

3.
The ability of bacteria to adhere to and form biofilms on implant surfaces is the primary cause of implant failure. Implant-associated infections are difficult to treat, as the biofilm mode of growth protects microorganisms from the host’s immune response and antibiotics. Therefore, modifications of implant surfaces that can prevent or delay bacterial adhesion and biofilm formation are highly desired. In addition, the attachment and spreading of bone cells are required for successful tissue integration in orthopedic and dental applications. We propose that polyanionic DNA with a negatively charged phosphate backbone could provide a dual function to repel bacterial adhesion and support host tissue cell attachment. To this end, we developed polyelectrolyte multilayer coatings using chitosan (CS) and DNA on biomaterial surfaces via a layer-by-layer technique. The assembly of these coatings was characterized. Further, we evaluated staphylococcal adhesion and biofilm growth on the coatings as well as cytotoxicity for osteoblast-like cells (SaOS-2 cells), and we correlated these to the layer structure. The CS-DNA multilayer coatings impaired the biofilm formation of Staphylococcus by ~90% on both PMMA and titanium surfaces. The presence of cationic CS as the top layer did not hinder the bacteria-repelling property of the DNA in the coating. The CS-DNA multilayer coatings demonstrated no cytotoxic effect on SaOS-2 cells. Thus, DNA polyelectrolyte multilayer coatings could reduce infection risk while promoting host tissue cell attachment on medical implants.  相似文献   

4.
This study proposes a novel use of laser heating to increase the adhesion between coatings fabricated by low-temperature PVD and replaceable cemented carbide cutting inserts, thus extending the life of these cutting tools in the machining of difficult-to-machine materials. Our previous studies conducted on CVD coatings showed that these coatings had higher adhesion due to a much higher process temperature. However, taking into account the fact that PVD coatings have better technological properties (e.g., lower structure porosity, higher hardness, and better tribological properties) than CVD coatings, it is fully justified to investigate ways of improving the PVD coating adhesion to the substrate. In this study, replaceable cutting inserts with different hard coatings of titanium nitride were used. Laser heating was conducted with different power densities. The adhesion strength of the tested coatings was determined via vibration spectrum analysis. In addition, 2D surface imaging, scanning electron microscopy, and X-ray fluorescence spectrometry were employed to examine the coatings after laser heating. A significant increase in the adhesion of single-layer (TiN) and double-layer (TiCN + TiN) coatings to the cemented carbide substrate, together with increased tool life, was observed after heating the samples with 40% of the maximum laser power. The application of a multilayer coating containing thermal shock-sensitive (TiAlSi) N did not increase the tool life. This paper attempts to interpret the obtained results.  相似文献   

5.
Diamond-incorporated copper metal matrix layers were fabricated on brass substrates by using electrodeposition technology in this study. To improve the adhesion of the composite coatings on the brass substrate, a plated copper was applied as the interlayer between the multilayers and the substrate. The surface morphologies of the interlayer and the diamond-incorporated copper composite layers were studied by scanning electron microscopy. The effect of the copper interlayer on the incorporation and the distribution of the diamond content in the coatings was analyzed by surface roughness, electrochemical impedance spectroscopy, and cyclic voltammetry. The diamond content of the composite coating was measured by energy-dispersive X-ray. The film thickness was evaluated by the cross-sectional technique of focused ion beam microscopy. The element, composition, and crystallization direction of diamond with Cu matrix was measured by X-ray diffraction and transmission electron microscope. The adhesion of the multilayers was studied by scratch tests. The experiment results indicated that the diamond content and distribution of the coating were higher and more uniform with the Cu interlayer than that without one. The plated copper interlayer reduced the electrical double-layer impedance and enhanced the adsorption of diamond particles by the surrounding Cu ions, which promoted the diamond content in the composite coatings. The roughened surface caused by the plated Cu interlayer also improved the substrate’s mechanical interlock with the composite coating, which contributed to the strong adhesion between them.  相似文献   

6.
We evaluated the adhesion, friction characteristics, durability against bodily acids, sterilization, cleaning, and anti-reflection performance of diamond-like carbon (DLC) coatings formed as a surface treatment of intracorporeal medical devices. The major coefficients of friction during intubation in a living body in all environments were lower with DLC coatings than with black chrome plating. DLC demonstrated an adhesion of approximately 24 N, which is eight times stronger than that of black chrome plating. DLC-coated samples also showed significant stability without being damaged during acid immersion and high-pressure steam sterilization, as suggested by the results of durability tests. In addition, the coatings remained unpeeled in a usage environment, and there was no change in the anti-reflection performance of the DLC coatings. In summary, DLC coatings are useful for improving intracorporeal device surfaces and extending the lives of medical devices.  相似文献   

7.
Carbon–chromium carbide–chromium multilayer coatings were deposited by utilizing reactive high-power impulse magnetron sputtering with alternating various ratios of ethyne and argon mixtures under a constant total deposition pressure, target pulse frequency, pulse duty cycle, average chromium target power, and total deposition time. Two different alternating gas mixture periods were applied to obtain films with different numbers of layers and lamination thicknesses. The results show that the reduction in the modulation period effectively affects the elastic modulus and the subsequent ratio of hardness to elastic modulus (H/E) of the whole coating, which helps adapt the elastic strain in the coating. This improves the adhesion strength and wear resistance of coatings at room temperature. However, with the increase in wear test temperature, the difference between the wear behaviors of two types of coatings becomes inconspicuous. Both types of coatings lose the wear resistance due to the decomposition of hydrocarbon and the oxidation of the chromium content in the films.  相似文献   

8.
Control of nonspecific/specific protein adsorption is the main goal in the design of novel biomaterials, implants, drug delivery systems, and sensors. The specific functionalization of biomaterials can be achieved by proper surface modification. One of the important strategies is covering the materials with functional coatings. Therefore, our work aimed to functionalize multilayer coating to control nonspecific/specific protein adsorption. The polyelectrolyte coating was formed using a layer-by-layer technique (LbL) with biocompatible polyelectrolytes poly-L-lysine hydrobromide (PLL) and poly-L-glutamic acid (PGA). Nonspecific protein adsorption was minimized/eliminated by pegylation of multilayer films, which was achieved by adsorption of pegylated polycations (PLL-g-PEG). The influence of poly (ethylene glycol) chain length on eliminating nonspecific protein adsorption was confirmed. Moreover, to achieve specific protein adsorption, the multilayer film was also functionalized by immobilization of antibodies via a streptavidin bridge. The functional coatings were tested, and the adsorption of the following proteins confirmed the ability to control nonspecific/specific adsorption: human serum albumin (HSA), fibrinogen (FIB), fetal bovine serum (FBS), carcinoembryonic antigen human (CEA) monitored by quartz crystal microbalance with dissipation (QCM-D). AFM imaging of unmodified and modified multilayer surfaces was also performed. Functional multilayer films are believed to have the potential as a novel platform for biotechnological applications, such as biosensors and nanocarriers for drug delivery systems.  相似文献   

9.
The layer-by-layer technique was used to build-up polyelectrolyte multilayers (PEMs) composed of heparin, an anionic glycosaminoglycan (GAG) and chitosan, a cationic biodegradable polysaccharide on model biomaterial surfaces. The surface coatings shall control adhesion of cells and thus their subsequent proliferation and differentiation. PEMs were characterized physicochemically by static contact angle and quartz crystal microbalance (QCM) measurements. Variations in procedure parameters such as the pH value of the solutions were crucial to the formation process and surface properties in terms of wettability and mass increase. Cell-surface interactions were studied with human fibroblast on PEMs. It was found that the pH value of solutions had a strong impact on cell adhesion making surfaces extremely cytophobic or moderately cytophilic. Adsorption of fibronectin to the terminal heparin layer could be used to increase cell adhesion in a concentration-dependent manner.  相似文献   

10.
TiO2 in the form of nanoparticles is characterized by high photocatalytic activity and high resistance to oxidation, making it an excellent candidate to realize coatings for improving the corrosion resistance of aluminium surfaces. Different coating technologies have been proposed over the years, which often involve the use of toxic compounds and very high temperatures. In this work, an alternative and novel one-step method for the coating of aluminium alloy surfaces with titania nanoparticles is presented. The method is based on the combination of aerosol flame synthesis and direct thermophoretic deposition and allows to produce nanostructured thin coating layers of titania with different features. Specifically, 3.5 nm anatase nanoparticles were synthesized and deposited onto aluminium alloy AA2024 samples. The thickness of the coating was changed by modifying the total deposition time. A thermal annealing treatment was developed to improve the adhesion of nano-titania on the substrates, and the morphology and structures of the coatings were characterized using (ultra violet) UV-vis absorption, scanning electron microscopy, transmission electron microscopy and Raman spectroscopy. The corrosion resistance behavior of the coatings was evaluated by means of electrochemical polarization measurements, coupled with a numerical analysis using COMSOL software. Both the experimental and numerical electrochemical polarization curves showed a significant increase in the corrosion potential of coated substrates with respect to the bare aluminium and a decrease in the current density. The coatings obtained with higher deposition time and greater thickness showed the best performances in terms of the resistance of the aluminium surfaces to corrosion.  相似文献   

11.
Intumescent coatings are commonly used as passive fire protection systems for steel structures. The purpose of this work is to explore whether these can also be used effectively on glass fibre-reinforced epoxy (GRE) composites, considering the flammability of the composites compared to non-flammable steel substrate. The thermal barrier and reaction-to-fire properties of three commercial intumescent coatings on GRE composites have been studied using a cone calorimeter. Their thermophysical properties in terms of heating rate and/or temperature dependent char expansion ratios and thermal conductivities have been measured and correlated. It has been suggested that these two parameters can be used to design coatings to protect composite laminates of defined thicknesses for specified periods of time. The durability of the coatings to water absorption, peeling, impact, and flexural loading were also studied. A strong adhesion between all types of coatings and the substrate was observed. Water soaking had a little effect on the fire performance of epoxy based coatings. All types of 1 mm thick coatings on GRE helped in retaining ~90% of the flexural property after 2 min exposure to 50 kW/m2 heat flux whereas the uncoated laminate underwent severe delamination and loss in structural integrity after 1 min.  相似文献   

12.
Recent investigations on the anti-adhesive properties of polysulfobetaine methacrylate (pSBMA) coatings had shown promising potential as antifouling surfaces and have given the impetus for the present paper, where a pSBMA coating is applied via photopolymerization on a macro-roughened, sandblasted, and acid-etched titanium implant surface in order to assess its antifouling properties. Current emphasis is placed on how the coating is efficient against the adhesion of Enterococcus faecalis by quantitative assessment of colony forming units and qualitative investigation of fluorescence imaging and scanning electron microscopy. pSBMA coatings via photopolymerization of titanium surfaces seems to be a promising antiadhesion strategy, which should bring substantial benefits once certain aspects such as biodegradation and osseointegration were addressed. Additionally, commercial SAL-titanium substrates may be coated with the super-hydrophilic coating, appearing resistant to physiological salt concentrations and most importantly lowering E. faecalis colonization significantly, compared to titanium substrates in the as-received state. It is very likely that pSBMA coatings may also prevent the adhesion of other germs.  相似文献   

13.
Biofilm formation on implant materials causes a common problem: resistance to aggressive pharmacological agents as well as host defenses. Therefore, to reduce bacterial adhesion to implant surfaces we propose to use silver(I) coordination networks as it is known that silver is the most powerful antimicrobial inorganic agent. As a model surface, self-assembled monolayers (SAMs) on gold Au(111) was used to permit permanent attachment of our silver(I) coordination networks. The surface coatings showed typical nano-structured surfaces with a good biocompatibility for soft-tissue integration with fibroblast cells.  相似文献   

14.
The Kaposi sarcoma-associated herpesvirus (KSHV)-DNA level was determined in samples from 71 patients with Kaposi sarcoma (KS), 28 patients with multicentric Castleman disease (MCD), and 8 patients with primary effusion lymphoma (PEL). KSHV-DNA levels were higher in patients with active KS or MCD than in those with KS or MCD in remission. Among patients with active disease, the highest KSHV-DNA levels were observed in effusion fluid samples from patients with PEL (7.2 log(10) copies/150,000 cells), followed by blood samples from patients with MCD and PEL (4.86 and 3.83 log(10) copies/150,000 cells, respectively), and the lowest levels were observed in blood samples from patients with KS (2.63 log(10) copies/150,000 cells). Determining the KSHV-DNA level may be useful in diagnosing KSHV-associated disease and for following up patients with KS when the development of MCD or PEL is suspected.  相似文献   

15.
Flame-sprayed NiCrBSi/WC-12Co composite coatings were deposited in different ratios on the surface of stainless steel. Oxyacetylene flame remelting treatment was applied to surfaces for refinement of the morphology of the layers and improvement of the coating/substrate adhesion. The performance of the coated specimens to cavitation erosion and electrochemical corrosion was evaluated by an ultrasonic vibratory method and, respectively, by polarization measurements. The microstructure was investigated by means of scanning electron microscopy (SEM) combined with energy dispersive X-ray analysis (EDX). The obtained results demonstrated that the addition of 15 wt.% WC-12Co to the self-fluxing alloy improves the resistance to cavitation erosion (the terminal erosion rate (Vs) decreased with 15% related to that of the NiCrBSi coating) without influencing the good corrosion resistance in NaCl solution. However, a further increase in WC-Co content led to a deterioration of these coating properties (the Vs has doubled related to that of the NiCrBSi coating). Moreover, the corrosion behavior of the latter composite coating was negatively influenced, a fact confirmed by increased values for the corrosion current density (icorr). Based on the achieved experimental results, one may summarize that NiCrBSi/WC-Co composite coatings are able to increase the life cycle of expensive, high-performance components exposed to severe cavitation conditions.  相似文献   

16.
BACKGROUND/AIMS: The administration of a methionine and choline deficient (MCD) diet to mice serves as an animal model of NASH. The multidrug resistant 2 (Mdr2) P-glycoprotein encodes for the canalicular phospholipid transporter, and Mdr2 (+/-) mice secrete 40% less phosphatidylcholine than wild-type mice. We have hypothesized that phosphatidylethanolamine-N-methyl transferase (PEMT) up-regulation is a consequence of MCD diet administration, and is important for the pathogenesis of steatohepatitis in this model. However, the effect of decreased phosphatidylcholine secretion and modulation of PEMT on the development of diet-induced steatohepatitis in Mdr2 (+/-) mice has not been explored. Thus, the purpose of the study is to examine the effects of the MCD diet on Mdr2 (+/-) mice. METHODS: Mdr2 (+/-) and Mdr2 (+/+) mice were treated with an MCD or control diet for up to 30 days, and the severity of steatohepatitis, PEMT activity and hepatic S-adenosylmethionine (SAM), and S-adenosylhomocysteine (SAH) levels were measured. RESULTS: Serum ALT levels, hepatic inflammation, and PEMT activity were significantly lower, and hepatic SAM:SAH ratios were significantly higher in Mdr2 (+/-) mice at 7 and 30 days on the MCD diet. CONCLUSIONS: Mdr2 (+/-) mice have diminished susceptibility to MCD diet-induced NASH, which is associated with a relative decrease in PEMT activity and increased SAM:SAH ratios.  相似文献   

17.
The purpose of this study was to comparatively investigate the behavior of silicate and sol-silicate coatings non-modified or modified with an organosilane on wood and on wood pre-coated with silica-mineralized primers. Adhesion strength, morphology, and water permeability and related damages were studied to evaluate the possibility of utilizing such inorganic-based coating systems for durable protection of wood without or with relatively cheap and water-borne primers. Potassium silicate and potassium methylsiliconate aqueous solutions and a colloidal silica were used for the preparation of the coatings. The white coating paints were brushed on beech wood substrates at a rate of 220 g·m−2. The coatings exhibited good coverage ability. The pull-off adhesion strength values appeared to be related to pH following a polynomial law. The adhesion strength for the silicate coatings were adequate (above 3 MPa and up to 5 MPa) for wood, whereas the values for the sol-silicates were too low for practical applications. The adhesion values were in general higher for the samples cured in a climate room (23 ± 3 °C and 75 ± 2% relative humidity) than the samples cured in the ambient atmosphere of the laboratory (23 ± 3 °C and 25 ± 5% relative humidity). The presence of microdefects (cracks, holes) was revealed in the coating layers by optical and scanning electron microscopy. The surface roughness parameters assessed by confocal scanning laser microscopy were dependent on the magnification applied for their measurement. The arithmetic average roughness Sa was between 5 µm and 10 µm at magnification 5× and between 2.5 μm and 10 µm at magnification 20×. The maximum peak-to-valley height Sz confirmed the presence of open pores emerging through the coatings. The open pores constitute free pathways for water ingress through the coatings, and could explain the high water absorption of the coatings including the methysiliconate-containing silicate coating and despite the relatively high water contact angle and low wettability exhibited by this sample. The post-application of a hydrophobizing solution containing hexadecyltrimethoxysilane and dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride considerably reduced the water permeability, while application of nanosilica-containing organic primers increased the adhesion for the coatings. Silicate coatings with adhesion great enough and resistance against water damages can be generated on wood even without a primer using low silica-to-alkali ratio binders and an organosilane additive. The sol-silicate coatings appear to be applicable only with a primer. The improvement of the paint formulations to control the formation of microcracks and open pores could be useful to reduce the liquid water permeability and increase durability. Otherwise, the application of a hydrophobizing treatment can be used for this purpose.  相似文献   

18.
In this study, we aimed to determine the effect of long-term exposure to artificial urine on the physical properties of CoCrMo alloy with biodegradable heparin-releasing polymeric coatings. Variants of polymer coatings of poly(L,L-lactide-ɛ-caprolactone) (P(L,L-L/CL)) and poly(D,L-lactide-ɛ-caprolactone) (P(D,L-L/CL)) constituting the base for heparin-releasing (HEP) polyvinyl alcohol (PVA) coatings were analyzed. The coatings were applied by the dip-coating method. Heparin was used to counteract the incrustation process in the artificial urine. The study included tests of wettability, resistance to pitting and crevice corrosion, determination of the mass density of metal ions penetrating into the artificial urine, and the kinetics of heparin release. In addition, microscopic observations of surface roughness and adhesion to the metal substrate were performed. Electrolytically polished CoCrMo samples (as a reference level) and samples with polymer coatings were used for the tests. The tests were conducted on samples in the initial state and after 30, 60, and 90 days of exposure to artificial urine. The analysis of the test results shows that the polymer coatings contribute by improving the resistance of the metal substrate to pitting and crevice corrosion in the initial state and reducing (as compared with the metal substrate) the mass density of metal ion release into the artificial urine. Moreover, the PVA + HEP coating, regardless of the base polymer coatings used, contributes to a reduction in the incrustation process in the first 30 days of exposure to the artificial urine.  相似文献   

19.
Multicentric Castleman's disease (MCD) is an atypical lymphoproliferative disorder defined using clinical and pathologic criteria. A characteristic of the MCD is a close association with Kaposi's sarcoma (KS), which occurs during the clinical course of most human immunodeficiency virus (HIV)-associated MCD cases and also, but less frequently, in HIV-negative patients. Recently, sequences of a putative new Herpesvirus (KSHV) have been isolated and further detected in almost all the acquired immunodeficiency syndrome (AIDS) KS and in most of the non-AIDS KS samples. In this study, we searched for these Herpesvirus-like sequences in MCD samples of 31 patients. KSHV sequences were detected in 14 of 14 cases of HIV-associated MCD, including 5 cases without detectable KS. Moreover, KSHV was detected in 7 of 17 MCD cases in HIV-negative patients, including 1 case associated with a cutaneous KS. In 34 non-MCD reactive lymph nodes (follicular and/or interfollicular hyperplasia) in HIV-negative patients, KSHV was detected in only 1 case. In 1 HIV-negative case of MCD, KSHV was found in both the lymph node and peripheral blood samples. These data suggest that KSHV could play a role in the pathogenesis of MCD, especially in HIV-infected patients.  相似文献   

20.
Zein coatings were obtained by electrophoretic deposition (EPD) on commercially pure titanium substrates in an as-received state and after various chemical treatments. The properties of the zein solution, zeta potential and conductivity, at varying pH values were investigated. It was found that the zein content and the ratio of water to ethanol of the solution used for EPD, as well as the process voltage value and time, significantly influence the morphology of coatings. The deposits obtained from the solution containing 150 g/L and 200 g/L of zein and 10 vol % of water and 90 vol % of ethanol, about 4–5 μm thick, were dense and homogeneous. The effect of chemical treatment of the Ti substrate surface prior to EPD on coating adhesion to the substrate was determined. The coatings showed the highest adhesion to the as-received and anodized substrates due to the presence of a thick TiO2 layer on their surfaces and the presence of specific surface features. Coated titanium substrates showed slightly lower electrochemical corrosion resistance than the uncoated one in Ringer’s solution. The coatings showed a well-developed surface topography compared to the as-received substrate, and they demonstrated hydrophilic nature. The present results provide new insights for the further development of zein-based composite coatings for biomedical engineering applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号