首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this case of prolonged fever and abnormal liver functions, dual tracer scintigraphy with In-111 WBCs and Tc-99m SC led to a biopsy-proven diagnosis of severe acute toxic hepatitis (hepatocellular necrosis). Correlation of the Tc-99m SC scan findings with those previously reported for "pseudotumors" of the liver is discussed. A "pseudonormal" scan pattern is described for the In-111 WBC scintigraphy. Discordance between In-111 WBC and Tc-99m SC scintigraphy in this clinical setting should raise the possibility of hepatic necrosis as a diagnostic alternative to hepatic abscess.  相似文献   

2.
Since indium-111 white blood cell (In-111 WBC) scintigraphy is often used to evaluate for osteomyelitis in bone fractures, it is important to know if noninfected fractures have In-111 WBC uptake. Twenty-seven noninfected closed fracture sites in 19 patients were prospectively evaluated with technetium-99m methylene diphosphonate bone scintigraphy and In-111 WBC scintigraphy. In-111 WBC uptake was present in 41% of the 27 sites. In the 11 positive sites, the In-111 WBC uptake was 1+ (definite but minimal) in 55%, 2+ (moderate) in 36%, and 3+ (marked) in 9%. The visual intensity of the radioactive uptake on In-111 WBC scintigrams relative to that on bone scintigrams was less in 82%, equal in 9%, and greater in 9%. The visual size of the area of uptake on In-111 WBC scintigrams and bone scintigrams was smaller in 36%, equal in 55%, and greater in 9%. Factors that may help distinction of In-111 WBC uptake due to fracture alone from infection associated with fracture are discussed.  相似文献   

3.
The usefulness of indium-111 white blood cell scintigraphy in the diagnosis of subacute or chronic bone infection was examined in 21 orthopedic patients. In-111 WBC imaging was compared with gallium-67 and technetium-99m methylene diphosphonate skeletal scintigraphy and bone radiography, all studies being performed within 1 week. In-111 WBC scintigraphy showed no definite advantage over Ga-67 scintigraphy in the identification of chronic bone infection. The two tests had the same sensitivity (80%) and similar specificity (In-111 WBC 75%, Ga-67 83%; difference not significant). Bone radiography had a sensitivity of 60% and a specificity of 67%. A negative Tc-99m MDP bone scintigram ruled out infection (sensitivity 100%), but because of low specificity (25%), final evaluation required performance of Ga-67 or In-111 WBC scintigraphy.  相似文献   

4.
Technetium-99m sulfur colloid (SC) and indium-111 labeled leukocyte (In-111 WBC) scintigraphy was performed on a 77-year-old female patient to rule out a left periprosthetic infection. Anterior Tc-99m SC and In-111 WBC images of the pelvis and femurs revealed no abnormal deposition of radiotracer about the Austin-Moore prosthesis. Absent radiotracer uptake, however, was demonstrated within the left hemipelvis. A left iliac bone marrow aspirate and biopsy revealed a lymphoplasmacytic infiltrate consistent with Waldenstrom's macroglobulinemia.  相似文献   

5.
In-111 labeled leukocyte scintigraphy is a sensitive test for the diagnosis of prosthetic vascular graft infections. However, several causes of false-positive results have been reported. The authors describe a case of uninfected lymphocele around a synthetic vascular graft in a patient who showed an infected graft on In-111 labeled leukocyte scintigraphy.  相似文献   

6.
OBJECTIVES: This is a retrospective study to evaluate a 3-hour In-111-labeled leukocyte image as a surrogate for a Tc-99m nanocolloid marrow scan in the investigation of suspected orthopedic infection using In-111 leukocyte scintigraphy. METHODS: Images from 51 patients who had received contemporaneous In-111-labeled leukocyte scintigraphy and Tc-99m nanocolloid marrow scintigraphy were reviewed. Initially, the 3-hour and 22-hour In-111-labeled leukocyte images were compared. Sites of abnormal uptake on the 22-hour image were correlated with the 3-hour image and were graded according to the level of concordance or discordance. One week later, the Tc-99m nanocolloid images and 22-hour In-111-labeled leukocyte images of the same patients were compared and graded for concordance or discordance. When discrepancies in grading arose between the observers, a consensus opinion was achieved after additional review of the images a week later. RESULTS: On inspection of the 22-hour In-111 leukocyte images, 93 sites of focal, potentially abnormal leukocyte accumulation were identified. When the grading system was reduced to simply "concordant" or "discordant," there was good agreement between the observers in the majority of cases, with kappa statistics 0.77 for Tc-99m nanocolloid versus 22-hour In-111-labeled leukocyte images and 0.78 for 3-hour versus 22-hour In-111-labeled leukocyte images. Using the comparison of the Tc-99m nanocolloid marrow scan and the 22-hour In-111-labeled leukocyte images to identify concordance or discordance as the "gold standard" for scintigraphic evaluation of suspected orthopedic infection, comparison of the 3-hour In-111-labeled leukocyte images with the 3-hour In-111-labeled leukocyte images gave a sensitivity of 77%, a specificity of 77%, and an accuracy of 77%. CONCLUSIONS: A 3-hour image is helpful using In-111-labeled leukocyte scintigraphy.  相似文献   

7.
PURPOSE: Unusual pulmonary uptake of In-111 chloride in a patient with Pneumocystis carinii pneumonia and autoimmune hepatitis is described. METHOD: In-111 chloride bone marrow scintigraphy was performed to evaluate the bone marrow activity associated with pancytopenia in a 56-year-old woman with autoimmune hepatitis. RESULTS: An In-111 chloride bone marrow scan showed increased pulmonary uptake predominantly in both upper lung fields. P. carinii pneumonia was seen to be developing as an immunocompromised complication after treatment for autoimmune hepatitis. CONCLUSION: When In-111 chloride bone marrow scintigraphy shows increased uptake in the lungs of immunocompromised patients, a combined opportunistic inflammatory disease such as P. carinii pneumonia should be considered in the diagnosis.  相似文献   

8.
When infection of prosthetic orthopedic implants is suspected, optimal management requires accurate confirmation or exclusion of infection. The authors retrospectively studied 98 patients with possible infection who underwent scanning with indium-111-labeled white blood cells (WBCs) and subsequently underwent surgery within 14 days. At surgery, 50 patients had infections, as determined by means of culture or histologic results. The diagnostic accuracy of In-111 scanning was compared with that of plain radiography, arthrography, three-phase bone scanning, and various clinical and laboratory findings classically associated with infection. Positive findings on In-111 WBC scans and elevated erythrocyte sedimentation rates were found to be the most predictive variables in the diagnosis of septic prostheses (P less than or equal to .001 and P less than or equal to .002, respectively). Likelihood ratio analysis more clearly demonstrated the superiority of In-111 WBC scanning, with positive and negative scans yielding likelihood ratios of 5.0 and 0.16, respectively.  相似文献   

9.
Gilbert  BR; Cerqueira  MD; Vea  HW; Nelp  WB 《Radiology》1986,158(3):761-763
Indium-111 (In-111) leukocyte scintigraphy was performed in two patients with postsurgical pseudoaneurysms as part of preoperative evaluation for evidence of graft infection. Despite positive In-111 uptake by the pseudoaneurysms, surgical and pathologic examinations failed to reveal any evidence of infection. The most likely explanation for the false-positive results is the labeling of "contaminating" platelets and erythrocytes in the leukocyte mixture. Caution must be exercised in interpretation of In-111 leukocyte scans in patients with postsurgical pseudoaneurysms.  相似文献   

10.
Major neuroendocrine tumors contain many somatostatin receptors. This feature allows for the localization of primary tumors and tumor metastases by scintigraphy with the radiolabeled somatostatin analog octreotide. We describe a patient with nonspecific clinical data and ultrasonography and CT that showed an isolated focal lesion in the liver. In-111 octreotide scintigraphy was essential in establishing the diagnosis of liver metastasis from a neuroendocrine tumor confirmed by pathologic findings. Because clinical symptoms recurred, ultrasonography and CT were performed a few months after surgery. Both were negative. However, In-111 octreotide scintigraphy suggested multiple bone metastases and established the diagnosis of bone metastases from a neuroendocrine tumor, which was confirmed by Tc-99m MDP bone scans and MRI.  相似文献   

11.
The localization of In-111 labeled leukocytes (WBCs) in recent surgical incisions was studied in 18 patients. In-111 WBC images correlated well with culture results and clinical findings. No accumulation of In-111 WBCs was detected at the site of noninfected incisions in nine patients. In-111 WBCs did accumulate at incision sites in nine patients with infected surgical incisions. These results indicate that In-111 WBC study can accurately distinguish between normal healing and infection of recent surgical incisions.  相似文献   

12.
Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acute DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal.  相似文献   

13.
The liver was not visualized by In-111 WBC scan in a patient with alcoholic liver disease. The liver was visualized on repeat scan when liver function had improved.  相似文献   

14.
A false-negative In-111 WBC scan was obtained in a case of a large, infected hemophiliac pseudotumor. Following aspiration of the abscess, a positive scan was seen, demonstrating that In-111 WBC imaging occasionally may be misleading as a diagnostic tool.  相似文献   

15.
A young patient with sickle cell disease (SCD) and multiple hospitalizations for crisis was admitted because of suspected osteomyelitis. Initial laboratory work, radiographs, and bone images were not contributory. An In-111 white blood cell (WBC) study demonstrated two areas of increased radionuclide uptake consistent with osteomyelitis. One of these had associated soft tissue infection. No other areas of active osteomyelitis were visualized, in spite of the presence of several additional infection sites. Imaging with In-111 WBC is probably not justified for routine diagnosis of acute osteomyelitis in areas free of previous disease, where conventional bone images are highly efficient. In-111 WBC imaging, however, may be helpful in detecting osteomyelitis in selected patients with SCD in whom Tc-99m bone images and radiographs are usually abnormal and difficult to interpret due to previous bone infarcts. Localization of the infection focus is very important in choosing the aspiration site for bacteriologic studies. A negative study, however, should be interpreted cautiously.  相似文献   

16.
PURPOSE: In this retrospective study, the authors evaluated the utility of In-111 octreotide (OctreoScan) and Tc-99m (V) DMSA scintigraphy for the localization of recurrent metastatic tumor foci in patients with medullary thyroid cancer (MTC) and compared the findings with those of conventional radiologic imaging methods. METHODS: The scintigraphic images were compared with computed tomography (CT) and magnetic resonance imaging (MRI) and ultrasonography (US) in 14 patients (8 men, 6 women; age range, 22 to 74 years) with elevated calcitonin and carcinoembryonic antigen levels after total thyroidectomy. All scintigraphic image findings were evaluated qualitatively as mild uptake (+) and moderate to marked uptake (++). RESULTS: In-111 octreotide may be superior to Tc-99m (V) DMSA for the detection of tumor foci of patients with MTC on a patient basis (78.5% versus 57.1%) and on a lesion basis (44.1% versus 30.2%). The sensitivity rate for In-111 octreotide (78.5%) was also similar to that of CT and MRI on a patient basis. Conversely, the combined use of Tc-99m (V) DMSA and In-111 octreotide revealed the best sensitivity rate (85.7%) on a patient basis, whereas the combined use of CT and MRI showed the best sensitivity rate (81.3%) on a lesion basis. CONCLUSIONS: These findings suggest that In-111 octreotide is superior to Tc-99m (V) DMSA and has a similar sensitivity rate to CT and MRI for the diagnosis of recurrent or metastatic MTC. Although the combined use of In-111 octreotide and Tc-99m (V) DMSA was most sensitive, the combined use of CT and MRI with radionuclide imaging methods may better detect more metastatic tumor foci.  相似文献   

17.
In order to detect the infectious foci in a case of terminal recurrent cancer of the sigmoid colon with intense inflammation, In-111 oxine leukocyte scintigraphy was performed. Leukocytes labeled with In-111 oxine quickly localized within the region of peritonitis carcinomatosa and could be imaged after 4 hours. With time, high activity appeared in this area. And 48 hours after injection, the large intestine was clearly seen. However, no activity was seen in the main recurrent tumor. This suggested that the labeled leukocytes had accumulated in regions of inflammation rather than in malignant tissue. When performing In-111 leukocyte scintigraphy for diseases in which tumor cells and inflammation are mixed, distinguishing the two components is particularly important, and time-sequential scanning is very useful.  相似文献   

18.
Cardiac aneurysm complicated by E. coli abscess   总被引:1,自引:0,他引:1  
An E. coli myocardial abscess developed in the region of an old aneurysmal myocardial scar. In spite of vigorous antibiotic therapy fever and positive blood cultures persisted. A combination of In-111 WBC scanning and Tc-99m RBC gated heart imaging located the infection in the aneurysmal scar. The abscess was resected and the patient survived.  相似文献   

19.
In-111 oxine WBC abdominal scanning is now a widely accepted technique for the detection of abdominal infectious processes. High sensitivity and specificity are achieved. In-111 labeled leukocyte accumulation, however, does not always suggest the diagnosis of abscess. Higher specificity could be obtained by the knowledge of the In-111 leukocyte distribution pattern in the abdomen in other pathologic states like inflammation of abdominal wounds, stoma; surgical complication without abscess formation; inflammatory or ischemic bowel disease; or swallowing leukocytes which subsequently are visualized in the intestinal lumen. One hundred fifty-two consecutive WBC scans performed over 18 months were reviewed and classified according to their pattern of uptake: 96 cases showed no abdominal uptake, and 56 had accumulation of leukocytes in the abdomen. Twenty-eight of these patients had proven abdominal abscess, and the remaining 26 were positive due to other causes. This report briefly discusses the distribution pattern of In-111 labeled leukocytes in the latter patients and compares the results obtained using different diagnostic criteria.  相似文献   

20.
Preoperative exclusion or confirmation of periprosthetic infection is essential for correct surgical management of patients with suspected infected joint prostheses. The sensitivity and specificity of [111In]WBC imaging in the diagnosis of infected total joint prostheses was examined in 28 patients and compared with sequential [99mTc]HDP/[111In]WBC scintigraphy and aspiration arthrography. The sensitivity of preoperative aspiration cultures was 12%, with a specificity of 81% and an accuracy of 58%. The sensitivity of [111In]WBC imaging alone was 100%, with a specificity of 50% and an accuracy of 65%. When correlated with the bone scintigraphy and read as sequential [99mTc]HDP/[111In]WBC imaging, the sensitivity was 88%, specificity 95%, and accuracy 93%. This study demonstrates that [111In]WBC imaging is an extremely sensitive imaging modality for the detection of occult infection of joint prostheses. It also demonstrates the necessity of correlating [111In]WBC images with [99mTc]HDP skeletal scintigraphy in the detection of occult periprosthetic infection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号