首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
目的 探讨磁共振血管造影(MRA)、CT血管造影(CTA)在诊断颈动脉狭窄及内膜切除术后随访中的价值。方法 11例22支颈动脉行MRA、CTA、CT仿真内窥镜(CTVE)、多普勒超声(DUS)检查。12支结果与DSA对照。3支颈动脉重度狭窄者行内膜切除术,MRA采用二维、三维时间飞越法。CTA经最大强度投影(MIP)及遮盖表现显示法(SSD)三维重建。应用导航功能行CTVE成像。结果 颈动脉轻度狭窄8支,中度狭窄3支,重度狭窄5支,闭塞1支,5支正常。12支颈动脉与DSA对照:CTA评估血管狭窄与DSA相符者11支,MRA与DSA相符者9支,DUS与DSA相符者7支。CTA、CTVE显示斑块、壁血栓6支,3支手术证实。术后MRA示狭窄解除,CTA示斑块消失。结论 MRA、DUS可用于颈动脉狭窄的筛选及术后随访。CTA评估血管狭窄程度与DSA、手术比较有较好的一致性,并能直接显示钙化斑块。  相似文献   

2.
PURPOSE: To assess how often rotational angiography depicts more severe internal carotid arterial stenosis compared with conventional intraarterial digital subtraction angiography (DSA) in two or three projections and how frequently this factor may affect patient treatment. MATERIALS AND METHODS: Rotational angiography (16 or 32 projections) was performed in addition to DSA in 47 stenotic internal carotid arteries (ICAs) in 38 symptomatic patients. ICA stenosis was measured independently at DSA and at rotational angiography with North American Symptomatic Carotid Endarterectomy Trial criteria. The degree of stenosis was categorized as 0%-29%, 30%-49%, 50%-69%, or 70%-99%. RESULTS: In three ICAs, rotational angiography was nondiagnostic. In 28 of the remaining 44 ICAs, the degree of stenosis was categorized similarly with DSA and rotational angiography, whereas with rotational angiography, 15 ICAs were classified one category higher and one ICA was classified two categories higher, owing to the increased number of projections available. Seventy percent to 99% stenosis was demonstrated in 18 ICAs with DSA and in 25 ICAs with rotational angiography. Thus, rotational angiography could have facilitated a change in the optimal treatment (from nonsurgical treatment to carotid arterial endarterectomy) in seven ICAs. CONCLUSION: Compared with DSA in two or three projections, rotational angiography frequently depicts more severe ICA stenosis. This indicates a limitation of DSA in depicting the maximum ICA stenosis.  相似文献   

3.
PURPOSE: To determine whether contrast-enhanced 3D MR angiography (CE MRA) could replace digital subtraction angiography (DSA) for the evaluation of atherosclerotic peripheral vascular disease of the lower leg and foot. MATERIAL AND METHODS: Thirty-five patients with symptoms of atherosclerotic disease of the leg were examined prospectively with CE MRA of the foot and the lower legs as well as with DSA from the aorta to the pedal arches. The MRA technique was focused on optimal imaging of the arteries of the foot. RESULTS: The agreement between CE MRA and DSA for grading of stenosis was moderate to good (weighted kappa-values 0.48-0.80). The sensitivity of CE MRA for detection of significant stenosis (> or = 50%) was 92% and the specificity was 64% with DSA as gold standard. CONCLUSION: CE MRA is a fairly accurate method for the demonstration of atherosclerotic disease below the knee including the pedal arches. It can replace DSA for the assessment of distal arteries in patients with impaired renal function. However, image quality and resolution still needs to be improved before CE MRA can become the method of choice in all patients.  相似文献   

4.
BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography (CE MRA) is a proven diagnostic tool in evaluation of the carotid arteries; however, few studies have addressed its accuracy in the vertebrobasilar system. The purpose of this study was to assess the sensitivity and specificity of CE MRA compared with digital subtraction angiography (DSA) for detection of vertebrobasilar disease. METHODS: Forty patients with suspected atherosclerotic disease of the carotid and vertebrobasilar circulations underwent CE MRA on a 1.5 T MR imaging scanner by use of a coronal 3D gradient-echo pulse sequence after intravenous injection of gadolinium diethylene triamine penta-acetic acid. All patients had correlative DSA within a 1-month period. CE MRA images were randomized and then independently assessed by 2 observers who were blinded to the DSA results. DSA examinations were analyzed in a similar manner. Each observer was asked to report the presence or absence of clinically significant stenosis (>50%), occlusion, fistula, aneurysm, and dissection. The MRA findings were then correlated with DSA. RESULTS: The sensitivity and specificity of MRA for detection of disease in the entire carotid and vertebrobasilar systems were 90% and 97%, respectively; for the carotid system alone, the sensitivity and specificity were 94% and 97%, respectively; and for the vertebrobasilar system they were 88% and 98% respectively. The overall interobserver reliability was 98% (kappa = 0.92). CONCLUSION: CE MRA is accurate at detecting disease not only in the carotid vessels, but also in the vertebrobasilar circulation, and has the potential to provide a comprehensive and noninvasive evaluation of the head and neck arteries in a single study.  相似文献   

5.
目的探讨三维对比增强磁共振血管成像(3D CE-MRA)在颈部动脉血管狭窄诊断中的临床应用价值。方法对23例临床拟诊颈部动脉血管狭窄行数字减影血管造影(DSA)的患者行颈部3D CE-MRA。将两种方法检查结果进行相关性比较。结果 23例患者共230个节段血管,3D CE-MRA显示了227个节段,共诊断出74处(32.6%)狭窄,其中28处轻度狭窄,22处中度狭窄,20处重度狭窄,4处闭塞;DSA共显示了230个节段的血管,共诊断出69处(30.4%)血管狭窄,其中24处轻度狭窄,23处中度狭窄,19处重度狭窄,3处闭塞。与DSA相比,3DCE-MRA对颈部动脉轻度、中度、重度狭窄及动脉闭塞的显示敏感性均为100%,特异性分别为85.71%、90.91%、90%和75%,两种检查方法对颈部动脉狭窄程度的判断有良好的一致性(κ=0.921,P=0.000)。结论 3.0T 3DCE-MRA能够可靠的评价颈部动脉狭窄性病变,基本可以替代DSA检查。  相似文献   

6.
目的:评价高分辨力三维增强磁共振血管成像术(3DCEMRA)对肾动脉狭窄的显示准确性。方法:对30例临床诊断或怀疑肾动脉狭窄患者进行高分辨力肾动脉3DCEMRA检查,分析所有患者的肾动脉和副肾动脉显示质量和病变显示情况,并与DSA做对照。结果:3DCEMRA显示了30例患者总共59支肾动脉主干(1例为单支移植肾动脉),显示率为100%。3DCEMRA显示4支副肾动脉,显示率100%。肾动脉段级分支的显示率为49%。所有病例在动脉显示区域内静脉均未显影或显影淡,对诊断不构成影响。DSA共显示59支肾动脉主干和4支副肾动脉(以63支计算),59支主干中2支闭塞,8支重度狭窄,11支中度狭窄,10支轻度狭窄,28支肾动脉主干和4支副肾动脉都正常。3DCEMRA除把2支轻度狭窄估为中度狭窄,1支中度狭窄估为重度狭窄外,其它结果都同DSA一致,故3DCEMRA显示肾动脉主干和副肾动脉狭窄程度超过50%的有血液动力学意义的明显狭窄的敏感性和特异性分别为100%和95%,阳性预测值为91%,阴性预测值为100%。结论:高分辨力肾动脉3DCEMRA能准确检出肾动脉主干和副肾动脉狭窄,并能较好判断其狭窄程度。  相似文献   

7.
PURPOSE: To compare three different magnetic resonance angiography (MRA) techniques with x-ray angiography and endarterectomy specimens. MATERIALS AND METHODS: Twenty-one patients underwent x-ray angiography, three-dimensional time-of-flight (TOF) focusing on the carotid bifurcation, high-resolution (HR) contrast-enhanced (CE) MRA, and time-resolved CE MRA. Stenoses of internal carotid arteries were evaluated by three independent observers on identical projection of x-ray angiography and MRA. Maximum stenosis grades on MRA were assessed additionally and correlated with endarterectomy specimens in 12 cases. RESULTS: Sensitivity for the detection of severe stenoses was excellent (100%) for all MRA techniques, and specificity was superior for three-dimensional TOF (96.7%) compared with HR CE MRA (80.6%) and time-resolved CE MRA (83.9%). The correlation between x-ray angiography and MRA for all stenoses was slightly superior for three-dimensional TOF and HR CE MRA compared with the time-resolved technique (kappa = 0.87 and 0.86 vs. 0.84). The same trend was seen for the interobserver agreement and for the correlation with endarterectomy specimens. Eleven up to 17 stenoses (depending on the MRA technique) were graded higher using additional projections. CONCLUSION: Three-dimensional TOF MRA yielded even more accurate results than HR CE MRA in grading of stenoses near the carotid bifurcation. Therefore, a combination of both methods seems to be advantageous.  相似文献   

8.
3D TRICKS MRA对颈动脉粥样硬化狭窄的诊断价值   总被引:1,自引:0,他引:1       下载免费PDF全文
目的:探讨3D TRICKS MRA对颈动脉粥样硬化狭窄的诊断价值。方法:对43例临床疑诊颈动脉粥样硬化狭窄的患者行2D TOF MRA和3D TRICKS MRA检查,其中31例同期行DSA检查,以颈总动脉法(CC法)计算狭窄率。结果:颈动脉闭塞2支,重度狭窄10支,中度狭窄31支,轻度狭窄25支,正常18支。2D TOF MRA、3D TRICKS MRA与DSA对照,显示狭窄部位均与DSA所示相符。2D TOF MRA高估狭窄程度6支,3D TRICKS MRA高估狭窄程度1支。以DSA为标准,2D TOF MRA诊断颈动脉狭窄的敏感度、特异度、诊断符合率分别为91.6%,85.7%,90.3%(K=0.737);3D TRICKS MRA诊断颈动脉狭窄的敏感度、特异度、诊断符合率分别为97.9%,100%,98.4%(K=0.955)。两种方法对诊断颈动脉狭窄的敏感度、特异度和诊断符合率差异均具有统计学意义(P〈0.05)。结论:3D TRICKS MRA与DSA对评估颈动脉粥样硬化狭窄具有极好的一致性(K=0.955),明显优于2D TOF MRA(K=0.737,P〈0.05),是对颈动脉粥样硬化狭窄筛查、术前评估、术后随访的最佳检查方法,能基本替代DSA检查。  相似文献   

9.
BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) is the reference standard for assessing carotid arteries, it is uncomfortable for patients and has a small risk of disabling stroke and death. These problems have fueled the use of spiral CT angiography and MR angiography. We prospectively compared elliptic centric contrast-enhanced MR angiography and spiral CT angiography with conventional DSA for detecting carotid artery stenosis. METHODS: Eighty carotid arteries (in 40 symptomatic patients) were assessed. Elliptic centric MR and spiral CT angiographic data were reconstructed with maximum intensity projection and multiplanar reconstruction techniques. All patients had been referred for DSA evaluation on the basis of findings at Doppler sonography, which served as a screening method (degree of stenosis > or = 70% or inconclusive results). Degree of carotid stenosis estimated by using the three modalities was compared. RESULTS: Significant correlation with DSA was found for stenosis degree for both elliptic centric MR and spiral CT angiography; however, the correlation coefficient was higher for MR than for CT angiography (r = 0.98 vs r = 0.86). Underestimation of stenoses of 70-99% occurred in one case with elliptic centric MR angiography (a 70% stenosis was underestimated as 65%) and in nine cases with spiral CT angiography, in comparison to DSA findings. Overestimation occurred in two cases with MR angiography (stenoses of 65-67% were overestimated as 70-75%). With CT, overestimation occurred in seven cases; a stenosis of 60% in one case was overestimated as 70%. Both techniques confirmed the three cases of carotid occlusion. With elliptic centric MR angiography, carotid stenoses of 70% or greater were detected with high sensitivity, 97.1%; specificity, 95.2%; likelihood ratio (LR) for a positive test result, 20.4; and ratio of LR(+) to LR(-), -0.3. With spiral CT angiography, sensitivity, specificity, LR(+), and LR(+):LR(-) were 74.3%, 97.6%, 31.2, and 0.3, respectively. CONCLUSION: Elliptic centric contrast-enhanced MR angiography is more accurate than spiral CT angiography to adequately evaluate carotid stenosis. Furthermore, elliptic centric contrast-enhanced MR angiography appears to be adequate to replace conventional DSA in most patients examined.  相似文献   

10.
BACKGROUND AND PURPOSE: Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also evaluated the diagnostic performance of CT angiography compared with digital subtraction angiography (DSA). METHODS: In 35 patients, CT angiograms of 70 carotid arteries were compared with DSA images, and CT angiograms of 33 carotid arteries were compared with rotational angiograms. CT angiographic interpretation was performed first interactively at a workstation. Diameter measurements of normal and stenosed carotid arteries were performed on cross-sectional and oblique sagittal MPRs. Degree of stenosis was calculated per North American Symptomatic Carotid Endarterectomy Trial criteria independently by two observers for each technique. RESULTS: Degree of stenosis was slightly underestimated with CT angiography, with mean differences (+/- SD) per observer of 6.9 +/- 17.6% and 10.7 +/- 16.1% for cross-sectional and 2.8 +/- 19.2% and 9.1 +/- 16.8% for oblique sagittal MPRs compared with rotational angiography. CT angiography was somewhat inaccurate for measuring the absolute minimal diameter of high-grade stenoses. On symptomatic sides (n = 35), interactive CT angiographic interpretation combined with MPR measurements for lesions with a visual estimate of 50% or greater stenosis achieved a sensitivity of 95% (20/21) and specificity of 93% (13/14) in the detection of carotid stenosis (>/= 50%) verified with DSA. CONCLUSION: Regardless of slight underestimation of carotid stenosis with CT angiography compared with rotational angiography, diagnostic performance of CT angiography with interactive interpretation proved to be good. Also, the method is highly sensitive for detection of carotid artery stenosis, indicating the suitability of CT angiography as a screening method for symptomatic patients. For hemodynamically significant stenoses revealed by CT angiographic screening, conventional angiography still seems to be necessary.  相似文献   

11.
目的 通过与DSA对照,探讨透视触发3DCE MRA在颈部动脉狭窄诊断中应用价值。方法 回顾性分析60例经DSA确诊的颈部动脉狭窄患者的3DCE MRA影像资料,以血管狭窄部位、数目及程度等作为分析指标,由两位放射科医师进行比较分析。结果 60例患者中3DCE MRA共发现狭窄血管126处,其中轻度49处,中度41处,重度29处,闭塞7处。DSA诊断相应部位血管狭窄124处,其中轻度狭窄49处、中度狭窄40处、重度狭窄29处、闭塞6处;3DCE MRA与DSA对颈部动脉狭窄的诊断结果的一致性较好。结论 透视触发3DCE MRA能够清晰显示颈部动脉狭窄性病变情况,具有广泛的临床应用价值,可基本替代诊断性DSA。  相似文献   

12.
PURPOSE: To prospectively determine, for both digital subtraction angiography (DSA) and contrast material-enhanced magnetic resonance (MR) angiography, the accuracy of subjective visual impression (SVI) in the evaluation of internal carotid artery (ICA) stenosis, with objective caliper measurements serving as the reference standard. MATERIALS AND METHODS: Local ethics committee approval and written informed patient consent were obtained. A total of 142 symptomatic patients (41 women, 101 men; mean age, 70 years; age range, 44-89 years) suspected of having ICA stenosis on the basis of Doppler ultrasonographic findings underwent both DSA and contrast-enhanced MR angiography. With each modality, three independent neuroradiologists who were blinded to other test results first visually estimated and subsequently objectively measured stenoses. Diagnostic accuracy and percentage misclassification for correct categorization of 70%-99% stenosis were calculated for SVI, with objective measurements serving as the reference standard. Interobserver variability was determined with kappa statistics. RESULTS: After exclusion of arteries that were unsuitable for measurement, 180 vessels remained for analysis with DSA and 159 vessels remained for analysis with contrast-enhanced MR angiography. With respect to 70%-99% stenosis, SVI was associated with average misclassification of 8.9% for DSA (8.9%, 7.8%, and 10.0% for readers A, B, and C, respectively) and of 11.7% for contrast-enhanced MR angiography (11.3%, 8.8%, and 15.1% for readers A, B, and C, respectively). Negative predictive values were excellent (92.3%-100%). Interobserver variability was higher for SVI (DSA, kappa = 0.62-0.71; contrast-enhanced MR angiography, kappa = 0.57-0.69) than for objective measurements (DSA, kappa = 0.75-0.80; contrast-enhanced MR angiography, kappa = 0.66-0.72). CONCLUSION: SVI alone is not recommended for evaluation of ICA stenosis with both DSA and contrast-enhanced MR angiography. SVI may be acceptable as an initial screening tool to exclude the presence of 70%-99% stenosis, but caliper measurements are warranted to confirm the presence of such stenosis.  相似文献   

13.
Renal artery stenosis (RAS) is a treatable cause of hypertension and renal failure for which no ideal screening technique is currently available. We evaluated the use of dynamic gadolinium-enhanced magnetic resonance angiography (MRA) for the diagnosis of RAS. Sixty-two patients with secondary hypertension were enrolled in the study. All patients had conventional renal angiography and gadolinium enhanced MRA. The sequence used was a 3D FMP SPGR sequence with the following parameters (TR: 26 ms, TE: 6.9 ms, flip angle 40 °, field of view 36 × 36 cm, matrix 246 × 256, 1 excitation). Gadolinium 0.3 mmol/kg was administered and 60 1.5-mm-thick partitions were obtained over a duration of 3.5 min. The MRA images were then compared with conventional digital subtraction angiography (DSA) images. Conventional DSA demonstrated 138 renal arteries, whereas gadolinium-enhanced MRA demonstrated 129 (93 %). Twenty-one renal artery stenoses and four occluded arteries were seen at conventional DSA. Gadolinium-enhanced MRA had a sensitivity of 88 %, specificity of 98 %, accuracy of 96 %, positive predictive value of 92 % and negative predictive value of 97 % when compared with conventional DSA. Gadolinium-enhanced MRA is an accurate technique for identifying patients with RAS. It is less sensitive in picking up accessory renal arteries. Received: 17 March 1998; Revision received: 30 June 1998; Accepted: 28 August 1998  相似文献   

14.
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.  相似文献   

15.
Carotid stenosis: a comparison between MR and spiral CT angiography   总被引:9,自引:2,他引:7  
We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. Received: 8 August 1997 Accepted: 10 October 1997  相似文献   

16.
目的评估透视触发和并行采集技术用于高分辨率三维增强颈动脉磁共振血管成像术(3DCEMRA)的可行性。方法80个临床诊断或怀疑颈动脉狭窄的病人接受3DCEMRA检查。使用透视触发软件触发启动颈动脉3DCEMRA扫描,同时采用K空间椭圆形中心填充法和加速因子为2的并行采集技术。对显示的各段动脉和有无静脉早期显影做分析。动脉狭窄分成动脉管壁不规则、轻度狭窄、严重狭窄和闭塞。颈动脉3DCEMRA的显示结果与其他检查结果做了对照。结果所有病例均顺利触发和完成颈动脉3DCEMRA检查。3DCEMRA显示了80例病人总共800支动脉段(100%显示率),所有病例在动脉显示区域内静脉均未显影或显影很淡,对诊断不构成影响。结果显示有680段动脉正常、41段动脉管壁不规则、24段动脉轻度狭窄、51段严重狭窄和4段闭塞。另外10段颈动脉狭窄处溃疡形成,12例患者除见颈动脉狭窄以外,还发现合并椎动脉和/或锁骨下动脉狭窄。36例病例,与其他血管成像技术作了比较,3DCEMRA的检查结果与之完全符合,未出现高估或低估血管狭窄程度。结论透视触发并行采集高分辨率3DCEMRA简单可行,成像时间短,空间分辨率高,能清楚显示颈动脉,它将在颈动脉狭窄的诊断中起重要作用。  相似文献   

17.
PURPOSE: This study prospectively compares Doppler ultrasound (Doppler US) and contrast-enhanced magnetic resonance angiography (CE-MRA) with digital subtraction angiography (DSA) and endarterectomy findings to determine the accuracy in assessing carotid artery stenosis. MATERIALS AND METHODS: Thirty-two patients underwent carotid endarterectomy, 21 studied with Doppler US, CE-MRA and DSA and 11 with Doppler US and CE-MRA. In 41 carotid arteries, the degree of stenosis was analysed with Doppler US and CE-MRA and compared with DSA by using the Spearman rank correlation coefficient. Nine out of 32 endarterectomies were done using the eversion technique, and it was possible to compare Doppler US, CE-MRA and DSA with the specimen measurement. Twenty-three out of 32 endarterectomies were done using the standard technique, and the presence of ulcers was documented. RESULTS: There was a significant Doppler US/DSA (Rs=0.86; p<0.001) and CE-MRA/DSA (Rs=0.81; p<0.001) correlation for the degree of stenosis. The diagnostic accuracy of the three methods was the same (89%). Ulcers were most frequently seen at CE-MRA, with a diagnostic accuracy of 85%. CONCLUSIONS: These data suggest that endarterectomy on the basis of Doppler US and CE-MRA can be considered appropriate. CEMRA was the best noninvasive imaging modality to detect plaque ulceration.  相似文献   

18.
AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.  相似文献   

19.
颅颈部动脉狭窄的增强 MRA与DSA比较研究   总被引:7,自引:0,他引:7  
目的 评价椭圆形中心K空间编码增强(CE)MRA在颅颈部动脉狭窄性疾病的诊断价值.方法 48例根据临床症状怀疑有颅颈部动脉狭窄患者接受了CE MRA和DSA检查.MRA图像采用MIP、MPR方法重建,范围包含从主动脉弓部到Willis 环的所有的血管.以DSA为标准,MRA和DSA结果通过统计相关系数比较.结果 以是否狭窄为评判点时,MRA和DSA在各段颅颈部动脉取得较好的一致性.以狭窄程度超过70%为评判点时,MRA和DSA在颈动脉部位取得相当高的一致性.CE MRA显示椎-基底动脉,颈动脉终末段,颅内血管方面稍差.结论 椭圆形中心K空间编码CE MRA能有效地筛选出颅颈部动脉狭窄性病变.在颅外颈动脉部位可使大部分患者免于接受DSA检查.在诊断椎-基底动脉,颈动脉终末段,颅内血管狭窄方面的准确度不够,不能替代传统DSA检查.  相似文献   

20.
A contrast-enhanced, gradient-echo 3D pulse sequence providing angiographic information in 24 s was tested in five healthy subjects and used prospectively in 21 patients for the investigation of the cervical arteries. Indications included suspected stenosis of the carotid (in 13), or vertebral arteries (in 1), carotid dissection (3), variants of the branches of the aortic arch (2) and extracranial carotid aneurysms (2). The results in all patients were compared with those of intra-arterial digital subtraction angiography (DSA). In patients with carotid stenosis, they were also compared with high-resolution 3D time-of-flight (TOF) MR angiography (MRA). Good quality MR angiograms of the neck vessels were obtained with the fast 3D sequence in 20 of the 21 patients. One claustrophobic patient was unable to co-operate. The degree of internal carotid artery (ICA) stenosis was graded correctly (compared to DSA) in 21 of 24 cases (87.5 %). Two mild stenoses were overestimated as moderate using the fast MR sequence and one high-grade stenosis was misdiagnosed as a complete occlusion. Carotid dissection was confirmed in one case and correctly excluded in two. Four extracranial ICA aneurysms in two patients, arterial variants and stenosis of the origin of the vertebral artery were correctly diagnosed using the contrast-enhanced MR angiogram. Three-dimensional TOF MRA was unsuccessful due to motion artefacts in half of the cases of ICA stenosis. Received: 6 August 1998 Accepted: 21 December 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号