Background

Modern ceramic-on-ceramic bearings have become attractive alternatives to conventional polyethylene in total hip arthroplasty (THA) as a result of their low wear and minimal particle production. However, 28-mm heads in ceramic-on-ceramic bearing couples have been associated with ceramic fracture. To address these issues, 32-mm and larger ceramic heads with a titanium-alloy sleeve have been introduced, although limited data are available on their durability and clinical outcomes.

Questions/purposes

We determined (1) the survivorship of the primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve at a minimum followup of 5 years; (2) Harris hip scores; (3) the incidence of ceramic fracture and noisy hip; and (4) the proportion of hips showing radiographic evidence of osteolysis.

Methods

From November 2005 to August 2009, we performed 301 ceramic-on-ceramic THAs using a 32-mm ceramic head with a titanium-alloy sleeve in 270 patients. Of these, 12 patients (12 hips [4%]) died from problems unrelated to surgery and 13 patients (15 hips [5%]) were lost during followup before a minimum of 5 years had been reached, leaving 245 patients who had 274 THAs with a minimum followup of 5 years (mean, 6.5 years; range, 5–9 years) in this retrospective analysis. During the study period, 30% (301 of 997 hips) were performed with this articulation based on the operating surgeon’s discretion. The mean patient age at the time of surgery was 55 years (range, 16–82 years). All operations were performed at a single center. All of the ceramic implants were hot isostatic-pressed, laser-marked, proof-tested third-generation alumina. We determined the implant survival, Harris hip scores, incidence of ceramic fracture or noisy hips (based on a questionnaire), and presence of osteolysis.

Results

The survival rate of ceramic-on-ceramic bearings in primary THA using a 32-mm ceramic head with a titanium-alloy sleeve was 98% (95% confidence interval, 96%–100%) at 9 years. The Harris hip score improved from a mean of 47 points preoperatively to 93 points at last followup. One ceramic head fractured at 6 years postoperatively. No ceramic liners fractured. Audible hip clicking and squeaking were identified in four hips and one hip, respectively. Osteolysis was detected in three hips, but none had symptoms.

Conclusions

Primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve has a survivorship of 98% at 9-year followup. Nevertheless, surgeons should be aware of the potential risks of ceramic fracture, noise, and osteolysis associated with the use of a ceramic head with a titanium-alloy sleeve.

Level of Evidence

Level IV, therapeutic study.  相似文献   

2.
目的探讨现代陶对陶界面人工髋关节术后早期脱位的发生率和影响因素。方法回顾性分析我院骨科2009年6月至2012年12月间行陶对陶的人工髋关节置换术患者192例(212髋)的资料,其中初次行人工髋关节置换术175例(195髋),人工髋关节翻修17例(17髋),从股骨头假体的大小和所采用的手术入路以及髋臼的方位三方面,分析对人工髋关节置换术后发生脱位的影响。结果本组患者平均随访28个月(3~42个月),术后脱位率为0.47%(1/212),其中初次全髋关节置换术(totalhiparthroplasty,THA)术后脱位率为0,翻修THA术后脱位率为5.89%(1/17);无骨溶解,无假体松动,无陶瓷破裂等其他并发症。结论现代陶对陶界面THA采用大直径的股骨头、改良Hardinge入路且髋臼位置恰当,可降低人工髋关节置换术后的脱位率。  相似文献   

3.
4.
Ceramic-on-ceramic bearings in THA are a popular alternative to overcome wear concerns in traditional metal-polyethylene bearings. However, squeaking is a potentially worrisome phenomenon in ceramic-on-ceramic THAs which we observed in some of our patients. We reviewed all 42 patients who underwent 43 ceramic-on-ceramic noncemented THAs during the time of the study. Squeaking, defined as a reproducible sound of squeaking, clicking, or grating, occurred in nine of 43 implants (20.9%). Standard radiographs were normal. We used CT imaging to determine cup anteversion and inclination angles, comparing the squeaking hips with those of a randomly selected control group, but found no differences. We then hypothesized specific design features (stem size, cup size, head size, and neck length of the head) would be risk factors for squeaking. We found a difference in neck length between squeaking and nonsqueaking implants. A neck length of −4 mm or shorter resulted in a relative risk of 5.56 (95% confidence interval, 1.14–27.01) for squeaking. We found a high incidence of squeaking in our population, and we believe this phenomenon is an underreported side effect of these types of bearings. A short neck length of the femoral implant was a risk factor for squeaking in ceramic-on-ceramic THA. Level of Evidence: Level III, therapeutic study. Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article. Each author certifies that his or her institution has approved or waived approval for the human protocol for this investigation and that all investigations were conducted in conformity with ethical principles of research.  相似文献   

5.
《The Journal of arthroplasty》2020,35(11):3188-3194
BackgroundGeriatric femoral neck fracture is a common injury for which hemiarthroplasty (HA) or total hip arthroplasty (THA) may be considered in select patients. As prior database studies comparing these have not used propensity matching, which is a robust statistical method of controlling for potentially confounding variables, unmatched and matched methodologies are contrasted in the present study.MethodsPatients aged ≥70 years who underwent HA or THA for hip fractures were identified from the 2012-2015 National Surgical Quality Improvement database. Propensity score 1:1 matching was performed. Differences in rates of 30-day postoperative adverse outcomes were compared using multivariate logistic regression for unmatched and matched cohorts.ResultsIn total, 15,558 patients (14,403 HA and 1155 THA) were evaluated. Although multivariate outcomes for the unmatched populations were different for blood transfusion, mortality, minor adverse events, major adverse events, and reoperation, multivariate outcomes for matched populations only differed for blood transfusion (odds ratio 0.6 for HA vs THA, P < .001). Of note, although readmissions were similar for the two groups, patients undergoing THA had a 5.4% greater rate of perioperative readmission due to dislocation.ConclusionGeriatric patients undergoing HA and THA for hip fracture were compared with and without propensity matching. Once matching was performed, the only differences in outcomes between the two groups were a lower transfusion rate among the HA group and a greater readmission rate due to dislocation among the THA group. This suggests that either procedure can be safely considered if found to be advantageous from a longer-term outcome perspective.Level of EvidenceLevel III, retrospective comparative study.  相似文献   

6.
《The Journal of arthroplasty》2020,35(5):1412-1416
BackgroundIn cases of total hip arthroplasty (THA) dislocation, a synovial fluid aspiration is often performed to evaluate for periprosthetic joint infection (PJI). It is currently unclear how aseptic dislocation of a THA influences synovial fluid white blood cell (WBC) count and polymorphonuclear percentage (PMN%). The primary aim of this study is to investigate the influence of THA dislocation on synovial WBC count and PMN%.MethodsTwenty-eight patients who underwent a synovial aspiration of a THA between 2014 and 2019 were identified and enrolled in our case-control study. Patients with an aseptic THA dislocation and synovial hip aspiration were matched against patients without dislocation, patients undergoing hip aspiration before aseptic THA revision surgery, and patients undergoing hip aspiration before septic THA revision surgery.ResultsSynovial WBC count was significantly increased in the dislocation vs aseptic THA revision group (P = .015), as well as between the septic revision group vs dislocation and aseptic THA revision group (both P < .001). The PMN% did not differ significantly between the dislocation and aseptic revision groups (P = .294). Mean C-reactive protein values were 12.4 ± 14.9 mg/dL in THA dislocation, 24.1 ± 37.7 mg/dL in THA without infection compared to 85.7 ± 84.9 mg/dL in THA infection group (P < .001).ConclusionThis study shows that THA dislocation has a significant impact on synovial WBC count in joint aspiration. Our data suggest that in the setting of THA dislocation, synovial WBC and PMN% may not be the best method to evaluate for PJI. Further research should be performed to establish new thresholds for these synovial inflammatory markers in the setting of THA dislocation and PJI.Level of evidenceLevel III; retrospective trial.  相似文献   

7.
BackgroundImmobility of the lumbar spine predicts instability following elective total hip arthroplasty (THA). The purpose of this study is to determine how prior lumbar fusion (LF) influenced dislocation rates and revision rates for patients undergoing THA or hemiarthroplasty (HA) for femoral neck fracture (FNF).MethodsA retrospective cohort analysis was conducted utilizing the PearlDiver database from 2010 to 2018. Patients who underwent arthroplasty for FNF were identified based on history of LF and whether they underwent THA or HA. Univariate and multivariate analyses were performed.ResultsA total of 328 patients with prior LF and FNF who underwent THA were at increased risk for 1-year dislocation (odds ratio [OR] 2.19, P < .001) and 2-year revision (OR 2.22, P < .001) compared to 14,217 patients without LF. The 461 patients with prior LF and FNF who underwent HA were at increased risk for dislocation (OR 2.22, P < .001) compared to 42,327 patients without LF. Patients with prior LF and FNF who underwent THA had higher rates of revision than patients with prior LF who underwent HA for FNF (OR 2.11, P < .001). In patients with prior LF and FNF, THA was associated with significantly increased risk for dislocation (OR 3.07, P < .001) and revision (OR 2.53, P < .001) compared to THA performed for osteoarthritis.ConclusionPatients with prior LF who sustained an FNF and underwent THA or HA were at increased risk for early dislocation and revision compared to those without prior LF. This risk of dislocation and revision is even greater than that observed in patients with prior LF who underwent THA for osteoarthritis.Level of EvidenceLevel III.  相似文献   

8.
BackgroundAdult patients with cerebral palsy (CP), who have advanced degenerative arthritis of the hip, have been treated with resection arthroplasty and arthrodesis. Although total hip arthroplasty (THA) has also been used as one of the alternative options, there are few studies on contemporary bearings used in THA. Therefore, we evaluated the results of the contemporary ceramic-on-ceramic THA in adult patients with CP.MethodsFrom January 2005 to December 2007, five adult CP patients (5 hips) underwent THA using contemporary ceramic-on-ceramic bearings. All patients were able to stand or ambulate with intermittent use of assistive devices at home. We retrospectively reviewed the series to determine the results of THA in terms of pain relief, improved function, and durability of prosthesis.ResultsThere were 3 men and 2 women with a mean age of 35.9 years. All patients had pain relief without decline in mobility postoperatively. One hip was dislocated, which was treated successfully with closed reduction and an abduction brace for 2 months. There was no ceramic fracture, loosening, or osteolysis during the mean follow-up of 6.8 years (range, 5.8 to 8.3 years).ConclusionsCementless THA using contemporary ceramic-on-ceramic bearings is a useful option for the treatment of advanced degenerative arthritis of the hip in ambulatory adults with CP.  相似文献   

9.

Background

Dislocation is a common complication after total hip arthroplasty (THA). Although the etiology of dislocation is multifactorial, longer-term changes in muscle such as atrophy may influence the risk of prosthetic dislocation. Biological differences in wear products generated by different bearing surfaces may influence differences in the appearance of periarticular muscle after THA; however, such bearing-associated differences to our knowledge have not been studied in vivo, and few studies have evaluated bearing-associated differences in dislocation risk.

Questions/purposes

(1) Is there a correlation between the postoperative risk of dislocation at revision and the bearing surfaces of the primary arthroplasty? (2) Is there a higher extent of fatty muscle atrophy on CT scan in hips with osteolysis (polyethylene hips) as compared with hips without osteolysis (ceramic-on-ceramic hips)? (3) Are these two abnormalities (bone osteolysis and fatty atrophy) associated with a decrease of mesenchymal stem cells (MSCs) in bone and in muscle?

Methods

We retrospectively evaluated 240 patients (240 hips) who had a THA revision (98% of which, 235 of the 240, were isolated acetabular revisions) and a normal contralateral hip. All patients had received the same implants for the primary arthroplasty (32-mm head) except for bearing surfaces (80 hips with ceramic-on-ceramic, 160 with polyethylene). No differences were noted between the groups in terms of age, sex, body mass index, proportion of patients who had a dislocation after the index arthroplasty but before the revision, and proportion of the patients with stem loosening in addition to acetabular loosening. Indications for revision generally were cup loosening. The revisions in the hips with polyethylene bearings generally had more acetabular bone loss, but the position of the center of the cup and the orientation of the cup were similar after reconstruction in the two groups. Before revision, osteolysis, muscle atrophy, and fatty degeneration were evaluated on CT scan and compared with the contralateral side. Bone muscle progenitors were evaluated by bone marrow MSCs and satellite cells for muscle. At revision, all the hips received the same implants with the same head diameter (32 mm) and a standard liner. Revisions were performed between 1995 and 2005. The followup after revision was at a mean of 14 years (range, 10–20 years) for ceramic revision and 12 years (range, 10–20 years) for polyethylene hips, and there was no differential loss to followup between the groups.

Results

More hips with polyethylene liners at the time of index arthroplasty dislocated after revision than did hips with ceramic liners (18% [29 of 160] compared with 1% [one of 80]; odds ratio, 17.5; 95% confidence interval, 2.3363–130.9100; p = 0.005). For the 80 hips with ceramic-on-ceramic, no osteolysis was detected before revision; there was no muscle fatty degeneration of the gluteus muscles on CT scan or histology. For the 160 hips with polyethylene liners, osteolytic lesions on the acetabulum and femur were observed in 100% of the hips. The increased atrophy of the gluteus muscles observed on CT scan correlated with the increase of osteolysis (r = 0.62; p = 0.012). The surgical limbs in the patients with polyethylene hips as compared with ceramic-on-ceramic hips demonstrated a greater reduction in cross-sectional area (respectively, 11.6% compared with 3%; odds ratio, 3.82; p < 0.001) and radiological density (41% [14.1/34.1] compared with 9%; odds ratio, 6.8; p = 0.006) of gluteus muscles when compared with the contralateral normal side. (41% compared with 9%; odds ratio, 6.8; p = 0.006).

Conclusions

Ceramic bearing surfaces were associated with fewer dislocations after revision than polyethylene bearing surfaces. The reasons of the lower rate of dislocation with ceramic-on-ceramic bearings may be related to observed differences in the periarticular muscles (fat atrophy or not) with the two bearing surfaces.

Level of Evidence

Level III, therapeutic study.  相似文献   

10.
《The Journal of arthroplasty》2020,35(9):2573-2580
BackgroundAnkylosing spondylitis (AS) is a common inflammatory spondyloarthropathy with hip involvement in 40% of patients. With the recent interest in the hip-spine interplay, the purpose of this study was to define the long-term outcomes of revision total hip arthroplasty (THA) in the setting of AS.Methods174 hips in patients with AS treated with revision THA from 1969 to 2016 were identified. Mean age at revision THA was 53 years and 76% were male. Cumulative incidences of any re-revision, reoperation, and dislocation were calculated using a competing risk analysis. Mean follow-up was 13 years.ResultsThe cumulative incidence of any re-revision after index revision THA was 7% at 5 years and 36% at 20 years. Cumulative incidence of any reoperation was 9% at 5 years and 38% at 20 years. Cumulative incidence of dislocation was 6% at 5 years and 8% at 20 years. Revision THAs performed with contemporary implants (2000-2016) had a lower but statistically nonsignificant cumulative incidence of any re-revision when compared with historical implants (before 2000) at 5 years (5% vs 8%), 10 years (11% vs 18%), and 15 years (11% vs 38%) (hazard ratio, 0.47; 95% confidence interval, 0.17-1.33; P = .016).ConclusionIn this large series of 174 revision THAs in patients with AS, the cumulative incidence of dislocation was 8% at 20 years. The 20-year cumulative incidence of any re-revision was 36%, which is similar to reported rates in patients with comparable demographic features without AS.Level of EvidenceLevel IV.  相似文献   

11.

Background

Ceramic-on-ceramic bearing couples are theoretically attractive in total hip arthroplasty (THA) because of low wear, but concerns regarding ceramic fracture and squeaking have arisen. Improved material properties of newer alumina matrix composite (AMC) materials, known as Delta ceramics, may reduce these risks. In addition, the use of thinner liners and larger femoral heads may be helpful clinically to lower the rate of dislocation. However, limited short-term clinical results are available and intermediate-term effects are unclear.

Questions/purposes

(1) What is the frequency of bearing-related complications (dissociation, fracture, and noise) with ceramic-on-ceramic AMC bearings in cementless THA? (2) What other complications arose in patients treated with these bearings? (3) What are the Harris hip scores (HHS) and survivorship free from reoperation and revision at a minimum of 5 years after cementless THA performed with AMC bearings?

Methods

Over a 9-month period in 2009, one surgeon performed 125 THAs, of which 100 (80% of the total) were performed with cementless, AMC bearings. During the period in question, the exclusion criteria for this implant were primary THAs with severe acetabular or femoral bone defect and revision THAs. Of these, 94 hips (95%) in 91 patients were available for analysis at a minimum of 5 years (range, 5–6 years), because five patients (six hips) had died. Mean age at the time of arthroplasty was 55 ± 14 years. Prostheses with an identical design and Biolox® Delta ceramics were used in all patients. Noise was classified into squeaking, clicking, grinding, and popping. Ceramic fracture, dislocation, and any other complications associated with the use of AMC ceramics were also investigated. Clinical evaluation included the modified HHS preoperatively and at each followup. Survivorship free from reoperation and revision was calculated using the Kaplan-Meier method.

Results

Of 91 patients, four developed bearing-related complications, including one with liner dissociation despite initial square seating and three with clicking. No patients had ceramic fractures. A single event of perioperative dislocation occurred in one patient and postoperative periprosthetic fracture occurred in two hips. Mean HHS improved from 56 to 93 points at the final followup (p < 0.001). Survivorship at 5 years free from reoperation and revision was 96.8% and 97.9%, respectively.

Conclusions

Improved material properties combined with the possible use of larger diameter heads make AMC ceramics a promising alternative bearing option with seemingly comparable clinical outcomes reported by others with conventional ceramic bearings. Despite these encouraging results, however, meticulous technical precautions such as square seating and proper impaction in particular should be taken during liner insertion, because we did observe one liner dissociation and several patients with hip noises.

Level of Evidence

Level IV, therapeutic study.  相似文献   

12.
13.
14.
目的:比较陶对陶(ceramic-on-ceramic,COC)与陶对聚乙烯假体(ceramic-on-polyeth-ylene,COP)在全髋关节置换术中应用的可靠性和耐用性。方法对77例接受初次全髋关节置换的患者进行回顾性研究,比较 COC 与 COP 两种不同假体术后髋关节功能及并发症。结果COC组与 COP 组术后髋关节 Harris 评分分别为92.6±5.1和91.3±4.2,差异无统计学意义(P >0.05);两者在翻修、脱位、陶瓷破碎、异响、松动、骨溶解、深部感染、异化骨化发生率的比较,差异无统计学意义(P >0.05)。结论COC 与 COP 假体均能获得较好的临床疗效,两者术后在髋关节功能及并发症方面疗效相当。  相似文献   

15.
BackgroundMetal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA.MethodsThirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method.ResultsFluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans.ConclusionAsymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings.Level of EvidenceDiagnostic Level IV.  相似文献   

16.
BackgroundAs indications for elective total hip arthroplasty (THA) expand to younger patients, we sought to (1) compare revision risk following primary elective THA in patients <55 years at the time of their THA to patients aged ≥65 years and (2) identify specific risk factors for revision in patients <55 years.MethodsA Kaiser Permanente's total joint replacement registry was used to conduct a cohort study including primary elective THA patients aged ≥18 (2001-2018). In total, 11,671 patients <55 years and 53,106 patients ≥65 years were included. Multiple Cox regression was used to evaluate cause-specific revision risk, including septic revision, aseptic loosening, instability, and periprosthetic fracture. Stepwise Cox regression was used to identify patient and surgical factors associated with cause-specific revision in patients <55 years.ResultsPatients <55 years had a higher risk of septic revision (hazard ratio [HR] = 1.30, 95% confidence interval [CI] = 1.02-1.66), aseptic loosening (HR = 2.60, 95% CI = 1.99-3.40), and instability (HR = 1.35, 95% CI = 1.09-1.68), but a lower risk of revision for periprosthetic fracture (HR = 0.36, 95% CI = 0.22-0.59) compared to patients aged ≥65 years. In the <55 age group, risk factors for septic revision included higher body mass index, drug abuse, and liver disease. Hypertension, anterior approach, and ceramic-on-ceramic were associated with aseptic loosening. White race, American Society of Anesthesiologists classification ≥3, smoker, paralysis, posterior approach, ceramic-on-ceramic, and smaller head diameter were associated with instability.ConclusionIdentified risk factors varied depending on the cause for revision. Although septic revisions were related to patient characteristics, more modifiable factors, such as implant or surgical approach, were associated with revision due to aseptic loosening and instability.Level of EvidenceIII.  相似文献   

17.
18.
Ceramics have been used as a bearing surface in total hip arthroplasty (THA) for more than 30 years. Properties of this material which make it particularly attractive for this application include its hardness, high compression strength, and excellent wettability. The low incidence of biologically significant particle generation and clinically significant osteolysis with the use of ceramics in THA reflects these properties. However, low fracture toughness and linear elastic behavior demonstrated by ceramic make it prone to breakage under stress. Improvements in the processing of ceramic as well as advances in engineering of head-neck articulations and liner design have led to an overall decrease in the incidence of ceramic fracture and dislocation. This article reviews the science behind the use of ceramics in THA, the clinical results of ceramics in THA, including complications unique to this bearing surface, and future directions for the application of ceramics in THA.  相似文献   

19.
Current updated meta-analysis was designed to compare clinical effects of hemiarthroplasty (HA) vs primary total hip arthroplasty (THA) for displaced femoral neck fractures in elderly patients. Five randomized and 4 quasi-randomized controlled trials with a total 1208 patients were included for final analysis. It showed that mortality and postoperative infection between HA and THA had no statistical differences, that long-term reoperation rate of HA was higher than that of THA, that medium-term dislocation rate of HA was lower than that of THA, and that pain rates of HA in short-term and long-term were both higher than THA. Summarily, treatment of THA for elderly displaced femoral neck fracture could provide better results of reduced reoperation rate and pain relief; however, HA yielded a lower incidence of postoperative dislocation.  相似文献   

20.
BackgroundAlumina ceramic-on-ceramic bearings are used in total hip arthroplasty (THA) because of their wear-resistant and inert properties. In this study, we assessed the clinical and radiographic outcomes of patients undergoing primary cementless ceramic-on-ceramic THA at a minimum follow-up of 20 years.MethodsA series of 301 consecutive primary THAs in 283 patients were assessed. Clinically, patients were assessed with the modified Harris Hip Score (HHS) and pain questionnaires. Anteroposterior radiographs of the pelvis and lateral radiographs of the hip were used to radiologically assess the implant. Patients were classified as lost to follow-up if they could not be contacted on multiple occasions or did not wish to participate further in this study.ResultsAt twenty years after operation, 60 patients had died of a cause unrelated to surgery, 16 had experienced complications requiring reoperation, and 100 hips had both clinical assessments and radiographs at a minimum of 20 years of follow-up. The average HHS improved from 56.1 (range: 17-89) before THA to 92.5 (range: 63-100) at the latest follow-up. The classification of the HHS was good or excellent in 96.4% of patients. Only 1.8% of patients still had moderate residual pain at the thigh or groin. Radiographically, all patients demonstrated bony ingrowth but no clinical symptoms of loosening. The overall survival rate of the implants was 94.2% at 20 years with revision for any reason as the end point.ConclusionLong-Term follow-up in our series showed excellent implant survival, excellent functional outcomes, and minimal late complications. There was no significant radiographic evidence of failure at a minimum of 20 years after THA.Level of evidenceTherapeutic Level IV.  相似文献   