首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Xu H  Lee CY  Clemens MG  Zhang JX 《Transplantation》2004,77(11):1676-1682
BACKGROUND: Although hypothermic machine perfusion (HMP) preservation has been shown to improve organ function and to expand the organ donor pool, problems still exist with the current HMP technology for liver preservation. The present study was conducted to investigate endothelial and hepatocellular functions following extended HMP (> r =24 hr) in rat liver model. METHODS: Following 24-hour hypothermic HMP with University of Wisconsin (UW) solution or 24-hour simple cold storage (SCS), livers were reperfused with Krebs-Henseleit buffer solution at 37 degree C for 30 minutes. Hepatocyte damage and function were assessed by measuring lactate dehydrogenase (LDH) activity, bile production, and indocyanine green (ICG) extraction. Sinusoidal endothelial cell (SEC) function and permeability were determined by hyaluronic acid (HA) uptake and multiple indicator dilution (MID) method, respectively. RESULTS: After 24-hour hypothermic preservation, HMP livers showed lower released LDH levels, higher bile flow rate, and greater hepatic ICG uptake compared with SCS livers. However, LDH levels became significantly higher in HMP than in SCS after 30 minutes of warm perfusion. The increased enzyme levels were accompanied by a significant increase in endothelial permeability to albumin and a decrease in hyaluronic acid uptake in HMP compared to SCS. Liver wet/dry weight ratio confirmed a greater edema in HMP livers than SCS livers. CONCLUSION: These results suggest that 24-hour hypothermic HMP may help preservation of hepatocyte function, but endothelial cell dysfunction during the cold preservation may play a key role in hepatocyte dysfunction and parenchymal cell death upon reperfusion.  相似文献   

2.
Hypothermic machine perfusion (HMP) provides better protection against cold ischemic injury than cold storage in marginal donor kidneys. Also, in liver transplantation a switch from static cold storage to HMP could be beneficial as it would allow longer preservation times and the use of marginal donors. A critical question concerning application of HMP in liver preservation is the crucial balance between perfusion pressure and occurrence of endothelial injury. Rat livers were cold-perfused for 24 hours to study perfusion pressures for both hepatic artery and portal vein. Cold storage served as control and was compared to HMP-preserved livers using a mean arterial perfusion pressure of 25 mm Hg and a portal perfusion pressure of 4 mm Hg (25% of normothermic liver circulation) and to HMP at 50 mm Hg and 8 mm Hg perfusion, respectively (50% of normothermic liver circulation). UW solution was enriched with 14.9 micromol/L propidium iodide (PI) to stain for dead cells and with an additional 13.5 micromol/L acridine orange to stain for viable hepatocytes. A low PI-positive cell count was found using HMP at 25% of normal circulation compared to cold storage. The PI count was high for the HMP group perfused at just 50% of normal circulation compared to HMP at 25% and compared to cold storage. In summary, for liver HMP, perfusion at 25% showed complete perfusion with minimal cellular injury. HMP using perfusion pressures of 25 mm Hg for the hepatic artery and 4 mm Hg for the portal vein is feasible without induction of endothelial injury.  相似文献   

3.
BACKGROUND: Non-heart-beating donor (NHBD) livers are an untapped source with the potential to provide relief to the current donor shortage problem. Hypothermic machine perfusion (MP) has the potential to reclaim and preserve these marginal donor organs. METHODS: This study compared 5-day survival in a rat NHBD liver transplantation model with simple cold storage (SCS) and MP-preserved tissues that had experienced 30 min of warm ischemia followed by a 5-hr preservation period with the University of Wisconsin solution. Total release of lactate dehydrogenase (LDH) and alanine aminotransferase (ALT) were determined at major time points. Bilirubin levels and histology were examined after 5-day survival. RESULTS: Six of seven control livers and five of six MP livers survived, whereas SCS tissues had survival in zero of seven. The results showed that MP livers had reduced release of LDH and ALT after 5 hr of storage, 5.07+/-1.42 and 2.02+/-0.69 U (mean+/-SE), respectively, compared with SCS, 15.54+/-0.81 and 3.41.3+/-0.73 U, respectively. Bilirubin values after 5-day survival of MP livers (1.17+/-0.49 mg/dL) were comparable to controls (0.91+/-0.36 mg/dL). Histology confirms that SCS displayed increased necrosis and MP tissue showed regions of near normal hepatic structure. CONCLUSIONS: These results suggest that MP for 5 hr improves survival and reduces cellular damage of liver tissue that has experienced 30 min of warm ischemia when compared with SCS tissues. Further studies need to be conducted, but this study suggests that MP preservation has the potential to reclaim and preserve NHBD liver tissues.  相似文献   

4.
5.
Abstract We investigated the effect of oxygen supply on hepatic cellular viability during cold perfusion storage of rat livers- A perfluoro- N -methyldecahydroisoquinoline (FMIQ) emulsion is used as an oxygen carrier. The composition of the perfusate containing 20 w/v% FMIQ is essentially the same as the University of Wisconsin (UW) solution except for the exclusion of hydroxyethyl starch. Rat livers were perfused at 4°C for up to 24 h with either UW solution (group I, oxygenated; group II, unoxygenated) or FMIQ solution (group III, oxygenated; group IV, unoxygenated). After perfusion storage, the livers were reperfused with warm (37 °C) oxygenated or cold (4 °C) unoxygenated Krebs-Henseleit bicarbonate buffer, and nuclear trypan blue uptake was measured as the index of cell death. With warm oxygenated reperfusion, there remained less than 2% noviable parenchymal cells up to 24 h, regardless of perfusate or oxygenation. In UW-perfused livers, the proportion of nonviable nonprenchymal cells (NPC) increased progressively regardless of oxygenation, the values in groups I and II in the periportal field at 24 h being 39.9 ± 4.7% (mean ± SD) and 36.5 ± 4.2%, respectively. By contrast, in FMIQ-perfused livers, dye uptake by NPC was significantly reduced with oxygenation (16.9 ± 5.7% and 39.4%± 9.1% at 24 h in groups III and IV; P < 0.001). With cold unoxygenated reperfusion, livers in groups I, II, and IV showed a significant decrease of nonviable NPC, while those in group III showed no significant changes. These data indicate that oxygen supply during perfusion storage of the liver may ameliorate lethal injury to NPC precipitated during reperfusion.  相似文献   

6.
7.
BACKGROUND: Non-heart-beating donor (NHBD) livers represent an important organ pool, but are seldom utilized clinically and require rapid retrieval and implantation. Experimental work with oxygenated perfusion during preservation has shown promising results by recovering function in these livers. This study compared sanguinous perfusion with cold storage for extended preservation of the NHBD liver in a porcine model. METHODS: Porcine livers were subjected to 60 min of in vivo total warm ischaemia before flushing, after which they were preserved by one of two methods: group 1 (n = 4), University of Wisconsin (UW) solution by standard cold storage for 24 h; group 2 (n = 4), oxygenated autologous blood perfusion on an extracorporeal circuit for 24 h. All livers were subsequently tested on the circuit during a 24-h reperfusion phase. RESULTS: Livers in group 1 showed no evidence of viability during the reperfusion phase with no bile production or glucose utilization; they also displayed massive necrosis. Livers in group 2 demonstrated recovery of function by synthetic function, substrate utilization and perfusion haemodynamics; these livers displayed less cellular injury by hepatocellular enzymes. All differences in parameters between the two groups were statistically significant (P < 0.05). These findings were supported by histological examination. CONCLUSION: Warm ischaemia for 1 h and simple cold storage (UW solution) for 24 h renders the liver non-viable. Oxygenated, sanguinous perfusion as a method of preservation recovers liver function to a viable level after 24 h of preservation.  相似文献   

8.
9.
Hypothermic machine perfusion (HMP) has a potential to relieve the current donor liver crisis by providing an improved and extended preservation method. This study examined the effect of HMP on hepatocellular functions, using a prototype liver transporter capable of preserving livers for 24 hours. Livers obtained from adult farm pigs (28 to 32 kg body weight) were divided into three groups: fresh control, HMP, and simple cold storage (n = 4 each). A 4-hour normothermic reperfusion of livers was conducted to assess hepato-metabolic and cellular functions. The hepatic transport function, as indicated by canalicular excretion of indocyanine green, was improved in the HMP group than in the SCS group. The overall tissue viability, as indicated by oxygen consumption levels, was notably improved in HMP and control livers as compared to the SCS group. Higher bile production in both the preserved groups as compared to the fresh control livers could be a result of biliary edema and leakage of plasma into the canaliculus. The hepato-cellular injury, measured by ALT, release was significantly greater in the SCS group as compared to the HMP and control groups. These findings suggest that HMP could be a better method to preserve hepatic function and overall tissue viability as compared to SCS. Improved hepatic functions are indirect indicators of superior microcirculation and sinusoidal endothelial cell functions. Further studies in progress will evaluate these functions to confirm the significance of these observations.  相似文献   

10.
11.
12.

Background

Livers originating from donation after circulatory death (DCD) donors are exposed to warm ischemia (WI) before liver transplantation (LTx). Currently, there are no objective tests to evaluate the damage sustained before LTx. This study aims to identify surrogate markers for liver injury that can be assessed during hypothermic machine perfusion (HMP) preservation. In addition, we want to use mathematical equation modeling combining these markers to improve our assessment of DCD livers for transplantation.

Materials and methods

Porcine livers were exposed to incremental periods of WI (0–120 min) and subsequently HMP preserved for 4 h. Biochemical and hemodynamic parameters were repeatedly measured in the perfusate during HMP. Subsequently, to mimic LTx, normothermic isolated-liver perfusion was applied for 2 h and the injury assessed using a morphological score.

Results

With increasing WI periods, the perfusate became more acidotic, and levels of aspartate aminotransferase (AST), liver fatty acid binding protein, redox-active iron, and arterial vascular resistance increased. A damage index, combining AST and pH (damage index = 2 − 37 × βAST − 257 × βpH) based on multifactorial analysis of the changing pattern of these markers, had increased sensitivity and specificity to reflect WI and reperfusion injury.

Conclusions

This proof of concept study demonstrated the potential role for objective evaluation of DCD porcine livers during HMP and the advantage to use multifactorial analysis on the markers' changing pattern.  相似文献   

13.
BACKGROUND AND METHODS: The aim of this study was to evaluate the efficacy of hypothermic machine perfusion (HMP) to preserve rat livers according to the route of perfusion, i.e., via portal vein, hepatic veins (retrograde), or hepatic artery. Livers were preserved for 24 or 48 hr by simple cold storage (SCS) or by HMP. Preservation solution was supplemented with (HMP) or without (SCS) hydroxyethyl starch. After preservation, grafts were reperfused for 2 hr with an oxygenated Krebs-Henseleit bicarbonate buffer. RESULTS: After 24 hr of preservation, total glutathione concentrations in HMP livers were similar (1287+/-37, 1418+/-118, and 1471+/-62 nmol/g in hepatic artery, portal vein, and hepatic vein HMP livers, respectively) and higher than in the SCS (833+/-118 nmol/g, P<0.05) group. These higher total glutathione values were due to higher reduced glutathione concentrations. ATP concentrations in the liver tissue were similar in HMP groups (0.75+/-0.4, 0.64+/-0.1, and 0.77+/-0.1 micromol/g in hepatic artery, portal vein, and hepatic vein HMP livers, respectively) and higher than in SCS (0.32+/-0.06 micromol/g, P<0.05). After 2 hr of normothermic reperfusion, bile production in the HMP portal and HMP retrograde groups were similar (391+/-29 ml and 372+/-25 ml) and higher than in the HMP artery or SCS groups (275+/-25 ml and 277+/-32 ml, respectively; P<0.05). Aspartate transaminase, alanine transaminase, lactate dehydrogenase, and purine nucleoside phosphorylase release into the perfusate of HMP portal and HMP retrograde perfused livers was similar and significantly lower compared to the HMP artery and SCS groups. At the end of reperfusion, no statistical differences were found for glutathione concentration and energetic reserves in the livers of each group. After 48 hr of preservation, livers from the HMP portal and HMP retrograde groups did significantly better than livers from the HMP artery or SCS groups. CONCLUSIONS: This study confirms the superiority of HMP over SCS to preserve the liver graft. It shows that retrograde perfusion is similar to PV perfusion and that perfusion by HA is less beneficial.  相似文献   

14.
The number of heart transplants is decreasing due to organ shortage, yet the donor pool could be enlarged by improving graft preservation. Hypothermic machine perfusion (MP) has been shown to improve kidney, liver, or lung graft preservation. Sixteen pig hearts were recovered following cardioplegia and randomized to two different groups of 4‐hour preservation using either static cold storage (CS) or MP (Modified LifePort© System, Organ Recovery Systems©, Itasca, Il). The grafts then underwent reperfusion on a Langendorff for 60 min. Energetic metabolism was quantified at baseline, postpreservation, and postreperfusion by measuring lactate and high‐energy phosphates. The contractility index (CI) was assessed both in vivo prior to cardioplegia and during reperfusion. Following reperfusion, the hearts preserved using CS exhibited higher lactate levels (56.63 ± 23.57 vs. 11.25 ± 3.92 μmol/g; < 0.001), increased adenosine monophosphate/adenosine triphosphate (AMP/ATP) ratio (0.4 ± 0.23 vs. 0.04 ± 0.04; P < 0.001), and lower phosphocreatine/creatine (PCr/Cr) ratio (33.5 ± 12.6 vs. 55.3 ± 5.8; P <0.001). Coronary flow was similar in both groups during reperfusion (107 ± 9 vs. 125 + /‐9 ml/100 g/min heart; P = ns). CI decreased in the CS group, yet being well‐preserved in the MP group. Compared with CS, MP resulted in improved preservation of the energy state and more successful functional recovery of heart graft.  相似文献   

15.
16.
The isolated perfused rat liver (IPRL) has been used to evaluate various aspects of hepatic metabolism. However, varying perfusion compositions, specifically differing concentrations of erythrocytes (RBC), make comparisons difficult. We evaluated oxygen and glucose consumption, sodium and potassium release, and hepatic enzyme release in rat livers perfused with either cell-free (CF) or 10% RBC-containing perfusates for 90 min. Perfusate oxygen content and hepatic oxygen consumption were increased in RBC vs CF perfusion (VO2 = 0.0208 ± 0.002 (RBC) vs 0.0107 ± 0.001 (CF) ml O2/min/g). Glucose consumption was increased in CF perfusion (0.295 ± 0.048 (CF) vs 0.173 ± 0.065 (RBC) mg/min/g). Sodium, potassium, and alkaline phosphatase release were not increased in either CF or RBC perfusion. SGOT and SGPT release occurred in both perfusion systems, although significantly greater elevations were documented by 75 min in CF perfusion. Bile flow was significantly elevated with RBC perfusion. High-power light microscopy and electron microscopy documented more cellular and subcellular injury in CF perfusion. We conclude that perfusion with 10% RBCs is associated with less cellular injury and enhanced oxygen delivery to the isolated perfused rat liver.  相似文献   

17.
18.
Hypothermic plasma perfusion of the isolated heart   总被引:1,自引:0,他引:1  
S Pitzele  S Sze  A R Dobell 《Surgery》1971,70(3):407-412
  相似文献   

19.
BACKGROUND: Neutrophil adhesion to endothelium contributes to myocardial reperfusion injury after cardiac operation. Initial neutrophil-endothelial interactions involve selectins, which bind Sialyl-LewisX on neutrophils. Blockade of selectin-mediated neutrophil-endothelial interactions with CY-1503, a synthetic analogue of Sialyl-LewisX, might reduce reperfusion injury after myocardial ischemia. METHODS: The efficacy of CY-1503 to attenuate global myocardial reperfusion injury was assessed in isolated blood-perfused neonatal lamb hearts that had 2 hours of cold cardioplegic ischemia. CY-1503 (40 mg/L) or saline vehicle was added to blood perfusate before ischemia. Contractile function (developed pressure, dP/dt) and coronary vascular endothelial function (acetylcholine response) were assessed at base line and during reperfusion. Myocardial neutrophil accumulation was assessed by myeloperoxidase quantification. RESULTS: Compared to controls, treatment with CY-1503 improved recovery of all indices of contractile function, preserved coronary vascular endothelial function, and reduced myocardial neutrophil accumulation. CONCLUSIONS: In isolated neonatal lamb hearts that underwent hypothermic cardioplegic ischemia, CY-1503 administration reduced myocardial neutrophil accumulation and preserved endothelial and contractile function. Selectin blockade of leukocyte-endothelial interactions might attenuate reperfusion injury and enhance myocardial protection during cardiac surgical procedures.  相似文献   

20.
BACKGROUND: Hypothermic machine perfusion preservation has the potential to relieve the current donor shortage problem by reclaiming and preserving marginal donor organs including those from viable non-heart-beating donors. A number of problems exist with the current machine perfusion technology for preserving livers, and much research is needed to determine the clinical impact of this technology in preserving non-heart-beating donor livers. METHODS: This study was conducted to compare the poststorage function and microcirculation of simple cold stored and machine perfusion preserved livers that had experienced 30 min of warm ischemia followed by a 10 hr preservation period. In an isolated rat liver perfusion model, lactate dehydrogenase activity, indocyanine green secretion, and portal pressure values were determined at major time points. An intravital microscopy was conducted to assess microcirculation. RESULTS: The results showed an increase in flow homogeneity of machine perfused livers, which correlated with the reduction in portal pressure when compared with simple cold storage (5.4+/-0.4 vs. 8.7+/-0.6 mm Hg). A reduction in lactate dehydrogenase levels in the perfusate (333+/-22 vs.103+/-8 U/L) and an increase in bile production of the machine perfused livers (4.9+/-0.5 vs. 33.2+/-1.7 microg/min/g liver) and indocyanine green secretion (11.7+/-1.7 vs. 21.2+/-2.1 Abs/g bile) were observed at all time points (mean+/-SE of final point given). Intravital microscopic examination indicated that large regions of non flow, as indicated by the absence of fluorescein isothiocyanate-labeled albumin, were observed in the simple cold stored tissue, whereas machine perfused liver showed increase flow homogeneity. Values of bile production, indocyanine secretion, and cellular damages were comparable with controls. Histologic examination confirmed that simple cold stored tissue displayed increased vacuolization, and machine perfused tissue showed regions of normal hepatic structure. CONCLUSION: These results suggest that machine perfusion for 10 hr improves both poststorage function and microcirculation while reducing cellular damage of liver tissue that has experienced 30 min of warm ischemia, when compared with simple cold storage. Further studies need to be conducted, but this study suggests that machine perfusion preservation has the potential to reclaim and preserve liver tissues after warm ischemic insult.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号