BACKGROUND AND AIM OF THE STUDY: Concern exists regarding progressive root dilatation after the modified Ross procedure. The present prospective echocardiographic study aimed to provide further insight into neo-aortic regurgitation (nAR) and neoaortic root dimensions over time in adult Rotterdam Ross root patients, and to study potential risk factors for nAR and dilatation. METHODS: All Rotterdam Ross patients aged > or = 16 years at surgery were subjected to a prospective biennial standardized echocardiographic protocol. Analysis over time of nAR according to the jet length and jet diameter method, autograft annulus and sinotubular junction (STJ) diameters was carried out using a multilevel linear model in 90 patients who had two or more echocardiographic measurements (mean 5; range 2-9; total 458) up to 14 years (mean 7 years) after surgery. RESULTS: The mean (+/- SE) initial postoperative jet length nAR was grade 0.9 +/- 0.09, and the annual increase 0.1 +/- 0.02 (p < 0.001). Initial annulus and STJ diameters were 25 +/- 0.5 mm and 36 +/- 0.6 mm, while annual increases were 0.4 +/- 0.07 mm and 0.5 +/- 0.09 mm, respectively (p < 0.001). Patients who eventually underwent an autograft reoperation (n = 10) had significantly greater initial nAR and greater progression of nAR, and a greater initial annulus diameter. The annual annulus and STJ diameter increase was greater in patients who underwent autograft reoperation. Compared to freestanding root replacement, patients with inclusion cylinder aortic root replacement had smaller initial annulus and STJ diameters that did not increase over time. Female gender was associated with a greater initial jet length and jet diameter nAR and a greater increase over time in jet diameter nAR. Preoperative aortic regurgitation or combined aortic stenosis and regurgitation were associated with greater initial annulus and STJ diameters. Neither bicuspid valve disease, patient age, preoperative ascending aorta aneurysm, prior aortic valve surgery nor hypertension had an effect on initial or progression of nAR, annulus, and STJ diameter. CONCLUSION: The annual increase in nAR and root dimensions is small, but persistent, after autograft aortic root replacement in adults, and further reoperations should be anticipated. Use of the inclusion cylinder root replacement technique seems to prevent neo-aortic dilatation.  相似文献   

2.
BACKGROUND AND AIM OF THE STUDY: The diameters and distensibility of the native pulmonary root and their effect on pulmonary autograft performance were examined pre- and postoperatively using cardiac ultrasound and magnetic resonance imaging (MRI). METHODS: Eight patients undergoing the Ross procedure were prospectively involved. The diameters of the native aortic, native pulmonary and autograft roots were measured at the level of the annulus, sinus, sinotubular junction and in the main root using MRI through the cardiac cycle. Ultrasound was also used to estimate the degree of regurgitation, both pre- and postoperatively. RESULTS: The pulmonary root implanted into the systemic circulation increased in size but decreased in distensibility significantly at the sinus, sinotubular junction and main root, but not at the annulus. Postoperatively, the pulmonary autograft annulus showed a similar size and distensibility to that of the native aortic annulus. A wide range of aortic annular sizes (22-30 mm) produced clinically competent valves postoperatively. All undersized pulmonary valves showed only trivial regurgitation postoperatively. Although there was no clear correlation between root shape and valve insufficiency, two patients with mild and moderate autograft regurgitation both had divergent pulmonary roots (diameter at sinotubular junction > annulus diameter) preoperatively. CONCLUSION: The pulmonary autograft using the root replacement technique functioned well in all but one case. The shape of the native pulmonary root may be a determinant of early autograft regurgitation, as well as the diameter and the size mismatch between the great arteries.  相似文献   

3.
Percutaneous aortic valvuloplasty using a single dilating balloon has been associated with significant but modest reduction in transvalvular pressure gradient and increase in valve area. The balloon diameter is usually 20 mm or smaller to avoid disruption of aortic root structure and to permit forward blood flow during inflation. To evaluate the safety and efficacy of valvuloplasty using a combination of balloons with larger maximum inflated diameters, we compared results of aortic valvuloplasty in 21 patients using either the single or double balloon technique. Mean maximum inflated balloon diameter was 19.4 mm +/- 1.4 for the single balloon technique, while the mean sum of diameters for the simultaneous double balloon technique was 36.3 mm +/- 3.9. The mean age, aortic annulus diameter, and predilatation aortic valve area were not different among groups. Mean aortic transvalvular gradient reduction and mean aortic valve area increase were greater for the double balloon technique. The procedure was well tolerated with no major complications. No change in the degree of aortic regurgitation was noted. The double balloon technique for aortic valvuloplasty is safe and more effective at improving aortic valve area and transvalvular gradient than the conventional single balloon technique.  相似文献   

4.
目的:建立经导管主动脉瓣置换(transcatheter aortic valve replacement,TAVR)的动物实验方法,确定适合于TAVR的实验动物模型及主动脉根部造影的最佳投照体位。方法:选用健康绵羊15只(体质量40~45 kg),于颈中、下1/3处到胸骨上窝区间,通过超声心动图和血管超声分别测量绵羊主动脉瓣环直径和颈总动脉直径。分离绵羊颈总动脉,于直视下测量其直径。穿刺颈总动脉,送入猪尾巴导管,行左心室造影,确定主动脉根部最佳投照体位并进行影像学分析。行颈总动脉横切口,依次置入20F和24F介入式大动脉支架(主动脉覆膜支架)输送鞘,观察能否顺利通过。分别在置入前后,经胸超声心动图(TTE)测量主动脉瓣有效瓣口面积(effective orifice area,EOA)、返流百分比、心率,经心导管测量主动脉收缩压(aortic systolic pressure,ASP)、主动脉舒张压(diastolic aorticpressure,DAP)、平均主动脉压(mean aortic pressure,MAP)、左心室收缩压(left ventricular systolic pressure,LVSP)、左室舒张末压(left ventricular end diastolic pressure,LVEDP)。结果:用超声心动图测得收缩期主动脉瓣环直径为(24.98±2.41)mm,舒张期主动脉瓣环直径为(19.82±2.14)mm。用血管超声测得颈中、下1/3处颈总动脉直径为(5.61±0.50)mm,颈总动脉胸廓入口处直径为(9.16±0.84)mm。解剖直视下测得的颈中、下1/3处颈总动脉直径为(5.90±0.64)mm。15只绵羊均可经颈总动脉成功置入20F输送鞘,13只绵羊可成功置入24F输送鞘。造影结果显示,右前斜位2.5°±3°、头足位7.1°±6°,可清楚显示绵羊左、右冠脉的开口及主动脉根部的解剖形态。术后存活绵羊(14只)主动脉瓣的EOA、返流百分比、心率、ASP、DAP、MAP、LVSP、LVEDP与术前测量值差异均无统计学意义。结论:经绵羊颈总动脉可建立逆行TAVR实验模型,右前斜位2.5°±3°、头足位7.1°±6°,可获得良好的主动脉根部影像,满足应用介入瓣膜输送系统进行TAVR动物实验研究的需要。  相似文献   

5.
目的 比较不同的二维及三维方法对重度主动脉瓣狭窄患者瓣环径测值的差别,探讨最优测量手段.方法 32例重度主动脉瓣狭窄患者,分别行二维经胸超声心动图(TTE)、二维经食管超声心动图(TEE)及多排螺旋CT(MSCT)三维成像测量主动脉瓣环径.结果 MSCT显示主动脉瓣环为椭圆形结构,其长轴径(26.9±2.9)mm,短轴径(21.3±1.8)mm,长轴径与短轴径差异有统计学意义(P<0.01).TTE及TEE方法仅提供一个瓣环值,分别为(23.2±2.0)mm及(23.4±2.0)mm,均显著小于MSCT所测长轴径和短轴径的平均值(24.1±2.1)mm(P<0.05).结论 主动脉瓣环为椭圆形,瓣环径的测量采用三维MSCT方法更佳.  相似文献   

6.
OBJECTIVES: The present study evaluates complete supra-annular bioprostheses in patients with an aortic annulus of 18 to 23 mm in diameter. BACKGROUND: Aortic valve replacement in patients with small aortic annulus using stented bioprostheses is often associated with unsatisfactory hemodynamic results and high incidence of patient-prosthesis mismatch. METHODS: Between February 2000 and January 2004, 156 patients with aortic valve disease and an aortic annulus of 18 to 23 mm in diameter received the stented bovine Soprano (Sorin Biomedica Cardio, Saluggia, Italy) (n = 18), Perimount (Edwards Lifesciences, Irvine, California) (n = 52), Perimount Magna (Edwards Lifesciences) (n = 42), or the stented porcine Mosaic (Medtronic Inc., Minneapolis, Minnesota) (n = 44) bioprostheses. Intraoperatively, the surgeon measured the aortic annulus diameter by inserting a hegar dilator. Thus, postoperative hemodynamic results could be referred to the patient's aortic annulus diameter instead of referring the results to the labeled valve size. This allows for objective comparisons between different valve types. RESULTS: There was no significant difference in hemodynamic results between the different valve types in patients with an aortic annulus 18 to 20 mm. In patients with an annulus 21 to 23 mm, the Magna was significantly superior to the other investigated devices in mean pressure gradient, effective orifice area, and incidence of patient-prosthesis mismatch. There was no significant difference between the complete supra-annular bioprostheses Mosaic and Soprano and the intra-supra-annular Perimount valve. CONCLUSIONS: In patients with an aortic annulus of 18 to 20 mm in diameter, hemodynamic performance is independent of the implanted stented valve type and the annular position. Root enlargement or stentless valves may be beneficial alternatives. Patients with annulus diameter 21 to 23 mm benefit from the Magna in complete supra-annular position leading to superior hemodynamic results.  相似文献   

7.
Echocardiographic follow-up after Ross procedure in 100 patients   总被引:2,自引:0,他引:2  
The Ross procedure could provide an ideal aortic valve replacement method in children and young adults. We evaluated midterm echocardiographic results to assess pulmonary homograft function as well as pulmonary autograft dimensions and function. In all, 105 patients (26 women and 79 men) underwent the Ross procedure; median age at implant was 29 years. All patients underwent free root replacement. Transvalvular gradients and autograft dimensions were measured at 3 levels (annulus, sinuses of Valsalva, and proximal aorta) at discharge, at 6 months, and annually thereafter. Perioperative mortality was 4.7%. The mean period for echocardiographic follow-up in 100 patients was 32.7 months (range 0.5 to 7 years), during which 4 noncardiac-related deaths occurred. Two patients underwent late reintervention. No moderate or severe regurgitation was recorded. There was 1 case of mild homograft regurgitation and 4 of mild autograft regurgitation at late follow-up. Autograft peak gradients were low and reproducible (5 +/- 2.8 mm Hg at discharge vs 5.5 +/- 3.5 mm Hg at last follow-up, p = NS). Homograft peak gradients increased significantly without severe obstruction (7.8 +/- 5.7 mm Hg at discharge vs 15.8 +/- 9.2 mm Hg at last follow-up). The diameter of the autograft annulus was stable during follow-up, whereas autograft dimensions at sinuses and proximal aorta increased significantly. One group of patients was identified with sinus diameter increases >20% (group A). The 90 remaining patients were classified into group B. The only parameter significantly different between the 2 groups was the sinus diameters measured at discharge (1.74 cm/m2 (group A) vs 1.92 cm/m2 (group B); p = 0.036). In 100 patients and with echocardiographic follow-up for up to 7 years, the Ross procedure showed excellent results. For 10% of patients, we observed a 20% dilation of sinus diameters, but in only 3 patients (3%) was this beyond the upper normal limit.  相似文献   

8.
BACKGROUND AND AIM OF THE STUDY: The root replacement (RR) method for insertion of the pulmonary autograft (PA) has resulted in improved immediate aortic valve competence. However, the unsupported pulmonary artery wall is thinner, more elastic, and thus more prone to dilatation than the normal aortic root. This might predispose to late aortic regurgitation (AR) due to splaying of the aortic commissures, similar to the mechanism of AR in Marfan's syndrome. METHODS: A fully supported root replacement (FSRR) method was designed and implemented in 78 patients, with preservation of the aortic root and proximal ascending aortic remnant fully to surround and support the PA root. Additional aortic annulus reduction was performed in 29 patients, and adjustment of the sinotubular diameter in 27. RESULTS: Seventy-eight patients were analyzed with sequential Doppler echocardiography. The maximal neoaortic sinus diameter remained constant for up to three years after surgery (mean 34.3 +/- 4.0 mm) compared with before surgery (35.2 +/- 4.0 mm). There was one early death, no late deaths or reoperations, and at last follow up AR was nil/trivial in 72% of patients, mild in 27% and moderate in 1%. There was no progression of AR over four years' follow up. By comparison, four patients previously underwent unsupported RR for insertion of the PA; in these patients, mean neoaortic sinus diameter increased significantly from 31 +/- 6 mm to 41 +/- 3 mm at three years after surgery (p = 0.005). CONCLUSIONS: Insertion of the PA using a FSRR method prevents dilatation of the neoaortic sinuses and sinotubular junction without need for prosthetic material, and provides similar results to conventional RR with regard to aortic valve competence. Retaining the advantages of RR in this manner and maintaining aortic root size may prove valuable in the longer term.  相似文献   

9.
BACKGROUND AND AIM OF THE STUDY: The three-dimensional motion of semilunar attachment of the leaflet 'annulus' remains obscure. It has been suggested that the aortic root is distensible and moves during the cardiac cycle. In the present study, the aortic root was evaluated using two dimensions. The aortic root, notably motion of the aortic annulus, was evaluated using multidetector computed tomography (MDCT), and a three-dimensional reconstruction of the aortic annulus was performed. METHODS: Twenty-five patients (17 males, eight females) underwent MDCT. None of the patients had aortic root disease, aortic valve disease, bicuspid valve, myocardial infarction or atrial fibrillation. The aortic annulus was measured in systole and diastole, and divided into three parts: the right coronary cusp (RCC), left coronary cusp (LCC) and non-coronary cusp (NCC). The lengths of the aortic annulus, sinus of Valsalva and sinotubular junction (STJ) were also measured in systole and diastole on longitudinal views. RESULTS: The lengths of each aortic annulus part in systole and diastole were as follows. In systole: RCC 41.8 +/- 8.1 mm; LCC 39.3 +/- 5.9 mm; NCC 43.7 +/- 7.1 mm. In diastole: RCC 42.4 +/- 7.0 mm; LCC 38.6 +/- 7.8 mm; NCC 41.5 +/- 7.8 mm. No statistically significant differences were observed between lengths in systole and diastole. The longitudinal lengths of aortic annulus, sinus of Valsalva and STJ at each period were as follows. In systole: aortic annulus 22.5 +/- 2.2 mm; sinus of Valsalva 34.9 +/- 4.3 mm; STJ 28.1 +/- 3.2 mm. In diastole: aortic annulus 22.1 +/- 2.2 mm; sinus of Valsalva 34.4 +/- 4.7 mm; STJ 27.2 +/- 3.1 mm. The length of the STJ in systole was significantly greater than that in diastole. CONCLUSION: In the normal aortic root, no part of the aortic annulus changed length during the cardiac cycle. According to changes in aortic root dimensions, the commissures move outwards during the systolic phase.  相似文献   

10.
The purpose of the present study was to compare the aortic valve area, aortic valve annulus, and aortic root dimensions measured using magnetic resonance imaging (MRI) with catheterization, transthoracic echocardiography (TTE), and transesophageal echocardiography (TEE). An optimal prosthesis--aortic root match is an essential goal when evaluating patients for transcatheter aortic valve implantation. Comparisons between MRI and the other imaging techniques are rare and need validation. In 24 consecutive, high-risk, symptomatic patients with severe aortic stenosis, aortic valve area was prospectively determined using MRI and direct planimetry using three-dimensional TTE and calculated by catheterization using the Gorlin equation and by Doppler echocardiography using the continuity equation. Aortic valve annulus and the aortic root dimensions were prospectively measured using MRI, 2-dimensional TTE, and invasive aortography. In addition, aortic valve annulus was measured using TEE. No differences in aortic valve area were found among MRI, Doppler echocardiography, and 3-dimensional TTE compared with catheterization (p = NS). Invasive angiography underestimated aortic valve annulus compared with MRI (p <0.001), TEE (p <0.001), and 2-dimensional TTE (p <0.001). Two-dimensional TTE tended to underestimate the aortic valve annulus diameters compared to TEE and MRI. In contrast to 2-dimensional TTE, 3 patients had aortic valve annulus beyond the transcatheter aortic valve implantation range using TEE and MRI. In conclusion, MRI planimetry, Doppler, and 3-dimensional TTE provided an accurate estimate of the aortic valve area compared to catheterization. MRI and TEE provided similar and essential assessment of the aortic valve annulus dimensions, especially at the limits of the transcatheter aortic valve implantation range.  相似文献   

11.
In 38 consecutive patients the pulmonary autograft was usedin aortic root replacement. Investigations were performed withtransthoracic echocardiography, trans-oesophageal echocardiographyand magnetic resonance imaging in 31, 27 and 27 patients respectively.The mean age at operation was 28·7 years (range 19·0–52·0)and the follow-up period was 2·8 years (range 0·8–6·7).The pul-monary autograft diameter was measured at the subannularregion (1), at the annulus at the hinge points of the valveleaflets (2), at the sinus (3), at the sino-tubular junction(4) and at the distal part of the autograft (5). With trans-oesophagealechocardiography the mean systolic measurements at levels 1to 5 were 32, 31, 42, 35 and 34mm, respectively. The correspondingdiastolic measurements were smaller: 25, 28, 42, 35 and 34mmrespectively. There was no significant difference between transthoracicecho-cardiography and transoesophageal echocardiography measurementsof the proximal autograft (levels 1–3). Diameters obtainedwith magnetic resonance imaging were 1 to 3mm larger than thoseobtained with transthoracic echocardiography and transoesophagealechocardiography (P<0·05), except the annulus at systole(P>0·3). Conclusions The mean pulmonary autograft diameters measured using transthoracicechocardiography, transoesophageal echocardiography and magneticresonance imaging were larger than native aortic and pulmonarydiameters of a normal population in the same age group. Diametersof the distal 2 levels could not be imaged reliably with transthoracicechocardiography. Magnetic resonance imaging diameter measurementswere, in general, larger than with echocardiography.  相似文献   

12.
AIM: Patients with Marfan syndrome may develop dissection due to progressive dilatation in the entire aorta, which is not always predictable by mere anatomic assessment of the aortic diameter, especially of the descending aorta. The aim of this study was to identify the predictive value of aortic stiffness on the occurrence of dissection and progressive aortic dilatation. METHODS AND RESULTS: In 78 non-operated patients with Marfan syndrome (mean age 31+/-8 years, mean aortic root diameter 43+/-6 mm, range 31-55 mm) aortic stiffness and diameters were assessed by magnetic resonance imaging (MRI) at multiple levels. After a median follow-up of 71 months (25-75%: 68-72 months) a second MRI was performed and the incidence of aortic dissection and progressive aortic dilatation, defined as mean aortic diameter increase >1 mm/year was determined. During follow-up, 4 (5%) of 78 patients developed an aortic dissection (1 type A, 2 type B, and 1 infra-renal dissection). Twenty (26%) of the 78 patients had progressive aortic root dilatation. There were 5 (6%) patients with progressive descending thoracic aortic dilatation and 6 (7%) with progressive abdominal aortic dilatation. Multivariate logistic regression analysis revealed that local distensibility was an independent predictor of progressive thoracic descending aortic dilatation (OR=4.14, 95% CI, 1.02-16.7). For progressive aortic root and abdominal aortic dilatation local initial diameter appeared to be the major predictor (OR=1.37, 95% CI, 1.16-1.62; OR=1.36, 95% CI, 1.09-1.69, respectively). CONCLUSION: In patients with Marfan syndrome both aortic diameter and aortic distensibility are independent predictors of progressive aortic dilatation. For optimal risk assessment and monitoring of patients with Marfan syndrome, both aortic stiffness and diameter should be assessed at least annually.  相似文献   

13.
Aortic root growth in men and women with the Marfan's syndrome   总被引:4,自引:0,他引:4  
The leading cause of premature death in patients with Marfan's syndrome (MS) is type A aortic dissection or rupture due to progressive aortic root dilation. The aim of this study was to analyze aortic root growth in 113 men and 108 women with MS. All patients were prospectively followed with serial echocardiograms of the native aortic root. At baseline, women had on average a 5-mm smaller aortic root diameter adjusted for age than men. Average aortic root growth was 0.42 mm/year (SE 0.05) in men and 0.38 mm/year (SE 0.04) in women. On the basis of aortic root growth rates, the men and women could be divided into 2 normally distributed subgroups: fast and slow growers. Approximately 1 in 7 men (1.5 mm/year, SE 0.5) and approximately 1 in 9 women (1.8 mm/year, SE 0.3) had fast-growing aortic root diameters. Significantly more type A dissections (25% vs 4%, p <0.001) were observed in fast growers than in slow growers; this was found in men and women. Type A dissections were observed in 4 men and 9 women. By reducing the cut-off value by 5 mm for elective aortic root replacement in women, type A dissections could have been prevented in 3 women. In conclusion, guidelines should take gender differences into account, and therefore, the investigators propose reducing the threshold for elective aortic root replacement in women with MS by 5 mm.  相似文献   

14.
BACKGROUND AND AIM OF THE STUDY: The St. Jude Medical Epic Supra (ES) valve is a new porcine bioprosthesis designed for complete supra-annular implantation. To date, no in-vivo data regarding the hemodynamic and clinical performance of this valve are available. The study aim was to compare the hemodynamic performance of the ES valve with the completely supra-annular Medtronic Mosaic (MM) porcine valve. METHODS: Between July 2000 and April 2006, 83 patients (39 males, 44 females) underwent aortic valve replacement with either the ES (n = 44) or MM (n = 39) bioprosthesis. Hemodynamic performance was evaluated echocardiographically at six months postoperatively. Comparison between the valves was performed by dividing the patient groups according to their intraoperatively measured tissue annulus diameter rather than the labeled valve size. RESULTS: The internal diameter and sewing ring diameter differed in ES and MM valves with the same labeled size. For example, in valves labeled '23' the internal diameter/sewing ring diameters were 21.5 and 29.3 mm in the ES valve versus 20.5 and 30 mm in the MM. The mean pressure gradients (MPG) for patients with ES or MM valves were 15.5 +/- 4.5 or 14.8 +/- 5.1 mmHg for annulus diameter < or =22 mm, 14.6 +/- 6.4 or 13.9 +/- 3.6 for annulus diameter 23-24 mm, and 15.3 +/- 3.8 or 13.4 +/- 4.2 mmHg for annulus diameter > or =25 mm. No significant differences were identified in the hemodynamic data, including MPG, effective orifice area (EOA) and effective orifice area index (EOAI). The incidence of moderate or severe patient-prosthesis mismatch (PPM) was 40% (n = 18) and 5% (n = 1) in patients with ES valves, and 26% (n = 10) or 23% (n = 9) in patients with MM valves (p = 0.01). In patients with an annulus size < or =22 mm, severe PPM occurred in 29% (n =5) of patients with MM valves but in none of those with ES valves. CONCLUSION: The hemodynamic performance of the ES valve was comparable to that of the well-established MM valve. The incidence of severe PPM was lower in patients with ES valves than MM valves, presumably due to the somewhat larger EOA values in patients with a small aortic annulus (<25 mm).  相似文献   

15.
BACKGROUND AND AIM OF THE STUDY: Controversy exists with regard to the indications and technique for valve-preserving aortic root reconstruction. Here, the authors' clinical experience with three techniques is reported. METHODS: Between October 1994 and October 2000, 71 patients (46 men, 25 women; median age 53 years; range: 21-81 years) underwent aortic root reconstruction with preservation of the aortic valve and replacement of ascending aorta. Factors that affected survival and need for subsequent aortic valve replacement were analyzed using univariate analysis. RESULTS: Indications for operation were chronic aneurysm in 65 patients, acute dissection in five, and chronic aneurysm with dissection in one patient. Forty patients were asymptomatic. Presenting symptoms included shortness of breath in 16 patients, chest pain in 14 and transient ischemic attacks in one patient. Twenty patients had Marfan syndrome. The reimplantation technique was performed in 52 patients, remodeling technique in 14, and remodeling with sinus graft root replacement technique in five. Postoperative echocardiography demonstrated absent to mild aortic insufficiency in 63 patients. Operative mortality was 2.8%. Actuarial survival was 84.1% at 5 years; freedom from reoperation was 88.8% and 78.9% at one and three years, respectively. Eleven patients (21.2%) repaired by the implantation technique required aortic valve replacement secondary to aortic valve insufficiency. By univariate analysis, the necessity of aortic cusp repair (p = 0.0009), aortic annulus size >25 mm (p = 0.04), and male gender (p = 0.04) were predictors for subsequent aortic valve replacement. CONCLUSION: Aortic valve-preserving surgery is possible with a low morbidity and mortality. The authors' experience shows a high failure rate in males with a large annulus needing aortic cusp repair and undergoing the reimplantation technique.  相似文献   

16.
BACKGROUND: Definition of normative data of the great arteries from neonatal to adult ages may aid in assessment of the growth of cardiovascular structures, thus guiding the timing and type of intervention in patients with congenital cardiac disease. METHODS: We calculated the cross-sectional areas of the arterial roots at the basal attachment of the valvar leaflets, the sinuses, and standardized distal sites using cineangiograms of 59 normal children and adolescents with mean age of 5.4 plus or minus 4.7 years and a range from 0.1 to 16 years, the children having a mean weight of 21.2 plus or minus 15.7 kilograms, with a range from 2.2 to 68 kilograms, and mean height of 108 plus or minus 35 centimetres, with a range from 43 to 184 centimetres. Values at each site were calculated averaging end-diastolic and end-systolic measurements, and indexed to body surface area. Results are expressed as the mean plus or minus the standard deviation. RESULTS: The diameter of the aortic root at the basal attachment of the leaflets was 249 plus or minus 26, the midpoint of the sinuses 379 plus or minus 59, the sinutubular junction 290 plus or minus 58, the isthmus 158 plus or minus 36, the postisthmic region 152 plus or minus 33, and the descending aorta at the level of diaphragm 130 plus or minus 18 millimetres squared per metre squared. The pulmonary root measured at the basal attachment of the leaflets was 253 plus or minus 28, the midpoint of the sinuses 352 plus or minus 58, the sinutubular junction 293 plus or minus 58, the right pulmonary artery 176 plus or minus 25, the left pulmonary artery 153 plus or minus 20, and sum of right and left pulmonary arteries 330 plus or minus 37 millimetres squared per metre squared. All indexes were consistent over a wide range for body surface areas. CONCLUSIONS: Definition of normative data of the great vessels may aid in the evaluation of congenital or acquired abnormalities, serving as guidelines for intervention during medical or surgical management and follow-up.  相似文献   

17.
Bicuspid aortic valve (BAV) is associated with premature valve dysfunction and abnormalities of the ascending aorta. Limited data exist regarding serial changes of aortic dilation in patients with BAV. We studied paired transthoracic echocardiograms of 68 patients with BAV (mean age 44 years) and with at least 2 examinations >12 months apart (mean follow-up 47 months) to characterize the progression of aortic dilation and the natural history of valve function. We measured aortic root and ascending aortic diameters at baseline and follow-up. We measured aortic gradients and severity of aortic regurgitation (AR). During follow-up, aortic diameters increased at the sinuses of Valsalva by 1.9 mm (95% confidence interval [CI] 1.3 to 2.5), at the sinotubular junction by 1.6 mm (95% CI 0.8 to 2.3), and at the proximal ascending aorta by 2.7 mm (95% CI 1.9 to 3.6). Mean rate of diameter progression was 0.5 mm/year at the sinuses of Valsalva (95% CI 0.3 to 0.7), 0.5 mm/year at the sinotubular junction (95% CI 0.3 to 0.7), and 0.9 mm/year at the proximal ascending aorta (95% CI 0.6 to 1.2). Progression was observed regardless of hemodynamic function at baseline. Mean aortic valve gradient increased significantly from baseline to follow-up (17.6 mm Hg vs 25.7 mm Hg, p <0.001). The degree of AR increased during follow-up in 17 patients (25%). In addition, progression of aortic diameter dilation occurred irrespective of baseline valve function in adult patients with BAV. We also observed considerable progression of aortic gradients and AR over time.  相似文献   

18.
Although the measurement of left atrial diameter (LAD) is a standard part of anyechocardiographic examination, the normal range for adults has never been well established or correlated with body surface area (BSA) and sex. We studied 100 males and 100 females whose ages ranged from 15 to 70 years, with no evidence of mitral value disease or other form of heart disease which might cause left atrial enlargement. All measurements were obtained between the external surface of posterior aortic root (AR) and the internal surface of the left atrial wall and were recorded at ventricular end diastole (ED) as well as end systole (ES). The LAD at ED ranged from 9.5 to 29.5 mm with a mean of 19 mm ± 5.0 S.D.; the diameter at ES ranged from 18.3 mm to 38.7 mm with a mean of 28.5 mm ± 5.1 S.D. The mean LAD at ED was 20.7 mm ± 4.8 S.D. in males compared to the mean diameter of 18.3 ± 4.9 S.D. in females which represents a significant difference (p<0.001). The LAD did not correlate with BSA. The left atrial dimension by ultrasound in these 200 normal patients was compared with the same measurement in 50 catheterized patients with mitral valve disease and proven left atrial enlargement. When absolute values of the left atrial dimension both at end systole and end diastole were determined by ultrasound, there was a clear separation between normal and abnormal (p<0.0001).  相似文献   

19.
Although the measurement of left atrial diameter (LAD) is a standard part of any echocardiographic examination, the normal range for adults has never been well established or correlated with body surface area (BSA) and sex. We studied 100 males and 100 females whose ages ranged from 15 to 70 years, with no evidence of mitral value disease or other form of heart disease which might cause left atrial enlargement. All measurements were obtained between the external surface of posterior aortic root (AR) and the internal surface of the left atrial wall and were recorded at ventricular end diastole (ED) as well as end systole (ES). The LAD at ED ranged from 9.5 to 29.5 mm with a mean of 19 mm +/- 5.0 S.D.; the diameter at ES ranged from 18.3 mm to 38.7 mm with a mean of 28.5 mm +/- 5.1 S.D. The mean LAD at ED was 20.7 mm +/- 4.8 S.D. in makes compared to the mean diameter of 18.3 +/- 4.9 S.D. in females which represents a significant difference (p less than 0.001). The LAD did not correlate with BSA. The left atrial dimension by ultrasound in these 200 normal patients was compared with the same measurement in 50 catheterized patients with mitral valve disease and proven left atrial enlargement. When absolute values of the left atrial dimension both at end systole and end diastole were determined by ultrasound, there was a clear separation between normal and abnormal (p less than 0.001).  相似文献   

20.
BACKGROUND AND AIM OF THE STUDY: In patients with aneurysms or dissections of the ascending aorta and additional aortic valve disease, valve-containing composite grafts are used in clinical routine. The study aim was to present our experience with homografts for aortic valve replacement extended by a vascular prosthesis as an alternative to the classical Bentall procedure. METHODS: Thirty consecutive patients (mean age 46+/-14 years) were included in this study. Indications for valve replacement were aortic stenosis (n = 15), aortic insufficiency (n = 6), combined aortic valve disease (n = 6), endocarditis of the native valve (n = 1), and endocarditis of a previously placed bioprosthesis (n = 2). The mean diameter of the ascending aorta was 5.6+/-0.5 cm; one patient had an acute dissection (diameter 4.4 cm). For valve replacement, cryopreserved homografts (mean size 24+/-2 mm) were used in a mini-root technique, and the ascending aorta was replaced by collagen-coated vascular prostheses (mean diameter 28+/-3 mm). The size of the vascular prosthesis was adjusted to the diameter of the sinutubular junction of the implanted homograft. Follow up included annual clinical examinations, transthoracic echocardiography and ultrafast computed tomography (CT) scans. RESULTS: All patients survived surgery, and no deaths occurred during follow up. None of the patients had postoperative anticoagulation, and no thromboembolic events were noted. Follow up was complete, with an average 48 months (range: 6 to 84 months). Doppler echocardiography revealed trivial to mild aortic regurgitation in nine patients postoperatively, with no deterioration during follow up. No pathologic pressure gradients over the aortic valves were measured at Doppler echocardiography; the mean valvular orifice area was 2.5+/-0.3 cm2. At ultrafast CT, normal homograft anatomy including the sinotubular junction, no calcifications, and no signs of annular dilatation were seen. In the patient who had surgery for acute endocarditis of the native valve, ultrafast CT revealed a small pseudoaneurysm below the left coronary artery, without need for reoperation. CONCLUSION: Short- and mid-term results show that cryopreserved homografts extended by small-sized vascular prostheses can be used safely for Bentall procedures in selected cases where the diameter of the aortic valve annulus is moderately dilated.  相似文献   