首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: The aim of our prospective study was to determine the diagnostic accuracy of planar breast imaging with 99mTc-MIBI in detecting malignant disease. MATERIAL AND METHODS: Ninety-six consecutive patients with 121 clinically- and/or mammographically-detected breast lesions underwent preoperative planar scintimammography. Ten minutes after injection of 700 MBq 99mTc-MIBI, two lateral prone and one anterior supine projections with an acquisition time of 8 minutes each were obtained. Interpretation of scintimammographic results was made blindly and any focal accumulation of MIBI in the breasts was the criterion for an abnormal scintigram. All lesions were operated on and histologically verified. RESULTS: Histologically, 86 malignant and 35 benign lesions were found in 121 breast lesions. A sensitivity of 83.7% and a specificity of 74.2% for malignancy was achieved at planar scintimammography. CONCLUSION: Scintimammography with 99mTc-MIBI is an imaging modality of modest usefulness in the investigation of breast lesions. The method has a low sensitivity in lesions smaller than 10 mm in diameter, which decreases the clinical use of the method.  相似文献   

2.
PURPOSE: The aim of our prospective study was to evaluate the role of planar scintimammography with 99mTc-MIBI in detecting axillary lymph node metastases in women with primary breast carcinoma. MATERIAL AND METHODS: Fifty-eight patients underwent scintimammography rior to axillary lymph node dissection. Ten minutes after injection of 700 MBq 99mTc-MIBI, two prone lateral projections were obtained, followed by a supine anterior projection. Sixty-one axillae (3 bilateral) were operated upon and the status of the lymph nodes verified with histopathology. The scintigraphic result was compared to the histopathologic findings. RESULTS: A sensitivity of 67% and a specificity of 80% of planar scintimammography in detecting axillary lymph node metastases were achieved. CONCLUSION: Scintimammography with 99mTc-MIBI is not recommended as a routine method for the detection of axillary lymph node metastases in patients with breast carcinoma.  相似文献   

3.
OBJECTIVE: This study compares 2 imaging protocols, planar pinhole technique (PPHT) and SPECT, for evaluating ocular masses with 99mTc-MIBI. METHODS: Sixteen patients with ocular lesions were studied. Planar images were acquired 10 min after the injection of 740 MBq 99mTc-MIBI with an LFOV camera fitted with a pinhole collimator (5.0 mm). A SPECT study was performed immediately after the planar study, using a 360 degrees orbit, 64 steps, 20 s/stop, a 128 x 128 matrix, and a low-energy high-resolution (LEHR) collimator. Twelve lesions (9.5-18.0 mm) proved to be malignant: 8 primary tumors (ocular melanoma); 3 local relapses of different tumors of the conjunctiva; and 1 ocular metastasis from breast cancer. The remaining 4 lesions (10.0-16.0 mm) were benign: 1 inflammatory lesion; 1 benign intraocular calcification; and 2 naevi. RESULTS: SPECT images showed 11 of 12 malignant lesions (91.6%), whereas the planar technique demonstrated only 4 of the 12 lesions (33.3%). One false-positive result, the inflammatory lesion, was visualized by both techniques. The remaining benign lesions were not detected with either method. CONCLUSION: Technetium-99m-MIBI SPECT is a sensitive technique for detecting malignant ocular tumors. SPECT imaging is a better alternative to planar imaging for ocular tumors.  相似文献   

4.
AIM: We evaluated the usefulness of (99m)Tc-tetrofosmin axillary pinhole (P)-SPECT in breast cancer (BC) non palpable axillary lymph node metastasis detection compared with conventional planar and SPECT scintimammography. METHODS: We studied prospectively 188 consecutive patients with suspected primary BC, negative at axillary clinical examination. Ten minutes after 740 MBq (99m)Tc-tetrofosmin injection, planar and SPECT scintimammography were acquired, followed by axillary P-SPECT imaging. RESULTS: At histology, 12 patients had benign mammary lesions and 176 had BC. Axillary lymph node dissection (ALND) was performed in all BC patients, bilaterally in 3 cases: 74/179 axillae had metastases. P-SPECT showed a significantly higher overall sensitivity than SPECT and planar (93.2% vs 85.1% and 36.5%, respectively; p<0.05 and p<0.0005, respectively) and was false negative in 5 patients with 1 metastatic node each, micrometastatic in 4/5 cases; SPECT and planar were also false negative in these 5 cases and in 6 and in 42 further cases, respectively. P-SPECT added important prognostic information by distinguishing single from multiple and pound 3 from >3 nodes; only P-SPECT defined the exact number of nodes in 15/25 patients with 2-4 nodes. P-SPECT showed the highest accuracy and NPV: 92.7% and 95%, respectively (SPECT 90.5% and 90%, respectively; planar 73.2% and 68.9%, respectively). CONCLUSION: (99m)Tc-tetrofosmin axillary P-SPECT appears highly accurate in BC non palpable axillary lymph node metastasis detection and significantly more sensitive than both planar and SPECT, its few false negative results predominantly concerning micrometastases; moreover, only P-SPECT gave additional important prognostic information. Given its very high NPV, P-SPECT could also be used to better select patients who might avoid ALND.  相似文献   

5.
目的:比较99mTcMIBI与99mTcOctreotide生长抑素受体显像对乳腺癌诊断的临床价值。材料和方法:对36例怀疑为乳腺癌的患者术前行99mTcMIBI显像,48小时后行99mTcOctreotide生长抑素受体显像,以术后病理检查结果作为金标准。结果:36例中,25例为乳腺癌,其中11例发生腋窝淋巴结转移;11例患者为乳腺良性病变。两种显像方法对乳腺癌诊断的灵敏度、特异性、准确性分别为92.0%、63.6%、83.3%和92.0%、27.3%、72.2%。结论:99mTcMIBI显像与99mTcOctreotide生长抑素受体显像对乳腺癌均有较好的诊断价值,但99mTcOctreotide生长抑素受体显像诊断特异性较低。由于本研究的病例数有限,有待于进一步的工作深入探讨。  相似文献   

6.
OBJECTIVE: We studied the usefulness of 99mTc-methoxyisobutylisonitrile (MIBI) scintigraphy for differentiation between active and inactive pulmonary tuberculosis. METHODS: Thirty-six patients (aged 27-82 years, 16 males and 20 females) were included in our study. Each patient was injected with 740 MBq (20 mCi) 99mTc-MIBI and both planar and single photon emission computed tomography (SPECT) imaging were performed 15 and 60 min after injection. Twenty-four patients had active pulmonary tuberculosis (proven by sputum culture), and the remainder 12 had negative sputum culture. Semiquantitative as well as visual assessments were done on all sets of images. RESULTS: All of the 12 patients in the control group had negative scintigraphy on both planar and SPECT images. Twenty patients with active pulmonary tuberculosis had positive 99mTc-MIBI scintigraphy on planar images (sensitivity of 87.5%). SPECT images were positive in 23 patients with active pulmonary tuberculosis (sensitivity of 95.8%). Both semiquantitative and visual assessment of planar and SPECT images showed statistically significant differences between active and inactive pulmonary tuberculosis patients (P<0.001). Comparison of 15 and 60 min image sets did not show any statistically significant difference (P=0.956 and 0.457 for planar and SPECT images, respectively). CONCLUSION: 99mTc-MIBI has significant uptake in the active tuberculosis lesions and can be used to differentiate between active and inactive tuberculosis. The SPECT method is especially useful because of its higher sensitivity.  相似文献   

7.
The purpose of the present study was to compare scintimammography using technetium-99m hexakis 2-methoxyisobutylisonitrile (MIBI) with that using 99mTc-hydroxymethylene diphosphonate (HMDP) in the detection of breast cancer and its axillary lesions. The study population comprised 50 consecutive females with breast cancer who were scheduled for surgery. All patients underwent scintimammography with 99mTc-MIBI and 99mTc-HMDP. The images were acquired 5 min (early) and 2 h (delayed) after injection of each radiopharmaceutical. Regions of interest were placed over the breast tumour (T), the axillary lesion (A) and the normal ipsilateral breast tissue (N). The two count ratios were calculated, i.e. the tumour to normal breast tissue ratio (T/N) and the axillary lymph node to normal breast tissue ratio (A/N). For the breast tumours, using 99mTc-MIBI the positive rate was 86% (43/50) for the early and 72% (36/50) for the delayed images. The corresponding values using 99mTc-HMDP were 72% (36/50) and 40% (20/50), respectively. Histopathological examination revealed metastatic lymph node involvement in 22 patients. For the axillary lesions, using 99mTc-MIBI the positive rate was 72.7% (16/22) for the early and 54.5% (12/22) for the delayed images. Using 99mTc-HMDP, the positive rate was only 18.2% (4/22) for the early and 4.5% (1/22) for the delayed images. Using 99mTc-MIBI, the mean T/N (+/- SD) ratios on early and delayed images were 2.69 +/- 1.64 and 2.03 +/- 1.16, respectively, and the mean A/N (+/- SD) ratios on early and delayed images were 2.20 +/- 1.23 and 1.80 +/- 1.20, respectively. The corresponding values using 99mTc-HMDP were 1.77 +/- 0.91, 1.42 +/- 0.72, 1.27 +/- 0.63 and 1.08 +/- 0.25, respectively. The T/N and A/N ratios on the early and delayed 99mTc-MIBI images were both significantly higher than those obtained using 99mTc-HMDP. 99mTc-MIBI scintimammography is more sensitive than 99mTc-HMDP scintimammography for the detection of breast cancer and its axillary lymph node metastases.  相似文献   

8.
The aim of this study was to establish whether tumour uptake of 99mTc-MIBI can predict response to chemotherapy in patients with breast carcinoma. Forty women suffering from breast carcinoma confirmed by tumour biopsy were studied prospectively. Fifteen patients subsequently underwent surgery and 25 were candidates for neoadjuvant chemotherapy. Breast scintigraphy was performed and planar and tomographic views (single photon emission computed tomography (SPECT)) were obtained after injection of 740 MBq of 99mTc-MIBI. The tumoural uptake was quantified by computer analysis. P-glycoprotein was evaluated by immunohistochemistry only in operable patients. The response to chemotherapy was evaluated at 3 months upon completion of treatment. The results of this study showed no relationship between 99mTc-MIBI uptake and the histological type or tumour size. There was an inverse correlation with the degree of tumour differentiation (P<0.05). 99mTc-MIBI uptake in negative P-glycoprotein lesions (2.36+/-1.72) was higher than in positive P-glycoprotein lesions (1.53+/-1.29), although the difference was not statistically significant. Lesions which responded to chemotherapy (16) showed higher 99mTc-MIBI uptake (7.70+/-5.20) than non-responding lesions (nine) (2.21+/-1.0) (P<0.001). In conclusion, there is a correlation between 99mTc-MIBI uptake in breast cancer and response to chemotherapy. Furthermore, 99mTc-MIBI uptake may be influenced by other factors such as the degree of tumour differentiation or tumour P-glycoprotein levels.  相似文献   

9.
目的:探讨99mTc-MIBI心肌显像能否成为急性心肌梗塞的快速诊断手段。资料和方法:选择临床确诊的心肌梗塞患者35例,于注射99mTc-MIBI后10min与60min以相同条件分别进行SPECT显像,并以相同条件分析处理图像,记录心肝肺的放射性计数率,比较两次显像结果的差异。结果;10min像阳性率31.2%,60min像为308%,符合率95.2%。有22个节段(4.8%)两次显像缺损程度有差异,以下后壁居多(13/22.59.1%)。图像质量以60min像为佳,心脏计数率随时间延长而降低,而心肝比、心肺比升高。结论:10min显像与60min显像在本组病例中具有很好的诊断一致性,至少可为急性心梗提前50min提供诊断,可望成为急性心梗的一种快速诊断手段。  相似文献   

10.
We include those patients who present with an isolated metastasis of axillary adenopathy in the occult primary breast cancer group. Presumably, the primary tumor is a primitive breast carcinoma, unsuspected until this moment and not clinically demonstrable by mammography or ultrasonography. When no method succeeds in confirming the primary breast lesion, the patients are usually treated assuming the existing of breast cancer. Several diagnostic methods have been used to find the primary breast lesion. Magnetic Resonance imaging (MRI), Positron Emission (PET) and Doppler sonography have been used in this way and several papers present the results reached with them. Our group incorporates detection and radioguided surgery with 99mTechnetium (99mTc) methoxyisobutil isonitrile into the study of these patients. We perform a planar scintimammography and SPECT (Single Photon Emission Computed Tomography) with 99mTc-MIBI. If the radioisotopic method shows a functional image compatible with a carcinoma, a gamma detecting probe is then used to locate the lesion and guide its surgical removal. In this paper, we present the application of the technique in 5 cases and describe the technique and its possibilities. Its advantages are explained in comparison with other methods. The dosimetric values found in the performance of the technique are reported. We consider that detection and radioguided surgery with 99mTc-MIBI in the diagnosis and treatment of occult breast cancer adds an effective tool and means progress in the approach to this disease.  相似文献   

11.
PURPOSE: The authors evaluated the utility of hepatobiliary scintigraphy for tissue characterization of extrahepatic metastases from hepatocellular carcinoma (HCC) using Tc-99m N-pyrydoxyl-5-methyltriptophane (Tc-99m PMT). METHODS: We examined 13 patients with HCC (29 extrahepatic metastases and 3 benign bone lesions) and 5 patients with other cancers (15 extrahepatic metastases). Thirty minutes to 6 hours after intravenous administration of Tc-99m PMT, planar (all 47 lesions) and SPECT (42 lesions) images were obtained. Accumulation of Tc-99m PMT in the lesion was evaluated visually by comparing bone scintigraphy, computed tomography, magnetic resonance imaging, or all of these. RESULTS: Findings were positive in 12 of 13 patients with HCC and extrahepatic metastases (16 of 29 on planar imaging and 21 of 26 on SPECT). Findings in all three benign bone lesions and 15 metastatic lesions from non-HCC primary lesions were negative (0 of 18 on planar imaging, 0 of 16 on SPECT). There were no false-positive findings in these lesions. Lesion-by-lesion sensitivity, specificity, accuracy, and positive and negative predictive values were 55%, 100%, 72%, 100%, and 58% by planar imaging and 81%, 100%, 88%, 100%, and 76% by SPECT, respectively. CONCLUSIONS: Because of the high specificity and reasonable sensitivity, Tc-99m PMT appears to be useful for the differential diagnosis of extrahepatic metastases from HCC. SPECT improves the detectability of small or faint accumulation in metastases from HCC.  相似文献   

12.
The aim of this study was to evaluate the usefulness of (99m)Tc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq (99m)Tc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions < or =10 mm ( P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those < or =10 mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% ( P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of < or =3 nodes ( P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P<0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. (99m)Tc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of (99m)Tc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with < or =3 non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.  相似文献   

13.
OBJECTIVE: Pulmonary Kaposi's sarcoma (KS) occurs in more than 10% of patients with acquired immunodeficiency syndrome (AIDS) and has a high mortality rate. Prompt detection, diagnosis, and treatment reduce patient morbidity and mortality. The objective of this study was to determine the efficacy of 99mTc-hexakis-2-methoxy isobutyl isonitrile (99mTc-MIBI) imaging in detecting pulmonary AIDS-related KS. METHODS: 99mTc-MIBI imaging was performed on 72 human immunodeficiency virus-seropositive patients with bronchoscopic diagnosis of pulmonary KS (36 patients), pneumonia (22), normal tracheo-bronchial tree (11), lymphoma (2), and bronchogenic carcinoma (1). Lung uptake and lymph node detection in KS were compared on planar and single photon emission computed tomography (SPECT) scans. RESULTS: The lung/myocardium ratios on the 1-h planar images were significantly higher in KS and normal lungs than opportunistic infection. Using the lung/myocardium ratio of 1 as cutoff, the sensitivity, specificity, and accuracy of the 1-h planar images for detecting pulmonary KS were 75, 57.58, and 66.67%, respectively. Abnormal lymph node uptake, pleural/pericardial effusions, and ascites were detected more readily on SPECT. CONCLUSION: Planar 99mTc-MIBI imaging has moderate sensitivity, specificity, and accuracy for detecting pulmonary KS. SPECT is more effective in detecting abnormal lymph nodes, pleural/pericardial effusions, and ascites. 99mTc-MIBI SPECT followed by planar imaging at 40-60 min can be useful in assessing pulmonary KS.  相似文献   

14.
99mTc-tetrofosmin, Thallium-201-chloride (201Tl) and 99mTc-MIBI imagings were performed in a patient with malignant thymoma. Tracer uptake in the primary tumor was demonstrated. The tumor-to-background ratios of planar and SPECT imagings were 1.60 and 1.98 for 99mTc-tetrofosmin, 1.12 and 2.09 for 201Tl, and 1.19 and 1.80 for 99mTc-MIBI, respectively. In another patient 99mTc-tetrofosmin and 201Tl imagings were performed. Not only the primary tumor but also the direct invasions and metastatic lesions (bone metastases) were clearly detected. The tumor-to-background ratios of planar and SPECT imagings were 2.31 and 2.78 for 99mTc-tetrofosmin and 2.45 and 3.58 for 201Tl, respectively. In 99mTc-tetrofosmin scintigraphy we acquired delayed images, and the tumor-to-background ratios of planar and SPECT delayed images were 1.20 and 1.86, the retention ratios were -1.11 and -0.92 and the retention indices were -48.1 and -33.1, respectively. Our preliminary results suggest that 99mTc-tetrofosmin is useful in detecting not only the primary tumor but also metastatic lesions from malignant thymoma.  相似文献   

15.
Our objective was to evaluate the role of 99mTc-furifosmin scintigraphy--planar and SPECT--in discriminating benign from malignant breast disease. METHODS: The trial was prospective, open, and diagnostic. We recruited 30 consecutive patients with 14 palpable and 16 nonpalpable breast lesions. After receiving informed consent, we injected 555-640 MBq 99mTc-furifosmin intravenously in the arm contralateral to the breast lesion. Planar imaging and SPECT were performed. All patients underwent excision of the tumor within 2 wk. Using histology as the gold standard, we calculated sensitivity, specificity, and positive and negative predictive values for 99mTc-furifosmin in planar and SPECT technique. RESULTS: For 18 malignant and 12 benign breast lesions, a sensitivity of 50% for planar imaging and 72% for SPECT was seen. Specificity and positive and negative predictive values were 83%, 82%, and 53%, respectively, for planar imaging and 50%, 68%, and 55%, respectively, for SPECT. For the 14 palpable tumors (10 malignant, 4 benign), which averaged 17+/-10 mm in size (size range, 4-45 mm), a sensitivity of 60% for planar imaging and 80% for SPECT was achieved. Sixteen lesions were not palpable (median size, 9+/-3 mm [size range, 4-13 mm]). In this subgroup, 99mTc-furifosmin scintigraphy yielded a sensitivity of 37% for planar and 62% for SPECT technique (P>0.05). CONCLUSION: 99mTc-furifosmin scintigraphy is not a potent competitor to established scintigraphic procedures. In comparing this tracer with 99mTc-sestamibi and 99mTc-tetrofosmin, we cannot recommend 99mTc-furifosmin for the diagnosis of breast cancer.  相似文献   

16.
OBJECTIVE: The aim of this study was to investigate the changes in early and late washout rates of 99mTc-methoxyisobutylisonitrile (MIBI) in hypertrophic cardiomyopathy (HCM), and to analyze the relationships between early and late washout rates and the hypertrophic thickness of left ventricular (LV) wall. METHODS: The patients who were clinically diagnosed as positive for HCM underwent 99mTc-MIBI static planar and gated single-photon emission computed tomography (SPECT) imaging. Early (90 min after the intravenous injection) and late (4 h after the intravenous injection) washout rates of 99mTc-MIBI between HCM group and normal control group were compared. Linear correlation analysis was made between early and late washout rates and the hypertrophic thickness of LV wall measured by gated SPECT. RESULTS: The early and late washout rates of 99mTc-MIBI in normal control group were (18.90+/-3.70) and (31.27+/-4.04)%, respectively; and the washout rates in HCM group were (27.77+/-2.60) and (42.66+/-3.30)%, respectively. Significant statistical differences were observed in the early and late washout rates of 99mTc-MIBI between HCM group and normal control group (t=-7.320 and t=-8.069, both P<0.01). Correlations between early and late washout rates and the maximal hypertrophic thickness of LV wall obtained by gated SPECT were excellent (r=0.611, P<0.05; r=0.873, P<0.01, respectively). CONCLUSION: The early and late washout rates of 99mTc-MIBI in HCM group were significantly higher than those in normal control group, and both the early and late washout rates correlated well with the hypertrophic thickness of LV wall.  相似文献   

17.
Dedicated mammotomography with pinhole incomplete circular orbit (PICO) SPECT imaging of an uncompressed pendant breast was evaluated with small, very-high-stopping-power pinhole apertures. Comparisons were made with planar pinhole scintimammography. Enhanced 3-dimensional imaging performance with very-high-stopping-power apertures is thought to ultimately yield improved sensitivities for lesion detection and identification in breast disease. METHODS: Pinhole collimators made of high-density and high atomic number (184)W or depleted (238)U, with aperture diameters from 1 to 4 mm, were used to image 0.6- and 1.0-cm-diameter spherical lesions in a pendulous, uncompressed breast phantom in planar and PICO-SPECT modes. The breast was centered on the horizontal axis of rotation of an incomplete circular orbit. Lesion, breast and body, and myocardial activities (L:B:M) were included in the phantoms to simulate clinical imaging conditions with (99m)Tc (140 keV). Lesion contrasts and signal-to-noise ratios (SNRs) for all apertures were determined for near clinical acquisition times for L:B:M ratios of 12:1:20 and 7:1:25. A set of minidisks inserted in the breast phantom was scanned to determine sampling limitations at depth from the nipple. In an initial study, a patient with biopsy-confirmed breast carcinoma was injected with 960 MBq (99m)Tc-tetrofosmin and scanned 2 h later with planar pinhole and PICO-SPECT techniques. RESULTS: Overall, for PICO-SPECT imaging there were small differences in measured counting rate sensitivity (4.9%) and lesion contrast (8.8%) with larger SNR differences (20.8%) between tungsten and depleted uranium pinhole materials at this energy and these lesion sizes. Backgrounds from simulated myocardial uptake had minor contributions in all reconstructed image volumes because of the rapid sensitivity fall-off for pinhole apertures. An optimal aperture diameter between 2 and 3 mm was determined from peak SNR, indicating that these aperture sizes may have the best performance for lesions as small as 0.6 cm in diameter with activity concentration ratios of (99m)Tc similar to those currently seen in patients. Both lesions were visualized with PICO-SPECT better than with planar pinhole imaging, with respective contrast improvements >20 times the values obtained from planar imaging for the same pinholes. In the patient study, higher contrast (>6) visualization of the active tumor periphery was obtained with PICO-SPECT than with planar imaging. CONCLUSION: These results indicate that the enhanced spatial resolution of smaller apertures outweighs the loss in sensitivity in small lesion identification with PICO-SPECT. Although the imaging differences between investigated aperture types are small and some limitations to this imaging approach exist, dedicated PICO-SPECT of the breast appears to be an improved technique compared with conventional planar pinhole scintimammography. This technique provides enhanced contrast and SNR for imaging small lesions with the high-resolution pinhole apertures along with 3-dimensional localization of the lesions.  相似文献   

18.
Prone SPET scintimammography   总被引:2,自引:0,他引:2  
Prone single photon emission tomography (SPET) was performed in 24 patients with suspected primary or recurrent breast cancer to determine if this technique offers more accurate imaging than that obtained from planar scintimammography. All patients were imaged on a specially designed couch with two cushion inserts. The first insert was lined with lead and was used to perform prone lateral planar scintimammography 5 min after the injection of 740 MBq 99Tcm-MIBI. The second insert did not contain lead and was used to perform a prone SPET acquisition for 30 min immediately after planar imaging. The results of both studies were read independently and there was agreement between the two techniques in 23 cases (96%). All cases of cancer proven on histology were found on planar imaging, but a 4-mm ductal cancer was missed on prone SPET. This was thought to be due to activity from this medial cancer being obscured by the star artefact produced by back-projection reconstruction from activity in the heart. There were two false-positive studies with both techniques. However, prone SPET enabled better localization and characterization of breast cancers than planar imaging. Prone SPET imaging of the breast produces results similar to prone lateral imaging and may be used instead of planar imaging if a reduced total acquisition time is desirable. Care must be taken when reading scans in the presence of small tumours near the heart when back-projection reconstruction techniques are used.  相似文献   

19.
A phase I clinical study on 99mTc-hexakis 2-methoxy isobutylisonitrile (99mTc-MIBI) was carried out in 6 normal volunteers. There was no significant change in vital signs and laboratory parameters attributing to the reagent other than complaint of slight and transient metallic taste immediately after the injection in 4 volunteers. The highest dosimetry was calculated as 1.1 mGy/37 MBq at lower large intestine, which was within the acceptable range. 99mTc-MIBI was rapidly cleared from the blood and accumulated in the heart immediately after the injection with 1.4% dose and 1.8% dose at 5 min at rest and at stress, respectively. The retention of radioactivity in the heart well continued for at least several hours. The heart-to-lung ratio was over 2.00 at 5 min and heart-to-liver ratio was over 1.00 at 60 min. Myocardial planar and SPECT images were obtained with high quality. In conclusion, 99mTc-MIBI is a useful myocardial perfusion imaging agent.  相似文献   

20.
To determine whether technetium-99m hexakis-2-methoxy isobutyl isonitrile (99mTc-MIBI) myocardial scintigraphy is a superior method in the detection of coronary artery disease, exercise and rest 99mTc-MIBI planar and SPECT scintigraphy were performed on 27 patients with coronary artery disease. When 99mTc-MIBI (555 MBq (15 mCi)) was injected, first-pass radionuclide angiography (FPRNA) was simultaneously performed by a new mobile multicrystal gamma camera (SIM-400), and LV function (LVEF) was evaluated quantitatively. Visual semiquantitative detection of coronary lesions using 99mTc-MIBI images showed superior accuracy to that obtained using 201TlCl images. 99mTc-MIBI SPECT images were particularly useful in diagnosing LCX and RCA lesions. Moreover, the simultaneous assessment of perfusion and left ventricular function by 99mTc-MIBI FPRNA proved to be useful in the diagnosis of multi-vessel disease. In summary, 99mTc-MIBI SPECT scintigraphy with simultaneous assessment of left ventricular function showed better diagnostic accuracy than 201TlCl myocardial scintigraphy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号