首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The clinical and radiographic results of primary cemented total hip arthroplasty performed by a single surgeon, with particular emphasis on the performance of acetabular components implanted with so-called second-generation cement techniques, were studied. Seventy hips with 48 metal-backed and 22 polyethylene acetabular components were followed for a mean of 9 years (range, 5–11.5 years). The clinical results were evaluated using a recognized hip score. The fixation status of the cemented acetabular component was evaluated using two methods of measuring radiolucent lines at 5 years and at the last evaluation. Acetabular component loosening was defined as a circumferential radiolucent line, component migration, or revision for loosening. This study was unable to confirm the findings of others that demonstrated higher failure rates with cemented metal-backed components when compared with all-polyethylene components. The survival of cemented acetabular components with 28-mm head femoral prostheses was worse than the survival of cemented acetabular components with 22-mm femoral heads in other published reports, despite advances in cement techniques. Because of the high rate of loosening of cemented 28-mm-inner-diameter acetabular components at 5 and 10 years, the authors no longer use these cemented components for acetabular reconstruction.  相似文献   

2.
BACKGROUND: Loosening of the acetabular component is the major long-term problem associated with total hip arthroplasty with cement. The purpose of the present study was to evaluate the minimum thirteen-year results associated with cementless acetabular components that had been inserted by a single surgeon and to compare them with the results associated with cemented acetabular components that had been inserted by the same surgeon. METHODS: One hundred and twenty consecutive, nonselected primary total hip replacements were performed in 108 patients with use of a Harris-Galante-I cementless acetabular component and a cemented femoral component with a 28-mm head. The patients were evaluated clinically with use of a standard terminology questionnaire, and they were evaluated radiographically for loosening, component migration, wear, and osteolysis. The rates of revision for aseptic loosening and radiographic evidence of loosening for this cohort were compared with the rates for four previously reviewed consecutive series of hips in which the acetabular component had been inserted with cement. All patients were managed by the same surgeon, were followed for thirteen to fifteen years, and were evaluated with use of the same two criteria (revision and loosening) as the end points for Kaplan-Meier analysis. RESULTS: Sixty-six patients (seventy-two hips) were living and forty-two patients (forty-eight hips) had died after thirteen to fifteen years of follow-up. No acetabular component had been revised because of aseptic loosening, and no acetabular component had migrated. With revision of the acetabular component for any reason as the end point, the survival rate was 81% +/- 8% at fifteen years. With revision of the acetabular component for clinical failure (osteolysis, wear, loosening, or dislocation) as the end point, the survival rate was 94% +/- 8% at fifteen years. Among the seventy hips with at least thirteen years of radiographic follow-up, five had pelvic osteolysis and three had had revision of a well-fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm/yr (0.12 mm/yr when one outlier was excluded). CONCLUSIONS: In terms of fixation, Harris-Galante-I cementless acetabular components performed better than did cemented 22-mm-inner-diameter Charnley acetabular components as well as 28-mm-inner-diameter all-polyethylene and metal-backed acetabular components that had been inserted by the same surgeon. However, the rate of wear was greater in association with the Harris-Galante-I cementless components than it was in association with the Charnley cemented all-polyethylene components.  相似文献   

3.
We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%). After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component.  相似文献   

4.
In 1982, Harris and White reported the data after a minimum five-year follow-up of fifty-three total hip replacements in forty-seven patients in whom a cemented metal-backed acetabular component had been used. There actually had been fifty-four total hip replacements in fifty-three hips, as in one hip a revision was done for a traumatic disruption of the initial acetabular component that occurred two months after the first insertion. Six of the fifty-four operations did not qualify for inclusion in this ten-year follow-up study, including four operations in three patients who had died before that time. The remaining forty-eight hips have been followed for ten to 13.5 years (mean, 11.3 years). With one exception, the ages of the patients at the time of the index operation ranged from seventeen to fifty years (mean, forty-one years). Six (12.5 per cent) of the forty-eight hips required revision because of symptomatic aseptic loosening of the acetabular component. In addition, two acetabular components, although they were not loose, were revised concomitantly with revision of the femoral component because of the presence of radiolucent lines at the cement-bone interface of the acetabular implant. One other acetabular component that was not loose was revised because of unexplained pain, one was removed because of sepsis, and for one only the polyethylene liner was exchanged because of damage to the polyethylene when the weld holding the femoral head to the femoral neck failed. Nine additional hips (19 per cent), although they were not revised, showed radiographic evidence of migration, and one (2 per cent) showed radiographic evidence of impending failure.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a cemented metal-backed component. A total of 50 patients (55 hips) were available for clinical and radiological evaluation at a mean follow-up of 5.8 years (3 to 9.5). No hip required further revision of the acetabular component because of aseptic loosening. All the hips except one had complete incorporation of the allograft demonstrated on the radiographs. A complete radiolucent line of > 1 mm was noted in two hips post-operatively. A good to excellent result occurred in 50 hips (91%). With radiological evidence of aseptic loosening of the acetabular component as the end-point, the survivorship at a mean of 5.8 years after surgery was 96.4%. The use of impacted allograft chips in combination with a cemented metal-backed acetabular component and screw fixation can achieve good medium-term results in patients with acetabular bone deficiency.  相似文献   

6.
BACKGROUND: Acetabular bone deficiency can present a challenge during total hip arthroplasty, especially in young patients. The purpose of the present study was to evaluate the long-term clinical and radiographic outcomes of primary and revision acetabular reconstruction with use of an impaction bone-grafting technique and a cemented polyethylene cup in young patients who had preexisting acetabular bone deficiency. METHODS: Forty-two consecutive acetabular reconstructions were performed in thirty-seven patients who were younger than fifty years old (average, 37.2 years old). The impaction bone-grafting technique was used for twenty-three primary and nineteen revision acetabular reconstructions. Twenty-eight patients (thirty-one hips) were available for review after a minimum duration of follow-up of fifteen years. Clinical and radiographic results were assessed, and survivorship analysis was performed with the Kaplan-Meier method. RESULTS: Eight hips were revised at a mean of twelve years (range, three to twenty-one years) after a primary reconstruction (four hips) or revision reconstruction (four hips). The revision was performed because of aseptic loosening of the acetabular component in four hips and because of culture-proven septic loosening in two. Two additional cups (both in hips that had had a revision reconstruction) were revised, during revision of the femoral stem, because of wear (one hip) or because of persistent intraoperative instability (one hip). Twenty-eight hips (in twenty-five patients) had retention of the acetabular component for a minimum of fifteen years. The mean Harris hip score for that group was 89 points. Twenty-six of these twenty-eight hips had no or slight pain. Kaplan-Meier analysis revealed a twenty-year survival rate of 80% (95% confidence interval, 67% to 94%) with acetabular revision for any reason as the end point and of 91% (95% confidence interval, 80% to 100%) with acetabular revision because of aseptic loosening as the end point. CONCLUSIONS: Acetabular reconstruction with use of impaction bone-grafting and a cemented polyethylene cup is a reliable and durable technique that is associated with good long-term results in young patients with acetabular bone-stock defects.  相似文献   

7.
One hundred twenty-three consecutive primary total hip arthroplasties in 107 patients were performed with the insertion of a cemented, all polyethylene, flanged acetabular component. At a minimum of 20 years, 66 patients had died (75 hips) and 8 patients (8 hips) were lost to follow-up evaluation, leaving 40 hips in 33 patients. At a mean of 21.1 years, 2 cups had been revised for aseptic loosening, one well-fixed cup was revised at the time of femoral component revision, and 4 additional cups had definite evidence of radiographic loosening. Survivorship analysis revealed a 77.3% survivorship for the component at 21 years, with revision or definite loosening as an endpoint (95% confidence interval, 67.8%-86.8%).  相似文献   

8.
To determine the clinical efficacy of an alumina ceramic head, 119 cemented total hip arthroplasties in 97 patients using an alumina head coupled with ethylene oxide gas sterilized polyethylene were reviewed. Eighty-two patients (101 hips) with greater than 10 years followup were evaluated clinically and radiographically (range, 10-17.6 years), and 97 patients (119 hips) were evaluated for survivorship analysis (range, 0.6-17.6 years). The average functional hip scores according to Merle d'Aubigné and Postel improved from 8.6 preoperatively to 15.0 at the final followup, and 57 patients (64 hips) had no pain. The average polyethylene wear rate was 0.15 mm/year (range, 0.04-0.34 mm/year). Patients with polyethylene wear greater than 3 mm showed significantly higher rates of acetabular loosening. Fifteen-year survival rates (with 95% confidence intervals) with radiographic evidence of aseptic loosening as the end point were 46.8% +/- 13.4% in acetabular components and 91.9% +/- 6.6% in femoral components. Fifteen-year survival rates of hip arthroplasties with revision because of aseptic loosening as the end point were 75.3% +/- 10.2% and 97.9% +/- 3.0%, respectively. Results of the current study suggest that using an alumina head instead of a metal head may not be beneficial when coupled with ethylene oxide gas sterilized polyethylene.  相似文献   

9.
The optimal fixation of the acetabular component in primary total hip arthroplasty remains controversial. Long-term follow-up studies show that significant loosening rates occur with cemented acetabular components and that these problems persist despite attempts to improve cementing technique. Cementless acetabular components that rely on biologic fixation can have lower rates of radiographic loosening at 10 years compared with cemented acetabular components. Although revision rates for both modes of fixation are largely equivalent at 10 years, the superior radiographic performance of cementless acetabular components at 10 years suggests that biologic fixation through bone ingrowth may provide more durable long-term implant survival compared with cemented fixation. Osteolysis is the major obstacle to long-term cementless acetabular component survival. Potential future options that may inhibit osteolysis include decreasing bone resorption that results from debris-stimulated foreign body response through the use of medications; decreasing the number of particles generated by using alternative bearing surfaces; and improving bone ingrowth, particularly through the use of growth factors and improved implant materials and designs.  相似文献   

10.
The need for revision total hip arthroplasty after metal-to-metal articulating prostheses is well known. An alternative to conventional acetabular revision in the clinical circumstance of isolated femoral component loosening is in vivo construction of a metal-backed, high-molecular-weight polyethylene (HMWPE) acetabular component. This surgical approach reduces the likelihood of intraoperative acetabular bone loss, should minimize subsequent loosening, and virtually eliminates the source of metallic wear debris. Follow-up evaluation after 3 years revealed maintenance of the acetabular component position and a satisfactory clinical result. In vivo construction of a metal-backed HMWPE acetabular component is an effective alternative in the management of this potentially difficult orthopedic problem.  相似文献   

11.
BACKGROUND: Second-generation cementless femoral components were designed to provide more reliable ingrowth and to limit distal osteolysis by incorporating circumferential proximal ingrowth surfaces. We examined the eight to eleven-year results of total hip arthroplasty with a cementless, anatomically designed femoral component and a cementless hemispheric acetabular component. METHODS: Ninety-two consecutive primary total hip arthroplasties with implantation of a femoral component with a circumferential proximal porous coating (Anatomic Hip) and a cementless hemispheric porous-coated acetabular component (Harris-Galante II) were performed in eighty-five patients. These patients were prospectively followed clinically and radiographically. Six patients (seven hips) died and five patients (seven hips) were lost to follow-up, leaving seventy-four patients (seventy-eight hips) who had been followed for a mean of ten years (range, eight to eleven years). The mean age at the time of the arthroplasty was fifty-two years. RESULTS: The mean preoperative Harris hip score of 51 points improved to 94 points at the time of final follow-up; 86% of the hips had a good or excellent result. Thigh pain was reported as mild to severe after seven hip arthroplasties. No femoral component was revised for any reason, and none were loose radiographically at the time of the last follow-up. Two hips underwent acetabular revision (one because of dislocation and one because of loosening). Kaplan-Meier survivorship analysis was performed with revision or loosening of any component as the end point. The ten-year survival rate was 96.4% +/- 2.1% for the total hip prosthesis, 100% for the femoral component, and 96.4% +/- 2.1% for the acetabular component. Radiolucencies adjacent to the nonporous portion of the femoral component were seen in sixty-eight (93%) of the -seventy-three hips with complete radiographic follow-up. Femoral osteolysis proximal to the lesser trochanter was noted in four hips (5%). No osteolysis was identified distal to the lesser trochanter. Periacetabular osteolysis was identified in twelve hips (16%). Five patients underwent exchange of the acetabular liner because of polyethylene wear. CONCLUSIONS: This second-generation cementless, anatomically designed femoral component provided excellent clinical and radiographic results with a 100% survival rate at ten years. The circumferential porous coating of this implant improved ingrowth and prevented distal osteolysis at a mean of ten years after the arthroplasty.  相似文献   

12.
Survivorship analysis of 1,041 cemented Charnley total hip arthroplasties performed as a primary procedure revealed a probability of component survival at 10 years of 92%; the probability of acetabular cup survival was 99% and of femoral component survival was 96%. Three-zone acetabular demarcation was present in 16% of cases, as was migration of the cup greater than 5 mm. However, the acetabular revision rate was 1.65%, confirming the long-term clinical durability of the 22-mm internal diameter cup. Radiographic evidence of definite femoral component loosening was present in 9.6% and high-grade femoral bone-cement demarcation was present in 3.5%. The isolated femoral revision rate was 1.8%. Based on detailed survivorship analysis, a high-risk group of patients was identified for component failure and for femoral component loosening (radiographic). These patients were male, young (less than 50 years), heavy (greater than 170 pounds), and active (not Charnley class C). Given these findings, it is difficult to justify the widespread use of noncemented total hip systems, except in identifiable high-risk patients.  相似文献   

13.
We present the long-term results (mean follow-up, 11.8 years; range, 6.3-15.4 years) of cemented total hip arthroplasty with acetabular bulk bone grafting in 147 dysplastic hips using improved surgical techniques. Operations were performed through a direct lateral approach with partial trochanteric osteotomy to avoid nonunion of the greater trochanter. Bioresorbable poly(l-lactide) screws were used for fixation of the acetabular bone grafts to prevent any possible delayed remodeling. Preoperative planning using computer simulation was performed to estimate the optimal size and position of the acetabular component. Analysis predicted rates of survival of the acetabular component of 96% and 91% at 15 years, with revision for aseptic loosening and radiologic loosening as the end points, respectively. Our results indicate excellent long-term clinical and radiographic survivorship of a cemented acetabular component with bulk autograft for acetabular dysplasia.  相似文献   

14.
《The Journal of arthroplasty》2020,35(4):1042-1047
BackgroundThere is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years.MethodsClinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known.ResultsMean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher’s disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years–stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis.ConclusionThe Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.  相似文献   

15.
16.
文立成  李军  马忠泰 《中华外科杂志》2009,47(24):1888-1891
目的 对H/G非骨水泥人工全髋关节置换术后聚乙烯内杯的磨损及髋臼周围骨溶解的情况进行总结.方法 我院1991至1995年共进行58例(65髋)H/G非骨水泥人工全髋关节置换,其中35例(40髋)获得10年以上随访.对这35例(40髋)患者获得随访的病例,采用计算机数字化方法测量髋臼聚乙烯内杯的二维线性磨损.结果 35例40髋均有不同程度的磨损,磨损范围2~8 mm,平均磨损为(0.32±0.31)mm/年.10髋聚乙烯磨损超过6 mm,髋臼假体周围的骨溶解严重,并伴有金属假体的移位,其中5髋聚乙烯内杯完伞磨透,金属股骨头与金属髋臼相接触;5髋聚乙烯内杯磨损严重伴明显骨溶解,内杯松动.2髋聚乙烯内杯脱位.共实施翻修手术12例,包括更换聚乙烯内杯和金属股骨头2例、金属闩杯翻修2例、全髋翻修8例.28髋在髋臼侧发现骨溶解,其中14髋股骨侧亦有骨溶解发生.结论 本组病例所观测到的H/G髋臼聚乙烯内杯的磨损程度超过文献所报道,而且由于磨损产生的大量磨屑,导致假体周围出现明显骨溶解,直接影响到假体的稳定.关节置换术后应定期随访,避免出现严重骨溶解后增加翻修手术的困难.  相似文献   

17.
BACKGROUND: We have been using hybrid total hip arthroplasty (a cementless acetabular component and a cemented stem) in young patients. The purpose of this study was to determine the prevalence of aseptic loosening, polyethylene wear, and osteolysis after the use of this technique. METHODS: We studied a prospective consecutive series of sixty-four primary hybrid total hip replacements in fifty-five patients younger than fifty years old. There were forty-three men and twelve women; the average age at the time of the index operation was 43.4 years. The average duration of follow-up was 9.4 years. We used a cementless acetabular component without screw-holes and a cemented femoral component with a 22-mm head in all hips. Clinical follow-up with use of Harris hip ratings and radiographic follow-up were performed at six weeks; at three, six, and twelve months; and yearly thereafter. The sequential annual linear and volumetric wear rates were measured, and bone-remodeling and osteolysis were assessed. RESULTS: The mean preoperative Harris hip score was 44 points, which increased to 95 points at the time of final follow-up. No hip had aseptic loosening. One hip (2%) was revised because of late infection. The average linear wear (and standard deviation) was 0.96 +/- 0.066 mm, with an average annual rate of 0.096 +/- 0.013 mm. The average volumetric wear was 364.7 +/- 25.2 mm (3), with an average annual rate of 43.4 +/- 3.5 mm (3). Six hips (9%) had an osteolytic lesion of <1 cm in diameter in the calcar femorale (zone 7). CONCLUSIONS: Our results show that a hybrid arthroplasty with a cementless acetabular component and a smooth cemented femoral component (Ra, 0.6 mm) is effective for primary total hip replacement in young patients. Although there was no aseptic loosening and a low prevalence of osteolysis at the latest follow-up evaluation, the high rates of linear and volumetric wear of the polyethylene liner in these young patients remain a concern.  相似文献   

18.
Intermediate and long-term results of revision total hip arthroplasty performed with the use of a cemented acetabular component have been disappointing, with high rates of radiographic and clinical failure. Other methods of acetabular revision involving the use of threaded cups and bipolar implants have also met with high failure rates. Although the long-term results of revision arthroplasty with uncemented acetabular components, especially in terms of polyethylene wear and pelvic osteolysis, are not yet available, the intermediate results have been excellent.  相似文献   

19.
Between 1971 and 1980, the senior one of us (C.S.R.) performed 101 primary total hip replacements in eighty-five consecutive patients who were less than fifty-five years old. All of the patients had degenerative joint disease. Survivorship analysis was used to calculate a predicted cumulative rate of success for this series of total hip replacements over ten years of follow-up. This method of analysis of the data was chosen because it provides a prediction of the expected durability of a total hip arthroplasty in any individual patient. The need for revision because of loosening or infection or else radiographic evidence of migration of a component was the criterion for failure. Two revisions were performed for aseptic loosening of the acetabular component. One infection necessitated revision, and radiographic evidence of loss of fixation was seen in one additional acetabular component and one femoral stem. Life-table calculations predicted that the survivorship of all of the total hip replacements in this series would be 87.6 per cent at ten years of follow-up. Based on the results of the application of this method of analysis to the current series, we concluded that a primary cemented total hip replacement, when performed for coxarthrosis, can be expected to function durably in an active middle-aged patient.  相似文献   

20.
We evaluated the use of a stemmed acetabular component in the treatment of severe acetabular deficiency during revision and complex primary total hip arthroplasty. There were 31 hips of which 24 were revisions (20 for aseptic loosening, four for infection) and the remainder were complex primary arthroplasties. At a mean follow-up of 10.7 years (6 to 12.8), no component had been revised for aseptic loosening; one patient had undergone a revision of the polyethylene liner for wear. There was one failure because of infection. At the latest follow-up, the cumulative survival rate for aseptic loosening, with revision being the end-point, was 100%; for radiographic loosening it was 92% and for infection and radiographic loosening it was 88%. These results justify the continued use of this stemmed component for the reconstruction of severe acetabular deficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号