首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: Use of extracorporeal systems in cardiopulmonary bypass and dialysis induces vascular reactions, which can lead to hypotension and lung edema. METHODS: To study the contribution of blood-material contact and use of a roller pump, as well as prevention of their adverse effects, we perfused a rat hind leg with a tube connecting a carotid and a femoral artery. RESULTS: Autoperfusion of an uncoated tube caused a fall of aortic pressure and femoral resistance to 66% +/- 16% and 76% +/- 15%, respectively, of their initial values within 2 hours, whereas in control animals without a shunt, these variables hardly changed (to 94% +/- 2.8% and 99% +/- 2.8%, respectively). Lung water content became significantly higher than that found in control animals (79.4% +/- 1.50% versus 77. 0% +/- 1.67%). If we coated the tube with albumin, these changes were largely prevented. When the coated tube was placed in a roller pump, aortic pressure and femoral resistance immediately fell to 79% +/- 17.2% and 63% +/- 13.5%, respectively, whereas lung water content did not increase. The vasodilation was caused by platelet aggregation and could be prevented with aurintricarboxylic acid, which inhibits shear-induced platelet aggregation by blocking the binding of von Willebrand factor to platelet glycoprotein Ib receptors. CONCLUSIONS: Extracorporeal circulation may induce hypotension and lung edema by means of blood-material contact. Hypotension can be prevented by coating the system with albumin but can still result from pump-induced platelet aggregation.  相似文献   

2.
Cardiopulmonary surgeries need connectors for extracorporeal circulation. The patient's blood in contact with the tube surfaces modifies its plasmatic proteins, promotes platelet aggregation, and activates the complement system, unleashing thrombus formation. Thus, it becomes necessary for an anticoagulant to keep the circuit free from these events. Heparin is the anticoagulant used even after reports about its disadvantages. Platelet adherence seems to be very dependent on the quality from the surfaces that can promote cellular proliferation, aggregation, and thrombosis. In this study, we compare the quality of the heparin-coated and uncoated surfaces. We used a blood cell culture and scanning electron microscopy (SEM) to visualize the platelet aggregation. It was concluded that there are groove areas that permit platelet adherence, and if they are not coated totally by the heparin, aggregation still occurs although in lower scale than on the uncoated tubes.  相似文献   

3.
The effect of hemoperfusion over charcoal on changes in platelet counts, coagulation factor concentrations and standard coagulation tests were determined during a two-hour in vitro perfusion of normal blood through a column containing 20 gm of activated charcoal, either uncoated or coated with 0.5% acrylonitrile/dimethylaminoethyl methacrylate copolymer (AN/DMAEMA). With citrated whole blood, platelet counts fell by 15% during hemoperfusion over coated or uncoated charcoal and also during passage through an identical empty chamber. On the other hand, with heparinized whole blood, platelet counts fell by 90% during hemoperfusion over uncoated charcoal, and 25% during hemoperfusion over coated charcoal. The concentrations of coagulation factors II, V, IX, X and XII were reduced during hemoperfusion over uncoated charcoal, while those of factors II and X were reduced and that of factor VII increased during hemoperfusion over coated charcoal. Perfusion with heparinized, platelet-rich plasma resulted in small reductions in platelet counts, suggesting that either erythrocyte disruption or the physical effects of intact red cells play a major role in producing the hemostatic abnormalities occurring during whole blood hemoperfusion. The method described may be used to assess the hemocompatibility of polymer coatings for charcoal particles, to investigate the nature of the interaction between platelets and artificial surfaces, and to assess the effect of platelet-active agents in reducing platelet adsorption on charcoal or other sorbents.  相似文献   

4.
OBJECTIVE: Otorrhea and tube occlusion are typical problems with tympanostomy tubes (TT). The purpose of this study was to test glue protein, fibronectin adhesion on albumin-coated and uncoated TT surfaces and to show the effect of this method on TT sequelae in vivo. STUDY DESIGN AND SETTINGS: Fibronectin binding on TT surface was tested in two in vitro experiments. Thereafter 170 patients were randomized in a prospective clinical trial to test the effect of the method in vivo. The extruded TTs that could be collected from ears of some study patients were imaged with scanning electron microscopy (SEM). RESULTS: Marked binding inhibition of fibronectin on albumin-coated TTs was found. Fewer tube sequelae were found in ears with albumin-coated TTs. SEM revealed thick crusts on uncoated tube surface. CONCLUSION: Albumin coating of TTs can reduce unwanted adhesion on the tube surface in vitro and tube occlusions in vivo. SIGNIFICANCE: TT sequelae can be reduced by surface coating with albumin.  相似文献   

5.
OBJECTIVES: To compare the effects of centrifugal pumps versus roller pumps for cardiopulmonary bypass (CPB) in routine cardiac surgery on hematologic parameters in the context of modern practice. DESIGN: Prospective, randomized, partially blinded. SETTING: University teaching hospital. PARTICIPANTS: Elective coronary artery surgery patients (n = 113) INTERVENTION: Patients were randomized to be perfused with either a roller head (group R, n = 56) or a centrifugal head (group C, n = 57) pump. Patients received epsilon-aminocaproic acid before and during CPB. Core body temperatures were allowed to drift down to approximately 32 degrees C. MEASUREMENTS AND MAIN RESULTS: Postoperative chest tube blood loss, blood product requirements, hemoglobin, and platelet counts were assessed. There were no significant differences in preoperative or intraoperative parameters, including CPB time, complexity of procedure, and minimum core temperature. There were the expected reductions in hemoglobin and platelet levels post-CPB in both groups to a similar extent. Chest tubes remained in situ for similar durations, and the final volume of drainage was not significantly different (group C, 1300 +/- 92 mL; group R 1117 +/- 83 mL; p = 0.14). Allogeneic blood was given to 23% of patients in group C and 18% in group R (p = 0.63). Aspirin was associated with an increase in early chest tube drainage. CONCLUSIONS: In this surgical and perfusion environment, the authors were unable to show an advantage, from the hematologic point of view, in the routine use of a centrifugal pump head in elective coronary artery surgical patients. The use of antifibrinolytic agents and mild hypothermia may have effects on hemostasis that overshadow the influence of pump head design in this type of surgery.  相似文献   

6.
Abstract: The effects of pulsatile and nonpulsatile cardiopulmonary bypass using a roller pump on levels of vasoactive hormones and hematologic changes were studied in 32 patients subjected to elective primary coronary artery bypass graft surgery. Seventeen patients had nonpulsatile perfusion (nonpulsatile group) and 15 patients had pulsatile perfusion (pulsatile group) during the period of cardiac arrest. Vasoactive hormones (plasma renin, angiotensin II, aldosterone, epinephrine, and norepinephrine) were measured in these patients. In order to clarify hematologic changes, plasma free hemoglobin, number of platelets, platelet factor 4, and β -thromboglobulin were measured. There were no significant differences between the pulsatile and nonpulsatile groups with regard to vasoactive hormones and damage of platelets. In the pulsatile group, however, the rise of plasma free hemoglobin levels was significantly higher than that in the nonpulsatile group during and after cardiopulmonary bypass. We did not see the benefit of pulsatile perfusion using a roller pump on vasoactive hormones. Evidence of increased hemolysis with pulsatile flow was demonstrated in our cases.  相似文献   

7.
BACKGROUND: Hemorrhage is a major complication of trauma and often becomes more severe in hypothermic patients. Although it has been known that platelets are activated in the cold, studies have been focused on platelet behavior at 4 degrees C, which is far below temperatures encountered in hypothermic trauma patients. In contrast, how platelets function at temperatures that are commonly found in hypothermic trauma patients (32-37 degrees C) remains largely unknown, especially when they are exposed to significant changes in fluid shear stress that could occur in trauma patients due to hemorrhage, vascular dilation/constriction, and fluid resuscitation. METHODS: Using a cone-plate viscometer, we have examined platelet activation and aggregation in response to a wide range of fluid shear stresses at 24, 32, 35, and 37 degrees C. RESULTS: We found that shear-induced platelet aggregation was significantly increased at 24, 32, and 35 degrees C as compared with 37 degrees C and the enhancement was observed in whole blood and platelet-rich plasma. In contrast to observation made at 4 degrees C, the increased shear-induced platelet aggregation at these temperatures was associated with minimal platelet activation as determined by the P-selectin expression on platelet surface. Blood viscosity was also increased at low temperature and the changes in viscosity correlated with levels of plasma total protein and fibrinogen. CONCLUSION: We found that platelets are hyper-reactive to fluid shear stress at temperatures of 24, 32, and 35 degrees C as compared with at 37 degrees C. The hyperreactivity results in heightened aggregation through a platelet-activation independent mechanism. The enhanced platelet aggregation parallels with increased whole blood viscosity at these temperatures, suggesting that enhanced mechanical cross-linking may be responsible for the enhanced platelet aggregation.  相似文献   

8.
To facilitate perfusion rewarming without the use of total body heparinization or an oxygenator following open-heart correction with surface hypothermia, we divised a pump circuit. The circuit, totally primed with 100 c.c. of saline, consists of polyurethane-polyvinyl-graphite (PPG) coated Tygon tubes (with one end tapered by heat treatment) and a copper-coil heat exchanger. A roller pump was used to achieve partial bypass from the left atrium to the ascending aorta with flow rates up to 70 c.c. per kilogram per minute. Experiments in dogs resulted in rapid rewarming, immediate return of cardiac function, and hematologic alterations similar to those noted during surface rewarming. The safety of the method was also demonstrated. Prothrombin time, partial thromboplastin time, and platelet values returned to control levels upon rewarming, and no thromboemboli or bleeding problems were noted. Six clinical experiences were accumulated. Details of the method, hematologic and blood chemical analyses in dogs, and the first clinical trial in a 3-month-old infant with transposition of the great vessels are reported.  相似文献   

9.
The influence of early graft surface thromboreactivity on long-term arterial polyester (Dacron) graft patency was investigated with separate ex vivo and in vivo animal models. First, parallel, flow-regulated external aortocaval fistulae were created in five pigs with use of paired 8 mm X 35 cm crimped, warp-knitted, low-profile filamentous velour Dacron tubes: one tube preclotted with autologous blood, the other autoclaved after being soaked in human albumin. Autologous radiolabeled platelets, red cells, and radiolabeled human fibrinogen were injected at initiation of graft flow, with timed graft samples submitted for isotope gamma well-counting. Flow surface accumulation of radiolabeled blood elements was greater on the preclotted graft limb at-all time intervals studied, greatest after 5 minutes of flow initiation with RBC accumulation on the preclotted limb 5.19 +/- 0.84 (x +/- S.E.), platelet accumulation 5.57 +/- 1.00, and fibrinogen accumulation 1.82 +/- 0.14 times greater than that on the albumin-treated limb. Second, bilateral iliofemoral artery bypass grafts were placed in 12 mongrel dogs using 6 mm X 10 cm externally supported, noncrimped, warp-knitted, low-profile filamentous Dacron tubes. Before implant in each dog, one graft limb was clotted with autologous blood and the other was autoclaved after being soaked in 25% human albumin. Fresh autologous radiolabeled platelets were injected after wound closure in seven of these dogs. Postimplant graft imaging at 24 and 72 hours showed radiolabeled platelet accumulation to be 1.43 +/- 0.21 and 2.05 +/- 0.18 times greater on the preclotted graft limb. Six of 12 preclotted graft limbs and 7 of 12 albumin-treated graft limbs were patent when animals were killed 5 to 6 months after implant (not significant). Heat-denatured albumin-coated Dacron surfaces have a reduced early thromboreactivity but do not appear to greatly potentiate long-term arterial graft patency.  相似文献   

10.
Shear-induced platelet activation (SIPA) has been identified to induce platelet adhesion and thrombus formation in continuous flow left ventricular assist devices (LVAD). Platelet glycoprotein (GP) IIb/IIIa receptor inhibitors are effective to prevent SIPA. However, systemic GP IIb/IIIa receptor inhibitor application is associated with severe bleeding complications. The aim of the study was to evaluate (i) the feasibility of absorption and elution of the GP IIb/IIIa receptor blocker TAK-029 from the Ti6Al4V surface of the pump; and (ii) the effect of local GP IIb/IIIa receptor blocker delivery regarding platelet adhesion on the surface of a continuous flow VAD model. Saturating concentrations of TAK-029 were adsorbed on the surface of a centrifugal pump. Whole human blood was perfused in circulatory mock loops using untreated (control), albumin-coated, or TAK-029-coated pumps. Peripheral resistance of the circulatory systems were adjusted accordingly to generate 5 L flow per min with impeller rotational speeds of 3500 (high-shear group) and 1500 rpm (low-shear group), respectively. Platelet adhesions on the respective impellers were quantified by ELISA and scanning electron microscopy (SEM). TAK-029 elution and half-life time were determined by ELISA. Compared with control, albumin-coated pumps showed 64 and 20% less platelet adhesions in the high- and low-shear group, respectively. TAK-029 coated pumps reduced platelet adhesion by additional 33 and 65%, respectively, compared with the albumin group. Elution of TAK 029 was initially very rapid and continued slowly. The results show that it is possible to adsorb and elute a small molecular weight GP IIb/IIIa receptor blocker from the pump surface. This drug elution reduced platelet adhesion on the pump significantly. Further studies are necessary to find a suitable drug bonding that will prolong the antiplatelet effect and preclude any bleeding complication caused by this procedure.  相似文献   

11.
The first roller pump was patented in 1855 by Porter and Bradley and was hand operated. A modification first named "surgical pump", designed and manufactured by E. E. Allen in 1887, was intended for direct blood transfusion. Truax, who also distributed and promoted the Allen pump with one roller, developed the first double roller pump in 1899. In the following decades, several researchers, including Beck, Van Allen, Bayliss and Müller as well as Henry and Jouvelet, refined the apparatus and recommended the use of roller pumps for blood transfusion and other applications. After further modifications made by DeBakey in 1934, and application of this pump in one of the first heart-lung machines constructed by Gibbon, DeBakey's name became inseparably attached to this type of pump. For perfusion experiments, an electrically powered roller pump was first used by Fleisch in 1935. Today, the roller pump is the most frequently used blood pump for cardiopulmonary bypass worldwide, having prevailed against the early pulsatile tube compression pumps and ventricular pumps. In recent years, centrifugal pumps have increasingly competed with roller pumps as systemic blood pumps for cardiopulmonary bypass and have become the preferred arterial pump in a variety of centers. Application of mechanical cardiac assistance has evolved from nonpulsatile roller pump support, followed by an era of pulsatile ventricular pumps to the rediscovery of the nonpulsatile flow mode with modern axial flow pumps.  相似文献   

12.
Objective--Evaluation of the centrifugal pump vs roller pump concerning effects upon platelet function, hemolysis and clinical outcome in elective coronary artery bypass surgery. Design--Thirty-four patients were randomized to centrifugal or roller pump. Platelet activation was studied by flow cytometry before, during and up to 3 days after bypass. Results--Duration of bypass, ischemic period, peripheral anastomoses, hospital stay and mortality did not differ. In roller pump patients, platelet aggregates increased by 250% between end of bypass and 3 h postoperatively (p < 0.001). A secondary, fivefold increase in number of platelet aggregates was found on the 3rd postoperative day (p < 0.001). In the centrifugal pump group, these changes were not significant. Hemolysis increased (20%) at end of bypass and 3 h postoperatively (p < 0.005), and decreased to preoperative levels the next day without group difference. Conclusion--Platelet aggregation was significantly increased in roller compared with centrifugal pump patients, indicating higher susceptibility to postoperative thrombotic complications with the roller pump. Otherwise, there was no clinical evidence for superiority of the centrifugal pump.  相似文献   

13.
OBJECTIVES: Nitric oxide (NO), produced by normal vascular endothelial cells, reduces platelet aggregation and thrombus formation. NO-releasing biopolymers have the potential to prolong vascular graft and stent patency without adverse systemic vasodilation. METHODS: 5-mm polyurethane vascular grafts coated with a polymer containing the NO-donor dialkylhexanediamine diazeniumdiolate were implanted for 21 days in a sheep arteriovenous bridge-graft model. RESULTS: Eighty percent (4/5) of grafts coated with the NO-releasing polymer remained patent through the 21 day implantation period, compared to fifty percent (2/4) of sham-coated grafts and no (0/3) uncoated grafts. Thrombus-free surface area (+/-SEM) of explanted grafts was significantly increased in NO-donor coated grafts (98.2% +/- 0.9%) compared with sham-coated (79.2% +/- 8.6%) and uncoated (47.2% +/- 5.4%) grafts ( P = .00046). Examination of the graft surface showed no adherent thrombus or platelets and no inflammatory cell infiltration in NO-donor coated grafts, while control grafts showed adherent complex surface thrombus consisting of red blood cells in an amorphous fibrin matrix, as well as significant red blood cell and inflammatory cell infiltration into the graft wall. CONCLUSION: In this study we determined that local NO release from the luminal surface of prosthetic vascular grafts can reduce thrombus formation and prolong patency in a model of prosthetic arteriovenous bridge grafts in adult sheep. These findings may translate into improved function and improved primary patency rates in small-diameter prosthetic vascular grafts.  相似文献   

14.
15.
Asberg AE  Videm V 《Artificial organs》2005,29(12):927-936
Activated neutrophils play a central role in the pathogenesis of postoperative organ dysfunction after surgery with cardiopulmonary bypass. The researchers used an in vitro roller pump model to investigate the relative importance of the biomaterial, platelets, plasma proteins including activated complement, and flow mode on neutrophil activation as shown by the adhesion, degranulation, and increased the surface expression of CD11b. Neutrophil adhesion to the biomaterial increased with platelet addition, but not with plasma. Biomaterial contact activated neutrophils in a serum-free buffer, but was significantly increased by activated complement. Platelets increased neutrophil degranulation in a serum-free buffer but tended to reduce it in plasma. CD11b expression increased in both media. Complement activation was higher with neutrophils alone than with neutrophils and platelets combined. The roller pump reduced neutrophil adhesion and increased degranulation compared to passive rotation. Neutrophil interaction with platelets and complement were more important for activation than biomaterial contact and use of the roller pump. Improvement of biocompatibility is dependent on modifying complement activation and platelet interaction with neutrophils.  相似文献   

16.
BACKGROUND: Ischemia from tissue hypoperfusion in the gastric tube after esophagectomy is believed to contribute significantly to postoperative complications associated with anastomotic failure. This study assessed the ability of the new technique of laser Doppler flowmetry to measure differential levels of blood flow in human gastric tubes during esophagectomy. STUDY DESIGN: Gastric perfusion was measured in 16 patients undergoing esophagectomy by making laser Doppler scans of the stomach before mobilization and after formation of the gastric tube. Mean perfusion was calculated within the whole anterior surface of the stomach or tube and within 1 cm2 regions of interest, each of which contained 1,750 individual measurements of perfusion. These regions represented the cephalic end of the gastric tube, 10 adjacent 1 cm2 regions distally along the tube, and the proposed anastomosis site. Results were expressed as mean perfusion units, and tissue blood flow from each scan in each region was compared. RESULTS: There were significant decreases in gastric perfusion measured with the scanning laser Doppler in all patients after formation of the gastric tube. Mean perfusion of the stomach fell 41% (p<0.0005) after mobilization. In all patients there was a gradient of perfusion from the proximal end of the tube where flow was poor, to more distal areas where it was higher. At the proximal end of the tube perfusion fell by a mean of 72%, 5 cm distally the mean fall was 44%, and 10 cm from the proximal end of the tube the mean fall was 28%. At the anastomosis site mean perfusion fell 55%. CONCLUSIONS: This new technique can be used intraoperatively and appears to overcome the limitations of single point laser Doppler flowmetry. It has measured large differences in perfusion at different sites within the gastric tubes and could therefore have widespread clinical applications.  相似文献   

17.
Abstract: A centrifugal pump with an impeller (Nikkiso Centrifugal Pump, Model HPM15; Nikkiso Co. Ltd.) was applied to cardiopulmonary bypass (CPB) in 14 patients who underwent elective coronary artery bypass grafting. Serum hemoglobin level, platelet count, and serum p-thromboglobulin (pTG) level were measured during CPB. The results were compared with those obtained in a comparative roller pump (RP) group (n = 10). There was no difference in the time on CPB between the NP (109 min) and RP (121 min) groups. The serum pTG level (ng/ ml) was lower in the NP group than in the RP group (obtained 90 min after the initiation of CPB). The plasma-free hemoglobin level also was lower in the NP group than in the RP group (obtained 90 min after the initiation of CPB, 120 min after the initiation of CPB, immediately after the termination of CPB, 3 h after termination of CPB; p < 0.01). There was no significant difference in platelet depletion. The HPM15 pump showed excellent hemodynamic performance with less blood trauma compared with the roller pump in its clinical application to open heart surgery.  相似文献   

18.
Pump thrombosis potential exists in most blood pumps and limits their clinical use. To improve the pump thrombosis performance of blood pumps, a method for emulating the platelet deposition on the flow passage component surfaces inside blood pumps was presented and tested. The method emulates the blood platelet deposition, employing laser-induced fluorescence tracing technology. The blood pump was rotated in a mock circulation loop with deionized water filled with fluorescent particles. The component surfaces were then explored via laser. The fluorescent particles were induced by laser and imaged in a charge-coupled device (CCD) camera to show the distribution of fluorescent particles gathering on the blood pump component surfaces. The activated platelet deposition was emulated by fluorescent particle gathering. The experiment showed obvious particle gathering on the interface surfaces and cross-sectional surface (perpendicular to the flow). This platelet deposition estimation (PDE) method can be easily incorporated in the in vitro testing phase to analyze and decrease a pump’s thrombosis potential before animal experimentation, thereby reducing the cost of blood pump development. This methodology of emulating blood platelet deposition indicates its potential for improving flow passage component structure and reducing device thrombosis of blood pumps.  相似文献   

19.
Background : Inhibitory effects of volatile anaesthetics on platelet aggregation have been demonstrated in several studies. However, the influence of volatile anaesthetics on intracoronary platelet adhesion has not been elucidated so far.
Methods : Isolated hearts of guinea pigs were perfused with buffer in the absence or presence of volatile anaesthetics (0.5 and 1 MAC) at constant coronary flow rates of 5 ml/min for 25 min, then 1 ml/min for 30 min and again 5 ml/min for 10 min. Before, during and after low-flow perfusion, a bolus of human platelets was applied into the coronary system. To simulate thrombogenic conditions, 0.3 U/ml human thrombin was infused during low-flow perfusion and reperfusion. The number of platelets sequestered to the endothelium was calculated from the difference between coronary in- and output of platelets. The myocardial production of lactate and consumption of pyruvate and coronary perfusion pressure were also determined.
Results : At a flow rate of 5 ml/min only about 3% of the applied platelets did not emerge from the coronary system, in any group. In contrast, 13.1±1.2% (mean±SEM) of infused platelets became adherent in low-flow perfusion in the control group without anaesthetic. The adherence was reduced with each 1 MAC isoflurane (to 6.2±1.2%), sevoflurane (to 4.4±0.9%) or halothane (to 3.2±1.5%) (each P <0.05 vs. control). Volatile anaesthetic, 0.5 MAC, did not inhibit platelet adhesion to a statistically significant extent in any case. Perfusion pressure and metabolic parameters were not statistically different between the control and the hearts exposed to anaesthetics.
Conclusion : Volatile anaesthetics in a concentration of 1 MAC can reduce the adhesion of platelets in the coronary system under reduced flow conditions. This action does not arise from vasodilation or inhibition of ischaemic stress.  相似文献   

20.
OBJECTIVE: To determine if normal cardiopulmonary bypass (CPB) pump flows maintain cerebral perfusion in the context of reduced mean arterial pressure at 33 degrees C. DESIGN: A prospective investigation. SETTING: Animal CPB research laboratory. PARTICIPANTS: Seven dogs that underwent CPB. INTERVENTIONS: Seven dogs underwent CPB at 33 degrees C using alpha-stat management and a halothane, fentanyl-midazolam anesthetic. Cerebral blood flow was measured using the sagittal sinus outflow technique. After control measurements at 70 mm Hg, cerebral physiologic values were determined under four conditions in random order: (1) mean arterial pressure of 60 mm Hg achieved by a reduction in pump flow, (2) mean arterial pressure of 60 mmHg determined by partial opening of a femoral arterial-to-venous reservoir shunt, (3) mean arterial pressure of 45 mm Hg by reduced pump flow, and (4) mean arterial pressure of 45 mm Hg by shunt. A 9F femoral arterial-to-venous reservoir shunt was controlled by a screw clamp. MEASUREMENTS AND MAIN RESULTS: Except for the controlled variables of mean arterial pressure and bypass flow, physiologic determinants of cerebral blood flow (temperature, PaCO2 and hematocrit) did not differ under any of the CPB conditions. Pump flow per se was not a determinant of cerebral perfusion. Cerebral blood flow and cerebral oxygen delivery did not differ with changes in pump flow if mean arterial pressure did not differ. Cerebral blood flow depended on mean arterial pressure under all pump flow conditions, however. CONCLUSIONS: Over the range of flows typical in adult CPB at 33 degrees C, pump flow does not have an effect on cerebral perfusion independent of its effect on mean arterial pressure. A targeted pump flow per se is not sufficient to maintain cerebral perfusion if mean arterial blood pressure is reduced.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号