共查询到20条相似文献,搜索用时 31 毫秒
1.
Objective
Symptomatic distal interlocking screws in retrograde femoral nailing are common due the difficulties of imaging the trapezoidal femur. Screws appearing to have appropriate length on imaging may possibly be prominent, creating symptoms. Screw trajectory may influence the degree of this radiographic error. We hypothesize that external rotation of screw trajectory will increase measurement error of screw length.Design
Retrospective.Setting
Urban Level I Tertiary Trauma Center.Participants
283 patients with Computer Tomography (CT) scans of the native knee were retrospectively identified. Simulation was done of the trajectory of an interlock at 20?mm and 40?mm proximal to the nail entry point, which represent common screw positions associated/not associated respectively, with removal. The distance between the radiographic medial cortex and the tip of the transverse screw was calculated (D). The angle (Ψ) between the transverse trajectory and a modified trajectory aimed at the most medial cortex to avoid radiographic measurement error was calculated. Geometric modeling was utilized to calculate the measurement error (D) in the event of accidental external rotation. The angle of the medial slope was also measured (Θ).Intervention
Review of CT imaging of normal distal femora.Main Outcome Measurements
CT measurements of distal femora.Results
The mean distance (D) at 20/40?mm was 4.21 [95%CI 4.02–4.402] and 2.03?mm [95%CI 1.78–2.83], respectively (p?<?0.0001). The mean angle (Ψ) between the transverse and modified trajectory at 20/40?mm was 12° [95%CI 11.5–12.5] and 9.60° [95%CI 9–10.2], respectively (p?<?0.0001). External rotation by a similar amount nearly triples the measured difference (D). The measured medial slope was significantly increased as screws were placed more proximal (Θ20 mm 46.5 vs Θ40 mm: 48.7?°, p?<?0.00001).Conclusion
The distance between the perceived medial cortex and the tip of the most transverse screw is 4.21?mm and could account for painfully prominent screws. In more proximal screws this distance is decreased. Internal rotation of the screw trajectory 12° can reduce this distance (D), which has implications in nail design. External rotation, amplifies this difference nearly three-fold. Surgeons should avoid external rotation of the aiming arm to prevent prominent screws. 相似文献2.
Matthew R. Walker Ashraf N. El Naga Omar H. Atassi Christopher H. Perkins Scott A. Mitchell 《Injury》2019,50(3):686-689
Objectives
Hip dislocations are highly morbid injuries necessitating prompt reduction and post-reduction assessment for fracture and incarcerated fragments. Recent literature has questioned the need for initial pelvic radiographs for acute trauma patients, resulting in computed tomography (CT) scans as the initial evaluation. This study investigates the relationship between choice of pre-reduction imaging and treatment of acute hip dislocations.Design
Retrospective Case-Control.Setting
Single Academic Level I Trauma Center.Methods
All acute hip dislocations from 2011 to 2016 were reviewed. Exclusion criteria were diagnosis of dislocation at another facility, death prior to reduction, emergent surgical or ICU intervention, and periprosthetic dislocation. Patients were grouped by those with only a radiograph prior to reduction, Group I, versus those with a pre-reduction CT scan, Group II. The primary outcomes were time to reduction and the acquisition of a second CT scan.Results
Of the 123 hip dislocations identified, 35 patients were excluded, mostly for transfer with a known dislocation. Group I included 29 patients and Group II included 59 patients. The mean time to reduction was 74?min in Group I and 129?min in Group II for a difference of 55?min (p?<?0.001). The rate of repeat CT scan was 0 in Group I versus 48 (81%) in Group II (p?<?0.001).Conclusion
Initial trauma pelvic radiography prior to CT is still important in the setting of suspected hip pathology to decrease time to hip reduction and unnecessary radiation exposure.Level of evidence
Prognostic Level III. 相似文献3.
Christina Liu Arvind Von Keudell Michael McTague Edward K. Rodriguez Michael J. Weaver 《Injury》2019,50(3):727-732
Background
It is common practice when placing cannulated screws within the femoral head when treating femoral neck fractures to avoid the thread-forms from crossing the fracture line. Despite the widespread use of cannulated screws in internal fixation of femoral neck fractures, there is no study to our knowledge that describes the ideal length of thread-forms.Purpose
The purpose of this study is to determine the thread length that will maximize purchase within the femoral head while minimizing risk of crossing the fracture line. Additional analysis was conducted to identify factors associated with the maximal possible length of treads in minimally and non-displaced femoral neck fractures.Methods
We performed a retrospective study of all patients treated for a minimally or non-displaced femoral neck fracture from April 1, 2004 through December 31, 2017. Only patients who had received a pre-operative CT or MRI scan were included. Fixation was then templated using radiographs and the distance from the subchondral bone to the fracture line was then measured.Results
The study included 127 patients. The average estimated length of lag screw threads was 33.2?±?6.67?mm, with lower quartile of 29.1?mm and higher quartile of 37.2?mm. The median was 32.0?mm and most frequently encountered estimate was 29?mm. Estimated lag screw size did not differ significantly based on age or BMI, but both height (p?<?0.001) and race (0.04) were positively correlated with estimated lag screw size and males had longer measurements compared to females, 37.2?±?7.0?mm vs 31.4?±?5.7?mm (p?<?0.001), respectively.Conclusion
In conclusion, we propose an additional lag screw thread form with length 26.0?mm to capture 90% of femoral neck fractures. 相似文献4.
Objective
To analyse whether early post-operative full weight bearing following syndesmotic ankle fixation affected radiographic outcomes suggestive of diastasis.Design
Retrospective comparative cohort study over a two year period.Setting
Level 1 trauma centrePatients/Participants
152 consecutive patients sustaining an unstable ankle fracture requiring syndesmotic stabilisation were included. Exclusions were 49 patients who had trimalleolar fixation without syndesmosis screws, one patient who had concomitant ankle and talar fracture. Five patients were lost to follow up and eleven patients were followed up in other centres. A total of 86 patients were analysedIntervention
Protected or full weight bearing.Main Outcome Measurement
The primary outcome measure was early diastasis. The secondary outcomes were late diastasis, wound complications and re-operation. Analysis of variance was used for the predictor variable of weight bearing status. We assumed a priori that p values of less than 0.05 were significant.Results
Median age was 36 (IQR 30), with 54 males and 32 females. Median follow up was 12 weeks (IQR 6). There was no significant difference when comparing weight bearing status and change in radiographic measurements intra-operatively compared to 6 and 12 week follow up radiographs (tibiofibular clear space p?=?0.799, tibiofibular overlap p?=?0.733 and medial clear space p?=?0.261).Conclusion
After surgical stabilization of an unstable syndesmotic injury, full weight bearing did not lead to syndesmotic diastasis in the early post-operative period. Full weight bearing is recommended following ankle fixation which includes syndesmotic fixation. 相似文献5.
Ahmed Latif Baljinder S. Dhinsa Benjamin Lau Ali Abbasian 《Foot and Ankle Surgery》2019,25(2):132-136
Background
This study reports the outcome of a plating system for arthrodesis of the first metatarsophalangeal joint (1st MTPJ) that incorporates a lag compression screw within a low profile titanium plate with a predetermined contour. This is the first report of the outcomes of this implant from a non-affiliated centre.Patient and methods
This is a prospective cohort study of 40 consecutive primary 1st MTPJ arthrodesis procedures. The mean age of the cohort was 56 years (range, 20–74 years). The diagnosis was hallux rigidus in 31 patients and inflammatory arthropathy in 7 patients.Results
All patients achieved clinical union at 6 weeks and radiological union was confirmed on plain radiographs between 6–16 weeks. One case of hardware removal was reported.Conclusion
The cohort achieved consistently satisfactory results with a reliable and reproducible MTPJ position and a 100% union rate. There was a low rate of hardware removal.Level of evidence
Level IV evidence. Prospective cohort study. 相似文献6.
BaiHang Chen Chao Chen ZeTian Yang PeiZhen Huang Hang Dong ZhanPeng Zeng 《Foot and Ankle Surgery》2019,25(1):63-70
Background
To compare the efficacy between fixation with suture-button and screw in the treatment of syndesmotic injuries: a meta-analysis.Methods
We comprehensively searched PubMed, Embase, and the Cochrane Library and performed a meta-analysis of randomized controlled trials (RCTs) and retrospective comparative studies (RTCs). We performed using Review Manager 5.2.Results
Three RCTs and six retrospective studies were conducted, including a total of 397 patients. The significant differences of the fixation of suture-button were reported for AOFAS scores (at 3, 6 and 12 months follow-up), full-weight time, reoperation, malreduction and the rate of failure of fixation. There were no significant differences between the groups regarding complications of infection, VAS, OMAS, range of motion, TFCS, TFO and MCS.Conclusions
Neither the functional outcome nor complications significantly differed between the fixation methods, but suture-button might lead to a quicker return to work. This analysis needs to be confirmed and updated by larger sample data and rigorously designed RCTs. 相似文献7.
Alvin K. Shieh Motasem Refaat Nasser Heyrani Tanya C. Garcia-Nolen Mark A. Lee Jonathan G. Eastman 《Injury》2019,50(3):703-707
Objectives
Prophylactic femoral neck fixation may be performed in the setting of geriatric diaphyseal femur fracture, pathologic or impending atypical femur fractures. Fixation constructs often utilize cephalomedullary implants with one or two proximal interlocking screws into the femoral head/neck. Variations in proximal femoral anatomy and implant design can interfere with the placement of two screws in the femoral head and neck. Our objective was to assess the strength of piriformis entry reconstruction implants with one versus two proximal interlock screws for prophylactic femoral neck fixation.Methods
Thirty fourth generation synthetic femur models were separated into 5 groups. The control group was an intact femur, and the second group was an intact femur with an entry hole in the piriformis fossa. The remaining groups had an intramedullary nail placed with either 0, 1, or 2 screws placed into the femoral head and neck. Each femur was mechanically loaded along the mechanical axis through the femoral head. Load to failure and failure displacement were recorded.Results
Mean load to failure was 5583?±?543?N in the intact femur. Constructs with 2 screws had a significantly higher mean load to failure (3223?±?474?N) compared to one screw constructs (2368?±?280?N). All of the experimental groups remained significantly lower than the intact femur model (p?<?0.05).Conclusion
Our results demonstrate that piriformis entry reconstruction implants have a significantly lower load to failure compared to an intact femur irrespective of screw construct. Further studies are needed to investigate this potential iatrogenic weakening. 相似文献8.
Ichiro Tonogai Fumio Hayashi Yoshihiro Tsuruo Koichi Sairyo 《Foot and Ankle Surgery》2019,25(2):193-197
Background
The aims of this study were to identify the artery feeding the fifth metatarsal and determine how bunionette osteotomy could injure this vessel.Methods
The nutrient artery entering the fifth metatarsal was investigated in 10 adult cadaveric lower limbs by barium injection and enhanced computed tomography.Results
The nutrient artery entered the medial aspect of the fifth metatarsal around the junction of the middle and proximal thirds obliquely from a distal direction (mean?angle 36°) in the coronal plane in all cases; in the axial plane, the point of entry and direction of the artery was medial-plantar (mean?angle 49°).Conclusions
This report revealed direction and location of the nutrient artery entering the fifth metatarsal. 相似文献9.
Bahman SahraNavard Parke W. Hudson Cesar de Cesar Netto Bradley W. Wills Ibukunoluwa B. Araoye Shelby Bergstresser Brent M. Cone Ashish Shah 《Foot and Ankle Surgery》2019,25(1):84-89
Background
The number of screws used for sliding calcaneal osteotomy fixation has not been examined in the literature. The purpose of this paper is to examine this topic.Methods
Retrospective chart review was performed on 190 patients who met selection criteria. We compared complication risk for single versus double screw, headed versus headless screw, and short versus longitudinal incision cases.Results
The mean age was 48.4 (18–83) years and average follow up was 28 (12–150) weeks. All cases achieved radiographic union. Overall complication rate was 19.5% (37/190). Risk of complication did not differ significantly between single and double screw (RR: 1.170; 95% CI: 0.66–2.09; p = 0.594) or short and extended incision groups (RR: 0.868; 95% CI: 0.42–1.80; p = 0.704). Risk of complication differed significantly between headed and headless screw fixation (RR: 5.558; 95% CI: 2.69–11.50; p < 0.0001).Conclusions
Single screw fixation of sliding calcaneal osteotomy achieves similar outcomes as double screw fixation. Headless screws are advantageous for minimizing hardware pain and subsequent hardware removal. 相似文献10.
Background
Few methods have been described for measuring hindfoot alignment from an anteroposterior view. The objective of this study was to compare two methods of angular measurement based on the views of Meary and Saltzman.Methods
Thirty asymptomatic volunteers were included. Four radiographs were performed: the views of Meary and Saltzman with parallel feet and with the Fick correction. The reproducibility was determined by the inter- and intraobserver variability (ICC).Results
Meary’s method revealed a mean valgus angulation of 3.9° (SD 3.47°). The reliability was extremely variable with a mean ICC of 0.59. The best reproducibility was obtained with Meary’s method with and without Fick correction.Conclusion
The results of this study show that the reliability of the angular measurements depends on the radiographic view and measurement method chosen. The lateral Fick correction did not counteract the influence of tibial rotation. The same method should be used consistently. 相似文献11.
Byung-Ki Cho Ji-Kang Park Seung-Myung Choi Nelson F. SooHoo 《Foot and Ankle Surgery》2019,25(2):127-131
Background
This study was performed to evaluate the intermediate-term clinical outcomes after proximal chevron osteotomy for hallux valgus in patients with generalized ligamentous laxity, and to determine the effect on postoperative recurrence of deformity.Methods
There were 23 cases in laxity group (Beighton score ≥5 points) and 175 in non-laxity group with a mean followup of 46.3 months. Clinical evaluation consisted of the AOFAS score, Foot and Ankle Ability Measure (FAAM), and radiographic measurement of hallux alignment. Risk factors associated with postoperative recurrence were evaluated using univariate analysis.Results
Recurrence rates were 21.7% in the laxity group and 17.1% in non-laxity group (P = .218). There were no significant differences in clinical and radiographic measurements at final followup between the 2 groups. Preoperative HVA and IMA were found to be predictive factors of recurrence (OR = 6.3, 4.2; P = .001, .018, respectively).Conclusion
There were no statistical differences in the clinical and radiographic outcomes between hallux valgus with and without generalized ligamentous laxity. Generalized ligamentous laxity demonstrated no definitive effects on postoperative recurrence of hallux valgus deformity. 相似文献12.
Introduction
Surgery or trauma may induce extensive arthrofibrosis around joints and tendon for the restrictive range of motion. Although some approaches were proposed, this problem is not solved satisfactorily. Extracorporeal shock wave therapy (ESWT) has been used for orthopedic, musculoskeletal, and fibrotic disorders. Whether it could prevent the formation of arthrofibrosis during the joint repair is unknown.Methods
Intra-articular adhesions were created in the right knee of the rabbit by cortical bone shaving and subsequent cast immobilization. Arthrofibrosis in the control and ESWT group was evaluated and compared at week 4.Results
Macroscopic score of arthrofibrosis and contracture angle of the control group are significantly higher. Histologically, the apparent gap between patella and tibia, loose connective tissue, and much less density of the blood vessel are found in the ESWT group.Conclusions
ESWT could noninvasively, effectively, and safely prevent the formation of arthrofibrosis during the knee repair. 相似文献13.
14.
Ben A. Hickey Andrew Cleves Raza Alikhan Neil Pugh Len Nokes Anthony Perera 《Foot and Ankle Surgery》2019,25(1):59-62
Background
Our aim was to determine whether plasma levels of Tissue Factor (TF), Vascular Cell Adhesion Molecule 1 (VCAM-1), Interleukin 6 (IL-6) or D-dimer after foot and ankle injury could predict which patients would develop deep vein thrombosis (DVT).Methods
Patients aged 18–60 years with acute foot and ankle injury had venous blood sample to measure TF, VCAM-1, IL-6 and D-dimer within 3 days of injury. Patients had bilateral lower limb venous ultrasound to assess for DVT on discharge from clinic.Results
21 of 77 patients were found to have DVT (27%). There was no statistically significant association between levels of TF, VCAM-1, IL-6 or D-dimer and subsequent development of DVT.Conclusion
Tissue Factor (TF), Vascular Cell Adhesion Molecule-1 (VCAM-1), Interleukin-6 (IL-6) and D-dimer levels were not associated with development deep vein thrombosis in patients with acute foot and ankle injury. 相似文献15.
Nicola Krähenbühl Lena Siegler Manja Deforth Lukas Zwicky Beat Hintermann Markus Knupp 《Foot and Ankle Surgery》2019,25(2):143-149
Background
Although it has been proposed that in mid-stage ankle osteoarthritis, the subtalar joint can compensate for deformities above the ankle joint, the evidence is weak. We thus investigated subtalar joint alignment in different stages of ankle osteoarthritis using weightbearing computed tomography (CT) scans.Methods
The subtalar joint of 88 patients with osteoarthritis of the ankle joint and a control group of 27 healthy volunteers were assessed. Subgroups were performed according to the ankle deformity (varus and valgus) and stage of ankle joint osteoarthritis. Subtalar joint alignment was assessed on weightbearing CT scans.Results
A more valgus subtalar joint alignment was found in patients with varus ankle osteoarthritis. No significant difference of the subtalar joint alignment was evident when comparing different stages of ankle osteoarthritis.Conclusions
Varus ankles compensate in the subtalar joint for deformities above the ankle joint. Compensation does not correlate with the stage of ankle osteoarthritis. 相似文献16.
17.
Background and purpose
The treatment of paediatric distal radius diaphyseal metaphyseal junction (DRDMJ) fractures is a challenge. The purpose of this study was to introduce a new operative approach at the proximal “safe zone” of the posterior interosseous nerve (PIN) to treat paediatric DRDMJ fractures and analyse the safety and efficacy of antegrade elastic stable intramedullary nail (ESIN) fixation.Methods
Thirty paediatric patients with unstable and displaced DRDMJ fractures were treated by antegrade ESIN fixation from November 2015 to September 2017. We created the entrance site at the posterolateral side of the proximal radius and 2?4?cm distal to the articular surface of the radius, using the ESIN to immobilise the fractures. In the study, we reviewed patient demographics, complications, time until removal, and intraoperative time for hardware removal.Results
Complete fracture healing was achieved between 6 and 12 weeks after surgery. Except for 3 patients presenting with irritation of the skin, we did not observe any complications. Radiologically, no secondary displacement, nail migration, loss of fixation, consolidation delay, non-union, or refracture was noted.Conclusions
The antegrade ESIN fixation is a minimally invasive, easy-to-learn, alternative operative method to treat paediatric DRDMJ fractures.Level of evidence
Therapeutic Level IV. 相似文献18.
19.
Mattia Fortina Pietro Maniscalco Christian Carulli Luigi Meccariello Giovanni Battista Colasanti Serafino Carta 《Injury》2019,50(2):365-368
Introduction
Horse racing is a hazardous sport. We analyzed the incidence and characteristics of jockey injuries in a typical horse race.Methods
We analyzed all injuries sustained by 224 jockeys in the last 72 years.Results
It was found that in 96.1% of the races there was at least one fall and in 28.6% of the races 50% or more of the jockeys fell. In 43.4% of the falls, the jockey was taken to the emergency room. Comparing the Palio with traditional races in other countries, a higher injury incidence rate was observed for every 100 falls (109.884 vs 27–59) and a lower concussion rate/100 falls (0.97 vs 1.8-7.4).Conclusion
The Palio is one of the most threatening races that continues today. Jockeys are at greater risk for a fall than any other race in the world. 相似文献20.
V. Couteaux S. Si-Mohamed O. Nempont T. Lefevre A. Popoff G. Pizaine N. Villain I. Bloch A. Cotten L. Boussel 《Diagnostic and interventional imaging》2019,100(4):235-242