相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multiplex real-time quantitative polymerase chain reaction (mRT-qPCR) assay is commonly used to detect respiratory viruses, however, the sensitivity is limited for most reports. A panel of locked nucleic acid based multiplex closed one-tube nested real-time PCR (mOTNRT-PCR) assay consisting of five separate internally controlled RT-qPCR assays was developed for detection of 14 respiratory viruses. The sensitivity and reproducibility of mOTNRT-PCR panel were evaluated using plasmid standards and the specificity was evaluated using clinical samples. The clinical performance of mOTNRT-PCR panel was further evaluated with 468 samples collected from patients with an acute respiratory infection and compared with individual real-time PCR (RT-qPCR) assay. The analytical sensitivities of mOTNRT-PCR panel ranged from 2 to 20 copies/reaction, and no cross-reaction with common respiratory viruses was observed. The coefficients of variation of intra-assay and inter-assay were between 0.35% and 8.29%. Totally 35 clinical samples detected by mOTNRT-PCR assay panel were missed by RT-qPCR and confirmed true positive by sequencing of nested PCR products. The mOTNRT-PCR assay panel provides a more sensitive and high-throughput method for the detection of 14 respiratory viruses.  相似文献   

2.
A major drawback of mecA PCR to detect methicillin-resistant Staphylococcus aureus (MRSA) directly from patient materials is the high frequency of methicillin-resistant coagulase-negative staphylococci. Therefore, a reliable detection method for MRSA from clinical samples using real-time PCR was developed. The PCR assay targeting the integration site (orfX) of the staphylococcal cassette chromosome mec (SCCmec) was evaluated in MRSA SCCmec reference strains (n = 9), MRSA ST strains (n = 16) and clinical isolates of MRSA (n = 124), MSSA (n = 53), methicillin-resistant coagulase-negative staphylococci (n = 47), and methicillin-susceptible, coagulase-negative staphylococci (n = 32). The diagnostic values of the assay were 98% sensitivity and 100% specificity. Furthermore, the PCR detection method was evaluated with 60 swabs from different body sites which were incubated overnight in brain-heart infusion. The PCR gave positive results for 27 of 29 swabs which were found to contain MRSA by conventional methods. The diagnostic values of the PCR assay for these samples were 93% sensitivity and 100% specificity. To determine the in vitro sensitivity of the assay, swabs were inoculated with serially diluted bacterial suspensions. After overnight enrichment the detection limit of the PCR was less than 10 CFU/swab. This new real-time PCR assay proved to be a fast, sensitive and specific tool for MRSA detection in a routine microbiological laboratory.  相似文献   

3.
Several real-time PCR and nucleic acid sequence-based amplification (NASBA) primer pairs and a modified real-time PCR primer pair for the detection of enteroviruses were compared. The modified real-time PCR primer pair was evaluated on clinical samples in comparison with cell culture using the MagnaPure LC Isolation instrument for nucleic acid extraction. Six hundred forty samples could be examined both by cell culture and real-time PCR. Faecal specimens (n = 285), cerebrospinal fluid (n = 210), throat swabs (n = 113), biopsies (n = 1--, vesicular fluid (n = 11), and pleural fluid specimens (n = 9) were included. By culture, 26/640 (4%) samples were positive for enterovirus. By real-time PCR, the number of positive specimens was 50 (7.8%). Of the 210 cerebrospinal fluid samples, three were positive by culture and nine by real-time PCR. Seventeen and 33 of a total of 285 faecal specimens were positive by culture and real-time PCR, respectively. In case of discrepant results, the clinical symptoms were in accordance with an infection due to enteroviruses. Genotyping using the VP1 gene correlated with serotyping by neutralization. In contrast, six of the 19 specimens that could be typed both by neutralization and by sequencing using the VP4 domain yielded a different genotype, yet within the same species. Real-time PCR turned out to be suitable for the detection of enteroviruses in the daily routine setting. In comparison to rapid culture, it offers a rapid, more sensitive, and reliable assay; especially in cerebrospinal fluid, the yield of enteroviruses is much higher.  相似文献   

4.
A real-time, genus-specific 5' nuclease PCR assay for amplification of a 322-bp fragment of the per gene was developed for rapid (<2 h) identification of Brucella spp. from agar plates. The assay, including an internal amplification control (116 bp), identified Brucella strains (n = 23) and did not detect non-Brucella strains (n = 174), indicating its usefulness, particularly for laboratories with stringent quality assurance programs.  相似文献   

5.
A TaqMan based real-time PCR assay was developed for rapid detection and quantitation of herpes B virus (Cercopithecine herpesvirus 1) in clinical samples. The assay utilizes B virus-specific primers and a probe to the non-conserved region of the gG gene to discriminate B virus from closely related alphaherpesviruses. Fifty copies of B virus DNA could be detected with 100% sensitivity with a wide range of quantitation spanning 6 logs. The assay was highly reproducible with intra- and inter-assay coefficients of variation of 0.6 and 2.4%, respectively. Clinical utility of the developed real-time PCR was evaluated by testing genomic DNA prepared from B virus clinical isolates (n=23) and human and monkey clinical specimens (n=62). This novel method was also compared with conventional cell culture with respect to sensitivity and specificity. TaqMan PCR assay was shown to be equally specific and more sensitive than culture method (culture vs. PCR sensitivity 50%) and was able to identify all B virus clinical isolates tested. Fast, reliable assessment of B virus DNA in infected cells and tissues makes real-time PCR assay a valuable tool for diagnosis and management of B virus infections.  相似文献   

6.
In this study, real-time PCR with pathogen-specific molecular beacons (MB) and primers was evaluated for prediction of community-acquired pneumonia (CAP) causative agents, detecting six main CAP agents, Streptococcus pneumoniae, Haemophilus influenzae, Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, and Streptococcus pyogenes, simultaneously. The PCR assay was evaluated for fresh clinical specimens from infants and children (n = 389) and from adults (n = 40). The MB probes and primers are both pathogen specific, namely, the lytA gene for S. pneumoniae, the mip gene for L. pneumophila, and 16S rRNA genes for the remaining four organisms. DNA extraction of clinical specimens was performed with a commercially available EXTRAGEN II kit, and amplification was performed with Stratagene Mx3000P. The limit of detection for these pathogens ranged from 2 copies to 18 copies. The whole process from DNA extraction to the analysis was finished in less than 2 h. The obtained sensitivity and specificity of this real-time PCR study relative to those of conventional cultures were as follows: 96.2% and 93.2% for S. pneumoniae, 95.8% and 95.4% for H. influenzae, 100% and 100% for S. pyogenes, and 100% and 95.4% for M. pneumoniae, respectively. The sensitivity and specificity for M. pneumoniae relative to those of a serologic assay were 90.2% and 97.9%, respectively. In six clinical samples of C. pneumoniae, the real-time PCR gave positive predictable values, and in those cases, elevation of the titer value was also observed. In conclusion, we demonstrated that a real-time PCR assay with pathogen-specific MB is useful in identifying CAP causative agents rapidly and in examining the clinical course of empirical chemotherapy in a timely manner, supporting conventional culture methods.  相似文献   

7.
A screening method for methicillin-resistant Staphylococcus aureus (MRSA) by using selective broth and real-time PCR (broth-PCR) was developed and evaluated. The samples (n = 304) were cultured in the broth overnight, followed by nuc gene detection by real-time PCR. nuc-negative samples were further checked for the presence of nuc amplification inhibitors by a PCR internal inhibitor assay. nuc-positive samples and nuc-negative samples with PCR inhibitors were cultured onto plates and processed further. The diagnostic values for this MRSA screening method were 93.3% sensitivity, 89.6% specificity, 31.8% positive predictive value, and 99.6% negative predictive value. The application of the broth-PCR method will be able to report most of the negative samples (258 of 289 [89.3%]) on the next morning and can save as much as 84.9% (258 of 304) of the labor and cost spent on processing the nuc-negative specimens on plates. In the study, all the samples were processed in parallel by the broth enrichment method and the plating method for comparison. To identify MRSA, the isolated oxacillin-resistant S. aureus strains were tested by a duplex real-time PCR targeting the mecA gene and the nuc gene. A collection of MRSA, methicillin-susceptible Staphylococcus aureus, methicillin-resistant Staphylococcus epidermidis, and methicillin-susceptible Staphylococcus epidermidis strains and a panel of standard strains of 11 bacterial species other than S. aureus were also tested by this method, which was proved to be a valuable tool for MRSA identification in a routine microbiological laboratory.  相似文献   

8.
A real-time multiplex PCR using the orfX and staphylococcal cassette chromosome (SCC) mec of Staphylococcus aureus was developed. The aim was to achieve a rapid and sensitive high-throughput method for direct detection of heterogeneous methicillin-resistant S. aureus (MRSA) in clinical samples, present in a low-endemic population, such as in Sweden. Consecutive broth enriched pooled clinical screening samples (nares, throat and/or perineum/groin) (n = 541 pools), broth enriched clinical samples showing growth of methicillin-sensitive S. aureus (MSSA) (n = 95 pools), clinical MRSA isolates (n = 173), MRSA reference strains (n = 43) and various coagulase-negative staphylococcal isolates (n = 33) were analyzed. The multiplex PCR detected all heterogeneous MRSA strains (n = 173) obtained in our area as well as all pooled consecutive broth enriched clinical samples with MRSA, i. e. 36 of 541 pools. None of the CoNS were positive. However, 18 out of 541 pools (3.3%) were positive in the multiplex PCR but no growth of MRSA could be detected by subculture and were regarded as false positive. Furthermore, the assay is rapid and reliable negative results can be delivered to the clinician within 18 h that will facilitate the infection control management of patients and hospital staff.  相似文献   

9.
We compared the performance characteristics of a real-time PCR method, the LightCycler vanA/vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 microg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 microg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 microg/ml (n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 microg/ml (n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 microg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 microg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (approximately 3.5 versus > or =72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.  相似文献   

10.
11.
12.
13.
Chlamydia pneumoniae, an important respiratory pathogen, is difficult to culture, and detection rates by conventional PCRs vary considerably. A new quantitative ompA-based real-time PCR assay based on TaqMan technology for detection of C. pneumoniae in respiratory samples is described, and its performance in terms of sensitivity and reproducibility is compared with those of four published conventional PCRs (one single-step PCR targeting a cloned PstI fragment; two nested PCRs, one targeting the 16S rRNA gene followed by hybridization and the other targeting the ompA gene; and a touchdown enzyme time-release [TETR] PCR also targeting the 16S rRNA gene). Both ompA-based PCRs showed the best analytical sensitivity. All five assays could detect even lower target levels from spiked sputum, with the 16S rRNA assays performing better than the ompA-based nested PCR (10(-6) inclusion-forming units [IFU] were detected in four of four and two of four replicates by the 16S rRNA TETR PCR and the 16S rRNA nested PCR, respectively). In general, the ompA-based real-time protocol produced the most consistent positive results for all replicates tested down to 10(-6) IFU. Eight of 45 patient sputum specimens (18%) were C. pneumoniae DNA positive in at least one of four replicates tested by at least one assay. Without taking into consideration the analytical sensitivity or the reproducibility of the test results, the numbers of C. pneumoniae DNA-positive sputum specimens (n = 8) were four, three, two, two, and one for the 16S rRNA TETR assay, the PstI-based single-step PCR, the ompA-based real-time PCR, the ompA-based nested touchdown PCR, and the 16S rRNA-based nested PCR, respectively. However, the overall rate of concordance of positive results was low. Only one cell culture-positive sputum specimen was positive by four of five assays (14 of 16 replicates; mean cycle threshold value, 25; 10(8) particles/ml of sputum). Thirty-seven specimens were C. pneumoniae negative by all five assays for all replicates tested, as were all negative controls (n = 65 to 100 per testing panel). No PCR inhibitors were detected by real-time PCR or by the 16S rRNA-based nested assay. We confirm that the analytical sensitivity of an assay for the detection of C. pneumoniae does not necessarily predict its ability to detect its target in sputum. A quantitative, fast, and easy-to-handle diagnostic approach such as the ompA-based real-time TaqMan PCR described here might improve the detection of C. pneumoniae in respiratory samples.  相似文献   

14.
A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(?) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV detection in pigs in newly infected areas, control in endemic areas and surveillance in ASF-free areas.  相似文献   

15.
A TaqMan real-time PCR assay, the COBAS TaqMan human immunodeficiency virus (HIV) (HPS-CTMHIV) PCR assay, recently developed for the quantification of HIV type 1 RNA in plasma, was evaluated in comparison with the licensed COBAS AMPLICOR HIV-1 MONITOR (CAHIM) assay. In this study, we have analyzed the tests' sensitivities, precisions, and linearities using multiple replicates of a standard panel of HIV RNA covering a 7-logarithm range of concentrations, as well as serial threefold dilutions of high-titer clinical samples. The subtype inclusivity was also investigated, using a panel of subtypes A to H, while a collection of 160 clinical samples was analyzed to assess the tests' specificities and the systems' similarities. The results of these experiments showed that the HPS-CTMHIV assay has a sensitivity of 53 copies/ml (95% hit rate), 100% specificity, and good intra- and interassay precision. The results of the HPS-CTMHIV assay were linear in the 50- to 10(7)-copies/ml range, with a correlation coefficient (R) for expected versus observed results of 0.98. Compared to the CAHIM assay, the HPS-CTMHIV assay showed a high correlation (R=0.99) across the dynamic range of RNA concentrations that, for the CAHIM assay, requires two different sample preparations. Equivalent performances were also observed for the two systems in the detection and quantification of HIV subtypes A to H. These data indicate that the HPS-CTMHIV assay may be one of the tests of choice for monitoring viral load throughout the course of HIV infection and during highly active antiretroviral therapy.  相似文献   

16.
17.
Accurate quantification of hepatitis B virus (HBV) DNA levels is important for monitoring patients with chronic HBV infection and for assessing their responses to antiviral therapy. This study aimed to develop a real-time PCR assay that is sensitive and can accurately quantify a wide range of HBV DNA levels across the known HBV genotypes. An "in-house" real-time PCR assay using primers and a TaqMan probe in a highly conserved region of the HBV surface gene was designed. The assay was standardized against a WHO standard and validated against plasmids of HBV genotypes A through H. The linear quantification range was approximately 5 x 10(0) to 2.0 x 10(9) IU/ml. Results of samples from patients infected with HBV genotypes A through H tested using our real-time "in-house" PCR assay showed an excellent correlation with those of the Cobas Amplicor HBV Monitor (R2=0.9435) and the Cobas TaqMan HBV (R2=0.9873) tests. We have established a real-time PCR assay that is genotype independent and can accurately quantify a wide range of HBV DNA levels. Further studies of additional samples are ongoing to validate the genotype independence of our assay.  相似文献   

18.
Aspergillus fumigatus is an important cause of life-threatening invasive fungal disease in patients with compromised immune systems. Resistance to itraconazole in A. fumigatus is closely linked to amino acid substitutions in Cyp51A that replace Gly54. In an effort to develop a new class of molecular diagnostic assay that can rapidly assess drug resistance, a multiplexed assay was established. This assay uses molecular beacons corresponding to the wild-type cyp51A gene and seven mutant alleles encoding either Arg54, Lys54, Val54, Trp54, or Glu54. Molecular beacon structure design and real-time PCR conditions were optimized to increase the assay specificity. The multiplex assay was applied to the analysis of chromosomal DNA samples from a collection of 48 A. fumigatus clinical and laboratory-derived isolates, most with reduced susceptibility to itraconazole. The cyp51A allelic identities for codon 54 were established for all of the strains tested, and mutations altering Gly54 in 23 strains were revealed. These mutations included G(54)W (n = 1), G(54)E (n = 12), G(54)K (n = 3), G(54)R (n = 3), and G(54)V (n = 4). Molecular beacon assay results were confirmed by DNA sequencing. Multiplex real-time PCR with molecular beacons is a powerful technique for allele differentiation and analysis of resistance mutations that is dynamic and suitable for rapid high-throughput assessment of drug resistance.  相似文献   

19.
20.
A novel quantitative real-time PCR method using the duplex scorpion primer for detection of Chlamydia trachomatis DNA was developed and validated. The assay employs a duplex primer; its most important feature is the intramolecular probe-target interaction. The assay had many prominent characteristics. (i) The duplex probe is simpler to synthesize and significantly easier to purify than TaqMan probe because that the fluorescent dye pair and the quencher pair are in different oligonucleotides. (ii) The method has high sensitivity, specificity, intra- and interassay reproducibilities. (iii) The assay has a quantitative dynamic range of 25 to10(9) genome copies per reaction mixture. (iv) The scorpion system can identify 98.6% samples in the validation panel without retest. There were 81 positive samples and 67 negative samples, which were confirmed by two FDA-approved NAATs (the Roche Amplicor PCR assay, Abbott LCR kit) and our new method. Any two positive results out of the possible three-comparator results would define the infected-patient gold standard. Of the positive samples, 79 (97.5%) were found positive (ranging from 31 to 227,648 copies/microl, M=4219 copies/microl), whereas no negative samples were found positive by the assay. A quantitative, fast, and easy-to-handle diagnostic approach such as the MOMP-based real-time PCR described here might improve the detection of C. trachomatis infection.  相似文献   