首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
Condyle screws     
Uribe JS  Ramos-Zapata E  Vale FL 《Journal of neurosurgery. Spine》2011,14(1):139-40; author reply 140-1
  相似文献   

4.
Vaccaro AR 《Journal of neurosurgery. Spine》2011,15(4):359; discussion 360
  相似文献   

5.
目的比较椎间孔螺钉(paravertebral foramen screws,PVFS)、侧块螺钉(lateral mass screws,LMS)与椎弓根螺钉(pedicle screws,PS)的生物力学强度。方法选取8具新鲜冰冻尸体,男4具、女4具,死亡时年龄(45.3±11.2)岁。CT检查排除骨折、畸形、感染、肿瘤等疾病引起的骨质破坏或其他异常,最终筛选出30个C3~C6颈椎脊椎。将制备完成的颈椎节段标本顺序编号,应用随机数字表法将其随机分为三组,每组10个标本,分别用于双侧置入椎间孔螺钉(4.5 mm×12 mm螺钉)、侧块螺钉(3.5 mm×14 mm)与椎弓根螺钉(3.5 mm×24 mm螺钉)。随机选取一侧进行直接拔出力测试(速度5 mm/min),另一侧进行疲劳测试(位移±1.0 mm,频率1 Hz,循环500次)及残余拔出力测试。结果椎间孔螺钉的直接拔出力为(327.10±17.07)N,侧块螺钉为(305.71±11.63)N,椎弓根螺钉为(635.67±22.82)N。椎间孔螺钉的残余拔出力为(265.62±18.19)N,侧块螺钉为(192.80±17.10)N,椎弓根螺钉为(494.89±41.79)N。椎间孔螺钉、侧块螺钉和椎弓根螺钉的残余拔出力较直接拔出力均有不同程度降低(tPVFS=7.795,tLMS=17.267,tPS=9.349,P<0.001),分别下降了18.8%、36.93%和22.15%。椎弓根螺钉的直接拔出力高于椎间孔螺钉和侧块螺钉(t=34.245,t=40.741,P<0.001),椎间孔螺钉略高于侧块螺钉(t=3.275,P=0.004)。残余拔出力椎弓根螺钉最高,椎间孔螺钉次之,侧块螺钉最小(F=314.619,P<0.001)。椎间孔螺钉的首次循环载荷和首次达到设定位置时载荷均高于侧块螺钉(t=3.625,P=0.002;t=5.388,P<0.001)和椎弓根螺钉(t=2.575,P=0.019;t=2.680,P=0.015),侧块螺钉与椎弓根螺钉的差异无统计学意义(t=0.609,P=0.550;t=1.953,P=0.067)。椎间孔螺钉与椎弓根螺钉的末次循环载荷均高于侧块螺钉(t=5.341,P<0.001;t=3.439,P=0.003),但椎间孔螺钉与椎弓根螺钉的差异无统计学意义(t=1.606,P=0.126)。结论椎间孔螺钉的直接拔出力略高于侧块螺钉,残余拔出力明显高于侧块螺钉,抗疲劳性能与椎弓根螺钉相近并明显优于侧块螺钉,因此,颈椎椎间孔螺钉具有作为侧块螺钉和椎弓根螺钉有效替代的潜能。  相似文献   

6.
Traynelis VC 《Journal of neurosurgery. Spine》2012,16(3):236; discussion 236-236; discussion 237
  相似文献   

7.
Kepler CK  Vacaro AR 《Journal of neurosurgery. Spine》2011,15(2):144-5; discussion 145
  相似文献   

8.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

9.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

10.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

11.
目的 探讨在下颈椎经颈后正中入路应用经关节螺钉联合侧块螺钉或椎弓根螺钉行内固定治疗的固定效果.方法 2003年2月至2007年10月,对22例患者通过后路应用经关节螺钉联合侧块螺钉或椎弓根螺钉行内固定治疗,男14例,女8例;年龄24~73岁,平均43岁.其中下颈椎创伤性骨折脱位13例,颈椎后纵韧带骨化症4例,颈椎管狭窄伴Ⅱ型齿突骨折1例,颈椎间盘突出伴椎管狭窄4例.结果 共置入经关节螺钉45枚,其中C4,5 2枚,C5,639枚,C6,74枚;共置入侧块螺钉12枚,C3、C4各6枚;共置入椎弓根螺钉41枚,其中C24枚,C32枚,C46枚,C721枚,T18枚.术中所有螺钉均成功置入,未出现椎动脉、神经根和脊髓损伤等置钉相关并发症.22例患者均获随访,随访时间10个月~3年8个月,平均17个月.植骨融合时间3~5个月,平均3.5个月.术后发现1例患者的2枚经关节螺钉松动,部分脱出.经加强颈托制动,术后4个月获得融合.结论 通过后路固定下颈椎时,采用经关节螺钉联合侧块螺钉或椎弓根螺钉固定,均可取得较好的固定效果.  相似文献   

12.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

13.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

14.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

15.
两种长度的颈椎椎弓根螺钉与侧块螺钉拔出试验比较   总被引:9,自引:2,他引:7  
目的:比较两种长度的颈椎椎弓根螺钉和侧块螺钉的抗拔出力,探讨颈椎经椎弓根短螺钉固定的可行性。方法:5具C3~C5共15节新鲜颈椎标本,用长度为28mm和20mm的皮质骨螺钉分别置入椎弓根,并用20mm的螺钉行侧块双皮质固定,螺钉进入侧块深度约14mm。行拔出试验,比较螺钉的最大轴向拔出力。结果:椎弓根长螺钉的最大拔出力为650N,椎弓根短螺钉为585N,两者比较无显著性差异(P>0.01);侧块螺钉的最大拔出力为360N,与椎弓根短螺钉比较有显著性差异(P<0.0001)。结论:颈椎椎弓根短螺钉固定可提供足够的稳定性,其安全性相对较高。  相似文献   

16.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

17.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

18.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

19.
Objective To discuss the effect of transarticular screws combined with lateral mass screws or pedicle screws through posterior approach in the lower cervical spine. Methods From February 2003 to October 2007, 22 patients were treated using transarticular screws internal fixation combined with lateral mass screws or pedicle screws in Axis plating system and Vertex system. There were cervical fracture and dislocation in 13 patients, ossification of the posterior longitudinal ligament in 4, cervical canal stenosis associated with dentoid process fracture in 1, and cervical disc herniation associated with cervical stenosis in 4 patients. Lamina or facet bone grafting were used to achieve a long-term stability, with decompression and anterior approach or not. The starting point for screw insertion was located 1 mm medial to the midpoint of the lateral mass and the direction of the screw was 40° caudally in the sagittal plane and 20° laterally in the axial plane. Results All screws insertion was successful. A total of 45 transarticular screws were inserted, with 2 in C4,5, 39 in C5,6 and 4 in C6,7. A total of 12 lateral mass screws were inserted, with 6 in C3 and 6 in C4. A total of 41 pedicle screws were inserted, with 4 in C2, 2 in C3 and 6 in C4, 21 in C7 and 8 in T1. There was no complication related to screw insertion, such as injury to the vertebral artery, nerve roots or spine cord. The follow-up period ranged from 10 months to 3 years and 8 months (mean 17 months). All cases got bone fusion. Only one instance of screw partial backout was identified, but fusion was achieved in all pa-tients. In the follow-up period, only one instance of screw partial backout was identified, but fusion was achieved in all patients. Conclusion The combined use of transarticular screws and lateral mass screws or pedicle screws fixation in the lower cervical spine can enlarge the advantages of strong stability,relatively simple, and reduce operating risk when performed appropriately.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号