首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Intratendinous ganglion cyst is a very rare lesion with an unknown aetiology that originates within the tendon. We encountered a case of 43-year-old woman who complained of a palpable, non-tender mass in the thigh with increasing swelling. An intratendinous ganglion cyst in the semimembranosus tendon of the lower extremity was diagnosed and located by ultrasound and MRI. Nine months after a surgical excision, there were recurrent ganglion cysts along the semimembranosus tendon. We describe this case with a review of the relevant literature.A ganglion cyst is a common tumour-like lesion arising from various soft tissues that is generated by mucoid degeneration of the joint capsule, tendon or tendon sheath [1]. It can occur in any part of the extremities including the hand, wrist and foot. However, an intratendinous ganglion cyst is an uncommon lesion that originates within the tendon substance itself and causes soft-tissue swelling [2, 3]. As reported previously, intratendinous ganglion cysts are difficult to diagnose clinically before surgery and to excise completely [4]. For the most part, symptoms are mild in patients with pain and nerve compression [1, 5]. Ultrasound (US) and MRI can differentiate a ganglion cyst from other soft-tissue tumours and tumour-like lesions, and provide excellent information on the location of an intratendinous lesion [1, 2, 6]. To our knowledge, this is the first case report of an intratendinous ganglion cyst arising from the semimembranosus tendon itself.  相似文献   

2.

Objective

The aim of this study was to identify the risk factors associated with the prognosis of a subchondral insufficiency fracture of the femoral head (SIF).

Methods

Between June 2002 and July 2009, 25 patients diagnosed with SIF were included in this study. Sequential radiographs were evaluated for the progression of collapse. Clinical profiles, including age, body mass index, follow-up period and Singh’s index, were documented. The morphological characteristics of the low-intensity band on T1 weighted MRI were also examined with regards to four factors: band length, band thickness, the length of the weight-bearing portion and the band length ratio (defined as the proportion of the band length to the weight-bearing portion of the femoral head in the slice through the femoral head centre).

Results

Radiographically, a progression of collapse was observed in 15 of 25 (60.0%) patients. The band length in patients with progression of collapse [22.5 mm; 95% confidence interval (CI) 17.7, 27.3] was significantly larger than in patients without a progression of collapse (13.4 mm; 95% CI 7.6, 19.3; p<0.05). The band length ratio in patients with progression of collapse (59.8%; 95% CI 50.8, 68.9) was also significantly higher than in patients without a progression of collapse (40.9%; 95% CI 29.8, 52.0; p<0.05). No significant differences were present in the other values.

Conclusion

These results indicate that the band length and the band length ratio might be predictive for the progression of collapse in SIF.Subchondral insufficiency fractures of the femoral head (SIF) often occur in osteoporotic elderly patients [1-9]. Patients usually suffer from acute hip pain without any obvious antecedent trauma. Radiologically, a subchondral fracture is seen primarily in the superolateral portion of the femoral head [4,5,10]. T1 weighted MRI reveal a very low-intensity band in the subchondral area of the femoral head, which tends to be irregular, disconnected and convex to the articular surface [2,4,5,7,9,11]. This low-intensity band in SIF was histologically proven to correspond with the fracture line and associated repair tissue [5,9]. Some cases of SIF resolve after conservative treatment [5,11-14]; other cases progress until collapse, thereby requiring surgical treatment [4-10,15]. The prognosis of SIF patients remains unclear.The current study investigated the risk factors that influence the prognosis of SIF based on the progression to collapse.  相似文献   

3.

Objective

The aim of this study was to find out on an unselected patient group whether crossing vessels have an influence on the width of the renal pelvis and what independent predictors of these target variables exist.

Methods

In this cross-sectional study, 1072 patients with arterially contrasted CT scans were included. The 2132 kidneys were supplied by 2736 arteries.

Results

On the right side, there were 293 additional and accessory arteries in 286 patients, and on the left side there were 304 in 271 patients. 154 renal pelves were more than 15 mm wide. The greatest independent factor for hydronephrosis on one side was hydronephrosis on the contralateral side (p<0.0001 each). Independent predictors for the width of the renal pelvis on the right side were the width of the renal pelvis on the left, female gender, increasing age and height; for the left side, predictors were the width of the renal pelvis on the right, concrements, parapelvic cysts and great rotation of the upper pole of the kidney to dorsal. Crossing vessels had no influence on the development of hydronephrosis. Only anterior crossing vessels on the right side are associated with widening of the renal pelvis by 1 mm, without making it possible to identify the vessel as an independent factor in multivariate regression models.

Conclusion

The width of the renal pelvis on the contralateral side is the strongest independent predictor for hydronephrosis and the width of the renal pelvis. There is no link between crossing vessels and the width of the renal pelvis.Obstructions of the ureteropelvic junction (UPJ) can be caused by intrinsic or extrinsic factors [1]. Although there are no studies of this to date, crossing the UPJ by an aberrant crossing vessel is considered the most important [2] of the extrinsic factors [3]. Crossing vessels, which are thought to cause from 40% to over 50% of the extrinsic UPJ obstructions in adults [4, 5], are located ventral more often than dorsal to the UPJ. These are usually normal vessels of the lower pole segment [4, 69], which can be divided into additional renal arteries arising from the aorta, and accessoric renal arteries arising from branches of the aorta [10, 11]. The primary surgical therapy of choice is endoscopic endopyelotomy [12]. The success rate of 89–90% [12, 13] is thought to be noticeably poorer in patients with crossing vessels [12, 13]; however, this is not undisputed [14, 15]. Be that as it may, to prevent bleeding complications it is necessary to be familiar with the vascular situation around the UPJ prior to the procedure [3, 1618]. CT angiography is used for this purpose, as it is highly accurate, quick to perform and shows all relevant anatomical structures in relation to one another [3, 19, 20]. The objective of this study was to determine whether or not there are vascular morphological patterns or other factors that influence the width of the renal collecting system, regardless of the definitions of hydronephrosis.  相似文献   

4.
Intraductal papillary neoplasms of the breast form a wide spectrum of pathological changes with benign intraductal papilloma and papillary carcinoma. They can occur anywhere within the breast ductal system. This review illustrates some characteristic appearances of breast papillary neoplasms on coronal planes reconstructed by automatic breast volume scan. Such manifestations are not uncommon in papillary neoplasms, and familiarity will enable confident diagnosis.Papillary lesions of the breast are a heterogeneous group of breast lesions, including intraductal papilloma, atypical papilloma and intraductal papillary carcinoma [1,2]. Although the management of intraductal papillomas is varied, surgical excision is generally recommended as a precaution against the risk of a subsequent carcinoma [3,4]. Recently, some studies have suggested that patients with a tumour measuring <1.5 cm and an ultrasound Breast Imaging—Reporting and Data System (BI-RADS) category of 3 or 4a can be potentially selected for vacuum-assisted biopsy, but only if the tumour does not extend into the branching ducts [5,6]. Ueng et al [2] recommended that localised papillary lesions should be excised completely with a small rim of uninvolved breast tissue without any prior needle instrumentation if and when the papillary nature can be determined by imaging. Therefore, a careful imaging evaluation is necessary because it could help to identify the papillary neoplasm nature and select the high-risk lesions for proper treatment.Ultrasound has a greater sensitivity for detecting all papillary lesions than mammography [7]. Recently, automated breast ultrasound scanners have been developed, and the ultrasound volume data set of the whole breast can be acquired in a standard manner [8]. They have already shown potential for characterisation of breast tumours [9,10]. However, these studies did not detail the ultrasound features of intraductal papillary neoplasms on automated breast ultrasound. The reconstructed coronal views are also expected to provide more information and thus help to differentiate these lesions from other focal breast abnormalities.  相似文献   

5.

Objective

The aim of this study was to correlate the apparent diffusion coefficient (ADC) value of breast cancer with prognostic factors.

Methods

335 patients with invasive ductal carcinoma not otherwise specified (IDC NOS) and ductal carcinoma in situ (DCIS) who underwent breast MRI with diffusion-weighted imaging were included in this study. ADC of breast cancer was calculated using two b factors (0 and 1000 s mm–2). Mean ADCs of IDC NOS and DCIS were compared and evaluated. Among cases of IDC NOS, mean ADCs were compared with lymph node status, size and immunochemical prognostic factors using Student''s t-test. ADC was also correlated with histological grade using the Kruskal–Wallis test.

Results

Mean ADC of IDC NOS was significantly lower than that of DCIS (p<0.001). However, the mean ADC of histological grade of IDC NOS was not significantly different (p=0.564). Mean ADC of oestrogen receptor (ER)-positive or progesterone receptor (PR)-positive cancer was significantly lower than that of ER-negative or PR-negative cancer (p=0.003 vs p=0.032). Mean ADC of Ki-67 index-positive cancer was significantly lower than that of Ki-67 index-negative cancer (p=0.028). Mean ADC values of cancers with increased microvascular density (MVD) were significantly lower than those of cancer with no MVD increase (p=0.009). No correlations were observed between mean ADC value and human growth factor receptor 2 expression, tumour size and lymph node metastasis.

Conclusion

Low ADC value was correlated with positive expression of ER, PR, increased Ki-67 index, and increased MVD of breast cancer.Breast MRI is an established supplemental technique to mammography and ultrasonography for evaluation of suspicious breast lesions. Diffusion-weighted MRI (DWI) has recently been integrated into the standard breast MRI for discrimination of benign and malignant breast lesions obtained with dynamic contrast-enhanced MRI [1-13]. DWI is a non-invasive technique that represents the biological character of the mainly Brownian movement of protons in bulk water molecules in vivo. Apparent diffusion coefficient (ADC) values are quantified by measurement of mean diffusivity along three orthogonal directions, which are affected by cellularity of the tissue, fluid viscosity, membrane permeability and blood flow [7,9-11]. Microstructural characteristics, including water diffusion and blood microcirculations in capillary networks, were associated with ADC value. Decreased movement of molecules in highly cellular tissue showed correlation with a low ADC value [3,4]. Several studies of DWI of the breast have reported significantly lower ADC values in malignant tumours, compared with benign breast lesions and normal tissue [1-3,5-11,14]. Classic prognostic markers, including tumour size and grade, and lymph node status in patients with breast cancer, and molecular markers, including oestrogen receptor (ER), progesterone receptor (PR), Ki-67 index, human growth factor receptor 2 (HER2) protein and angiogenic molecular markers, have been reported [1,15,16]. Few studies have examined the correlation between ADC values and prognostic factors [1,8]. The purpose of this study is to compare ADC values of DWI of breast cancer with prognostic factors.  相似文献   

6.

Objectives

Despite many interventions that have been tried, controversy remains regarding the efficacy of interventions for contrast-induced nephropathy (CIN), so we aimed to evaluate the best evidence from recent meta-analyses.

Methods

We searched MEDLINE, EMBASE and the Cochrane library for interventions which have been used for CIN. We included only the most recent meta-analysis of each intervention. We extracted data on the methodology, quality and results of each meta-analysis. We performed narrative synthesis and adjusted indirect comparison of interventions that were shown to be statistically significant compared with a placebo.

Results

We included 7 systematic reviews and meta-analyses involving 9 different interventions for CIN, with a total of 15 976 participants. A significantly decreased risk of CIN was reported in meta-analysis of the following interventions: N-acetylcysteine [odds ratio (OR) 0.65, 95% confidence interval (CI) 0.48–0.88, I2=64%], theophylline [relative risk (RR) 0.48, 95% CI 0.26–0.89, I2=44%], statins (RR 0.51, 95% CI 0.34–0.77, I2=0%) and sodium bicarbonate (RR 0.62, 95% CI 0.45–0.86, I2=49%). Furosemide was shown to increase the risk of CIN (RR 3.27, 95% CI 1.48–7.26, I2=0%). Other interventions such as renal replacement therapy, angiotensin-converting enzyme inhibitors, dopamine and fenoldapam failed to show any significant difference from the control group.

Conclusion

Although there is some evidence to suggest that N-acetylcysteine, theophylline, sodium bicarbonate and statins may reduce incidence of CIN, limitations in the study quality and heterogeneity preclude any firm recommendations.

Advances in knowledge

N-acetylcysteine, theophylline, sodium bicarbonate and statins show some promise as potentially efficacious agents for preventing CIN, but more high-quality studies are needed before they can be recommended for use in routine practice.Contrast-induced nephropathy (CIN) is a well-recognised complication of contrast administration and the third leading cause of hospital-acquired acute kidney injury [1]. Despite some heterogeneity in definition, CIN is generally defined as an increase in serum creatinine over 25% or 44 μmol l−1 from baseline value 48–72 h after contrast media administration in the absence of any other aetiology [2]. CIN occurs in 0–10% of patients with normal renal function and in up to 25% of patients with pre-existing renal disease or certain risk factors such as diabetes, advanced age or nephrotoxic drugs [3]. A recent meta-analysis of 40 studies found that the pooled incidence of CIN was 6.4% after CT scanning [4].The pathophysiology of CIN is not completely understood but it is believed that contrast media causes vasoconstriction and renal medulla ischaemia, which leads to generation of free radicals and oxidative injury to tubular cells [5-8]. Studies have demonstrated that CIN is associated with increased in-hospital length of stay, morbidity and mortality and increased cost of medical care, especially in patients who require dialysis [9].A number of measures (hydration methods and physical agents) have been tried to prevent or treat contrast nephropathy. Hydration methods include N-acetylcysteine (NAC) and sodium bicarbonate. Studies have explored the value of NAC for contrast nephropathy and some have found that its use is associated with clinical benefits [10-13], but a recent large randomised trial found no such benefit associated with NAC use [14]. A number of published studies have suggested that bicarbonate is superior to saline in contrast-induced nephropathy [15-18]. However, there are also a number of unpublished studies which suggest no benefit associated with sodium bicarbonate use [19,20]. Theophylline and other drugs are methods that have been tried to reduce CIN. Theophylline has been shown to be protective in CIN in a few studies [21,22] but other studies have found no difference between theophylline and a control [23,24]. In addition, many drugs have been tried to prevent CIN [25-27].In response to the many studies, a number of meta-analyses have been published which have evaluated different measures used for CIN [28,29]. We reviewed the literature to identify these meta-analyses in order to determine the most up-to-date evidence on each intervention for CIN.  相似文献   

7.

Objective

The objective of this study was to demonstrate soft palate MRI at 1.5 and 3 T with high temporal resolution on clinical scanners.

Methods

Six volunteers were imaged while speaking, using both four real-time steady-state free-precession (SSFP) sequences at 3 T and four balanced SSFP (bSSFP) at 1.5 T. Temporal resolution was 9–20 frames s−1 (fps), spatial resolution 1.6×1.6×10.0–2.7×2.7×10.0 mm3. Simultaneous audio was recorded. Signal-to-noise ratio (SNR), palate thickness and image quality score (1–4, non-diagnostic–excellent) were evaluated.

Results

SNR was higher at 3 T than 1.5 T in the relaxed palate (nasal breathing position) and reduced in the elevated palate at 3 T, but not 1.5 T. Image quality was not significantly different between field strengths or sequences (p=NS). At 3 T, 40% acquisitions scored 2 and 56% scored 3. Most 1.5 T acquisitions scored 1 (19%) or 4 (46%). Image quality was more dependent on subject or field than sequence. SNR in static images was highest with 1.9×1.9×10.0 mm3 resolution (10 fps) and measured palate thickness was similar (p=NS) to that at the highest resolution (1.6×1.6×10.0 mm3). SNR in intensity–time plots through the soft palate was highest with 2.7×2.7×10.0 mm3 resolution (20 fps).

Conclusions

At 3 T, SSFP images are of a reliable quality, but 1.5 T bSSFP images are often better. For geometric measurements, temporal should be traded for spatial resolution (1.9×1.9×10.0 mm3, 10 fps). For assessment of motion, temporal should be prioritised over spatial resolution (2.7×2.7×10.0 mm3, 20 fps).

Advances in knowledge

Diagnostic quality real-time soft palate MRI is possible using clinical scanners and optimised protocols have been developed. 3 T SSFP imaging is reliable, but 1.5 T bSSFP often produces better images.Approximately 450 babies born in the UK every year have an orofacial cleft [1], the majority of which include the palate [2]. While a cleft palate is commonly repaired surgically at around 6 months [3], residual velopharyngeal insufficiencies require follow-up surgery in 15–50% of cases [4]. This residual defect results in an incomplete closure of the velopharyngeal port, which in turns leads to hypernasal speech. Assessment of velopharyngeal closure in speech therapy is commonly performed using X-ray videofluoroscopy or nasendoscopy [5,6]. While nasendoscopy is only minimally invasive, it may be uncomfortable and provides only an en face view of the velopharyngeal port. In contrast, X-ray videofluoroscopy is non-invasive and produces an image which is a projection of the target anatomy. Additional information may be obtained from projections at multiple angles [5,7], but anatomical structures may overlie each other. Furthermore, soft tissue contrast, such as that from the soft palate, is poor, although it may be improved using a barium contrast agent coating [8] at the expense of making the procedure more invasive and unpleasant. Arguably the greatest drawback of X-ray videofluoroscopy is the associated ionising radiation dose, which carries increased risk in paediatric patients [9].An increasing number of research studies have used MRI to image the soft palate [10-13] and upper vocal tract [14-17]. In contrast to X-ray videofluoroscopy and nasendoscopy, MRI provides tomographic images in any plane with flexible tissue contrast. As a result, MRI has been used to obtain images of the musculature of the palate at rest and during sustained phonation [10,18,19]. It has also been used to image the whole vocal tract at rest or during sustained phonation [20-27] and with a single mid-sagittal image dynamically during speech [13,15-17,28-35].For assessment of velopharyngeal closure, dynamic imaging with sufficient temporal resolution and simultaneous audio recording is required. Audio recording during imaging is complicated by the loud noise of the MRI scanner, and both the safety risk and image degradation caused by using an electronic microphone within the magnet. As a result, optical fibre-based equipment with noise cancellation algorithms must be used [36].In order to fully resolve soft palate motion, Narayanan et al [30] suggested that a minimum temporal resolution of 20 frames s−1 (fps) is required. A similar conclusion was reached by Bae et al [13], based on measurements of soft palate motion extracted from X-ray videofluoroscopy. Using segmented MRI, Inoue et al [35] demonstrated that changes in the velar position that were evident at acquired frame rates of 33 fps were not observed at 8 fps. However, MRI is traditionally seen as a slow imaging modality and achieving sufficient temporal resolution at an acceptable spatial resolution is challenging. Furthermore, as the soft palate is bordered on both sides by air, the associated changes in magnetic susceptibility at the interfaces make images prone to related artefacts.Dynamic MRI of the vocal tract has been performed using both segmented [17,33,37] and real-time acquisitions [13,15,16,28,31,38]. Segmented acquisitions [39] acquire only a fraction of the k-space data required for each image during one repetition of the test phrase and, hence, require multiple identical repetitions. While these segmented techniques permit high temporal and spatial resolutions [35], they require reproducible production of the same phrase up to 256 times [34], leading to subject fatigue. Differences between repeats of up to 95 ms in the onset of speech following a trigger have also been demonstrated [36].In contrast to segmented techniques, real-time dynamic methods permit imaging of natural speech, but require extremely rapid acquisition and often advanced reconstruction methods. The turbo spin echo (TSE) zoom technique [40] has been used to perform real-time MRI of the vocal tract [29,31] and is available as a clinical tool. The zoom technique excites a reduced field of view in the phase encode direction, hence allowing a smaller acquisition matrix and shorter scan for a constant spatial resolution. While such spin echo-based techniques are less susceptible to magnetic field inhomogeneity related signal dropout artefacts than other sequences, the frame rates achieved with these sequences are limited to 6 fps [31]. Gradient echo-based techniques have also been used to achieve similar temporal resolution [12,41,42] in the upper vocal tract, but are often used at much higher frame rates in other MRI applications such as cardiac imaging [43,44]. A number of gradient echo sequence variants exist. Fast low-angle shot (FLASH) type sequences [45] spoil any remaining transverse magnetisation at the end of every sequence repetition (TR). In contrast, steady-state free-precession (SSFP) sequences are not spoiled [46] and the remaining transverse magnetisation is used in the next TR to improve the signal-to-noise ratio (SNR), but renders the images sensitive to signal loss in the presence of motion. Balanced SSFP (bSSFP) sequences include additional gradients to bring the transverse magnetisation completely back into phase at the end of every TR [47,48]. The result is that bSSFP sequences have high SNR and are less sensitive to motion than SSFP sequences, but are more sensitive to field inhomogeneities, which cause bands of signal dropout.Both TSE and the gradient echo techniques discussed here sample in a rectilinear or Cartesian fashion, where one line of k-space is sampled in each echo. However, for real-time speech imaging, the highest acquired frame rates have been achieved by sampling k-space along a spiral trajectory [15,16,30,49]. While spiral imaging is an efficient way to sample k-space and is motion-resilient, it is prone to artefacts, particularly blurring caused by magnetic field inhomogeneities and off-resonance protons (i.e. fat) [50]. Recently, one group successfully used spiral imaging with multiple saturation bands and an alternating echo time (TE) to achieve an acquired real-time frame rate of 22 fps [13,16]. The saturation bands were used to allow a small field of view to be imaged without aliasing artefacts. The alternating TE was used to generate dynamic field maps which were incorporated into the reconstruction to compensate for magnetic field inhomogeneities. However, such advanced acquisition and reconstruction techniques are only available in a small number of research centres.The aim of this work is to optimise and demonstrate high-temporal-resolution real-time sequences available on routine clinical MRI scanners for assessment of soft palate motion and velopharyngeal closure. Consequently, radial and spiral acquisitions were excluded and the work focuses on Cartesian gradient echo sequences with parallel imaging techniques. As more clinical MRI departments now have 3 T scanners, imaging was performed at both 1.5 and 3 T to enable comparisons. At each field strength, we optimised sequences and implemented four combinations of spatial and temporal resolution in six subjects with simultaneous audio recordings.  相似文献   

8.
We used a retrospective non-randomised study to investigate the clinical effect of selective embolisation of the right gastric artery before hepatic arterial infusion chemotherapy (HAIC) using a port-catheter system. We evaluated whether the hepatic artery or the left gastric artery is the better approach for selecting the right gastric artery. A total of 367 patients (244 men and 123 women; mean age, 64.1 years) with unresectable advanced liver cancer underwent percutaneous implantation of a port-catheter system. In 294 of these patients, right gastric arterial embolisation with microcoils was attempted before placement of the port-catheter system to prevent gastric mucosal lesions. Approach was either through the hepatic artery (175 patients) or through the left gastric artery (119 patients), with success rates in catheterising the right gastric artery of 78.3% and 77.3%, respectively. If the attempt was unsuccessful, the catheter was redirected to the alternative approach, which increased the final success rate to 96.3%. Only seven patients experienced gastroduodenal mucosal lesions acutely after HAIC, as revealed by endoscopy. Embolisation of the right gastric artery is a feasible procedure that can reduce the incidence of gastric mucosal lesions associated with HAIC. Approach through either the hepatic artery or the left gastric artery is equally acceptable.Long-term hepatic arterial infusion chemotherapy (HAIC) via an implanted port-catheter system is a treatment option for patients with unresectable advanced liver cancer [1, 2]. In the past, such catheter placement was done by surgical laparotomy under general anaesthesia [36], an invasive procedure. However, recent advances in interventional techniques allow the implantation of port-catheter systems percutaneously under local anaesthesia [714].A frequent complication is reactive gastric or duodenal mucosal lesions, which result from chemical irritation caused by infusion of chemotherapeutic agents into adjacent organs through arteries originating from the common hepatic artery [1524]. One such complication is a gastric mucosal lesion caused by inflow of chemotherapeutic agents into the right gastric artery [1524]. To prevent this complication, the efficacy of selectively embolising the right gastric artery with coils at the time of implantation of the port-catheter system has been noted [21, 2527].In many cases, however, the right gastric artery is slender and angulated, with anatomical variations [26, 2831]. Hence, it is occasionally difficult to insert a catheter selectively into the right gastric artery by antegrade catheterisation via the site of the hepatic artery. This is the approach most commonly used by interventional radiologists. Failure to embolise the right gastric artery can result [26]. As an alternative method, a retrograde approach to the right gastric artery via the left gastric artery has been introduced [32, 33].Because HAIC with an implanted port-catheter system is performed in a relatively large number of cases in our institution, we have many opportunities to embolise the right gastric artery using both approaches. The aim of the present retrospective non-randomised study, which included a large number of subjects, was to evaluate the usefulness of right gastric arterial embolisation and to determine whether the antegrade or retrograde approach is more useful.  相似文献   

9.
Hydatid disease of the skull base is extremely rare, and intracranial extension of hydatid cysts through the skull base is even rarer. We report an interesting case of a 42-year-old man who presented with features of right vocal cord palsy. The diagnosis of hydatid cyst was made based on his history and on pre-operative MRI and was confirmed by surgery and histopathological examination.Hydatid disease is caused by infestation of the larval stage of tapeworm of the genus Echinococcus. Multiple echinococcal species produce hydatid disease, the most common causative species being Echinococcus granulosus. Echinococcus multilocularis is less commonly described but is more invasive, mimicking a malignancy [13]. Liver and lung involvement are most common, whereas bone and soft tissue involvement are rare [15]. Only a few cases of skull base involvement have been reported in the literature [4, 6, 7]. Our case is an unusual location of hydatidosis (i.e. hydatid disease of the skull base with intracranial extension). Usually, hydatid cyst of the head and neck region presents with local swelling and non-specific symptoms. Our patient presented with progressive hoarseness of voice. Compression of the vagus nerve by an intracranial or extracranial hydatid cyst is rare [4].  相似文献   

10.

Objective:

To describe the pattern and predictors of volumetric change of parotid glands during intensity modulated radiotherapy (IMRT) for oropharyngeal cancer.

Methods:

A cohort of patients undergoing weekly CT scans during dose-painted IMRT was considered. The parotid glands were contoured at the time of treatment planning (baseline) and on all subsequent scans. For a given patient, the parotid glands were labelled as higher (H) and lower (L), based on the mean dose at planning. The volume of each gland was determined for each scan and the percent change from baseline computed. Data were fit to both linear and quadratic functions. The role of selected covariates was assessed with both logistic regression and pair-wise comparison between the sides. The analyses were performed considering the whole treatment duration or each separate half.

Results:

85 patients, 170 glands and 565 scans were analysed. For all parotids except one, the quadratic function provided a better fit than the linear one. Moreover, according to both the logistic regression and pair-wise comparison, the cumulative mean dose of radiation is independently correlated with the parotid shrinkage during the first but not the second half of the treatment. Conversely, age and weight loss are predictors of relative parotid shrinkage during the entire course of the treatment.

Conclusion:

Parotid gland shrinkage during IMRT is not linear. Age, weight loss and radiation dose independently predict parotid shrinkage during a course of IMRT.

Advances in knowledge:

The present study adds to the pathophysiology of parotid shrinkage during radiotherapy.Fractionated radiotherapy is based on the assumption that the dose distribution obtained at planning is delivered during each treatment session. However, both set-up errors and tissue deformation can modify the dose that is administered. Shifts in the location of isodose levels compared with planning become critical for techniques that are highly conformal to the target(s), such as IMRT, justifying the interest in image guidance and adaptive radiotherapy [1]. Because of the sharp dose gradient around the target(s), subtle changes in the relative position or in the volume of organs at risk may alter the planned dose that the volume of an organ receives, as has been shown for the parotid glands [26].In a study by Ricchetti et al [7], we found that the parotid glands are the regions of interest that undergo the largest absolute and relative changes in volume during treatments. Although at least 16 articles have documented a significant percent reduction in the volume of the parotid gland during the course of fractionated radiotherapy [2,3,720], there are still several unanswered questions. It is unclear why some parotid glands shrink to about 50–60% during treatment, while others show only minimal changes. Studies that have investigated predictors of shrinkage have suggested weight loss during treatment, patient age and dose of radiation to the parotid as potential factors [2,9,1619]. However, results are inconsistent [3,8,10,14]. Some studies have suggested that dosimetrically spared parotid glands undergo only minimal volume changes during treatment [16,18], whereas others describe a similar behaviour regardless of the radiation dose [7,8,10]. Furthermore, it is unclear whether the daily percent volume change is constant [8,10,16,19] or variable [7,10,13] during the course of treatment. A variable daily percent change in the volume may indicate that there are predictive factors specific to certain portions of the fractionated radiation schedule. In the present article, we attempt to clarify these points.  相似文献   

11.
The classic imaging findings of posterior reversible encephalopathy syndrome (PRES) are of bilateral parietal and occipital subcortical vasogenic oedema, and are well established in the literature. As experience with PRES grows, varied and atypical presentations are being increasingly described. This pictorial review illustrates the variable presentations of PRES, including cases with atypical imaging findings. We illustrate cases of PRES with varying distributions of vasogenic oedema as well as cases with atypical imaging findings, such as variations of haemorrhage and restricted diffusion. Atypical imaging findings should not dissuade the diagnosis of PRES in the appropriate clinical situation, and knowledge of the varied appearance and atypical findings of PRES allows the radiologist to make this diagnosis.Posterior reversible encephalopathy syndrome (PRES) describes a neurological syndrome characterised by a variety of symptoms, including headache, altered mental status, visual disturbances and seizures, and is accompanied by a unique, potentially reversible imaging pattern [1,2]. Causes of PRES are diverse and include hypertension, eclampsia/pre-eclampsia, sepsis, immunosuppressive agents, chemotherapy, collagen vascular disease and renal failure [2]. Although the pathophysiology of PRES remains unknown, the currently preferred explanation relates to hypertension, impaired autoregulation and hyperperfusion [2]. The classic imaging findings are of vasogenic oedema in the subcortical white matter of the parietal and occipital lobes [3]. As experience with PRES grows in the literature, atypical presentations of PRES are being increasingly described. Authors have demonstrated cases of PRES with atypical vasogenic oedema patterns of distribution, such as frontal lobe, cerebellum, basal ganglia or brain stem involvement [3-6]. Unilateral cases of PRES have also been demonstrated [4]. In addition, cases of PRES with haemorrhage [7] and reversible restricted diffusion [8] have been described. Knowledge of the different presentations of PRES is important, as atypical imaging findings should not dissuade a diagnosis of PRES in the correct clinical context. The purpose of this review is to demonstrate the diverse imaging features of PRES. The cases illustrated in this review demonstrate clinical and imaging presentations characteristic of PRES, with the characteristic clinical and imaging reversibility associated with this diagnosis.  相似文献   

12.
The aim of this study was to determine the differences in CT findings of miliary tuberculosis in patients with and without HIV infection. Two radiologists reviewed retrospectively the CT findings of 15 HIV-seropositive and 14 HIV-seronegative patients with miliary tuberculosis. The decisions on the findings were reached by consensus. Statistical analysis was performed using the χ2 test, Mann–Whitney U-test and Fisher''s exact test. All of the HIV-seropositive and -seronegative patients had small nodules and micronodules distributed randomly throughout both lungs. HIV-seropositive patients had a higher prevalence of interlobular septal thickening (p = 0.017), necrotic lymph nodes (p = 0.005) and extrathoracic involvement (p = 0.040). The seropositive patients had a lower prevalence of large nodules (p = 0.031). In conclusion, recognition of the differences in the radiological findings between HIV-seropositive and -seronegative patients may help in the establishment of an earlier diagnosis of immune status in patients with miliary tuberculosis.Miliary tuberculosis (TB), which results from lympho-haematogenous dissemination of Mycobacterium tuberculosis, is a complication of both primary and post-primary TB [1, 2]. This disease results in the formation of small discrete foci of granulomatous tissue, which are uniformly distributed throughout the lung [3].An increase in TB incidence, including miliary TB, has been associated with infection by human immunodeficiency virus (HIV) [4]. In 2005, the World Health Organization estimated that 12% of HIV deaths globally were caused by TB, and that there were 630 000 new co-infections with TB and HIV [5]. Disseminated TB accounted for 5.4–8.1% of culture-confirmed TB cases, with 10–14% of patients coinfected with HIV having clinically recognisable dissemination [6, 7].Chest radiography may be helpful in the detection and final diagnosis of miliary TB. The characteristic radiographical findings consist of the presence of fine granular or numerous small nodular opacities measuring 1–3 mm in diameter scattered throughout both lungs [1, 3, 8, 9]. However, the radiograph may appear to be normal in the early stage of disease or in cases with nodules below the threshold of perceptibility; therefore, a diagnosis of miliary TB from chest radiographs can be difficult [10].Several studies have shown that CT imaging is more sensitive for the detection of parenchymal abnormalities in patients with AIDS who have active intrathoracic disease, and it has been suggested that CT may also be helpful in the differential diagnosis [1114]. In addition, it has been reported that certain imaging techniques provided by multidetector-row CT are useful for the diagnosis of multiple micronodular infiltrative lung disease [15]. CT findings of miliary TB have been described in previous reports [1618]; however, only a few studies on miliary TB in patients with HIV, particularly with reference to the CD4 count, have been reported [19, 20]. The radiographic manifestations of HIV-associated pulmonary TB are thought to be dependent upon the level of immunosuppression at the time of overt disease [2123].The purpose of this study was to determine the differences in the CT findings of miliary TB for patients with and without HIV infection and to analyse any correlation between the CT features and the level of immunosuppression in patients.  相似文献   

13.

Objective

To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens.

Methods

Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925).

Results

For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5).

Conclusion

In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100.There are currently three technologies widely available for diagnostic mammography: screen–film mammography (SFM) and two forms of large-field digital mammography [1]. The use of the term full-field digital mammography (FFDM) varies in the published literature and has been applied to both computed radiography (CR) and direct digital radiography (DR). Small-field digital mammography (SFDM) is mainly used for imaging during stereotactic biopsy [2].The advantages of digital mammography over SFM include: improved sensitivity in dense breast tissue, reduced radiation dose, the ability to manipulate images for review, and digital storage and retrieval methods [3]. CR was the earliest digital system in use. Imaging cassettes contain a re-useable photostimulable phosphor, replacing the traditional screen–film cassettes, and are then transferred to a laser reader. DR has an in-built detector and reader. Digital mammography has a lower spatial resolution than SFM, but has a very high contrast resolution. This allows the overall resolution of digital mammography to be at least equivalent to SFM [4-8], even when viewing calcification smaller than the pixel size [9]. Some CR systems have not met the quality standards of a number of governing bodies for mammography, including the European Network of Reference Assessment Centres (EUREF) and the NHS Breast Screening Programme (NHSBSP) [10,11]. This is related to the resolution achievable with 100 µm cassettes [12]. It is now known that CR systems using 50 µm cassettes can provide improved resolution, at an acceptable mean glandular dose, and have been approved for screening by the NHSBSP [13-15].Phantom studies indicate that the resolution and performance of DR are greater than those of CR [16,17], but have limitations. Although there are many clinical studies comparing the performance of DR and SFM [4-7,9,18-26], there are fewer that compare CR with SFM or DR [8,25,27-32]. We sought a method to compare the clinical diagnostic quality of two types of CR technology with that of SFM. We chose to study surgical specimens of breast tissue, which, although not absolutely comparable to in vivo mammography, allows realistic testing of image quality. In addition, multiple exposures can be obtained in reproducible conditions without irradiating the patient.  相似文献   

14.
We describe the case of a 32-year-old woman with pulmonary tuberculosis in whom a high-resolution CT scan demonstrated the reversed halo sign. The diagnosis of tuberculosis was made by lung biopsy and the detection of acid-fast bacilli in the sputum smear and culture. Follow-up assessment revealed a significant improvement in the lesions.The reversed halo sign is observed on high-resolution CT (HRCT) as a focal round area of ground-glass attenuation surrounded by a crescent or ring of consolidation [1, 2]. It was first described as being relatively specific for cryptogenic organising pneumonia [1], but was later observed in several other infectious [35] and non-infectious [6, 7] diseases.We report a case of a 32-year-old patient with tuberculosis who exhibited the reversed halo sign on chest CT. To our knowledge, this sign has not been previously described in an adult with pulmonary tuberculosis.  相似文献   

15.
Coronary angioplasties can be performed with either single-plane or biplane imaging techniques. The aim of this study was to determine whether biplane imaging, in comparison to single-plane imaging, reduces radiation dose and contrast load and shortens procedural time during (i) primary and elective coronary angioplasty procedures, (ii) angioplasty to the main vascular territories and (iii) procedures performed by operators with various levels of experience. This prospective observational study included a total of 504 primary and elective single-vessel coronary angioplasty procedures utilising either biplane or single-plane imaging. Radiographic and clinical parameters were collected from clinical reports and examination protocols. Radiation dose was measured by a dose–area–product (DAP) meter intrinsic to the angiography system. Our results showed that biplane imaging delivered a significantly greater radiation dose (181.4±121.0 Gycm2) than single-plane imaging (133.6±92.8 Gycm2, p<0.0001). The difference was independent of case type (primary or elective) (p = 0.862), vascular territory (p = 0.519) and operator experience (p = 0.903). No significant difference was found in contrast load between biplane (166.8±62.9 ml) and single-plane imaging (176.8±66.0 ml) (p = 0.302). This non-significant difference was independent of case type (p = 0.551), vascular territory (p = 0.308) and operator experience (p = 0.304). Procedures performed with biplane imaging were significantly longer (55.3±27.8 min) than those with single-plane (48.9±24.2 min, p = 0.010) and, similarly, were not dependent on case type (p = 0.226), vascular territory (p = 0.642) or operator experience (p = 0.094). Biplane imaging resulted in a greater radiation dose and a longer procedural time and delivered a non-significant reduction in contrast load than single-plane imaging. These findings did not support the commonly perceived advantages of using biplane imaging in single-vessel coronary interventional procedures.The use of biplane imaging during diagnostic coronary angiography and coronary interventions has been reported to reduce the total contrast load to the patient compared with single-plane imaging [18]. Additionally, acquiring two simultaneous images from two orthogonal planes has been reported to be more efficient than single-plane imaging [2, 811]. However, there are conflicting reports as to whether the radiation dose to the patient differs between biplane and single-plane imaging during coronary studies [3, 10, 11].Biplane imaging allows two cineangiography runs to be recorded simultaneously with a single injection of contrast. With single-plane imaging, however, the same information can be acquired only by carrying out the two cineangiography runs serially with two separate injections of contrast [1, 2, 8, 10]. Biplane imaging enables the operator to visualise the target lesion in orthogonal planes simultaneously and was presumed to be more efficient than single-plane imaging, particularly in difficult procedures [1, 4, 9, 12]. Accordingly, examinations would become faster, use of fluoroscopy would be reduced, fewer cineangiography runs would be required and the average radiation dose to the patient would be comparatively lower than in the case of procedures performed with single-plane imaging. The contrast load with biplane imaging was also expected to be significantly reduced [3, 4, 11].These perceived advantages of biplane imaging have led to recommendations for its use in paediatric and adult cardiac catheter laboratories [1, 4, 5, 10, 12, 13]. A previous study comparing biplane and single-plane imaging in 1156 diagnostic coronary angiography procedures found a small, but notable, reduction in contrast load accompanied by significantly longer table times and screening times with biplane imaging, although radiation dose was not examined [14].Contrast-induced nephropathy (CIN) is a complication associated with prolonged hospitalisation and development of end-stage renal failure [15]. Patients with pre-existing renal disease, diabetes, congestive heart failure or older age are at the greatest risk in developing CIN [1618]. These high-risk patients have a calculated incidence of CIN ranging from 10% to 30% [4, 1820]. Pre-hydration is the primary intervention for preventing contrast nephropathy [18], but is not possible in the setting of emergency (primary) angioplasty procedures. The total contrast load during interventional procedures has been established as an independent predictor of CIN and could be effectively controlled by the operator during primary angioplasty cases [18, 21, 22]. Biplane imaging is commonly employed to minimise the contrast load, especially in patients with renal impairment and those who require primary coronary angioplasty procedures [1, 6, 7, 18, 23].Numerous studies have found that the radiation dose varies significantly according to tube angulations, particularly in the combination of steep left anterior oblique (LAO) with cranial or caudal angulations [2427]. However, there are no published data on whether the radiation dose with biplane or single-plane imaging during coronary angioplasty differs between the three vascular territories: right coronary artery (RCA), left anterior descending (LAD) and left circumflex/intermediate (LCX). Furthermore, interventional cardiac procedures are operator dependent [2830]. Hence, it was postulated that senior cardiologists would be more familiar with biplane equipment and thereby more able to reduce radiation dose, contrast load and procedural time than less experienced operators. To our knowledge, no studies have been published that compare the impact of biplane and single-plane imaging in coronary angioplasty procedures.The aims of this study were to determine whether biplane imaging reduces both contrast load and radiation dosage and shortens procedural time in patients undergoing primary or elective coronary angioplasty compared with single-plane imaging. We also investigated if there was a significant difference in radiation dose, contrast load and procedural time between biplane and single-plane imaging during coronary angioplasty in the three main vascular territories (RCA, LAD and LCX) and in procedures performed by operators with various levels of experience.  相似文献   

16.

Objective

Primary lateral sclerosis (PLS) is a progressive degenerative disorder affecting upper motor neurons and requires a clinical diagnosis. Diffusion tensor imaging (DTI) is a quantitative method for assessing white matter fibre integrity. The purpose of the study was to evaluate the involvement of upper motor neurons by using DTI in PLS.

Methods

A patient with PLS was compared with eight age-matched controls. Differences in fractional anisotropy (FA) index were assessed using DTI on a voxel-by-voxel basis.

Results

Decreased FA was observed in the proximal part of the pyramidal tract bilaterally, which indicated degeneration of the pyramidal cells.

Conclusion

Voxel-based DTI could be used as an objective marker for detecting upper motor neuron degeneration in PLS.Primary lateral sclerosis (PLS) is an adult onset, non-hereditary degenerative disorder of the upper motor neuron related to a selective loss of precentral pyramidal neurons. Ιt is characterised by progressive spinobulbar spasticity owing to pyramidal tract degeneration, but preservation of the anterior horn motor neurons and no involvement of the lower motor neuron [14]. Currently there is no defining test or disease marker; thus, the diagnosis is usually made based on clinical presentation [1, 2].Diffusion tensor imaging (DTI) is an MRI technique that provides information about white matter fibre orientation and integrity in vivo based on the principles of free water molecules movement. Water molecules move in a random manner (isotropic diffusion); however, the presence of obstacles, such as axonal membranes and myelin sheaths, restrict the motion in a particular direction resulting in anisotropic diffusion. The fractional anisotropy (FA) index is a measure of the degree of directionality of diffusion [5, 6]. The assessment of FA has been used as a measure of white matter degeneration in many diseases as it can detect and quantify the degeneration of fibres along white matter tracts [5, 6]. The method that is usually used is the region of interest (ROI) approach [7]. Nowadays, an automated method of analysis is used for a voxel-wise comparison of DTI data throughout the whole brain [8, 9].In this report a single case of PLS was studied using DTI on a voxel-by-voxel comparison with a control group to detect upper motor neuron involvement.  相似文献   

17.
The aim of this study was to present the simplified rules of delineation of lymph node (LN) volumes in breast irradiation. Practical rules of delineation of LN areas were developed in the Department of Radiation Oncology of the Institut Curie. These practical guidelines of delineation were based on different specific publications in the field of breast and LN anatomy. The principal characteristic of these rules is their clearly established relationship with anatomical structure, which is easy to find on CT slices. The simplified rules of delineation have been published in pocket format as the illustrated atlas “Help of delineation for breast cancer treatment”. In this small pocket guide, delineation using the practical rules is illustrated, with examples from anatomical CT slices. It is shown that there is an improvement in delineation after the use of these simplified rules and the guide. In conclusion, this small guide is useful for improving everyday practice and decreasing the differences in target delineation for breast irradiation between institutions and observers.The value of lymph node irradiation has already been demonstrated by various studies and meta-analyses [13]. In the age of new conformal techniques, there is a real need for a clear definition of treated volumes, such as breast, tumour bed, lymph node areas and organs at risk (OAR) [410]. Many teams have been working for several years on the definition of treated volumes. Some delineation studies are exclusively theoretical and some provide a good anatomical atlas, but this information is difficult to use in everyday practice [415]. The treatment position has also been shown to be an important factor of variability in the depth and situation of lymph node volumes [5, 6]. Conformal and intensity-modulated radiotherapy (IMRT) require an exact definition of target volumes in terms of their anatomical limits for delineation on CT scans. Some authors have proposed anatomically based landmarks specific for breast cancer radiotherapy in order to delineate all regional lymph nodes and the breast [5, 6, 8, 10, 15, 16]. Despite this work, two recent papers have demonstrated the individual interobserver variability and differences in target and OAR delineation for breast irradiation, especially in lymph node areas [7, 8].This study was designed to propose a practical method to improve and facilitate the everyday delineation process for the clinicians of our department.  相似文献   

18.

Objectives

The purpose of this prospective study was to evaluate the accuracy of in-phase and out-of-phase imaging to assess hepatic iron concentration in patients with haematological malignancies and chronic liver disease.

Methods

MRI-based hepatic iron concentration (M-HIC, μmol g–1) was used as a reference standard. 42 patients suspected of having iron overload and 12 control subjects underwent 1.5 T in- and out-of-phase and M-HIC liver imaging. Two methods, semi-quantitative visual grading made by two independent readers and quantitative relative signal intensity (rSI) grading from the signal intensity differences of in-phase and out-of-phase images, were used. Statistical analyses were performed using the Spearman and Kruskal–Wallis tests, receiver operator curves and κ coefficients.

Results

The correlations between M-HIC and visual gradings of Reader 1 (r=0.9534, p<0.0001) and Reader 2 (r=0.9456, p<0.0001) were higher than the correlations of the rSI method (r=0.7719, p<0.0001). There was excellent agreement between the readers (weighted κ=0.9619). Both visual grading and rSI were similar in detecting liver iron overload: rSI had 84.85% sensitivity and 100% specificity; visual grading had 85% sensitivity and 100% specificity. The differences between the grades of visual grading were significant (p<0.0001) and the method was able to distinguish different degrees of iron overload at the threshold of 151 μmol g–1 with 100% positive predictive value and negative predictive value.

Conclusion

Detection and grading of liver iron can be performed reliably with in-phase and out-of-phase imaging. Liver fat is a potential pitfall, which limits the use of rSI.Iron overload is a clinically recognised condition with variety of aetiologies and clinical manifestations [1-4]. Liver iron concentration correlates closely with the total body iron stores [5]. The excess iron accumulates mainly in the liver and the progressive accumulation of toxic iron can lead to organ failure if untreated [2,4]. Several diseases causing iron overload, such as transfusion-dependent anaemia, haematological malignancies, thalassaemia, haemochromatosis and chronic liver disease, result in a large number of patients with a potentially treatable iron overload [1,2,4].Several quantitative MRI methods for iron overload measurement by multiple sequences have been established, such as proportional signal intensity (SI) methods and proton transverse relaxation rates (R2, R2*) [4,6,7]. A gradient echo liver-to-muscle SI-based algorithm [8] has been widely validated and used for quantitative liver iron measurement [8-11]. MRI-based hepatic iron concentration (M-HIC, μmol g–1 liver dry weight) with corresponding R2* [9] can be calculated with this method which is a directly proportional linear iron indicator, virtually independent of the fat fraction, as the echo times are taken in-phase [8,9]. This method showed a high accuracy in calibrations with the biochemical analysis of liver biopsies (3–375 μmol g–1) of 174 patients. The mean difference of 0.8 μmol g–1 (95% confidence interval of –6.3 to 7.9) between this method and the biochemical analysis is quite similar [8] to the intra-individual variability found in histological samples [12].The quantitative MRI methods are based on progressive SI decay, with the longer echo times due to relaxing properties of iron. Interestingly, this iron-induced effect is seen in MR images with multiple echoes [4,6-11], but also in dual-echo images, namely in-phase and out-of-phase imaging [13,14]. In-phase and out-of-phase imaging has become a routine part of liver MRI, performed initially for liver fat detection [6,13,15]. Quite recently some investigators have noticed an alternative approach of the sequence to detect liver iron overload due to the more pronounced SI decrease on in-phase images with the longer echo time [13,14]. Yet, to our knowledge, this is the first prospective study evaluating the accuracy of in-phase and out-of-phase imaging to assess hepatic iron concentration.The purpose of the study was to evaluate the capability and accuracy of dual-echo in-phase and out-of-phase imaging to assess hepatic iron concentration at 1.5 T in patients with haematological malignancies and chronic liver disease. MRI-based hepatic iron concentration (M-HIC, μmol g–1) was used as a reference standard [8,9].  相似文献   

19.
Ectopic pancreas is relatively uncommon and usually occurs in the stomach or duodenum. Retroperitoneal ectopic pancreas has not previously been documented. We report the case of a 48-year-old man with retroperitoneal ectopic pancreas that imitated bilateral adrenal tumours on ultrasound and MRI. Subsequent CT-guided biopsies confirmed an ectopic pancreas. The lesions remained stable during follow-up for 7 years. In retrospect, the similarity in signal intensities and enhancement pattern between the retroperitoneal masses and the pancreas may have been a clue to the diagnosis of this rare entity.Ectopic pancreas is an uncommon finding, with an estimated incidence of 0.55–13.7% according to autopsy analyses [1]. Most ectopic pancreatic lesions are found in the gastrointestinal tract and frequently involve the stomach (26–38% of cases), duodenum (28–36%), jejunum (16%) and, less commonly, Meckel''s diverticulum or the ileum [13]. Although rare, ectopic pancreas in the lung and the mediastinum has also been documented [4, 5]. However, ectopic pancreas in the retroperitoneum has not been reported. Herein, we describe the imaging features in a case of retroperitoneal ectopic pancreas with an extremely unusual presentation — imitation of bilateral adrenal tumours.  相似文献   

20.

Objectives

The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach.

Methods

The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set.

Results

The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach.

Conclusion

Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region.Ultrasound is frequently used to guide central venous cannulation [1] and peripheral nerve blocks [2,3]. However, published data suggest that it is rarely used for imaging the spine or for central neuraxial blocks (CNBs; epidural and spinal injections) [4], which is surprising considering that there are data suggesting that an ultrasound examination prior to epidural access (pre-puncture scan, preview scan or scout scan) improves technical [5-7] and clinical [7,8] outcomes and also the learning curve of obstetric epidural anaesthesia [9]. Despite these encouraging results, we believe that there are very few anaesthetists who currently perform a preview scan prior to epidural catheterisation [5,7] or real-time ultrasound-guided (USG) CNBs [6,10]. This is quite interesting considering that emergency physicians are able to interpret ultrasound images of the spine [11] and are performing lumbar puncture using ultrasound in the accident and emergency department [11,12]. Reasons for this paucity of data or a lack of interest in USG CNBs in regional anaesthesia are not clear, but the authors believe it may be due to a lack of understanding of spinal sonoanatomy. The aim of this study was to describe the sonoanatomy relevant for USG CNBs via the paramedian approach in the lumbar region.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号