Introduction

CT perfusion studies play an important role in the early detection as well as in therapy monitoring of vasospasm after subarachnoid hemorrhage. High-flow injections via central venous catheters are not recommended but may sometimes be the only possibility to obtain high-quality images.

Materials and methods

We retrospectively analyzed our data for CT perfusions performed with power injection of contrast material with an iodine concentration of 400 mg/ml via the distal 16G lumen of the Arrow three and five lumen central venous catheter with preset flow rates of 5 ml/s.

Results

104 examinations with central venous catheters were evaluated (67 with five lumen and 37 with three lumen). No complications were observed. Mean flow rates were 4.4 ± 0.5 ml/s using the three lumen catheter and 4.6 ± 0.6 ml/s using the five lumen catheter respectively. The mean injection pressure measured by the power injector was 200.7 ± 17.5 psi for the three lumen central venous catheter and 194.5 ± 6.5 psi for the five lumen catheter, respectively.

Conclusion

Following a strict safety protocol there were no complications associated with power injections of contrast material containing 400 mg iodine/ml with preset flow rates up to 5 ml/s via the distal 16G lumen of the Arrow multi-lumen central venous catheter. However, since power-injections are off-label use with Arrow central venous catheters, this procedure cannot be recommended until potential safety hazards have been ruled out by the manufacturer.  相似文献   

2.

Purpose

To evaluate failing hemodialysis fistula complications using 16-detector MDCTA, and to assess the accuracies of different 3D planes.

Materials and methods

Thirty patients (16 men, 14 women, aged 27–79 years) were referred for hemodialysis access dysfunction. Thirty-one MDCTA exams were done prior to fistulography. For MDCTA, contrast was administered (2 mL/kg at 5 mL/s) via a peripheral vein in the contralateral arm. Axial MIP, coronal MIP, and VRT images were constructed. Venous complications were evaluated on axial source images, on each 3D plane, and on all-planes together. Results were analyzed using McNemar test.

Results

Axial MIP, VRT and all-planes evaluations were most sensitive for fistula site detection (93%). Coronal MIP had the highest sensitivity, specificity and accuracy (35%, 96%, and 85%, respectively) for detecting venous stenosis. VRT and all-planes had the highest sensitivity and accuracy for detecting aneurysms (100%). All-planes and axial MIP were most sensitive for detecting venous occlusion (61% and 54%). Comparisons of detection frequencies for each venous pathology between the five categories of MDCTA revealed no significant differences (P > 0.05). MDCTA additionally showed 3 partially thrombosed aneurysms, 4 anastomosis site stenosis and 12 arterial complications.

Conclusion

MDCTA overall gives low sensitivity for detection of central vein stenosis and moderate sensitivity for occlusion. For most pathology, all-planes evaluation of MDCTA gives highest sensitivity and accuracy rates when compared to other planes. For venous stenosis and occlusion, MDCTA should be considered when ultrasonography and fistulography are inconclusive. MDCTA is helpful in identifying aneurysms, collaterals, partial venous thromboses and additional arterial, anastomosis site pathologies.  相似文献   

3.

Background

Management of congenital pulmonary vein stenosis is a diagnostic challenge. Echocardiography may be insufficient and thus cardiac catheterization remains the reference standard in this setting. The aim of the study was to investigate the accuracy of cardiac-non-gated CT using 64-slice technology in detecting congenital pulmonary vein stenosis in children.

Materials and methods

CT examinations were consecutively performed from May 2005 to December 2006 in 13 children aged 1.5–12 months (median 5 months) for suspected congenital pulmonary vein stenosis. Cardiac-non-gated CT acquisitions were performed after the peripheral injection of contrast agent. Pulmonary veins were evaluated for their pattern of connectivity from the lung to the left atrium and for the presence of stenosis. CT findings of pulmonary vein stenosis were compared with combined findings available from echocardiography, catheterization and surgery.

Results

Pulmonary veins from the right lung (n = 29) and left lung (n = 26) were evaluated as separate structures (N = 55). Of the 55 structures, 32 had surgical and/or catheterization data and 45 had echocardiography for comparison. CT visualized 100% (55/55) of the investigated structures, while echocardiography visualized 82% (45/55). In the 13 subjects CT identified 10 stenotic pulmonary veins. CT confirmed the echocardiography suspicion of pulmonary vein stenosis in 100% (7/7) and established a new diagnosis in 3 other patients. CT agreed with surgery/catheterization in 100% (10/10) of the available comparisons.

Conclusion

Cardiac-non-gated CT assessed the pulmonary veins more completely than echocardiography and should be considered as a viable alternative for invasive pulmonary venography for detecting pulmonary vein stenosis in children.  相似文献   

4.

Objective

Comparison of arterial and venous coronary artery bypass flow measurements using 3-T magnetic resonance (MR) phase contrast in correlation with intraoperative Doppler flow measurements.

Methods

Fifty-six coronary bypasses (right coronary artery n = 18, left internal mammary artery to left anterior descending artery n = 16, marginal artery n = 7, circumflex artery n = 7, diagonal artery n = 6, left anterior descending artery n = 1, and right internal mammary artery to right coronary artery n = 1) were studied in 27 asymptomatic patients. In this prospective study, each bypass was studied intra-operatively using Doppler flow measurement. Within one week post surgery, patients were studied using a 3-T MR scanner (Magnetom Verio, Siemens, Erlangen, Germany) using velocity encoded phase-contrast flow measurements.

Results

Intraoperative Doppler flow measurements demonstrated regular flow patterns in all vascular territories supplied. All bypasses were patent on MRI and flow measurement results were as follows: median flow 60 ml/min (interquartile range (IQR): 37.5–78.5 ml/min). For comparison, the corresponding median intraoperative flow was 58 ml/min (IQR: 41–80 ml/min) (p < 0.001; R = 0.44). Linear regression analysis demonstrated a significant correlation for venous bypasses (p = 0.0002; R = 0.48), but not for arterial bypasses (p = 0.09; R = 0.24).

Conclusion

This study demonstrated that MR flow measurements of venous bypass grafts agreed more with Doppler than arterial bypass grafts. However, bypass patency was confirmed for all patients. In the future, this technique may be used for non invasive coronary bypass graft follow-up.  相似文献   

5.

Purpose

The passive reflux into ovarian veins (OVs) is well known as a common finding in normal asymptomatic women. The purpose of this study was to investigate the hemodynamics of OVs in women with myomatous uterus.

Materials and methods

Thirty-two women with symptomatic uterine leiomyomata underwent time-of-flight MR (TOF-MR) angiography, including venography and arteriography, and contrast-enhanced MRI. The frequency of reflux into OVs on TOF-MR angiography was retrospectively assessed with uterine volume, and compared to that of normal women in previous publication. The statistical evaluation was performed using Fisher's exact test.

Results

The mean uterine volume was 932 ± 612 ml (range, 301–2627 ml). The reflux into left OVs was observed in 4 of 32 women (13%) and that into right OVs was noted in 0 of 32 women (0%). These rates were significantly lower than those of normal asyptomatic women in the previous publication (p < 0.05). The reflux into OVs was observed in 0 of 19 women (0%) with 600 ml or larger myomatous uterus, whereas it was noted in 4 of the remaining 13 women (31%) with less than 600 ml myomatous uterus, with significant difference between the two groups (p = 0.02).

Conclusions

We found that reflux into OVs was infrequent in the vast majority of women with myomatous uterus, especially those with larger uterus due to leiomyomata on the basis of TOF-MR angiography. These findings suggested myomatous uterus could affect the flow direction of OVs, and passive reflux into OVs might be prevented due to the influence of antegrade flow of OVs.  相似文献   

6.

Objective

To prospectively evaluate the accuracy of left and right ventricular function and myocardial mass measurements based on a dual-step, low radiation dose protocol with prospectively ECG-triggered 2nd generation dual-source CT (DSCT), using cardiac MRI (cMRI) as the reference standard.

Materials and methods

Twenty patients underwent 1.5 T cMRI and prospectively ECG-triggered dual-step pulsing cardiac DSCT. This image acquisition mode performs low-radiation (20% tube current) imaging over the majority of the cardiac cycle and applies full radiation only during a single adjustable phase. Full-radiation-phase images were used to assess cardiac morphology, while low-radiation-phase images were used to measure left and right ventricular function and mass. Quantitative CT measurements based on contiguous multiphase short-axis reconstructions from the axial CT data were compared with short-axis SSFP cardiac cine MRI. Contours were manually traced around the ventricular borders for calculation of left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and myocardial mass for both modalities. Statistical methods included independent t-tests, the Mann–Whitney U test, Pearson correlation statistics, and Bland–Altman analysis.

Results

All CT measurements of left and right ventricular function and mass correlated well with those from cMRI: for left/right end-diastolic volume r = 0.885/0.801, left/right end-systolic volume r = 0.947/0.879, left/right stroke volume r = 0.620/0.697, left/right ejection fraction r = 0.869/0.751, and left/right myocardial mass r = 0.959/0.702. Mean radiation dose was 6.2 ± 1.8 mSv.

Conclusions

Prospectively ECG-triggered, dual-step pulsing cardiac DSCT accurately quantifies left and right ventricular function and myocardial mass in comparison with cMRI with substantially lower radiation exposure than reported for traditional retrospective ECG-gating.  相似文献   

7.

Objectives

To investigate the relationship between cardiac output, end diastolic volume and the contrast enhancement in coronary CT angiography using 320-detector CT.

Materials and methods

A total of 38 patients underwent coronary CT angiography by using a 320-detector CT scanner (detector configuration, 320 × 0.5 mm). The attenuation value of the ascending aorta at the level of the orifice of the left main trunk was measured. The cardiac output (CO), end diastolic volume (EDV) and stroke volume (SV) were measured by echocardiography. The EDV was normalized to the body surface area (BSA). The total blood volume injected from the left ventricle from the beginning of the contrast agent injection to the time of image acquisition was determined to be the total injected blood volume (TIV), which is a product of SV and the number of heart beats from the initiation of contrast agent injection to the scan.

Results

There was a negative correlation between the attenuation of the ascending aorta and CO (r = −0.44, P = 0.0053). However, the negative correlation between the attenuation of the ascending aorta and TIV was stronger (r = −0.52, P = 0.0007). There was a negative correlation between the attenuation of the ascending aorta and EDV/BSA (r = −0.45, P = 0.0039).

Conclusion

In 320-detector CT, contrast enhancement in CCTA with a lesser amount of contrast medium decreases when cardiac output is high. Patients with larger EDV/BSA may also show decreased attenuation.  相似文献   

8.

Purpose

To evaluate the efficacy of the dual-source parallel radiofrequency system (DS system) for gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (Gd-EOB-MRI).

Materials and methods

Twenty-six subjects with liver diseases underwent hepatobiliary phase imaging of Gd-EOB-MRI using either the DS system or a single-source radiofrequency system with or without body-tuned CLEAR, which is a post-processing correction method of B1 inhomogeneity-induced signal loss (SSBTC+ and SSBTC−, respectively). The left and right lobes of the liver were separately assessed. Qualitatively, the homogeneity of signal intensity distribution was scored using a 3-point scale. Quantitatively, lesion-to-liver and spleen-to-liver contrast ratios (CRs) were calculated. The scores and CRs were compared among the three techniques by two-way analysis of variance and Tukey's Honestly Significant Difference post hoc test. Values of p < 0.05 were considered statistically significant for each analysis.

Results

The DS system showed a significantly better score in the left lobe of the liver, and higher lesion-to-liver and spleen-to-liver CRs in the left and right lobes of the liver, compared with SSBTC+ or SSBTC− (p < 0.05). The DS system and SSBTC− showed no significant differences in scores in the right lobe of the liver but they showed significantly better scores than SSBTC+ (p < 0.05).

Conclusion

The DS system is more advantageous to improve the homogeneity of signal intensity distribution and tissue contrast of Gd-EOB-MRI than the post-processing correction method independently of the site.  相似文献   

9.

Objective

To prospectively evaluate the clinical benefit of a central venous port system, which is approved for contrast media injection during contrast enhanced computed tomography.

Materials and methods

At a university teaching hospital, 98 patients (59 female, 39 male; median age 61.7 years; range 23–83) had a power-injectable central venous port catheter system implanted. All implantations were performed under ultrasonographic and fluoroscopic guidance by interventional radiologists. Procedure related immediate (up to 24 h after implantation), early (<30 days after implantation) and late complications were documented. The frequency of port system use for contrast enhanced computed tomography scans was also considered. Any port capsule migration was assessed indirectly by determining the catheter tip position. The intended follow-up period was 180 days.

Results

An overall complication rate of 0.69 for 1,000 catheter days in 78 evaluated ports was recorded (12 ports affected, 15.4%). During the observational period, 40 of 104 contrast enhanced computed tomography scans were performed utilizing the port for contrast media administration (38.5%). 30 catheter tip retractions of more than 3 cm were observed in 82 patients (36.6%). Overall, tip dislocations were statistically more frequent in the female subgroup.

Conclusion

The complication rate found in this study is comparable to those, which have been published for standard port systems. The utilization of the device for contrast media injection during contrast enhanced computed tomography scans should be increased. Finally, the port capsule has to be carefully positioned and fixed to prevent migration.  相似文献   

10.

Aim

To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT).

Materials and methods

A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22–67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified (<60, 61–70, 71–80 and >81 kg).

Results

Aortic attenuation was significantly superior (p < 0.05) in the dose adjusted by weight group than in the fixed dose group. Patients who weighed >61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p < 0.01). In dose-adjusted group, there was a savings of €4.1 per patient in patients weighing <80 kg. In patients weighing >80 kg, there was an over cost of €10.7 per patient.

Conclusions

An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of €1.34 per patient.  相似文献   

11.

Objectives

Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease.

Methods

We retrospectively compared autopsy and CT findings of 30 cases with significant (≥75%), insignificant (<75%), or absent coronary artery stenosis to post-mortem cardiac MR findings. The chi-square test was used to investigate if the occurrence of CSA depends on the presence or absence of stenosis. Sensitivity, specificity and predictive values were calculated for each finding.

Results

CSA indicates the absence of (significant) stenosis (p < 0.001). The occurrence of paired dark bands in lieu of CSA on post-mortem cardiac MR suggests (significant) coronary arteries stenosis (p < 0.001). Both findings have a high specificity but low sensitivity.

Conclusions

CSA is a marker of vessel patency. The presence of paired dark bands indicates stenosis. These criteria improve the ability of minimally invasive or virtual autopsy to detect coronary artery disease related deaths.  相似文献   

12.

Purpose

To compare test bolus and bolus tracking for the determination of scan delay of high-pitch dual-source CT pulmonary angiography in patients with suspected pulmonary embolism using 50 ml of contrast material.

Materials and methods

Data of 80 consecutive patients referred for CT pulmonary angiography were evaluated. All scans were performed on a 128-channel dual-source CT scanner with a high-pitch protocol (pitch 3.0, 100 kV, 180 mA s). Contrast enhancement was achieved by injecting 50 ml of iomeprol followed by a saline chaser of 50 ml injected at a rate of 4 ml/s. The scan delay was determined using either the test bolus (n = 40) or bolus tracking (n = 40) technique. Test bolus required another 15 ml CM to determine time to peak enhancement of the contrast bolus within the pulmonary trunk. Attenuation profiles in the pulmonary trunk and on segmental level as well as in the ascending aorta were measured to evaluate the timing techniques. Additionally, overall image quality was evaluated.

Results

In all patients an adequate and homogeneous contrast enhancement of more than 250 HU was achieved in the pulmonary arteries. No statistically significant difference between test bolus and bolus tracking was found regarding attenuation of the pulmonary arteries or overall image quality. However, using bolus tracking 15 ml CM less was injected.

Conclusion

A homogeneous opacification of the pulmonary arteries and sufficient image quality can be achieved with both the bolus tracking and test bolus techniques with significant lower contrast doses compared to conventional contrast material injection protocols.  相似文献   

13.

Objective

To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA).

Methods

An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg/ml), 0.5 ml Lidocaine® (5 mg/ml) and 0.15 ml gadolinium (Omniscan 0.5 mmol/ml). The drug solution was placed in the central proximal part of the wrist between the distal radius and the lunate bone. Coronal and axial MRI sequences were performed after the injection to visualize the distribution. Carpal distribution (radio-carpal, inter-carpal, and carpo-metacarpal) as well as radio-ulnar distribution was recorded. Full distribution in one compartment was given the value 1, partial distribution 0.5 and no distribution 0. A sum of the total distribution for all four compartments was calculated and correlated to the clinical parameters and the MRI OMERACT scores.

Results

No uniform pattern was seen in the distribution of the contrast. Only two patients had full contrast distribution to all four compartments, and the mean distribution count for all patients was 2.4 (range 0.5–4). The distribution count correlated with the MRI OMERACT synovitis score (r = 0.60, p = 0.014), but not with the erosions, bonemarrow oedema scores or any clinical parameters.

Conclusion

The distribution of contrast on MRI showed patient specific and random patterns after IA injections in active RA wrist joints. The degree of distribution increased with the MRI synovitis score, while no association was found with the erosion- and bonemarrow oedema score. These results indicate that a single injection into a standard injection site in the proximal part of the wrist cannot be assumed to distribute – and treat – the whole joint.  相似文献   

14.

Purpose

The objective of this study was to describe contrast-enhanced magnetic resonance angiography (MRA) of the lower extremities at 3.0 T system for assessment of high resolution images in patients with peripheral arterial occlusive disease (PAOD).

Material and methods

21 Patients with suspected PAOD were examined with four-station MRA at a 3.0 T MR system. The MRA protocol consisted of a hybrid technique with two contrast media injections, the first one for visualization of the calf and foot vasculature (non-moving-table technique), the second one for imaging the aortoiliacal and femoral arteries (moving-table technique). For the femoropopliteal and calf station a randomly segmented central k-space ordering (contrast-enhanced timing-robust angiography [CENTRA]) was used. MR-images were analyzed independently by two radiologists with regard to image quality, venous overlap and grade of stenosis. In 6 patients digital subtraction angiography was performed within the following 7 days and evaluated by two radiologists in consensus with regard to the grade of stenosis. The vasculature-tree of each leg was divided in 12 segments, and 3 anatomical regions (iliacal, femoropopliteal, calf/foot).

Results

490 and 488 of 495 arterial segments were visualized with diagnostic image quality by observer 1 and observer 2, respectively. Image quality was excellent in 470 and 457 arterial segments, respectively. Only 4 segments were rendered as non-diagnostic due to venous overlap. Relevant arterial stenoses (50–99%) were detected in 43 and 47 segments by observer 1 and observer 2, 66 and 65 arterial segments, respectively, were interpreted as occluded.

Conclusion

The hybrid MRA protocol at 3.0 T offers high diagnostic quality for the whole peripheral arterial tree without venous contamination at high spatial resolution.  相似文献   

15.

Objectives

This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA).

Materials and methods

IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET.

Results

With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%).

Conclusion

Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.  相似文献   

16.

Purpose

To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT.

Material and methods

140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3 mg/s) and total iodine load (44.4 g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated.

Results

Arterial contrast enhancement was significantly higher for the 300 mg/ml contrast medium compared to 370 mg I/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P < 0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P < 0.001). No differences in tracer uptake were found between the contrast media (all P > 0.05). Visual assessment revealed no relevant differences between the different PET reconstructions.

Conclusions

There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol.  相似文献   

17.

Purpose

To clarify the optimal iodine dose of contrast material for 3-dimensional multidetector-row CT angiography (3D-MDCTA) of the venous vasculature of the liver using volume rendering technique.

Materials and methods

This study included 103 patients who were randomly assigned to 5 contrast-enhanced MDCT protocol groups with different body-weight-tailored doses of contrast material: 500, 600, 630, 650, and 700 mgI/kg body weight. The arterial, portal, and hepatic parenchymal phases were obtained to evaluate enhancement values of the aorta, portal vein, and hepatic vein. Visualization of the portal and hepatic veins on the volume-rendering images of 3D-MDCTA was evaluated using a 5-point grade. Dunnett's test was used to compare the mean enhancement value and mean grades of image quality (700 mgI/kg dose group was control).

Results

The mean enhancement values of portal and hepatic vein in the group with 500 and 600 mgI/kg were significantly lower than those of the control group. During visual assessment, a significantly lower mean grades were observed in 500 mgI/kg groups for the portal vein, and 500 and 600 mgI/kg groups for hepatic vein. There were no significant intergroup differences in mean enhancement values and visual assessment among the groups using 630 mgI/kg or more.

Conclusion

Iodine doses of 630 mgI/kg was recommended for 3D-MDCTA.  相似文献   

18.

Purpose

Quantification of vascular endothelial cell damage induced by iodinated contrast media using an in situ perfused rat vena cava model.

Materials and methods

The institutional review board approved this study protocol prior to the commencement of all studies. A laparotomy was performed in 90 rats divided into 18 groups of five, and an 18G-catheter was inserted into the abdominal vena cava (mean length: ca 8 mm). After sacrificing, a thoracotomy was done and the outflow perfusate was emitted via a polyethylene tube inserted into the thoracic vena cava through the right atrium for an open system. Iopamidol (300 or 370 mg I/mL, 50 or 100 mL) was injected via the abdominal vena cava at a rate of 1, 4, or 8 mL/s. The abdominal vena cava was removed for histological analysis (n = 5). Physiological saline was injected as a negative control. The detachment percentage of endothelial cells was calculated by measuring the circumference and detachment section of the endothelium. The difference of the detachment percentage and circumference between each group was compared with Tukey's range test.

Results

In contrast media groups, the severity of damage to the vascular endothelial cell was direct proportional to the increase of injection rate. The detachment percentage at 4 or 8 mL/s was significantly higher than that at 1 mL/s. As a result, the correlation between the injection rate and severity of cell damage was significant; however, the detachment percentage among contrast media groups was not significant at any injection rate.

Conclusion

The in situ vena cava model was able to quantify contrast media injection related endothelial damage based on histopathological endpoints. Moreover, our results indicate that mechanical shear stress besides physico-chemical properties such as osmolality or viscosity cause endothelial damage.  相似文献   

19.

Objectives

To compare estimated remnant liver volume (ERLV) ratios among the major main portal vein (MPV) variants.

Methods

Eighty-five potential donors underwent multidetector CT examination. Arterial, portal and hepatic venous phase images were obtained. CT volumetric measurements were performed by using summation-of-area method. MPV variants were classified into three groups. In type 1 (group 1), the MPV branches into the right portal vein (RPV) and the left portal vein (LPV). In type 2 (group 2), the MPV trifurcates into the right anterior portal vein (RAPV), right posterior portal vein (RPPV) and LPV. In type 3 (group 3), the RPPV arises from the MPV as a first branch, and the RAPV emerges directly from the LPV.

Results

No differences were observed between groups 1 and 2 with respect to ERLV ratios. However, significant differences were discovered between groups 1 and 3 and between groups 2 and 3 (p < 0.001 and p < 0.05, respectively).

Conclusions

The ERLV proportions in the donors with a type 3 MPV variation were significantly lower than those in the donors with type 1 and type 2 MPV variations and six (31.6%) donors in group 3 presented an ERLV percentage below 30% of the total liver volume.  相似文献   

20.

Objective

To investigate the accuracy of velocity measurements in patients with aortic valve stenosis using phase contrast (PC) imaging accelerated with SENSE (Sensitivity Encoding) and k-t BLAST (Broad-use Linear Acquisition Speed-up Technique).

Methods

Accelerated quantitative breath hold PC measurements, using SENSE and k-t BLAST, were performed in twelve patients whose aortic valve stenosis had been initially diagnosed using echocardiography. Stroke volume (SV) and peak velocity measurements were performed on each subject in three adjacent slices using both accelerating methods.

Results

The peak velocities measured with PC MRI using SENSE were −8.0 ± 9.5% lower (p < 0.01) compared to the peak velocities measured with k-t BLAST and the correlation was r = 0.83. The stroke volumes when using SENSE were slightly higher 0.4 ± 17.1 ml compared to the SV obtained using k-t BLAST but the difference was not significant (p > 0.05).

Conclusions

In this study higher peak velocities were measured in patients with aortic stenosis when combining k-t BLAST with PC MRI compared to PC MRI using SENSE. A probable explanation of this difference is the higher temporal resolution achieved in the k-t BLAST measurement. There was, however, no significant difference between calculated SV based on PC MRI using SENSE and k-t BLAST, respectively.  相似文献   